About this file

This is a set of construction drawings and specifications for updating the public address system at the Veterans Affairs Medical Center in Salisbury, North Carolina. The project involves installing new public address source equipment and cabling to provide zoned voice paging across 23 buildings on the campus. New equipment will be connected to the existing data network and will interface with nurse call and fire alarm systems. Fiber optic cabling will be run through conduits, tunnels, and manholes to link buildings to the main PA equipment location. Speakers in each building will be reconnected to the new system. The drawings provide floor plans depicting conduit routing and speaker locations. Specifications include equipment requirements and coordination notes. The opportunity is open to all contractors and has an estimated value over $2,000.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--Update PA System, newest first.
File Type Posted
36C24624B0001 0005.docx DOCX document
Bid Opening Attendance 12-13-23.pdf PDF
Bid Abstract - 36C24624B0001.pdf PDF
36C24624B0001 0004.docx DOCX document
36C24624B0001 0003.docx DOCX document
36C24624B0001 0002.docx DOCX document
36C24624B0001 0001.docx DOCX document
S02 - Revised 659-22-201 Drawings 10-27-23.pdf PDF
S02 - Revised 659-22-201 Specifications 10-27-23.pdf PDF
36C24624B0001_1.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED

Department of Veterans Affairs Medical Center

ABOVE GROUP, INC.

MECHANICAL ELECTRICAL PLUMBING

305 EAST DRIVE, SUITE H

MELBOURNE, FL 32904

321.345.9026 P

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

JOHN POE ARCHITECTS, LLC

ARCHITECT

3131 NEWMARK DRIVE, SUITE 200

DAYTON, OHIO 45342

937.461.3290 P

W.G. (Bill) Hefner

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:2

A

M

G-001

COVER SHEET VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

VAMC Salisbury - Upgrade PA System

1601 Brenner Ave, Salisbury, NC 28144 PROJECT #: 659-22-201

SHEET LIST

SHEET NUMBER SHEET NAME

GENERAL

G-001 COVER SHEET

ELECTRICAL

E-001 ELECTRICAL LEGENDS & SYMBOLS

ED100 ELECTRICAL SITE PLAN - DEMO

EY100 ELECTRICAL SITE PLAN

EY101 B1 - BASEMENT PLAN - PA SYSTEM

EY102 B1 - FIRST FLOOR PLAN - PA SYSTEM

EY103 B1 - SECOND FLOOR PLAN - PA SYSTEM

EY104 B2 - BASEMENT PLAN - PA SYSTEM

EY105 B2 - FIRST FLOOR PLAN - PA SYSTEM

EY106 B2 - SECOND FLOOR PLAN - PA SYSTEM

EY107 B2 - THIRD FLOOR PLAN - PA SYSTEM

EY108 B2 - FOURTH FLOOR PLAN - PA SYSTEM

EY109 B2 - FIFTH FLOOR PLAN - PA SYSTEM

EY110 B3 - BASEMENT PLAN - PA SYSTEM

EY111 B3 - FIRST FLOOR PLAN - PA SYSTEM

EY112 B3 - SECOND FLOOR PLAN - PA SYSTEM

EY113 B3 - THIRD FLOOR PLAN - PA SYSTEM

EY114 B3 - FOURTH FLOOR PLAN - PA SYSTEM

EY115 B4 - BASEMENT PLAN - PA SYSTEM

EY116 B4 - FIRST FLOOR PLAN - PA SYSTEM

EY117 B4 - SECOND FLOOR PLAN - PA SYSTEM

EY118 B4 - THIRD FLOOR PLAN - PA SYSTEM

EY119 B4 - FOURTH FLOOR PLAN - PA SYSTEM

EY120 B5 - BASEMENT PLAN - PA SYSTEM

EY121 B5 - FIRST FLOOR PLAN - PA SYSTEM

EY122 B6 - BASEMENT PLAN - PA SYSTEM

EY123 B6 - FIRST FLOOR PLAN - PA SYSTEM

EY124 B7 - FIRST FLOOR PLAN - PA SYSTEM

EY125 B8 - BASEMENT AND FIRST FLOOR PLAN - PA SYSTEM

EY126 B8 - SECOND FLOOR PLAN - PA SYSTEM

EY127 B8 - THIRD FLOOR PLAN - PA SYSTEM

EY128 B9 - FIRST FLOOR PLAN - PA SYSTEM

EY129 B9 - SECOND FLOOR PLAN - PA SYSTEM

EY130 B11 - BASEMENT PLAN - PA SYSTEM

EY131 B11 - FIRST FLOOR PLAN - PA SYSTEM

EY132 B11A,B11B,B11C - FIRST FLOOR PLAN - PA SYSTEM

EY133 B12 - FIRST AND SECOND FLOOR PLAN - PA SYSTEM

EY134 B13 - FIRST FLOOR PLAN - PA SYSTEM

EY135 B13 - SECOND FLOOR PLAN - PA SYSTEM

EY136 B14E - FIRST AND SECOND FLOOR PLANS - PA SYSTEM

EY137 B14W - FIRST AND SECOND FLOOR PLANS - PA SYSTEM

EY138 B15 - BASEMENT, FIRST, AND SECOND FLR. PLANS - PA SYSTEM

EY139 B16 - BASEMENT AND FIRST FLOOR PLANS - PA SYSTEM

EY140 B17 - FIRST FLOOR PLAN - PA SYSTEM

EY141 B18 - FIRST FLOOR PLAN - PA SYSTEM

EY142 B19 - FIRST FLOOR PLAN - PA SYSTEM

EY143 B20 - BASEMENT PLAN - PA SYSTEM

EY144 B20 - FIRST FLOOR PLAN - PA SYSTEM

EY145 B20 - SECOND FLOOR PLAN - PA SYSTEM

EY146 B21 - BASEMENT PLAN - PA SYSTEM

EY147 B21 - FIRST FLOOR PLAN - PA SYSTEM

EY148 B21 - SECOND FLOOR PLAN - PA SYSTEM

EY149 B21A, B21B - FIRST FLOOR PLAN - PA SYSTEM

EY150 B28 & B31 - FIRST FLOOR PLAN - PA SYSTEM

EY151 B42 - BASEMENT PLAN - PA SYSTEM

EY152 B42 - FIRST FLOOR PLAN - PA SYSTEM

EY153 B42 - SECOND FLOOR PLAN - PA SYSTEM

EY154 B43 - FIRST FLOOR PLAN - PA SYSTEM

E-501 ELECTRICAL DETAILS

E-601 BUILDING PA INTERCONNECTION DIAGRAM

PROJECT LOCATION

© Google Maps

PROJECT SITE

Revisions Date

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

BLDG BUILDING

C CONDUIT

CLG CEILING

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUE

CU COPPER

DB DECIBEL OR DIRECT BURIAL

DEMO DEMOLITION

DN DOWN

DWG DRAWING

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

ETR EXISTING TO REMAIN

ELECTRICAL ABBREVIATIONS

FT FEET OR FOOT

GND GROUND

LV LOW VOLTAGE

MAX MAXIMUM

MH MANHOLE

MIN MINIMUM

MTD MOUNTED

MTG MOUNTING

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

PA PUBLIC ADDRESS

PVC POLYVINYL CHLORIDE (PLASTIC)

RGS RIGID GALVANIZED STEEL

RM ROOM

REQD REQUIRED

SF SQUARE FOOT (FEET)

SPEC SPECIFICATION

TYP TYPICAL

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

V VOLT

VA VOLT AMPERE

VOLT VOLTAGE

W WATT

WP WEATHERPROOF

ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION

AWG AMERICAN WIRE GAUGE

NA NOT APPLICABLE

NEW (HEAVY, SOLID LINE)

EXISTING TO REMAIN (LIGHT, SOLID LINE)

EXISTING TO BE REMOVED (HEAVY, DASHED LINE)

ELECTRICAL SYMBOLS - POWER/LIGHTING PLANS

SYMBOL DESCRIPTION

DN

UP

CONDUIT TURNING DOWN

CONDUIT TURNING UP

CEILING MOUNTED PUBLIC ADDRESS SYSTEM SPEAKERS

MH EXISTING MANHOLE

WALL MOUNTED PUBLIC ADDRESS SYSTEM SPEAKERS

PB PULL BOX

WPB WALL PULL BOX

ELECTRICAL GENERAL NOTES

APPLICABLE CODES

1. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), INCLUDING (BUT NOT LIMITED TO):

a. NATIONAL ELECTRICAL CODE (NEC), NFPA 70 - 2023

b. NATIONAL FIRE ALARM CODE, NFPA 72 - 2022

c. LIFE SAFETY CODE, NFPA 101 – 2021

2. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), INCLUDING (BUT NOT LIMITED TO):

a. NATIONAL ELECTRICAL SAFETY CODE, ANSI C2

3. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)

4. FEDERAL COMMUNICATION COMMISSION (FCC)

5. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

6. INSULATED CABLE ENGINEERS ASSOCIATION (ICEA)

7. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)

8. NATIONAL ELECTRICAL TESTING ASSOCIATION (NETA)

9. AMERICAN SOCIETY OF TESTING AND MATERIALS (ASTM)

10. ANTI-FRICTION BEARING MANUFACTURERS ASSOCIATION (AFBMA)

11. BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. (BOCA)

12. INTERNATIONAL CODE COUNCIL (ICC):

a. INTERNATIONAL BUILDING CODE (IBC)

13. UNIFORM BUILDING CODE (UBC)

14. INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS (ICBO)

a. INTERNATIONAL ENERGY CONSERVATION CODE (IECC), ENDORSED BY THE U.S. DEPARTMENT OF ENERGY (DOE)

15. NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION INSTALLATION STANDARDS (NECA)

16. AMERICANS WITH DISABILITIES ACT (ADA)

17. APPLICABLE STATE AND LOCAL CODES, AMENDMENTS, REGULATIONS, AND PRACTICES.

18. APPLICABLE REGULATORY REQUIREMENTS AND ADVISORY PRACTICES OF APPROPRIATE

a. AUTHORITIES HAVING JURISDICTION (AHJs).

19. APPLICABLE STANDARDS, REGULATIONS, AND PRACTICES OF THE OWNER.

1. THE DRAWINGS AND APPLICABLE SPECIFICATIONS SHALL BE CONSIDERED SUPPLEMENTARY, ONE TO THE OTHER AND ARE CONSIDERED THE "CONTRACT DOCUMENTS". ALL WORKMANSHIP, METHODS AND/OR MATERIALS DESCRIBED OR IMPLIED BY ONE AND NOT DESCRIBED OR IMPLIED BY THE OTHER SHALL BE PROVIDED, FURNISHED OR PERFORMED AS IF IT HAD APPEARED IN BOTH SECTIONS. THE TERM "CONTRACT DOCUMENTS" DESCRIBED HEREIN IS NOT LIMITED SOLELY TO THE ELECTRICAL PORTION OF THE DRAWINGS AND SPECIFICATIONS, BUT

ENCOMPASSES THE DRAWINGS AND SPECIFICATIONS OF ALL DIVISIONS AS A WHOLE.

2. PROVIDE AN OPERATING AND MAINTENANCE MANUAL TO OWNER PRIOR TO THE FINAL ACCEPTANCE. THE MANUAL SHALL INCLUDE, AS A MINIMUM, (1) SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. ALSO PROVIDE TWO OPERATIONS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS AND METHOD OF OPERATION FOR EQUIPMENT SHALL BE CLEARLY IDENTIFIED, AND THE NAME, PHONE NUMBER AND

ADDRESS OF AT LEAST ONE QUALIFIED SERVICE AGENCY.

3. INCLUDE ALL COSTS FOR EXCAVATION, SAW CUTTING, DIRECTIONAL BORING, CORE DRILLING, BACKFILLING, SURFACE RESTORATION, REPAIR OF FINISHES, ETC. THAT IS REQUIRED IN ORDER TO MEET THE PROJECT

REQUIREMENTS.

4. INCLUDE IN BID THE TRANSPORT AND DISPOSAL OR RECYCLING OF ALL WASTE MATERIALS GENERATED BY THIS PROJECT IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL RULES, REGULATIONS AND GUIDELINES APPLICABLE. COMPLY FULLY WITH LOCAL STATUTES REGARDING MERCURY-CONTAINING DEVICES, AND WITH ALL DEP AND EPA APPLICABLE GUIDELINES AT THE TIME OF DISPOSAL. PROVIDE OWNER WITH WRITTEN CERTIFICATION

OF ACCEPTED DISPOSAL.

5. ALL WORK ON THE SYSTEM REQUIRED BY THE CONTRACT DOCUMENTS SHALL BE COORDINATED WITH THE WORK OF ALL OTHER DIVISIONS/TRADES PRIOR TO COMMENCEMENT OF WORK. AVOID INTERFERENCES WITH THE

PROGRESS OF OTHER DIVISIONS/TRADES.

6. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS. PROVIDE COMPONENTS

INDICATED ON RISER DIAGRAMS WHETHER OR NOT INDICATED ON PLANS AND VICE VERSA.

7. ROUTING OF CONDUIT IS DIAGRAMMATIC AND NOT INTENDED TO SHOW REQUIRED OFFSETS AND DETAILS.

COORDINATE EXACT ROUTING WITH FIELD CONDITIONS AND OTHER TRADES.

8. WHERE A DISCREPANCY OR CONFLICT IS FOUND BETWEEN ONE DRAWING AND ANOTHER, OR BETWEEN A DRAWING AND APPLICABLE SPECIFICATIONS, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY IN WRITTEN FORM. IN GENERAL, THE MOST STRINGENT REQUIREMENT SHALL GOVERN UNLESS THE DISCREPANCY CONFLICTS WITH APPLICABLE CODES OR OWNER'S DESIGN STANDARDS, WHEREIN THE CODE OR OWNER'S DESIGN STANDARDS SHALL GOVERN.

9. COORDINATE ALL PROJECT SCHEDULING AND PHASING REQUIREMENTS WITH ARCHITECT/ENGINEER AND OWNER PRIOR TO SUBMITTING BID PRICE. THIS PROJECT MAY REQUIRE PHASING SEQUENCES AND POTENTIAL PREMIUM TIME WORK AND ALL COSTS FOR SUCH SHALL BE INCLUDED IN THE BID PRICE. PROVIDE ADEQUATE WORK FORCE AND EQUIPMENT, AND INCLUDE PREMIUM TIME AS MAY BE REQUIRED IN ORDER TO ADHERE TO THE PROJECT SCHEDULE. ADDITIONALLY, ENSURE THAT LONG LEAD ITEMS DO NOT IMPACT THE PROJECT'S SCHEDULE OR

PHASING.

10. ANY TEMPORARY INTERRUPTION ON SYSTEM REQUIRED FOR THE SYSTEM TIE-IN OR SWITCHOVER FOR ANY PORTION OF THE ELECTRICAL SYSTEM SHALL BE PRE-APPROVED IN WRITING BY THE OWNER AND SCHEDULED IN

ADVANCE.

11. COORDINATE EXACT REQUIREMENTS WITH THE LOCAL UTILITY COMPANIES AND PROVIDERS (ELECTRIC, TELEPHONE, CABLE TV, ETC.) AND INCLUDE ALL COSTS FOR PROVIDING TEMPORARY AND PERMANENT SERVICES REQUIRED FOR THIS PROJECT IN THE BID PRICE. BID PRICE SHALL INCLUDE, BUT NOT BE LIMITED TO, EXCAVATION, RACEWAYS, BACKFILL, EQUIPMENT, EQUIPMENT PADS, BACKBOARDS, METERS, GROUNDING, UTILITY ENGINEERING

AND IMPACT FEES.

12. CONDUCT WORK OPERATIONS AND DEBRIS REMOVAL IN A MANNER THAT ENSURES MINIMUM INTERFERENCE WITH NORMAL BUSINESS OPERATIONS, TRAFFIC, PARKING, ETC. ONGOING IN ADJACENT OCCUPIED SPACES OR FACILITIES. PROVIDE ALL THAT IS REQUIRED TO EFFECTIVELY PROTECT SURROUNDING OCCUPANTS, EQUIPMENT, FINISHES, FURNITURE, ETC. FROM DAMAGE OR EXCESSIVE NOISE THROUGHOUT THE DURATION OF THIS PROJECT.

CONTRACTOR IS RESPONSIBLE FOR ANY LOSSES OR DAMAGE. ANY DAMAGE RESULTING FROM THE FAILURE TO ADHERE TO THIS REQUIREMENT. RESTORE DAMAGED ELEMENTS TO ORIGINAL CONDITION BY THE CONTRACTOR TO THE SATISFACTION OF THE ARCHITECT/ENGINEER AND OWNER, AT NO ADDITIONAL COSTS. REPORT OF ANY SUCH OCCURRENCE TO THE ARCHITECT/ENGINEER AND OWNER IMMEDIATELY AND AWAIT WRITTEN DIRECTION PRIOR TO

PROCEEDING WITH REPAIRS.

13. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO 6' ABOVE EQUIPMENT OR STRUCTURAL CEILING, WHICHEVER DISTANCE IS LOWER, WITH A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING, DUCTS, EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL

APPURTENANCES IN ACCORDANCE WITH NEC.

14. THE INFRASTRUCTURE FOR THE VOICE/DATA TELECOMMUNICATIONS SYSTEM (CONDUITS, ELECTRICAL BOXES) SHALL BE INSTALLED BY DIVISION 26. THE TELECOMMUNICATIONS CONTRACTOR SHALL PROVIDE AND INSTALL THE WIRE AND CABLE FOR THE SYSTEM AND ALL REQUIRED EQUIPMENT AND COMPONENTS. INSTALLATION OF THE CONDUITS AND ELECTRICAL BOXES SHALL BE UNDER THE DIRECT SUPERVISION OF THE TELECOMMUNICATIONS CONTRACTOR. COORDINATE EXACT LOCATIONS OF DEVICES, RACEWAY LOCATIONS, SIZES AND QUANTITY, CONDUIT

STUB-UPS PRIOR TO ROUGH IN.

15. UNLESS NOTED AS EXISTING, ALL ELECTRICAL INDICATED ON THE CONTRACT DOCUMENTS SHALL BE NEW, SHALL BE U.L.

LISTED, AND SHALL BEAR A U.L. LABEL. WHERE NO U.L. LABEL OR LISTING IS AVAILABLE, THE MATERIAL SHALL BE LISTED

WITH AN APPROVED, NATIONALLY RECOGNIZED ELECTRICAL TESTING AGENCY.

16. PROVIDE EXPERIENCED, QUALIFIED AND RESPONSIBLE SUPERVISION FOR ALL WORK REQUIRED BY THE CONTRACT DOCUMENTS. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, TO THE

SATISFACTION OF THE ARCHITECT/ENGINEER AND OWNER.

17. THE ELECTRICAL PORTION OF THE CONTRACT DOCUMENTS ARE COORDINATED WITH THE DESIGN BASIS EQUIPMENT SPECIFIED BY DIVISION 26 AND OTHER DIVISIONS. WHERE THE CONTRACTOR ELECTS TO SUBSTITUTE A PRODUCT IN LIEU OF PROVIDING THE DESIGN BASIS, AND SAID SUBSTITUTION IS ACCEPTED BY THE A/E AND OWNER, THE CONTRACTOR SHALL MAKE ALL CORRECTIONS TO THE ELECTRICAL SYSTEM NECESSARY IN ORDER TO ENSURE A COMPLETE AND OPERATIONAL INSTALLATION OF THE EQUIPMENT AT NO ADDITIONAL COSTS. WHERE THE CONTRACTOR'S DESIGN SUBSTITUTION RESULTS IN THE NEED FOR THE ENGINEER TO REVISE THE CONTRACT DOCUMENTS, THE ENGINEER RESERVES THE RIGHT TO

REQUEST COMPENSATION FROM THE CONTRACTOR FOR SAID SERVICES.

18. MAINTAIN A CURRENT AND ACCURATE SET OF PROJECT RECORD DOCUMENTS (AS-BUILTS) AT THE SITE THROUGHOUT THE DURATION OF THE PROJECT. RECORD DRAWINGS SHALL BE UPDATED EACH DAY TO REFLECT THE ACTUAL LOCATIONS, SIZES, ROUTING, ETC. OF EACH PORTION OF THE ELECTRICAL SYSTEM AFFECTED BY THIS WORK. A FINAL SET OF RECORD DOCUMENTS SHALL BE ISSUED TO THE A/E FOR REVIEW AND THEN SUBMITTED TO THE OWNER WITHIN 30 DAYS AFTER THE DATE OF FINAL ACCEPTANCE. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION INCLUDING SINGLE LINE

DIAGRAM.

19. OWNER FURNISHED EQUIPMENT: VERIFY AND COORDINATE ROUGH IN REQUIREMENTS FOR OWNER FURNISHED EQUIPMENT

PRIOR TO ROUGH IN.

20. EXISTING ROLLING CABINETS SHALL BE CLEANED PRIOR TO REUSE.

ELECTRICAL DEMOLITION NOTES

THE FACILITY WILL REMAIN OCCUPIED DURING RENOVATIONS.

DEVICES, AND EQUIPMENT SHOWN IN DASHED LINE TYPE ARE EXISTING TO BE DEMOLISHED; DEVICES AND EQUIPMENT SHOWN IN

LIGHT SOLID LINE TYPE ARE EXISTING TO REMAIN, UNLESS OTHERWISE NOTED.

EXISTING EQUIPMENT, DEVICES SHOWN ARE BASED ON FIELD SURVEYS AND RECORD DRAWINGS PROVIDED BY THE OWNER, AND IS NOT NECESSARILY ALL INCLUSIVE IN EVERY AREA AS FAR AS EXISTING ELECTRICAL EQUIPMENT AND DEVICES. EXISTING CIRCUITING SHOWN IS BASED ON RECORD DRAWINGS AND THE SURVEYED PANEL DIRECTORIES, WHERE THEY WERE AVAILABLE.

THE ACTUAL CONDITIONS MAY VARY. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO BID. THE CONDITIONS SHOWN ARE INTENDED TO SHOW THE LOCATIONS OF EXISTING DEVICES, LIGHT FIXTURES AND EQUIPMENT, WHERE SHOWN ON THE PLAN DRAWINGS, AND IN NO WAY RELIEVES THE CONTRACTOR FROM PROVIDING ANY AND ALL COORDINATION NECESSARY TO

COMPLETE THE NEW WORK. FIELD CONDITIONS SHALL GOVERN.

WHERE EXISTING DEVICES ARE INDICATED TO REMAIN OR RELOCATED, LOCATED WITHIN THE SCOPE OF THIS PROJECT AND EXISTING CIRCUITING INFORMATION IS UNAVAILABLE, CONTRACTOR IS TO PROVIDE CIRCUIT TRACING TO IDENTIFY PANEL AND CIRCUIT DEVICES ARE CONNECTED TO AND PROVIDE THAT INFORMATION TO A/E PRIOR TO ROUTING CONDUITS AND WIRING FOR

NEW DEVICES AND EQUIPMENT WITHIN THE SCOPE OF THIS PROJECT.

PRIOR TO DEMOLITION, FIELD VERIFY CONDUIT AND WIRING WHICH SERVES AREAS OUTSIDE THE SCOPE OF WORK AND PASSES

THROUGH THE AREA OF WORK. MAINTAIN CONTINUITY OF SYSTEMS.

COORDINATE WITH THE OWNER FOR DISPOSITION OF ELECTRICAL ITEMS TO BE DEMOLISHED. OWNER SHALL HAVE THE OPTION TO RETAIN REUSABLE ITEMS. COORDINATE WITH THE OWNER PRIOR TO START OF DEMOLITION. PROPERLY AND LEGALLY

DISPOSE OF ALL EQUIPMENT AND MATERIALS BEING REMOVED.

COORDINATE EXACT AREAS, WALLS, CEILINGS, ETC. TO BE DEMOLISHED WITH ARCHITECTURAL, STRUCTURAL, PLUMBING AND

MECHANICAL DEMOLITION PLANS.

REMOVE ALL CONDUIT LEFT EXPOSED BY REMOVAL OF WALLS AND CEILINGS IN REMODELED OR RENOVATED AREA. CAP BOTH ENDS OF REMAINING CONDUIT IN WALL OR FLOOR WHERE CUT. REMOVE ALL ASSOCIATED SUPPORTS. REMOVE WIRING BACK TO

SOURCE OF VOLTAGE.

CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING ALL OPENINGS IN EXISTING CONSTRUCTION AFTER REMOVAL OF EQUIPMENT AND ELECTRICAL DEVICES, UNLESS OTHERWISE NOTED ON ARCHITECTURAL PLANS. REPAIRS ARE TO BE DONE TO LOGICAL EDGES OF SURFACES AFFECTED AND SHALL MATCH IMMEDIATE ADJACENT AREAS IN CONSTRUCTION, MATERIAL, FIRE

RATING, FINISH AND COLOR.

PROVIDE BLANK COVERPLATES WHERE DEVICES ARE BEING REMOVED FROM EXISTING WALLS TO REMAIN. MATCH COLOR OF

NEW ADJACENT DEVICE COVERPLATES.

FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF WORK AND OBTAIN CLARIFICATIONS

FROM ARCHITECT/ENGINEER IF NECESSARY.

EXERCISE EXTREME CAUTION WHEN REMOVING/ RELOCATING WIRING AND EQUIPMENT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT OTHER WIRING DEVICES, EQUIPMENT AND LIGHT FIXTURES THAT MAY BE CONNECTED TO THE

SAME CIRCUIT REMAIN OPERATIONAL AND ACTIVE.

INFORMATION INDICATED IN THE DEMOLITION PORTION OF THE CONTRACT DRAWINGS IS DIAGRAMMATIC IN NATURE. FIELD VERIFY ELECTRICAL CIRCUIT HOMERUNS TO ALL ELECTRICAL ITEMS SCHEDULED TO BE DEMOLISHED AND PERFORM THE WORK

AS INTENDED AND DEPICTED ON THE DRAWINGS.

UPDATE ALL EXISTING ELECTRICAL EQUIPMENT NAMEPLATES AND DIRECTORIES AS NECESSARY TO REFLECT FINAL AS-BUILT

CONDITIONS AT THE END OF CONSTRUCTION.

STORE ITEMS INDICATED TO BE RETURNED TO THE OWNER IN A DRY, CLEAN AND PROTECTED AREA. NOTIFY OWNER WHEN ITEMS

ARE READY TO BE REMOVED.

PROVIDE ANY NECESSARY REPROGRAMMING OF EXISTING BUILDING FIRE ALARM SYSTEMS TO DISABLE FIRE ALARM DEVICES THAT ARE BEING DISCONNECTED AND REMOVED, AND FOR ANY NEW DEVICES THAT ARE ADDED, AS PART OF BID PRICE.

THE DEMOLITION PLAN IS NOT INCLUSIVE OF ALL ELECTRICAL DEVICES WITHIN THE PROJECT AREA. IT IS INTENDED TO PROVIDE A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. ANY DISCREPANCIES OR CONDITIONS NOT SHOWN ON THE PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE A/E. THE CONTRACTOR IS RESPONSIBLE FOR ALL

REQUIRED ELECTRICAL DEMOLITION WHETHER INDICATED ON THE PLANS OR NOT.

ALL CONDUITS SERVING OTHER SPACES THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE DISRUPTION TO THESE OTHER SPACES. ENSURE THAT ALL CONDUITS, NEW OR EXISTING WITHIN THE PROJECT AREA ARE PROPERLY SUPPORTED IN ACCORDANCE WITH THE NEC. ANY EXISTING CONDUIT IS INSTALLED BELOW THE HEIGHT OF THE NEW CEILING SHALL BE RELOCATED TO ABOVE THE NEW CEILING HEIGHT.

REMOVE ALL ABANDONED WIRING AND CONDUIT THAT IS WITHIN THE PROJECT AREA PRIOR TO THE END OF CONSTRUCTION.

REPAIR DISTURBED AREAS TO MATCH EXISTING CONDITIONS

D1 D2

D3

D4

D5

D6

D7

D8

D9

D10

D11

D12

D13

D14

D15

D16

D17

D18

D19 D20

1. CONTRACTOR SHALL REFER TO SPECIFICATION 01 35 26 FOR ICRA REQUIREMENTS AND

INFECTION CONTROL. REFER TO TABLE WITHIN SPECIFICATION FOR LEVEL REQUIRED FOR

EACH BUILDING AS PART OF THIS PROJECT.

2. CONTRACTOR SHALL PROVIDE NEW CEILING TILES THAT ARE DAMAGED AS PART OF THE

RENOVATION PER SPECIFICATION 01 00 00.

3. CONTRACTOR SHALL COORDINATE WITH VAMC COR AND STAFF FOR NUMBER OF CEILING

TILES TO BE REMOVED DURING DEMOLITION AND INSTALLATION OF CONDUIT. REFER TO

SPECIFICATION 01 35 26

4. INSTALL NEW CABLING IN EXPOSED CONDUIT IN CRAWL SPACES, ELECTRICAL AND

MECHANICAL ROOMS AND TUNNELS. ASSUME CABLING WILL BE INSTALLED CONCEALED

ABOVE SUSPENDED ACOUSTIC CEILING IN ALL OTHER SPACES UNLESS OTHERWISE NOTED.

5. FOR LOCATIONS WITH GYPSUM BOARD CEILINGS OR PLASTER LATHE CEILINGS,

CONTRACTOR SHALL CUT AND REMOVE PORTIONS OF THE CEILINGS AS REQUIRED TO

ALLOW FOR REMOVAL OF CONDUIT AND INSTALLATION OF NEW WORK. UPON COMPLETION

OF WORK, CONTRACTOR SHALL REPAIR CEILINGS TO MATCH EXISTING CONDITIONS AS

REQUIRED FOR CEILING CONSTRUCTION.

SPECIAL GENERAL NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:3

:5

A

M

E-001

ELECTRICAL LEGENDS &

SYMBOLS

VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

11A,11B,11C

14E

14W

16,17,18,28

21A,21B

ZONE # BLDGS

ONE BUTTON WILL CALL FOR SELECTED ZONES IN YELLOW:

CODE RED, CODE BLUE, CODE SILVER, CODE ORANGE & CODE RAPID RESPONSE

"CODE" BUTTON

ONE BUTTON WILL CALL FOR ALL ZONES:

CODE ADAM, CODE DELTA, CODE DELTA DECON, CODE BLACK, ACTIVE SHOOTER

"EMERGENCY" BUTTON

* CODE AND EMERGENCY BUTTONS SHOULD HAVE THE OPTION TO SUBTRACT

A ZONE WHEN DESIRED

* MULTI BUTTON STATIONS SHOULD ALLOW USERS TO SELECT MORE THAN

ONE ZONE WHEN DESIRED

ZONE TABLE

* COORDINATE ZONE CALLING REQUIREMENTS WITH VA

Revisions Date

1 ADDENDUM #1 12/01/23

H O S

PITAL AC

C

ESS R

O

AD

CEMETERY ACCESS ROAD

CEMETERY ACCESS ROAD

S T

A T

E S

V

IL

L E

A V

E

D

R

I

V

E

"J

D R I V E "A"

M A I N M A I N

M A I N

M

A

N

D

R

I

"B

D

R

I

"G

E

X

T

E

N

T R

A N

C

D R

"H"I V E

D R I V E

"L

D

R

"M

D R I V E "K"

D

R

I

"C

"W

"V"

"D

D R I V E "D"

D

R

I

"E

M A I N

D

IVE

"F"

"N

D R

IVE

"R

DRIVE "P"

D

"Z

N

N

LOT 21

LOT 11

LOT 12

LOT 19

LOT 1

LOT 2

LOT 13

LOT 21

LOT 13

LOT 1

LOT 42

LOT 7

LOT 7

LOT 6

LOT 43

LOT 21

NATIONAL CEMETERY

NATIONAL CEMETERY

OFFICES

SmokingShelter

S T

R E

E T

H E

D R

IC

K

AVENUEBRENNER

S T

R E

E T

H E

D R

IC

K

A C

K E

R T

A V

E

S . M

E R

R I T

T

S . L

IN

K

O V

E R

M A

N

F A

IR

S

P

R K

IN

G

G A R A G E

A V

E

A V

E

A V

E

A V

E

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TUNNEL C

TUNNEL E

TUNNEL G

TUNNEL F

TUNNEL A

TUNNEL 1 & 2

TUNNEL B

11A

11B

11C

21A

21B

14E

14W

17C

17B17A

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

MAIN CAMPUS PA SOURCE EQUIPMENT

TELECOM ROOM

TUNNEL C

TUNNEL E

TUNNEL G

TUNNEL F

TUNNEL A

TUNNEL 1 & 2

TUNNEL B

MH

MH MH

MH

MH MH

ZONE 24

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

BUILDINGS

20. CLINICAL LAB

21. ENDOSCOPE, PODIATRY,

ONCOLOGY, SLEEP CLINIC

21A. FEE BASICS

21B. ENGINEERING

22. FLAG POLE

23.

24. R.M.&S STORAGE

25. R.M.&S STORAGE

28. ENGINEERING PAINT SHOT

29. R.M.&S STORAGE

30. GREENHOUSE

31. CHILLER PLAN

32. GENERATOR BUILDING

33. SWITCHGEAR BUILDING

34. GENERATOR BUILDING

35. GENERATOR BUILDING

36. GENERATOR BUILDING

37. GENERATOR BUILDING

38. GENERATOR BUILDING

39. PICNIC SHELTER

40. GROUNDS STORAGE SHELTER

42. GERO-PSYCHIATRIC BUILDING

43. HOSPICES BUILDING

1. ADMINISTRATION BUILDING

2. G. M. & S BUILDING

3. OUTPATIENT CLINICS

4. PATIENT TREATMENT(MENTAL HEALTH)

5. MAIN KITCHEN

6. RECREATION BUILDING

7. R.M.S & CORE CLINIC BUILDING

8. PATIENT TREATMENT(MENTAL HEALTH)

9. PARKING GARAGE

10. N.C. VETERANS HOME

11. MENTAL HEALTH OFFICES

11A. MENTAL HEALTH OFFICES

11B. MENTAL HEALTH OFFICES

11C. MENTAL HEALTH OFFICES

12. POLICE HEADQUARTERS

13. STUDENT LODGING

14. E&W DUPLEX QUARTERS

15. VISIN

16. LAUNDRY

17. WAREHOUSE

17A. WAREHOUSE

17B. EM WAREHOUSE

17C. GSA VEHICLES

18. BOILER PLANT

19. CHAPEL

MH

MH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:4

A

M

ED100

ELECTRICAL SITE PLAN - DEMO VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

1" = 100'-0"1

SITE PLAN - ELECTRICAL DEMOLITION WORK

N

0 50' 100' 200' 300'

1" = 100'

CODED NOTES:

DRAWING NOTES:

1. AFTER NEW FIBER OPTIC CABLE HAS BEEN INSTALLED TO EACH BULDING, CONTRACTOR SHALL

DISCONNECT UPSTREAM DATA NETWORK CABLING FROM EACH BUILDING'S PA HEAD END

EQUIPMENT BACK TO SOURCE LOCATED IN BUILDING 5 TELECOM ROOM. EMPTY CONDUIT SHALL

REMAIN. INSTALL PULL STRING THROUGHOUT LENGTH OF CONDUIT.

2. UNLESS OTHERWISE NOTED ALL MANHOLES ARE EXISTING TO REMAIN.

3. ALL UNUSED CONDUIT IN EXPOSED OR DROP CEILINGS SHALL BE REMOVED IN THE TUNNELS AND

COVERED WALKWAYS.

4. CONTRACTOR SHALL VERIFY THE EXACT ROUTING OF EXACT ROUTING OF EXISTING CONDUITS IN

FIELDS.

1 EXISTING PULL BOX/CABINET LOCATED IN TUNNEL SHALL BE USED TO ROUTE UNDERGROUND

CABLING TO EXISTING MANHOLE.

2 EXISTING UNDERGROUND CONDUIT SHALL BE USED FOR NEW WORK. FIELD VERIFY EXACT

LOCATION.

3 DISCONNECT AND REMOVE EXISTING LOW VOLTAGE WIRING COMPLETE FROM PA EQUIPMENT BACK

TO MAIN CAMPUS PA SOURCE EQUIPMENT LOCATED IN BUILDING 5. CONDUIT SHALL REMAIN.

4 DISCONNECT AND REMOVE EXISTING LOW VOLTAGE WIRING COMPLETE FROM PA EQUIPMENT BACK

TO PA SOURCE EQUIPMENT LOCATED IN BUILDING 2. CONDUIT SHALL REMAIN.

5 DISCONNECT AND REMOVE EXISTING LOW VOLTAGE WIRING COMPLETE FROM PA EQUIPMENT BACK

TO PA SOURCE EQUIPMENT LOCATED IN BUILDING 4. CONDUIT SHALL REMAIN.

H

S

PITAL AC

C

ESS R

O

AD

CEMETERY ACCESS ROAD

CEMETERY ACCESS ROAD

S T

A T

E S

V

IL

L E

A V

E

"J

D R I V E "A"

M A I N M A I N

M A I N

N

D

R

I

"B

D

R

I

"G

E

X

T

E

N

T R

A N

C

D R

"H"I V E

D R I V E

"L

D

R

"M

D R I V E "K"

D

R

I

"C

"W

"V"

"D

D R I V E "D"

D

R

I

"E

M A I N

D

"F"

"N

D R

IVE

"R

DRIVE "P"

D

"Z

N

LOT 21

LOT 11

LOT 12

LOT 19

LOT 1

LOT 2

LOT 13

LOT 21

LOT 13

LOT 1

LOT 42

LOT 7

LOT 7

LOT 6

LOT 43

LOT 21

NATIONAL CEMETERY

NATIONAL CEMETERY

OFFICES

SmokingShelter

S T

R E

E T

H E

D R

IC

K

AVENUEBRENNER

S T

R E

E T

H E

D R

IC

K

A C

K E

R T

A V

E

S . M

E R

R I T

T

S . L

IN

K

O V

E R

M A

N

F A

IR

S

P

R K

IN

G

G A R A G E

A V

E

A V

E

A V

E

A V

E

ZONE 1

11A

11B

11C

21A

21B

14E

14W

17C

17B17A

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

MH

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

MAIN CAMPUS PA SOURCE EQUIPMENT

TELECOM ROOM

MH

TUNNEL C

TUNNEL E

TUNNEL G

TUNNEL F

TUNNEL A

TUNNEL 1 & 2

ZONE 20

ZONE 10

ZONE 4

ZONE 18

ZONE 2

ZONE 5

ZONE 3

ZONE 6

ZONE 23

ZONE 7

TUNNEL B

MH

MH MH

MH

ZONE 17

ZONE 17

ZONE 17

ZONE 16

ZONE 11

ZONE 11

ZONE 11

ZONE 8

ZONE 13

ZONE 12

ZONE 14

ZONE 15

ZONE 19

ZONE 9

MH MH

ZONE 22

. 4

ZONE 17

ZONE 21

ZONE 21

TUNNEL

ZONE 24

14 17

TELECOM ROOM 14

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

BUILDINGS

20. CLINICAL LAB

21. ENDOSCOPE, PODIATRY,

ONCOLOGY, SLEEP CLINIC

21A. FEE BASICS

21B. ENGINEERING

22. FLAG POLE

23.

24. R.M.&S STORAGE

25. R.M.&S STORAGE

28. ENGINEERING PAINT SHOT

29. R.M.&S STORAGE

30. GREENHOUSE

31. CHILLER PLAN

32. GENERATOR BUILDING

33. SWITCHGEAR BUILDING

34. GENERATOR BUILDING

35. GENERATOR BUILDING

36. GENERATOR BUILDING

37. GENERATOR BUILDING

38. GENERATOR BUILDING

39. PICNIC SHELTER

40. GROUNDS STORAGE SHELTER

42. GERO-PSYCHIATRIC BUILDING

43. HOSPICES BUILDING

1. ADMINISTRATION BUILDING

2. G. M. & S BUILDING

3. OUTPATIENT CLINICS

4. PATIENT TREATMENT(MENTAL HEALTH)

5. MAIN KITCHEN

6. RECREATION BUILDING

7. R.M.S & CORE CLINIC BUILDING

8. PATIENT TREATMENT(MENTAL HEALTH)

9. PARKING GARAGE

10. N.C. VETERANS HOME

11. MENTAL HEALTH OFFICES

11A. MENTAL HEALTH OFFICES

11B. MENTAL HEALTH OFFICES

11C. MENTAL HEALTH OFFICES

12. POLICE HEADQUARTERS

13. STUDENT LODGING

14. E&W DUPLEX QUARTERS

15. VISIN

16. LAUNDRY

17. WAREHOUSE

17A. WAREHOUSE

17B. EM WAREHOUSE

17C. GSA VEHICLES

18. BOILER PLANT

19. CHAPEL

MH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:4

A

M

EY100

ELECTRICAL SITE PLAN VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

CODED NOTES:

DRAWING NOTES:

1. THE PURPOSE OF THIS SHEET IS TO SHOW THE EXISTING AND MODIFIED CAMPUS WIDE PA NETWORK SYSTEM. EXISTING INFORMATION SHOWN IS BASED ON RECORD DRAWINGS. FIELD VERIFY EXACT

LOCATION PRIOR TO WORK.

2. UNLESS OTHERWISE NOTED ALL MANHOLES ARE EXISTING TO REMAIN.

3. REFER TO SHEET E-601, PA SYSTEM INTERCONNECTION DIAGRAM FOR ADDITIONAL INFORMATION.

4. ALL NEW SURFACE MOUNTED CONDUITS ROUTED WITHIN WALKWAYS AND TUNNELS SHALL BE

PAINTED TO MATCH EXISTING SURFACES.

5. ALL ARMOR CABLING ROUTING IN BUILDINGS WITH ACCESSIBLE CEILINGS SHALL BE SUPPORTED BY

J-HOOKS.

6. CONTRACTOR SHALL COORDINATE ROUTING OF ALL NEW CONDUITS AND CABLING WITH EXISTING

CONDITIONS AND MAKE MODIFICATIONS AS REQUIRED.

7. ALL FIBER OPTIC CABLES ROUTED IN CONDUIT SHALL BE PROTECTED BY FABIC INNERDUCT SIMILAR

TO MAXCELL EDGE 2".

1" = 100'-0"1

SITE PLAN - ELECTRICAL NEW WORK N

0 50' 100' 200' 300'

1" = 100'

1 STUB CONDUIT UP TO EXTERIOR WALL MOUNTED, 12" X 12" X 6" NEMA 3R PULL BOX AND STUB

CONDUIT THROUGH BUILDING WALL. ROUTE ARMORED FIBER OPTIC CABLING ABOVE

ACCESSIBLE CEILING AND TERMINATE INTO PA SYSTEM EQUIPMENT OR DEVICES. REFER TO

PLANS FOR PA EQUIPMENT LOCATIONS.

2 ROUTE NEW SPEAKER WIRING PER MANUFACTURERS TO RECOMMENDATION IN NEW

UNDERGROUND CONDUIT FROM NEW UPSTREAM PA SOURCE HEAD END EQUIPMENT TO SERVE

SPEAKER DEVICES IN BUILDING 17 & 28.

3 ROUTE NEW SPEAKER WIRING PER MANUFACTURERS RECOMMENDATION IN NEW

UNDERGROUND 3/4" CONDUIT FROM NEW UPSTREAM PA SOURCE HEAD END EQUIPMENT TO

SERVE SPEAKER DEVICES.

4 EXISTING CONDUIT AND WIRING SHALL BE REUSED TO CONNECT BUILDING 11A,11B AND 11C TO

BUILDING 11 PA SOURCE EQUIPMENT.

5 ROUTE NEW ARMORED FIBER OPTIC CABLE IN NEW 4" CONDUIT. TERMINATE AT MAIN CAMPUS

PA HEAD END EQUIPMENT LOCATED IN BUILDING 5. FIELD VERIFY EXACT ROUTING PRIOR TO

INSTALLATION.

6 ROUTE NEW ARMORED FIBER OPTIC CABLING IN EXISTING UNDERGROUND FIRE ALARM

CONDUIT.

7 EXISTING CONDUIT AND SPEAKER WIRING SHALL REMAIN. RECONNECT TO NEW PA HEAD END

EQUIPMENT LOCATED IN BLDG 21.

8 REUSE EXISTING SPEAKER WIRING AND CONDUIT. RECONNECT TO NEW UPSTREAM PA SOURCE

HEAD END EQUIPMENT LOCATED IN BLDG 42.

9 CONTINUE ROUTING OF NEW ARMORED FIBER OPTIC CABLE IN NEW UNDERGROUND 4" CONDUIT

FROM EXISTING MANHOLE.

10 ROUTE NEW ARMORED FIBER OPTIC CABLING THROUGH EXISTING MANHOLE.

11 ROUTE THROUGH EXISTING PULL BOX/CABINET LOCATED IN TUNNEL.

12 ROUTE ARMORED FIBER OPTIC CABLING THROUGH TUNNEL IN 4" CONDUIT.

13 ROUTE BUNDLE OF ARMORED FIBER OPTIC CABLING THROUGH TUNNEL IN 4" CONDUIT.

14 ROUTE NEW ARMORED FIBER OPTIC CABLING THROUGH TUNNEL IN NEW 4" CONDUIT.

15 ROUTE BUNDLE OF ARMORED FIBER OPTIC CABLING THROUGH TUNNEL IN 4" CONDUIT.

16 ROUTE NEW ARMORED FIBER OPTIC CABLING ABOVE CEILING AND TERMINATE INTO MAIN

CAMPUS PA SOURCE EQUIPMENT.

17 ARMORED CABLING SHALL EXIT CONDUIT UPON ENTRY INTO THE BUILDING. ROUTE ABOVE

CEILING AND TERMINATE INTO HEAD END EQUIPMENT OR PASS THROUGH AS SHOWN TO NEXT

BUILDING. REFER TO BUILDING PLANS FOR ROUTING DETAILS. THIS NOTE TYPICAL FOR ALL

BUILDINGS.

18 ROUTE NEW ARMORED FIBER OPTIC CABLING IN NEW 4" CONDUIT THROUGH COVERED

WALKWAY FROM BLDG 42 TO MAIN CAMPUS PA SOURCE EQUIPMENT LOCATED IN BUILDING 5.

19 ROUTE NEW SPEAKER WIRING PER MANUFACTURERS RECOMMENDATION IN EXISTING CONDUIT

FROM NEW UPSTREAM PA SOURCE HEAD END EQUIPMENT TO SERVE SPEAKER DEVICES.

20 ROUTE BUNDLE OF ARMORED FIBER OPTIC CABLING THROUGH TUNNEL IN 4" CONDUIT.

21 STUB CONDUIT UP TO EXTERIOR WALL MOUNTED, 12" X 12" X 6" NEMA 3R PULL BOX AND STUB

CONDUIT AND WIRING THROUGH BUILDING WALL.

22 ROUTE ARMORED FIBER OPTIC CABLING IN EXISTING UNDERGROUND CONDUIT.

G01

MECH RM

G03

MECH RM

G04

MECH RM

G02

MECH RM

G05

MECH RM

G08

OFFICE

G06

OFFICE

G09

VENDING RM.

G06C

CORR.

G07

STAIR

G10

FILE STORAGE

FEC

S

S S

S

G01

MECH RM

G03

MECH RM

S

EY101

EXISTING MANHOLE

ON LEVEL ABOVE

ARMORED FIBER OPTIC CABLING IN EXISTING CONDUIT ROUTED TO BLDG 12

EXISTING MANHOLE ON LEVEL ABOVE

ARMORED FIBER OPTIC CABLING IN EXISTING

CONDUIT, EACH ROUTED TO BLDG 1 & BLDG 12

CRAWL SPACE

1. FIELD VERIFY LOCATION OF EXISTING DATA CABLING AND PA SYSTEM EQUIPMENT PRIOR TO

WORK.

2. REFER TO SHEET E-601 FOR BUILDING PA INTERCONNECTION DIAGRAM.

3. NEW PA SOURCE EQUIPMENT SHALL HAVE BUT NOT BE LIMITED TO THE FOLLOWING FEATURES:

A. SELF CONTAINED OR ON BOARD SYSTEM PROGRAM MEMORY SHALL BE NON-VOLATILE AND

PROTECTED FROM ERASURE FROM POWER OUTAGES FOR A MINIMUM OF 24 HOURS.

B. BACKUP BATTERY OR A UPS FOR THE SYSTEM TO ALLOW NORMAL OPERATION AND FUNCTION

IN THE EVENT OF AN AC POWER FAILURE OR DURING INPUT POWER FLUCTUATIONS FOR A

MINIMUM OF TWO (2) HOURS

C. THE PA SHALL PROVIDE ZONED, ONE-WAY VOICE PAGING THROUGH DISTRIBUTED, CEILING

MOUNTED LOUDSPEAKERS. VOICE INPUT INTO THE PA SHALL BE BY ZONE USING THE

TELEPHONE SYSTEM.

D. THE SYSTEM SHALL BE ABLE TO INTERFACE WITH NURSE CALL AND FIRE ALARM.

E. THE SYSTEM SHALL INTERFACE WITH THE FACILITY’S EXISTING DATA NETWORK.

EXISTING CABINET

WITH AMPLIFIER ZONE#1

UPS (BELOW AMPLIFIER

IN MOBILE RACK) 1

4. ALL SPEAKER DEVICES ON THIS SHEET ARE EXISTING TO REMAIN. SPEAKER LOCATIONS ARE

BASED ON RECORD DRAWINGS AND FIELD OBSERVATION. CONTRACTOR TO ADD 10%

REPLACEMENT CONTINGENCY. FIELD VERIFY EXACT LOCATIONS AND QUANTITIES.

IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES. DISCONNECT ALL SPEAKERS FROM

EXISTING PA SYSTEM HEAD END EQUIPMENT AND RECONNECT TO NEW. LOW VOLTAGE

SPEAKER WIRING SHALL BE REUSED.

5. REFER TO THE SITE PLAN SHEET EY100 FOR CONTINUATION OF CONDUIT ROUTING AND SIZE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:4

A

M

EY101

B1 - BASEMENT PLAN - PA

SYSTEM

VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

N

0 8' 16' 32' 48'

1/16" = 1'-0"

1/16" = 1'-0"

B1 - BASEMENT PLAN - ELECTRICAL EQUIPMENT

CODED NOTES:

DRAWING NOTES:

1 PROVIDE NEW PA HEAD END EQUIPMENT AS SHOWN. REUSE AND REROUTE EXISTING LOW VOLTAGE

WIRING AND CONDUIT TO RECONNECT EXISTING DOWNSTREAM EQUIPMENT TO NEW PA HEAD END

EQUIPMENT. CONNECT SINGLE MODE FIBER OPTIC CABLES FROM PA HEAD END EQUIPMENT TO THE MAIN PA SOURCE EQUIPMENT LOCATION IN BUILDING 5. FIELD VERIFY PA HEAD END EQUIPMENT IS PLUGGED INTO EMERGENCY PLUGS IN RACK. CLEAN AND REUSE EXISTING ROLLING CABINET FOR

NEW EQUIPMENT.

2 ROUTE CONDUIT IN CRAWL SPACE FROM MANHOLE. CABLING TO BE SUPPORTED TO STRUCTURE

INSIDE THE BUILDING.

1/8" = 1'-0"

ENLARGED PLAN BLDG 1 MECH RM 118

0 4' 8' 16' 24'

1/8" = 1'-0"

Revisions Date

1 ADDENDUM #1 12/01/23

6. INSTALL NEW CABLING IN EXPOSED CONDUIT IN CRAWL SPACES, ELECTRICAL AND MECHANICAL

ROOMS AND TUNNELS. ASSUME CABLING WILL BE INSTALLED CONCEALED ABOVE SUSPENDED

ACOUSTIC CEILING IN ALL OTHER SPACES UNLESS OTHERWISE NOTED.

135F

OFFICE

135C

OFFICE

135C

OFFICE

135B

OFFICE

OFFICE

STAIRS#3

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

TOILET

CLOSET

TOILET

LOBBY

120A

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

108D

OFFICE

OFFICE

104A

OFFICE

108C

OFFICE

104B

OFFICE

300 108B

OFFICE

OFFICE

104C

OFFICE

MAILROOM

LOBBY

STAIRS#2

101A

KEYPUNCH

M. BOXES

103A

STORAGE

CORRIDOR

OFFICE

108A

OFFICE

TOILET

F. TOILET

OFFICE

STAIR#1

MOP

OFFICE

CORR.

102A

OFFICE

M. TLT

STORAGE

ELEVATOR

FEC

F. TOILET

M. TOILET

S

S

S S

S

S

S

S

S

S

S

S

S S

S

1. FIELD VERIFY LOCATION OF EXISTING DATA CABLING AND PA SYSTEM EQUIPMENT PRIOR TO

WORK.

2. REFER TO SHEET E-601 FOR BUILDING PA INTERCONNECTION DIAGRAM.

3. NEW PA SOURCE EQUIPMENT SHALL HAVE BUT NOT BE LIMITED TO THE FOLLOWING FEATURES:

A. SELF CONTAINED OR ON BOARD SYSTEM PROGRAM MEMORY SHALL BE NON-VOLATILE AND

PROTECTED FROM ERASURE FROM POWER OUTAGES FOR A MINIMUM OF 24 HOURS.

B. BACKUP BATTERY OR A UPS FOR THE SYSTEM TO ALLOW NORMAL OPERATION AND FUNCTION

IN THE EVENT OF AN AC POWER FAILURE OR DURING INPUT POWER FLUCTUATIONS FOR A

MINIMUM OF TWO (2) HOURS

C. THE PA SHALL PROVIDE ZONED, ONE-WAY VOICE PAGING THROUGH DISTRIBUTED, CEILING

MOUNTED LOUDSPEAKERS. VOICE INPUT INTO THE PA SHALL BE BY ZONE USING THE

TELEPHONE SYSTEM.

D. THE SYSTEM SHALL BE ABLE TO INTERFACE WITH NURSE CALL AND FIRE ALARM.

E. THE SYSTEM SHALL INTERFACE WITH THE FACILITY’S EXISTING DATA NETWORK.

4. ALL SPEAKER DEVICES ON THIS SHEET ARE EXISTING TO REMAIN. SPEAKER LOCATIONS ARE

BASED ON RECORD DRAWINGS AND FIELD OBSERVATION. CONTRACTOR TO ADD 10%

REPLACEMENT CONTINGENCY. FIELD VERIFY EXACT LOCATIONS AND QUANTITIES.

IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES. DISCONNECT ALL SPEAKERS FROM

EXISTING PA SYSTEM HEAD END EQUIPMENT AND RECONNECT TO NEW. LOW VOLTAGE

SPEAKER WIRING SHALL BE REUSED.

5. REFER TO THE SITE PLAN SHEET EY100 FOR CONTINUATION OF CONDUIT ROUTING AND SIZE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:4

A

M

EY102

B1 - FIRST FLOOR PLAN - PA

SYSTEM

VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

DRAWING NOTES:

1/16" = 1'-0"

B1 - FIRST FLOOR PLAN - ELECTRICAL EQUIPMENT

N

0 8' 16' 32' 48'

1/16" = 1'-0"

Revisions Date

DN

DN

DN

UP

DN

DN

DIRECTOR'S OFFICE

222A

Assoc Dir Office

OFFICE

OFFICE

STOR.

CONF. RM.

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STOR.

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STAIR#2

OFFICE

STAIR#3

LOUNGE

CORRIDOR

CORR.

STAIR#1

TOILET

TOILET

M. TOILET

LOUNGE

MOP

TOILET

CLOSET

TOILET

CLOSET

234A

TOILET

TOILET

HAC

S

S

S

SS S SS

1. FIELD VERIFY LOCATION OF EXISTING DATA CABLING AND PA SYSTEM EQUIPMENT PRIOR TO

WORK.

2. REFER TO SHEET E-601 FOR BUILDING PA INTERCONNECTION DIAGRAM.

3. NEW PA SOURCE EQUIPMENT SHALL HAVE BUT NOT BE LIMITED TO THE FOLLOWING FEATURES:

A. SELF CONTAINED OR ON BOARD SYSTEM PROGRAM MEMORY SHALL BE NON-VOLATILE AND

PROTECTED FROM ERASURE FROM POWER OUTAGES FOR A MINIMUM OF 24 HOURS.

B. BACKUP BATTERY OR A UPS FOR THE SYSTEM TO ALLOW NORMAL OPERATION AND FUNCTION

IN THE EVENT OF AN AC POWER FAILURE OR DURING INPUT POWER FLUCTUATIONS FOR A

MINIMUM OF TWO (2) HOURS

C. THE PA SHALL PROVIDE ZONED, ONE-WAY VOICE PAGING THROUGH DISTRIBUTED, CEILING

MOUNTED LOUDSPEAKERS. VOICE INPUT INTO THE PA SHALL BE BY ZONE USING THE

TELEPHONE SYSTEM.

D. THE SYSTEM SHALL BE ABLE TO INTERFACE WITH NURSE CALL AND FIRE ALARM.

E. THE SYSTEM SHALL INTERFACE WITH THE FACILITY’S EXISTING DATA NETWORK.

4. ALL SPEAKER DEVICES ON THIS SHEET ARE EXISTING TO REMAIN. SPEAKER LOCATIONS ARE

BASED ON RECORD DRAWINGS AND FIELD OBSERVATION. CONTRACTOR TO ADD 10%

REPLACEMENT CONTINGENCY. FIELD VERIFY EXACT LOCATIONS AND QUANTITIES.

IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES. DISCONNECT ALL SPEAKERS FROM

EXISTING PA SYSTEM HEAD END EQUIPMENT AND RECONNECT TO NEW. LOW VOLTAGE

SPEAKER WIRING SHALL BE REUSED.

5. REFER TO THE SITE PLAN SHEET EY100 FOR CONTINUATION OF CONDUIT ROUTING AND SIZE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:4

A

M

EY103

B1 - SECOND FLOOR PLAN - PA

SYSTEM

VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

DRAWING NOTES:

N

0 8' 16' 32' 48'

1/16" = 1'-0"

1/16" = 1'-0"

B1 - SECOND FLOOR PLAN - ELECTRICAL EQUIPMENT

Revisions Date

G062

GENERAL STORAGE

442 SF

G059

AUTOPSY SUITE

446 SF

GO56

MORGUE RECEIVING

324 SF

G055

TOILET

135 SF

G061

CORRIDOR

288 SF

G070

BULK STOR.

659 SF

G058

UNEXCAVATED

G071

GEN STORAGE

94 SF

G032

TRANSFORMER

491 SF

G079

GAS STOR

117 SF

G080

CHEM.

70 SF

G028

MRI EXAM/SCAN

309 SF

G031

EMERG GEN

51 SF

G009

MECHANICAL ROOM

G010

CLEAN SUPPLY

169 SF

G063

ELEV LOBBY

223 SF

G013

M. SHOWER

182 SF

G014

MALE LOCK.

227 SF

G016

GENERAL STORAGE

672 SF

G017A

MECHANICAL

G017

UNEXCAVATED

G011

F. LOCK. RM

161 SF

G019

UNEXCAVATED

G068

STOR.

96 SF

G0201

ELECTRICAL

G019A

FIRE ALARM EQUIP

22 SF

G

E L E

C C

L

S

F

G012

F. SHOWER

182 SF

G

E L E

C C

L

G060

MECH

39 SF

UNEXCAVATED

G028G

COMP RM

176 SF

G028E

COMPUTER RM

157 SF

G028D

WAITING

164 SF

G028A

VEST

114 SF

G028C

HC TOILET

47 SF

G028B

STORAGE

57 SF

G070A

BULK STOR.

146 SF

G020E

TOILET

50 SF

GO20F

STAFF

112 SF

G020G

OFFICE

90 SF

G020H

CONTROL

224 SF

G020J

MRI EXAM

491 SF

G020

WAITING ROOM

334SF

G020L

MECHANICAL

88 SF

G020M

EQUIP STOR

113 SF

G020 i

EQUIP STORAGE

G020K

GEN STORAGE

100 SF

GO20 D

TLT/DRESS

58 SF

GO20P

SUB WAIT

69 SF

G020A

HOLD

150 SF

G020D

HALL

71 SF

G070

FEC

GO48

CORRIDOR

GO18

CORRIDOR

GO30

CORRIDOR

GO54

CORRIDOR

G003B

SPD STORAGE

G003A

SPD BREAKDOWN

G006

TOILET

G005

PATIENT EFFECTS

G004

LOGISTICS

G005A

VALUABLE

STORAGE

G004A

OFFICE

G004B

OFFICE

G083

STERILE STORAGE

117 SF

G086

BREAKOUT RECEIVING

136 SF

G091B

STORAGE

102 SF

G091A

VESTIBULE

82 SF

G091

SHIPPING AND RECEIVING

186 SF

G085

MALE

123 SF

G084

FEMALE

110 SF

G081

ETO

131 SF

G080

PREP & PACK

-- SF

G074

DECONTAM

-- SF

G045

DISPATCH

-- SF

G045

STORAGE

55 SF

G

A U

T O

C A

R T

W A

S H

S

F

G075

CORRIDOR

-- SF

G076

EQUIP WASH

109 SF

G072

DETERGENT RM

145 SF

G050

LINEN

86 SF

GO40

OFFICE

136 SF

G038

DECONTAM

165 SF

G039

OFFICE

125 SF

G037

CONFERENCE

277 SF

G035

SOILED RECEIVING

179 SF

G049

LOADING DOCK

D N

D N

LOADING DOCK

D N

D N

S

S

S

S S S S S S S SS

S

S

S

S

S

S

S

S

S

S

G017A

MECHANICAL

EY104

ARMORED FIBER OPTIC

CABLING CONTINUATION

FOR BLDGS 1,2,3,4,8,

9,11,12,13,19,20,21 ROUTED

TO BLDG 5

ARMORED FIBER OPTIC

CABLING CONTINUATION FOR

BLDGS 4,8,11, 13,19, 21 ROUTED

TO BLDG 5

FIBER CONTINUATION FOR BLDGS 1,3,9,12,20

ROUTED TO BLDG 5

1. FIELD VERIFY LOCATION OF EXISTING DATA CABLING AND PA SYSTEM EQUIPMENT PRIOR TO

WORK.

2. REFER TO SHEET E-601 FOR BUILDING PA INTERCONNECTION DIAGRAM.

3. NEW PA SOURCE EQUIPMENT SHALL HAVE BUT NOT BE LIMITED TO THE FOLLOWING FEATURES:

A. SELF CONTAINED OR ON BOARD SYSTEM PROGRAM MEMORY SHALL BE NON-VOLATILE AND

PROTECTED FROM ERASURE FROM POWER OUTAGES FOR A MINIMUM OF 24 HOURS.

B. BACKUP BATTERY OR A UPS FOR THE SYSTEM TO ALLOW NORMAL OPERATION AND FUNCTION

IN THE EVENT OF AN AC POWER FAILURE OR DURING INPUT POWER FLUCTUATIONS FOR A

MINIMUM OF TWO (2) HOURS

C. THE PA SHALL PROVIDE ZONED, ONE-WAY VOICE PAGING THROUGH DISTRIBUTED, CEILING

MOUNTED LOUDSPEAKERS. VOICE INPUT INTO THE PA SHALL BE BY ZONE USING THE

TELEPHONE SYSTEM.

D. THE SYSTEM SHALL BE ABLE TO INTERFACE WITH NURSE CALL AND FIRE ALARM.

E. THE SYSTEM SHALL INTERFACE WITH THE FACILITY’S EXISTING DATA NETWORK.

EXISTING CABINET

WITH AMPLIFIER ZONE #2

UPS (BELOW AMPLIFIER

IN MOBILE RACK)

4. ALL SPEAKER DEVICES ON THIS SHEET ARE EXISTING TO REMAIN. SPEAKER LOCATIONS ARE

BASED ON RECORD DRAWINGS AND FIELD OBSERVATION. CONTRACTOR TO ADD 10%

REPLACEMENT CONTINGENCY. FIELD VERIFY EXACT LOCATIONS AND QUANTITIES.

IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES. DISCONNECT ALL SPEAKERS FROM

EXISTING PA SYSTEM HEAD END EQUIPMENT AND RECONNECT TO NEW. LOW VOLTAGE

SPEAKER WIRING SHALL BE REUSED.

5. REFER TO THE SITE PLAN SHEET EY100 FOR CONTINUATION OF CONDUIT ROUTING AND SIZE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:4

A

M

EY104

B2 - BASEMENT PLAN - PA

SYSTEM

VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

N

0 8' 16' 32' 48'

1/16" = 1'-0"

1/16" = 1'-0"

B2 - BASEMENT PLAN - ELECTRICAL EQUIPMENT

CODED NOTES:

DRAWING NOTES:

1 PROVIDE NEW PA HEAD END EQUIPMENT AS SHOWN. REUSE AND REROUTE EXISTING LOW VOLTAGE

WIRING AND CONDUIT TO RECONNECT EXISTING DOWNSTREAM EQUIPMENT TO NEW PA HEAD END

EQUIPMENT. CONNECT SINGLE MODE FIBER OPTIC CABLES FROM PA HEAD END EQUIPMENT TO THE MAIN PA SOURCE EQUIPMENT LOCATION IN BUILDING 5. FIELD VERIFY PA HEAD END EQUIPMENT IS PLUGGED INTO EMERGENCY PLUGS IN RACK. CLEAN AND REUSE EXISTING ROLLING CABINET FOR

NEW EQUIPMENT.

1/4" = 1'-0"2

ENLARGED PLAN BLDG 2 RM G041

0 2' 4' 8' 12'

1/4" = 1'-0"

Revisions Date

1 ADDENDUM #1 12/01/23

6. INSTALL NEW CABLING IN EXPOSED CONDUIT IN CRAWL SPACES, ELECTRICAL AND

MECHANICAL ROOMS AND TUNNELS. ASSUME CABLING WILL BE INSTALLED CONCEALED

ABOVE SUSPENDED ACOUSTIC CEILING IN ALL OTHER SPACES UNLESS OTHERWISE NOTED. 1

FEC

DENTAL LAB

DENTAL O

P #8

STAIRS #4

1147A

DENTAL O

P #7

DENTAL BREAK

FIRE CLS

1141A

DENTAL O

P #5

1149A

DENTAL O

P #6

1149B

DENTAL O

P #4

DENTAL STORAGE

CLEAN S

TOR.

DENTAL O

P#3

DENTAL O

P#2

DENTAL

PHARMACY

EXAM

VAULT

STAIRS

1157A

ELEC. CLS

PHARMACY

ELEC

STORAGE

D U

M B

W A

IT

E

R S

OFFICE

CLINIC

OFFICE

OFFICE

1009B

WAITING AREA

CONF ROOM

STORAGE

LOBBY

RECEPTION

EXAM

EXAM

NURSE

EXAM

1167A

TOILET

EXAM

EXAM

BREAK RM

OFFICE

OFFICE

EXAM

EXAM

1006A

EXAM

1007A

STOR

1010A

ELEC

FEC

OFFICE

STAIRS

T O

IL

E T

CLEAN SUPPLY

OFFICE

OFFICE

STOR.

STOR.

STAIRS

TOILET

ELEC.

M.O.D. OFFICE

IV STORAGE

S T

O R

A G

E

M C

L O

S E

T

OFFICE

OFFICE

OFFICE

OFFICE

1096B

OFFICE

OFFICE

STORAGE

OFFICE

OFFICE

TOILET

TOILET

MED ROOM

LOCKERS

CLEAN LINEN

EXAM

EXAM

EXAM

1083STORAGE23

1084A

TOIL/SHWR

OFFICE

STAIRS

LOUNGE

TOILET

HOLDING

EXAM

EXAM

TOILET

1064STORAGE10

OFFICE

VESTIBULE

1070ELEC.27

OBSERVATION

1081STORAGE23

X X

X X

X X

X X

X

1065CLOSET11

1066UTILITY40

1188A

ELECT.

1190A

TELE

TELE. CLS

1170A

SOILED UTILITY

1009C

OFFICE

STOR.

STOR.

OFFICE

OFFICE

1D147

PROCEDURE

1D147B

MED

1D111

CLEAN

1D112

TOILET

1D113

STORAGE

1D114

CONSULT

1D115

CONSULT

1D116

CONSULT

1D117

EXAM

1D118

EXAM

1D113A

TELE

1D147A

TOILET

1D146

ELEC

1D142

SOILED

1D143

SPD

1D144

CLEAN LINEN

1D150

TOILET

C1-15

CORR

1D151

LOUNGE

C1-14

CORR

1D104

WOMEN

1D105

MEN

C1-11

CORR

1D103

MECH

1D102

HAC

1D101D

TOILET

1D101C

DR. OFFICE

1D131

CONFERENCE

1D130

EXAM

1D129

EXAM

1D128

EXAM

1D127

EXAM

1D126

EXAM

1D125

EXAM

1D124

EXAM

1D123

EXAM

1D122

EXAM

1D121

EXAM

1D120

EXAM

1D145A

STORAGE

1D141

OFFICE

1D140

OFFICE

1D145

H. A. S.

1D110 screening

1D106

WAITING

1D101

PASSAGE

1D101B

A. O.

1D101A

SECRETARY

1D100B

OFFICE

C1-12

VESTIBULE

C1-12

CORR

LINEN

RN ALCOVE

1096D

CLEAN SUPPLY

1096C

WAITING

1096A

OFFICE

961101A

STORAGE

STORAGE

ELEC

1159A

WAITING

1159B

OFFICE

1159C

CORRIDOR

1D100A

OFFICE

1140A

DIR

TY

GEN STORAGE

CLEAN SUPPLY

EXAM

EXAM

EXIT CORR

OFFICE

OFFICE

EXAM

EXAM

OFFICE

CORR

WAITING

HOLDING

POLICE

VESTIBULE

CORR

M TLT

F TLT

AOD

HALLWAY

1050A

ELEC

FAC

HALLWAY

OFFICE

DENTAL O

P #9

DENTAL X-R

AY

FEC

LINEN CHUTE

LINEN CHUTE

1192A

ELECT.

TOILET

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

C1-13

CORR

CORRIDOR

CORRIDOR

GEN STORAGE

LOBBY

RECEPTION

TOILET

LOBBY

M. TOILET

Cafe Shop

Canteen Service

STAIRS

B-1

S

S

S

S

S

S S

S S

S

S

S

S S

S S S S

S

S S

S

S

S

S S

S

S

S

S

S

S

S

S S S S

S S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

WALK WAY TO B20

FIRST FLOOR. SEE

SHEET EY144 FOR

SPEAKER LOCATIONS.

UNDER CONSTRUCTION

1. FIELD VERIFY LOCATION OF EXISTING DATA CABLING AND PA SYSTEM EQUIPMENT PRIOR TO

WORK.

2. REFER TO SHEET E-601 FOR BUILDING PA INTERCONNECTION DIAGRAM.

3. NEW PA SOURCE EQUIPMENT SHALL HAVE BUT NOT BE LIMITED TO THE FOLLOWING FEATURES:

A. SELF CONTAINED OR ON BOARD SYSTEM PROGRAM MEMORY SHALL BE NON-VOLATILE AND

PROTECTED FROM ERASURE FROM POWER OUTAGES FOR A MINIMUM OF 24 HOURS.

B. BACKUP BATTERY OR A UPS FOR THE SYSTEM TO ALLOW NORMAL OPERATION AND FUNCTION

IN THE EVENT OF AN AC POWER FAILURE OR DURING INPUT POWER FLUCTUATIONS FOR A

MINIMUM OF TWO (2) HOURS

C. THE PA SHALL PROVIDE ZONED, ONE-WAY VOICE PAGING THROUGH DISTRIBUTED, CEILING

MOUNTED LOUDSPEAKERS. VOICE INPUT INTO THE PA SHALL BE BY ZONE USING THE

TELEPHONE SYSTEM.

D. THE SYSTEM SHALL BE ABLE TO INTERFACE WITH NURSE CALL AND FIRE ALARM.

E. THE SYSTEM SHALL INTERFACE WITH THE FACILITY’S EXISTING DATA NETWORK.

4. ALL SPEAKER DEVICES ON THIS SHEET ARE EXISTING TO REMAIN. SPEAKER LOCATIONS ARE

BASED ON RECORD DRAWINGS AND FIELD OBSERVATION. CONTRACTOR TO ADD 10%

REPLACEMENT CONTINGENCY. FIELD VERIFY EXACT LOCATIONS AND QUANTITIES.

IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES. DISCONNECT ALL SPEAKERS FROM

EXISTING PA SYSTEM HEAD END EQUIPMENT AND RECONNECT TO NEW. LOW VOLTAGE

SPEAKER WIRING SHALL BE REUSED.

5. REFER TO THE SITE PLAN SHEET EY100 FOR CONTINUATION OF CONDUIT ROUTING AND SIZE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s /0

V

A M

C S a lis b u ry

U p g ra d e P

A S y s te m /0

V A

M C

S a lis b u ry

U p g ra d e

P A

R

E

.r v t

/6 /2

:1

:4

A

M

EY105

B2 - FIRST FLOOR PLAN - PA

SYSTEM

VAMC Salisbury - Upgrade PA System

W.G. (Bill) Hefner VAMC

659-22-201

10/24/2023 JFR KEM

100% CONSTRUCTION

DOCUMENTS SUBMISSION

DRAWING NOTES:

1/16" = 1'-0"

B2 - FIRST FLOOR PLAN - ELECTRICAL EQUIPMENT

N

0 8' 16' 32' 48'

1/16" = 1'-0"

Revisions Date

STAIRS

XRAY

CONTROL RM

DRESSING

XRAY

CONT RM

DRESSING

XRAY

FILM PROCESS

WORK ROOM

CT SCANNER

XRAY

HALLWAY

CT OPER.

CLEAN STOR

2110A

OFFICE

2110B

OFFICE

EXAM

TOILET

2110C

WAITING

NUC MED

NUC MED

CONFERENCE

WAITING ROOM

OFFICE

2098A

OFFICE

2098B

OFFICE

2098C

OFFICE

2098D

OFFICE

2098E

OFFICE

2098F

OFFICE

OFFICE

OFFICE

GEN STOR

TOILET

TOILET

D/W

EXAM

EXAM

EXAM

OFFICE

OFFICE

TLT

STAIRS

WAITING ROOM

TOILET

GEN STOR

TOILET

OFFICE

OFFICE

TLT

OFFICE

OFFICE

TLT

EXAM

FEC

TOILET

EXAM

CLEAN SUP

48 2058

TOILET

OFFICE

HAC

TLT

CLOSET

2059A

TOILET

EXAM

EXAM

OFFICE

LOCK

COMPUTER ROOM

LINEN CHUTE

17 2161

OFFICE

OFFICE

LOCKERS

TOILET

LOCKERS

TLT

ELECT

TOILET

2168A

TEL

STORAGE

TOIL.

TLT

TLT

TLT

OFFICE

HAC

CONT RM

2130A

ELECT

FEC

ELECT.

2098G

BATHROOM

2095A

GEN STOR.

2098H

RECEPT.

FAC

WAITING

2152107A

HOT LAB

2090A

OFFICE

BONE DENS

EXAM

2027A

Corridor

CT SCANNER 2

HAC

CORRIDOR

LAB

LAB

FEMALE ST. TLT

LOCKERS

M A

L E

S T . T

L T2047

ST BREAK AREA

S T W

K S

T N

O F F

IC

E

CHIEF OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

OFFICE

2035A

HALL W

AY

H A

L L W

A Y

HALL WAY

2030A

TECH WKSTN

BLOOD STAGING

SPECIMEN TLT

SPECIMEN TLT2029

WAITING

BLOOD DRAW

BLOOD DRAW

BLOOD DRAW

TELE

STORAGE

2133A

ELE CLST

CORRIDOR

ELEC

CORRIDOR

CORRIDOR

FEC

STAIRS

STAIRS

LINEN CHUTE

2161A

OFFICE

ECHO

READING

TREADMILL 1

TREADMILL 2

STORAGE

NURSE

WORK

EXISTING

TOIL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .