36C24818Q0741-006.xlsx
XLSX spreadsheet 152 KB Posted
- Attached to
- Services, Circuit Breaker Testing Federal contract opportunity
- Solicitation number
- 36C24818Q0741
About this file
36C24818Q0741 Attachment E Pricing Assistance Worksheet and all data.xlsx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24818Q0741-012.docx | DOCX document | |
| 36C24818Q0741-010.docx | DOCX document | |
| 36C24818Q0741-011.pdf | ||
| 36C24818Q0741-005.pdf | ||
| 36C24818Q0741-004.pdf | ||
| 36C24818Q0741-000.docx | DOCX document | |
| 36C24818Q0741-008.pdf | ||
| 36C24818Q0741-002.pdf | ||
| 36C24818Q0741-007.pdf | ||
| 36C24818Q0741-001.pdf | ||
| 36C24818Q0741-009.pdf | ||
| 36C24818Q0741-003.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pricing Assistance Worksheet
| Item Number | Description of Services | Best Estimated Quantity | Unit | Unit Price | Total Amount |
| _0001 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| _0001AA | Building 100, ELINS A001 through A446 | 446 | JB | $ - 0 | |
| _0001AB | Building 106, ELINS B001 through B033 | 33 | JB | $ - 0 | |
| _0001AC | Building 300, ELINS C001 through C003 | 3 | JB | $ - 0 | |
| _0001AD | Building 107, ELINS D001 through D021 | 21 | JB | $ - 0 | |
| _0001AE | Building 109, ELINS E001 through E004 | 4 | JB | $ - 0 | |
| _0001AF | Building 22, ELINS F001 through F042 | 42 | JB | $ - 0 | |
| _0001AG | Building 20, ELIN G001 through G017 | 17 | JB | $ - 0 | |
| _0001AH | Building 103, ELIN H001 | 1 | JB | $ - 0 | |
| _0001AJ | Building 1, ELINS J001 through J092 | 92 | JB | $ - 0 | |
| _0001AK | Buildings 23 and 40, ELINS K001 through K037 | 37 | JB | $ - 0 | |
| _0001AL | Building 24, ELINS L001 through L021 | 21 | JB | $ - 0 | |
| _0001AM | Building 12, 13, 17, 19 and 45, ELINS M001 through M047 | 47 | JB | $ - 0 | |
| _0001AN | Building 102, ELINS N001 though N061 | 61 | JB | $ - 0 | |
| _0001AP | Building 71 and 101, ELINS P001 through P063 | 63 | JB | $ - 0 | |
| _0001AQ | Building 37, ELINS Q001 through Q057 | 57 | JB | $ - 0 | |
| _0001AR | Building 36, ELINS R001 through R007 | 7 | JB | $ - 0 | |
| _0001AS | Building 11 and 54, ELINS S001 through S019 | 19 | JB | $ - 0 | |
| _0001AT | Building 2, ELINS T001 through T052 | 52 | JB | $ - 0 | |
| _0001AU | Building 111, ELINS U001 through U026 | 26 | JB | $ - 0 | |
| _0002 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| _0002AA | Transformers, Attachment B, ELIN(s) A001 -A031 | 31 | JB | $ - 0 | |
| _0003 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| _0003AA | Protective Relays, Attachment C, ELIN(s) A001 through A006 | 71 | JB | $ - 0 | |
| _0004 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| _0004AA | Building 111, ELINS U001 through U026 | 26 | JB | $ - 0 | |
| 1005 | EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start. | 12 | Months | $0.00 | $0.00 |
| TOTAL | $0.00 | ||||
| OPTION YEAR ONE | |||||
| 1001 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 1001AA | Building 100, ELINS A001 through A446 | 446 | JB | $ - 0 | |
| 1001AB | Building 106, ELINS B001 through B033 | 33 | JB | $ - 0 | |
| 1001AC | Building 300, ELINS C001 through C003 | 3 | JB | $ - 0 | |
| 1001AD | Building 107, ELINS D001 through D021 | 21 | JB | $ - 0 | |
| 1001AE | Building 109, ELINS E001 through E004 | 4 | JB | $ - 0 | |
| 1001AF | Building 22, ELINS F001 through F042 | 42 | JB | $ - 0 | |
| 1001AG | Building 20, ELIN G001 through G017 | 17 | JB | $ - 0 | |
| 1001AH | Building 103, ELIN H001 | 1 | JB | $ - 0 | |
| 1001AJ | Building 1, ELINS J001 through J092 | 92 | JB | $ - 0 | |
| 1001AK | Buildings 23 and 40, ELINS K001 through K037 | 37 | JB | $ - 0 | |
| 1001AL | Building 24, ELINS L001 through L021 | 21 | JB | $ - 0 | |
| 1001AM | Building 12, 13, 17, 19 and 45, ELINS M001 through M047 | 47 | JB | $ - 0 | |
| 1001AN | Building 102, ELINS N001 though N061 | 61 | JB | $ - 0 | |
| 1001AP | Building 71 and 101, ELINS P001 through P063 | 63 | JB | $ - 0 | |
| 1001AQ | Building 37, ELINS Q001 through Q057 | 57 | JB | $ - 0 | |
| 1001AR | Building 36, ELINS R001 through R007 | 7 | JB | $ - 0 | |
| 1001AS | Building 11 and 54, ELINS S001 through S019 | 19 | JB | $ - 0 | |
| 1001AT | Building 2, ELINS T001 through T052 | 52 | JB | $ - 0 | |
| 1001AU | Building 111, ELINS U001 through U026 | 26 | JB | $ - 0 | |
| 1002 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 1002AA | Transformers, Attachment B, ELIN(s) A001 -A031 | 31 | JB | $ - 0 | |
| 1003 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 1003AA | Protective Relays, Attachment C, ELIN(s) A001 through A006 | 71 | JB | $ - 0 | |
| 1004 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 1004AA | Building 12, 13, 17, 19 and 45, ELINS M001 through M047 | 47 | JB | $ - 0 | |
| 1004AB | Building 11 and 54, ELINS S001 through S019 | 19 | JB | $ - 0 | |
| 1004AC | Building 103, ELIN H001 | 1 | JB | $ - 0 | |
| 1004AD | Building 300 ELINS C001 through C003 | 3 | JB | $ - 0 | |
| 1004AE | Building 37, ELINS Q001 through Q057 | 57 | JB | $ - 0 | |
| 1004AF | Building 102, ELINS N001 though N061 | 61 | JB | $ - 0 | |
| 1004AG | Building 20, ELIN G001 through G017 | 17 | JB | $ - 0 | |
| 1004AH | Building 71 and 101, ELINS P001 through P063 | 63 | JB | $ - 0 | |
| 1004AJ | Building 2, ELINS T001 through T052 | 52 | JB | $ - 0 | |
| 1004AK | Building 107 ELINS D001 through D021 | 21 | JB | $ - 0 | |
| 1004AL | Building 36 ELINS R001 through R007 | 7 | JB | $ - 0 | |
| 1005 | EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start. | 12 | Months | $0.00 | $0.00 |
| TOTAL | $ - 0 | ||||
| OPTION YEAR TWO | |||||
| 2001 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 2001AA | Building 100, ELINS A001 through A446 | 446 | JB | $ - 0 | |
| 2001AB | Building 106, ELINS B001 through B033 | 33 | JB | $ - 0 | |
| 2001AC | Building 300, ELINS C001 through C003 | 3 | JB | $ - 0 | |
| 2001AD | Building 107, ELINS D001 through D021 | 21 | JB | $ - 0 | |
| 2001AE | Building 109, ELINS E001 through E004 | 4 | JB | $ - 0 | |
| 2001AF | Building 22, ELINS F001 through F042 | 42 | JB | $ - 0 | |
| 2001AG | Building 20, ELIN G001 through G017 | 17 | JB | $ - 0 | |
| 2001AH | Building 103, ELIN H001 | 1 | JB | $ - 0 | |
| 2001AJ | Building 1, ELINS J001 through J092 | 92 | JB | $ - 0 | |
| 2001AK | Buildings 23 and 40, ELINS K001 through K037 | 37 | JB | $ - 0 | |
| 2001AL | Building 24, ELINS L001 through L021 | 21 | JB | $ - 0 | |
| 2001AM | Building 12, 13, 17, 19 and 45, ELINS M001 through M047 | 47 | JB | $ - 0 | |
| 2001AN | Building 102, ELINS N001 though N061 | 61 | JB | $ - 0 | |
| 2001AP | Building 71 and 101, ELINS P001 through P063 | 63 | JB | $ - 0 | |
| 2001AQ | Building 37, ELINS Q001 through Q057 | 57 | JB | $ - 0 | |
| 2001AR | Building 36, ELINS R001 through R007 | 7 | JB | $ - 0 | |
| 2001AS | Building 11 and 54, ELINS S001 through S019 | 19 | JB | $ - 0 | |
| 2001AT | Building 2, ELINS T001 through T052 | 52 | JB | $ - 0 | |
| 2001AU | Building 111, ELINS U001 through U026 | 26 | JB | $ - 0 | |
| 2002 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 2002AA | Transformers, Attachment B, ELIN(s) A001 -A031 | 31 | JB | $ - 0 | |
