This site plan and related federal contract opportunity provide details for a construction project to correct physical security deficiencies at the Lee County Health Care Center in Cape Coral, Florida. The site plan drawing depicts the existing layout and proposed security upgrades, including hardening site utility entrances, vehicle gates, and the perimeter fence. Cameras and lighting will also be added for improved visibility. The federal contract opportunity is a solicitation from the Department of Veterans Affairs seeking bids to complete the work within 232 calendar days. Services required include all necessary equipment, labor, materials, specialty services, supervision, and tools to install the security upgrades illustrated in the site plan and make the mailroom compliant with the 2015 VA Physical Security Design Manual. The bidding period closes on the date specified in the solicitation number 36C24822R0136.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

V

V

V

T

UP

UP

WET RETENTION

POND, REFER TO

CIVIL DWGS

UNDERGROUND GENERATOR

FUEL STORAGE TANKS

FIRE WATER

STORAGE

TANK

SERVICE YARD

SCREEN/SECURITY

WALL, REFER TO D/A020

SINGLE LEAF

CANTILEVER

ANTI-RAM

GATE, REFER

TO M/A020

POWER CO.

EQUIPMENT

LIFE SAFETY

EXIT FROM

BUILDING

8'-0" HIGH WALL

LOADING # 1

LOADING # 2

F T

SE

C

U R

IT

Y

ST

AN

D O

FF

MOBILE IMAGING # 2 MOBILE IMAGING # 1

LOADING/RECEIVING,

MAILROOM

COOLING

TOWER

YARD

50 FT SECURITY STANDOFF

CENTRAL

ENERGY

PLANT

STAFF

ENTRY

URGENT

CARE

ENTRY

CANOPY

ABOVE

3'-0" HIGH WALL

CANOPY ABOVE

URGENT CARE

DRIVE, CONCRETE

PAVING

50 FT SECURITY STANDOFF

F

T

SE

C U

R

IT

Y

ST

AN

D

O

FF

FUTURE

EXPANSION

3'-0" HIGH WALL/

VEHICLE BARRIER,

REFER TO E/A020

FLAGPOLES,

REFER TO

LANDSCAPE

DWGS. TYPICAL

50 FT SECURITY STANDOFF

VISITOR

DROP-OFF

AREA

FUTURE SECURITY

SCREENING VESTIBULE

PUBLIC

ENTRY

CANOPY

ABOVE

ANTI-RAM

BOLLARDS

(75) BD-1,

TYPICAL,

REFER TO

J/A020

FUTURE EXPANSION

50 FT SECURITY STANDOFF

VEHICLE BARRIER, REFER TO

E/A020

EXISTING

RETENTION

POND

COMPACTOR (NIC)

CARDBOARD (NIC)

COMPACTOR

RAMP

RAMP

VENDOR

VENDOR

DOCK

LVLR

DOCK

LVLR

BUS

SHELTER

REFER TO

B/A020, TYPICAL

OUTDOOR DINING AREA

BENCH, REFER TO

LANDSCAPE DWGS

TYPICAL

ENTRY SIGN,

REFER TO

A030

TREE PLANTER,

REFER TO

LANDSCAPE

DWGS. TYPICAL

ADD ALTERNATE PERIMETER FENCE

VEHICLE BARRIER,

REFER TO E/A020

ANTI-RAM BOLLARDS

BD-1 (5), REFER TO

J/A020

ANTI-RAM CABLE

FENCE, REFER TO

F/A020

ANTI-RAM CABLE

FENCE, REFER TO

F/A020

TREE PLANTER,

REFER TO

LANDSCAPE

DWGS. TYPICAL

A011 A

A011 B

A010 A

SCREEN/SECURITY

WALL, REFER TO D/A020

FUTURE GATES,

REFER TO MEP FOR

STUB OUT LOCATIONS

SECURITY FENCE,

REFER TO C/A020

SECURITY FENCE,

REFER TO C/A020

PEDESTRIAN ACCESS

AT ANTI-RAM CABLE

FENCE, REFER TO

H/A020

DECORATIVE

BOLLARDS (54) BD-2,

TYPICAL, REFER TO

K/A020

DOUBLE

CANTILEVER

SECURITY

GATE, REFER

TO N/A020

ANTI-RAM

HYDRAULIC

BOLLARDS BD-3 (8)

REFER TO L/A020

CONCRETE PAVING

E

A020

TYP.

D

A020

TYP.

D

A020

TYP.

E

A020

TYP.

SCREEN

WALL, REFER

TO D1/A020

CLEAR

24' - 0"

CL

EA

R

0"

67' - 0"

219' - 1"

.98

110.02°

135.00°

135.00°

0"

UNDERGROUND

POTABLE

WATER TANK

BULK OXYGEN

SYSTEM YARD

UNDERGROUND

IRRIGATION CISTERN

123' - 11"

81' - 8 1/2"

7 1 /2"

0"

0"

SCREEN

WALL,

REFER TO

D1/A020

LIFT STATION &

UNDERGROUND

STORAGE TANKS

SCREEN/SECURITY

WALL, REFER TO D/A020

D1

A020

TYP.

WELL LOCATION -

INSTALLED

VEHICLE ACCESS

REQUIRED FOR WELL

26' - 0"

37' - 6 1/2"

REMOVABLE ANTI-

RAM BOLLARDS

20' - 0"

BICYCLE RACKS

SMOKING SHELTER

& CONCRETE

SIDEWALK BICYCLE RACKS

SMOKING SHELTER

& CONCRETE

SIDEWALK

4'

- 2

0"

HELLMUTH, OBATA & KASSABAUM, INC.

ARCHITECTURE, ENGINEERING, PLANNING,

INTERIORS, GRAPHICS, CONSULTING

Drawing Number:

Drawing Title: Project Number

DrawnChecked:

CONSULTANTS Project Title

Building Number

All reproduction & intellectual property rights reserved © 2008

Client Location

Contract No:

One Tampa City Center, Suite 1800, Tampa, FL, 33602 Voice:

Fax:

Internet:

| 813 | 229 - 0300 | 813 | 223 - 7116 http://www.hok.com

ARCHITECT/ ENGINEERS:

FL. Reg. AAC001139

Approved:

Date

Dwg. of

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9 on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

Department of Veterans Affairs

CONSTRUCTION DOCUMENTS (CD1)

FULLY SPRINKLERED

Revisions Date

Cape Coral, Florida

BUILDING SITE PLAN

A002

JK/JRAE AR/RT

516CA2400

Lee County Outpatient Clinic

Office of Construction and Facilities Management

516CA2400

JK/JRAE

06/15/09

1" = 30'-0"A BUILDING SITE PLAN

1 ADDENDUM 04 08/18/09

2 ASI #103 02/21/11

3 ASI #116 03/06/11

4 ASI #116.1 3/15/11

5 ASI #136 04/05/11

File details come from the government source that posted it. Updated .