D Wing Drawings 121 to 177.pdf

PDF 39 MB Posted

Attached to
Y1DZ--Expand Building 1 D-Wing Project No: 565-135
Solicitation number
36C24621R0050
Issued by

About this file

This document outlines a federal contract opportunity for the expansion of Building 1 D-Wing at the Fayetteville VA Medical Center. The subsequent solicitation will be a request for proposal to construct a planned 24,800 gross square foot expansion on the southeast elevation of Building 1, including demolition of Building 8. The expansion will add a 4-story elevator shaft and patient drop-off canopies. The basement level will expand emergency room facilities. The first floor will include additional waiting areas, consult offices, and staff support spaces. The solicitation number is 36C24621R0050 and will be posted on or about May 28, 2021. The associated NAICS code is 236220 for commercial and institutional building construction, with a small business size standard of $39.5 million. The federal agency is the Department of Veterans Affairs Veterans Health Administration VISN 6.

View the file

Other files

File Type Posted
36C24621R0050 0005.pdf PDF
Statement of Proposal Items.docx DOCX document
EXPAND BLDG. 1 D WING_ADDENDUM A DRAWINGS (17 total).pdf PDF
Specification Section 01 00 00 - R 06.22.2021.docx DOCX document
LISTING OF DRAWINGS.pdf PDF
36C24621R0050 0004.pdf PDF
36C24621R0050 0003.pdf PDF
FNCVAMC Lead Survey 2003 includes Building 8 - Part 1.pdf PDF
Bldg 8 Fire Alarm Replacement 1990.pdf PDF
B 4_5_8 Heat Pumps and Solar Sht 4 of 5 1983.pdf PDF
Dec 2016 Subsurface and Geotechnical Analysis for Expand D-Wing Project.pdf PDF
B 4_5_7_8 Heat Pumps and Solar Sht 5 of 5 1983.pdf PDF
Building 8 Lead Based Paint Survey Results 2003.pdf PDF
Telephone System Replacement Bldg 8-E1 Electrical 1984.pdf PDF
B 4_8 Heat Pumps and Solar Sht 3 of 5 1983.pdf PDF
Specification Section 09 24 00 - Portland Cement Plastering.pdf PDF
B 4_5_7_8 Heat Pumps and Solar Sht 1 of 5 1983.pdf PDF
Building 8 ACM Survey 2004.pdf PDF
FNCVAMC Lead Survey 2003 includes Building 8 - Part 2.pdf PDF
36C24621R0050 0002.pdf PDF
36C24621R0050 0001.pdf PDF
D Wing Drawings 51 to 120.pdf PDF
D Wing Specifications Vol 1.pdf PDF
D Wing Drawings 1 to 14.pdf PDF
D Wing Drawings 15 to 25.pdf PDF
D Wing Specifications Vol 2.pdf PDF
D Wing Drawings 26 to 50.pdf PDF
36C24621R0050_1.docx DOCX document
36C24621R0050.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

75432

B

C

D

E

AA

1 6

A.AA AA AA AA AA AA AA AAAAAAA

OPEN

OFFICE

AREA

(OFA09)

CONSULT

(EXRG3)

TOUCH

DOWN

(OFA09))))

CONSULTO

(EXRG3)EXEXE(EXEX((EE

102311

CONSULTCOOOOOOO

(EXRG3)

TOUCH

DOWN

(OFA09)

10191000

IT

STORAGE

(SRE01)

ELEV.

VESTIBULE

CLINICALL

ELEVATOREELEE TOR

60756076070

RECEP.

(RCED1)

ELECTRICAL

CONSULTULUULUL

(EXRG3)G3)))GG3

CONSULT

(EXRG3)

CONSULT

(EXRG3)3)))G3G3

S. TLTSS

(TNPG1)

CORRIDOROCORRIDOROCORRIDORORCORRIDORDOC DCORRIDORDOC D

TOUCH

DOWN

(OFA09))))))

CONSULT

(EXRG3)RRRXRREXX(EE

1013000

HAC (JANC1)(

TLT (TNPG1)TTTTTTLTLTT ((

EQUIP

(SRE01)

WAITING

AREA

(WTG20)

CORRIDOR

B.6

D.3

3.1

TOUCHTOUC

DOWN

(OFA09)

A.A.1A

A.A.2A

4.13.9 4.3

H

E.1

A.4 -

1.9 2.6

C.9

TOUCHTOUCH

DOWN

(OFA09))(

10281000

HHTOUCCCCHH

DOWNN

(OFA09)9

10301030

CONSULTTLTLLLL

(EXRG3)

STORAGE

(SRE01)

10321032

CONSULT

(EXRG3)

1018100180 8888

CORRIDOR

CORRIDOR

WORKWORK

(NSTA1)

M. TLT.

(TNPG1)

WM. TLT.

(TNPG1)

103511

CONSULT

(EXRG3)G3G3G33G3)3

CORRIDOR

10091009

OPEN

OFFICE

AREA

(OFA09)

BREAK/LOCKERS

(SLO01)

CORRIDOR

TLT (TPG01)(

1039CONSULTULTON

(EXRG3)RGG3G3)3RRRR

103803030

CORRIDORC

CORRIDORO

48" e7 e8 e9 eA2eB e6 e5ee

5.81.95

A.0

1.2.

STAIR OCCUPANTSSS

LOAD: 113L

CAPACITY: 160C

DOOR OCCUPANTSD

LOAD: 113L

CAPACITY: 240C

STAIR OCCUPANTSSS

LOAD: 134L

CAPACITY: 140C

DOOR OCCUPANTSD

LOAD: 134 (125 EXISTING + 9 NEW)T GL

CAPACITY: 220C

* OCCUPANTS*

FROM THIS AREAF

ONLY WILL EXITO

THROUGHT

EXISTING STAIRE

FEC

FECE

FECE

FECE

FEC

FEC

44"

CO

DUE TO EXISTINGD

CONDITIONS 13ONS 13DITCOCC

OCCUPANTS OF EXISTINGO

BUILDING WILL USE THESB

NEW CONSTRUCTIONIN

EGRESS STAIRE

CCESS HATCH INC2 HR AC

WALL

TO ACCESS FLOOREC

MOUNTED SMOKEET

ERS IN THE SHAFTRDAMPEE

DND

8'- 0"

NEW CONSTRUCTION

TYPE 1 (332)E

HEALTHCARE OCCUPANCYL

EXISTING CONSTRUCTION

TYPE 2 (111)

AMBULATORY HEALTHCARE OCCUPANCY

SMOKE BARREIR, 2-HOUR OCCUPANCY SEPARATION,

AND 2-HOUR CONSTRUCTION TYPE SEPARATION

FHV

FHVFHVFF

KEY PLAN: FIRST FLOOR

1/8" = 1'-0"F3 FIRST FLOOR FIRE PROTECTION PLAN

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS - FULLY SPRINKLERED

Z W o rk A tr ia x

G ro u p V A

F a y e tt e v il le

D

W in g F ro m

T o n y V A

F a y e tt e v il le

D

W in g

F P

F ir s t F lo o r P L A N .d w g

:4 :5

A M

W o rk s ta ti o n www.atriaxgroup.com

Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 Phone: 828.315.9962 Fax: 828.315.9964

NC Engineering License No.: P-0214 NC Architectural License No.: 51254

8845 Red Oak Blvd.

Charlotte, NC 28217-5593

Phone: 704.523.2230 Fax: 704.523.2235 www.freemanwhite.com

FreemanWhite

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

8701 Red Oak Blvd.

Charlotte, NC 28217-5593

Phone: 704.522.0495 Fax: 704.522.0499 www.lrspc.net

LeGrand Engineering, Inc.