| 2003 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 2003AA | Protective Relays, Attachment C, ELIN(s) A001 through A006 | 71 | JB | $ - 0 | |
| 2004 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 2004AA | Building 100, ELINS A001 through A446 | 446 | JB | $ - 0 | |
| 2004AB | Building 106, ELINS B001 through B033 | 33 | JB | $ - 0 | |
| 2004AC | Building 109, ELINS E001 through E004 | 4 | JB | $ - 0 | |
| 2005 | EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start. | 12 | Months | $0.00 | $0.00 |
| TOTAL | $ - 0 | ||||
| OPTION YEAR THREE | |||||
| 3001 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 3001AA | Building 100, ELINS A001 through A446 | 446 | JB | $ - 0 | |
| 3001AB | Building 106, ELINS B001 through B033 | 33 | JB | $ - 0 | |
| 3001AC | Building 300, ELINS C001 through C003 | 3 | JB | $ - 0 | |
| 3001AD | Building 107, ELINS D001 through D021 | 21 | JB | $ - 0 | |
| 3001AE | Building 109, ELINS E001 through E004 | 4 | JB | $ - 0 | |
| 3001AF | Building 22, ELINS F001 through F042 | 42 | JB | $ - 0 | |
| 3001AG | Building 20, ELIN G001 through G017 | 17 | JB | $ - 0 | |
| 3001AH | Building 103, ELIN H001 | 1 | JB | $ - 0 | |
| 3001AJ | Building 1, ELINS J001 through J092 | 92 | JB | $ - 0 | |
| 3001AK | Buildings 23 and 40, ELINS K001 through K037 | 37 | JB | $ - 0 | |
| 3001AL | Building 24, ELINS L001 through L021 | 21 | JB | $ - 0 | |
| 3001AM | Building 12, 13, 17, 19 and 45, ELINS M001 through M047 | 47 | JB | $ - 0 | |
| 3001AN | Building 102, ELINS N001 though N061 | 61 | JB | $ - 0 | |
| 3001AP | Building 71 and 101, ELINS P001 through P063 | 63 | JB | $ - 0 | |
| 3001AQ | Building 37, ELINS Q001 through Q057 | 57 | JB | $ - 0 | |
| 3001AR | Building 36, ELINS R001 through R007 | 7 | JB | $ - 0 | |
| 3001AS | Building 11 and 54, ELINS S001 through S019 | 19 | JB | $ - 0 | |
| 3001AT | Building 2, ELINS T001 through T052 | 52 | JB | $ - 0 | |
| 3001AU | Building 111, ELINS U001 through U026 | 26 | JB | $ - 0 | |
| 3002 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 3002AA | Transformers, Attachment B, ELIN(s) A001 -A031 | 31 | JB | $ - 0 | |
| 3003 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 3003AA | Protective Relays, Attachment C, ELIN(s) A001 through A006 | 71 | JB | $ - 0 | |
| 3004 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 3004AA | Building 1, ELINS J001 through J092 | 92 | JB | $ - 0 | |
| 3004AB | Buildings 23 and 40, ELINS K001 through K037 | 37 | JB | $ - 0 | |
| 3004AC | Building 22, ELINS F001 through F042 | 42 | JB | $ - 0 | |
| 3004AD | Building 24, ELINS L001 through L021 | 21 | JB | $ - 0 | |
| 3004AE | Building 111, ELINS U001 through U026 | 26 | JB | $ - 0 | |
| 3005 | EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start. | 12 | Months | $0.00 | $0.00 |
| TOTAL | $ - 0 | ||||
| OPTION YEAR FOUR | |||||
| 4001 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 4001AA | Building 100 ELINS A001 through A446 | 446 | JB | $ - 0 | |
| 4001AB | Building 106 ELINS B001 through B033 | 33 | JB | $ - 0 | |
| 4001AC | Building 300 ELINS C001 through C003 | 3 | JB | $ - 0 | |
| 4001AD | Building 107 ELINS D001 through D021 | 21 | JB | $ - 0 | |
| 4001AE | Building 109, ELINS E001 through E004 | 4 | JB | $ - 0 | |
| 4001AF | Building 22, ELINS F001 through F042 | 42 | JB | $ - 0 | |
| 4001AG | Building 20, ELIN G001 through G017 | 17 | JB | $ - 0 | |
| 4001AH | Building 103, ELIN H001 | 1 | JB | $ - 0 | |
| 4001AJ | Building 1, ELINS J001 through J092 | 92 | JB | $ - 0 | |
| 4001AK | Buildings 23 and 40, ELINS K001 through K037 | 37 | JB | $ - 0 | |
| 4001AL | Building 24, ELINS L001 through L021 | 21 | JB | $ - 0 | |
| 4001AM | Building 12, 13, 17, 19 and 45, ELINS M001 through M047 | 47 | JB | $ - 0 | |
| 4001AN | Building 102, ELINS N001 though N061 | 61 | JB | $ - 0 | |
| 4001AP | Building 71 and 101, ELINS P001 through P063 | 63 | JB | $ - 0 | |
| 4001AQ | Building 37, ELINS Q001 through Q057 | 57 | JB | $ - 0 | |
| 4001AR | Building 36, ELINS R001 through R007 | 7 | JB | $ - 0 | |
| 4001AS | Building 11 and 54, ELINS S001 through S019 | 19 | JB | $ - 0 | |
| 4001AT | Building 2, ELINS T001 through T052 | 52 | JB | $ - 0 | |
| 4001AU | Building 111, ELINS U001 through U026 | 26 | JB | $ - 0 | |
| 4002 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 4002AA | Transformers, Attachment B, ELIN(s) A001 -A031 | 31 | JB | $ - 0 | |
| 4003 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below. | NSP | NSP | NSP | NSP |
| 4003AA | Protective Relays, Attachment C, ELIN(s) A001 through A006 | 71 | JB | $ - 0 | |
| 4004 | Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below. | NSP | NSP | NSP | NSP |
| 4004AA | Building 12, 13, 17, 19 and 45, ELINS M001 through M047 | 47 | JB | $ - 0 | |
| 4004AB | Building 11 and 54, ELINS S001 through S019 | 19 | JB | $ - 0 | |
| 4004AC | Building 103, ELIN H001 | 1 | JB | $ - 0 | |
| 4004AD | Building 300 ELINS C001 through C003 | 3 | JB | $ - 0 | |
| 4004AE | Building 37, ELINS Q001 through Q057 | 57 | JB | $ - 0 | |
| 4004AF | Building 102, ELINS N001 though N061 | 61 | JB | $ - 0 | |
| 4004AG | Building 20, ELIN G001 through G017 | 17 | JB | $ - 0 | |
| 4004AH | Building 71 and 101, ELINS P001 through P063 | 63 | JB | $ - 0 | |
| 4004AJ | Building 2, ELINS T001 through T052 | 52 | JB | $ - 0 | |
| 4004AK | Building 107 ELINS D001 through D021 | 21 | JB | $ - 0 | |
| 1004AL | Building 36 ELINS R001 through R007 | 7 | JB | $ - 0 | |
| 4005 | EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start. | 12 | Months | $0.00 | $0.00 |
| TOTAL | $ - 0 | ||||
| GRAND TOTAL | $ - 0 |
Transformers
| ELIN | Transformer Location | Name |
| A001 | BLDG. 1 | T-1 |
| A002 | BLDG. 2 | T-2 |
| A003 | BLDG. 11 | T-11 |
| A004 | BLDG. 13 | T-13 |
| A005 | BLDG. 20 | T-20 |
| A006 | BLDG. 22 | T-22 |
| A007 | BLDG. 23 | T-23 |
| A008 | BLDG. 24 | T-24 |
| A009 | BLDG. 36 | T-36 |
| A010 | BLDG. 37 | T-37 |
| A011 | BLDG. 56 | T-56 |
| A012 | BLDG. 71 | T-71 |
| A013 | BLDG. 100 | USNE |
| A014 | BLDG. 100 | USNW |
| A015 | BLDG. 100 | USEE |
| A016 | BLDG. 100 | USEW |
| A017 | BLDG. 100 | USPB |
| A018 | BLDG. 100 | USPA |
| A019 | BLDG. 100 | NDP |
| A020 | BLDG. 100 | MHMECH-1 |
| A021 | BLDG. 100 | MHMECH-2 |
| A022 | BLDG. 101 | T-101 |
| A023 | BLDG. 102 | T-102 |
| A024 | BLDG. 111 | MHN-1 |
| A025 | BLDG. 111 | MHN-2 |
| A026 | BLDG. 203 | T-203 |
| A027 | BLDG. 106 | T-106 |
| A028 | BLDG. 107 | T-107 |
| A029 | BLDG. 109 | T-109 |
| A030 | BLDG. 1001 | T-1001 |
| A031 | REC INVERTER | REC INVERTER |
Attachment B
TRANSFORMER OIL TESTING
Protective Relays
| ELIN | Location | Room | Relay | Manufacturer | Type | Number of Relays |
| A001 | Building 100 | 1F116 | Reverse Power Relays | Westinghouse | Type CW | 5 |
| A002 | Building 100 | 1F115 | Directional Overcurrent | Westinghouse | Type CRP-2 | 2 |
| A003 | Building 100 | 1F115 | Overcurrent Relays | Westinghouse | Type CR-2 | 6 |
| A004 | Building 100 | 1F115 | Overcurrent Relays | Westinghouse | Type CO-11 | 42 |
| A005 | Building 100 | 1F115 | Ground Overcurrent | Westinghouse | Type ITH | 14 |
| A006 | Building 100 | 1F115 | Ground Overcurrent | Westinghouse | Type CP | 2 |
Attachment C
CALIBRATE PROTECTIVE RELAYS IN
BUILDING 100
B-100
| ELIN | 1. SUB-STATIONS | |
| SUB-STATIONS | SIZE KVA | |
| A001 | Normal (DE) Sub-Station US-N+ | 2000 KVA |
| A002 | Normal (DE) Sub-Station US-N+ | 2000 KVA |
| A003 | Emergency (DE) Substation US-E+ | 2000 KVA |
| A004 | Emergency (DE) Substation US-E+ | 2000 KVA |
| A005 | Power Substation US-PA+ | 2000 KVA |
| A006 | Power Substation US-PB+ | 2000 KVA |
| A007 | Power Substation Life Safety | |
| A008 | Power Substation Equipment | |
| A009 | Power Substation Critical | |
| A010 | Power Substation Chiller (NPD) (EPD) | 3750 KVA |
| A011 | ASCO Paralleling Switchgear |
| 2. GENERATORS | |||
| BREAKER | SIZE | SUB-STATION | |
| A012 | GEN #1 | 1200 A | EMERGENCY |
| A013 | GEN #2 | 1200 A | EMERGENCY |
| A014 | GEN #3 | 1200 A | EMERGENCY |
| A015 | GEN #4 | 1200 A | EMERGENCY |
| A016 | GEN #5 | 1200 A | EMERGENCY |
| A017 | ATS #5 | 800 A | EMERGENCY |
| A018 | ATS #2A, 2B, 2C, 2D | 800 A | EMERGENCY |
| A019 | ATS #6 | 800 A | EMERGENCY |
| A020 | ATS #3A, 3B, 3C, 3D | 800 A | EMERGENCY |
| A021 | ATS #4A, 4B, 4C | 800 A | EMERGENCY |
| A022 | ATS #1 | 800 A | EMERGENCY |
| A023 | ATS #8 | 800 A | EMERGENCY |
| A024 | ATS #7 | 800 A | EMERGENCY |
| A025 | ATS #9 | 800 A | EMERGENCY |
| A026 | ATS #10 | 800 A | EMERGENCY |
| A027 | ATS #11 | 1000 A | US - PA |
| 3. SWITCHGEAR ROOM | |||
| BREAKER | SIZE | SUB-STATION | |
| A028 | MAIN | 3000 A | US-E |
| A029 | ATS #3A, 3B, 3C, 3D | 800 A | US-E |
| A030 | ATS #4A, 4B, 4C, | 800 A | US-E |
| A031 | ATS #8 | 800 A | US-E |
| A032 | TIE-BREAKER | 3000 A | US-E |
| A033 | MAIN | 3000 A | US-E |
| A034 | ATS #1 | 800 A | US-E |
| A035 | ATS #2A, 2B, 2C, 2D | 800 A | US-E |
| A036 | ATS #10 | 800 A | US-E |
| A037 | ATS #6 | 800 A | US-E |
| A038 | ATS #7 | 1200 A | US-E |
| A039 | X-RAY | 600 A | DS-C |
| A040 | S.B. 1,2,3 | 600 A | DS-C |
| A041 | S.B. 7-10 | 400 A | DS-C |
| A042 | EMERGENCY CHILLER #5 | 350 A | DS-P |
| A043 | EMERGENCY CHILLER #6 | 350 A | DS-P |
| A044 | SB1-3 | 350 A | DS-P |
| A045 | MCC-PE | 350 A | DS-Q |
| A046 | S.B. 7-10 | 300 A | DS-Q |
| A047 | S.B. 4-6 | 600 A | DS-L |
| A048 | IL-LHL | 200 A | DS-L |
| A049 | S.B. 7-10 | 200 A | DS-L |
| A050 | S.B. 1,2,3 | 400 A | DS-L |
| A051 | S.B. 4,5,6 | 400 A | DS-L |
| A052 | MAIN | 3000 A | US-N |
| A053 | S.B. 4,5,6 | 2000 A | US-N |
| A054 | S.B. 7-10 | 800 A | US-N |
| A055 | MCC-N | 600 A | US-N |
| A056 | MAIN | 3000 A | US-N |
| A057 | S.B. 1,2,3 | 2000 A | US-N |
| A058 | X-RAY | 600 A | US-N |
| A059 | ATS #9 | 800 A | US-N |
| A060 | TIE-BREAKER | 3000 A | US-N |
| A061 | CCU-1 | 1000 A | US-PA |
| A062 | MCC-PN-A | 600 A | US-PA |
| A063 | CCU-2 | 1000 A | US-PA |
| A064 | CCU-4 | 1000 A | US-PB |
| A065 | MCC-PN-B | 600 A | US-PB |
| A066 | CCU-3 | 1000 A | US-PB |
| A067 | ATS #5 | 800 A | US-PB |
| NEW CEP SwitchGear Room 1F-132 | ||||
| BREAKER | SIZE | Sub-Station | ||
| A068 | MAIN | MAIN | 4000 A | MHMECH-1 |
| A069 | CH-3 | CH-3 | 2000 A | MHMECH-1 |
| A070 | CH-4 | CH-4 | 2000 A | MHMECH-1 |
| A071 | CWP-1 | CWP-1 | 300 A | MHMECH-1 |
| A072 | CWP-2 | CWP-2 | 300 A | MHMECH-1 |
| A073 | CT-1 | CT-1 | 200 A | MHMECH-1 |
| A074 | CT-2 | CT-2 | 200 A | MHMECH-1 |
| A075 | S1HDN1 | S1HDN1 | 600 A | MHMECH-1 |
| A076 | CEPHLS1 | CEPHLS1 | 200 A | MHMECH-1 |
| A077 | CEPHDN1 | CEPHDN1 | 600 A | MHMECH-1 |
| A078 | CHWP-1 | CHWP-1 | 600 A | MHMECH-1 |
| A079 | CHWP-2 | CHWP-2 | 600 A | MHMECH-1 |
| A080 | MAIN | MAIN | 4000 A | MHMECH-2 |
| A081 | CH-1 | CH-1 | 2000 A | MHMECH-2 |
| A082 | CH-2 | CH-2 | 2000 A | MHMECH-2 |
| A083 | CWP-3 | CWP-3 | 300 A | MHMECH-2 |
| A084 | CT-4 | CT-4 | 200 A | MHMECH-2 |
| A085 | FIRE PUMP | FIRE PUMP | 1200 A | MHMECH-2 |
| A086 | CWP-4 | CWP-4 | 300 A | MHMECH-2 |
| A087 | CHWP-3 | CHWP-3 | 600 A | MHMECH-2 |
| A088 | CHWP-4 | CHWP-4 | 600 A | MHMECH-2 |
| A089 | CT-3 | CT-3 | 200 A | MHMECH-2 |
| PANELS | SIZE | |
| A090 | BQHL - 2 | 150 A |
| A091 | BQHP - 2 | 150 A |
| A092 | BQT - 2 | 30 KVA |
| 4. ASCO ROOM | ||
| BREAKER | SIZE | |
| A093 | 52-2-A | 1200A |
| A094 | 52-2-B | 1200A |
| A095 | 52-2-C | 1200A |
| A096 | 52-2-D | 1200A |
| A097 | 52-2-F | 1200A |
| A098 | 52-2-G | |
| A099 | 52-1-A | 1200A |
| A100 | 52-1-B | 1200A |
| A101 | 52-1-C | 1200A |
| A102 | 52-1-D | 1200A |
| A103 | 52-1-F | |
| A104 | 52-1-G | |
| A105 | 52-G-6 | 1200A |
| A106 | 52-G-7 | 1200A |
| A107 | 52-G-8 | 1200A |
| A108 | 52-G-9 | 1200A |
| A109 | 52-G-10 | 1200A |
| A110 | 52-G-11 | 1200A |
| A111 | 52-G-12 | 1200A |
| PANELS | SIZE | |
| A112 | BQHL - 1 | 150 A |
| A113 | BQHP - 1 | 150 A |
| A114 | BQT - 1 | 45 KVA |
| 5. ELEVATOR PENTHOUSE | ||||
| BREAKER | SIZE | SUB-STATION | ||
| A115 | Main | MAIN | 800 A | P-NHP |
| A116 | Elevator P1 | ELEVATOR - P1 | 100 A | P-NHP |
| A117 | Elevator P2 | ELEVATOR - P2 | 100 A | P-NHP |
| A118 | Elevator P3 | ELEVATOR - P3 | 100 A | P-NHP |
| A119 | Elevator P4 | ELEVATOR - S4 | 100 A | P-NHP |
| A120 | Elevator P5 | ELEVATOR - S5 | 100 A | P-NHP |
| A121 | Elevator P6 | ELEVATOR - S6 | 100 A | P-NHP |
| A122 | Elevator S7 | ELEVATOR - S7 | 100 A | P-NHP |
| A123 | Elevator S8 | ELEVATOR - S8 | 100 A | P-NHP |
| A124 | Elevator S9 | ELEVATOR - S9 | 100 A | P-NHP |
| Chillers and Bus Ducts | |
| A125 | All bus ducts from switchgear thru all of building and installed breakers (90 Buses tap breakers) |
| A126 | Chiller Unit #1 Control Panel (Variable Frequency Drive) |
| A127 | Chiller Unit #2 Control Panel (Variable Frequency Drive) |
| A128 | Chiller Unit #3 Control Panel |
| A129 | Chiller Unit #4 Control Panel |
| 6. SERVICE BAYS BUILDING 100 | |||||
| SERVICE BAYS 1st Floor | PANEL | MAIN BREAKER | BREAKERS | ||
| A130 | SB1-1 | 1BNLP -1 | 100 | 37 | 3 Transformers and 11 Power Panels |
| A131 | SB1-1 | 1BLNP-2 | MLO | 35 | |
| A132 | SB1-1 | 1BCLP | 30 | 12 | |
| A133 | SB1-1 | 1BLQLP | 50 | 30 | |
| A134 | SB1-1 | 1BLLP | MLO | 9 | |
| A135 | SB1-1 | 1BNLP-3 | 225 | 2 | |
| A136 | SB1-1 | 1BNHL-1 | MLO | 3 | |
| A137 | SB1-1 | 1BNHL | MLO | 30 | |
| A138 | SB1-1 | 1BCHL | MLO | 4 | |
| A139 | SB1-1 | 1BQHL | MLO | 11 | |
| A140 | SB1-1 | 1BLHL | MLO | 10 | |
| A141 | SB1-1 | 1BQLP | MLO | 20 | |
| A142 | SB1-2 | 1CNLP | 50 | 38 | 5 Transformers and 10 Power Panels |
| A143 | SB1-2 | 1CCLP | 30 | 15 | |
| A144 | SB1-2 | 1CQLP | 250 | 35 | |
| A145 | SB1-2 | 1CQHP | MLO | 14 | |
| A146 | SB1-2 | 1CLLP | MLO | 7 | |
| A147 | SB1-2 | 1CNHL | MLO | 20 | |
| A148 | SB1-2 | 1CCHL | MLO | 4 | |
| A149 | SB1-2 | 1CQHL | MLO | 6 | |
| A150 | SB1-2 | 1CLHL | MLO | 4 | |
| A151 | SB1-2 | 1CCLP-2 | MLO | 5 | |
| A152 | SB1-3 | lDNLP | 100 | 29 | 3 Transformers and 10 Power Panels |
| A153 | SB1-3 | lDCLP | 30 | 6 | |
| A154 | SB1-3 | lDQLP | 250 | 22 | |
| A155 | SB1-3 | lDLLP | MLO | 6 | |
| A156 | SB1-3 | lDNHL | MLO | 22 | |
| A157 | SB1-3 | lDCHL | MLO | 4 | |
| A158 | SB1-3 | lDQHL | MLO | 4 | |
| A159 | SB1-3 | lDLHL | MLO | 4 | |
| A160 | SB1-3 | lDNLP-2 | 225 | 3 | |
