36C24619R0087-0002003.pdf

PDF 576 KB Posted

Attached to
Project 659-18-106, Install Exhaust Hoods Buildings 8 and 42
Solicitation number
36C24619R0087
Issued by

About this file

36C24619R0087 0002 3 - AE-101 REV1.pdf

View the file

Other files

File Type Posted
36C24619R0087-0005003.pdf PDF
36C24619R0087-0005000.docx DOCX document
36C24619R0087-0005002.pdf PDF
36C24619R0087-0005001.pdf PDF
36C24619R0087-0004000.docx DOCX document
36C24619R0087-0004001.pdf PDF
36C24619R0087-0003000.docx DOCX document
36C24619R0087-0002001.pdf PDF
36C24619R0087-0002004.pdf PDF
36C24619R0087-0002005.pdf PDF
36C24619R0087-0002006.pdf PDF
36C24619R0087-0002000.docx DOCX document
36C24619R0087-0002002.pdf PDF
36C24619R0087-0001000.docx DOCX document
36C24619R0087-0001001.pdf PDF
36C24619R0087-010.docx DOCX document
36C24619R0087-008.pdf PDF
36C24619R0087-012.docx DOCX document
36C24619R0087-007.docx DOCX document
36C24619R0087-009.pdf PDF
36C24619R0087-011.pdf PDF
36C24619R0087-006.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3 3 3

HOOD

HOOD

SD

SD

SIM.

HOOD

SD

HOOD

SD

LOCATION OF HOOD SHOWN IS TENTATIVE. CONTRACTOR TO NOTIFY COR PRIOR TO BID IF

LOCATION SHOWN PRESENTS A CONFLICT.

SEE HOOD AND EXHAUST FAN DRAWINGS IN THIS SET. CAPTIVE AIRE IS THE BASIS OF DESIGN -

ACCUREX IS AN ADDITIONAL APPROVED SYSTEM. NO OTHER MANUFACTURES ARE ACCEPTABLE.

LIGHT FIXTURE, SMOKE/FIRE DETECTOR, SPRINKLER HEAD IF REQUIRED TO PLACE HOOD.

NEW SYSTEM TO BE POWERED AND WIRED FROM A HOUSE PANEL. CONTRACTOR TO PROVIDE

NEW BREAKERS SUITABLE FOR PANEL. BIDDERS TO VERIFY/CONFIRM AVAILABILITY OF AN

OPEN/AVAILABLE CIRCUIT WITHIN NEAREST HOUSE PANEL.

GENERAL NOTES

REMOVE EXIST. ROLL-UP DOOR ACCESS PANEL. PROVIDE/INSTALL NEW 24"X24" ACCESS

PANEL UNDER BULKHEAD. FRAME OPENING W/ LT. GA. MTL..

REMOVE AND RELOCATE EXISTING LIGHT FIXTURE/SMOKE DETECTOR/ SPRINKLER HEAD/

DIFFUSER/ETC. AS NEEDED TO ACCOMMODATE NEW HOOD.

REMOVE SECTIONS OF EXIST. SUSPENDED CEILING TO ACCOMMODATE HOOD. REPLACE/

MODIFY CEILING GRID/TILE TO FIT TIGHT AROUND HOOD WITH NO GAPS OR UNEVENNESS.

36" WIDE, 22 GA. BRUSHED S.S. WALL PANEL. RUN FROM BASE TO HOOD. TREAT ALL

EXPOSED EDGES W/ S.S. CAP OR MOLDING.

PLACE EXHAUST HOOD AS CLOSELY TO SOFFIT AS POSSIBLE.

WALLS, FINISHES, CEILING TILE, CEILING GRID DISTURBED, DAMAGED OR DIRTIED DURING

DEMO OR DEMOLITION MUST BE MADE LIKE NEW.

FROM 2ND FLOOR UP THROUGH TO ROOF - DOUBLE WALL, 2HR. RATED EXHAUST DUCT TO

ROOF FAN. ADJUST LOCATION OF DUCT AS NEEDED TO ACCOMMODATE STRUCTURE. SEE

HOOD/FAN DRAWINGS. BIDDER TO CONFIRM BUILD-ABILITY PRIOR TO SUBMITTING BID.

NEW FINISHED PARTITION WALL:

" GWB ON EACH SIDE OF 3-5/8" MTL. STUDS

TO 4" +/- ABOVE EXIST. CEILING. TAPE AND FINISH READY FOR PAINT. A LEVEL 4 FINISH IS

REQUIRED FOR NEW OR REPAINTED SURFACES.

CHASE: 3-5/8" 22 GA. METAL SUDS FROM FLOOR TO DECK. COVER W/

" GWB. TAPE AND

FINISH FOR PAINT. LEVEL 4 FINISH IS REQUIRED.

PROVIDE & INSTALL STEEL FOR CONCRETE OPENINGS. SEE DETAIL ON SHEET AE-101.

SD

EXISTING LIGHT FIXTURE

EXISTING SMOKE/FIRE DETECTOR

LEGEND

PLAN NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

A

F i l e

P a t h

P

M

BID DOCUMENTSOffice of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Paul Lorenz, AIA Salisbury VA

BLDG. 42 & 8

KITCHEN EXHAUST HOODS

Salisbury VA

659-18-106

BLDG. 42/8

Project Director

1.7.19 - PDLRevisions: Date:

#1 - BIDDING RFI 4.3.19

NTS

BLDG. 8 FIRST FLOOR PARTIAL PLAN

"=1'-0

ENLARGED PLAN-SIM. ALL FLOORS

BLDG. 8 PLANS, NOTES, DETAILS

AE-101

NTS

BLDG. 8 SECOND FLOOR PARTIAL PLAN

NTS

BLDG. 8 THIRD FLOOR KITCHEN PLAN