20210511_19-080_Rev 1_ A-002.pdf

PDF 196 KB Posted

Attached to
Y1DA--Renovate Building 3 for PACT and FCA Deficiencies (VA-20-00088636)
Solicitation number
36C24621R0041
Issued by

About this file

This document includes a presolicitation notice and description for a federal contract opportunity to renovate Building 3 at the W.G. Bill Hefner VA Medical Center in Salisbury, North Carolina. The renovation work includes providing all labor, materials, equipment, permits, supervision, and completing all work in accordance with contract drawings and specifications. The period of performance is 729 calendar days from notice to proceed. The estimated construction cost is between $5 million and $10 million. This opportunity is set aside for Service Disabled Veteran Owned Small Businesses. Bidding documents will be available on March 1, 2021, with proposals due 30 days after solicitation issuance. The solicitation will be posted at the provided website. Interested vendors should register and monitor the site for amendments. Offerors must register in SAM and VetBiz with current, active registrations to be eligible for award. ORCA also applies. The point of contact is provided for site visit coordination and questions, though no phone requests for bid documents will be accepted. The place of performance and contracting office contact information is included.

View the file

Other files

File Type Posted
2019 Salisbury VAMC Asbestos Survey.pdf PDF
36C24621R0041 0002.docx DOCX document
36C24621R0041 0002.pdf PDF
36C24621R0041 0001.pdf PDF
Bldg.3 Pact Sign in Sheet_2021.pdf PDF
36C24621R0041 0001.docx DOCX document
Attachment A - Itemized Schedule of Values Cost Breakdown.xlsx XLSX spreadsheet
Combined Specs.pdf PDF
36C24621R0041.docx DOCX document
Combined Drawings.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

*FIRESTOP ALL

PENETRATIONS

WALL PRIORITY PLAN & LEGEND

SCALE: 1-1/2"=1'-0"

-H

R R

A T

E D

W A

L L

NON-

RATED

WALL

RATED WALL

N O

N

R A

T E

D

W A

L L

1-HR

RATED

WALL

2-HR

RATED

WALL

1-HR

RATED

WALL

TWO (2) LAYER

OF TYPE "X"

GYP. BD. AT

2-HR AND 1-HR

RATED WALL

INTERSECTION

HOLLOW METAL

FRAME

JAMB STUDS AS

REQUIRED

HIGHER PRIORITY

WALL

METAL STUDS AS

PRESCRIBED IN

WALL SCHEDULE

2" M

A X

2" MAX.

PROVIDE 2" GAP

BETWEEN TOP OF

VERTICAL STUDS @ TOP

OF STUD TRACK

BREAK METAL

CLOSURE ANGLE,

PAINT (WHERE TOP

OF WALL IS

EXPOSED)

CONT. CAULK BEAD

@ CLOSURE ANGLE

3" SLIP TRACK STUD

TRACK ANCHORED TO

BOTTOM OF ROOF

DECK. VERTICAL

STUDS ARE NOT TO BE

ANCHORED TO TRACK

REFER TO PARTITION

TYPES FOR WALL

SHEATHING MATERIAL

3 5/8" SOUND

ATTENUATION

INSULATION

SLIP TRACK DETAIL FOR DEFLECTION

SCALE: 3"=1'-0"

CEILING

STEEL STUDS

(3 5/8") (UNO)

@ 16" OC

GYP WALL BD (5/8")

FLOOR SLAB

SEALANT

*SEAL ALL

PENETRATIONS

WITH SEALANT

PARTITION TYPE 1

SCALE: 1-1/2"=1'-0"

2.0 SIMILAR

WITH 2 1/2" STUDS

4.0 SIMILAR

WITH 4" STUDS

1.0 SIMILAR

WITH 1 5/8" STUDS

6.0 SIMILAR

WITH 6" STUDS

SOUND

ATTENUATION

INSULATION

BASE AS

SCHEDULED

EXTEND STUDS TO

STRUCTURE AND

SECURE W/ SLIP TRACK

UNDERSIDE OF

FLOOR OR ROOF

ASSEMBLY

STC-49

CEILING

STEEL STUDS

(3 5/8") (UNO)

GYP WALL BD (5/8")

FLOOR SLAB

SEALANT

*SEAL ALL

PENETRATIONS

WITH SEALANT

PARTITION TYPE 3

SCALE: 1-1/2"=1'-0"

EXTEND STUDS TO

STRUCTURE AND

SECURE

BASE AS SCHEDULED

SEALANT

FLOOR SLAB

GYP WALL

BOARD (5/8")

STEEL STUDS

(2 1/2") (UNO)

CEILING

UNDERSIDE OF

STRUCTURE

SEALANT

PARTITION TYPE 2

SCALE: 1-1/2"=1'-0"

*SEAL ALL

PENETRATIONS

WITH SEALANT

BASE AS

SCHEDULED

EXTEND

STUDS TO

STRUCTURE

AND SECURE

X.XXX

FUNCTION

FUNCTION (CHASE, SMOKE, SOUND)

FIRE RATING

STUD SIZE

CEILING

7/8" STL. FURRING.

@16" O.C.

GYP WALL BD (5/8")

FLOOR SLAB

SEALANT

*SEAL ALL

PENETRATIONS

WITH SEALANT

PARTITION TYPE 4

SCALE: 1-1/2"=1'-0"

/8

BASE AS SCHEDULED

EXIST.

CONST.

EXIST.

CONST.

CEILING

STEEL STUDS

(6") (UNO)

MOISTURE RESISTANT GYP

WALL BD (5/8")

FLOOR SLAB

SEALANT

*SEAL ALL

PENETRATIONS

WITH SEALANT

PARTITION TYPE 5

SCALE: 1-1/2"=1'-0"

EXTEND STUDS TO

STRUCTURE AND

SECURE

BASE AS SCHEDULED

Engineers Architects

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:2

:4

A

M

A-002

PARTITION TYPES AND DETAILS

2 20

PAUL D. LORENZ

EJD

Renovate B3 for PACT and FCA Deficiencies

1601 Brenner Avenue Salisbury, NC 28144

October 6, 2020

CONSTRUCTION DOCUMENTS

659-18-10319-080

JAB

A. REFER TO LIFE SAFETY PLAN FOR RATED WALL

LOCATIONS.

B. UL WALL DESIGNATIONS TO BE USED TO DEFINE

NEW RATED WALL ASSEMBLIES. IN CASE OF

EXISTING RATED WALLS, CONFIRM DESIGN

IMPROVEMENTS TO EXISTING ASSEMBLY MEETS UL

STANDARDS FOR RATED WALL ASSEMBLIES.

C. PROVIDE 5/8" GLASS MAT EXTERIOR GRADE

GYPSUM BOARD IN LIEU GYPSUM BOARD AT ALL

WET WALLS LOCATIONS, WALLS WITH PLUMBING

FIXTURES.

D. PROVIDE 5/8" TYPE "X" GYPSUM WALL BOARD FOR

ALL OTHER WALL CONSTRUCTION, UNO.

E. PROVIDE CORNER AND END WALL FRAMING AS

DETAILED.

F. FASTEN BRACING @ 4'-0" MAX OF TO STRUCTURAL

DECK OR STEEL ABOVE WITH BENT TRACK AND TWO

FASTENERS.

G. ALL MECHANICAL SHAFTS SHALL BE FIRE-RATED

CONSTRUCTION AS SHOWN ON PLAN.

H. REFER TO FLOOR PLANS SHEET FOR FIRE RATED

AND SMOKE PARTITION LOCATIONS. ALL FIRE AND

SMOKE PARTITIONS SHALL EXTEND FROM FLOOR

SLAB TO THE UNDERSIDE OF STRUCTURE - DECK

ABOVE. ALL PENETRATIONS SHALL BE SEALED AND

PROTECTED WITH FIRE RATED SEALANT TO

MAINTAIN THE INTEGRITY OF THE PARTITION.

I. PARTITION INSTALLATION SHALL CONFORM TO

APPLICABLE CODE REQUIREMENTS.