215 Park Ave SE Aiken, SC 29801

Phone: 803.502.0657 Fax: 803.643.4648 www.legrandengineering.com

RMaddox Image

(E)CO

(E)CO

(E)2" W UP

(E)2" W UP

(E)2" V UP

(E)2" V UP

(E)4" RL DN

(E)4" RL UP

(E)4" W UP

CAP

(E)4" W

(E)4" RL

(E)3" W

(E)2" V

(E)4" W

BB

CC

AA

A.AA.A

B.6B.6

A.A.2A.A.2

A.4A.4

1.9

1.9 e7 e8 e9 eA2eB e6

1.95

1.95

A.0A.0

1.2

1.2

(E)1 1/2" DCW

(E)1" DHW

(E)1/2" DHWR

(E)1/2" DCW

& DHW

(E)1/2" DCW

& DHW

(E)3/4" DHW

(E)3/4" DCW

(E)3/4" DCW

CAP

(E)3/4" DCW

BB

CC

AA

A.AA.A

B.6B.6

C.3C.3

A.4A.4

1.9

1.9

1.95

1.95

1.2

1.2

A.0A.0

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL SANITARY WASTE PIPING IS BELOW FLOOR. ALL VENT AND WATER

PIPING IS ABOVE CEILING, UNLESS NOTED OTHERWISE.

ABANDONED PIPING AND HANGERS TO BE REMOVED.

ABANDONED OR DEMOLISHED BRANCH WATER LINES SHALL BE REMOVED

BACK TO MAIN AND CAPPED WITHIN 2" OF THE MAIN LINE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

1.

2.

3.

4.

5.

KEYED NOTES

1 REMOVE EXISTING PLUMBING FIXTURES. CAP PIPING ABOVE

CEILING AT MAIN AND BELOW FLOOR.

REMOVE EXISTING EXTERIOR WALL HYDRANTS. CAP PIPING

ABOVE CEILING AT MAIN SERVING HYDRANTS. VERIFY LOCATION.

REMOVE EXISTING 3/4" DCW PIPING BELOW GRADE SERVING

EXISTING YARD HYDRANT. CAP PIPING ABOVE CEILING AT MAIN.

VERIFY LOCATION.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

T H

IN

C

O

N E

F

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

R

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

S

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

L

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

D

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING PARTIAL GROUND

FLOOR DEMOLITION PLANS

PD101

HAS SLC

1/8" = 1'-0"1

PARTIAL GROUND FLOOR DEMOLITION PLAN - WASTE & VENT

1/8" = 1'-0"2

PARTIAL GROUND FLOOR DEMOLITION PLAN - WATER

2BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

Revision 0 07/07/2020

(E)2" V UP (E)2" V DN

CAP

(E)4" RL DN

(E)4" RL UP

(E)2" V DN (E)2" V UP

BB

CC

AA

A.AA.A

B.6B.6

A.A.1A.A.1

A.A.2A.A.2

A.4A.4

1.9

1.9

C.9C.9 e7 e8 e9 eA2eB e6

1.95

1.95

A.0A.0

1.2

1.2

B

C

A

A.A

CAP

(E)1 1/4" DCW

(E)1/2" DHW

B.6

C.3

BB

CC

AA

A.AA.A

B.6B.6

C.3C.3

A.4A.4

1.9

1.9

1.95

1.95

1.2

1.2

A.0A.0

KEYED NOTES

REMOVE EXISTING PLUMBING FIXTURES. CAP PIPING ABOVE

CEILING AT MAIN AND BELOW FLOOR.

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL SANITARY WASTE PIPING IS BELOW FLOOR. ALL VENT AND WATER

PIPING IS ABOVE CEILING, UNLESS NOTED OTHERWISE.

ABANDONED PIPING AND HANGERS TO BE REMOVED.

ABANDONED OR DEMOLISHED BRANCH WATER LINES SHALL BE REMOVED

BACK TO MAIN AND CAPPED WITHIN 2" OF THE MAIN LINE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

1.

2.

3.

4.

5.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING PARTIAL FIRST

FLOOR DEMOLITION PLANS

PD102

HAS SLC

1/8" = 1'-0"1

PARTIAL FIRST FLOOR DEMOLITION PLAN - WASTE & VENT

1/8" = 1'-0"2

PARTIAL FIRST FLOOR DEMOLITION PLAN - WATER

3BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

BB

CC

D D

E E

AA

A.AA.A

4" W

2" W UP

4" W RISER

3" W UP

2" V UP 2" W UP

2" W UP

6" RL UP

(2502 sq. ft)

2" W UP

2" W UP

4" W UP

2" W UP

2" W UP

4" W

2" V UP

3" W UP

4" W UP

4" W

3" W UP

TO FD

3" V UP

3" W UP

TO FD

3" W UP

TO FD

4" W UP

TO FCO

3" W UP

4" W

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

3" V UP

2" W UP

4" W UP

2" W UP

2" W UP

2" W UP

4" W

2" W

4" W

2" W

4" W

2" W UP

2" V UP

4"W UP

TO FCO

4" W

2" W

2" W UP

2" W UP2" W UP2" W UP

4" W

4" W

4" W

4" W

2" W

2" W

2"W UP

4"W UP

TO FCO

4" W

2" W

4"W UP

TO FCO

4" W

4" W

4"W UP

TO FCO

2" W UP

2" W

SUMP PUMP SP-1

2"W UP

4" W UP

TO FCO

4" W

2" W

4" W

4" W 2" W

6" W

2" W

2" W

4" W

4"W RISER

4"W RISER

2" W

4" W

4" W

4" W

3" W

3" W

4" W

4"W UP

2"W UP

2"W UP

2"W UP

2"W UP

2"V UP

2"W UP

4"W UP

TO FCO

4"W UP

TO FCO

4"W UP

TO FCO

6" W. BELOW GRADE.

INVERT 191.79'

SEE CIVIL DRWGS. FOR

CONTINUATION.

2"CRP UP2"CRP UP2"CRP UP2"CRP UP

2"CRP2"CRP2"CRP

2"CRP

4" W

3" W UP

TO FD

4" W

4" W

4" W

4" W

4"W UP

TO HD

2" W

4"RL UP

(1877 SQ. FT.)

4"RL BELOW GRADE.

(1877 SF) INV. 192.96'

SEE CIVIL DRWGS.

FOR CONTINUATION.

4"RL UP

(703 SQ. FT.)

4"RL BELOW GRADE.

(703 SQ. FT.) INV. 192.96'

SEE CIVIL DRWGS.

FOR CONTINUATION.

6" RL UP

(2736 SQ. FT.)

