View the file

Other files

File Type Posted
36C24622Q0224_4.docx DOCX document
ECR5_3.jpg JPG image
36C24622Q0224_2.docx DOCX document
ECR6.jpg JPG image
S02 Amendment - 36C24622Q0224_1.docx DOCX document
ECR (002).png PNG image
ECR1.jpg JPG image
ECR7.jpg JPG image
ECR8.jpg JPG image
ECR2.jpg JPG image
ECR4.jpg JPG image
ECR3.jpg JPG image
ECR5.jpg JPG image
36C24622Q0224.docx DOCX document
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment to Previous Combined Solicitation – 36C24622Q0224 Amendment to a Previous Combined Solicitation See attached document: ECR5.

SUBJECT*
EXECUTIVE CONFERENCE ROOM UPGRADE Veteran-Owned Small Business Set-Aside Combined Synopsis Amendment 36C24622Q0224_3

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
23667
SOLICITATION NUMBER*
36C24622Q0224
RESPONSE DATE/TIME/ZONE
01-21-2022 8 AM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
VSA
PRODUCT SERVICE CODE*
5836
NAICS CODE*
334310

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs Network Contracting Office 6 100 Emancipation Drive Hampton VA 23667

POINT OF CONTACT*

Contracting Officer James Risbon james.risbon@va.gov 757-728-7128

PLACE OF PERFORMANCE

ADDRESS
Department of Veterans Affairs

Charles George VA Medical Center

1100 Tunnel Rd.

Asheville NC

POSTAL CODE
28805

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS
james.risbon@va.gov

EMAIL DESCRIPTION

DESCRIPTION

*= Required Field
Amendment to a Previous Combined Solicitation

Page 1 of

Amendment to a Previous Combined Solicitation

Combined Synopsis Amendment 36C24622Q0224-3

Executive Conference Room Upgrade

The following responses are to vendor questions that were not answered on Amendment 36C26422Q0224_2 and an additional question submitted on 1-18-2022.

Questions (Are in black) / Answers: (Responses are in red)

1. Response to Question #2 of Amendment 36C24622Q0224_2. Space between chair rail and ceiling?

Depending on the spacing, the 86” display may not fit on wall.

There is 58” from the ceiling to the rail…however I’ve included a picture of the mounting system behind the current set up. If a bigger screen is installed, it can be mounted away from the existing chair rail. If that is not satisfactory to the vendor, we can have the chair rail removed.

(See attached photo ECR5)

2. Response to Question #5 of Amendment 36C24622Q0224_2. Can you please provide details about what type of project’s onsite support is required? The solicitation mentioned “Onsite” but then did not expand.

We want access to troubleshooting service 24/7/365 via email, phone, text, or chat to address any issues that come up. Since this service will not be managed by our local OI&T, we need a company that will be able to remote in and service the system. If a company offers a similar service, it needs to be quoted. We need some type of service contract.

3. We see that in one of the responses, you are looking for all (4) displays to be interactive touch screens. We reviewed this with our engineers in great detail and unfortunately it is not possible to simultaneously have touch capacity and annotation in all (4) displays AND have the same content repeated on all (4) displays. Each touch display needs to be driven by its own individual PC which would mean you’d need (4) total rack PC’s to allow for the annotation/touch functionality on each display.

If you did have (4) total rack PC’s, you still would not be able to “repeat” the same signal/content across all (4) displays. Typically, what we’d recommend here is to dedicate one display (we’d suggest the 86in) as the touch and annotation display which is driven by the rack PC. Then for the (3) remaining 75in displays, we can easily repeat that content/signal from the 86in across the 75in which would essentially serve as confidence monitors. You wouldn’t be able to annotate on the 75in displays but you’d at least be able to view the content and annotation that is being done on the 86in display.

I think the vendor misunderstood the proposal. We want a main interactive screen and a touch screen console to control all the equipment. Whatever is on the main screen needs to be repeated on all screens so all persons in the room can see the same thing.

End of Questions/Answers response for Amendment 36C24622Q0224_3.

The following responses are to vendor questions that were submitted on 1-12-2022.

Questions (Are in black) / Answers: (Responses are in red)

1. If you are able to extend the RFQ through mid to later part of next week, that would be extremely helpful.

Yes, the closing date for 36C24622Q0224 has been extended to 8 AM, EST next Friday (1-21-2022). To allow response time to post results of the two questions that are still being reviewed.

2. Space between chair rail and ceiling? Depending on the spacing, the 86” display may not fit on wall.

Spacing is being reverified and results will be posted on Amendment 36C24622Q0224_3.

3. Will they be using an analog phone line?

The facility is in the process of switching over to VOIP.

4. Do you need a touch screen? Especially 86” when they have 3 other 75” Displays in the room?

Yes, we are requesting for all displays to be touch screens.

5. Can you please provide details about what type of project’s onsite support is required?

The solicitation mentioned “Onsite” but then did not expand.

Question has been forwarded for review and response will be posted on Amendment 36C24622Q0224_3.

Additional submitted questions from 1-11-2022.

Questions (Are in black) / Answers: (Responses are in red)

1. VOIP or POTS line – explain what a POTS line POTS line is an analog phone line. Note: The facility is in the process of switching over to VOIP.

2. What is being requested via Parasol is support that can be provided to you without the subscription from Parasol. Would the VA be open to alternatives and allow for us to quote and provide our helpdesk 24x7x365 support instead?

Yes, the facility would be open to a similar product.

End of Questions/Answers response for Amendment 36C24622Q0224_2.

The following responses are to vendor questions that were submitted on 1-11-2022.

Questions (Are in black) / Answers: (Responses are in red)

3. Room dimensions – The size of the room is 26” x 24”, see attached blueprint.

4. Wall material – drywall

5. Ceiling material (type of ceiling) – drop ceiling

6. Floor material (raised floor?) – carpet

7. How many people sit at the table – varies cannot provide a solid number

8. VOIP or POTS line – explain what a POTS line

9. Use existing cabinet or new one – depends on amount of equipment

10. Pictures of the room would be great if available – see attached.

See attached document: ECR8.

See attached document: ECR7.

See attached document: ECR6.

See attached document: ECR5.

See attached document: ECR4.

See attached document: ECR3.

See attached document: ECR2.

See attached document: ECR (002).

See attached document: ECR1.

End of Questions/Answers response for Amendment 36C24622Q0224_1.

Amendment to Previous Combined Solicitation - 36C24622Q0224

Page 1 of Page 1 of

Amendment to Previous Combined Solicitation - 36C24622Q0224

File details come from the government source that posted it. Updated .