J. WHERE PARTITIONS OF DIFFERENT FIRE RATING

INTERSECT, PARTITION WITH THE HIGHEST FIRE

RATING SHALL BE CONTINUOUS PER FOLLOWING

PRIORITY LIST:

PRIORITY 1: TWO HOUR FIRE AND SMOKE WALL

PRIORITY 2: TWO HOUR FIRE OR SHAFT WALL

PRIORITY 3: ONE HOUR FIRE AND SMOKE WALL

PRIORITY 4: ONE HOUR FIRE WALL

PRIORITY 5: NON-RATED WALL

PROVIDE IDENTIFICATION OF ALL FIRE RATED

AND/OR SMOKE PARTITIONS AT NOT MORE THAN

10'-0" ON CENTER ABOVE CEILINGS WITH 3" HIGH

STENCILED BLOCK LETTERING AS FOLLOWS: "1

HOUR FIRE", "1 HOUR FIRE/SMOKE", "2 HOUR FIRE",

"2 HOUR FIRE/SMOKE", "2 HOUR SHAFT", ETC.

K. EXTEND FIRE RATED WALL CONSTRUCTION BEHIND

RECESSED OR BUILT-IN EQUIPMENT SUCH AS FIRE

EXTINGUISHER CABINETS (FEC), ELECTRICAL WATER

COOLERS (EWC), ELECTRICAL PANELS, ETC.

L. STAGGER GYPSUM BOARD JOINTS VERTICALLY AND

HORIZONTALLY A MINIMUM OF 16" EACH SIDE OF

PARTITION AT ALL PARTITIONS.

M. PROVIDE TYPE 'X' WATER RESISTANT GYPSUM WALL

BOARD ON ALL SURFACES IN ALL TOILETS,

BREAKROOM, PROVIDE TYPE 'X' TILE

BACKERBOARD ON ANY PARTITION SCHEDULED TO

BE FINISHED WITH TILE WORK.

N. ALL VERTICAL PIPING AND COLUMNS EXPOSED IN

ROOMS SHALL BE FURRED WITH METAL STUDS AND

GWB AND FINISHED TO MATCH ADJACENT WALLS,

UNO

O. WHERE HVAC OR OTHER MECHANICAL , ELECTRICAL

AND PLUMBING ITEMS PENETRATE PARTITIONS,

STUDS SHALL BE BRACED AND FRAMED TO

STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE

SUPPORT. ALL PENETRATIONS THROUGH RATED

WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE,

AND/OR ACOUSTICAL ISOLATION OF SPACES,WITH

APPROPRIATE FIRE STOP MATERIAL.

P. COORDINATE METAL STUD GAUGE WITH PRE-

APPROVED EQUIPMENT ANCHORAGE. WHERE

DISCREPANCY OCCURS, THE MORE STRINGENT

REQUIREMENT SHALL GOVERN.

Q. PROVIDE FIRE SAFE INSULATION AS REQUIRED TO

MAINTAIN THE INTEGRITY OF FIRE RATED

PARTITIONS.

R. PROVIDE REQUIRED FRAMES AND BRACING

AROUND WALL PENETRATIONS.

S. PROVIDE CONTINUOUS ACOUSTICAL SEALANT AT

BOTTOM OF ALL PARTITIONS.

T. WHERE COLUMN FURRING STUDS EXCEED THE

MANUFACTURER'S RECOMMENDED LIMITING

HEIGHTS, STUDS SHALL BE BRACED BACK TO THE

STRUCTURE AS REQUIRED.

U. SEE WALL TYPES AND FLOOR PLANS FOR SOUND

ATTENUATION BLANKETS LOCATION.

V. THERE SHALL BE NO BACK-TO-BACK ELECTRICAL,

TELEPHONE, OR OTHER OUTLETS, EXCEPT WHERE

SPECIFICALLY SHOWN.

W. ALL PARTITIONS SHALL MEET STC 40 (MIN.)

X. AFTER REMOVING EXISTING SOLID CONCRETE

MASONRY WALL, FILL FLOOR VOIDS UP TO FINISH

CONCRETE LEVEL AND PERFORM FLOOR LEVELING

FOR ENTIRE RENOVATION.

PARTITION DESIGNATION

SHEET NOTES

1 Addendum 1 05/10/2021

NOTE: CONTRACTOR TO PROVIDE MOISTURE

RESISTANT GYPSUM BOARD IN ALL RESTROOMS AND

WET AREAS.

Sheets
A-002 - PARTITION TYPES AND DETAILS