AHU List.pdf
PDF 16 MB Posted
- Attached to
- J041--HVAC Duct Cleaning Building 500
- Solicitation number
- 36C24623Q0962
About this file
This document provides details on a federal contract opportunity for HVAC duct cleaning services. The solicitation number is 36C24623Q0962 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 for duct cleaning services at Building 500. The related file is an 16MB PDF titled AHU List that contains additional specifications. The opportunity type is listed as a solicitation and responses are due based on the standard FAR solicitation timeline. Pricing terms and any set aside designations are not included in this overview of the opportunity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24623Q0962 0003.docx | DOCX document | |
| 36C24623Q0962 0002.docx | DOCX document | |
| Richmond VAMC HVAC Duct Cleaning Questions Part 2.docx | DOCX document | |
| 36C24623Q0962 0001.docx | DOCX document | |
| Richmond VAMC HVAC Duct Cleaning Questions 1.pdf | ||
| 36C24623Q0962_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SAFETY DATA SHEET
Revision Date 14-May-2018 Version 2.01
1. Identification of the substance/mixture and of the company/undertaking
1.1 Product identifier
Product name Product code
Mediclean Disinfectant Spray Plus Fragrance Free LG-F1088
1.2 Relevant identified uses of the substance or mixture and uses advised against
Recommended Use Registered Disinfectant Restrictions on use Professional Use Only EPA Registration Number 70385-5
Other information This SDS is reviewed as an US EPA registered product.
1.3 Details of the supplier of the safety data sheet
Supplier Legend Brands ProRestore Products 15180 Josh Wilson Road Burlington, WA 98233 800-932-3030
1.4 Emergency telephone number
Emergency telephone number INFOTRAC 1-800-535-5053 (North America) 1-352-323-3500 (International)
2. Hazards identification
2.1 Classification of the substance or mixture
GHS Classification in accordance with 29 CFR 1910.1200
OSHA Regulatory Status This product is regulated by EPA- not subject to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200).
2.2 Label elements
Signal Word Warning
Hazard Statements
Flammable liquid and vapor
Flammable liquids Category 3
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 1 / 9
LG-F1088 - Mediclean Disinfectant Spray Plus Fragrance Free Revision Date 14-May-2018
Precautionary Statements - Prevention Keep away from heat/sparks/open flames/hot surfaces. - No smoking Keep container tightly closed Ground/Bond container and receiving equipment Use explosion-proof electrical/ventilating/lighting/equipment Use only non-sparking tools Take precautionary measures against static discharge Wear protective gloves/clothing and eye/face protection
Precautionary Statements - Response
IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower In case of fire: Use CO2, dry chemical, or foam to extinguish
Precautionary Statements - Storage Store in a well-ventilated place. Keep cool
Precautionary Statements - Disposal Dispose of contents/container to an approved waste disposal plant
2.3. Other Hazards Hazards not otherwise classified (HNOC)
Not Applicable
2.4 Other information
Not Applicable
Unknown Acute Toxicity < 1% of the mixture consists of ingredient(s) of unknown toxicity
3. Composition/Information on Ingredients Substance Mixture
The exact percentage (concentration) of composition has been withheld as a trade secret.
4. First aid measures
4.1 Description of first-aid measures
General advice Show this safety data sheet to the doctor in attendance. When symptoms persist or in all cases of doubt seek medical advice.
Eye contact Remove contact lenses, if present. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Call a physician if irritation develops or persists.
Skin contact Wash off immediately with soap and plenty of water. Remove all contaminated clothes and shoes. Use a mild soap if available. Call a physician if irritation develops or persists.
Inhalation Move to fresh air. If not breathing, give artificial respiration. Consult a physician after significant exposure.
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 2 / 9
Chemical Name CAS No. Weight-% Isopropyl alcohol 67-63-0 5 - 10
Ingestion Gently wipe or rinse the inside of the mouth with water. Give small amounts of water to drink. Never give anything by mouth to an unconscious person. Do NOT induce vomiting.
Get medical attention immediately.
4.2 Most important symptoms and effects, both acute and delayed
Symptoms See Section 2.2, Label Elements and/or Section 11, Toxicological effects.
4.3 Indication of any immediate medical attention and special treatment needed
Notes to physician Treat symptomatically.
5. Fire-Fighting Measures
5.1 Extinguishing media
Suitable extinguishing media Use water spray, fog, Carbon dioxide (CO 2), foam or dry chemical.
Unsuitable Extinguishing Media High volume water jet.
5.2 Special hazards arising from the substance or mixture
Special Hazard Hazardous decomposition products formed under fire conditions. Flash back possible over considerable distance. Immediately place absorbent material in a sealed water-filled metal container to avoid spontaneous combustion of absorbent material contaminated with this product.
Hazardous Combustion Products No information available.
Explosion Data Sensitivity to Mechanical Impact None.
Sensitivity to Static Discharge None.
5.3 Advice for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
6. Accidental Release Measures
6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Remove all sources of ignition. Ensure adequate ventilation, especially in confined areas.
Avoid contact with skin, eyes and clothing. Do not breathe vapors or spray mist.
6.2 Environmental precautions
Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. Do not allow material to contaminate ground water system. See Section 12 for additional Ecological information.
6.3 Methods and materials for containment and cleaning up
Methods for Containment Prevent further leakage or spillage if safe to do so.
Methods for cleaning up Pick up and transfer to properly labeled containers.
