36C24626Q0654 LineItems -N.xlsx

XLSX spreadsheet 451 KB Posted

Attached to
H246--Critical Water Testing Federal contract opportunity
Solicitation number
36C24626Q0654
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This is a line items spreadsheet for a Request for Quote (RFQ) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 (VISN 6) for critical water testing services at Fredericksburg Healthcare Coordination Center (HCC). The solicitation number is 36C24626Q0654, and the action type is VHA-SERVICES-RFQ with a percent-based order discount structure.

The procurement encompasses comprehensive water management and testing services for sterile processing systems over a one-year period. Line items include an initial two-month water management plan development (Item 0001), nine months of monthly facilitation services (Item 0002), and extensive water chemistry and microbiology testing across multiple phases. The new system start-up phase (Items 0003-0011) requires 15 critical water chemistry panels, 9 utility water chemistry panels, 18 additional critical water panels, 12 utility panels for final rinse/high-level disinfection, 18 utility panels for first point-of-use testing, 20 heterotrophic plate count retests, 20 LAL/endotoxin retests, 12 standard shipping units, and 2 expedited shipping units. The ongoing monitoring phase (Items 0012-0020) specifies 22 critical water chemistry panels over 11 months, 77 critical water samples for HPC and endotoxin analysis, 66 utility water panels for final rinse procedures over 11 months, 4 quarterly utility water chemistry panels, 8 quarterly utility water panels for first point-of-use, 24 quarterly heterotrophic plate count samples, 8 quarterly steam water chemistry panels, and 24 each of HPC and LAL/endotoxin retests. All items are priced on a quantity basis with unit of measure in each (EA) or job (JB) categories, with quantities requested as expendable items.

View the file

Other files for this federal contract opportunity

Other files attached to H246--Critical Water Testing, newest first.
File Type Posted
36C24626Q0654.docx DOCX document
36C24626Q0654 - Critical Water Testing.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Action Line Item Information

Action Type NamePrimary IDSecondary IDMod NumberTitleOrder Discount Type NameOrder Discount TypeOrder Discount
VHA-SERVICES-RFQ36C24626Q0654Critical Water Testing
Fredericksburg HCCPercent0

KB Version: FY26.07B

Items

ITEM NUMBERSLINDESCRIPTIONREF CLINCOMMENTINCLUDE COMMENTS IN DOCUMENTCONTRACT PERIODPOP BEGINPOP ENDQUANTITYUNIT OF MEASUREPACKAGING MULTIPLERECEIPT TYPELINE ITEM ISUNIT PRICEITEM DISCOUNT TYPE NAMEITEM DISCOUNTDATE UPDATEDADDRESS1ADDRESS2ADDRESS3CITYSTATEZIPZIP4COUNTRYMARK FROCONTACT NAMECONTACT PHONECONTACT EMAILDELIVERY DATEFOBSPECIAL INSTRUCTIONSINCLUDE INSTRUCTIONS/COMMENTS IN DOCUMENTINCLUDE DATA VALUES IN DOCUMENTPRINCIPAL NAICS CODEPRODUCT/SERVICE CODEUNSPSCSIC CODEMANUFACTURER PART NUMBER (MPN)NATIONAL STOCK NUMBERLOCAL STOCK NUMBERDM DOC IDDELIVERY REF. COUNTERUNIT TEXT/DESCRIPTIONDELIVERY REFERENCEITEM MASTER FILE NUMBEREXPENDABLE/NON-EXPENDABLEQUANTITY REQUESTEDUNIT OF PURCHASE CODE
0001Water Management Plan - Sterile Processing WMS-5600 (2 months Development)Water Management Plan - Sterile Processing WMS-5600 (2 months Development)No1JB0QuantityPricedPercent0NONENoNon/a00E1JB
0002Water Management Plan - Sterile Processing WMS-5600 Facilitation WMS-5650 (Monthly)Water Management Plan - Sterile Processing WMS-5600 Facilitation WMS-5650 (Monthly)No9JB0QuantityPricedPercent0NONENoNon/a00E9JB
0003WC-5200 ST108 Critical Water Chemistry Panel with Microbio - Qualification (New System Start-up Day 1) (Tables 2 of ST108)WC-5200 ST108 Critical Water Chemistry Panel with Microbio - Qualification (New System Start-up Day 1) (Tables 2 of ST108)No15EA0QuantityPricedPercent0NONENoNon/a00E15EA
0004WC-5100 ST108 Utility Water Chemistry Panel with Microbio - Qualification (New System Start-up Day 1) (Tables 2 of ST108)WC-5100 ST108 Utility Water Chemistry Panel with Microbio - Qualification (New System Start-up Day 1) (Tables 2 of ST108)No9EA0QuantityPricedPercent0NONENoNon/a00E9EA
0005WC-5220 ST108 Critical Water Chemistry Panel with Microbio - Generation and First POU (New System Start -up Day 2 and 3)WC-5220 ST108 Critical Water Chemistry Panel with Microbio - Generation and First POU (New System Start -up Day 2 and 3)No18EA0QuantityPricedPercent0NONENoNon/a00E18EA
0006WC-5140 ST108 Utility Water Chemistry Panel with Microbio - Final Rinse/High Level Disinfection (New System Start up, 6 samples a day for day 2 and 3)WC-5140 ST108 Utility Water Chemistry Panel with Microbio - Final Rinse/High Level Disinfection (New System Start up, 6 samples a day for day 2 and 3)No12EA0QuantityPricedPercent0NONENoNon/a00E12EA
0007WC-5130 ST108 Utility Water Chemistry Panel with Microbio - First POU (New System Start-up, 9 samples per day for day 2 and 3)WC-5130 ST108 Utility Water Chemistry Panel with Microbio - First POU (New System Start-up, 9 samples per day for day 2 and 3)No18EA0QuantityPricedPercent0NONENoNon/a00E18EA
0008MB-2530 Heterotrophic Plate Count - MDR (Retest for New system start up)MB-2530 Heterotrophic Plate Count - MDR (Retest for New system start up)No20EA0QuantityPricedPercent0NONENoNon/a00E20EA
0009MB-3130 LAL/Endotoxin - MDR (Retest for New System Start up))MB-3130 LAL/Endotoxin - MDR (Retest for New System Start up))No20EA0QuantityPricedPercent0NONENoNon/a00E20EA
0010WMS-9970 Shipping and Handling (New System start up 4 boxes per day)WMS-9970 Shipping and Handling (New System start up 4 boxes per day)No12EA0QuantityPricedPercent0NONENoNon/a00E12EA
0011WMS-9972 Shipping and Handling Expedited (New system start up retest)WMS-9972 Shipping and Handling Expedited (New system start up retest)No2EA0QuantityPricedPercent0NONENoNon/a00E2EA
0012WC-5220 ST108 Critical Water Chemistry Panel with Microbio - Generation and First POU (2 samples per month for 11 months)WC-5220 ST108 Critical Water Chemistry Panel with Microbio - Generation and First POU (2 samples per month for 11 months)No22EA0QuantityPricedPercent0NONENoNon/a00E22EA
0013MB-3330 ST108 Critical Water - HPC & Endotoxin (7 samples per month for 11 months)MB-3330 ST108 Critical Water - HPC & Endotoxin (7 samples per month for 11 months)No77EA0QuantityPricedPercent0NONENoNon/a00E77EA
0014WC-5140 ST108 Utility Water Chemistry Panel with Microbio - Final Rinse/High Level Disinfection (6 samples per month for 11 months)WC-5140 ST108 Utility Water Chemistry Panel with Microbio - Final Rinse/High Level Disinfection (6 samples per month for 11 months)No66EA0QuantityPricedPercent0NONENoNon/a00E66EA
0015WC-5120 ST108 Utility Water Chemistry Panel - Generation (1 sample per quarter for 4 quarters)WC-5120 ST108 Utility Water Chemistry Panel - Generation (1 sample per quarter for 4 quarters)No4EA0QuantityPricedPercent0NONENoNon/a00E4EA
0016WC-5130 ST108 Utility Water Chemistry Panel with Microbio - First POU (2 samples per quarter for 4 quarters)WC-5130 ST108 Utility Water Chemistry Panel with Microbio - First POU (2 samples per quarter for 4 quarters)No8EA0QuantityPricedPercent0NONENoNon/a00E8EA
0017MB-2570 ST108 Utility Water - Heterotrophic Plate Count (HPC) (6 samples per quarter for 4 quarters)MB-2570 ST108 Utility Water - Heterotrophic Plate Count (HPC) (6 samples per quarter for 4 quarters)No24EA0QuantityPricedPercent0NONENoNon/a00E24EA
0018WC-5300 ST108 Steam Water Chemistry panel - Steam Condensate (2 quarterly samples for 4 quarters)WC-5300 ST108 Steam Water Chemistry panel - Steam Condensate (2 quarterly samples for 4 quarters)No8EA0QuantityPricedPercent0NONENoNon/a00E8EA
0019MB-2530 Heterotrophic Plate Count - MDR (Retest)MB-2530 Heterotrophic Plate Count - MDR (Retest)No24EA0QuantityPricedPercent0NONENoNon/a00E24EA
0020MB-3130 LAL/Endotoxin - MDR (Retest)MB-3130 LAL/Endotoxin - MDR (Retest)No24EA0QuantityPricedPercent0NONENoNon/a00E24EA