This document includes an overall site plan and related federal contract opportunity to correct physical security deficiencies at a Department of Veterans Affairs health care center. The site plan depicts existing conditions and proposed security upgrades at the Lee County VA Clinic in Cape Coral, Florida, including hardening site utility entrances, vehicle gates, perimeter fencing, and mailroom security. The related solicitation seeks providers to complete these security improvements within 232 calendar days, including installing cameras, lighting, fencing, barriers and other risk mitigation measures. Offerors must submit responses by the closing date to the Veterans Health Administration under Solicitation Number 36C24822R0136 to be considered for award.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VV

V

V

V

V

V

V

V

EASE

EASE

EASE

EASE

E

A

SE

EASE

EASE

11.2

EASE

EASE

S T O R M

S T O R M

T

T

S S

S S

S S

S S

S S

S T O R M

S T O R M

S T O R M

S

TO

R M

S

TO

R M

S T O R M

S T O R M

S T O R M

S T O R M

S T O R M

S T O R M

WET

RETENTION

POND, REFER TO

CIVIL DWGS.

DRY

RETENTION

POND, REFER TO

CIVIL DWGS.

FUTURE GATES,

REFER TO MEP

DWGS FOR STUB

OUT LOCATIONS

STAFF / SERVICE

SITE ENTRANCE

STAFF

ENTRY

URGENT

CARE

DRIVE

DRY RETENTION

POND, REFER

TO CIVIL DWGS.

FUTURE

EXPANSION

50 FT SECURITY

STANDOFF

ANTI-RAM

GATE,

REFER TO

M/A020

SERVICE YARD

SECURITY WALL,

REFER TO

D/A020, TYPICAL

FUTURE

EXPANSION

PUBLIC ENTRY

VISITOR

DROP-OFF

AREA

VISITOR PARKING

FUTURE

PARKING

WET

RETENTION

POND

VISITOR PARKING

WET

RETENTION

POND,

REFER TO

CIVIL DWGS.

MONUMENT

SIGN / WALL

FEATURE, REFER

TO A030

DRY

RETENTION

POND, REFER TO

CIVIL DWGS.

FUTURE

GATES,REFER TO

MEP DWGS FOR

STUB OUT

LOCATIONS

BUS

SHELTER,

REFER TO

B/A020

COMPACTOR

CARDBOARD

COMPACTOR

RAMP

RAMP

VENDOR VENDOR

CHAIN LINK

DOCK

LVLR

DOCK

LVLR

DRY

RETENTION

POND, REFER

TO CIVIL DWGS.

BUILDING AREA 222,926 GSF

FUTURE EXPANSION 60,000 GSF

TOTAL 282,926 GSF

PARKING DATA

STD ADA TOTAL

BASE BID 620 88 708

ADD ALTERNATE 230 10 240

TOTAL 850 98 948

FUTURE 260 0 260

PARKING RATIO

BASE BID =

708 SPACES / 222.9 (1000 SF) = 3.18 SPACES / 1000 SF

BASE BID + ADD ALTERNATE =

948 SPACES / 222.9 (1000 SF) = 4.25 SPACES / 1000 SF

BASE BID + ADD ALTERNATE + FUTURE =

1208 SPACES / 282.9 (1000 SF) = 4.27 SPACES / 1000 SF

FUTURE GUARD

HOUSE, REFER TO

MEP DWGS FOR

STUB OUT

LOCATIONS

ADD ALTERNATE #1 PARKING = 46SPACES,

REFER TO CIVIL DWGS.

ADD ALTERNATE #1 PARKING = 29

SPACES, REFER TO CIVIL DWGS.

BASE BID PARKING = 236 STD SPACES, 236 TOTAL SPACES

FUTURE PARKING = 182 SPACES

PUBLIC SITE ENTRY

SITE ENTRY SIGN, REFER TO A030

FUTURE GUARD HOUSE, REFER

TO MEP DWGS FOR STUB OUT

LOCATIONS

FUTURE PARKING = 78

SPACES, REFER TO CIVIL

DWGS.

BASE BID PARKING =

79 ADA SPACES

176 STD SPACES

255 TOTAL SPACES

EXISTING POND EXISTING POND

ADD ALTERNATE #1 PARKING =

10 ADA SPACES

9 STD SPACES

ADD ALTERNATE #1 PARKING = 146 SPACES

REFER TO CIVIL DRAWINGS

BASE BID PARKING

9 ADA SPACES

206 STD SPACES

215 TOTAL SPACES

A A002

6' HIGH SECURITY FENCE,

REFER TO C/A020

BUS

SHELTER,

REFER TO

B/A020

BUS

SHELTER,

REFER TO

B/A020

BUS

SHELTER,

REFER TO

B/A020

6' HIGH SECURITY FENCE,

REFER TO C/A020

SITE ENTRY SIGN, REFER TO A030

ANTI-RAM

HYDRAULIC

BOLLARDS, REFER

TO L/A020

GATE, REFER TO

N/A020

ANTI-RAM

BOLLARDS, REFER

TO J/A020

ANTI-RAM FENCING,

REFER TO F/A020

ANTI-RAM FENCING,

REFER TO F/A020

ANTI-RAM VEHICLE

BARRIER, REFER

TO E/A020

ANTI-RAM VEHICLE

BARRIER, REFER

TO E/A020

BUILDING DATA

HELLMUTH, OBATA & KASSABAUM, INC.

ARCHITECTURE, ENGINEERING, PLANNING,

INTERIORS, GRAPHICS, CONSULTING

Drawing Number:

Drawing Title: Project Number

DrawnChecked:

CONSULTANTS Project Title

Building Number

All reproduction & intellectual property rights reserved © 2009

Client Location

Contract No:

One Tampa City Center, Suite 1800, Tampa, FL, 33602 Voice:

Fax:

Internet:

| 813 | 229 - 0300 | 813 | 223 - 7116 http://www.hok.com

ARCHITECT/ ENGINEERS:

FL. Reg. AAC001139

Approved:

Date

Dwg. of

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9 on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

Department of Veterans Affairs

CONSTRUCTION DOCUMENTS (CD1)

FULLY SPRINKLERED

Revisions Date

Cape Coral, Florida

OVERALL SITE PLAN

A001

JK/JRAE AR/RT/CP

516CA2400

Lee County Outpatient Clinic

Office of Construction and Facilities Management

516CA2400

JK/JRAE

06/15/09

SITE PLAN

1"= 60'-0"

1 ADDENDUM 04 08/18/09

2 ASI #143 04/18/11

VHABAYStoneB Oval

VHABAYStoneB Text Box Staff Entry

VHABAYStoneB Line

VHABAYStoneB Oval

VHABAYStoneB Text Box Perimeter Access Screening

VHABAYStoneB Line

VHABAYStoneB Text Box Modify/Add fencing

VHABAYStoneB Line

VHABAYStoneB Line

VHABAYStoneB Line

VHABAYStoneB Text Box Replace existing VASS with new technology

VHABAYStoneB Oval

VHABAYStoneB Text Box Perimeter Access Screening/PACS

VHABAYStoneB Line

VHABAYStoneB Oval

VHABAYStoneB Line

VHABAYStoneB Text Box Add recommended risk mitigation measures.

File details come from the government source that posted it. Updated .