6"RL UP

(2769 SQ. FT.)

6"RL UP

(2991 SQ. FT.)

8"RL

(5760 SQ. FT.)

6"RL UP

(1609 SQ. FT.)

6"RL UP

(1634 SQ. FT.)

8"RL

(4370 SQ. FT.)

8"RL

(8481 SQ. FT.)

8"RL

(6872 SQ. FT.)

10"RL

10"RL BELOW GRADE.

(14,241 SQ. FT.) INV. 191.29'

SEE CIVIL DRWGS. FOR

CONTINUATION.

6"RL

(1609 SQ. FT.)

RL RL

RL RL

R L

R L

FINISHED FLR. ELEV.

196.29'

2"CRP

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL SANITARY WASTE PIPING AND RAIN LEADER PIPING IS BELOW

FLOOR. ALL VENT PIPING IS ABOVE CEILING, UNLESS NOTED

OTHERWISE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

COORDINATE PIPING INSTALLATION WITH STRUCTURAL FOOTINGS.

1.

2.

3.

4.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING FOUNDATION PLAN

-WASTE & VENT

PL100

HAS SLC

1/8" = 1'-0"1

PLUMBING FOUNDATION PLAN - WASTE & VENT

4BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

BB

CC

D D

E E

AA

A.AA.A

P-935

P-528

FCO

WCO

WCO

4" W RISER

6" RL UP

(1634 sq. ft)

4" W UP

2" V DN

CO

6" RL UP

(2502 sq. ft)

2" W UP

4" W UP

2" V DN

3" V RISER

3" V UP

FCO

FCO

6" OD UP

(1609 sq. ft)

4" W UP

6" RL UP

(1609 sq. ft)

6" RL DN

(1609 sq. ft)

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

P-520

P-528

P-528

P-418

P-418

3" V UP

P-524

P-418

FCO

FCO

FCO

P-113

P-528

P-113

P-420

P-701

P-502

P-111 P-420

P-910

P D

P D

4"W RISER

3"V RISER

3"V RISER

4" W RISER

WCO

3" V

3" V

3" V

3" V

2" V 3" V

3" V

2" V

2" V

2" V

2" V

2" V 2" V

2" PD

2"PD FROM ELEV.

SUMP PUMP SP-1

2" PD

2" V

3" V

2" V

2" V

2" V

2" V

2" V

2" W UP 2" W UP 2" W UP

2" W UP

2" W 2" W

3" W 2" W

4" W

4" W

4" W

4" W

4" W

3"W UP

2"V UP

3" W4"W UP

4"W UP

4"W UP

2"W UP

3"W UP

3"V UP

3"W UP

4" W

3" W

2" V

4" W 2" V 2" V

2"W UP

2" W

2" W

3" W

2"W UP 2"W UP

2"W UP

2" W 2" W

2" W

3" W

2"W UP

2"W UP

2"W UP

2" W

2" W

2" W

2" W UP

2" W

2"W UP

2" W

4"W UP

4" W

2"W UP

2" W 4" W

2"W UP

2" W

CO

4"OD

(1877 sq. ft..)

4"RL RISER

(1877 sq. ft.)

3"FD-C

W/T.P.

2" V 2" V 2" V

2" V 2" V

P-910

3" V

3" V

P-528 P-528

P-528

P-935

P-528P-528

2" V 2" V

BB

CC

D D

E E

AA

A.AA.A

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

5.8

5.8

A.4A.4

1.9

1.9

2.6

2.6

4.1

4.1

1.95

1.95

1.2

1.2

6.9

6.9

A.0A.0

C.9C.9

3" V

CO

2"PD DN

TO 4"HD

4"HD W/T.P

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3" V 2" V

2" V

2" V

3" V

FCO

CO

2"FD-C

W/T.P.

2" V

4"OD RISER

(703 sq. ft.)

4"RL RISER

(703 sq. ft.)

4" W

6" OD

(1609 sq. ft.)

3" V

3" W

B.H. EXAM 7 (OPMH4)

EXAM 4 (TRET4)

EXAM 3 (TRET4)

EXAM 1 (TRET4)

CLINICAL ELEVATOR

CONSULT (OFDC2)

MECH / PUMBING

STAFF BREAK (SLO01)

TRIAGE 2 (EXTR1)

TRIAGE 01 (EXTR1) 0005

SECURITY (RCSS2)

0001D

HSKP. (JANC1)

0001E

ELECTRICAL

EQUIP (SRE01)

B.H. EXAM 8 (OPMH4)

0001A

VESTIBULE (LOB02)

MEDS (MEDP1)

P. TLT (TPG01)

HAC (JANC1)

NOURISH (NCWD03)

B.H. EXAM 10 (OPMH4)

STAIR

0001B

WC/ STRETCHER

(SRLW1)

0001C

NURSE / RECEPTION

(RCED3)

WAITING (WTG20)

TEAM STATION POD 2

(NSTA4)

TEAM STATION POD 1

(NSTA1)

0006B

CORR

TRAUMA BAY (TRET3)

EXAM 2 (TRET4)

IT

CLEAN LINEN (SRE01)

TLT (TNPG1)

WORK (NSTA1)

SOILED UTILITY (USCL1)

CLEAN UTILITY (UCCL1)

TLT (TNPG1)

CORRIDOR

ELEV. CONTROL

0030A

BARIATRIC B.H. TLT

(TPMH1/TPB01)

0033A

B.H. PATIENT TOILET

ROOM (TPMH1)

B.H. EXAM 9 (OPMH4)

0026A

S. TLT. (TNPG01)

B.H. EXAM 5 (OPMH4)

BARIATRIC B.H. EXAM 6

(TRET6/OPMH4)

P. TLT (TSPG1/TPMH1)

CORR

1032FF

CORR

1011E

BAY - 8

1011L

BAY - 10 ACUTE RM

FEMALE TLT

0001F

FEMALE TLT S014

STAIR

Room

CORRIDOR

POLICE/SECURITY RM

VESTIBULE

EMERGENCY

ENTRANCE

BAY - 7 OBSERVATION

ROOM

EXISTING TOILET

EQUIP (SRS01)

6" OD UP

(2502 sq. ft)

6" RL UP

(2736 sq. ft)

6" OD UP

(1634 sq. ft)

6" OD UP

(2736 sq. ft)

8"OD UP

(2769 sq. ft.)

6"RL UP

(2769 SQ. FT.)

6"RL UP

(1060 SQ. FT.)

6"OD UP

(1931 sq. ft.)

6"RL DN.

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

O D

O D

O D

O D

R L

R L

O D

OD

O D

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

P-111

P-111

P-420

P-420

P-609

P-528

P-524

P-708

P-708

P-505

DOMESTIC BOOSTER PUMP SYSTEM

DBP-1. SEE SCHEDULE SHT. PP602

AND DETAIL 1, SHT. PP502.

4"RL IN SOFFIT.

SLOPE 1/4" PER

FOOT.

4"OD IN SOFFIT

SLOPE 1/4" PER

FOOT.

4"RL IN SOFFIT

4"OD IN SOFFIT

6" OD

(1931 sq. ft.)

