36C24818R0238-00002000.docx
DOCX document 20 KB Posted
- Attached to
- Design and replace the three (3) existing air-cooled chillers at Viera Out Patient Clinic (OPC)
- Solicitation number
- 36C24818R0238
About this file
36C24818R0238 00002 36C24818R0238 00002.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24818R0238-00002002.pdf | ||
| 36C24818R0238-00002001.pdf | ||
| 36C24818R0238-00002004.pdf | ||
| 36C24818R0238-00002003.pdf | ||
| 36C24818R0238-00001001.pdf | ||
| 36C24818R0238-00001002.pdf | ||
| 36C24818R0238-00001000.docx | DOCX document | |
| 36C24818R0238-001.docx | DOCX document | |
| 36C24818R0238-002.pdf | ||
| 36C24818R0238-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE
OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
BY
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 00002 04-11-2018 675-18-151 36C248 Department of Veterans Affairs Network Contracting Office 8 (NCO 8) for Orlando VA 8875 Hidden River Pkwy Suite 525 Tampa
FL
33637 36C248 Department of Veterans Affairs Network Contracting Office 8 (NCO 8) for Orlando VA 8875 Hidden River Pkwy Tampa
FL
33637 To all Offerors/Bidders
36C24818R0238 03-15-2018
X X X
The purpose of this amendment is to incorporate Request for Information (RFI) Set #2 and to incorporate drawings that were inadvertently left out of Amendment 00001.
See continuation pages for details
Tiffany Garfield Design Build Replace Chillers at Viera 36C24818R0238 Request For Information Set #2 April 11, 2018
1. Original Solicitation page 19 of 99, item 21, states “Replacement of existing BAS system to BACnet is an option to ease in multi-system integration”. Does this statement mean that the existing Trane BAS control system does not have to continue to be used and that control systems of other manufacturers are allowed to be installed for overall BAS control of the facility if the change will allow a more competitive price?
VA: Yes, BACnet system.
2. Original Solicitation page 19 of 99, item 10, states “Demolish the existing CMU block screen wall and build a mechanical building with approximately 4400 SF floor area with all required utilities for the three new water-cooled chillers and associated equipment”. Instead of a new building, will new outdoor modular package unit water cooled chillers that do not require a new building be acceptable? In other words, can we place new package water cooled chillers outside without a new building? The proposed outdoor units do have their own immediate packaged enclosure. The cooling towers would be outside of a building regardless.
VA: Modular not acceptable.
3. There is only about 4400 SF of space available in the existing chiller yard area. With cooling towers being outside the new building footprint (since they are outdoor units) and only 4400 SF of space available, the outdoor cooling towers would reduce the 4400 SF available area by about 1000-1200 SF to 3200 SF. Is the 4400 SF requirement allocated for chillers and the cooling towers combined making the resulting building somewhat smaller (since cooling towers are outside the building footprint)? If a building is required, is 4400 SF necessary if we can satisfy all requirements in a smaller building?
VA: The proposed layout is 4400 SF building and cooling towers will be located at back (existing parking lot). This is just a proposed layout, this is a design build project.
4. Can the VA provide historical electrical demand load data on the existing facility emergency power system?
VA: This may be provided after Phase 1.
5. Can the VA provide historical electrical demand load data on the existing normal power utility services to the facility?
6. To meet N+1 redundancy, will the contractor be required to provide a minimum of (2) new emergency generators
VA: May be. Again this is a design build project.
7. Apart from utility transformers, are there any components within the existing chiller yard or associated electrical systems that are owned by FP&L?
8. Does the VA own the two 480V oil-filled utility transformers feeding the facility and the chiller plant? Are these transformers and their associated primaries owned by the utility company?
9. Upon loss of normal power at the facility, do existing non-emergency chilled water valves fail in the closed or open position
10. What are the redundancy requirements for any temporary systems used during this project?
VA: Please refer to references provided in the solicitation.
11. What are the chiller redundancy requirements upon loss of normal power?
12. Will the new chiller enclosure building require fire sprinklers and fire alarm?
13. Standard master VA specifications limit automatic transfer switch (ATS) size to 800A maximum. Will the VA permit a larger ATS for this project (as a variance to the master VA specifications)?
VA: Design shall be in compliant of VA Master specifications.
14. Will Phase 1 proposals be kept confidential for the entire duration of the proposal and bid process? In other words, will any non-VA personnel be able to view Phase 1 proposals prior to award of contract?
VA: all proposals are kept within the source selection team for the duration. This is government personnel only.
See attached document: Attachment RFI 1 _ 2 RTU and Chillers Viera 1.
See attached document: Attachment RFI 1 _ 2 RTU and Chillers Viera 2.
See attached document: Attachment RFI 1 _ 2 RTU and Chillers Viera 4.
See attached document: Attachment RFI 1 _ 2 RTU and Chillers Viera 3.
File details come from the government source that posted it.