This is a Renovation Level NESHAP Asbestos Roof Survey report dated May 30, 2025, conducted at the VA Healthcare System facility located at 1201 NW 16th Street, Miami, FL 33125 under Prime Contract No. 36C24824D0026 and Project No. 546-24-129.

The survey was performed on May 14-15, 2025, by Mr. Stephen Crotty, an AHERA-accredited asbestos building inspector working under the direction of Steven A. Lipson, CIH, FLAC (Florida Licensed Asbestos Consultant #AX-43). NV5, Inc. holds Florida Asbestos Business License #ZA-419. A total of 92 bulk samples were collected from roof flashing, rolled asphalt roofing, pipe mastic flashing, and duct mastic flashing materials identified as potentially impacted by the planned roof replacement activities. Samples were analyzed by Eurofins Laboratories, Inc. (Fort Lauderdale, Florida) using Polarized Light Microscopy (PLM) in accordance with EPA Method 40 CFR Part 763, Sub-part F, Appendix A. The critical finding is that none of the sampled materials were found to contain asbestos concentrations greater than one percent. The report recommends that any unsampled, suspect asbestos-containing materials identified during renovation activities should be assumed to contain asbestos until sampling and analysis documents otherwise. An EPA-generated list of suspect asbestos-containing materials is provided as an attachment for reference during renovation work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

12467 Telecom Drive | Temple Terrace, FL 33637 | www.NV5.com | Office 813.571.9788 | Fax 813.571.9374

CONSTRUCTION QUALITY ASSURANCE - INFRASTRUCTURE - ENERGY - PROGRAM MANAGEMENT - ENVIRONMENTAL

May 30, 2025

NV5 Project #: 1830725-0005008.00

Spees LLC 23830 Pacific Hwy S, Suite 300 Kent, WA 98032 Attn: Edward A. McManamna, Senior Architect

Re: Renovation Level / NESHAP Asbestos Roof Survey Project: VA FL Miami B1 Roof

Project No.: 546-24-129 Prime Contract No.: 36C24824D0026 Project Location: VA Healthcare System 1201 NW 16th Street, Miami, FL 33125

Dear Mr. McManamna, A renovation level roof survey for asbestos-containing materials (ACMs) was performed at the above referenced facility on May 14, 2025 and May 15, 2025 by Mr. Stephen Crotty. Mr. Crotty is an AHERA accredited asbestos building inspector working under the direction of a Florida Licensed Asbestos Consultant (#AX-43). Collected samples were forwarded to Eurofins Laboratories, Inc. (Eurofins), an independent laboratory located in Fort Lauderdale, Florida, for analysis by Polarized Light Microscopy

(PLM).

Only those materials identified by the client as possibly being impacted by the planned roof replacement activities were sampled by NV5. Interior and exterior portions of the building were not included in the scope of this project.

None of the sampled materials were found to contain asbestos concentrations greater than one percent.

If any un-sampled, suspect asbestos-containing materials are identified during the course of renovation activities at the facility, these materials should be assumed to contain asbestos until and unless sampling and analysis documents otherwise. Please see the attachments of this report for an EPA generated list of suspect materials.

If you should have any questions regarding this information, please do not hesitate to contact our office at

(786) 564-2728.

Sincerely, NV5, Inc.

Florida Asbestos Business License #ZA-419

Steven A. Lipson, CIH, FLAC Asbestos Consultant #AX-43

P a g e | 2

TABLE OF CONTENTS

SECTION PAGE

1.0 Summary of Results 3

2.0 Recommendations 4

3.0 Facility Description 5

4.0 Sampling Methodology 6

5.0 Analytical Methodology 6

Appendices Analytical Laboratory Results Chains of Custody Licenses and Certifications Excerpt from U.S.E.P.A. Document 20 T-2003, July 1990 - “Sample List of Suspect Asbestos-Containing

Materials”

P a g e | 3

1.0 SUMMARY OF RESULTS

*HSA

Sample

Nos.

