S05 658-24-104 Mob Area sheets A101. A111. A112.pdf
PDF 5 MB Posted
- Attached to
- Z1DA--Renovate Main Lobby Federal contract opportunity
- Solicitation number
- 36C24626B0027
About this file
Summary of Construction Documents - V.A. Medical Center, Salem, VA
This document is a set of architectural construction drawings and specifications for renovation work at the V.A. Medical Center in Salem, VA, specifically the Basement Lobby and Corridor areas. The project includes comprehensive updates to finishes, partitions, ceilings, and building systems. Key construction work involves new terrazzo and ceramic tile flooring, wall painting and vinyl protection, new gypsum board partitions, acoustic ceiling tile installation and grid work, expansion joint sealants, plumbing fixtures including a single water fountain with bottle filler, and coordination with existing DIRTT wall systems. New ceiling-hung toilet partitions, corner guards, handrails, and wall tile installations are also specified. The contractor is responsible for protecting existing construction from damage, coordinating equipment and furniture salvage with the VA upon renovation completion, and verifying all existing dimensions and clearances before proceeding.
The drawings establish specific construction notes and legends for existing versus new construction elements, fire barriers, smoke barriers, and mechanical systems. Notable requirements include code-compliant wood blocking or sheet metal plates for all wall-mounted accessories, matching partition types to existing adjoining walls for flush transitions, and comprehensive coordination with mechanical, electrical, and plumbing systems. The contractor must immediately notify the architect of any discrepancies between existing conditions and contract documents. A detailed phasing sequence is referenced for overall project coordination. The work is divided into basement areas including the lobby and multiple corridors (CB-45, CG-16, CG-28), with construction occurring in phases to maintain facility operations and coordinate with VA stakeholders.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FAR 52.222-90.pdf | ||
| S06 36C24626B0027 0002.pdf | ||
| S05 ICRA Requirements _ Renovate Main Lobby.pdf | ||
| S05 658-24-104 Questions and Answer_ Renovate Main Lobby.pdf | ||
| S06 36C24626B0027 0001.pdf | ||
| S04 Site Visit 4-17-2026_ Main Lobby.pdf | ||
| S02 36C24626B0027 Renovate Main Lobby.pdf | ||
| S02 Salem Lobby Renovation - Bid Documents - Specifications.pdf | ||
| S02 Salem Lobby Renovation - Bid Documents - Drawings.pdf | ||
| VAAR 852.204-70_PIV of Contractor Personnel.pdf | ||
| 36C24626B0027.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHASAMSwitzW Image
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
DIMENSIONS TO FACE OF STUD UNLESS NOTED OTHERWISE.
ALL PARTITIONS ARE TYPE 2B UNLESS NOTED OTHERWISE.
SEE ENLARGED PLANS OF TOILETS FOR PARTITION TYPES IN THE AREAS
REFERENCED.
DOORS REFERENCED BY A DOOR NUMBER INDICATE A NEW DOOR OR
SOME MODIFICATION TO AN EXISTING DOOR. SEE DOOR SCHEDULE.
DOORS WITHOUT DOOR NUMBER REFERENCES ARE EXISTING DOORS TO
REMAIN, WITH NO WORK OR MODIFICATION REQUIRED.
PROVIDE CODE COMPLIANT WOOD BLOCKING OR SHEET METAL PLATES IN
HOLLOW WALL SYSTEMS FOR ATTACHMENT OF ANY WALL MOUNTED
ACCESSORIES INCLUDING, BUT NOT LIMITED TO, SHELVING, CASEWORK,
TOILET ACCESSORIES, TOILET PARTITIONS, LIGHT FIXTURES, BENCHES,
COAT RODS, AUDIO VISUAL EQUIPMENT, MARKER BOARDS, MIRRORS, ETC.
WALL ACCESSORIES SUCH AS FIRE EXTINGUISHER CABINETS AND PAPER
TOWEL DISPENSERS THAT REQUIRE A SEMI-RECESSED INSTALLATION
SHALL NOT REDUCE THE FIRE RATING OF THE WALL. IF A DETAIL IS NOT
PROVIDED WITHIN THE CONTRACT DOCUMENTS, THE CONTRACTOR
SHALL CONSULT THE ARCHITECT FOR PROPER DETAILS PRIOR TO
INSTALLING THE ACCESSORY.
PARTITION TYPES AT INFILL WALLS SHALL MATCH ADJOINING EXISTING
WALLS PROVIDING FOR A FLUSH, SMOOTH TRANSITION IN THE FINISHED
SURFACE. MATCH BASE IN AREAS WHERE BASE IS OTHERWISE
INDICATED TO REMAIN, RUNNING FROM AN INTERIOR CORNER OR OTHER
DEFINED EDGE.
PATCH AND REPAIR ALL GYPSUM BOARD SURFACES WHERE DEMOLITION
OF ADJOINING OR INTERSECTING PARTITIONS HAS RESULTED IN LESS
THAN A FINISHED CONDITION. PATCHES SHALL BE FLUSH AND SMOOTH.
EXISTING ROOMS THAT ARE NOT INDICATED TO BE AFFECTED BY THE
WORK ARE TO BE PROTECTED FROM DAMAGE AND/OR PAINT
DEGRADATION. SHOULD THE GENERAL CONTRACTOR AFFECT THE
CONDITION OR FINISH OF THESE ROOMS, THE SURFACE OR SPACE SHALL
BE RESTORED TO ORIGINAL CONDITION.
REFERENCE DEMOLITION DRAWINGS FOR GENERAL DEMOLITION PLANS.
WHERE NEW CONSTRUCTION ABUTS EXISTING CONSTRUCTION IN THE
SAME PLANE, FINISHES SHALL BE FLUSH. VERIFY ALL DIMENSIONS TO
EXISTING ELEMENTS.
NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES BETWEEN
EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE
PROCEEDING WITH THAT PORTION OF THE WORK. FAILURE TO NOTIFY
THE ARCHITECT WILL NOT RELIEVE THE CONTRACTOR OF THE
RESPONSIBILITY TO PERFORM THE WORK AS INTENDED BY THE
CONTRACT DOCUMENTS.
VERIFY EXISTING DIMENSIONS, CONDITIONS AND CLEARANCES PRIOR TO
THE SUBMISSION OF SHOP DRAWINGS.
GC IS REPONSIBLE FOR COORDINATING WITH VA WHAT EXISTING
EQUIPMENT AND FURNITURE TO BE TAGGED SALVAGED AND RETURNED
ONCE AN AREA HAS COMPLETED RENOVATION.
PHASING SEQUENCE - REFER TO G004 FOR OVERALL PHASING FOR
DETAILS AND COORDINATION FOR SCOPE.
GENERAL FLOOR PLAN NOTES:
8.6
SRQP
6.2
A131
ONML R.8R.5
9.3
8.2
7.5
6.8
T U
V
W
X
A301
A301
A301
A131
A131
MATCH LINE 01 MATCH LINE 01
/2 A102
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
A1
/1 A102 /1 A102
MATCH LINE 03 MATCH LINE 03
A131
WAITING
CB-10
WAITING
CB-9
WAITING
CB-8
WAITING
CB-7
RECEPTION
CB-8A
VIRTUAL HEALTH
CB-14
WAITING
CB-13
RECEPTION
CB-13A
WAITING
CB-12
FAMILY TOILET
BB-153
MEN'S TOILET
BB-121
WOMEN'S TOILET
BB-101
CORRIDOR
CB-15
INFO
CB-4
LOBBY
CB-5
CAFE
BA-102
MEN'S TOILET
BA-101 WOMEN'S TOILET
BA-100
ENTRANCE
CB-2
VESTIBULE
CB-1
LOBBY
CB-11
CONCOURSE
CB-15
CORRIDOR
CB-45
3 3
FE
C
555555555
5 5 5 5
5 5
5 5
33 3 3 3
3 3
8 8
9 9
10 10
10 8
6" 5'
- 0
9'- 8"
4"
A501
A501
A501
/2 A102
A1
14 14 14
4 4
4 4
4 4
10 10
108 9
10 10 8
CG
CGCGCGCGCGCGCG
CGCGCGCGCGCGCGCG
CG
CG
CG
CG
3 3
CGCG
CG CG CG CG
CG
CG CG
CG
CGCG
CG
CG
CONSULT
BF-103
CONSULT
BF-102
CONSULT
BF-101
CGCG
EXISTING
DIRTT WALL
/2 A10
MATCH LIN
E
BA-102D
1 1 1
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION LEGEND:
NEW DOOR LEAF
NEW PARTITON
4 NEW CONSTRUCTION NOTE
EXISTING 2 HR FIRE RATED FIRE BARRIER
EXISTING SMOKE BARRIER
DEDUCT ALTERNATE AREA.
REFER TO G001 FOR DETAILS.
CORNER GUARDS
CG
HANDRAIL
NOT IN SCOPE
OF WORK
KEY PLAN
PROJECT AREA
N
PROJECT
NORTH
TRUE
NORTH
VESTIBULE
CB-1
EXTENT OF PRESSURE
WASHING EXTERIOR ENTRY
/1 A10
MATCH LI
NE
1/8" = 1'-0"
BASEMENT PLAN - LOBBY
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RD JC
Drawing File Number
Au to de sk
D oc s:
//2
V A
Sa le m L ob by
/2
V
A Sa le m
L ob by .rv t 4/
/2
3:
:2
PM
BASEMENT PLAN - LOBBY BUILDING 143 LOBBY
RENOVATION
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD, SALEM, VA 24153-6406
09 JANUARY 2026
100% CONSTRUCTION
DOCUMENTS
A101
658-24-104
SHEET 15 OF 59
CONSTRUCTION NOTES
(APPLY TO THIS SHEET ONLY)
1 NEW TERAZZO FLOOR FINISH. SEE FINISH PLAN A601 FOR PATTERN.
2 NEW CERAMIC TILE FLOOR. SEE FINISH PLAN A601 FOR PATTERN.
3 NEW WALL PAINT. SEE FINISH SCHEDULE.
4 NEW VINYL WALL PROTECTION 4' HEIGHT. SEE FINISH SCHEDULE. DEDUCT
ALTERNATE 2A, 2B
5 NEW VINYL COLUMN COVER. SEE 9/A501.
7 CONTRACTOR TO COORDINATE WITH BANK AND VA TO REMOVE AND
REPLACE ATM MACHINE.
8 NEW PLUMBING FIXTURE. SEE PLUMBING DRAWINGS.
9 NEW CEILING HUNG TOILET PARTITION. SEE DETAIL 2/A111.
10 NEW WALL TILE. SEE PARTITION 1A/ G008 & SECTION DETAILS SHEET.
11 NEW EXPANSION JOINT SEALANT AND COVER TO BE FLUSH WITH
ADJACENT SURFACE. SEE DETAILS ON A502.
12 NEW HANDRAIL. SEE DETAILS A501.
14 NEW WALL PROTECTION UP TO 4'-0". SEE 9/A501.
16 PROTECT EXISTING WALL FINISH FROM DAMAGE
17 INFILL FLOOR SLAB. SEE STRUCTURAL .
18 NEW PARTITION SEE 2A/ 2B ON G008
19 NEW SINGLE WATER FOUNTAIN WITH BOTTLE FILLER. SEE PLUMBING
SCHEDULE.
20 REMOVE EXISTING DIRTT WALL SYSTEM AND REINSTALL PANELS AFTER
INSTALLATION OF TERRAZZO FLOORING WITHIN THE DURATION OF PHASE
2D. COORDINATE WITH MEP FOR DEMOLITION AND REINSTALLATION.
COORDINATE WITH DIRTT WALL MANUFACTURE FOR DIRTT-PANEL
REMOVAL INSTRUCTIONS AS NECESSARY. REINSTALLATION TO BE IN THE
SAME LOCATION.
1/8" = 1'-0"
ENTRY PRESSURE WASHING PLAN
Revision Number
Date: Revisions:
1 5/1/2026 PreBid
C.
D.
E.
F.
IN ANY UNBRACED AREA OF CEILING WHICH IS LESS THAN 1000 SF, IT IS
REQUIRED THAT SPRINKLER HEADS AND OTHER PENETRATIONS BE
INSTALLED WITH A 2" OVERSIZED RING, SLEEVE, OR ADAPTER THROUGH
THE CEILING TILE TO ALLOW FOR ONE INCH OF FREE MOVEMENT IN ALL
HORIZONTAL DIRECTIONS.
HEIGHT OF CEILING ABOVE FINISH FLOOR IS TAKEN FROM FLOOR
SURFACE DIRECTLY BELOW.
SUSPENSION GRIDS SHALL BE CENTERED IN ALL SPACES UNLESS
INDICATED OTHERWISE ON ARCHITECTURAL RCP.
ALL DEVICES MOUNTED IN ACOUSTICAL CEILING TILES SUCH AS LIGHTS,
SPEAKERS, EXHAUST GRILLES, SPRINKLER HEADS, SMOKE DETECTORS,
REMOTE TEST SWITCHES FOR DUCT DETECTORS, ETC. SHALL BE
CENTERED IN THE ACOUSTICAL CEILING TILE U.N.O. ALL DEVICES SHALL
BE INDEPENDENTLY SUPPORTED.
SPRINKLER HEADS IN GYPSUM BOARD CEILINGS SHALL BE CENTERED
AND ALIGN WITH RECESSED LIGHT FIXTURES IF APPLICABLE.
PROVIDE CEILING ACCESS PANELS IN GWB CEILINGS TO PROVIDE ACCESS
TO ELECTRICAL, MECHANICAL AND PLUMBING DEVICES THAT REQUIRE
SERVICE FOR MAINTENANCE. CONFER WITH A/E PRIOR TO PLACEMENT.
GENERAL RCP NOTES:
EXISTING 1' X 4' LIGHT FIXTURE
EXISTING 6" RECESSED CAN LIGHT
NEW 12" PENDANT LIGHT
EXISTING 12" EXHAUST GRILLE, SEE
MECHANICAL DRAWINGS
1 HOUR RATED FIRE BARRIER
2 HOUR RATED FIRE BARRIER
RATED SMOKE BARRIER
RCP LEGEND:
EXISTING ACT 2' x 2' - ACOUSTIC CEILING TILE
EXISTING ACT 2' x 4' - ACOUSTIC CEILING TILE
EXISTING GYP BOARD CEILING
EXISTING EXIT SIGN
EXISTING RECESSED CAN
FLUORESCENT LIGHT FIXTURE
EXISTING SPRINKLER HEAD
EXISTING 2 X 4 FIXTURE
EXISTING SUPPLY 2X2 DIFFUSER GRILL
EXISTING RETURN GRILL
EXISTING SPEAKER
EXISTING SMOKE DETECTOR
EXISTING MECHANICAL DIFFUSER
EXISTING 2 X 2 FIXTURE
EXISTING EXPANSION JOINT COVER
SD
NEW ACT 2' x 2' - ACOUSTIC CEILING TILE
NEW MECHANICAL DIFFUSER
NEW RECESSED CAN FLUORESCENT
LIGHT FIXTURE
EXISTING 2 X 4 FIXTURE
NEW 2 X 2 FIXTURE
NEW SUPPLY 2X2 DIFFUSER GRILL
A301
A301
A301
/1 A102 /1 A102
MATCH LINE 03 MATCH LINE 03
/2 AD102
MATCH LINE 01 MATCH LINE 01
/2 AD102
AD
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
AD
SD
SD
SD
21 21
21 21
9'-8"
9'-8" 9'-8"
9'-8"
WOMEN'S TOILET
BA-100
WOMEN'S TOILET
BB-101
MEN'S TOILET
BA-101
MEN'S TOILET
BB-121
FAMILY TOILET
BB-153
CONSULT
BF-103
CONSULT
BF-102
CONSULT
BF-101
WAITING
CB-10 WAITING
CB-9
LOBBY
CB-11
WAITING
CB-12
WAITING
CB-13
WAITING
CB-8
WAITING
CB-7
VIRTUAL HEALTH
CB-14
CONCOURSE
CB-15
INFO
CB-4
ENTRANCE
CB-2
VESTIBULE
CB-1
RECEPTION
CB-8A
RECEPTION
CB-13A
CORRIDOR
CB-15
CAFE
BA-102
LOBBY
CB-5
CORRIDOR
CB-45
8'-6"
8'-6"
9'-0"
8'-6"
8'-6"
8'-8" 8'-8"
8'-8"
232323
2323 3 G008
G008
SIM.
25 25
26 26 26
25 25
25 25
25 25
25 25
A111
A111
A111
A111
A111
A111
A111
A111
8'-8"
TYP.
EX. CEILING
ACCESS PANEL
9'-0"
8'-0"
8'-0"
9'-0"1 A502
A502
A502
15151515 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15
27 TYP.27 TYP.27 TYP.27 TYP.27 TYP.27 TYP.
27 TYP. 27 TYP.
27 TYP.
36' - 7"
3B G008
9'-0"
9'-0"
3B G008
KEY PLAN
PROJECT AREA
N
PROJECT
NORTH
TRUE
NORTH
12 GA PERIMETER HANGER
WIRE AT ALL TEES. INSTALL.
EITHER SLOPED TO WALL
(1:6 MAX) OR VERICALLY
STRUCTURE
2" PERIMETER CLOSURE
MOLDING. ATTACHED TO WALL
AND CONNECTED TO GRID
INTERIOR PARTITION WALL
BRACED OR EXTENDED TO
UNDERSIDE OF STRUCTURE
WALL MOLDING - SEE
SPECIFICATIONS FOR TYPE.
8" MAX.
U.S. OF DECK
1/2" DIA. THREADED ROD
WITH HEAVY HEX NUTS AT
EACH PARTITION
CONNECTION (3 MINIMUM)
STEEL CHANNEL.
SEE STRUCTURAL.
TOP OF TOILET PARTITION.
SEE MANUFACTURER'S DETAIL
METAL CLIP
3/8" STUD BOLT
TOILET PARTITION. SEE FINISH
SCHEDULE.
SUSPENDED CEILING TILE
LATERALLY BRACED STEEL
CHANNEL. SEE STRUCTURAL
2 1/2" x 2 1/2" x 1/4" ANGLE
SPACED AT 3'-0" O.C.
SEE STRUCTURAL.
2 1/2" x 2 1/2" x 1/4"
CONTINUOUS ANGLE. SEE
STRUCTURAL.
0.157" DIA. PAF SPACED
AT 16" O.C.
NOTE: SEE STRUCTURAL DETAILS.
EXISITING GYP
BD CEILING SEE A111 FOR
ELEVATION HEIGHT
LOWER THE WALL MOLD BY THE
HEIGHT OF TEGULAR REVEAL
SPACE BLOCK BY TEG TEB AT
ALL PERIMETER TILES
TEGULAR CEILING TILE
( PERMIETER TILE TO BE CUT TO SQUARE )
ACUSTICAL GRID
HANGER TO STRUCTURE 21
CAFE
BA-102
LOBBY
CB-5
G008
G008
SIM.
9'-0"
8'-0"
8'-0"
9'-0"
27 TYP. 27 TYP.
27 TYP.
12'-0 3/8"
12'-0 3/8"
EXISTING WALL
TO REMAIN ABOVE
CEILING
EXISTING
WALL
TO REMAIN
ABOVE
CEILING
3B G008
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RD JC
Drawing File Number
Au to de sk
D oc s:
//2
V A
Sa le m L ob by
/2
V
A Sa le m
L ob by .rv t 4/
/2
3:
:2
PM
BASEMENT RCP - LOBBY BUILDING 143 LOBBY
RENOVATION
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD, SALEM, VA 24153-6406
09 JANUARY 2026
100% CONSTRUCTION
DOCUMENTS
A111
658-24-104
SHEET 17 OF 59
1/8" = 1'-0"
BASEMENT RCP - LOBBY
CONSTRUCTION NOTES
(APPLY TO THIS SHEET ONLY)
9 NEW CEILING HUNG TOILET PARTITION. SEE DETAIL 2/A111.
11 NEW EXPANSION JOINT SEALANT AND COVE R TO BE FLUSH
WITH ADJACENT SURFACE. SEE DETAILS ON A502.
15 NEW PENDANT LIGHT. B.O.D. SEQUENCE PENDANT LIGHT
CP2024 4" x 48"
21 NEW ACOUSTICAL CEILING GRID AND CEILING TILES.
23 NEW CEILING AND WALL EXTENSION. SEE DETAIL 2/G008.
24 NEW ACOUSTICAL WALL PANELS. SEE DETAIL 2/G008.
25 NEW MECHANICAL GRILLS. SEE MECHANICAL DRAWINGS
26 EXISTING LIGHT TO BE MOVED TO CENTER OF CORRIDOR PER
REVISED CEILING GRID LAYOUT.
27 GC TO INSPECT AND RESEAL ALL EXISTING WINDOWS AND
SKYLIGHTS IN ATRIUM. CONTRACTOR RESPONSIBLE TO
REMOVE ANY CAULKING AND PREP SURFACE FOR NEW
CAULKING RE APPLICATION TO BE SEALED WITH
WEATHER-RESISTANT TO FULLL ANY GAPS FOR WATERTIGHT
CONDITIONS.
28 LRP PANELS TO REMAIN. CONTRACTOR TO COORDINATE NEW
ACT AND EXISTING LRP PANELS. 3" = 1'-0"
ACOUSTICAL CEILING END ANGLE
MOLDING DETAIL 1 1/2" = 1'-0"
TYP. CEILING HUNG TOILET PARTITION
DETAIL
1/8" = 1'-0"
BASEMENT RCP - LOBBY
Revision Number
Date: Revisions:
1 5/1/2026 PreBid
C.
D.
E.
F.
IN ANY UNBRACED AREA OF CEILING WHICH IS LESS THAN 1000 SF, IT IS
REQUIRED THAT SPRINKLER HEADS AND OTHER PENETRATIONS BE
INSTALLED WITH A 2" OVERSIZED RING, SLEEVE, OR ADAPTER THROUGH
THE CEILING TILE TO ALLOW FOR ONE INCH OF FREE MOVEMENT IN ALL
HORIZONTAL DIRECTIONS.
HEIGHT OF CEILING ABOVE FINISH FLOOR IS TAKEN FROM FLOOR
SURFACE DIRECTLY BELOW.
SUSPENSION GRIDS SHALL BE CENTERED IN ALL SPACES UNLESS
INDICATED OTHERWISE ON ARCHITECTURAL RCP.
ALL DEVICES MOUNTED IN ACOUSTICAL CEILING TILES SUCH AS LIGHTS,
SPEAKERS, EXHAUST GRILLES, SPRINKLER HEADS, SMOKE DETECTORS,
REMOTE TEST SWITCHES FOR DUCT DETECTORS, ETC. SHALL BE
CENTERED IN THE ACOUSTICAL CEILING TILE U.N.O. ALL DEVICES SHALL
BE INDEPENDENTLY SUPPORTED.
SPRINKLER HEADS IN GYPSUM BOARD CEILINGS SHALL BE CENTERED
AND ALIGN WITH RECESSED LIGHT FIXTURES IF APPLICABLE.
PROVIDE CEILING ACCESS PANELS IN GWB CEILINGS TO PROVIDE ACCESS
TO ELECTRICAL, MECHANICAL AND PLUMBING DEVICES THAT REQUIRE
SERVICE FOR MAINTENANCE. CONFER WITH A/E PRIOR TO PLACEMENT.
GENERAL RCP NOTES:
EXISTING 1' X 4' LIGHT FIXTURE
EXISTING 6" RECESSED CAN LIGHT
NEW 12" PENDANT LIGHT
EXISTING 12" EXHAUST GRILLE, SEE
MECHANICAL DRAWINGS
1 HOUR RATED FIRE BARRIER
2 HOUR RATED FIRE BARRIER
RATED SMOKE BARRIER
RCP LEGEND:
EXISTING ACT 2' x 2' - ACOUSTIC CEILING TILE
EXISTING ACT 2' x 4' - ACOUSTIC CEILING TILE
EXISTING GYP BOARD CEILING
EXISTING EXIT SIGN
EXISTING RECESSED CAN
FLUORESCENT LIGHT FIXTURE
EXISTING SPRINKLER HEAD
EXISTING 2 X 4 FIXTURE
EXISTING SUPPLY 2X2 DIFFUSER GRILL
EXISTING RETURN GRILL
EXISTING SPEAKER
EXISTING SMOKE DETECTOR
EXISTING MECHANICAL DIFFUSER
EXISTING 2 X 2 FIXTURE
EXISTING EXPANSION JOINT COVER
SD
NEW ACT 2' x 2' - ACOUSTIC CEILING TILE
NEW MECHANICAL DIFFUSER
NEW RECESSED CAN FLUORESCENT
LIGHT FIXTURE
EXISTING 2 X 4 FIXTURE
NEW 2 X 2 FIXTURE
NEW SUPPLY 2X2 DIFFUSER GRILL
KEY PLAN
PROJECT AREA
N
PROJECT
NORTH
TRUE
NORTH
/1 A101 /1 A101
MATCH LINE 03 MATCH LINE 03
WOMEN'S TOILET
BB-101
CORRIDOR
CB-15
8'-6"
8'-8"
A502
/1 A101 /1 A101
MATCH LINE 01 MATCH LINE 018
CORRIDOR
CB-45
8'-0"
A502
A502
A502
A502
A502
A502
A1
A1
M
AT
C H
L
IN
E
M
AT
C H
L
IN
E
8CORRIDOR
CG-25
9'-0" 16 17 17 17 1716 16 16 16
1/8" = 1'-0"
BASEMENT RCP CORRIDOR CB-15
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RD JC
Drawing File Number
Au to de sk
D oc s:
//2
V A
Sa le m L ob by
/2
V
A Sa le m
L ob by .rv t 4/
/2
3:
:2
PM
BASEMENT RCP - CORRIDORS BUILDING 143 LOBBY
RENOVATION
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD, SALEM, VA 24153-6406
09 JANUARY 2026
100% CONSTRUCTION
DOCUMENTS
A112
658-24-104
SHEET 18 OF 59
1/8" = 1'-0"
BASEMENT RCP CORRIDOR CB-45
1/8" = 1'-0"
BASEMENT RCP CORRIDOR CG-25
CONSTRUCTION NOTES
(APPLY TO THIS SHEET ONLY)
8 NEW ACOUSTICAL CEILING.
9 NEW CEILING HUNG TOILET PARTITION. SEE DETAIL 2/A111.
11 NEW EXPANSION JOINT SEALANT AND COVER.
16 NEW MECHANICAL GRILLS. SEE MECHANICAL DRAWINGS
17 EXISTING LIGHT TO BE MOVED TO CENTER OF CORRIDOR.
28 LRP PANELS TO REMAIN. CONTRACTOR TO COORDINATE NEW
ACT AND EXISTING LRP PANELS.
Revision Number
Date: Revisions:
1 5/1/2026 PreBid
| A101 - BASEMENT PLAN - LOBBY |
| A111 - BASEMENT RCP - LOBBY |
| A112 - BASEMENT RCP - CORRIDORS |
File details come from the government source that posted it. Updated .