| A161 | SB1-4 | lENHL | MLO | 13 | 6 Transformers, 14 Power Panels |
| A162 | SB1-4 | lENLP-1 | 100 | 38 | |
| A163 | SB1-4 | lNLP-2 | MLO | 25 | |
| A164 | SB1-4 | lEQLP-1 | 125 | 31 | |
| A165 | SB1-4 | lEQLP-2 | 70 | 42 | |
| A166 | SB1-4 | lEQLP-3 | 200 | 14 | |
| A167 | SB1-4 | lECLP | 30 | 8 | |
| A168 | SB1-4 | lECLHL | MLO | 5 | |
| A169 | SB1-4 | lENLP-3 | 225 | 26 | |
| A170 | SB1-4 | lECHL | MLO | 5 | |
| A171 | SB1-4 | lEQHL | MLO | 20 | |
| A172 | SB1-4 | lELLP | MLO | 6 | |
| A173 | SB1-4 | lEQLP-4 | 225 | 30 | |
| A174 | SB1-6 | lAQHL | MLO | 4 | |
| A175 | SB1-6 | lACHL | 50 | 4 | |
| A176 | SB1-6 | lALHL | MLO | 7 | |
| A177 | SB1-6 | lALLP | MLO | 6 | |
| A178 | SB1-6 | lACLP | 30 | 8 | |
| A179 | SB1-6 | lAQLP | 30 | 27 | |
| A180 | SB1-6 | lANLP-4 | 70 | 41 | |
| A181 | SB1-6 | lANLP-3 | 70 | 33 | |
| A182 | SB1-6 | lANLP-2 | 70 | 41 | |
| A183 | SB1-6 | lANLP-1 | 70 | 38 | |
| A184 | SB1-6 | lANHL | MLO | 26 | |
| A185 | SB1-6 | 1A-QLP-2 | 225 | 14 | |
| A186 | SB1-6 | Disc. For all NLP panels | 250 | N/A | |
| A187 | SB1-7 | lJNlP | 100 | 34 | 5 Transformers, 8 Power Panels |
| A188 | SB1-7 | lJCLP | 30 | 18 | |
| A189 | SB1-7 | lJQLP | 30 | 10 | |
| A190 | SB1-7 | lJLLP | 30 | 6 | |
| A191 | SB1-7 | lJNHL | MLO | 32 | |
| A192 | SB1-7 | lJCHL | MLO | 7 | |
| A193 | SB1-7 | lJQHL | MLO | 7 | |
| A194 | SB1-7 | lJLHL | MLO | 4 | |
| A195 | SB1-7 | ND-lJ-A | 150 | 1 | |
| A196 | SB1-7 | ND-lJ-B | 150 | 1 | |
| A197 | SB1-7 | NLP-2 | 100 | 30 | |
| A198 | SB1-8 | lHNLP-1 | 70 | 42 | 6 Transformers, 11 Power Panels |
| A199 | SB1-8 | lHNLP-2 | 70 | 39 | |
| A200 | SB1-8 | lHNLP-3 | 70 | 24 | |
| A201 | SB1-8 | lHCLP | 100 | 40 | |
| A202 | SB1-8 | lHQLP | 100 | 42 | |
| A203 | SB1-8 | lHLLP | 30 | 9 | |
| A204 | SB1-8 | lHNHL | MLO | 19 | |
| A205 | SB1-8 | lHCHL | MLO | 13 | |
| A206 | SB1-8 | lHQHL | MLO | 12 | |
| A207 | SB1-8 | lHLHL | MLO | 6 | |
| A208 | SB1-8 | lHQLP-2 | 225 | 32 | |
| A209 | SB1-8 | lHQLP-3 | 150 | 36 | |
| A210 | SB1-8 | lHCLP-2 | 225 | 29 | |
| A211 | SB1-9 | lGNLP-1 | 100 | 40 | 6 Transformers, 11 Power Panels |
| A212 | SB1-9 | lGNLP-2 | MLO | 26 | |
| A213 | SB1-9 | lG-CLP | 30 | 6 | |
| A214 | SB1-9 | lG-QLP | 50 | 30 | |
| A215 | SB1-9 | lG-LLP | 30 | 8 | |
| A216 | SB1-9 | lG-NHL | MLO | 11 | |
| A217 | SB1-9 | lG-CHL | MLO | 8 | |
| A218 | SB1-9 | lG-QHL | MLO | 13 | |
| A219 | SB1-9 | lG-LHL | MLO | 6 | |
| A220 | SB1-9 | MRI | 225 | 2 | |
| A221 | SB1-9 | 16QLP-2 | 225 | 9 | |
| A222 | SB1-10 | lFNLP-1 | MLO | 40 | 6 Transformers, 11 Power Panels |
| A223 | SB1-10 | lFNLP-2 | 100 | 38 | |
| A224 | SB1-10 | lFCLP | 60 | 38 | |
| A225 | SB1-10 | lFQLP | 30 | 30 | |
| A226 | SB1-10 | lFLLP | 30 | 8 | |
| A227 | SB1-10 | lFNHL | MLO | 30 | |
| A228 | SB1-10 | lFNHL-1 | TRANS NT-1F (70) | 3 | |
| A229 | SB1-10 | lFCHL | MLO | 5 | |
| A230 | SB1-10 | lFQHL | MLO | 14 | |
| A231 | SB1-10 | lFLHL | MLO | 8 | |
| A232 | SB1-10 | lFQLP-2 | 225 | 17 | |
| SERVICE BAYS 2nd Floor | PANEL | MAIN BREAKER | BREAKERS | ||
| A233 | SB2-1 | 2BNLP-1 | 50 | 40 | 5 Transformers, 9 Power Panels |
| A234 | SB2-1 | 2BCLP-1 | 250 | 35 | |
| A235 | SB2-1 | 2BQLP | 50 | 14 | |
| A236 | SB2-1 | 2BLLP | 70 | 13 | |
| A237 | SB2-1 | 2BQLP-2 | 225 | 18 | |
| A238 | SB2-1 | 2BLHL | MLO | 9 | |
| A239 | SB2-1 | 2BQHL | MLO | 9 | |
| A240 | SB2-1 | 2BCHL | MLO | 8 | |
| A241 | SB2-1 | 2BNHL | MLO | 10 | |
| A242 | SB2-1 | U PS | MLO | 7 | |
| A243 | SB2-2 | 2DNLP-1 | 50 | 41 | 6 Transformers, 11 Power Panels |
| A244 | SB2-2 | 2DNLP -2 | 70 | 40 | |
| A245 | SB2-2 | 2DNL P-3 | 50 | 24 | |
| A246 | SB2-2 | 2DCLP | 50 | 27 | |
| A247 | SB2-2 | 2DQLP-1 | 50 | 25 | |
| A248 | SB2-2 | 2DLLP | 50 | 7 | |
| A249 | SB2-2 | 2DQLP-2 | 225 | 11 | |
| A250 | SB2-2 | 2DCHL-2 | 225 | 10 | |
| A251 | SB2-2 | 2DNHL | MLO | 14 | |
| A252 | SB2-2 | 2DCHL | MLO | 10 | |
| A253 | SB2-2 | 2DQHL | MLO | 4 | |
| A254 | SB2-2 | 2DLHL | MLO | 6 | |
| A255 | SB2-2 | PAC'S(UPS) | MLO | 35 | |
| A256 | SB2-3 | 2FNLP-l | MLO | 40 | 6 Transformers, 12 Power Panels |
| A257 | SB2-3 | 2FNLP-2 | 100 | 37 | |
| A258 | SB2-3 | 2FCLP | 50 | 26 | |
| A259 | SB2-3 | 2FQLP-l | 50 | 39 | |
| A260 | SB2-3 | 2FQLP-2 | 100 | 28 | |
| A261 | SB2-3 | 2FQLP-3 | 100 | 40 | |
| A262 | SB2-3 | 2FQLP-4 | 50 | 36 | |
| A263 | SB2-3 | 2FNHL | MLO | 12 | |
| A264 | SB2-3 | 2FCHL | MLO | 5 | |
| A265 | SB2-3 | 2FQHL | MLO | 16 | |
| A266 | SB2-3 | 2FLHL | MLO | 11 | |
| A267 | SB2-3 | 2FLLP | 100 | 10 | |
| A268 | SB2-3 | 2F-UPS-l | 100 | 32 | |
| A269 | SB2-3 | 2F-UPS-2 | 70 | 24 | |
| A270 | SB2-3 | 2FQLP-5 | 100 | 23 | |
| A271 | SB2-4 | 2ENLP-l | 100 | 39 | 5 Transformers, 12 Power Panels |
| A272 | SB2-4 | 2ENLP-2 | MLO | 24 | |
| A273 | SB2-4 | 2ECLP | 30 | 6 | |
| A274 | SB2-4 | 2EQLP-1 | MLO | 31 | |
| A275 | SB2-4 | 2EQLP-2 | 100 | 33 | |
| A276 | SB2-4 | 2ELLP | 100 | 10 | |
| A277 | SB2-4 | 2ECLP-2 | 225 | 9 | |
| A278 | SB2-4 | 2ENHL | MLO | 14 | |
| A279 | SB2-4 | 2ECHL | MLO | 5 | |
| A280 | SB2-4 | 2EQHL | MLO | 5 | |
| A281 | SB2-4 | 2ELHL | MLO | 11 | |
| A282 | SB2-4 | UPSl | 200 | 31 | |
| A283 | SB2-4 | UPS2 | MLO | 13 | |
| A284 | SB2-5 | 2CNLP-1 | MLO | 41 | 6 Transformers, 13 Power Panels |
| A285 | SB2-5 | 2CNLP-2 | 100 | 18 | |
| A286 | SB2-5 | 2CCLP-1 | 70 | 42 | |
| A287 | SB2-5 | 2CCLP-2 | 70 | 40 | |
| A288 | SB2-5 | 2CCLP-3 | 70 | 13 | |
| A289 | SB2-5 | 2CQLP | 70 | 18 | |
| A290 | SB2-5 | 2CLLP | 30 | 7 | |
| A291 | SB2-5 | 2CQLP-2 | 225 | 5 | |
| A292 | SB2-5 | 2CNHL | MLO | 12 | |
| A293 | SB2-5 | 2CCHL | MLO | 21 | |
| A294 | SB2-5 | 2CQHL | MLO | 7 | |
| A295 | SB2-5 | 2CLHL | MLO | 6 | |
| A296 | SB2-5 | 2C??? | 30 | 11 | |
| A297 | SB2-5 | UPS | MLO | 3 | |
| A298 | SB2-6 | 2ANLP-1 | 50 | 29 | 5 Transformers, 9 Power Panels |
| A299 | SB2-6 | 2ACLP-l | 150 | 23 | |
| A300 | SB2-6 | 2AQLP | 30 | 12 | |
| A301 | SB2-6 | 2ALLP | 100 | 16 | |
| A302 | SB2-6 | 2AQLP-2 | 225 | 7 | |
| A303 | SB2-6 | 2ALHL | MLO | 10 | |
| A304 | SB2-6 | 2AQHL | MLO | 8 | |
| A305 | SB2-6 | 2ACHL | MLO | 5 | |
| A306 | SB2-6 | 2ANHL | MLO | 10 | |
| A307 | SB2-6 | UPS-2 | 30 | 6 | |
| A308 | SB2-6 | UPS-1 | 225 | 39 | |
| SERVICE BAYS 3rd Floor | PANEL | MAIN BREAKER | BREAKERS | ||
| A309 | SB3-1 | 3ANLP-l | 70 | 42 | 3 Transformers, 12 Power Panels |
| A310 | SB3-1 | 3ANLP-2 | 70 | 42 | |
| A311 | SB3-1 | 3ANLP-3 | 50 | 26 | |
| A312 | SB3-1 | 3ACLP-1 | MLO | 42 | |
| A313 | SB3-1 | 3ACLP-2 | 150 | 20 | |
| A314 | SB3-1 | 3AQLP | 50 | 11 | |
| A315 | SB3-1 | 3ALLP | MLO | 7 | |
| A316 | SB3-1 | 3ANHL | MLO | 11 | |
| A317 | SB3-1 | 3ACHL | MLO | 4 | |
| A318 | SB3-1 | 3AQHL | MLO | 3 | |
| A319 | SB3-1 | 3ALHL | MLO | 12 | |
| A320 | SB3-3 | 3BNLP-1 | 70 | 42 | 3 Transformers, 12 Power Panels |
| A321 | SB3-3 | 3BNLP-2 | 70 | 42 | |
| A322 | SB3-3 | 3BNLP-3 | 70 | 42 | |
| A323 | SB3-3 | 3BNLP-4 | 70 | 20 | |
| A324 | SB3-3 | 3BCLP-1 | 100 | 40 | |
| A325 | SB3-3 | 3BCLP-2 | MLO | 30 | |
| A326 | SB3-3 | 3BQLP | 30 | 17 | |
| A327 | SB3-3 | 3BNHL | MLO | 14 | |
| A328 | SB3-3 | 3BCHL | MLO | 4 | |
| A329 | SB3-3 | 3BQHL | MLO | 4 | |
| A330 | SB3-3 | 3BLHL | MLO | 12 | |
| A331 | SB3-3 | 3BLLP | MLO | 4 | |
| A332 | SB3-4 | 3CNLP-1 | 70 | 42 | 2 Transformers, 10 Power Panels |
| A333 | SB3-4 | 3CNLP-2 | 70 | 42 | |
| A334 | SB3-4 | 3CNLP-3 | 70 | 22 | |
| A335 | SB3-4 | 3CCLP-1 | 100 | 42 | |
| A336 | SB3-4 | 3CQLP | 30 | 14 | |
| A337 | SB3-4 | 3CLLP | MLO | 7 | |
| A338 | SB3-4 | 3CNHL | MLO | 7 | |
| A339 | SB3-4 | 3CCHL | MLO | 4 | |
| A340 | SB3-4 | 3CQHL | MLO | 4 | |
| A341 | SB3-4 | 3CLHL | MLO | 11 | |
| A342 | SB3-6 | 3DNLP-l | 70 | 42 | 3 Transformers, 12 Power Panels |
| A343 | SB3-6 | 3DNLP-2 | 70 | 41 | |
| A344 | SB3-6 | 3DNLP-3 | 70 | 20 | |
| A345 | SB3-6 | 3DCLP-l | 100 | 42 | |
| A346 | SB3-6 | 3DQLP | 30 | 14 | |
| A347 | SB3-6 | 3DLLP | MLO | 7 | |
| A348 | SB3-6 | 3DNHL | MLO | 7 | |
| A349 | SB3-6 | 3DCHL | MLO | 4 | |
| A350 | SB3-6 | 3DQHL | MLO | 4 | |
| A351 | SB3-6 | 3DLHL | MLO | 10 | |
| SERVICE BAYS 4th Floor | PANEL | MAIN BREAKER | BREAKERS | ||
| A352 | SB4-1 | 4ANLP-1 | 70 | 40 | 3 Transformers, 10 Power Panels |
| A353 | SB4-1 | 4ANLP-2 | 70 | 42 | |
| A354 | SB4-1 | 4ANLP-3 | 70 | 27 | |
| A355 | SB4-1 | 4ACLP-l | 100 | 42 | |
| A356 | SB4-1 | 4AQLP | 30 | 12 | |
| A357 | SB4-1 | 4ALLP | MLO | 7 | |
| A358 | SB4-1 | 4ANHL | MLO | 13 | |
| A359 | SB4-1 | 4ACHL | MLO | 5 | |
| A360 | SB4-1 | 4AQHL | MLO | 4 | |
| A361 | SB4-1 | 4ALHL | MLO | 5 | |
| A362 | SB4-3 | 4BNLP-l | 70 | 42 | 3 Transformers, 10 Power Panels |
| A363 | SB4-3 | 4BNLP-2 | 70 | 42 | |
| A364 | SB4-3 | 4BNLP-3 | 70 | 32 | |
| A365 | SB4-3 | 4BCLP-1 | 100 | 41 | |
| A366 | SB4-3 | 4BQLP | 100 | 18 | |
| A367 | SB4-3 | 4BLLP | MLO | 7 | |
| A368 | SB4-3 | 4BNHL | MLO | 13 | |
| A369 | SB4-3 | 4BCHL | MLO | 4 | |
| A370 | SB4-3 | 4BQHL | MLO | 4 | |
| A371 | SB4-3 | 4BLHL | MLO | 6 | |
| A372 | SB4-4 | 4CNLP-l | 70 | 42 | 3 Transformers, 10 Power Panels |
| A373 | SB4-4 | 4CNLP-2 | 70 | 41 | |
| A374 | SB4-4 | 4CNLP-3 | 70 | 19 | |
| A375 | SB4-4 | 4CCLP-1 | 100 | 41 | |
| A376 | SB4-4 | 4CQLP | 100 | 34 | |
| A377 | SB4-4 | 4CLLP | MLO | 7 | |
| A378 | SB4-4 | 4CNHL | MLO | 8 | |
| A379 | SB4-4 | 4CCHL | MLO | 4 | |
| A380 | SB4-4 | 4CQHL | MLO | 5 | |
| A381 | SB4-4 | 4CLHL | MLO | 4 | |
| A382 | SB4-6 | 4DNLP-l | 70 | 42 | 3 Transformers, 10 Power Panels |
| A383 | SB4-6 | 4DNLP-2 | 70 | 42 | |
| A384 | SB4-6 | 4DNLP-3 | 70 | 20 | |
| A385 | SB4-6 | 4DCLP-1 | 100 | 41 | |
| A386 | SB4-6 | 4DQLP | 30 | 12 | |
| A387 | SB4-6 | 4DLLP | MLO | 7 | |
| A388 | SB4-6 | 4DNHL | MLO | 8 | |
| A389 | SB4-6 | 4DCHL | MLO | 4 | |
| A390 | SB4-6 | 4DQHL | MLO | 4 | |
| A391 | SB4-6 | 4DLHL | MLO | 4 | |
| A392 | SB4-6 | 4DCLP-2 | 100 | 22 | |
| A393 | SB4-6 | 5ANLP-1 | 70 | 42 | |
| SERVICE BAYS 5th Floor | PANEL | MAIN BREAKER | BREAKERS | ||
| A394 | SB5-1 | 5ANLP-2 | 70 | 42 | 3 Transformers, 10 Power Panels |
| A395 | SB5-1 | 5ANLP-3 | 70 | 27 | |
| A396 | SB5-1 | 5ACLP-1 | 100 | 42 | |
| A397 | SB5-1 | 5AQLP | 30 | 13 | |
| A398 | SB5-1 | 5ALLP | MLO | 7 | |
| A399 | SB5-1 | 5ANHL | MLO | 12 | |
| A400 | SB5-1 | 5ACHL | MLO | 5 | |
| A401 | SB5-1 | 5AQHL | MLO | 6 | |
| A402 | SB5-1 | 5ALHL | MLO | 6 | |
| A403 | SB5-3 | 5BNLP-1 | 70 | 42 | 3 Transformers, 10 Power Panels |
| A404 | SB5-3 | SBNLP-2 | 70 | 42 | |
| A405 | SB5-3 | SBNLP-3 | 70 | 30 | |
| A406 | SB5-3 | SBCLP-1 | 100 | 42 | |
| A407 | SB5-3 | SBQLP | 30 | 17 | |
| A408 | SB5-3 | SBLLP | MLO | 7 | |
| A409 | SB5-3 | SBLHL | MLO | 6 | |
| A410 | SB5-3 | SBQHL | MLO | 11 | |
| A411 | SB5-3 | SBCHL | MLO | 4 | |
| A412 | SB5-3 | 5BNHL | MLO | 13 | |
| A413 | SB5-4 | 5CNLP-1 | 70 | 42 | 3 Transformers, 10 Power Panels |
| A414 | SB5-4 | 5CNLP-2 | 70 | 42 | |
| A415 | SB5-4 | 5CNLP-3 | 70 | 18 | |
| A416 | SB5-4 | 5CCLP-1 | 100 | 42 | |
| A417 | SB5-4 | 5CQLP | 30 | 15 | |
| A418 | SB5-4 | 5CLLP | MLO | 7 | |
| A419 | SB5-4 | 5CLHL | MLO | 4 | |
| A420 | SB5-4 | 5CQHL | MLO | 8 | |
| A421 | SB5-4 | 5CCHL | MLO | 4 | |
| A422 | SB5-4 | 5CNHL | MLO | 8 | |
| A423 | SB5-4 | 5CNLP-4 | 200 | 15 | |
| A424 | SB5-6 | 5DNLP-1 | 70 | 41 | 3 Transformers, 10 Power Panels |
| A425 | SB5-6 | 5DNLP-2 | 70 | 40 | |
| A426 | SB5-6 | 5DNLP-3 | 70 | 20 | |
| A427 | SB5-6 | 5DCLP-1 | 100 | 42 | |
| A428 | SB5-6 | 5DQLP | 30 | 16 | |
| A429 | SB5-6 | 5DLLP | MLO | 7 | |
| A430 | SB5-6 | 5DLHL | MLO | 4 | |
| A431 | SB5-6 | 5DQHL | MLO | 5 | |
| A432 | SB5-6 | 5DCHL | MLO | 4 | |
| A433 | SB5-6 | 5DNHL | MLO | 7 |
| A434 | Room 1B104 | 1 Power Panel |
| A435 | Room 1A103 | 1 Power Panel |
| A436 | Room 1C107 | 1 Power Panel |
| A437 | Room 1F110 | 1 Power Panel |
| A438 | Room 1F111 | 1 Power Panel |
| A439 | Room 1F113 | 1 Power Panel |
| A440 | Room 1F122 | 1 Power Panel |
| A441 | Room 1F123 | 1 Power Panel |
| A442 | Room 1F124 | 1 Power Panel |
| A443 | Room 1F100 | 1 Power Panel, 2 Transformers |
| A444 | Room 1F114 | 6 Power Panels, 3 Transformers |
| A445 | Room 1F115 | 1 Power Panel |
| A446 | Room 1F116 | 1 Power Panel, 1 Transformer |
&"-,Bold"ELECTRICAL INVENTORY BUILDING 100
B-106
| 1. PANELS / ROOMS 1G -143 | ||||
| ELIN | PANEL ID | SIZE | MAIN | |
| B001 | MDP | 1200A | MCB | |
| B002 | MDP | 400 A | Feeder breakers | |
| B003 | MDP | 400 A | Feeder breakers | |
| B004 | MDP | 250 A | Feeder breakers | |
| B005 | MDP | 150 A | Feeder breakers | |
| B006 | MDP | 125 A | Feeder breakers | |
| B007 | MDP | 125 A | Feeder breakers | |
| B008 | MDP | 100 A | Feeder breakers | |
| B009 | MDP | 60 A | Feeder breakers | |
| B010 | MDP | 60 A | Feeder breakers | |
| PANEL ID | SIZE | MAIN | BREAKERS | |
| B011 | 1NHLL | 100 A | MLO | 42 |
| B012 | 1QHLM | 225 A | MLO | 42 |
| B013 | 1NLPG1 | 300 A | MCB | 24 |
| B014 | 1NLPG2 | 225 A | MLO | 42 |
| B015 | 1LLPG | 100 A | MLO | 30 |
| 2. PANELS / ROOMS 1G -143B | ||||
| PANEL ID | SIZE | MAIN | BREAKERS | |
| B016 | 1NLPG3 | 225 A | MLO | 42 |
| B017 | 1NLPG4 | 225 A | MLO | 42 |
| 3. PANELS / ROOMS 2G -168 | ||||
| PANEL ID | SIZE | MAIN | ||
| B018 | E- MDP | 300 A | MCB | |
| B019 | E- MDP | 150 A | Feeder breakers | |
| B020 | E- MDP | 100 A | Feeder breakers | |
| B021 | 2NLPG | 300 A | MCB | 20 |
| B022 | 2CLPG1 | 300 A | MCB | 42 |
| B023 | 2QLPM | 60 A | MCB | 42 |
| B024 | 2LLPG | 100 A | MCB | 30 |
| B025 | 2QHLM1 | 400 A | MLO | 30 |
| B026 | 2NHLL | 100 A | MLO | 42 |
| B027 | 2LHLG | 125 A | MLO | 30 |
| B028 | 2NLPG1 | 225 A | MLO | 42 |
| B029 | 2QHLM2 | 125 A | MLO | 30 |
| B030 | 2CHLG | 250 A | MLO | 42 |
| 5. PANELS / ROOMS 2G - 146 | ||||
| PANEL ID | SIZE | MAIN | BREAKERS | |
| B031 | 2CLPG2 | 225 A | MLO | 42 |
| 6. PANELS / ROOMS 2G - 145 | ||||
| PANEL ID | SIZE | MAIN | BREAKERS | |
| B032 | 2CLPG3 | 225 A | MLO | 42 |
| B033 | 2NLPG2 | 225 A | MLO | 42 |
&"-,Bold"ELECTRICAL INVENTORY BUILDING 106
B-300
| ELIN | PANEL ID | SIZE | MAIN | BREAKERS |
| C001 | NLP-A-300 | 300 A | MCB | 42 |
| C002 | NLP-B-300 | 400 A | MLO | 30 |
| C003 | EDP-300 | 125 A | MLO | 16 |
&"-,Bold"ELECTRICAL INVENTORY BUILDING 300
B-107
| Electrical Inventory Building 107 |
| Bldg 107 ROC 1 |
| Transformer | T107 | ABB |
| MDP |
| ELIN | Bldg 107 | Manufacture | Type | Amp Frame | Amp Trip | Feeder ID | AIC | Fed from | |
| D001 | Sq D | I-Line | 1200 | 1200 | T107 | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| D002 | Main | ||||
| Breaker | Sq D | PowerPact | |||
| RK1200 | 1200 | 1200 | T107 | ||
| D003 | Sq D | PowerPact | |||
| HJA36150 | HJ150 | 150 | Linac 1 | ||
| D004 | Sq D | PowerPact | |||
| HJA36150 | HJ150 | 150 | Linac 2 | ||
| D005 | Sq D | PowerPact | |||
| HJA36060 | HJ060 | 60 | Surge Protection | ||
| D006 | Sq D | PowerPact | |||
| JJA36175 | JJ175 | 175 | TX-NLP | ||
| D007 | Sq D | PowerPact | |||
| JJA36225 | JJ225 | 225 | NHL2, NHL3 | ||
| D008 | Sq D | PowerPact | |||
| HJA36125 | HJ150 | 125 | CT Scan | ||
| D009 | Sq D | PowerPact | |||
| HJA36100 | HJ150 | 100 | NHL1 | ||
| D010 | Sq D | PowerPact | |||
| HJA36015 | HJ060 | 15 | Emon Meter | ||
| D011 | Sq D | PowerPact | |||
| HJA36040 | HJ060 | 40 | Linac Chiller 1 | ||
| D012 | Sq D | PowerPact | |||
| HJA36040 | HJ060 | 40 | Linac Chiller 2 |
D013 Transformer Sq D TX-NLP 480 to 120/208 3P 112.5KVA Cat # EE112T3HCU
| PANEL | |||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES | |
| D014 | NLP-1 | Sq D | NQ | SP126-107-BP | 120/208 3P 4W | 400A MCB | TX-NLP | ||
| D015 | NLP-2 | Sq D | NQ | SP126-107-BP | 120/208 3P 4W | 400A MLO | TX-NLP | ||
| D016 | NLP-2A | Sq D | NQ | SP126-107-BP | 120/208 3P 4W | 100A MLO | NLP-2 | ||
| D017 | NLP-3 | Sq D | NQ | SP126-107-BP | 120/208 3P 4W | 40A MLO | NLP-2 | ||
| D018 | NHL1 | Sq D | NF | SP126-107-BP | 277/480 3P 4W | 100A MLO | MDP | ||
| D019 | NHL2 | Sq D | NF | SP126-107-BP | 277/480 3P 4W | 225A MLO | MDP | ||
| D020 | NHL3 | Sq D | NF | SP126-107-BP | 277/480 3P 4W | 225A MLO | MDP | ||
| D021 | Lighting Relay | ||||||||
| Panel | ILC Intelligent | ||||||||
| Lighting Control | Apprentice | ||||||||
| 2 | SP126-107-BP | 277/480 3P 4W | WHL1 | Lights |
&"-,Bold"Electrical Inventory Building 107
B-109
| Electrical Inventory Building 109 |
| Bldg 109 Parking Garage |
| ELIN | Transformer | |
| E001 | T-109 | 12,470V 3P--480/277 3P 4W |
| Transformer | Sq D | |
| E002 | H-1 | 480/277 3P 3W--208/120 3P 4W |
| PANEL | |||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| E003 | H | Sq D | Second Floor | ||
| Electrical Room | 277/480 3P 4W | 400A MCB | T-109 | 42 Circuits | |
| E004 | L | Sq D | Second Floor | ||
| Electrical Room | 120/208 3P 4W | 400A MLO | 42 Circuits |
&"-,Bold"Electrical Inventory Building 109
B-22
| ELIN | Sub Station | |||||||
| F001 | Transformer | T-22 | 500 KVA | |||||
| PANEL | ||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES |
| F002 | Main | 1600A | ||||||
| F003 | NHIS | 150A | ||||||
| F004 | NH3S | 150A | ||||||
| F005 | NHIN | 150A | ||||||
| F006 | NH3N | 150A | ||||||
| F007 | EMDP | 250A |
| PANEL | |||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES | |
| F008 | Bldg 22 | ||||||||
| F009 | NHIN | Room 130 | 70A | MCB | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| F010 | ELIN | Room 130 | 30A | MCB |
| F011 | NLIN-1 | Room 130 | 50A | MCB |
| F012 | NLIN-2 | Room 130 | 125A | MCB |
| F013 | EHIN | Room 130 | 30A | MCB |
| F014 | NHIS | Room 110 | 90A | MCB |
| F015 | NLIS-1 | Room 110 | 100A | MCB |
| F016 | NLIS-2 | Room 110 | 100A | MCB |
| F017 | LHIS | Room 110 | 30A | MCB |
| F018 | LLIS | Room 110 | 30A | MCB |
| F019 | EL2N | Room 209 | 30A | MCB |
| F020 | EL3N-1 | Room 344 | 30A | MCB |
| F021 | NH3S | Room 309 | 70A | MCB |
| F022 | NL3S-1 | Room 309 | 50A | MCB |
| F023 | NL3S-2 | Room 309 | 100A | MCB |
| F024 | LH3S | Room 309 | 100A | MLO |
| F025 | NH4N | Room 435 | 70A | MCB |
| F026 | NL4N-1 | Room 435 | 50A | MCB |
| F027 | NL4N-2 | Room 435 | 100A | MCB |
| F028 | NH2N | Room 210 | 90A | MCB |
| F029 | NL2N | Room 210 | 100A | MCB |
| F030 | EH2N | Room 210 | 30A | MCB |
| F031 | NH2S | Room 209 | 90A | MCB |
| F032 | NL2S-1 | Room 209 | 100A | MCB |
| F033 | NL2S-2 | Room 209 | 100A | MCB |
| F034 | NL3N-1 | Room 344 | 100A | MCB |
| F035 | EL3N-2 | Room 344 | 100A | MCB |
| F036 | EH3N | Room 344 | 30A | MCB |
| F037 | NH3N | Room 344 | 90A | MCB |
| F038 | EH4N | Room 435 | 70A | MCB |
| F039 | EL4N | Room 435 | 70A | MCB |
| F040 | NH4S | Room 407 | 50A | MCB |
| F041 | NL4S-1 | Room 407 | 50A | MCB |
| F042 | NL4S-2 | Room 407 | 100A | MCB |
&"-,Bold"Electrical Inventory Building 22
B-20
| Electrical Inventory Building 20 | ||||
| Bldg 20, Post Office, Education | ||||
| ELIN | ||||
| G001 | Transformer | T-20 | 12,470V--120/208V 3P 4W | Two breakers are |
located in Stainless Steel enclosure, located outside
| Manufacture | Type | Amp Frame | Amp Trip | Feeder ID | AIC | Fed from | ||
| G002 | Feeder Breaker | 250A | T-20 | |||||
| G003 | Feeder Breaker | 400A | T-20 |
| PANEL | ||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES |
G004 MDP 120/208 3P 4W Latest breaker PMI and testing results are located in electrical shop room B100F123
| G005 | MDP-1 | 400A |
| G006 | MDP-2 | 400A |
| G007 | MDP-3 | 400A |
| G008 | MDP-4 | 400A |
| G009 | MDP-5 | 400A |
| G010 | MDP-6 | 400A |
| PANEL | ||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES |
| G011 | Panel 20 | 120/208 3P 4W | 100 | MLO | ||||
| G012 | Panel B | 120/208 3P 4W | 225 | MCB | ||||
| G013 | Panel D | 120/208 3P 4W | 225 | MCB | ||||
| G014 | Power Panel | 120/208 3P 4W | ||||||
| G015 | Power Panel | 120/208 3P 4W | ||||||
| G016 | Power Panel | 120/208 3P 4W | ||||||
| G017 | Power Panel | 120/208 3P 4W |
&"-,Bold"Electrical Inventory Building 20
B-103
| Electrical Inventory Building 103 | ||||||||||
| Pump House | ||||||||||
| ELIN | PANEL | |||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES | ||
| H001 | MDP | Sq D | N/A | 120/208 4 wire | MCB 300A | Building 11 MDP | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
B-1
| Electrical Inventory Listing Bldg 1 | ||||||||
| ELIN | Room B114 | Type | Model | Serial # | Voltage | KW/KVA | ||
| J001 | Cummings Diesel | AP-765DC | 33107027 | 480/277 3P 4W | 600/750 | Notes: Feeds Bldg | ||
| 1 & 22 | PMI and testing results are located in the electric shop B-100, room 1F123 |
| Sub | ||
| station | NDSA SUB-STATION |
Room # B114 Manufacture Type Amp Frame Amp Trip Feeder ID room B114 Fed from
| J002 | Main | |||||||
| Breaker | Westinghouse/Sq D | DS-632 | 3200 | 3200 | NDSA | |||
| J003 | 1 | Westinghouse/Sq D | DS-206 | 800 | 300 | NH1S, | NDSA | |
| J004 | 2 | Westinghouse/Sq D | DS-206 | 800 | 300 | NH2S, NH3S | NDSA | |
| J005 | 3 | Westinghouse/Sq D | DS-206 | 800 | 300 | NH1W, NH3S | NDSA | |
| J006 | 4 | Westinghouse/Sq D | DS-206 | 800 | 300 | NH4S, NH5S, NHAP | NDSA | |
| J007 | 5 | Westinghouse/Sq D | DS-206 | 800 | 300 | NH1N, NH2N | NDSA | |
| J008 | 6 | Westinghouse/Sq D | DS-206 | 800 | 300 | ATS2, CDP | NDSA | |
| J009 | 7 | Westinghouse/Sq D | DS-206 | 800 | 300 | NH3N, NH4N, NH5N | NDSA | |
| J010 | 8 | Westinghouse/Sq D | DS-206 | 800 | 150 | ATS1, LDP | NDSA | |
| J011 | 9 | Westinghouse/Sq D | DS-206 | 800 | 800 | ATS3, QDP | NDSA | |
| J012 | 10 | Westinghouse/Sq D | DS-206 | 800 | 150 | SP | NDSA | |
| J013 | 11 | Westinghouse/Sq D | DS-206 | 800 | 150 | SP | NDSA | |
| 12 | EMPTY | NDSA |
PMI test results are available in electrical shop B100F123. ATS transfer test, see generator log@ each generator.
| ATS'S BLDG 1 | MANUFACTURE | SERIAL # | CAT A # | ROOM # | AIC | FED FROM NORMAL | FED FROM EM | FEED TO | |
| J014 | ATS 1 | ASCO, ATS # 1 | 921374 | C9403215099XC | B114 | 25K | NDSA - 8 | EGDP-1 | LDP |
| J015 | ATS 2 | ASCO, ATS # 2 | 952217 | C940326099XC | B114 | 25K | NDSA - 6 | EGDP-2 | CDP |
| J016 | ATS 3 | ASCO, ATS # 3 | 921377 | C940380099XC | B114 | 25K | NDSA - 9 | EGDP-3 | QDP |
| PANEL | ||||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES | ||
| J017 | EGDP | SEE GENERATOR | B115 | BLDG 1 GEN | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| J018 | LDP | Square D | I-Line | B114 | 277/480V 3P 4W | 225A MLO | NDSA, 8 | EQDP,1 | |
| J019 | CDP | Square D | I-Line | B114 | 277/480V 3P 4W | 400A MLO | NDSA, 6 | EQDP, 2 | |
| J020 | QDP | Square D | I-Line | B114 | 277/480V 3P 4W | 800A MLO | NDSA, 9 | EQDP, 3 | |
| J021 | QH1W | Square D | I-Line | B114 | 277/480V 3P 4W | 400A MLO | QDP-5 | ||
| J022 | T-1QW | Square D | SQ D | B114 | 15KVA | ||||
| J023 | QLIW | Square D | NQOD | B114 | 120/208 3P 4W | 50A 3P MCB | |||
| J024 | NH1W | Square D | NQOD | B116 | 277/480V 3P 4W | 14K | 175A 3P MCB | NDSA, 3 | |
| J025 | T-1NW | Square D | NQOD | B116 | 30KVA | ||||
| J026 | NL1W | Square D | NQOD | B116 | 120/208 3P 4W | 22K | 100A 3P MCB |
| PANEL | ||||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | |||
| J018 | LH1W | Square D | NQOD | B116 | 277/480V 3P 4W | 14K | 100A MLO | LDP, 3 | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| J019 | T-1LS | Square D | NQOD | B116 | 6KVA | LH1W | |||
| J020 | LL1W | Square D | NQOD | B116 | 120/208 3P 4W | 22K | 30A 3P MCB | LH1W | |
| J021 | NH1S | Square D | NQOD | A121 | 277/480V 3P 4W | 14K | 400 MLO | NDSA, 1 | |
| J022 | NHMR | Square D | NQOD | A109 MECH | 277/480V 3P 4W | 14K | 100A MLO | ||
| J023 | T-INS | Square D | SQ D | A121 | 112.5KVA | ||||
| J024 | NLDP | Square D | NQOD | A121 | 120/208 3P 4W | 22K | 400A 3P MCB | ||
| J025 | NLIS SEC1 | Square D | NQOD | A121 | 120/208 3P 4W | 14K | 225 MLO | ||
| J026 | NLIS SEC2 | Square D | NQOD | A121 | 120/208 3P 4W | 22K | 100A MLO | ||
| J027 | NLIK | Square D | NQOD | A118 | 120/208 3P 4W | 22K | 225A MLO | SHUNT TRIP FROM |
A107 KITCHEN
| J028 | NLISS | Square D | NQOD | A121 | 120/208 3P 4W | 22K | 30A 3P MCB | I.G. | |||
| J029 | T-1QM | Square D | NQOD | A118 | 45KVA | QDP, 1 | |||||
| J030 | QL1K | Square D | NQOD | A118 | 120/208 3P 4W | 22K | 100A 3P MCB | QDP, 1 | |||
| J031 | QLI1K1 | Square D | NQOD | A118 | 120/208 3P 4W | 22K | 40A 3P MCB | QDP,1 | |||
| J032 | NH1N | Square D | NQOD | A142 | 277/480V 3P 4W | 14K | 100A 3P MCB | NDSA, 5 | |||
| J033 | T-1NN | Square D | NQOD | A142 | 30KVA | ||||||
| J034 | NL1N | Square D | NQOD | A142 | 120/208 3P 4W | 22K | 100A 3P MCB | ||||
| J035 | LH1N | Square D | NQOD | A142 | 277/480V 3P 4W | 14K | 100A MLO | ||||
| J036 | T-1LN | Square D | NQOD | A142 | 15KVA | ||||||
| J037 | LL1N | Square D | NQOD | A142 | 120/208 3P 4W | 22K | 50A 3P MCB | ||||
| J038 | NH2W | Square D | NQOD | B232 | 277/480V 3P 4W | 14K | 125A 3P MCB | NDSA, 3 | |||
| J039 | T-2NW | Square D | NQOD | B232 | 45KVA | ||||||
| J040 | NL2W SEC1 | Square D | NQOD | B232 | 120/208 3P 4W | 22K | 150A 3P MCB | ||||
| J041 | NL2W SEC2 | Square D | NQOD | B232 | 120/208 3P 4W | 22K | 100A MLO | ||||
| J042 | NH2S | Square D | NQOD | A214 | 277/480V 3P 4W | 14K | 225A 3P MCB | NDSA, 2 | |||
| J043 | T-2NS | Square D | NQOD | A214 | 15KVA | ||||||
| J044 | NL2S | Square D | NQOD | A214 | 120/208 3P 4W | 22K | 50A 3P MCB | ||||
| J045 | T-2NS1 | Square D | NQOD | A214 | 75KVA | ||||||
| J046 | NL2K | Square D | NQOD | A206 FOOD SERVICE | 120/208 3P 4W | 22K | 250A 3P MCB | SHUNT TRIP | |||
| J047 | NL2K22 | Square D | NQOD | A118 MECH RM | 120/208 3P 4W | 22K | 150A 3P MCB | ||||
| J048 | CH2S | Square D | NQOD | A214 | 277/480V 3P 4W | 14K | 30A 3P MCB | CDP, 1 | |||
| J049 | NH2N | Square D | NQOD | A235 | 277/480V 3P 4W | 14K | 90A 3P MCB | NDSA, 5 | |||
| J050 | T-2NN | Square D | NQOD | A235 | 30KVA | ||||||
| J051 | NL2N | Square D | NQOD | A235 | 120/208 3P 4W | 22K | 100A 3P MCB | SHUNT TRIP A238 | |||
| J052 | NL20T | Square D | NQOD | A238 OCC THERAPY | 120/208 3P 4W | 22K | 100A MLO | SHUNT TRIP A238 | |||
| J053 | NH3S | Square D | NQOD | A313 | 277/480V 3P 4W | 14K | 100A 3P MCB | NDSA, 3 | |||
| J054 | T-3NS | Square D | NQOD | A313 | 30KVA | ||||||
| J055 | NL3S | Square D | NQOD | A313 | 120/208 3P 4W | 22K | 100A 3P MCB | ||||
| J056 | CH3S | Square D | NQOD | A313 | 277/480V 3P 4W | 14K | 70A 3P MCB | CDP-1 | |||
| J057 | T-3CS | Square D | NQOD | A313 | 30KVA | ||||||
| J058 | CL3S | Square D | NQOD | A313 | 120/208 3P 4W | 22K | 100A 3P MCB | ||||
| J059 | CL3N | Square D | NQOD | A380 | 120/208 3P 4W | 22K | 100A 3P MCB | ||||
| PANEL | |||||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | ||||
| J060 | NH3N | Square D | QO D | A380 | 277/480V 3P 4W | 14K | 100A 3P MCB | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| J061 | T-3NN | Square D | SQ D | A380 | 45KVA | |||
| J062 | NL3N SEC 1 | Square D | QO D | A380 | 120/208 3P 4W | 22K | 150A 3P MCB | |
| J063 | NL3N SEC 2 | Square D | QO D | A380 | 120/208 3P 4W | 22K | 100A MLO | |
| J064 | T-3QN | Square D | SQ D | A380 | 45KVA | QDP,2 | ||
| J065 | QL3N | Square D | QO D | A380 | 120/208 3P 4W | 22K | 150A 3P MCB | |
| J066 | QL5N | Square D | QO D | A581 | 120/208 3P 4W | 22K | 100 MLO | |
| J067 | LH3N | Square D | QO D | A380 | 277/480V 3P 4W | 14K | 100A MLO | LDP, 1 |
| J068 | LH5N | Square D | QO D | A581 | 120/208 3P 4W | 22K | 100A MLO | |
| J069 | NH4S | Square D | QO D | A413 | 277/480V 3P 4W | 14K | 90A 3P MCB | NDSA, 4 |
| J070 | T-4NS | Square D | SQ D | A413 | 30KVA | |||
| J071 | NL4S | Square D | QO D | A413 | 120/208 3P 4W | 22K | 100A 3P MCB | |
| J072 | CH4S | Square D | QO D | A413 | 277/480V 3P 4W | 14K | 70A 3P MCB | CDP-2 |
| J073 | T-4CS | Square D | SQ D | A413 | 30KVA | |||
| J074 | CL4S | Square D | QO D | A413 | 120/208 3P 4W | 22K | 100A 3P MCB | |
| J075 | CL4N | Square D | QO D | A480 | 120/208 3P 4W | 22K | 100A MLO | |
| J076 | NH4N | Square D | QO D | A480 | 277/480V 3P 4W | 14K | 125A 3P MCB | NDSA, 7 |
| J077 | T-4NN | Square D | QO D | A480 | 45KVA | |||
| J078 | NL4N | Square D | QO D | A480 | 120/208 3P 4W | 22K | 150A 3P MCB | QDP |
| J079 | T-Q | Square D | QO D | A433 | 120/208 3P 4W | QDP | ||
| J080 | QLP4S |
vhabaybutlea: vhabaybutlea:
| New transformer and panel used for reheat units. | Square D | QO D | A433 | 120/208 3P 4W | 22K | 200A 3P MCB | |||
| J081 | NH5S | Square D | QO D | A513 | 277/480V 3P 4W | 14K | 150A 3P MCB | NDSA, 4 | |
| J082 | T-5NS | Square D | SQ D | A513 | 30KVA | ||||
| J083 | NL5S | Square D | QO D | A513 | 120/208 3P 4W | 22K | 100A 3P MCB | ||
| J084 | CH5S | Square D | QO D | A513 | 277/480V 3P 4W | 14K | 70A 3P MCB | CDP-2 | |
| J085 | NHAP | Square D | QO D | MCPB ATTIC |
vhabaybutlea: vhabaybutlea:
MOTOR CONTROL PANEL BOARD
vhabaybutlea: vhabaybutlea:
| New transformer and panel used for reheat units. | 277/480V 3P 4W | 14K | 100 MLO | ||||||
| J086 | T-5CS | Square D | SQ D | A513 | 30KVA | ||||
| J087 | CL5S | Square D | QO D | A513 | 120/208 3P 4W | 22K | 100A 3P MCB | ||
| J088 | CL5N | Square D | QO D | A581 | 120/208 3P 4W | 22K | 100A MLO | ||
| J089 | NH5N | Square D | QO D | A581 | 277/480V 3P 4W | 14K | 125A 3P MCB | NDSA, 7 | |
| J090 | T-5NN | Square D | SQ D | A581 | 45KVA | ||||
| J091 | NL5N | Square D | QO D | A581 | 120/208 3P 4W | 22K | 150A 3P MCB | ||
| J092 | ELEV WIREWAY | A601 ELEV MACH | QDP-3 |
&"-,Bold" Electrical Inventory Listing Bldg 1
B-23&40
| Bay Pines Electrical Inventory Listing Bldg. 23 & 40 | ||||||||
| Bldg 23 Substation | ||||||||
| First Floor | Manufacture | Type | Amp Frame | Amp Trip | Feeder ID | AIC | Fed from | |
| Main | ||||||||
| Breaker | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| K001 | Sq D | NW20H1 | 2000 | 2000 | Main | T-23 |
| K002 | Sq D | NW16H1 | 1600 | 1200 | 23P-2 | |
| K003 | Sq D | NW08H1 | 800 | 250 | P-2 | |
| K004 | Sq D | NW08H1 | 800 | 400 | P1-LP | |
| K005 | Sq D | NW08H1 | 800 | 400 | 1A/2A | |
| K006 | Sq D | NW08H1 | 800 | 400 | 23DP1 | |
| K007 | Sq D | NW08H1 | 800 | 800 | Spare |
| K008 | Second Floor | Sq D | 225 | 1F |
| K009 | Sq D | 100 | 1EM2 | |
| K010 | Sq D | 250 | 1E | |
| K011 | Sq D | 100 | 1G | |
| K012 | Sq D | 150 | 1EC | |
| K013 | Sq D | 250 | 1EB | |
| K014 | Sq D | 225 | 1EA |
| PANEL | ||||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES | ||
| K015 | P2 | Sq D | NQHE | 100B | ELEVATOR/CONTROLS | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| K016 | 1A | NQHE | 128 | 120/208 3P 4W | 225a PANEL | 225A MCB | ||
| K017 | 1D Left | NQHE | 128 | 120/208 3P 4W | 400A PANEL | 400A MCB | ||
| K018 | 1D Right | NQHE | 121 | 120/208 3P 4W | 400A PANEL | MLO 150 | ||
| K019 | 1B Left | NQHE | 121 | 120/208 3P 4W | 400A PANEL | 400A MCB | ||
| K020 | 1B Right | NQHE | 147 | 120/208 3P 4W | 400A PANEL | MLO | ||
| K021 | 1C Left | NQOB | 147 | 120/208 3P 4W | 225a PANEL | 125A MCB | 1B RIGHT | PROSTETICS |
| K022 | 1C Right | NQOB | 211 | 120/208 3P 4W | 225a PANEL | MLO | ||
| K023 | 2B Left | NQHB | 211 | 120/208 3P 4W | 400A PANEL | 400A MCB | ||
| K024 | 2B Right | NQHB | 211 | 120/208 3P 4W | 400A PANEL | MLO | 2B1-A SUB PANEL | |
| K025 | 2B1A | NQOD | 211 | 120/208 3P 4W | 225a PANEL | MLO | ||
| K026 | PANEL AC | NQOD | 218 | 120/208 3P 4W | 400A PANEL | MLO | ||
| K027 | PANEL 2A LEFT | NQHB | 218 | 120/208 3P 4W | 400A PANEL | 400A MCB |
| PANEL | ||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES |
| K028 | PANEL 2B RIGHT | NQHB | 218 | 120/208 3P 4W | 400A PANEL | MLO |
| K029 | P1 | I-LINE | BASEMENT | 120/208 3P 4W | 800A PANEL | 800A MCB |
| K030 | LP | NQOB | BASEMENT | 120/208 3P 4W | MLO 100A |
| Emergency Panels | ||||||||
| K031 | 1EG | SQ D | NQHB | 121 | 120/208 3P 4W | MLO 100A | Gen 40 Bldg. | Via disconnect switch |
| K032 | 1EG1 | NQOD | 121 | 120/208 3P 4W | MLO 60A | |||
| K033 | E1 | QO | BASEMENT | 120/208 3P 4W | 60A MCB | |||
| K034 | 2EF | NQO | 211 | 120/208 3P 4W | 225 MCB | Gen 40 Bldg. | ||
| K035 | 2EH | QO | 211 | 120/208 3P 4W | MLO 100A | |||
| K036 | 2EG | B10B | 211 | 120/208 3P 4W | 225 MCB | |||
| K037 | 2EG-1 | QO | 218 | 120/208 3P 4W | MLO 100A |
&"-,Bold"Bay Pines Electrical Inventory Listing Bldg. 23 & 40
B-24
| Bay Pines Electrical Inventory Listing Bldg 24 | |||||
| Bldg 24 | Emergency Generator | ||||
| ELIN | Generator 24 | Type | Model | Voltage | KW/KVA |
| L001 | Kurz & Root | E2020E203041325 | 120/208 3P 4W | 100/125 |
| MDP-24 | |||||||||
| Manufacture | Type | Amp Frame | Amp Trip | Feeder ID | Feed to | Fed from | |||
| L002 | Main | ||||||||
| Breaker | Sq D | RG1200 | 1200A | 3533KAIC | Main | T-24 | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| L003 | Sq D | LX36300 | 400A | 11250KAIC | ATS |
| L004 | Sq D | FC | 100A | 3045KAIC | Sign (front entrance) |
| L005 | Sq D | LX36400 | 400A | 12559KAIC | Panel 24N-1 |
| ATS'S BLDG 1 | |||||||||
| MANUFACTURE | SERIAL # | CAT A # | ROOM # | AIC | FED FROM NORMAL | FED FROM EM | FEED TO | ||
| L006 | ATS | ASCO 7000Series | 168606-1 | E7ATSC326OC5C | SP119-24-BP | MDP-24 |
| PANEL | ||||||||||
| ID/CKT | MANUFACTURE | TYPE | Panel Location/RM# | Electrical Data | Sym. Amps | Mains/MLO | FED FROM | FEED TO/NOTES | ||
| L007 | MDP 24 | Sq D | I-Line | SP119-24-BP | 120/208V 3P 4W | 1200A MCB | T-24 | |||
| L008 | 24N1 | Sq D | I-Line | SP119-24-BP | 120/208V 3P 4W | 400A MCB | MDP-24 | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| L009 | 24N3 | Sq D | NQOD | SP119-24-BP | 120/208V 3P 4W | 225A MCB | ||
| L010 | 24N3-A | Sq D | NQOD | SP119-24-BP | 120/208V 3P 4W | 100A MCB | ||
| L011 | AC Panel | Sq D | NQOD | Basement | 120/208V 3P 4W | 100A MCB | ||
| L012 | 24A-N2 | Sq D | NQOD | 148 | 120/208V 3P 4W | 125A MCB | ||
| L013 | 24N4 | Sq D | NQOD | 120/208V 3P 4W | 225A MCB | |||
| L014 | 24N4-A | NQOD | 120/208V 3P 4W | 100A MCB | ||||
| L015 | 24N5 | Sq D | NQOD | 120/208V 3P 4W | 100A MCB | |||
| L016 | AC Panel | Sq D | NQOD | Elevator Room | 120/208V 3P 4W | 100A MCB | ||
| L017 | 24 E4 | sq D | NQOD | 1st Floor | 120/208V 3P 4W | 225A MCB | ATS 24 | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| L018 | E5-6 | Sq D | NQOD | Gen Room | 120/208V 3P 4W | 100A MCB |
| L019 | BP | Sq D | NQOD | Basement panel | 120/208V SP 3W | 60A SP |
| L020 | 24 E5 | Sq D | NQOD | 2nd Floor | 120/208V 3P 4W | 125A MCB |
| L021 | 24 E6 | Sq D | NQOD | 3rd Floor | 120/208V 3P 4W | 150A MCB |
B-12,13,17,19,45
| Bay Pines Electrical Inventory Listing Bldg 12, 13, 17, 19, 45 | |
| M001 | T-13 TRANSFORMER - COOPER POWER SYSTEMS 3P COMPARTAMENTAL TYPE, |
PADMOUNT TRANSFORMER, 1500KVA, OIL FILLED DEAD FRONT,
LOOP FEED, 12470-208/120, 140AMP, 50KAIC
| Generator | |||||||
| Room | Type | Model | Serial # | Voltage | KW/KVA | FEED TO | |
| M002 | PERKINS ENGLAND | TPL-F3477 | U663761C | 120/208 3P 4W | 80/100 | EDP | |
| GENERATOR DISTRIBUTION | |||||||
| M003 | ECB | 100A MCB Gen Main | |||||
| M004 | EM Transformer | 480-120/208 | 75KVA | ||||
| M005 | EDP | MAGNETECK | GENCOM 1 | SER B508J901 | 200A MCB | ||
| M006 | ATS 13 | 120/208 3P 4W | |||||
| M007 | EM 13 | SQ D | QOD | 120/208 3P 4W | |||
| M008 | EDP | SQ D | QO | 13A | |||
| M009 | ATS 12 | 120/208 3P 4W | |||||
| M010 | EM 12 | SQ D | QOD 30CIRCUIT | 120/208 3P 4W | 60A MCB | ||
| M011 | ATS 19 | 120/208 3P 4W |
ATS'S BLDG PMI test results are available in electrical shop B100F123. ATS transfer test, see generator log@ each generator.
| MANUFACTURE | SERIAL # | CAT A # | ROOM # | AIC | FED FROM NORMAL | FED FROM EM | FEED TO | |||
| M012 | ATS 19 | ASCO 70 Amp | 371030- | |||||||
| 003RE | DO4ATSB30070CSOC | MDP 19N-1 | EDP | 19EM | ||||||
| M013 | ATS 12 | ASCO 70 Amp | 371030- | |||||||
| 002RE | DO4ATSB30070CS0C | 12N-1 | 12EM | |||||||
| M014 | ATS 13 | ASCO 70 Amp | 371030-001RE | DO4ATSB30070CSDC | SP 15-13-BP | MDP 19N-1 |
| Main-Normal Dist. | ||||||||
| Room # | Manufacture | Type | Amp Frame | Amp Trip | Feeder ID | Feed to | Fed from | Latest breaker PMI |
and testing results are located in electrical shop room B100F123
| M015 | SP15-13-BP | SQ D I-Line | |||||||
| M016 | Main | ||||||||
| Breaker | SQ D I-Line | NW40H | 4000 | 4000 | 100KAIC | ||||
| M017 | 1 | SQ D I-Line | FA36060 | 60 | 18KAIC | ATS 13 | |||
| M018 | 2 | SQ D I-Line | RG1000 | 1000 | 35KAIC | 13N-1 | |||
| M019 | 3 | SQ D I-Line | RG1000 | 1000 | 35KAIC | 13-N2 | |||
| M020 | 4 | SQ D I-Line | PG800 | 800 | CHILLER FEED 1 | ||||
| M021 | 5 | SQ D I-Line | PG800 | 800 | 35KAIC | CHILLER FEED 2 | |||
| M022 | 6 | SQ D I-Line | LC36400A | 400 | 12N-1 | ||||
| M023 | 7 | SQ D I-Line | LC36600 | 600 | 19N-1 | ||||
| M024 | 8 | SQ D I-Line | MG600 | 600 | 35KAIC | CHILLER FEED 3 |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.