Sample Material - Location

PLM

Analysis

Quantity

ACM

**EPA

CAT

A Y1 – Y3 Roof Flashing NAD N/A N/A

B Y4 – Y6 Rolled Asphalt Roofing NAD N/A N/A

C Z1 – Z3 Rolled Asphalt Roofing NAD N/A N/A

D Z4 – Z6 Roof Flashing NAD N/A N/A

E AA1 – AA3 Roof Flashing NAD N/A N/A

F AA4 – AA6 Rolled Asphalt Roofing NAD N/A N/A

G AA7 Pipe Mastic Flashing NAD N/A N/A

H A1 – A3 Duct mastic Flashing

NAD N/A N/A

I A4 – A6 Roof Flashing

NAD N/A N/A

J A7 – A9 Rolled Asphalt Roofing

NAD N/A N/A

K I1 – I3 Rolled Asphalt Roofing

NAD N/A N/A

L I4 – I6 Roof Flashing

NAD N/A N/A

M I7 Duct Flashing

NAD N/A N/A

N J1 – J3 Rolled Asphalt Roofing

NAD N/A N/A

O L1 – L3 Rolled Asphalt Roofing

NAD N/A N/A

P L4 – L6 Roof Flashing

NAD N/A N/A

Q M1 – M3 Roof Flashing

NAD N/A N/A

R M4 – M6 Rolled Asphalt Roofing

NAD N/A N/A

S R1 – R3 Roof Flashing

NAD N/A N/A

T R4 – R6 Rolled Asphalt Roofing

NAD N/A N/A

U P1 – P3 Rolled Asphalt Roofing

NAD N/A N/A

V P4 – P6 Roof Flashing

NAD N/A N/A

W V1 – V3 Rolled Asphalt Roofing

NAD N/A N/A

X V4 – V6 Roof Flashing

NAD N/A N/A

P a g e | 4

*HSA

Sample

Nos.

Sample Material - Location

PLM

Analysis

Quantity

ACM

**EPA

CAT

Y G1 – G3 Rolled Asphalt Roofing

NAD N/A N/A

Z G4 – G6 Roof Flashing

NAD N/A N/A

AA B1 – B3 Roof Flashing

NAD N/A N/A

BB B4 – B6 Rolled Asphalt Roofing

NAD N/A N/A

CC C1 – C3 Roof Flashing

NAD N/A N/A

DD C4 – C6 Rolled Asphalt Roofing

NAD N/A N/A

EE D1 – D3 Rolled Asphalt Roofing

NAD N/A N/A

FF D4 – D6 Roof Flashing

NAD N/A N/A

TABLE LEGEND

*HSA: Homogeneous Sampling Area (like materials)

PLM Analysis: T = Tile M = Mastic VFS = Vinyl Floor Sheeting

Chry = Chrysotile Asbestos

Amo = Amosite Asbestos

Crd = Crocidolite Asbestos

NAD = No Asbestos Detected

** EPA Category: F = Friable

NF-I = Non Friable - Category I

NF-II = Non Friable - Category II

P a g e | 5

2.0 RECOMMENDATIONS

NV5 has no recommendations regarding the sampled materials at the site, at this time.

If any unsampled, suspect asbestos-containing materials are identified during the course of renovation or demolition activities at the site, these materials should either be sampled to determine possible asbestos concentrations or should be removed by a licensed contractor prior to being subjected to activities, which may disturb them.

P a g e | 6

3.0 FACILITY DESCRIPTION:

Current Use: VA Hospital Facility

Constructed: 1959/1980 and 2005

Size: Approximately 121,000 Square Feet

Foundation: Not Surveyed

Floors and Surfacing Not Surveyed

Interior Walls Construction: Not Surveyed

Interior Walls Surfacing: Not Surveyed

Ceiling and Surfacing: Not Surveyed

Exterior Walls Construction: Not Surveyed

Exterior Walls Surfacing: Not Surveyed

Roof: Rolled Asphalt with Flashing

HVAC: Flashing

P a g e | 7

4.0 SAMPLING METHODOLOGY

Bulk samples were collected by a method in which small amounts of materials are collected, placed into individual containers and sealed. A chain of custody is prepared, and the samples are forwarded to an independent, NVLAP accredited laboratory for analysis. Samples were collected by EPA and AHERA accredited building inspectors utilizing sterile procedures. Collected samples were placed into individual labeled polyethylene bags and sealed for transport to the laboratory. A chain of custody was prepared by the Inspector(s), and the samples were forwarded to an accredited laboratory for analysis (see below).

Sampling methods were implemented in an attempt to minimize asbestos fiber release during sampling. It was not within the scope of this survey to remove surface materials to observe portions of the structure or materials which lay beneath the surface. Any conditions or materials which were not visibly apparent on the surface were not surveyed. Unsampled suspect materials should be assumed to contain asbestos until documented otherwise.

