Key modifications include: removal of requirements for door replacement and sliding glass door installation; addition of wall patching and Level 5 drywall finish requirements for all four walls in Room B185; painting requirements with primer and two finish coats; replacement of five 18"x18" vinyl floor tiles (with VA potentially providing matching attic stock); installation of 40 feet of 4-inch vinyl cove base; increase in electrical requirements from one to two normal duplex receptacles and one to two emergency duplex receptacles; addition of ACM and Lead testing requirements from November 2024 with provisions for handling suspect materials; and relocation of a data port/outlet from the south wall to the north wall. The document confirms that existing floor tile and cove base were tested and found to be non-ACM, with an IH report to be provided.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
534-23-513 Med Gas SOW changes
In paragraph A-2 delete removal of existing door and delete installation of sliding glass door. Contractor to patch all holes in all 4 walls of room B185 and provide a level 5 drywall finish. Paint (primer with 2 finish coats) all walls in Rm B185 to match existing color. COR can assist contractor in obtaining paint colors. Contractor to demo five 18” x 18” vinyl floor tile and furnish/replace with like kind. VA has attic stock of matching floor tile and can furnish with appropriate credit of material cost back to government. If government provides floor tile the contractor is responsible for all materials needed to install floor tile. Demolish 40 feet of 4 inch vinyl cove base. Furnish/install 40 feet of 4 inch vinyl cove base to match existing. Existing floor tile and cove base were tested for ACM and found to be non-ACM. IH report will be provided.
In paragraph A-3 increase number of Normal duplex receptacles from one to two and increase number of emergency duplex receptacles from one to two. All other requirements of this paragraph remain.
In paragraph A5 add that project area was tested for ACM and Lead in Nov 2024. VA to provide test results. If contractor suspects any additional materials not included in this report contain ACM the suspect material should be treated as ACM until proven otherwise by sampling and testing per SC DES regulations.
In paragraph A-7 add the following requirement: Contractor to relocate the data port/outlet located on south wall to location on north wall as directed by VA. All other requirements of this paragraph remain.