7. Handling and storage
7.1 Precautions for safe handling
Advice on safe handling Wear personal protective equipment. Avoid contact with skin, eyes and clothing. Do not
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 3 / 9
LG-F1088 - Mediclean Disinfectant Spray Plus Fragrance Free Revision Date 14-May-2018 breathe vapors or spray mist. Vapors may form explosive mixtures with air. Prevent the creation of flammable or explosive concentrations of vapor in air and avoid vapor concentration higher than the occupational exposure limits. Mixture may charge electrostatically: always use earthing leads when transferring from one container to another.
Keep away from sources of ignition - No smoking. Use only in area provided with appropriate exhaust ventilation. Use only explosion-proof equipment. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded.
Electrical equipment should be protected to the appropriate standard.
Hygiene measures When using, do not eat, drink or smoke. Wash hands before breaks and at the end of workday. Remove and wash contaminated clothing before re-use.
7.2 Conditions for safe storage, including any incompatibilities
Storage Conditions Keep locked up or in an area accessible only to qualified or authorized persons. Store between 41 and 77 °F (5 - 25° C) in a dry, well ventilated place away from sources of heat, ignition and direct sunlight. Store in original container.
Materials to Avoid Strong oxidizing agents.
8. Exposure controls/personal protection
8.1 Exposure Guidelines
8.2 Appropriate engineering controls
Engineering Measures Ensure adequate ventilation, especially in confined areas.
8.3 Individual protection measures, such as personal protective equipment
Eye/Face Protection Safety glasses with side-shields.
Skin and body protection Long sleeved clothing. Rubber or plastic apron.
Respiratory protection Respirator with filter for organic vapor. If these are not sufficient to maintain concentrations of particulates and solvent vapor below the OEL, suitable respiratory protection must be worn.
Hygiene measures See section 7 for more information
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 4 / 9
10. Stability and Reactivity
9. Physical and chemical properties
9.1 Information on basic physical and chemical properties
Physical state Liquid
9.2 Other information
Volatile organic compounds (VOC) content
56.6 g/L
Appearance milky Color transparent
Odor Odorless Odor Threshold No information available
Property Values Remarks • Methods pH 6.5-7.5 Melting/freezing point No information available Boiling point/boiling range 100 °C / 212 °F Flash Point 39 °C / 102 °F Evaporation rate No information available Flammability (solid, gas) No information available Flammability Limits in Air upper flammability limit No information available lower flammability limit No information available
Vapor pressure No information available Vapor density No information available Specific Gravity 0.97 Water solubility Soluble in water Solubility in other solvents No information available Partition coefficient No information available Autoignition temperature No information available Decomposition temperature No information available Viscosity, kinematic No information available Viscosity, dynamic No information available
Explosive properties No information available Oxidizing Properties No information available
10.1 Reactivity
No data available
10.2 Chemical stability
Stable under recommended storage conditions Risk of ignition
10.3 Possibility of hazardous reactions
None under normal processing.
10.4 Conditions to Avoid
Direct sources of heat.
10.5 Incompatible Materials
Strong oxidizing agents.
10.6 Hazardous Decomposition Products
Carbon dioxide (CO2), carbon monoxide (CO), oxides of nitrogen (NOx), dense black smoke.
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 5 / 9
11. Toxicological information
11.1 Acute toxicity
Numerical measures of toxicity: Product Information
The following values are calculated based on chapter 3.1 of the GHS document
Unknown Acute Toxicity < 1% of the mixture consists of ingredient(s) of unknown toxicity
Oral LD50 49,429.00 mg/kg Dermal LD50 49,429.00 mg/kg
Numerical measures of toxicity: Component Information
11.2 Information on toxicological effects
Skin corrosion/irritation Product Information
• No information available Component Information
• No information available
Serious eye damage/eye irritation Product Information
• No information available Component Information
• No information available
Respiratory or skin sensitization Product Information
• No information available Component Information
• No information available
Germ cell mutagenicity Product Information
• No information available Component Information
• No information available
Carcinogenicity Product Information
• The table below indicates whether each agency has listed any ingredient as a carcinogen Component Information
• Contains a known or suspected carcinogen
Reproductive toxicity Product Information
• No information available Component Information
• No information available
STOT - single exposure No information available
STOT - repeated exposure
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 6 / 9
No information available
Other adverse effects Product Information
• No information available Component Information
• No information available
Aspiration hazard Product Information
• No information available Component Information
• No information available
12. Ecological information
12.1 Toxicity
Ecotoxicity No information available
1.45396 % of the mixture consists of components(s) of unknown hazards to the aquatic environment
Ecotoxicity effects
12.2 Persistence and degradability
No information available.
12.3 Bioaccumulative potential
Discharge into the environment must be avoided
12.4 Mobility in soil
No information available.
12.5 Other adverse effects
Discharge into the environment must be avoided
13. Disposal Considerations
13.1 Waste treatment methods
This material, as supplied, is not a hazardous waste according to Federal regulations (40 CFR 261). This material could become a hazardous waste if it is mixed with or otherwise comes in contact with a hazardous waste, if chemical additions are made to this material, or if the material is processed or otherwise altered. Consult 40 CFR 261 to determine whether the altered material is a hazardous waste. Consult the appropriate state, regional, or local regulations for additional requirements.
14. Transport Information
DOT Not regulated (If shipped in NON BULK packaging by ground transport)
MEX -
IMDG
Proper shipping name FLAMMABLE LIQUID, N.O.S. (ISOPROPANOL) Hazard class 3
UN 1993
Packing Group III
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 7 / 9
IATA Air transport is not recommended.
15. Regulatory information
15.1 International Inventories
TSCA Complies DSL Complies EINECS/ELINCS Complies ENCS Complies IECSC Complies KECL Complies PICCS Complies AICS Complies NZIoC Complies
TSCA - United States Toxic Substances Control Act Section 8(b) Inventory DSL - Canadian Domestic Substances List EINECS/ELINCS - European Inventory of Existing Chemical Substances/European List of Notified Chemical Substances PICCS - Philippines Inventory of Chemicals and Chemical Substances ENCS - Japan Existing and New Chemical Substances IECSC - China Inventory of Existing Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances PICCS - Philippines Inventory of Chemicals and Chemical Substances AICS - Australian Inventory of Chemical Substances NZIoC - New Zealand Inventory of Chemicals
15.2 U.S. Federal Regulations
SARA 313
Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product contains a chemical or chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372:
Chemical Name SARA 313 - Threshold Values % Isopropyl alcohol
67-63-0-LB
1.0
15.3 Pesticide Information
Not applicable U.S. EPA Pesticide Information
15.4 U.S. State Regulations
16. Other information
EPA Pesticide Registration Number 70385-5 EPA Statement This chemical is a pesticide product registered by the Environmental Protection Agency and is subject to certain labeling requirements under federal pesticide law. These requirements differ from the classification criteria and hazard information required for safety data sheets, and for workplace labels of non-pesticide chemicals. Following is the hazard information as required on the pesticide label:
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 8 / 9
EPA Pesticide Label WARNING - Harmful if swallowed (inhaled or absorbed through the skin). Do not breathe vapors (dust or spray mist). Do not get in eyes, on skin or on clothing. Causes eye (and skin) irritation.
California Proposition 65 Not applicable - This product is not for sale in California.
Legend:
ACGIH (American Conference of Governmental Industrial Hygienists) Ceiling (C) DOT (Department of Transportation) EPA (Environmental Protection Agency) IARC (International Agency for Research on Cancer) International Air Transport Association (IATA) International Maritime Dangerous Goods (IMDG) NIOSH (National Institute for Occupational Safety and Health) NTP (National Toxicology Program) OSHA (Occupational Safety and Health Administration of the US Department of Labor) PEL (Permissible Exposure Limit) Reportable Quantity (RQ) Skin designation (S*) STEL (Short Term Exposure Limit) TLV® (Threshold Limit Value) TWA (time-weighted average)
Revision Date 14-May-2018 Revision Note No information available Disclaimer The information provided on this SDS is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
End of Safety Data Sheet
NFPA Health Hazard 0 Flammability 2 Instability 0 Physical and chemical hazards -
HMIS Health Hazard 0 Flammability 2 Physical Hazard 0 Personal protection X
14-May-2018 - LG-F1088 - 2.01 - AGHS - English - Page 9 / 9
MILDEWCIDE • BACTERICIDE • FUNGICIDE
DEODORANT AND DISINFECTANT (Anti-Microbial)
FOR HOUSEHOLD, FARM PREMISE USES AND ANIMAL QUARTERS
Mediclean Disinfectant Spray Plus is a Broad Spectrum Disinfectant and is Also Effective Against Fungi, Mold & Mildew, and Odors Caused by Bacteria
KEEP OUT OF REACH OF CHILDREN
WARNING
ACTIVE INGREDIENTS
o-Phenylphenol ________________________________________ 0.22% Diisobutylphenoxyethoxy ethyl dimethyl benzyl ammonium chloride monohydrate______________ 0.70%
INERT INGREDIENTS ______________________________________ 99.08%
TOTAL ______________________________________________ 100.00%
NOT REGISTERED FOR SALE/USE IN CALIFORNIA
Manufactured For: PRORESTORE® PRODUCTS
15180 Josh Wilson Road, Burlington, WA 98233 U.S. Patent No. 3,458,629
TE
ST
F
AB
RI
C
OR
S
UR
FA
CE
IN
A N
IN
CO
NS
PI
CU
OU
S
AR
EA
FO
R
CO
LO
R
FA
ST
NE
SS
O
R
AD
VE
RS
E
RE
AC
TI
ON
PRECAUTIONARY STATEMENTS:
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
WARNING: Harmful if swallowed (inhaled or absorbed through the skin). Do not breathe vapors (dust or spray mist). Do not get in eyes, on skin, or on clothing. Causes eye (and skin) irritation.
FOR AIR DUCT USAGE:
DIRECTIONS FOR USE
It is a violation of Federal Law to use this product in a manner inconsistent with its labeling.
Mediclean® Disinfectant Spray Plus should be applied with hand or power operated sprayers, foggers, automated metering systems or gravity drip dispensers as a broad spectrum disinfectant, mold and mildewcide, fungicide and deodorizing agent to previously cleaned sur-faces. Spray areas until thoroughly moist, giving special attention to cracks and crevices. Allow ten to twenty minutes for drying. It is not necessary to wipe the sprayed surface. Mediclean Disinfectant Spray Plus should not stain those materials not stained by water. Mediclean Disinfectant Spray Plus, when used as directed, is effective in decontaminating bedding, mattresses, textiles, drapes, upholstered furniture, rugs, carpets and in storage areas to control mold, mildew, fungus and odors wherever they are a problem.
GENERAL METHOD OF APPLICATION
Surfaces and objects must be cleaned of gross filth with suitable detergent before treatment. Spray surfaces and articles until thoroughly wet, use enough so that treated surfaces and objects remain wet for at least 10 minutes. May be applied with a sponge to impervious covers and surfaces, allowing to dry for 10 minutes. For fogging and other large volume applications use appropriate spraying equipment, protective clothing, gloves and respirator. Heavily treated spaces should be adequately ventilated and not re-entered for at least one hour after treatment.
AS A MILDEWCIDE, FUNGICIDE, BROAD SPECTRUM DISINFECTANT AND VIRUCIDE*: (Kills the influenza virus). In lobbies, hallways, washrooms, mop rooms, and veterinary clinics; in schools, hotels, motels, restaurants, offices, homes and industrial buildings.
For use on pre-cleaned hard non-porous surfaces such as tiled porcelain, waste receptacles, compactors, on, in and around rest room fixtures, toilet seats, locker rooms, telephones, door knobs, furniture and empty containerized storage units. For athletes foot fungus on floors, shower stalls, rest rooms. Follow method of application specified above.
AS A BACTERIOSTAT, FUNGISTAT AND DEODORIZING AGENT
Apply Mediclean Disinfectant Spray Plus as directed to floors, walls, ceilings that have been damaged by smoke, fire, floods and sewage backups. For cleanup operation in areas such as attics, wall voids, basements, areas above suspended ceilings and similar inaccessible spaces in buildings. Spray avian, rodent and other animal and human wastes and carcasses as directed above, prior to removal and disposal.
Treat spaces and surfaces as specified in method of application. For use as a bacteriostat, fungistat and deodorizing agent on carpeting found in schools, hotels, motels, homes, shelters and commercial, industrial and public buildings. After a flood or water damage, vacuum or extract as much water as possible before application. Apply full strength with sprayer until moist to carpet nap and rake or brush in. To treat the backing and padding, a fogger is recommended. Allow to remain until dry. For best results carpets should be cleaned before application.
TO DISINFECT FARM PREMISES, POULTRY
HOUSES, ANIMAL PENS AND VEHICLES
Remove all animals and feed from premises, vehicles and enclosures. Remove all litter and manure from floors, walls and surfaces of barns, pens, stalls, chutes and other facilities and fixtures occupied or traversed by animals. Empty all troughs, racks and other feeding and watering appliances. Thoroughly clean all surfaces with soap or detergent and rinse with water. Saturate all surfaces with the recommended disinfecting solution for a period of ten minutes. Immerse all halters, ropes and other types of equipment used in handling and restraining animals, as well as forks, shovels and scrapers used for removing litter and manure. Ventilate buildings, cars, boats and other closed spaces. Do not house live stock or employ equipment until treatment has been absorbed, set or dried. Thoroughly scrub all treated feed racks, mangers, troughs, automatic feeders, fountains and waterers with soap or detergent and rinse with potable water before reuse. Apply Mediclean Disinfectant Spray Plus full strength as directed in the general method of application until thoroughly wet. Allow all surfaces to dry thoroughly, ventilate enclosed spaces adequately. Do not house animals in treated areas until thoroughly dry and free from odors.
STORAGE AND DISPOSAL
Storage: Keep from freezing. Store in ventilated areas. Do not contaminate water, food or feed by storage and disposal. Dispose leftovers in landfill approved for pesticides.
Pesticide Disposal: Wastes resulting from the use of this product may be disposed of on site or at an approved waste disposal facility.
Container Disposal: Nonrefillable container. Do not reuse or refill this container. Triple rinse (or equivalent). Then offer for recycling, if available or puncture and dispose of in a sanitary landfill, or incineration, or, if allowed by state and local authorities, by burning. If burned, stay out of smoke.
FIRST AID:
IF INHALED: Move person to fresh air. If person is not breathing, call 911 or an ambulance, then give artificial respiration, preferably by mouth-to-mouth, if possible. Call a Poison Control Center or doctor for further treatment advice. IF SWALLOWED: Call a Poison Control Center or doctor immediately for treatment advice. Have person sip a glass of water if able to swallow. Do not induce vomiting unless told to do so by a poison control center or doctor. Do not give anything by mouth to an unconscious person. IF IN EYES: Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if present, after the first 5 minutes, then continue rinsing. Call a poison control center or doctor for treatment advice. IF ON SKIN OR CLOTHING: Take off contaminated clothing. Rinse skin immediately with plenty of water for 15-20 minutes. Call a poison control center or doctor for treatment advice.Have the product container or label with you when calling a Poison Control Center or doctor or going for treatment.
FRAGRANCE FREE
PERSONAL PROTECTION EQUIPMENT REQUIREMENTS FOR HANDLERS: All handlers must wear protective eyewear, long pants, long-sleeved shirts and chemical resistant gloves.
SPECIAL INSTRUCTIONS FOR APPLICATORS: Applicators treating the inside of an air duct system with this product must wear chemical resistant coveralls, chemical resistant gloves, and chemical resistant goggles. In addition, the ductwork must be ventilated with an airflow of approximately 50 CFM per square foot of duct cross section.
If this is not possible, OSHA confined space regulations must be followed and the requirements for a permit required space apply. These requirements include testing the atmosphere and use of adequate respirator protection. If the level of contamination cannot be determined, then maximum respiratory protection (SCBA or airline with an escape bottle) must be used. If needed, the full-face respirator should also be equipped with a spray mist pre-filter in addition to the charcoal filters.
ENGINEERING CONTROLS: During ULV, mist or spray application, the duct system interior must be maintained under slight negative pressure (0.015 to 0.025 In. WG) with an outdoor exhaust or using a negative air machine equipped with HEPA filter. Avoid higher pressure differentials that would be likely to disrupt the coverage pattern.
• Pest Control Service
• Movie booths
• Odor Control Service
• Antique shops
• Refuse trucks
• Restoration Service
• Exercise rooms
• Air Ducts
• Shoes & Boots
• Veterinaries
• Disinfection Service
• Waste Removal Service
• Upholsterers Shops
• Bowling alleys
• Carpet Cleaning Service
• Water Damage Service
• Second hand furniture shops
• Trash Chutes and Garbage Rooms
• Waste Compactors
• Storage areas and Basements
• Condensation collection & Drainage areas
• Laundry receiving stations
See other precautions on side panel
DIRECTIONS FOR USE ON AIR DUCTS ARE CONTAINED IN THE ATTACHED BOOKLET AND MUST
BE READ COMPLETELY PRIOR TO USING THIS PRODUCT. IF THE BOOKLET IS MISSING, RETURN
THIS PRODUCT TO THE PLACE OF PURCHASE AND OBTAIN A REPLACEMENT PACKAGE
© 2019 PRORESTORE® PRODUCTS L.13176 REV (B)
Net Contents:
1 GAL. (3.785) Litres
E.P.A. Reg. No. 70385-5 E.P.A. Est. No. 37615-AZ-1 mediclean®
FRAGRANCE FREE
MILDEWCIDE • BACTERICIDE • FUNGICIDE
DEODORANT AND DISINFECTANT (Anti-Microbial) For Household Use, Farm Premise Uses and Animal Quarters
MediClean Disinfectant Spray Plus is a Broad Spectrum Disinfectant and is Also Effective Against Fungi, Mold & Mildew, and Odors Caused by Bacteria
ACTIVE INGREDIENTS
o-Phenylphenol ________________________________________ 0.22% Diisobutylphenoxyethoxy ethyl dimethyl benzyl ammonium chloride monohydrate______________ 0.70%
INERT INGREDIENTS ______________________________________ 99.08%
TOTAL ______________________________________________ 100.00%
KEEP OUT OF REACH OF CHILDREN
WARNING
FIRST AID: IF INHALED: Move person to fresh air. If person is not breathing, call 911 or an ambulance, then give artificial respiration, preferably by mouth-to-mouth, if possible. Call a Poison Control Center or doctor for further treatment advice. IF SWALLOWED: Call a Poison Control Center or doctor immediately for treatment advice. Have person sip a glass of water if able to swallow. Do not induce vomiting unless told to do so by a poison control center or doctor. Do not give anything by mouth to an unconscious person. IF IN EYES: Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if present, after the first 5 minutes, then continue rinsing. Call a poison control center or doctor for treatment advice. IF ON SKIN OR CLOTHING: Take off contaminated clothing. Rinse skin immediately with plenty of water for 15-20 minutes. Call a poison control center or doctor for treatment advice. Have the product container or label with you when calling a Poison
Control Center or doctor or going for treatment.
PRECAUTIONARY STATEMENTS: HAZARDS TO HUMANS AND DOMESTIC ANIMALS
WARNING: Harmful if swallowed (inhaled or absorbed through the skin). Do not breathe vapors (dust or spray mist). Do not get in eyes, on skin, or on clothing. Causes eye (and skin) irritation.
FOR AIR DUCT USAGE:
PERSONAL PROTECTION EQUIPMENT REQUIREMENTS FOR HANDLERS: All handlers must wear protective eyewear, long pants, long-sleeved shirts and chemical resistant gloves.
SPECIAL INSTRUCTIONS FOR APPLICATORS: Applicators treating the inside of an air duct system with this product must wear chemical resistant coveralls, chemical resistant gloves, and chemical resistant goggles. In addition, the ductwork must be ventilated with an airflow of approximately 50 CFM per square foot of duct cross section. If this is not possible, OSHA confined space regulations must be followed and the requirements for a permit required space apply.
These requirements include testing the atmosphere and use of adequate respirator protection. If the level of contamination cannot be determined, then maximum respiratory protection (SCBA or airline with an escape bottle) must be used.
If needed, the full-face respirator should also be equipped with a spray mist pre-filter in addition to the charcoal filters.
ENGINEERING CONTROLS: During ULV, mist or spray application, the duct system interior must be maintained under slight negative pressure (0.015 to 0.025 In. WG) with an outdoor exhaust or using a negative air machine equipped with HEPA filter. Avoid higher pressure differentials that would be likely to disrupt the coverage pattern.
STORAGE AND DISPOSAL
Storage: Keep from freezing. Store in ventilated areas. Do not contaminate water, food or feed by storage and disposal. Dispose leftovers in landfill approved for pesticides.
Pesticide Disposal: Wastes resulting from the use of this product may be disposed of on site or at an approved waste disposal facility.
Container Disposal: Nonrefillable container. Do not reuse or refill this container. Triple rinse (or equivalent). Then offer for recycling, if available or puncture and dispose of in a sanitary landfill, or incineration, or, if allowed by state and local authorities, by burning. If burned, stay out of smoke.
GENERAL METHOD OF APPLICATION
Surfaces and objects must be cleaned of gross filth with suitable detergent before treatment. Spray surfaces and articles until thoroughly wet, use enough so that treated surfaces and objects remain wet for at least 10 minutes. May be applied with a sponge to impervious covers and surfaces, allowing to dry for 10 minutes. For fogging and other large volume applications use appropriate spraying equipment, protective clothing, gloves and respirator. Heavily treated spaces should be adequately ventilated and not re-entered for at least one hour after treatment.
AS A MILDEWCIDE, FUNGICIDE, BROAD SPECTRUM DISINFECTANT AND VIRUCIDE*: (Kills the influenza virus). In lobbies, hallways, washrooms, mop rooms, and veterinary clinics; in schools, hotels, motels, restaurants, offices, homes and industrial buildings.
For use on pre-cleaned hard non-porous surfaces such as tiled porcelain, waste receptacles, compactors, on, in and around rest room fixtures, toilet seats, locker rooms, telephones, door knobs, furniture and empty containerized storage units. For athletes foot fungus on floors, shower stalls, rest rooms. Follow method of application specified above.
AS A BACTERIOSTAT, FUNGISTAT AND DEODORIZING AGENT
Apply MediClean Disinfectant Spray Plus as directed to floors, walls, ceilings that have been damaged by smoke, fire, floods and sewage backups. For cleanup operation in areas such as attics, wall voids, basements, areas above suspended ceilings and similar inaccessible spaces in buildings. Spray avian, rodent and other animal and human wastes and carcasses as directed above, prior to removal and disposal.
Treat spaces and surfaces as specified in method of application. For use as a bacteriostat, fungistat and deodorizing agent on carpeting found in schools, hotels, motels, homes, shelters and commercial, industrial and public buildings. After a flood or water damage, vacuum or extract as much water as possible before application. Apply full strength with sprayer until moist to carpet nap and rake or brush in. To treat the backing and padding, a fogger is recommended. Allow to remain until dry. For best results carpets should be cleaned before application.
TO DISINFECT FARM PREMISES, POULTRY HOUSES, ANIMAL PENS AND VEHICLES
Remove all animals and feed from premises, vehicles and enclosures. Remove all litter and manure from floors, walls and surfaces of barns, pens, stalls, chutes and other facilities and fixtures occupied or traversed by animals. Empty all troughs, racks and other feeding and watering appliances. Thoroughly clean all surfaces with soap or detergent and rinse with water. Saturate all surfaces with the recommended disinfecting solution for a period of ten minutes. Immerse all halters, ropes and other types of equipment used in handling and restraining animals, as well as forks, shovels and scrapers used for removing litter and manure. Ventilate buildings, cars, boats and other closed spaces. Do not house live stock or employ equipment until treatment has been absorbed, set or dried. Thoroughly scrub all treated feed racks, mangers, troughs, automatic feeders, fountains and waterers with soap or detergent and rinse with potable water before reuse. Apply MediClean Disinfectant Spray Plus full strength as directed in the general method of application until thoroughly wet. Allow all surfaces to dry thoroughly, ventilate enclosed spaces adequately. Do not house animals in treated areas until thoroughly dry and free from odors.
DIRECTIONS FOR USE
It is a violation of Federal Law to use this product in a manner inconsistent with its labeling.
MediClean Disinfectant Spray Plus should be applied with hand or power operated sprayers, foggers, automated metering systems or gravity drip dispensers as a broad spectrum disinfectant, mold and mildewcide, fungicide and deodorizing agent to previously cleaned surfaces. Spray areas until thoroughly moist, giving special attention to cracks and crevices. Allow ten to twenty minutes for drying. It is not necessary to wipe the sprayed surface. MediClean Disinfectant Spray Plus should not stain those materials not stained by water. MediClean Disinfectant Spray Plus, when used as directed, is effective in decontaminating bedding, mattresses, textiles, drapes, upholstered furniture, rugs, carpets and in storage areas to control mold, mildew, fungus and odors wherever they are a problem.
See other precautions below.
NOT REGISTERED FOR SALE/USE IN CALIFORNIA
Manufactured For: PRORESTORE® PRODUCTS 15180 Josh Wilson Road, Burlington, WA 98233 • U.S. Patent No. 3,458,629 TEST FABRIC OR SURFACE IN AN INCONSPICUOUS AREA FOR COLOR FASTNESS OR ADVERSE REACTION
E.P.A. EST. No.
37615-MD-001
37615-AZ-1
E.P.A. Reg. No. 70385-5
PRORESTORE® PRODUCTS
1-800-932-3030
• Pest Control Service
• Movie booths
• Odor Control Service
• Antique shops
• Refuse trucks
• Restoration Service
• Exercise rooms
• Air Ducts
• Shoes & Boots
• Veterinaries
• Disinfection Service
• Waste Removal Service
• Upholsterers Shops
• Bowling alleys
• Carpet Cleaning Service
• Water Damage Service
• Second hand furniture shops
• Trash Chutes and Garbage Rooms
• Waste Compactors
• Storage areas and Basements
• Condensation collection & Drainage areas
• Laundry receiving stations
USE DIRECTIONS FOR AIR DUCTS: IT IS A VIOLATION OF FEDERAL LAW TO USE THIS PRODUCT IN A MANNER INCONSISTENT WITH ITS LABELING THE PERSON APPLYING THIS PRODUCT IS RESPONSIBLE FOR FOLLOWING THESE DIRECTIONS UNDER BOTH STATE AND FEDERAL LAWS.
1.0 General. MEDICLEAN DISINFECTANT SPRAY PLUS is designed to be used as one component of a comprehensive HVAC and duct maintenance program. The purpose of such a program is to assure that the HVAC system and ducts function in the manner they were designed to, remain free from mold and other microbial growth and other contamination, and continue in that condition. This product must only be used in only those cases where visible microbial growth has been detected in the system and then only after removing that growth and identifying and correcting the conditions that led to that growth. If you need help in understanding any part of these instructions or have additional questions after reading these instructions, DO NOT APPLY THISPRODUCT until you have received the answers for all of your questions.
2.0 Inspection. Prior to inspecting, cleaning, treating, repairing or otherwise working on a duct section, the HVAC system should be turned off or the section under repair physically isolated from sections in active use. Prior to any application of MEDICLEAN DISINFECTANT SPRAY PLUS the system must be inspected for cleanliness and mechanical condition. When initiating any measures to repair, clean or treat ducts and associated HVAC system components, industry standards from the National Air Duct Cleaners Association (NADCA) and other organizations must be followed.
HVAC systems should be routinely inspected for cleanliness by visual means. The NADCA Standard, Assessment, Cleaning and Restoration of HVAC Systems (ACR 2002 or the latest revision), provides minimum recommended inspection frequency schedules for ducts and other system components. More information on NADCA standards can be obtained from the NADCA web site at www.nadca.com.
2.1 Cleanliness Inspection. According to NADCA Standards, HVAC system cleaning must be performed when any of the following conditions are found in the cleanliness inspection. If any of these deficiencies are found during inspection, cleaning in accordance with industry standards must be performed prior to the application of MEDICLEAN DISINFECTANT SPRAY PLUS.
2.1.1 Contamination.
• HVAC systems should be operated in a clean condition. If significant accumulations of contaminants or debris are visually observed within the HVAC system, then cleaning is necessary. Likewise, if evidence of microbial growth is visually observed or confirmed by analytical methods, then cleaning is required.
• If the HVAC system discharges visible particulate into the occupied space, or a significant contribution of airborne particles from the HVAC system into the indoor ambient air is confirmed, then cleaning is necessary.
Continued on other side. © 2018 PRORESTORE® PRODUCTS P.2089 REV (D)
• Heat exchange coils, cooling coils, air flow control devices, filtration devices, and air-handling equipment determined to have restrictions, blockages, or contamination deposits that may cause system performance inefficiencies, air flow degradation, or that may significantly affect the design intent of the HVAC system, require cleaning.
• Drain pans must be free from slime and sludge or other contamination. Badly rusted or corroded drain pans must either be repaired or replaced.
• Fans and fan housings must be free from accumulations of microbial growth and particulate matter.
If you need help in understanding existing industry standards, consult a qualified professional or contact ProRestore® Products at 800-332-6037 for guidance and further direction or consult the information at www.epa.gov (search on “air ducts”). In addition, the following association and society Internet sites should be consulted for information on standards and guidelines they have developed:
ACCA – www.acca.org ASHRAE – www.ashrae.org NADCA – www.nadca.com NAIMA – www.naima.org SMACNA – www.smacna.org
2.2 Mechanical Inspection. MEDICLEAN DISINFECTANT SPRAY PLUS must be used only on ducts and other HVAC system components in sound mechanical condition as defined in 2.2.1 and 2.2.2 (below). The HVAC system components must be designed and installed in conformance with industry standards and guidelines. Prior to using the product, inspect the ducts and assure that they are in sound mechanical condition. The following general guidelines, supplemented by industry standards from SMACNA, NAIMA ASHRAE, ACCA and other organizations, must be followed:
2.2.1 Air Leaks and Mechanical Defects. The ducts must be free from air leaks and other mechanical defects. Air leaks will promote condensation of water that causes microbial growth and will lead to failure of MEDICLEAN DISINFECTANT SPRAY PLUS to protect he system adequately.
2.2.2 Design and Installation. ASHRAE, SMACNA, NAIMA and other industry organizations have established guidelines and standards for the design and installation of HVAC and duct systems. You should determine that the duct system you wish to treat conforms to industry practice. If you are not knowledgeable of industry guidelines and standards, consult a qualified professional or contact ProRestore® Products at 800-332-6037 for assistance.
In some situations, the inspection may reveal that the duct system or other component is badly damaged or in such poor operating condition that it cannot be corrected through cleaning and/or minor repair. In these situations, the system should be replaced or rebuilt in conformity to the applicable industry standards prior to using MEDICLEAN DISINFECTANT SPRAY PLUS Some (but not all) of the conditions that would indicate the need for major repairs or replacement of the system include:
• Improper size of ducts – Ducts must be sized to achieve correct airflow. When air-handling equipment is changed or new inlets or outlets added, the size of all components in the system should be recalculated and replacements made as needed.
• Physical damage – Crushed or deformed air ducts will restrict airflow and may leak (especially at joint areas). Damaged sections should be replaced or if there is extensive damage, the entire system should be replaced.
• Badly corroded metal components including duct sections, housings and cabinets, coil assemblies, drain pans, fans and their housings and heat exchange surfaces.
• Loose, damaged, friable or missing insulation – Insulation is important in preventing moisture condensation and subsequent growth of mold and other organisms. If insulation (either interior or exterior) is damaged, missing or not properly fastened it must be repaired or replaced or the associated duct sections replaced. Air handler, mixing, and VAV box housings are also normally insulated and this insulation should be checked for damage in a like manner.
Removed components that are contaminated with mold and other microbial growth may spread contamination while being removed from the building. To prevent this, smaller items should be placed in plastic bags that should then be sealed before being removed. Larger items that cannot be safely packaged should be treated before being moved through occupied spaces. An appropriately labeled disinfectant can be used during treatment. Care must be used during treatment to assure that fumes from the agent being used are not released into occupied spaces. Products used should be used according to their label directions. Please contact ProRestore® Products at 800-332-6037 for guidance on the appropriate disinfectant to use for treatment.
3.0 General Directions for MEDICLEAN DISINFECTANT SPRAY PLUS Usage. MEDICLEAN DISINFECTANT SPRAY PLUS effectively controls by inhibiting growth of odor causing bacteria, fungi, and other odor, stain or damage causing organisms in air ducts in residential, commercial, and industrial buildings. MEDICLEAN DISINFECTANT SPRAY PLUS also eliminates odors associated with bacteria, mold, mildew, smoke, animals, cooking, spoilage, musty and other odors and removes odor-causing organisms when used as part of such a comprehensive preventative maintenance program in air ducts and other HV AC system components.
MEDICLEAN DISINFECTANT SPRAY PLUS is a bacteriostat, fungistat (mold and mildew), mildewstat and deodorizer for use in residential, commercial and industrial settings. It will not stain or bleach materials or fabrics and will not harm or damage HVAC system components.
MEDICLEAN DISINFECTANT SPRAY PLUS is formulated for use in all kinds of ducts and HVAC components including:
- Unlined sheet metal. - Air supply and return ducts and plenums fabricated with plywood, OSB or other wood like material.
- Flexible air ducts fabricated of metal or plastic. - Air distribution components such as air handlers, mixing boxes, transfer boxes, transitions, turning vanes, dampers, fans and fan housings and associated components.
- Condensate drain pans.
Follow the directions below for the specific type of duct or component being treated. It is vital that the following directions be carefully read and understood prior to using the product. If you have any questions, need further information, require clarification, or do not understand any of the directions, call ProRestore® Products at 800-332-6037 prior to use.
3.1 Application Instructions. Spray areas until thoroughly moist, giving special attention to cracks and crevices. Allow ten to twenty minutes for drying. It is not necessary to wipe the sprayed surface. MEDICLEAN DISINFECTANT SPRAY PLUS should not stain those materials not stained by water.
3.2 Application Equipment and Devices. Refer to the precautionary statements for the Personal Protective Clothing and other special instructions that must be followed.
3.2.1 Brush, Mop or Wipe Application. Brush, Mop or Wipe Application may be specified by some facility maintenance or remediation plans. These techniques are generally more labor intensive than other methods and are normally used only when specifications require. These methods are suitable only for smooth uniform surfaces. Do not use on porous or non-uniform surfaces. If in doubt about a given surface, contact ProRestore® Products at 800-332- 6037 before proceeding. When using brush or mop application, tools and materials used should be reserved only for application of MEDICLEAN DISINFECTANT SPRAY PLUS kept clean and protected between uses and replaced when worn or visibly soiled. Natural fiber brushes are preferred although any quality brush is acceptable. Mops types should be those that leave minimal lint behind. Micro-fiber or other non linting cloths are preferable. Where other types of cloths are used, they must be soft enough that they absorb a sufficient quantity of liquid to provide uniform application. During Brush, Mop or Wipe Application, the applicator must have access to the surfaces being treated. Usually this will require entering the ducts. In such cases, application must start from the point most distant from the point of entry into the duct. The applicator will then work from that point back to the entry point covering a 3 foot length of duct at a time. Apply to the top of the duct first, followed by the sides then the floor of the duct. Overlap applications to assure complete coverage. Cover completely while avoiding runs or pooling.
3.2.2 Spray Applicators. Spray application is preferred on large surfaces that are easily accessible (such as in long runs of large diameter ducts, coil assemblies and the interior of cabinets and housings with removable access panels). The spray equipment chosen should provide a consistent fine (1-300 micron) particle size and uniform spray pattern. Powered medium pressure sprayers are preferred. However, airless sprayers are suitable.
Where airless sprayers are used, the most satisfactory spray pattern will be achieved using a 0.011” spray tip. For other brands and options contact ProRestore® Products at 800-332-6037.
Pump up garden type sprayers can be used but care must be taken to maintain maximum pressure by pumping frequently and the spray nozzle must be adjusted for the finest spray pattern possible. During application achieve complete uniform coverage. Avoid excessive wetting and do not allow the spray to run or pool.
3.2.3 ULV or Mist Generating Sprayers. ULV or mist or other wet small particle application is preferable where surfaces are irregular or less accessible. Equipment capable of generating particles in the 15 to 60 micron range is most satisfactory. Avoid use of thermal type fog generators. Contact ProRestore® Products at 800-332-6037 for information on other devices. Generally a fog will carry and provide adequate coverage up to 8 feet from the point of application so adequate penetrations must be cut in the ducts to assure complete coverage without over wetting. SMACNA, NADCA and NAIMA have established standards and guidelines for making and sealing openings in ducts.
Operators should be trained on proper application techniques as well as correct duct penetration and sealing procedures using these standards and guidelines. Operators should also carefully read and follow directions for the brand of equipment used. ProRestore® Products personnel should be contacted at 800-332-6037 for information on training for using various types of equipment. Duct penetrations should be properly closed following application, in accordance with industry standards.
3.2.4 Automated Atomizing or Spray System. There are a number of automated spraying systems on the market including those that are carried by a “robot” through air ducts. These may provide an excellent option for application of MEDICLEAN DISINFECTANT SPRAY PLUS in parts of air ducts that are difficult to access if they produce the correct spray pattern and application quantity. These devices must be visually monitored using video or other means while applying spray so proper application rate will be maintained. Please contact ProRestore® Products at 800-332-6037 regarding a specific device should you have questions.
3.3 Application Techniques. MEDICLEAN DISINFECTANT SPRAY PLUS must be applied evenly throughout duct system and over other surfaces that are being treated. Even and uniform application is essential for satisfactory results.
The procedures, equipment and techniques described below have been tested and provide the desired results. Other procedures, equipment or techniques may also achieve satisfactory results but should not be used without discussing the specific situation and equipment with a ProRestore® Products Representative who can be reached toll free at 800-332-6037.
3.3.1 Application from Exterior of the HVAC System. MEDICLEAN DISINFECTANT SPRAY PLUS may be sprayed into openings at intervals throughout the duct system or on components that are accessible through removable panels or access doors. Spray into openings every 8 feet at a minimum. Existing supply openings can be used where they provide a clear view of the surfaces being sprayed so that uniform application can be achieved. However, additional penetrations will have to be made as needed, so enough openings will be available to achieve total and uniform coverage.
Spray application is not an acceptable technique where openings are greater than 8 feet apart, additional openings cannot be made and properly sealed, and/or the duct geometry does not allow for uniform coverage. In such cases, application from within the HVAC system is necessary (see 3.3.2 below).
3.3.2 Application from Within the HVAC System. When MEDICLEAN DISINFECTANT SPRAY PLUS cannot be sprayed into openings at intervals throughout the duct system, you must gain entry into the system and spray the product onto interior duct and…
This is the start of the file's text. The full file is on GovTribe.