Samples were collected in accordance with the following protocol: two samples were collected from each Homogeneous Sampling Area (HSA) of suspect EPA Category I and II non-friable material; three samples were collected from each Homogeneous Sampling Area (HSA) of suspect friable material; and surfacing materials and thermal systems insulation (TSI) were sampled in general accordance with the AHERA protocol. Materials were identified as suspect for asbestos content based upon the attached suspect materials list, generated by the United States Environmental Protection Agency.

The results, findings and conclusions expressed in this report are based only on the conditions which were observed during our survey of the accessible areas of the facility. This report makes no representation or assumptions as to past conditions or future occurrences. If any unsampled, suspect asbestos-containing materials are identified during the course of renovation activities these materials should be assumed to contain asbestos until and unless sampling and analysis document otherwise.

Materials visibly and completely identifiable as non-asbestos (metal, rubber, wood, etc.) were not sampled.

The selection of sample locations and frequency is based upon the project scope of services, the observations of the inspector, and the assumption that like materials in the same areas are homogeneous.

The quantities and locations of ACM listed in this report are approximations only. This report is not intended as a bidding document or as a removal specification.

5.0 ANALYTICAL METHODOLOGY

Collected samples were forwarded to Eurofins Built Environment Testing East, LLC of Fort Lauderdale, Florida for analysis by polarized light microscopy (PLM), coupled with dispersion staining analysis method USEPA 600/R-93/116. According to the laboratory, submitted samples were analyzed by PLM techniques in accordance with U.S. EPA Method 40 CFR Part 763, sub-part F, Appendix A, incorporating visual estimates of identified material percentages.

Eurofins is an independent laboratory which is NVLAP accredited to perform PLM analyses (NVLAP - # 200738-0).

Approved by:

Approved Signatory Orestes Mendez

Report for:

Stephen Crotty NV5, Inc.

14486 Commerce Way Miami Lakes, FL 33016

Regarding:

Eurofins Built Environment Testing East, LLC Project: 1830725-000.00; Asbestos Survey

EML ID: 4073081

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 05-15-2025

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S-1267) NVLAP Lab Code 200738-0

EMLab ID: 4073081, Page 1 of 15Eurofins Built Environment Testing East, LLC

Eurofins Built Environment Testing East, LLC 6340 NW 5th Way, Ft. Lauderdale, FL 33309

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Total Samples Submitted: 50 Total Samples Analyzed: 50

Total Samples with Layer Asbestos Content > 1%: 0

Location: Y-1, Roof Flashing Lab ID-Version‡: 20307422-1

Sample Layers Asbestos Content White Coating ND

Black Roof Flashing ND Sample Composite Homogeneity: Moderate

Location: Y-2, Roof Flashing Lab ID-Version‡: 20307423-1

Sample Layers Asbestos Content Silver Coating ND

Sample Composite Homogeneity: Good

Location: Y3, Roof Flashing Lab ID-Version‡: 20307424-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 3% Cellulose Sample Composite Homogeneity: Moderate

Location: Y4, Rolled Asphalt Roof Lab ID-Version‡: 20307425-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 2 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: Y5, Rolled Asphalt Roof Lab ID-Version‡: 20307426-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: Y6, Rolled Asphalt Roof Lab ID-Version‡: 20307427-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: Z1, Rolled Asphalt Roof Lab ID-Version‡: 20307428-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers 2% Cellulose

Sample Composite Homogeneity: Good

Location: Z2, Rolled Asphalt Roof Lab ID-Version‡: 20307429-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers 2% Cellulose

Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 3 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: Z3, Rolled Asphalt Roof Lab ID-Version‡: 20307430-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers 2% Cellulose

Sample Composite Homogeneity: Good

Location: Z4, Roof Flashing Lab ID-Version‡: 20307431-1

Sample Layers Asbestos Content Silver Coating ND

Sample Composite Homogeneity: Good

Location: Z5, Roof Flashing Lab ID-Version‡: 20307432-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: Z-6, Roof Flashing Lab ID-Version‡: 20307433-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 4073081, Page 4 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: AA-1, Roof Flashing Lab ID-Version‡: 20307434-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: AA-2, Roof Flashing Lab ID-Version‡: 20307435-1

Sample Layers Asbestos Content White Coating ND

Sample Composite Homogeneity: Good

Location: AA-3, Roof Flashing Lab ID-Version‡: 20307436-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: AA4, Rolled Asphalt Roofing Lab ID-Version‡: 20307437-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 5 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: AA5, Rolled Asphalt Roofing Lab ID-Version‡: 20307438-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: AA6, Rolled Asphalt Roofing Lab ID-Version‡: 20307439-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: AA-7, Pipe Mastic/Flashing Lab ID-Version‡: 20307440-1

Sample Layers Asbestos Content Gray Mastic ND

Sample Composite Homogeneity: Good

Location: A-1, Duct Mastic Flashing Lab ID-Version‡: 20307441-1

Sample Layers Asbestos Content Gray Mastic ND

Composite Non-Asbestos Content: 2% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 6 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: A-2, Duct Mastic Flashing Lab ID-Version‡: 20307442-1

Sample Layers Asbestos Content Gray Mastic ND

Sample Composite Homogeneity: Good

Location: A-3, Duct Mastic Flashing Lab ID-Version‡: 20307443-1

Sample Layers Asbestos Content Gray Mastic ND

Sample Composite Homogeneity: Good

Location: A-4, Roof Flashing Lab ID-Version‡: 20307444-1

Sample Layers Asbestos Content White Coating ND Gray Coating ND

Sample Composite Homogeneity: Good

Location: A-5, Roof Flashing Lab ID-Version‡: 20307445-1

Sample Layers Asbestos Content Gray Coating ND

Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 7 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: A-6, Roof Flashing Lab ID-Version‡: 20307446-1

Sample Layers Asbestos Content White Coating ND Gray Coating ND

Sample Composite Homogeneity: Good

Location: A-7, Rolled Asphalt Roofing Lab ID-Version‡: 20307447-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: A-8, Rolled Asphalt Roofing Lab ID-Version‡: 20307448-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: A-9, Rolled Asphalt Roofing Lab ID-Version‡: 20307449-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 8 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: I-1, Rolled Asphalt Roofing Lab ID-Version‡: 20307450-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers Sample Composite Homogeneity: Good

Location: I-2, Rolled Asphalt Roofing Lab ID-Version‡: 20307451-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Cellulose 3% Glass Fibers

Sample Composite Homogeneity: Good

Location: I-3, Rolled Asphalt Roofing Lab ID-Version‡: 20307452-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers Sample Composite Homogeneity: Good

Location: I-4, Roof Flashing Lab ID-Version‡: 20307453-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 3% Cellulose Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 9 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: I-5, Roof Flashing Lab ID-Version‡: 20307454-1

Sample Layers Asbestos Content Gray Coating ND

Sample Composite Homogeneity: Good

Location: I-6, Roof Flashing Lab ID-Version‡: 20307455-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: I-7, Duct Flashing Lab ID-Version‡: 20307456-1

Sample Layers Asbestos Content Gray Coating ND

Sample Composite Homogeneity: Good

Location: J-1, Rolled Asphalt Roof Lab ID-Version‡: 20307457-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 10 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: J-2, Rolled Asphalt Roof Lab ID-Version‡: 20307458-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers Sample Composite Homogeneity: Good

Location: J-3, Rolled Asphalt Roof Lab ID-Version‡: 20307459-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 3% Glass Fibers Sample Composite Homogeneity: Good

Location: L-1, Rolled Asphalt Roof Lab ID-Version‡: 20307460-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Cellulose 3% Glass Fibers

Sample Composite Homogeneity: Good

Location: L-2, Rolled Asphalt Roof Lab ID-Version‡: 20307461-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Cellulose 3% Glass Fibers

Sample Composite Homogeneity: Good

EMLab ID: 4073081, Page 11 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: L-3, Rolled Asphalt Roof Lab ID-Version‡: 20307462-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Cellulose 3% Glass Fibers

Sample Composite Homogeneity: Good

Location: L-4, Roof Flashing Lab ID-Version‡: 20307463-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 5% Glass Fibers 2% Cellulose

Sample Composite Homogeneity: Good

Location: L-5, Roof Flashing Lab ID-Version‡: 20307464-1

Sample Layers Asbestos Content Gray Coating ND

Sample Composite Homogeneity: Good

Location: L-6, Roof Flashing Lab ID-Version‡: 20307465-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 4073081, Page 12 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: M-1, Roof Flashing Lab ID-Version‡: 20307466-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 3% Glass Fibers 2% Cellulose

Sample Composite Homogeneity: Moderate

Location: M-2, Roof Flashing Lab ID-Version‡: 20307467-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 3% Glass Fibers 2% Cellulose

Sample Composite Homogeneity: Moderate

Location: M-3, Roof Flashing Lab ID-Version‡: 20307468-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 3% Glass Fibers 2% Cellulose

Sample Composite Homogeneity: Moderate

Location: M-4, Rolled Asphalt Roof Lab ID-Version‡: 20307469-1

Sample Layers Asbestos Content White Coating ND

Black Roofing Shingle ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 4073081, Page 13 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

Location: M-5, Rolled Asphalt Roof Lab ID-Version‡: 20307470-1

Sample Layers Asbestos Content White Coating ND

Black Roofing Shingle ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: M-6, Rolled Asphalt Roof Lab ID-Version‡: 20307471-1

Sample Layers Asbestos Content White Coating ND

Black Roofing Shingle ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 4073081, Page 14 of 15Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-14-2025 Date of Receipt: 05-15-2025 Date of Report: 05-15-2025

ASBESTOS PLM REPORT

PROJECT ANALYST AND SIGNATORY REPORT

Project Analyst

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Analyst: Orestes Mendez

EMLab ID: 4073081, Page 15 of 15Eurofins Built Environment Testing East, LLC

Approved by:

Approved Signatory Orestes Mendez

Report for:

Stephen Crotty NV5, Inc.

14486 Commerce Way Miami Lakes, FL 33016

Regarding:

Eurofins Built Environment Testing East, LLC Project: 1830725-000.00; Asbestos Survey

EML ID: 4074127

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 05-16-2025

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S-1267) NVLAP Lab Code 200738-0

EMLab ID: 4074127, Page 1 of 13Eurofins Built Environment Testing East, LLC

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-15-2025 Date of Receipt: 05-15-2025 Date of Report: 05-16-2025

ASBESTOS PLM REPORT

Total Samples Submitted: 42 Total Samples Analyzed: 42

Total Samples with Layer Asbestos Content > 1%: 0

Location: R-1, Roof Flashing Lab ID-Version‡: 20312723-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: R-2, Roof Flashing Lab ID-Version‡: 20312724-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: R-3, Roof Flashing Lab ID-Version‡: 20312725-1

Sample Layers Asbestos Content Silver Coating ND

Black Roof Flashing ND Composite Non-Asbestos Content: 2% Cellulose Sample Composite Homogeneity: Moderate

Location: R-4, Rolled Asphalt Roof Lab ID-Version‡: 20312726-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

EMLab ID: 4074127, Page 2 of 13Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-15-2025 Date of Receipt: 05-15-2025 Date of Report: 05-16-2025

ASBESTOS PLM REPORT

Location: R-5, Rolled Asphalt Roof Lab ID-Version‡: 20312727-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: R-6, Rolled Asphalt Roof Lab ID-Version‡: 20312728-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Glass Fibers Sample Composite Homogeneity: Good

Location: P-1, Rolled Asphalt Roof Lab ID-Version‡: 20312729-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Nylon Sample Composite Homogeneity: Good

Location: P-2, Rolled Asphalt Roof Lab ID-Version‡: 20312730-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Nylon Sample Composite Homogeneity: Good

EMLab ID: 4074127, Page 3 of 13Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/Built Client: NV5, Inc.

C/O: Stephen Crotty Re: 1830725-000.00; Asbestos Survey

Date of Sampling: 05-15-2025 Date of Receipt: 05-15-2025 Date of Report: 05-16-2025

ASBESTOS PLM REPORT

Location: P-3, Rolled Asphalt Roof Lab ID-Version‡: 20312731-1

Sample Layers Asbestos Content Black Roofing Shingle ND

Composite Non-Asbestos Content: 5% Nylon Sample Composite Homogeneity: Good

Location: P-4, Roof Flashing Lab ID-Version‡: 20312732-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 5% Nylon Sample Composite Homogeneity: Good

Location: P-5, Roof Flashing Lab ID-Version‡: 20312733-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 5% Nylon Sample Composite Homogeneity: Good

Location: P-6, Roof Flashing Lab ID-Version‡: 20312734-1

Sample Layers Asbestos Content Black Roof Flashing ND

Composite Non-Asbestos Content: 5% Nylon Sample Composite Homogeneity: Good

EMLab ID: 4074127, Page 4 of 13Eurofins Built Environment Testing East, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .