36C24724Q0777.docx
DOCX document 29 KB Posted
- Solicitation number
- 36C24724Q0777
About this file
This document is a Sources Sought Notice from the Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 7, for Project 508-24-115 - Upgrade Transformer Bldg. 135 at the Atlanta VA Health Care System.
The VA is conducting market research to determine the availability and capability of Service-Disabled Veteran Owned Small Businesses (SDVOSB) to perform the required work, which includes installing PVC conduit, removing and replacing a customer-owned transformer, and making secondary terminations. The NAICS code is 238210. Interested vendors should submit a capability statement not exceeding 5 pages by 1:00 PM EST on June 14, 2024. A site visit is scheduled for June 10-14, 2024 from 9:00-11:00 AM. This is not a formal solicitation, and the Government will use the information for market research purposes only.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 GA Power Service Manual.pdf | ||
| Attachment 1 Statement of Work.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
| SUBJECT* |
| 508-24-115 | Upgrade Electrical Transformer Bldg. 135 (VA-24-00064485) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 30009 |
| SOLICITATION NUMBER* |
| 36C24724Q0777 |
| RESPONSE DATE/TIME/ZONE |
| 06-14-2024 1:00PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 45 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| Y1BG |
| NAICS CODE* |
| 238210 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
VISN 7 Network Contracting Office 3700 Crestwood Pkwy - suite 310
Duluth, GA 30096
POINT OF CONTACT*
Contract Specialist Kimberly Devlin kimberly.devlin@va.gov 706-627-2796
PLACE OF PERFORMANCE
| ADDRESS |
| Atlanta VA Health Care System |
1670 Clairmont Rd.
| CITY, STATE |
| Decatur GA |
| POSTAL CODE |
| 30033 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov |
| URL DESCRIPTION |
| Department of Veteran Affairs |
| AGENCY CONTACT’S EMAIL ADDRESS |
| kimberly.devlin@va.gov |
| EMAIL DESCRIPTION |
| Contract Specialist |
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
The purpose of this correspondence is for Market Research and Information purpose ONLY at this time and shall not be construed as a solicitation or as an obligation on the behalf of the Department of Veteran Affairs.
The Department of Veteran Affairs, Veterans Health Administration (VHA), Network Contracting Office (NCO) 7 is conducting market research to determine the availability and capability of Service-Disabled Veteran Owned Small Businesses (SDVOSB) for Project: 508-24-115 Upgrade Transformer Bldg. 135 at the Atlanta VA Health Care System located at 1670 Clairmont Rd, Decatur, GA 30033.
Project Description The contractor shall furnish all labor, tools, equipment personnel, supervision, materials, supplies and transportation necessary to perform secondary work on a relocated transformer for building 135 at the Ft. Macpherson location as shown in the associated drawings within the Atlanta VA Health Care System. Work includes installation of 2 runs of 4” PVC conduit 120’ from the new transformer to the new secondary terminating cabinet location near the existing customer owned transformer by open trench. Installation of 2 runs of 4” PVC conduit 120’ from the new transformer to the new secondary terminating cabinet location near the existing customer owned transformer by open trench, saw cut concrete slab if necessary to stub up new conduits with the existing secondary conduits, provide and install (1) run of 500UQA CU through each conduit, de-energize and remove existing customer owned radial feed transformer and remove from customer site, install secondary terminating cabinet over the existing and new secondary cables at old transformer location. Provide concrete for pad extension as necessary for secondary terminating cabinet, make secondary terminations in terminating cabinet, and provide and install 4 - 6” bollards at new transformer location.
NAICS code 238210. Vendors who are interested shall submit a concise capability statement, outlining their ability to fulfill this requirement, to Kimberly Devlin at kimberly.devlin@va.gov and Joseph Osborn at joseph.osborn@va.gov by 1:00pm EST June 14, 2024. The statement should not exceed 5 pages. Please provide the necessary information, including your size status, Point of Contact (POC) details, email address, phone number, Cage Code, UEI, and any schedules you may be on, with your reply.
Site Visit Dates June 10th – June 14th from 0900 – 11am Please specify the date you are available for a site visit in your reply.
This is not a formal Request for Proposal or solicitation announcement. The Government is not required to acknowledge receipt of information or provide feedback to respondents regarding the submitted information. Telephone inquiries or requests will not be entertained. The Government will utilize the information received for market research purposes ONLY.
Attachment 1: Statement of Work Attachment 2: GA Power Service Manual
| *= Required Field |
| Sources Sought Notice |
Page 1 of
Sources Sought Notice
File details come from the government source that posted it. Updated .