8" OD

(2769 sq. ft.)

6" OD

(1634 sq. ft.)

6" OD

(2502 sq. ft.)

TERMINATE OVERFLOW

DRAIN 12" ABOVE GRADE

WITH DOWNSPOUT NOZZLE.

4"OD UP

(1877 sq. ft.)

4"RL UP

(1877 sq. ft.)

4"RL UP

(703 sq. ft.)

4"OD UP

(703 sq. ft.)

FCO

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS.

ALL SANITARY WASTE & VENT PIPING AND RAIN LEADER PIPING IS

ABOVE CEILING. UNLESS NOTED OTHERWISE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

PROVIDE WALL CLEANOUTS AT THE BASE OF ALL SANITARY AND STORM

RISERS.

1.

2.

3.

4.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING BASEMENT PLAN-

WASTE & VENT

PL101

HAS SLC

1/8" = 1'-0"1

PLUMBING BASEMENT FLOOR PLAN - WASTE & VENT

5BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

BB

CC

D D

E E

AA

A.AA.A

6" OD UP

TO OD-1

6" RL UP

TO RD-1

6" OD UP

TO OD-1

6" RL UP

TO RD-1

6" RL UP

TO RD-1

8" OD UP

TO OD-1

6" RL UP

TO RD-1

6" OD UP

TO OD-1

6" OD UP

TO OD-1

6" RL UP

TO RD-1

CO

6" RL DN

(2502 sq. ft)

6" OD DN

(1931 sq. ft)

6" RL DN

(2736 sq. ft)

6" OD DN

(1634 sq. ft)

6" OD DN

(1609 sq. ft)

6" RL DN

(1609 sq. ft)

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

3" VTR

4" W RISER DN

3" V RISER

3" V DN

4" VTR

2" V 2" V

3" V

2" V3" V

3" V

2" V

2" V 3" V

2" V

3" V

3" V 2" V

2" V

2" V

2" V

2" V2" V

2" V

2" V

3" V

4" W RISER DN

3" V RISER2" V

2" V

4" VTR

4" W RISER DN

3" V RISER

2" V

3" V

3"FD-C

W/T.P.

3"FD-C

W/T.P.

P-111

P-111

P-111

P-420 P-420 P-420

P-420 P-420 P-420

P-111

P-204

P-418 P-502

P-524

P-111 P-420

P-111

P-420

P-418

P-418

P-418

P-418

P-418

P-418 P-418

P-418 P-111

P-420

P-418

UP TO 4"RD-1

(1877 SF)

UP TO 4"OD-1

(1877 SF)

BB

CC

D D

E E

AA

A.AA.A

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

5.8

5.8

A.4A.4

1.9

1.9

2.6

2.6

4.1

4.1

1.95

1.95

1.2

1.2

6.9

6.9

A.0A.0

C.9C.9

3"V FROM BELOW.

3"VTR

3" V

UP TO 4"RD-1

(703 SF)

UP TO 4"OD-1

(703 SF)

P-111

P-111

6" OD DN

(2736 sq. ft)

6" RL UP

TO RD-1

6" OD UP

TO OD-1

6" RL DN

(1634 sq. ft)

4" VTR

6" OD DN

(2502 sq. ft)

CO

6" OD DN

(1060 sq. ft)

4" RL UP

TO RD-1

6" RL DN

(2769 sq. ft)

8" OD DN

(2769 sq. ft)

6" RL DN

(2991 sq. ft)

6" RL UP

TO RD-1

OPEN OFFICE AREA

(OFA09)

CONSULT (EXRG3)

TOUCH DOWN (OFA09)

CONSULT (EXRG3)

CONSULT (EXRG3)

TOUCH DOWN (OFA09)

WORK (NSTA1)

IT

STORAGE (SRE01)

ELEV. VESTIBULE

CLINICAL ELEVATOR

RECEP. (RCED1)

ELECTRICAL

CONSULT (EXRG3)

CONSULT (EXRG3)

CONSULT (EXRG3)

S. TLT (TNPG1)

CORRIDOR

TOUCH DOWN (OFA09)

CONSULT (EXRG3)

TOUCH DOWN (OFA09)

CONSULT (EXRG3)

HAC (JANC1)

TOUCH DOWN (OFA09)

WM. TLT. (TNPG1)

TLT (TNPG1)

EQUIP (SRE01)

WAITING AREA (WTG20)

CORRIDOR

CONSULT (EXRG3)

STORAGE (SRE01)

CONSULT (EXRG3)

CORRIDOR

CORRIDOR

ALCOVE

TLT (TPG01)

BREAK/LOCKERS

(SLO01)

CORRIDOR

CORRIDOR

CORRIDOR

TOUCH DOWN (OFA09)

CORRIDOR

CONSULT (EXRG3)

IMAGING RM

1021 - B

MAMMOGRAPHY SUITE

1021 - A

DRESSING

STAFF RADIOLOGY

1021 - A

TLT

0074-EE

STORAGE

0074-FF

STAIR

CONSULT

M. TLT. (TNPG1)

LOUNGE

TECH. RM.

STAIR

S097

VESTIBULE

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL SANITARY WASTE & VENT PIPING, RAIN LEADER & OVERFLOW

DRAIN PIPING IS ABOVE CEILING. UNLESS NOTED OTHERWISE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

1.

2.

3.

KEYED NOTES

PROVIDE FUTURE CAPPED SANITARY WASTE & VENT

CONNECTIONS ABOVE CEILING.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING FIRST FLOOR PLAN

- WASTE & VENT

PL102

HAS SLC

1/8" = 1'-0"1

PLUMBING FIRST FLOOR PLAN - WASTE & VENT

6BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

BB

CC

D D

E E

AA

A.AA.A

P-418

P-528

P-935

P-418

3" DCW UP

2" DHW UP

1" DHWR UP

1" DCWR UP

P-801

P-801

P-801

P-609

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

VALVED PUMP

BY-PASS

P-418

2" DCW

1" DCWR

P-520

P-113

P-524

P-701P-113

P-420P-528

P-528

P-528

P-910

P-111

P-420

P-502

3"DCW SERVICE FROM

BELOW SLAB.

P-528 P-528 P-528 P-528 P-528

P-935

P-910

P-528

P-524

P-708

P-111

P-111

DCW

DCW

DCWR

DHWR

DHW

DCW

D H W

D H W

1" DHW

1" DHW

2" DCW

3" DCW

1" DCWR

1" DHWR

2" DHW

3" DCW

1/2" DCW1/2" DHW

DOMESTIC BOOSTER PUMP SYSTEM

DBP-1. SEE SCHEDULE SHT. PP602

AND DETAIL 1, SHT. PP502.

DUAL BACKFLOW PREVENTERS BFP-1

SEE DETAIL 1, SHT. PP501.

P-809 P-809 P-809 P-809 P-809

3/4" DCW

STEAM INSTANTANEOUS

WATER HEATERS SWH-1

& SWH-2. SEE SCHEDULE

SHT. PP602. SEE DETAIL

9, SHT. PP501.

THERMOSTATIC MIXING

VALVE TMV-1. SEE

SCHEDULE SHT. PP602.

