36C24818Q0741-006.xlsx

XLSX spreadsheet 152 KB Posted

Attached to
Services, Circuit Breaker Testing Federal contract opportunity
Solicitation number
36C24818Q0741
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

36C24818Q0741 Attachment E Pricing Assistance Worksheet and all data.xlsx

View the file

Other files for this federal contract opportunity

Other files attached to Services, Circuit Breaker Testing, newest first.
File Type Posted
36C24818Q0741-012.docx DOCX document
36C24818Q0741-010.docx DOCX document
36C24818Q0741-011.pdf PDF
36C24818Q0741-005.pdf PDF
36C24818Q0741-004.pdf PDF
36C24818Q0741-000.docx DOCX document
36C24818Q0741-008.pdf PDF
36C24818Q0741-002.pdf PDF
36C24818Q0741-007.pdf PDF
36C24818Q0741-001.pdf PDF
36C24818Q0741-009.pdf PDF
36C24818Q0741-003.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pricing Assistance Worksheet

Item NumberDescription of ServicesBest Estimated QuantityUnitUnit PriceTotal Amount
_0001Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
_0001AABuilding 100, ELINS A001 through A446446JB$ - 0
_0001ABBuilding 106, ELINS B001 through B03333JB$ - 0
_0001ACBuilding 300, ELINS C001 through C0033JB$ - 0
_0001ADBuilding 107, ELINS D001 through D02121JB$ - 0
_0001AEBuilding 109, ELINS E001 through E0044JB$ - 0
_0001AFBuilding 22, ELINS F001 through F04242JB$ - 0
_0001AGBuilding 20, ELIN G001 through G01717JB$ - 0
_0001AHBuilding 103, ELIN H0011JB$ - 0
_0001AJBuilding 1, ELINS J001 through J09292JB$ - 0
_0001AKBuildings 23 and 40, ELINS K001 through K03737JB$ - 0
_0001ALBuilding 24, ELINS L001 through L02121JB$ - 0
_0001AMBuilding 12, 13, 17, 19 and 45, ELINS M001 through M04747JB$ - 0
_0001ANBuilding 102, ELINS N001 though N06161JB$ - 0
_0001APBuilding 71 and 101, ELINS P001 through P06363JB$ - 0
_0001AQBuilding 37, ELINS Q001 through Q05757JB$ - 0
_0001ARBuilding 36, ELINS R001 through R0077JB$ - 0
_0001ASBuilding 11 and 54, ELINS S001 through S01919JB$ - 0
_0001ATBuilding 2, ELINS T001 through T05252JB$ - 0
_0001AUBuilding 111, ELINS U001 through U02626JB$ - 0
_0002Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
_0002AATransformers, Attachment B, ELIN(s) A001 -A03131JB$ - 0
_0003Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
_0003AAProtective Relays, Attachment C, ELIN(s) A001 through A00671JB$ - 0
_0004Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
_0004AABuilding 111, ELINS U001 through U02626JB$ - 0
1005EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start.12Months$0.00$0.00
TOTAL$0.00
OPTION YEAR ONE
1001Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
1001AABuilding 100, ELINS A001 through A446446JB$ - 0
1001ABBuilding 106, ELINS B001 through B03333JB$ - 0
1001ACBuilding 300, ELINS C001 through C0033JB$ - 0
1001ADBuilding 107, ELINS D001 through D02121JB$ - 0
1001AEBuilding 109, ELINS E001 through E0044JB$ - 0
1001AFBuilding 22, ELINS F001 through F04242JB$ - 0
1001AGBuilding 20, ELIN G001 through G01717JB$ - 0
1001AHBuilding 103, ELIN H0011JB$ - 0
1001AJBuilding 1, ELINS J001 through J09292JB$ - 0
1001AKBuildings 23 and 40, ELINS K001 through K03737JB$ - 0
1001ALBuilding 24, ELINS L001 through L02121JB$ - 0
1001AMBuilding 12, 13, 17, 19 and 45, ELINS M001 through M04747JB$ - 0
1001ANBuilding 102, ELINS N001 though N06161JB$ - 0
1001APBuilding 71 and 101, ELINS P001 through P06363JB$ - 0
1001AQBuilding 37, ELINS Q001 through Q05757JB$ - 0
1001ARBuilding 36, ELINS R001 through R0077JB$ - 0
1001ASBuilding 11 and 54, ELINS S001 through S01919JB$ - 0
1001ATBuilding 2, ELINS T001 through T05252JB$ - 0
1001AUBuilding 111, ELINS U001 through U02626JB$ - 0
1002Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
1002AATransformers, Attachment B, ELIN(s) A001 -A03131JB$ - 0
1003Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
1003AAProtective Relays, Attachment C, ELIN(s) A001 through A00671JB$ - 0
1004Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
1004AABuilding 12, 13, 17, 19 and 45, ELINS M001 through M04747JB$ - 0
1004ABBuilding 11 and 54, ELINS S001 through S01919JB$ - 0
1004ACBuilding 103, ELIN H0011JB$ - 0
1004ADBuilding 300 ELINS C001 through C0033JB$ - 0
1004AEBuilding 37, ELINS Q001 through Q05757JB$ - 0
1004AFBuilding 102, ELINS N001 though N06161JB$ - 0
1004AGBuilding 20, ELIN G001 through G01717JB$ - 0
1004AHBuilding 71 and 101, ELINS P001 through P06363JB$ - 0
1004AJBuilding 2, ELINS T001 through T05252JB$ - 0
1004AKBuilding 107 ELINS D001 through D02121JB$ - 0
1004ALBuilding 36 ELINS R001 through R0077JB$ - 0
1005EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start.12Months$0.00$0.00
TOTAL$ - 0
OPTION YEAR TWO
2001Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
2001AABuilding 100, ELINS A001 through A446446JB$ - 0
2001ABBuilding 106, ELINS B001 through B03333JB$ - 0
2001ACBuilding 300, ELINS C001 through C0033JB$ - 0
2001ADBuilding 107, ELINS D001 through D02121JB$ - 0
2001AEBuilding 109, ELINS E001 through E0044JB$ - 0
2001AFBuilding 22, ELINS F001 through F04242JB$ - 0
2001AGBuilding 20, ELIN G001 through G01717JB$ - 0
2001AHBuilding 103, ELIN H0011JB$ - 0
2001AJBuilding 1, ELINS J001 through J09292JB$ - 0
2001AKBuildings 23 and 40, ELINS K001 through K03737JB$ - 0
2001ALBuilding 24, ELINS L001 through L02121JB$ - 0
2001AMBuilding 12, 13, 17, 19 and 45, ELINS M001 through M04747JB$ - 0
2001ANBuilding 102, ELINS N001 though N06161JB$ - 0
2001APBuilding 71 and 101, ELINS P001 through P06363JB$ - 0
2001AQBuilding 37, ELINS Q001 through Q05757JB$ - 0
2001ARBuilding 36, ELINS R001 through R0077JB$ - 0
2001ASBuilding 11 and 54, ELINS S001 through S01919JB$ - 0
2001ATBuilding 2, ELINS T001 through T05252JB$ - 0
2001AUBuilding 111, ELINS U001 through U02626JB$ - 0
2002Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
2002AATransformers, Attachment B, ELIN(s) A001 -A03131JB$ - 0
2003Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
2003AAProtective Relays, Attachment C, ELIN(s) A001 through A00671JB$ - 0
2004Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
2004AABuilding 100, ELINS A001 through A446446JB$ - 0
2004ABBuilding 106, ELINS B001 through B03333JB$ - 0
2004ACBuilding 109, ELINS E001 through E0044JB$ - 0
2005EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start.12Months$0.00$0.00
TOTAL$ - 0
OPTION YEAR THREE
3001Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
3001AABuilding 100, ELINS A001 through A446446JB$ - 0
3001ABBuilding 106, ELINS B001 through B03333JB$ - 0
3001ACBuilding 300, ELINS C001 through C0033JB$ - 0
3001ADBuilding 107, ELINS D001 through D02121JB$ - 0
3001AEBuilding 109, ELINS E001 through E0044JB$ - 0
3001AFBuilding 22, ELINS F001 through F04242JB$ - 0
3001AGBuilding 20, ELIN G001 through G01717JB$ - 0
3001AHBuilding 103, ELIN H0011JB$ - 0
3001AJBuilding 1, ELINS J001 through J09292JB$ - 0
3001AKBuildings 23 and 40, ELINS K001 through K03737JB$ - 0
3001ALBuilding 24, ELINS L001 through L02121JB$ - 0
3001AMBuilding 12, 13, 17, 19 and 45, ELINS M001 through M04747JB$ - 0
3001ANBuilding 102, ELINS N001 though N06161JB$ - 0
3001APBuilding 71 and 101, ELINS P001 through P06363JB$ - 0
3001AQBuilding 37, ELINS Q001 through Q05757JB$ - 0
3001ARBuilding 36, ELINS R001 through R0077JB$ - 0
3001ASBuilding 11 and 54, ELINS S001 through S01919JB$ - 0
3001ATBuilding 2, ELINS T001 through T05252JB$ - 0
3001AUBuilding 111, ELINS U001 through U02626JB$ - 0
3002Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
3002AATransformers, Attachment B, ELIN(s) A001 -A03131JB$ - 0
3003Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
3003AAProtective Relays, Attachment C, ELIN(s) A001 through A00671JB$ - 0
3004Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
3004AABuilding 1, ELINS J001 through J09292JB$ - 0
3004ABBuildings 23 and 40, ELINS K001 through K03737JB$ - 0
3004ACBuilding 22, ELINS F001 through F04242JB$ - 0
3004ADBuilding 24, ELINS L001 through L02121JB$ - 0
3004AEBuilding 111, ELINS U001 through U02626JB$ - 0
3005EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start.12Months$0.00$0.00
TOTAL$ - 0
OPTION YEAR FOUR
4001Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the infrared testing and inspection of electrical equipment and systems in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
4001AABuilding 100 ELINS A001 through A446446JB$ - 0
4001ABBuilding 106 ELINS B001 through B03333JB$ - 0
4001ACBuilding 300 ELINS C001 through C0033JB$ - 0
4001ADBuilding 107 ELINS D001 through D02121JB$ - 0
4001AEBuilding 109, ELINS E001 through E0044JB$ - 0
4001AFBuilding 22, ELINS F001 through F04242JB$ - 0
4001AGBuilding 20, ELIN G001 through G01717JB$ - 0
4001AHBuilding 103, ELIN H0011JB$ - 0
4001AJBuilding 1, ELINS J001 through J09292JB$ - 0
4001AKBuildings 23 and 40, ELINS K001 through K03737JB$ - 0
4001ALBuilding 24, ELINS L001 through L02121JB$ - 0
4001AMBuilding 12, 13, 17, 19 and 45, ELINS M001 through M04747JB$ - 0
4001ANBuilding 102, ELINS N001 though N06161JB$ - 0
4001APBuilding 71 and 101, ELINS P001 through P06363JB$ - 0
4001AQBuilding 37, ELINS Q001 through Q05757JB$ - 0
4001ARBuilding 36, ELINS R001 through R0077JB$ - 0
4001ASBuilding 11 and 54, ELINS S001 through S01919JB$ - 0
4001ATBuilding 2, ELINS T001 through T05252JB$ - 0
4001AUBuilding 111, ELINS U001 through U02626JB$ - 0
4002Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the transformer oil testing in accordance with the PWS for all of the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
4002AATransformers, Attachment B, ELIN(s) A001 -A03131JB$ - 0
4003Contractor shall provide all management, supervision, labor, tools and specialized equipment required to recalibrate protective relays in Building 100 in accordance with the PWS, see Exhibit Line Item Numbers (ELIN)(s) within the subCLIN below.NSPNSPNSPNSP
4003AAProtective Relays, Attachment C, ELIN(s) A001 through A00671JB$ - 0
4004Contractor shall provide all management, supervision, labor, tools and specialized equipment required to complete the breaker testing in accordance with the PWS for the equipment located on the Bay Pines campus, see Exhibit Line Item Numbers (ELIN)(s) within the subCLINS below.NSPNSPNSPNSP
4004AABuilding 12, 13, 17, 19 and 45, ELINS M001 through M04747JB$ - 0
4004ABBuilding 11 and 54, ELINS S001 through S01919JB$ - 0
4004ACBuilding 103, ELIN H0011JB$ - 0
4004ADBuilding 300 ELINS C001 through C0033JB$ - 0
4004AEBuilding 37, ELINS Q001 through Q05757JB$ - 0
4004AFBuilding 102, ELINS N001 though N06161JB$ - 0
4004AGBuilding 20, ELIN G001 through G01717JB$ - 0
4004AHBuilding 71 and 101, ELINS P001 through P06363JB$ - 0
4004AJBuilding 2, ELINS T001 through T05252JB$ - 0
4004AKBuilding 107 ELINS D001 through D02121JB$ - 0
1004ALBuilding 36 ELINS R001 through R0077JB$ - 0
4005EMERGENCY SERVICES, In Accordance with the PWS. The contractor will provide the contracting officer with a quote for repair. The fixed priced quote will contain the labor category, number of hours, and hourly cost and material costs. All Emergency Services must be approved by a Contracting Officer prior to their start.12Months$0.00$0.00
TOTAL$ - 0
GRAND TOTAL$ - 0

Transformers

ELINTransformer LocationName
A001BLDG. 1T-1
A002BLDG. 2T-2
A003BLDG. 11T-11
A004BLDG. 13T-13
A005BLDG. 20T-20
A006BLDG. 22T-22
A007BLDG. 23T-23
A008BLDG. 24T-24
A009BLDG. 36T-36
A010BLDG. 37T-37
A011BLDG. 56T-56
A012BLDG. 71T-71
A013BLDG. 100USNE
A014BLDG. 100USNW
A015BLDG. 100USEE
A016BLDG. 100USEW
A017BLDG. 100USPB
A018BLDG. 100USPA
A019BLDG. 100NDP
A020BLDG. 100MHMECH-1
A021BLDG. 100MHMECH-2
A022BLDG. 101T-101
A023BLDG. 102T-102
A024BLDG. 111MHN-1
A025BLDG. 111MHN-2
A026BLDG. 203T-203
A027BLDG. 106T-106
A028BLDG. 107T-107
A029BLDG. 109T-109
A030BLDG. 1001T-1001
A031REC INVERTERREC INVERTER

Attachment B

TRANSFORMER OIL TESTING

Protective Relays

ELINLocationRoomRelayManufacturerTypeNumber of Relays
A001Building 1001F116Reverse Power RelaysWestinghouseType CW5
A002Building 1001F115Directional OvercurrentWestinghouseType CRP-22
A003Building 1001F115Overcurrent RelaysWestinghouseType CR-26
A004Building 1001F115Overcurrent RelaysWestinghouseType CO-1142
A005Building 1001F115Ground OvercurrentWestinghouseType ITH14
A006Building 1001F115Ground OvercurrentWestinghouseType CP2

Attachment C

CALIBRATE PROTECTIVE RELAYS IN

BUILDING 100

B-100

ELIN1. SUB-STATIONS
SUB-STATIONSSIZE KVA
A001Normal (DE) Sub-Station US-N+2000 KVA
A002Normal (DE) Sub-Station US-N+2000 KVA
A003Emergency (DE) Substation US-E+2000 KVA
A004Emergency (DE) Substation US-E+2000 KVA
A005Power Substation US-PA+2000 KVA
A006Power Substation US-PB+2000 KVA
A007Power Substation Life Safety
A008Power Substation Equipment
A009Power Substation Critical
A010Power Substation Chiller (NPD) (EPD)3750 KVA
A011ASCO Paralleling Switchgear
2. GENERATORS
BREAKERSIZESUB-STATION
A012GEN #11200 AEMERGENCY
A013GEN #21200 AEMERGENCY
A014GEN #31200 AEMERGENCY
A015GEN #41200 AEMERGENCY
A016GEN #51200 AEMERGENCY
A017ATS #5800 AEMERGENCY
A018ATS #2A, 2B, 2C, 2D800 AEMERGENCY
A019ATS #6800 AEMERGENCY
A020ATS #3A, 3B, 3C, 3D800 AEMERGENCY
A021ATS #4A, 4B, 4C800 AEMERGENCY
A022ATS #1800 AEMERGENCY
A023ATS #8800 AEMERGENCY
A024ATS #7800 AEMERGENCY
A025ATS #9800 AEMERGENCY
A026ATS #10800 AEMERGENCY
A027ATS #111000 AUS - PA
3. SWITCHGEAR ROOM
BREAKERSIZESUB-STATION
A028MAIN3000 AUS-E
A029ATS #3A, 3B, 3C, 3D800 AUS-E
A030ATS #4A, 4B, 4C,800 AUS-E
A031ATS #8800 AUS-E
A032TIE-BREAKER3000 AUS-E
A033MAIN3000 AUS-E
A034ATS #1800 AUS-E
A035ATS #2A, 2B, 2C, 2D800 AUS-E
A036ATS #10800 AUS-E
A037ATS #6800 AUS-E
A038ATS #71200 AUS-E
A039X-RAY600 ADS-C
A040S.B. 1,2,3600 ADS-C
A041S.B. 7-10400 ADS-C
A042EMERGENCY CHILLER #5350 ADS-P
A043EMERGENCY CHILLER #6350 ADS-P
A044SB1-3350 ADS-P
A045MCC-PE350 ADS-Q
A046S.B. 7-10300 ADS-Q
A047S.B. 4-6600 ADS-L
A048IL-LHL200 ADS-L
A049S.B. 7-10200 ADS-L
A050S.B. 1,2,3400 ADS-L
A051S.B. 4,5,6400 ADS-L
A052MAIN3000 AUS-N
A053S.B. 4,5,62000 AUS-N
A054S.B. 7-10800 AUS-N
A055MCC-N600 AUS-N
A056MAIN3000 AUS-N
A057S.B. 1,2,32000 AUS-N
A058X-RAY600 AUS-N
A059ATS #9800 AUS-N
A060TIE-BREAKER3000 AUS-N
A061CCU-11000 AUS-PA
A062MCC-PN-A600 AUS-PA
A063CCU-21000 AUS-PA
A064CCU-41000 AUS-PB
A065MCC-PN-B600 AUS-PB
A066CCU-31000 AUS-PB
A067ATS #5800 AUS-PB
NEW CEP SwitchGear Room 1F-132
BREAKERSIZESub-Station
A068MAINMAIN4000 AMHMECH-1
A069CH-3CH-32000 AMHMECH-1
A070CH-4CH-42000 AMHMECH-1
A071CWP-1CWP-1300 AMHMECH-1
A072CWP-2CWP-2300 AMHMECH-1
A073CT-1CT-1200 AMHMECH-1
A074CT-2CT-2200 AMHMECH-1
A075S1HDN1S1HDN1600 AMHMECH-1
A076CEPHLS1CEPHLS1200 AMHMECH-1
A077CEPHDN1CEPHDN1600 AMHMECH-1
A078CHWP-1CHWP-1600 AMHMECH-1
A079CHWP-2CHWP-2600 AMHMECH-1
A080MAINMAIN4000 AMHMECH-2
A081CH-1CH-12000 AMHMECH-2
A082CH-2CH-22000 AMHMECH-2
A083CWP-3CWP-3300 AMHMECH-2
A084CT-4CT-4200 AMHMECH-2
A085FIRE PUMPFIRE PUMP1200 AMHMECH-2
A086CWP-4CWP-4300 AMHMECH-2
A087CHWP-3CHWP-3600 AMHMECH-2
A088CHWP-4CHWP-4600 AMHMECH-2
A089CT-3CT-3200 AMHMECH-2
PANELSSIZE
A090BQHL - 2150 A
A091BQHP - 2150 A
A092BQT - 230 KVA
4. ASCO ROOM
BREAKERSIZE
A09352-2-A1200A
A09452-2-B1200A
A09552-2-C1200A
A09652-2-D1200A
A09752-2-F1200A
A09852-2-G
A09952-1-A1200A
A10052-1-B1200A
A10152-1-C1200A
A10252-1-D1200A
A10352-1-F
A10452-1-G
A10552-G-61200A
A10652-G-71200A
A10752-G-81200A
A10852-G-91200A
A10952-G-101200A
A11052-G-111200A
A11152-G-121200A
PANELSSIZE
A112BQHL - 1150 A
A113BQHP - 1150 A
A114BQT - 145 KVA
5. ELEVATOR PENTHOUSE
BREAKERSIZESUB-STATION
A115MainMAIN800 AP-NHP
A116Elevator P1ELEVATOR - P1100 AP-NHP
A117Elevator P2ELEVATOR - P2100 AP-NHP
A118Elevator P3ELEVATOR - P3100 AP-NHP
A119Elevator P4ELEVATOR - S4100 AP-NHP
A120Elevator P5ELEVATOR - S5100 AP-NHP
A121Elevator P6ELEVATOR - S6100 AP-NHP
A122Elevator S7ELEVATOR - S7100 AP-NHP
A123Elevator S8ELEVATOR - S8100 AP-NHP
A124Elevator S9ELEVATOR - S9100 AP-NHP
Chillers and Bus Ducts
A125All bus ducts from switchgear thru all of building and installed breakers (90 Buses tap breakers)
A126Chiller Unit #1 Control Panel (Variable Frequency Drive)
A127Chiller Unit #2 Control Panel (Variable Frequency Drive)
A128Chiller Unit #3 Control Panel
A129Chiller Unit #4 Control Panel
6. SERVICE BAYS BUILDING 100
SERVICE BAYS 1st FloorPANELMAIN BREAKERBREAKERS
A130SB1-11BNLP -1100373 Transformers and 11 Power Panels
A131SB1-11BLNP-2MLO35
A132SB1-11BCLP3012
A133SB1-11BLQLP5030
A134SB1-11BLLPMLO9
A135SB1-11BNLP-32252
A136SB1-11BNHL-1MLO3
A137SB1-11BNHLMLO30
A138SB1-11BCHLMLO4
A139SB1-11BQHLMLO11
A140SB1-11BLHLMLO10
A141SB1-11BQLPMLO20
A142SB1-21CNLP50385 Transformers and 10 Power Panels
A143SB1-21CCLP3015
A144SB1-21CQLP25035
A145SB1-21CQHPMLO14
A146SB1-21CLLPMLO7
A147SB1-21CNHLMLO20
A148SB1-21CCHLMLO4
A149SB1-21CQHLMLO6
A150SB1-21CLHLMLO4
A151SB1-21CCLP-2MLO5
A152SB1-3lDNLP100293 Transformers and 10 Power Panels
A153SB1-3lDCLP306
A154SB1-3lDQLP25022
A155SB1-3lDLLPMLO6
A156SB1-3lDNHLMLO22
A157SB1-3lDCHLMLO4
A158SB1-3lDQHLMLO4
A159SB1-3lDLHLMLO4
A160SB1-3lDNLP-22253
A161SB1-4lENHLMLO136 Transformers, 14 Power Panels
A162SB1-4lENLP-110038
A163SB1-4lNLP-2MLO25
A164SB1-4lEQLP-112531
A165SB1-4lEQLP-27042
A166SB1-4lEQLP-320014
A167SB1-4lECLP308
A168SB1-4lECLHLMLO5
A169SB1-4lENLP-322526
A170SB1-4lECHLMLO5
A171SB1-4lEQHLMLO20
A172SB1-4lELLPMLO6
A173SB1-4lEQLP-422530
A174SB1-6lAQHLMLO4
A175SB1-6lACHL504
A176SB1-6lALHLMLO7
A177SB1-6lALLPMLO6
A178SB1-6lACLP308
A179SB1-6lAQLP3027
A180SB1-6lANLP-47041
A181SB1-6lANLP-37033
A182SB1-6lANLP-27041
A183SB1-6lANLP-17038
A184SB1-6lANHLMLO26
A185SB1-61A-QLP-222514
A186SB1-6Disc. For all NLP panels250N/A
A187SB1-7lJNlP100345 Transformers, 8 Power Panels
A188SB1-7lJCLP3018
A189SB1-7lJQLP3010
A190SB1-7lJLLP306
A191SB1-7lJNHLMLO32
A192SB1-7lJCHLMLO7
A193SB1-7lJQHLMLO7
A194SB1-7lJLHLMLO4
A195SB1-7ND-lJ-A1501
A196SB1-7ND-lJ-B1501
A197SB1-7NLP-210030
A198SB1-8lHNLP-170426 Transformers, 11 Power Panels
A199SB1-8lHNLP-27039
A200SB1-8lHNLP-37024
A201SB1-8lHCLP10040
A202SB1-8lHQLP10042
A203SB1-8lHLLP309
A204SB1-8lHNHLMLO19
A205SB1-8lHCHLMLO13
A206SB1-8lHQHLMLO12
A207SB1-8lHLHLMLO6
A208SB1-8lHQLP-222532
A209SB1-8lHQLP-315036
A210SB1-8lHCLP-222529
A211SB1-9lGNLP-1100406 Transformers, 11 Power Panels
A212SB1-9lGNLP-2MLO26
A213SB1-9lG-CLP306
A214SB1-9lG-QLP5030
A215SB1-9lG-LLP308
A216SB1-9lG-NHLMLO11
A217SB1-9lG-CHLMLO8
A218SB1-9lG-QHLMLO13
A219SB1-9lG-LHLMLO6
A220SB1-9MRI2252
A221SB1-916QLP-22259
A222SB1-10lFNLP-1MLO406 Transformers, 11 Power Panels
A223SB1-10lFNLP-210038
A224SB1-10lFCLP6038
A225SB1-10lFQLP3030
A226SB1-10lFLLP308
A227SB1-10lFNHLMLO30
A228SB1-10lFNHL-1TRANS NT-1F (70)3
A229SB1-10lFCHLMLO5
A230SB1-10lFQHLMLO14
A231SB1-10lFLHLMLO8
A232SB1-10lFQLP-222517
SERVICE BAYS 2nd FloorPANELMAIN BREAKERBREAKERS
A233SB2-12BNLP-150405 Transformers, 9 Power Panels
A234SB2-12BCLP-125035
A235SB2-12BQLP5014
A236SB2-12BLLP7013
A237SB2-12BQLP-222518
A238SB2-12BLHLMLO9
A239SB2-12BQHLMLO9
A240SB2-12BCHLMLO8
A241SB2-12BNHLMLO10
A242SB2-1U PSMLO7
A243SB2-22DNLP-150416 Transformers, 11 Power Panels
A244SB2-22DNLP -27040
A245SB2-22DNL P-35024
A246SB2-22DCLP5027
A247SB2-22DQLP-15025
A248SB2-22DLLP507
A249SB2-22DQLP-222511
A250SB2-22DCHL-222510
A251SB2-22DNHLMLO14
A252SB2-22DCHLMLO10
A253SB2-22DQHLMLO4
A254SB2-22DLHLMLO6
A255SB2-2PAC'S(UPS)MLO35
A256SB2-32FNLP-lMLO406 Transformers, 12 Power Panels
A257SB2-32FNLP-210037
A258SB2-32FCLP5026
A259SB2-32FQLP-l5039
A260SB2-32FQLP-210028
A261SB2-32FQLP-310040
A262SB2-32FQLP-45036
A263SB2-32FNHLMLO12
A264SB2-32FCHLMLO5
A265SB2-32FQHLMLO16
A266SB2-32FLHLMLO11
A267SB2-32FLLP10010
A268SB2-32F-UPS-l10032
A269SB2-32F-UPS-27024
A270SB2-32FQLP-510023
A271SB2-42ENLP-l100395 Transformers, 12 Power Panels
A272SB2-42ENLP-2MLO24
A273SB2-42ECLP306
A274SB2-42EQLP-1MLO31
A275SB2-42EQLP-210033
A276SB2-42ELLP10010
A277SB2-42ECLP-22259
A278SB2-42ENHLMLO14
A279SB2-42ECHLMLO5
A280SB2-42EQHLMLO5
A281SB2-42ELHLMLO11
A282SB2-4UPSl20031
A283SB2-4UPS2MLO13
A284SB2-52CNLP-1MLO416 Transformers, 13 Power Panels
A285SB2-52CNLP-210018
A286SB2-52CCLP-17042
A287SB2-52CCLP-27040
A288SB2-52CCLP-37013
A289SB2-52CQLP7018
A290SB2-52CLLP307
A291SB2-52CQLP-22255
A292SB2-52CNHLMLO12
A293SB2-52CCHLMLO21
A294SB2-52CQHLMLO7
A295SB2-52CLHLMLO6
A296SB2-52C???3011
A297SB2-5UPSMLO3
A298SB2-62ANLP-150295 Transformers, 9 Power Panels
A299SB2-62ACLP-l15023
A300SB2-62AQLP3012
A301SB2-62ALLP10016
A302SB2-62AQLP-22257
A303SB2-62ALHLMLO10
A304SB2-62AQHLMLO8
A305SB2-62ACHLMLO5
A306SB2-62ANHLMLO10
A307SB2-6UPS-2306
A308SB2-6UPS-122539
SERVICE BAYS 3rd FloorPANELMAIN BREAKERBREAKERS
A309SB3-13ANLP-l70423 Transformers, 12 Power Panels
A310SB3-13ANLP-27042
A311SB3-13ANLP-35026
A312SB3-13ACLP-1MLO42
A313SB3-13ACLP-215020
A314SB3-13AQLP5011
A315SB3-13ALLPMLO7
A316SB3-13ANHLMLO11
A317SB3-13ACHLMLO4
A318SB3-13AQHLMLO3
A319SB3-13ALHLMLO12
A320SB3-33BNLP-170423 Transformers, 12 Power Panels
A321SB3-33BNLP-27042
A322SB3-33BNLP-37042
A323SB3-33BNLP-47020
A324SB3-33BCLP-110040
A325SB3-33BCLP-2MLO30
A326SB3-33BQLP3017
A327SB3-33BNHLMLO14
A328SB3-33BCHLMLO4
A329SB3-33BQHLMLO4
A330SB3-33BLHLMLO12
A331SB3-33BLLPMLO4
A332SB3-43CNLP-170422 Transformers, 10 Power Panels
A333SB3-43CNLP-27042
A334SB3-43CNLP-37022
A335SB3-43CCLP-110042
A336SB3-43CQLP3014
A337SB3-43CLLPMLO7
A338SB3-43CNHLMLO7
A339SB3-43CCHLMLO4
A340SB3-43CQHLMLO4
A341SB3-43CLHLMLO11
A342SB3-63DNLP-l70423 Transformers, 12 Power Panels
A343SB3-63DNLP-27041
A344SB3-63DNLP-37020
A345SB3-63DCLP-l10042
A346SB3-63DQLP3014
A347SB3-63DLLPMLO7
A348SB3-63DNHLMLO7
A349SB3-63DCHLMLO4
A350SB3-63DQHLMLO4
A351SB3-63DLHLMLO10
SERVICE BAYS 4th FloorPANELMAIN BREAKERBREAKERS
A352SB4-14ANLP-170403 Transformers, 10 Power Panels
A353SB4-14ANLP-27042
A354SB4-14ANLP-37027
A355SB4-14ACLP-l10042
A356SB4-14AQLP3012
A357SB4-14ALLPMLO7
A358SB4-14ANHLMLO13
A359SB4-14ACHLMLO5
A360SB4-14AQHLMLO4
A361SB4-14ALHLMLO5
A362SB4-34BNLP-l70423 Transformers, 10 Power Panels
A363SB4-34BNLP-27042
A364SB4-34BNLP-37032
A365SB4-34BCLP-110041
A366SB4-34BQLP10018
A367SB4-34BLLPMLO7
A368SB4-34BNHLMLO13
A369SB4-34BCHLMLO4
A370SB4-34BQHLMLO4
A371SB4-34BLHLMLO6
A372SB4-44CNLP-l70423 Transformers, 10 Power Panels
A373SB4-44CNLP-27041
A374SB4-44CNLP-37019
A375SB4-44CCLP-110041
A376SB4-44CQLP10034
A377SB4-44CLLPMLO7
A378SB4-44CNHLMLO8
A379SB4-44CCHLMLO4
A380SB4-44CQHLMLO5
A381SB4-44CLHLMLO4
A382SB4-64DNLP-l70423 Transformers, 10 Power Panels
A383SB4-64DNLP-27042
A384SB4-64DNLP-37020
A385SB4-64DCLP-110041
A386SB4-64DQLP3012
A387SB4-64DLLPMLO7
A388SB4-64DNHLMLO8
A389SB4-64DCHLMLO4
A390SB4-64DQHLMLO4
A391SB4-64DLHLMLO4
A392SB4-64DCLP-210022
A393SB4-65ANLP-17042
SERVICE BAYS 5th FloorPANELMAIN BREAKERBREAKERS
A394SB5-15ANLP-270423 Transformers, 10 Power Panels
A395SB5-15ANLP-37027
A396SB5-15ACLP-110042
A397SB5-15AQLP3013
A398SB5-15ALLPMLO7
A399SB5-15ANHLMLO12
A400SB5-15ACHLMLO5
A401SB5-15AQHLMLO6
A402SB5-15ALHLMLO6
A403SB5-35BNLP-170423 Transformers, 10 Power Panels
A404SB5-3SBNLP-27042
A405SB5-3SBNLP-37030
A406SB5-3SBCLP-110042
A407SB5-3SBQLP3017
A408SB5-3SBLLPMLO7
A409SB5-3SBLHLMLO6
A410SB5-3SBQHLMLO11
A411SB5-3SBCHLMLO4
A412SB5-35BNHLMLO13
A413SB5-45CNLP-170423 Transformers, 10 Power Panels
A414SB5-45CNLP-27042
A415SB5-45CNLP-37018
A416SB5-45CCLP-110042
A417SB5-45CQLP3015
A418SB5-45CLLPMLO7
A419SB5-45CLHLMLO4
A420SB5-45CQHLMLO8
A421SB5-45CCHLMLO4
A422SB5-45CNHLMLO8
A423SB5-45CNLP-420015
A424SB5-65DNLP-170413 Transformers, 10 Power Panels
A425SB5-65DNLP-27040
A426SB5-65DNLP-37020
A427SB5-65DCLP-110042
A428SB5-65DQLP3016
A429SB5-65DLLPMLO7
A430SB5-65DLHLMLO4
A431SB5-65DQHLMLO5
A432SB5-65DCHLMLO4
A433SB5-65DNHLMLO7
A434Room 1B1041 Power Panel
A435Room 1A1031 Power Panel
A436Room 1C1071 Power Panel
A437Room 1F1101 Power Panel
A438Room 1F1111 Power Panel
A439Room 1F1131 Power Panel
A440Room 1F1221 Power Panel
A441Room 1F1231 Power Panel
A442Room 1F1241 Power Panel
A443Room 1F1001 Power Panel, 2 Transformers
A444Room 1F1146 Power Panels, 3 Transformers
A445Room 1F1151 Power Panel
A446Room 1F1161 Power Panel, 1 Transformer

&"-,Bold"ELECTRICAL INVENTORY BUILDING 100

B-106

1. PANELS / ROOMS 1G -143
ELINPANEL IDSIZEMAIN
B001MDP1200AMCB
B002MDP400 AFeeder breakers
B003MDP400 AFeeder breakers
B004MDP250 AFeeder breakers
B005MDP150 AFeeder breakers
B006MDP125 AFeeder breakers
B007MDP125 AFeeder breakers
B008MDP100 AFeeder breakers
B009MDP60 AFeeder breakers
B010MDP60 AFeeder breakers
PANEL IDSIZEMAINBREAKERS
B0111NHLL100 AMLO42
B0121QHLM225 AMLO42
B0131NLPG1300 AMCB24
B0141NLPG2225 AMLO42
B0151LLPG100 AMLO30
2. PANELS / ROOMS 1G -143B
PANEL IDSIZEMAINBREAKERS
B0161NLPG3225 AMLO42
B0171NLPG4225 AMLO42
3. PANELS / ROOMS 2G -168
PANEL IDSIZEMAIN
B018E- MDP300 AMCB
B019E- MDP150 AFeeder breakers
B020E- MDP100 AFeeder breakers
B0212NLPG300 AMCB20
B0222CLPG1300 AMCB42
B0232QLPM60 AMCB42
B0242LLPG100 AMCB30
B0252QHLM1400 AMLO30
B0262NHLL100 AMLO42
B0272LHLG125 AMLO30
B0282NLPG1225 AMLO42
B0292QHLM2125 AMLO30
B0302CHLG250 AMLO42
5. PANELS / ROOMS 2G - 146
PANEL IDSIZEMAINBREAKERS
B0312CLPG2225 AMLO42
6. PANELS / ROOMS 2G - 145
PANEL IDSIZEMAINBREAKERS
B0322CLPG3225 AMLO42
B0332NLPG2225 AMLO42

&"-,Bold"ELECTRICAL INVENTORY BUILDING 106

B-300

ELINPANEL IDSIZEMAINBREAKERS
C001NLP-A-300300 AMCB42
C002NLP-B-300400 AMLO30
C003EDP-300125 AMLO16

&"-,Bold"ELECTRICAL INVENTORY BUILDING 300

B-107

Electrical Inventory Building 107
Bldg 107 ROC 1
TransformerT107ABB
MDP
ELINBldg 107ManufactureTypeAmp FrameAmp TripFeeder IDAICFed from
D001Sq DI-Line12001200T107Latest breaker PMI

and testing results are located in electrical shop room B100F123

D002Main
BreakerSq DPowerPact
RK120012001200T107
D003Sq DPowerPact
HJA36150HJ150150Linac 1
D004Sq DPowerPact
HJA36150HJ150150Linac 2
D005Sq DPowerPact
HJA36060HJ06060Surge Protection
D006Sq DPowerPact
JJA36175JJ175175TX-NLP
D007Sq DPowerPact
JJA36225JJ225225NHL2, NHL3
D008Sq DPowerPact
HJA36125HJ150125CT Scan
D009Sq DPowerPact
HJA36100HJ150100NHL1
D010Sq DPowerPact
HJA36015HJ06015Emon Meter
D011Sq DPowerPact
HJA36040HJ06040Linac Chiller 1
D012Sq DPowerPact
HJA36040HJ06040Linac Chiller 2

D013 Transformer Sq D TX-NLP 480 to 120/208 3P 112.5KVA Cat # EE112T3HCU

PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
D014NLP-1Sq DNQSP126-107-BP120/208 3P 4W400A MCBTX-NLP
D015NLP-2Sq DNQSP126-107-BP120/208 3P 4W400A MLOTX-NLP
D016NLP-2ASq DNQSP126-107-BP120/208 3P 4W100A MLONLP-2
D017NLP-3Sq DNQSP126-107-BP120/208 3P 4W40A MLONLP-2
D018NHL1Sq DNFSP126-107-BP277/480 3P 4W100A MLOMDP
D019NHL2Sq DNFSP126-107-BP277/480 3P 4W225A MLOMDP
D020NHL3Sq DNFSP126-107-BP277/480 3P 4W225A MLOMDP
D021Lighting Relay
PanelILC Intelligent
Lighting ControlApprentice
2SP126-107-BP277/480 3P 4WWHL1Lights

&"-,Bold"Electrical Inventory Building 107

B-109

Electrical Inventory Building 109
Bldg 109 Parking Garage
ELINTransformer
E001T-10912,470V 3P--480/277 3P 4W
TransformerSq D
E002H-1480/277 3P 3W--208/120 3P 4W
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTESLatest breaker PMI

and testing results are located in electrical shop room B100F123

E003HSq DSecond Floor
Electrical Room277/480 3P 4W400A MCBT-10942 Circuits
E004LSq DSecond Floor
Electrical Room120/208 3P 4W400A MLO42 Circuits

&"-,Bold"Electrical Inventory Building 109

B-22

ELINSub Station
F001TransformerT-22500 KVA
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
F002Main1600A
F003NHIS150A
F004NH3S150A
F005NHIN150A
F006NH3N150A
F007EMDP250A
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
F008Bldg 22
F009NHINRoom 13070AMCBLatest breaker PMI

and testing results are located in electrical shop room B100F123

F010ELINRoom 13030AMCB
F011NLIN-1Room 13050AMCB
F012NLIN-2Room 130125AMCB
F013EHINRoom 13030AMCB
F014NHISRoom 11090AMCB
F015NLIS-1Room 110100AMCB
F016NLIS-2Room 110100AMCB
F017LHISRoom 11030AMCB
F018LLISRoom 11030AMCB
F019EL2NRoom 20930AMCB
F020EL3N-1Room 34430AMCB
F021NH3SRoom 30970AMCB
F022NL3S-1Room 30950AMCB
F023NL3S-2Room 309100AMCB
F024LH3SRoom 309100AMLO
F025NH4NRoom 43570AMCB
F026NL4N-1Room 43550AMCB
F027NL4N-2Room 435100AMCB
F028NH2NRoom 21090AMCB
F029NL2NRoom 210100AMCB
F030EH2NRoom 21030AMCB
F031NH2SRoom 20990AMCB
F032NL2S-1Room 209100AMCB
F033NL2S-2Room 209100AMCB
F034NL3N-1Room 344100AMCB
F035EL3N-2Room 344100AMCB
F036EH3NRoom 34430AMCB
F037NH3NRoom 34490AMCB
F038EH4NRoom 43570AMCB
F039EL4NRoom 43570AMCB
F040NH4SRoom 40750AMCB
F041NL4S-1Room 40750AMCB
F042NL4S-2Room 407100AMCB

&"-,Bold"Electrical Inventory Building 22

B-20

Electrical Inventory Building 20
Bldg 20, Post Office, Education
ELIN
G001TransformerT-2012,470V--120/208V 3P 4WTwo breakers are

located in Stainless Steel enclosure, located outside

ManufactureTypeAmp FrameAmp TripFeeder IDAICFed from
G002Feeder Breaker250AT-20
G003Feeder Breaker400AT-20
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES

G004 MDP 120/208 3P 4W Latest breaker PMI and testing results are located in electrical shop room B100F123

G005MDP-1400A
G006MDP-2400A
G007MDP-3400A
G008MDP-4400A
G009MDP-5400A
G010MDP-6400A
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
G011Panel 20120/208 3P 4W100MLO
G012Panel B120/208 3P 4W225MCB
G013Panel D120/208 3P 4W225MCB
G014Power Panel120/208 3P 4W
G015Power Panel120/208 3P 4W
G016Power Panel120/208 3P 4W
G017Power Panel120/208 3P 4W

&"-,Bold"Electrical Inventory Building 20

B-103

Electrical Inventory Building 103
Pump House
ELINPANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
H001MDPSq DN/A120/208 4 wireMCB 300ABuilding 11 MDPLatest breaker PMI

and testing results are located in electrical shop room B100F123

B-1

Electrical Inventory Listing Bldg 1
ELINRoom B114TypeModelSerial #VoltageKW/KVA
J001Cummings DieselAP-765DC33107027480/277 3P 4W600/750Notes: Feeds Bldg
1 & 22PMI and testing results are located in the electric shop B-100, room 1F123
Sub
stationNDSA SUB-STATION

Room # B114 Manufacture Type Amp Frame Amp Trip Feeder ID room B114 Fed from

J002Main
BreakerWestinghouse/Sq DDS-63232003200NDSA
J0031Westinghouse/Sq DDS-206800300NH1S,NDSA
J0042Westinghouse/Sq DDS-206800300NH2S, NH3SNDSA
J0053Westinghouse/Sq DDS-206800300NH1W, NH3SNDSA
J0064Westinghouse/Sq DDS-206800300NH4S, NH5S, NHAPNDSA
J0075Westinghouse/Sq DDS-206800300NH1N, NH2NNDSA
J0086Westinghouse/Sq DDS-206800300ATS2, CDPNDSA
J0097Westinghouse/Sq DDS-206800300NH3N, NH4N, NH5NNDSA
J0108Westinghouse/Sq DDS-206800150ATS1, LDPNDSA
J0119Westinghouse/Sq DDS-206800800ATS3, QDPNDSA
J01210Westinghouse/Sq DDS-206800150SPNDSA
J01311Westinghouse/Sq DDS-206800150SPNDSA
12EMPTYNDSA

PMI test results are available in electrical shop B100F123. ATS transfer test, see generator log@ each generator.

ATS'S BLDG 1MANUFACTURESERIAL #CAT A #ROOM #AICFED FROM NORMALFED FROM EMFEED TO
J014ATS 1ASCO, ATS # 1921374C9403215099XCB11425KNDSA - 8EGDP-1LDP
J015ATS 2ASCO, ATS # 2952217C940326099XCB11425KNDSA - 6EGDP-2CDP
J016ATS 3ASCO, ATS # 3921377C940380099XCB11425KNDSA - 9EGDP-3QDP
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
J017EGDPSEE GENERATORB115BLDG 1 GENLatest breaker PMI

and testing results are located in electrical shop room B100F123

J018LDPSquare DI-LineB114277/480V 3P 4W225A MLONDSA, 8EQDP,1
J019CDPSquare DI-LineB114277/480V 3P 4W400A MLONDSA, 6EQDP, 2
J020QDPSquare DI-LineB114277/480V 3P 4W800A MLONDSA, 9EQDP, 3
J021QH1WSquare DI-LineB114277/480V 3P 4W400A MLOQDP-5
J022T-1QWSquare DSQ DB11415KVA
J023QLIWSquare DNQODB114120/208 3P 4W50A 3P MCB
J024NH1WSquare DNQODB116277/480V 3P 4W14K175A 3P MCBNDSA, 3
J025T-1NWSquare DNQODB11630KVA
J026NL1WSquare DNQODB116120/208 3P 4W22K100A 3P MCB
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROM
J018LH1WSquare DNQODB116277/480V 3P 4W14K100A MLOLDP, 3Latest breaker PMI

and testing results are located in electrical shop room B100F123

J019T-1LSSquare DNQODB1166KVALH1W
J020LL1WSquare DNQODB116120/208 3P 4W22K30A 3P MCBLH1W
J021NH1SSquare DNQODA121277/480V 3P 4W14K400 MLONDSA, 1
J022NHMRSquare DNQODA109 MECH277/480V 3P 4W14K100A MLO
J023T-INSSquare DSQ DA121112.5KVA
J024NLDPSquare DNQODA121120/208 3P 4W22K400A 3P MCB
J025NLIS SEC1Square DNQODA121120/208 3P 4W14K225 MLO
J026NLIS SEC2Square DNQODA121120/208 3P 4W22K100A MLO
J027NLIKSquare DNQODA118120/208 3P 4W22K225A MLOSHUNT TRIP FROM

A107 KITCHEN

J028NLISSSquare DNQODA121120/208 3P 4W22K30A 3P MCBI.G.
J029T-1QMSquare DNQODA11845KVAQDP, 1
J030QL1KSquare DNQODA118120/208 3P 4W22K100A 3P MCBQDP, 1
J031QLI1K1Square DNQODA118120/208 3P 4W22K40A 3P MCBQDP,1
J032NH1NSquare DNQODA142277/480V 3P 4W14K100A 3P MCBNDSA, 5
J033T-1NNSquare DNQODA14230KVA
J034NL1NSquare DNQODA142120/208 3P 4W22K100A 3P MCB
J035LH1NSquare DNQODA142277/480V 3P 4W14K100A MLO
J036T-1LNSquare DNQODA14215KVA
J037LL1NSquare DNQODA142120/208 3P 4W22K50A 3P MCB
J038NH2WSquare DNQODB232277/480V 3P 4W14K125A 3P MCBNDSA, 3
J039T-2NWSquare DNQODB23245KVA
J040NL2W SEC1Square DNQODB232120/208 3P 4W22K150A 3P MCB
J041NL2W SEC2Square DNQODB232120/208 3P 4W22K100A MLO
J042NH2SSquare DNQODA214277/480V 3P 4W14K225A 3P MCBNDSA, 2
J043T-2NSSquare DNQODA21415KVA
J044NL2SSquare DNQODA214120/208 3P 4W22K50A 3P MCB
J045T-2NS1Square DNQODA21475KVA
J046NL2KSquare DNQODA206 FOOD SERVICE120/208 3P 4W22K250A 3P MCBSHUNT TRIP
J047NL2K22Square DNQODA118 MECH RM120/208 3P 4W22K150A 3P MCB
J048CH2SSquare DNQODA214277/480V 3P 4W14K30A 3P MCBCDP, 1
J049NH2NSquare DNQODA235277/480V 3P 4W14K90A 3P MCBNDSA, 5
J050T-2NNSquare DNQODA23530KVA
J051NL2NSquare DNQODA235120/208 3P 4W22K100A 3P MCBSHUNT TRIP A238
J052NL20TSquare DNQODA238 OCC THERAPY120/208 3P 4W22K100A MLOSHUNT TRIP A238
J053NH3SSquare DNQODA313277/480V 3P 4W14K100A 3P MCBNDSA, 3
J054T-3NSSquare DNQODA31330KVA
J055NL3SSquare DNQODA313120/208 3P 4W22K100A 3P MCB
J056CH3SSquare DNQODA313277/480V 3P 4W14K70A 3P MCBCDP-1
J057T-3CSSquare DNQODA31330KVA
J058CL3SSquare DNQODA313120/208 3P 4W22K100A 3P MCB
J059CL3NSquare DNQODA380120/208 3P 4W22K100A 3P MCB
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROM
J060NH3NSquare DQO DA380277/480V 3P 4W14K100A 3P MCBLatest breaker PMI

and testing results are located in electrical shop room B100F123

J061T-3NNSquare DSQ DA38045KVA
J062NL3N SEC 1Square DQO DA380120/208 3P 4W22K150A 3P MCB
J063NL3N SEC 2Square DQO DA380120/208 3P 4W22K100A MLO
J064T-3QNSquare DSQ DA38045KVAQDP,2
J065QL3NSquare DQO DA380120/208 3P 4W22K150A 3P MCB
J066QL5NSquare DQO DA581120/208 3P 4W22K100 MLO
J067LH3NSquare DQO DA380277/480V 3P 4W14K100A MLOLDP, 1
J068LH5NSquare DQO DA581120/208 3P 4W22K100A MLO
J069NH4SSquare DQO DA413277/480V 3P 4W14K90A 3P MCBNDSA, 4
J070T-4NSSquare DSQ DA41330KVA
J071NL4SSquare DQO DA413120/208 3P 4W22K100A 3P MCB
J072CH4SSquare DQO DA413277/480V 3P 4W14K70A 3P MCBCDP-2
J073T-4CSSquare DSQ DA41330KVA
J074CL4SSquare DQO DA413120/208 3P 4W22K100A 3P MCB
J075CL4NSquare DQO DA480120/208 3P 4W22K100A MLO
J076NH4NSquare DQO DA480277/480V 3P 4W14K125A 3P MCBNDSA, 7
J077T-4NNSquare DQO DA48045KVA
J078NL4NSquare DQO DA480120/208 3P 4W22K150A 3P MCBQDP
J079T-QSquare DQO DA433120/208 3P 4WQDP
J080QLP4S

vhabaybutlea: vhabaybutlea:

New transformer and panel used for reheat units.Square DQO DA433120/208 3P 4W22K200A 3P MCB
J081NH5SSquare DQO DA513277/480V 3P 4W14K150A 3P MCBNDSA, 4
J082T-5NSSquare DSQ DA51330KVA
J083NL5SSquare DQO DA513120/208 3P 4W22K100A 3P MCB
J084CH5SSquare DQO DA513277/480V 3P 4W14K70A 3P MCBCDP-2
J085NHAPSquare DQO DMCPB ATTIC

vhabaybutlea: vhabaybutlea:

MOTOR CONTROL PANEL BOARD

vhabaybutlea: vhabaybutlea:

New transformer and panel used for reheat units.277/480V 3P 4W14K100 MLO
J086T-5CSSquare DSQ DA51330KVA
J087CL5SSquare DQO DA513120/208 3P 4W22K100A 3P MCB
J088CL5NSquare DQO DA581120/208 3P 4W22K100A MLO
J089NH5NSquare DQO DA581277/480V 3P 4W14K125A 3P MCBNDSA, 7
J090T-5NNSquare DSQ DA58145KVA
J091NL5NSquare DQO DA581120/208 3P 4W22K150A 3P MCB
J092ELEV WIREWAYA601 ELEV MACHQDP-3

&"-,Bold" Electrical Inventory Listing Bldg 1

B-23&40

Bay Pines Electrical Inventory Listing Bldg. 23 & 40
Bldg 23 Substation
First FloorManufactureTypeAmp FrameAmp TripFeeder IDAICFed from
Main
BreakerLatest breaker PMI

and testing results are located in electrical shop room B100F123

K001Sq DNW20H120002000MainT-23
K002Sq DNW16H11600120023P-2
K003Sq DNW08H1800250P-2
K004Sq DNW08H1800400P1-LP
K005Sq DNW08H18004001A/2A
K006Sq DNW08H180040023DP1
K007Sq DNW08H1800800Spare
K008Second FloorSq D2251F
K009Sq D1001EM2
K010Sq D2501E
K011Sq D1001G
K012Sq D1501EC
K013Sq D2501EB
K014Sq D2251EA
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
K015P2Sq DNQHE100BELEVATOR/CONTROLSLatest breaker PMI

and testing results are located in electrical shop room B100F123

K0161ANQHE128120/208 3P 4W225a PANEL225A MCB
K0171D LeftNQHE128120/208 3P 4W400A PANEL400A MCB
K0181D RightNQHE121120/208 3P 4W400A PANELMLO 150
K0191B LeftNQHE121120/208 3P 4W400A PANEL400A MCB
K0201B RightNQHE147120/208 3P 4W400A PANELMLO
K0211C LeftNQOB147120/208 3P 4W225a PANEL125A MCB1B RIGHTPROSTETICS
K0221C RightNQOB211120/208 3P 4W225a PANELMLO
K0232B LeftNQHB211120/208 3P 4W400A PANEL400A MCB
K0242B RightNQHB211120/208 3P 4W400A PANELMLO2B1-A SUB PANEL
K0252B1ANQOD211120/208 3P 4W225a PANELMLO
K026PANEL ACNQOD218120/208 3P 4W400A PANELMLO
K027PANEL 2A LEFTNQHB218120/208 3P 4W400A PANEL400A MCB
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
K028PANEL 2B RIGHTNQHB218120/208 3P 4W400A PANELMLO
K029P1I-LINEBASEMENT120/208 3P 4W800A PANEL800A MCB
K030LPNQOBBASEMENT120/208 3P 4WMLO 100A
Emergency Panels
K0311EGSQ DNQHB121120/208 3P 4WMLO 100AGen 40 Bldg.Via disconnect switch
K0321EG1NQOD121120/208 3P 4WMLO 60A
K033E1QOBASEMENT120/208 3P 4W60A MCB
K0342EFNQO211120/208 3P 4W225 MCBGen 40 Bldg.
K0352EHQO211120/208 3P 4WMLO 100A
K0362EGB10B211120/208 3P 4W225 MCB
K0372EG-1QO218120/208 3P 4WMLO 100A

&"-,Bold"Bay Pines Electrical Inventory Listing Bldg. 23 & 40

B-24

Bay Pines Electrical Inventory Listing Bldg 24
Bldg 24Emergency Generator
ELINGenerator 24TypeModelVoltageKW/KVA
L001Kurz & RootE2020E203041325120/208 3P 4W100/125
MDP-24
ManufactureTypeAmp FrameAmp TripFeeder IDFeed toFed from
L002Main
BreakerSq DRG12001200A3533KAICMainT-24Latest breaker PMI

and testing results are located in electrical shop room B100F123

L003Sq DLX36300400A11250KAICATS
L004Sq DFC100A3045KAICSign (front entrance)
L005Sq DLX36400400A12559KAICPanel 24N-1
ATS'S BLDG 1
MANUFACTURESERIAL #CAT A #ROOM #AICFED FROM NORMALFED FROM EMFEED TO
L006ATSASCO 7000Series168606-1E7ATSC326OC5CSP119-24-BPMDP-24
PANEL
ID/CKTMANUFACTURETYPEPanel Location/RM#Electrical DataSym. AmpsMains/MLOFED FROMFEED TO/NOTES
L007MDP 24Sq DI-LineSP119-24-BP120/208V 3P 4W1200A MCBT-24
L00824N1Sq DI-LineSP119-24-BP120/208V 3P 4W400A MCBMDP-24Latest breaker PMI

and testing results are located in electrical shop room B100F123

L00924N3Sq DNQODSP119-24-BP120/208V 3P 4W225A MCB
L01024N3-ASq DNQODSP119-24-BP120/208V 3P 4W100A MCB
L011AC PanelSq DNQODBasement120/208V 3P 4W100A MCB
L01224A-N2Sq DNQOD148120/208V 3P 4W125A MCB
L01324N4Sq DNQOD120/208V 3P 4W225A MCB
L01424N4-ANQOD120/208V 3P 4W100A MCB
L01524N5Sq DNQOD120/208V 3P 4W100A MCB
L016AC PanelSq DNQODElevator Room120/208V 3P 4W100A MCB
L01724 E4sq DNQOD1st Floor120/208V 3P 4W225A MCBATS 24Latest breaker PMI

and testing results are located in electrical shop room B100F123

L018E5-6Sq DNQODGen Room120/208V 3P 4W100A MCB
L019BPSq DNQODBasement panel120/208V SP 3W60A SP
L02024 E5Sq DNQOD2nd Floor120/208V 3P 4W125A MCB
L02124 E6Sq DNQOD3rd Floor120/208V 3P 4W150A MCB

B-12,13,17,19,45

Bay Pines Electrical Inventory Listing Bldg 12, 13, 17, 19, 45
M001T-13 TRANSFORMER - COOPER POWER SYSTEMS 3P COMPARTAMENTAL TYPE,

PADMOUNT TRANSFORMER, 1500KVA, OIL FILLED DEAD FRONT,

LOOP FEED, 12470-208/120, 140AMP, 50KAIC

Generator
RoomTypeModelSerial #VoltageKW/KVAFEED TO
M002PERKINS ENGLANDTPL-F3477U663761C120/208 3P 4W80/100EDP
GENERATOR DISTRIBUTION
M003ECB100A MCB Gen Main
M004EM Transformer480-120/20875KVA
M005EDPMAGNETECKGENCOM 1SER B508J901200A MCB
M006ATS 13120/208 3P 4W
M007EM 13SQ DQOD120/208 3P 4W
M008EDPSQ DQO13A
M009ATS 12120/208 3P 4W
M010EM 12SQ DQOD 30CIRCUIT120/208 3P 4W60A MCB
M011ATS 19120/208 3P 4W

ATS'S BLDG PMI test results are available in electrical shop B100F123. ATS transfer test, see generator log@ each generator.

MANUFACTURESERIAL #CAT A #ROOM #AICFED FROM NORMALFED FROM EMFEED TO
M012ATS 19ASCO 70 Amp371030-
003REDO4ATSB30070CSOCMDP 19N-1EDP19EM
M013ATS 12ASCO 70 Amp371030-
002REDO4ATSB30070CS0C12N-112EM
M014ATS 13ASCO 70 Amp371030-001REDO4ATSB30070CSDCSP 15-13-BPMDP 19N-1
Main-Normal Dist.
Room #ManufactureTypeAmp FrameAmp TripFeeder IDFeed toFed fromLatest breaker PMI

and testing results are located in electrical shop room B100F123

M015SP15-13-BPSQ D I-Line
M016Main
BreakerSQ D I-LineNW40H40004000100KAIC
M0171SQ D I-LineFA360606018KAICATS 13
M0182SQ D I-LineRG1000100035KAIC13N-1
M0193SQ D I-LineRG1000100035KAIC13-N2
M0204SQ D I-LinePG800800CHILLER FEED 1
M0215SQ D I-LinePG80080035KAICCHILLER FEED 2
M0226SQ D I-LineLC36400A40012N-1
M0237SQ D I-LineLC3660060019N-1
M0248SQ D I-LineMG60060035KAICCHILLER FEED 3