SEE DETAIL 8, SHT. PP501.

CIRCULATING PUMP RCP-2

3/4" DCW

P-812

3"DCW SERVICE BELOW GRADE.

SEE CIVIL DRWGS. FOR

CONTINUATION.

1" DCW

1" DCW

1" DCW

3/4" DCW 3/4" DCW

3/4" DCW

P-420

P-420

2" DCW

3" DCW

2 1/2" DCW

3" DCW

3" DCW

BB

CC

D D

E E

AA

A.AA.A

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

5.8

5.8

A.4A.4

1.9

1.9

2.6

2.6

4.1

4.1

1.95

1.95

1.2

1.2

6.9

6.9

A.0A.0

C.9C.9

1" DCWR

P505

D C W

DCW DCW

1/2" DHW

3/4" DCW

3/4" DHWR

3/4" DHW 3/4" DCW

1 1/4" DCW

3/4" DHW

3/4" DCW

1" DHW

1" DCW

1" DHW

1" DCW

1" DHW

1" DCW

1" DHW

1 1/4" DCW

1 1/2" DCW

3/4" DHW

3/4" DCW

3/4" DHW

1 1/4" DCW

1" DHW

1 1/2" DCW

1" DHW

2" DCW

ICEMAKER

1 1/4" DHW

2" DCW

1 1/4" DHW

1 1/2" DHW

2" DCW

2" DCW

1 1/2" DHW

1 1/2" DHW

3/4" DCW

1 1/2" DHW

2" DCW

1 1/2" DHW

2" DCW2" DCW

1 1/2" DHW

DHW

DCW DCW

DHW DHW

DCW

DHW

DCW

DHW

DCW

DHW

DCW

DHW

DCW

DHW

DCW

DHW

DHWDHW

DCW

D H W R

D C W

D H W R

D C W R

D H W R

D C W R

D H W D C W

3/4" DCWR

BALANCING VALVES

BALANCING VALVES

CIRCULATING PUMP RCP-1

1" DCW

1" DCW

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL WATER PIPING IS ABOVE CEILING. UNLESS NOTED OTHERWISE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

1.

2.

3.

KEYED NOTES

INSTALL BALANCING VALVES ON THE DOMESTIC HOT WATER

RETURN AND DOMESTIC COLD WATER RETURN.

PROVIDE REDUCED PRESSURE BACKFLOW PREVENTERS FOR

SUPPLY AND RETURN DIALYSIS BOX FEED WATER. PROVIDE

FUNNEL FOR BACKFLOW PREVENTERS AND PIPE DISCHARGE TO

MOP BASIN.

VALVE AND CAP 2"DCW, 1-1/2"DHW, 3/4"DHWR & 3/4"DCWR

FOR FUTURE ABOVE CEILING.

1" DCW WITH REDUCED PRESSURE BACKFLOW PREVENTER FOR

MECHANICAL EQUIPMENT MAKE-UP WATER CONNECTION. SEE

MECHANICAL DRWGS. FOR CONTINUATION.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING BASEMENT PLAN -

WATER

PP101

HAS SLC

1/8" = 1'-0"1

PLUMBING BASEMENT PLAN - WATER

7BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

BB

CC

D D

E E

AA

A.AA.A

3" DCW DN

2" DHW DN

1" DHWR DN

1" DCWR DN

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

P-418

P-418

P-418

P-418

P-420 P-111

P-111

P-420

P-111

P-111

P-111

P-111

P-502

P-420

P-111P-418P-418P-418P-418

P-418 P-418

1 1/4" DHW 1 1/2" DCW

1 1/4" DHW

1 1/4" DHW

3" DCW

2" DHW

1" DHWR

3/4" DCWR

3/4" DHWR

1 1/2" DHW

2" DCW

1/2" DHW

3/4" DCWR

1 1/4" DHW

1 1/4" DCW1/2" DHW

1" DCW

1/2" DHW

1/2" DCW

P-524

P-204

P-420 P-420 P-420

P-420 P-420 P-420

P-812P-812

BB

CC

D D

E E

AA

A.AA.A

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

5.8

5.8

A.4A.4

1.9

1.9

2.6

2.6

4.1

4.1

1.95

1.95

1.2

1.2

6.9

6.9

A.0A.0

C.9C.9

DHWR

DCWR

DCWDCW

DHW

DCW

DHW

DHW

DCW DCWR

DHW

DHW DHW

DCW

DHW

DCW

DHW

DCW

D C W

D H W

D C W

D H W

D C W

D H W

D H W

D C W

D H W

D C W

D H W

D C W

D H W

D C W

D H W

D C W

1 1/4" DHW

2" DCW

1 1/2" DCW

2" DCW

1 1/4" DHW

1/2" DHW

1" DCW

1/2" DCW

1 1/4" DCW

1 1/4" DHW

1/2" DCW

1/2" DHW

1/2" DCW

1/2" DHW

1/2" DCW

1" DHW

1 1/4" DCW

1" DHW

3/4" DHWR

1/2" DCW

1"DCW DN.

1" DCW

3/4" DHW

1 1/4" DCW

1 1/4" DHW

1" DHW 1" DCW

1/2" DCW

1/2" DHW

1/2" DHW 1/2" DCW

1" DHW

1" DCW

3/4" DCWR 3/4" DHWR

1/2" DCW

1/2" DHW

1 1/2" DHW 2" DCW

1/2" DHW

1/2" DCW 1 1/2" DHW

2" DCW

1/2" DCW

1/2" DHW

1/2" DCW

1/2" DHW

1 1/4" DHW

2" DCW

1" DCW

2" DCW

1 1/4" DHW

1-1/2"DCW

DN.

2"DCW DN.

2" DCW

2" DCW

1 1/4" DHW

1/2" DHW

1/2" DHW

3/4" DCWR1/2" DCW

1/2" DCW

1/2" DHW

1/2" DHW 1/2" DCW

3/4" DHW

1" DHW

1"HW DN.

P-111

OPEN OFFICE AREA

(OFA09)

CONSULT (EXRG3)

TOUCH DOWN (OFA09)

CONSULT (EXRG3)

CONSULT (EXRG3)

TOUCH DOWN (OFA09)

WORK (NSTA1)

IT

STORAGE (SRE01)

ELEV. VESTIBULE

CLINICAL ELEVATOR

RECEP. (RCED1)

ELECTRICAL

CONSULT (EXRG3)

CONSULT (EXRG3)

CONSULT (EXRG3)

S. TLT (TNPG1)

CORRIDOR

TOUCH DOWN (OFA09)

CONSULT (EXRG3)

TOUCH DOWN (OFA09)

CONSULT (EXRG3)

HAC (JANC1)

TOUCH DOWN (OFA09)

WM. TLT. (TNPG1)

TLT (TNPG1)

EQUIP (SRE01)

WAITING AREA (WTG20)

CORRIDOR

CONSULT (EXRG3)

STORAGE (SRE01)

CONSULT (EXRG3)

CORRIDOR

CORRIDOR

ALCOVE

TLT (TPG01)

BREAK/LOCKERS

(SLO01)

CORRIDOR

CORRIDOR

CORRIDOR

TOUCH DOWN (OFA09)

CORRIDOR

CONSULT (EXRG3)

1021 - B

MAMMOGRAPHY SUITE

1021 - A

DRESSING

0074-EE

STORAGE

0074-FF

STAIR

CONSULT

M. TLT. (TNPG1)

LOUNGE

TECH. RM.

STAIR

S097

VESTIBULE

KEYED NOTES

PROVIDE FUTURE CAPPED WATER CONNECTIONS ABOVE

CEILING, 3"DCW, 2"DHW, 1"DHWR, 1"DCWR. PROVIDE GATE

VALVES WITH PROVISIONS TO DRAIN PIPE FROM VALVE TO

CAPPED CONNECTION.

PROVIDE BALANCING VALVES.

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL WATER PIPING IS ABOVE CEILING. UNLESS NOTED OTHERWISE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

1.

2.

3.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING FIRST FLOOR PLAN

- WATER

PP102

HAS SLC

1/8" = 1'-0"1

PLUMBING FIRST FLOOR PLAN - WATER

8BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

ZV-1

1" MA

1/2" N2O

2" VAC,1/2" N2O,

1" MA & 1" O2 UP

1/2" N2O 1" O2

1" MA

PIPING ROUTED

IN CRAWLSPACE.

VERIFY ROUTING

AAP-1

1 1/2" VAC

2" VAC

1 1/2" VAC

MGH-2

MGH-3

2" VAC,1" MA, 1" O2,

& 1/2" N2O DOWN IN

PIT THRU FOUNDATION

WALL TO CRAWLSPACE.

1" MA

1" O2

1/2" N2O

2" VAC

MGH-2

VAC

N2O

O2

MA

VAC

O2

MA

O2

N2O

VAC

VAC

O2

MA

MA

O2

VAC

MA

O2

VAC

V A C

O

M A

O

V A C

V A C

M A

O

V A C

M A

O

V A C

MGH-2

MGH-2

MGH-2

ZV-2

1/2" O2

1/2" MA

1" VAC

1" VAC

1/2" O2

1/2" MA

3/4" VAC

1/2" O2

1/2" MA

1/2" MA

1 1/4" VAC

3/4"VAC, 1/2"O2

& 1/2"MA (TYPICAL) 1/2" O2

3/4" VAC

1" VAC

1" VAC

1/2" MA

1/2" O2

1 1/4" VAC

1/2" O2

1/2" MA

1 1/4" VAC

3/4" O2

3/4" MA

3/4" O2

3/4" MA

3/4" VAC

1/2" O2

3/4" VAC

1/2" O2

1/2" O2

3/4" VAC

O2

VAC

M A

O

3"VAC EXH.

RISE.

1/2" MA

1/2" O2

3/4" VAC

MEDICAL VACUUM PUMP MVP-1.

SEE SCHEDULE SHT. PP602 AND

DETAIL SHT. PP501.

VAC

MA

O2

BALL VALVE

(TYPICAL)

SEE ZONE VALVE

BOX DETAIL 2

SHT. PP501 (TYP.)

SEE WALL OUTLET

DETAIL 5, SHT. PP501

AAP-1

MGH-1 MGH-1 MGH-1 MGH-1

MGH-2

MG-1MG-1

MATCHLINE 'A-A'

3"VAC EXH.

1/2" MA

1/2" O2

3/4" VACMA

O2

N2O

VAC

V A C

N 2O

O

M A

V A C

N 2O

O

M A

V A C

M A

N 2O

O

V A C

2" VAC

BB

CC

D D

E E

AA

1 6

A.AA.A

B.6B.6

D.3 D.3

3.1

3.1

A.A.2A.A.2 4.1

4.1

3.9

3.9

4.3

4.3

E.1E.1

A.4A.4

1.9

1.9

2.6

2.6

C.9C.9 e7 e8 e9 eA2eB e6

5.8

5.8

1.95

1.95

6.9

A.0A.0

1.2

1.2

1/2" N2O 1" O2

1" MA

PIPING ROUTED

IN CRAWLSPACE.

VERIFY ROUTING

1 1/2" VAC

(E)MEDICAL

VACUUM

PUMP

(E)MEDICAL AIR

COMPRESSOR

(E)AIR DRYER

(E)LAB AIR

COMPRESSOR

(E)WATER

HEATER

(E)WATER

HEATER

(E)1/2" LA

(E)1" NIT

(E)1" N2O

(E)1 1/2" MV

(E)1" LV

(E)1" MA

(E)1/2" MA

(E)1/2" LA

(E)1/2" LV

(E)1/2" MA

(E)1/2" NG

(E)1" LV

(E)1 1/2" MV

(E)1" O2

(E)1" NG

(E)1" O2

(E)1 1/2" MV

(E)1" O2

(E)1" NG

PIPING IN

CRAWLSPACE

(E)1 1/2" MV, 1" O2

& 1" NG UP & DN

IN WALL

ABOVE CEILING

ABOVE CEILING

ABOVE CEILING

PIPING TO DENTAL

SERVICE AREA

1" MA UP

1 1/2" VAC UP

1 1/2" VAC

1" MA

1/2" N2O

1" O2

1/2" N2O UP

MATCHLINE 'A-A'

V A C

N 2O

O

M A

V A C

N 2O

O

M A

V A C

N

N 2O

O 2 V A C

V A C

N

N 2O

O

N 2O

O

N 2O

O2

VAC

O2

V A C

O

M A

A.AA.A

A.A.1A.A.1

1.9

1.9 eAeA2eB e6 e5 eA1 e4

1.95

1.95

1.2

1.2

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL MEDICAL GAS IS ABOVE CEILING. UNLESS NOTED OTHERWISE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

1.

2.

3.

KEYED NOTES

ROUTE MEDICAL GAS PIPING IN CRAWLSPACE. CONNECT TO

EXISTING MEDICAL AIR COMPRESSOR, VACUUM PUMP, OXYGEN

PIPING AND NITROUS OXIDE MANIFOLD PIPING TO SERVE NEW

ADDITION.

CONNECT TO EXISTING MEDICAL AIR COMPRESSOR PIPING.

VERIFY LOCATION.

CONNECT TO EXISTING MEDICAL VACUUM PIPING. CONNECTION

TO EXISTING VACUUM PUMP IS FOR REDUNDANT BACKUP.

VERIFY LOCATION.

CONNECT TO EXISTING OXYGEN PIPING IN CRAWLSPACE. VERIFY

LOCATION OF EXISTING VALVE TO SHUTDOWN OXYGEN PIPING

TO MAKE CONNECTION.

CONNECT TO EXISTING NITROUS OXIDE PIPING. VERIFY

LOCATION.

CONNECT ALARM SIGNAL FROM NEW VACUUM PUMP TO

EXISTING MASTER ALARM PANEL. VERIFY EXISTING PANEL HAS

ADDITIONAL

SENSOR MODULES FOR CONNECTION OF NEW ALARM SIGNAL.

ADD ADDITIONAL SENSOR MODULE IF REQUIRED.

LOCKABLE VALVES ABOVE CEILING.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING BASEMENT PLAN -

MEDICAL GAS

PP103

HAS SLC

1/8" = 1'-0"1

PLUMBING BASEMENT PLAN - MEDICAL GAS

1/8" = 1'-0"2

PLUMBING CRAWL SPACE PLAN - MEDICAL GAS

9BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

2" VAC DN

1/2" N2O DN

1" MA & O2 DN

3" VAC EXHAUST

DN

3" VAC EXHAUST

UP THRU ROOF

2"VAC, 1/2"N2O, 1"MA

& 1"O2 VALVED AND

CAPPED FOR FUTURE.

BB

CC

D D

E E

AA

1 6

A.AA.A

B.6B.6

D.3 D.3

3.1

3.1

A.A.1A.A.1

A.A.2A.A.2 4.1

4.1

3.9

3.9

4.3

4.3

A.4A.4

1.9

1.9

2.6

2.6

C.9C.9 e7 e8 e9 eA2eB e6

5.8

5.8

1.95

1.95

6.9

A.0A.0

1.2

1.2

GENERAL NOTES

PLUMBING CONTRACTOR SHALL COMMUNICATE AND COORDINATE

WITH OWNER ANY SHUT DOWN OF EXISTING SYSTEMS OR SPACES

IN WRITING AND RECEIVE APPOVAL A MINIMUM OF SEVEN (7) DAYS

PRIOR TO EVENT.

ALL MEDICAL GAS IS ABOVE CEILING. UNLESS NOTED OTHERWISE.

PLUMBING CONTRACTOR SHALL MAKE PROVISIONS TO PROVIDE UTLITIES

TO KEEP AREAS OUTSIDE OF THE SCOPE OF WORK OPERATIONAL AS

REQUIRED.

1.

2.

3.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING FIRST FLOOR PLAN

- MEDICAL GAS

PP104

HAS SLC

1/8" = 1'-0"1

PLUMBING FIRST FLOOR PLAN - MEDICAL GAS

10BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

BB

CC

D D

E E

AA

A.AA.A

6" RD-1

(2736 SQ. FT) 6" OD-1

(2736 SQ. FT)

6" RD-1

(2502 SQ. FT)

6" OD-1

(2502 SQ. FT)

6" RD-1

(2769 SQ. FT) 8" OD-1

(2769 SQ. FT)

6" OD-1

(1931 SQ. FT)

6" RD-1

(1931 SQ. FT)

4" RD-1

(1609 SQ. FT)

6" OD-1

(1609 SQ. FT)

2" VAC EXHAUST

THRU ROOF

4" VTR

4" VTR

4" VTR

4" OD-1

(1877 SQ. FT)

4" RD-1

(1877 SQ. FT)

B.6B.6

D.3 D.3

C.3C.3

3.1

3.1

4" RD-1

(703 SQ. FT)

4" OD-1

(703 SQ. FT)

3" VTR

6" RD-1

(1634 SQ. FT)

4" RD-1

(1060 SQ. FT)

6" OD-1

(1060 SQ. FT)

6" OD-1

(1634 SQ. FT)

COORDINATE PLUMBING VENTS TO MAINTAIN

REQUIRED DISTANCES FROM OUTSIDE AIR

INTAKES ON ROOFTOP HVAC UNITS.

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135PLUMBING ROOF PLAN

PP105

HAS SLC

1/8" = 1'-0"1

PLUMBING ROOF PLAN

11BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

2" V

4" W

2" V

2" W

2" V

3" V

3" V

1 1/2" V

2" W

2" V

2" W

2" W 4" W

2" V

2" V

4" W

4" W

4" W

4" W

2" W

2" V

2" V

4" W

3" V

P-935

P-910

P-502

P-420

P-111

4" W

4" W

4" W3" V

2" V

2" V

2" V

2" V

2" W

3" V

4" W

2" W

3" V

2" V

4" W

2" W

2" V

2" V

4" W

2" V

2" V

2" W

3" V

2" V 2" W

2" V

4" W 3" V

3" V

2" W

3" W

4" W

3" W

3" W

3" W

2" W

4" W

2" W

2" V

3" V

6" W

4" W

3" W 4" W

2" V

P-910

P-935

P-528

P-528

P-528

P-528

P-528

P-520

P-528

P-502

P-420

P-113

2" V

P-528

FCO

P-809

P-809

P-809

P-809

P-809

6'W. BELOW GRADE

SEE CIVIL DRWGS. FOR

CONTINUATION.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

3"FD-E

W/T.P.

4"HD

W/T.P.

4" W

4" W

3" W

3" W

3" W

4" W

4" W

3" W

4" W

6" W

4" W

3" V

2" V

2" W

3" V

2" V

P-420

P-111

P-609

P-420

2" V

3"V. RISER

4"W. RISER

2" W

4" W

2" V

4" W

3" W

2" W

3" W

3"FCO

4"FCO

2" W

4" W

3" V

2" V

2" W

4" W

4"FCO

P-524

P-528

P-528

P-420 P-113

4"FCO

P-528

P-505

P-708

P-708

2" V

3" V

2" V

2" V P-528

2" V

4"W. RISER

3"V. RISER

2" V

4" W

2" W

4" W2" W

2" W

2" V

4" W

4" W

4"FCO

3"V. RISER

4"W. RISER

P-528

P-418

2" W

4"FCO

2" V

2" V

2" V

4" W

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135SANITARY RISER DIAGRAM

BASEMENT FLOOR

PP301

HAS SLC

SANITARY RISER DIAGRAM BASEMENT FLR.

12BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

2" V

2" W

4" W

3" W

4" W

3" W

2" V

3" V

2" V

4" W

3" V

2" V

2" W

2" W

4" W

3" V

2" V

3" V

2" V

4" W

2" W

2" W

3" V

2" V

2" W

3" V

4" W

3" V

2" V

P-418

P-418

P-420

P-111

P-418

P-111

P-204 P-502

P-111

P-420

P-420

P-111

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-420

P-420

P-420

P-111

P-111

P-111

P-111

2" V

2" V

3" V

2" W

2" W

3"V. FROM BELOW

3"VTR

3" V

3" W

2" V

P-418

2" W

4" W

2" W

2" V

3" V

3" V

2" V

3" V

4"W. RISER DN.

3"V. RISER

4"VTR

2" V

2" V

4" W

3" V

2" V

2" W

2" V

4" W

4" W

4" W

2" V

3" V

3"FD-C

W/T.P.

3"FD-C

W/T.P.

4" W

2" V

2" V 3" V

2" V

3" V

3" W

2" W

2" W

2" W

2" V

2" V

2" W

3" W

3" W

2" V

2" W

2" W

2" V

2" W

2" W

2" W

4" W

2" W

2" V

2" V

2" V

4"W. RISER DN.

3"V. RISER

4"VTR4" W

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY SSSSPPPPRRRRIIIINNNNKKKKLLLLEEEERRRREEEEDDDD

07/07/2020

Atriax, pllc

102 3RD AVENUE, NE

PO BOX 1629

HICKORY, NC 28603

PHONE: 828.315.9962

FAX: 828.315.9964

8845 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.523.2230

FAX: 704.523.2235

www.freemanwhite.com

215 PARK AVE SE

AIKEN, SC 29801

TELEPHONE: 803.502.0657

FAX: 803.643.4648

www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254

Office of Construction and Facilities Management

O N

E O

N E

O N

E O

N E

E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T E

IG

H

O

T O

N E

O N

E O

N E

O N

E

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

Q U

A R

T

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

E

IG

H

T

O T

E

IG

H T

O

T E

IG

H

T

O T

E

IG

H T

O

T O

N E

O N

E O

N E

O N

E

H A

O

T H

A

O T

H A

O

T H

A

O T

T H

R E

E T

H R

E E

T H

R E

E T

H R

E E

Q

U A

R T

E

O T

Q U

A R

T E

O

T Q

U A

R T

E

O T

Q U

A R

T E

O

T O

O

T O

O

T O

O

T O

O

T O

E

O

E O

E

O

E

H A

H

O

T H

A

H

O T

H A

H

O

T H

A

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

T H

R

H

O T

00 00 44 44

88 88

00 00

44 44 88 88

A

B

C

D

E

F

8701 RED OAK BLVD.

CHARLOTTE, NC 28217-5593

TELEPHONE: 704.522.0495

FAX: 704.522.0499

www.lrspc.net

LAURENE, RICKHER

& SORRELL, P.C.

Consulting Structural Engineers

LeGrand Engineering, Inc. VAMC FAYETTEVILLE, NC

A

B

C

D

E

F

565-135SANITARY RISER DIAGRAM

FIRST FLOOR

PP302

HAS SLC

NTS

SANITARY RISER DIAGRAM FIRST FLR.

13BYBYBYBY REVISIONSREVISIONSREVISIONSREVISIONS DATEDATEDATEDATE

3" DCW

2" DHW

1" DHWR

1" DCWR

2" DCW

1 1/2" DHW

3/4" DHWR

3/4" DCWR

1/2" DCW

1" DHW

1" DCW

3/4" DCW

1" DCW

1/2" DCW

1/2" DCW

1/2" DHW

3" DCW

3/4" DCW

1/2" DHW

P-935

P-910

P-502P-420

P-111

P-935

P-528

P-528

P-528

P-528

P-528

P-528

P-502

P-113

P-418

P-809

P-809

P-801

P-809

P-809

3/4" DCW P-809

3/4" DCW

3/4" DCW

3/4" DCW

3/4" DCW

3/4" DCW

1" REDUCED PRESSURE

BACKFLOW PREVENTERS

FOR DIALYSIS BOX DCW

SUPPLY.

P-708

1/2" DHW

1/2" DCW

P-418

ICEMAKER

P-524

1/2" DCW

1/2" DHW

1/2" DCW

P-910

P-801

P-910

1" DCW

P-524

P-812

1/2" DCW

1/2" DCW

1/2" DHW

RISE TO 1ST FLR.

3" DCW

2" DHW

1" DHWR

1" DCWR

P-528

P-528 1/2" DCW

1/2" DHW

1/2" DCW

1/2" DHW

P-520

1/2" DHW

1/2" DCW

1/2" DCW

1/2" DHW

2" DCW

P-420P-505

P-528

1/2" DHW

1/2" DCW

1/2" DHW

3/4" DCW

P-113

P-418

P-528

3/4" DCW

1/2" DCW

1/2" DHW

1/2" DHW

1/2" DCW

2"DCW, 1-1/2"DHW,

3/4"DHWR & 3/4"DCWR

VALVED AND CAPPED

FOR FUTURE.

3"DCW SERVICE BELOW

GRADE.

RISE UP FROM BELOW SLAB

IN MECH. RM. WITH BALL VALVE.

P-801

P-420

P-609

P-111

P-111

P-420

1/2" DHW

1/2" DCW

1 1/2" DCW

1/2" DCW

3" DCW

DUAL REDUCED PRESSURE

BACKFLOW PREVENTERS.

SEE DETAIL 1, SHEET PP501.

P-701

INSTANTANEOUS STEAM

WATER HEATERS SWH-1 &

SWH-2. SEE DETAIL 9, SHEET

PP501.

DOMESTIC WATER BOOSTER

PUMP SYSTEM. SEE DETAIL 1

PP502.

3" DCW

3" DCW3" DCW

3" DCW2" DHW

2" DCW

1" DCW

1"HVAC MAKE-UP WITH

REDUCED PRESSURE

BACKFLOW PREVENTER.

SEE MECH. DRWGS. FOR

CONTINUATION.

3" DCW

2" DHW

1" DCWR

1/2" DCW

1/2" DHW

3" DCW

3" DCW

3" DCW

2" DCW

1 1/2" DHW

1" DCWR

2" DCW

1 1/2" DHW

1/2" DHW

1/2" DCW

1 1/2" DHW

2" DCW

1 1/2" DHW

2" DCW

1" DCW

1/2" DHW

1/2" DCW

1/2" DHW

1/2" DCW

1 1/2" DHW

2" DCW

2" DCW

1 1/2" DHW

1 1/2" DHW

2" DCW

1 1/2" DHW

1/2" DHW

1/2" DCW

3/4" DCW

1 1/2" DCW

1 1/4" DCW

1" DHW

1/2" DHW

1/2" DCW

1/2" DHW

1/2" DCW

3/4" DCW

3/4" DCW

3/4" DCW

3/4" DCW

3/4" DCW

3/4" DCW

1" DCW

3/4" DCW

3/4" DCW

3/4" DCW

1" DCW

1/2" DCW

1/2" DHW

1/2" DHW

1" DCW

1" DHW

1" DCW

1/2" DHW

1/2" DCW

1/2" DHW

1" DHW

1" DHW

1" DCW

3/4" DHW

3/4" DCW

3/4" DHW

3/4" DCW

3/4" DHWR

3/4" DCW

1" DCWR

1" DHWR

3/4" DHW

3/4" DCWR

3/4" DCW

BALANCING VALVE

BALANCING VALVE

3/4" DCWR

1" DCW

3/4" DCWR

1/2" DCW

1/2" DHW

1/2" DCW

1/2" DHW

1" DCW

1" DCW 1" DCW

1/2" DCW

3/4" DCW3/4" DHW

1 1/4" DCW

1" DHW

1 1/2" DCW

1 1/4" DCW

1/2" DHW

1" DHW

2" DCW

1 1/4" DHW

2" DCW

1/2" DCW

1 1/4" DHW

2" DCW

DDDDeeeeppppaaaarrrrttttmmmmeeeennnntttt ooooffff

VVVVeeeetttteeeerrrraaaannnnssss AAAAffffffffaaaaiiiirrrrssss

1 2 3 4 5 6 7 8 9

Project TitleProject TitleProject TitleProject Title Project Number

Building Number

Drawing Number of

Location

EXPAND BUILDING 1 D-WING

1 2 3 4 5 6 7 8 9

CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: SEAL:SEAL:SEAL:SEAL: ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:ARCHITECT/ENGINEERS:

Drawing Title

Approved Project Director:

Date: Checked: Drawn:

Dwg.

FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS FINAL SUBMISSION: CONSTRUCTION DOCUMENTS ---- FFFFUUUULLLLLLLLYYYY…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .