36C24619R0033-004.pdf
PDF 16 MB Posted
- Solicitation number
- 36C24619R0033
About this file
36C24619R0033 Drawings-Final - Copy.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24619R0033-0003000.docx | DOCX document | |
| 36C24619R0033-0003001.pdf | ||
| 36C24619R0033-0002003.pdf | ||
| 36C24619R0033-0002002.pdf | ||
| 36C24619R0033-0002004.pdf | ||
| 36C24619R0033-0002000.docx | DOCX document | |
| 36C24619R0033-0002001.pdf | ||
| 36C24619R0033-0001000.docx | DOCX document | |
| 36C24619R0033-001.docx | DOCX document | |
| 36C24619R0033-002.xlsx | XLSX spreadsheet | |
| 36C24619R0033-003.pdf | ||
| 36C24619R0033-000.docx | DOCX document | |
| 36C24619R0033.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DURHAM VA MEDICAL CENTER
DURHAM, NORTH CAROLINA
UPGRADE OUTSIDE AIR AND EXHAUST FANS PART TWO
BUILDING #1 PROJECT NO. 558-15-152
"CONFIDENTIAL"
INDEX OF DRAWINGS
FINAL SUBMISSION - FOR BIDDING PURPOSES ONLY
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
RALEIGH | 919.816.2907
3737 GLENWOOD AVENUE, SUITE 100, 27612
NC License No: C-2848 AME Project No: 15105
15o
85p
501o
FU
LT
O N
S
T.VA MEDICAL
CENTER
S L
A S
A
LL
E S
T.
70o
BUS
SPRUNT AVE.
N L
A S
A
LL
E S
T.
H
IL
LA
N
D A
LE
R
D
70o
BUS
ERWIN RD.
AutoCAD SHX Text THESE DRAWINGS MUST BE RETURNED TO MUST BE RETURNED TO BE RETURNED TO FACILITIES MANAGEMENT SERVICE, PROJECT SECTION, UPON COMPLETION, OR FINAL USE BY THE CONTRACTOR FOR BIDDING PURPOSES.
AutoCAD SHX Text
COVER SHEET - PROJECT LOCATION AND DRAWING INDEX
AutoCAD SHX Text
AutoCAD SHX Text
GI001
AutoCAD SHX Text
DWG.#
AutoCAD SHX Text
SHEET #
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
DWG.#
AutoCAD SHX Text
SHEET #
AutoCAD SHX Text M-001
AutoCAD SHX Text
MECHANICAL - GENERAL NOTES AND LEGEND
AutoCAD SHX Text M-201
AutoCAD SHX Text
MECHANICAL - SPS DECONTAMINATION AREA FLOOR PLAN - NEW WORK
AutoCAD SHX Text M-202
AutoCAD SHX Text
MECHANICAL - ELEVATOR TOWER ROOF PLAN - NEW WORK
AutoCAD SHX Text M-601
AutoCAD SHX Text
MECHANICAL - SCHEDULES
AutoCAD SHX Text M-701
AutoCAD SHX Text
MECHANICAL - SCHEMATIC
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text 102 THIRD AVENUE NE HICKORY, NC 28601 PHONE: 828.315.9962 FAX: 828.315.99664 NC ENGINEERING LICENSE NO: P-0214 NC ARCHITECTURE LICENSE NO: 51254
AutoCAD SHX Text
CAMPUS MAP
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text M-203
AutoCAD SHX Text M-204
AutoCAD SHX Text
MECHANICAL - F WING ROOF PLAN - NEW WORK
AutoCAD SHX Text
MECHANICAL - AHU-16 EQUIP. ROOM PLANS - DEMOLITION AND NEW WORK
AutoCAD SHX Text
AREA MAP
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GI002
AutoCAD SHX Text
GROUPING PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
GI004
AutoCAD SHX Text
SITE OVERVIEW AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text M-101
AutoCAD SHX Text
MECHANICAL - SPS DECONTAMINATION AREA FLOOR PLAN - DEMOLITION
AutoCAD SHX Text
AutoCAD SHX Text M-102
AutoCAD SHX Text
MECHANICAL - ELEVATOR TOWER ROOF PLAN - DEMOLITION
AutoCAD SHX Text
AutoCAD SHX Text M-103
AutoCAD SHX Text
MECHANICAL - F WING ROOF PLAN - DEMOLITION
AutoCAD SHX Text
AutoCAD SHX Text M-602
AutoCAD SHX Text
MECHANICAL - SCHEDULES
AutoCAD SHX Text
AutoCAD SHX Text M-603
AutoCAD SHX Text
MECHANICAL - CONTROL DIAGRAMS HVAC
AutoCAD SHX Text
AutoCAD SHX Text M-702
AutoCAD SHX Text
MECHANICAL - DETAILS
AutoCAD SHX Text
AutoCAD SHX Text E-001
AutoCAD SHX Text
ELECTRICAL - GENERAL NOTES AND LEGENDS
AutoCAD SHX Text
AutoCAD SHX Text E-101
AutoCAD SHX Text
ELECTRICAL - SPS DECONTAMINATION AREA FLOOR PLAN - DEMOLITION
AutoCAD SHX Text
AutoCAD SHX Text E-102
AutoCAD SHX Text
ELECTRICAL - ELEVATOR TOWER ROOF PLAN - DEMOLITION
AutoCAD SHX Text
AutoCAD SHX Text E-103
AutoCAD SHX Text
ELECTRICAL - F WING ROOF PLAN - DEMOLITION
AutoCAD SHX Text
AutoCAD SHX Text E-201
AutoCAD SHX Text
ELECTRICAL - SPS DECONTAMINATION AREA FLOOR PLAN - NEW WORK
AutoCAD SHX Text
AutoCAD SHX Text E-202
AutoCAD SHX Text
ELECTRICAL - ELEVATOR TOWER ROOF PLAN - NEW WORK
AutoCAD SHX Text E-203
AutoCAD SHX Text
ELECTRICAL - F WING ROOF PLAN - NEW WORK
AutoCAD SHX Text E-204
AutoCAD SHX Text
ELECTRICAL - AHU-16 EQUIP. ROOM PLANS - DEMOLITION AND NEW WORK
AutoCAD SHX Text E-501
AutoCAD SHX Text
ELECTRICAL - RISERS AND SCHEDULES
AutoCAD SHX Text E-601
AutoCAD SHX Text
ELECTRICAL - FIRE ALARM RISER AND DETAILS
AutoCAD SHX Text
AutoCAD SHX Text A-101
AutoCAD SHX Text
ARCHITECTURAL - DEMOLITION AND CONSTRUCTION PLAN
AutoCAD SHX Text
AutoCAD SHX Text
GI003
AutoCAD SHX Text
EQUIPMENT WORK SCHEDULE
AutoCAD SHX Text 558-15-152
AutoCAD SHX Text
AutoCAD SHX Text Durham VAMC
AutoCAD SHX Text Durham
AutoCAD SHX Text
NC
AutoCAD SHX Text
UPGRADE OUTSIDE AIR
AutoCAD SHX Text
AND EXHAUST FANS
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
COVER SHEET, PROJECT LOCATION
AutoCAD SHX Text and DRAWING INDEX
AutoCAD SHX Text
GI001
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text plb
AutoCAD SHX Text
EHH
AutoCAD SHX Text
AUGUST 31, 2018
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Approved:
AutoCAD SHX Text Date:
AutoCAD SHX Text Electrical Shop Supervisor
AutoCAD SHX Text Name
AutoCAD SHX Text Medical Center Director
AutoCAD SHX Text Name
AutoCAD SHX Text Contract Officer
AutoCAD SHX Text Name
AutoCAD SHX Text Associate Director
AutoCAD SHX Text Name
AutoCAD SHX Text M & O
AutoCAD SHX Text Name
AutoCAD SHX Text FMS Chief
AutoCAD SHX Text Name
AutoCAD SHX Text Safety Manager
AutoCAD SHX Text Name
AutoCAD SHX Text Energy Engineer
AutoCAD SHX Text Name
AutoCAD SHX Text Infection Control
AutoCAD SHX Text Name
AutoCAD SHX Text Project Supervisor
AutoCAD SHX Text Name
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
MRI
AutoCAD SHX Text
BOOTH
AutoCAD SHX Text I.C.U.
AutoCAD SHX Text
FULTON STREET
AutoCAD SHX Text
ERWIN ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FINAL SUBMISSION - FOR BIDDING PURPOSES ONLY
CHARLOTTE | 704.295.4263
705 EAST MOREHEAD STREET, 28202
RALEIGH | 919.816.2907
3737 GLENWOOD AVENUE, SUITE 100, 27612
NC License No: C-2848 AME Project No: 15105
GENERAL
1. Contractor is responsible for becoming familiar with the work and all areas of the existing building affected by the work, carefully verifying all dimensions, and bringing any discrepancies to the immediate attention of the COR.
2. Contractor will include information describing how he will comply with ICRA requirements in the narrative.
3. Contractor will obtain a permit prior to beginning work above ceilings.
4. Contractor must obtain hot work permits daily for welding, soldering, torch cutting, and burning 24 hours prior to the start of work from the COR. Fire watch is required. Contractor will furnish fire extinguishers. Contractor must acquire and hold these permits at the work site at all times.
5. No smoking except in designated areas outside of building as defined in Specifications Section 01 00 00.
6. Contractor shall protect the existing facility and repair any damage resulting from the work.
7. Contractor will notify the COR seven days prior to any core drilling.
8. Contractor will provide three weeks notice in writing prior the shut down of any utility.
9. Contractor will notify the COR of any damaged fire sprinkler components and repair immediately.
10. Contractor will legally remove and dispose of all debris.
PROTECTION COORDINATION & REQUIREMENTS
1. Contractor shall maintain all site areas in a safe condition at all times.
2. Contractor is responsible for providing protection for building, systems, occupants, and pedestrians at all times during construction.
3. Contractor shall submit safety plan to COR for review indicating all safety measures to be implemented during construction.
4. Contractor is responsible for providing safe working conditions for all workers and facility users per OSHA requirements.
MECHANICAL SYSTEMS
1. Contractor shall protect Mechanical Units including Air Handlers, Compressors, and Piping as necessary, and Contractor shall maintain air flow (Intake & Exhaust) at equipment at all times. Intakes adjacent to work areas shall be filtered from dust and debris with minimum MERV13 filter cloth.
POWER
1. COR will determine availability of power supply (if any) at the time of the award of the construction contract.
2. If the VA is unable to provide a temporary electrical connection during construction, the Contractor will be required to provide electricity to support the work. Contractor will request an area to use the generator at least seven (7) calendar days prior to use. Contractor is responsible for protecting outside building air intakes from exhaust for the duration of the project.
3, Contractor shall provide power tree and tie-in to power source locations.
4. Contractor shall request power shutdowns of equipment through COR. Contractor shall not shutdown equipment or engage with VA breakers or disconnects on active equipment.
ACCESS AND MATERIAL STAGING
1. Roof access will be coordinated with the COR.
2. Exhaust from fans on could cause health risk to workers. Contractor shall coordinate access for replacement of these fans with COR at least fourteen (14) calendar days prior to beginning work. Contractor must receive a safety clearance from the COR each day prior to beginning work. Contractor must notify COR immediately when work is complete.
3. COR will determine availability of access and staging areas and identify potential locations (if any) at the time of the award of the construction contract. Area for staging or storage may not be available to the Contractor during construction.
4. Storage is not permitted around AHU intakes.
5. All hoist movements must take place after hours or on weekends.
6. Contractor shall plan staging and storage areas to minimize impact to existing infrastructure and allow for access to existing equipment.
7. Contractor shall include requests for access and staging areas in the narrative and schedule. See sheets GI003 and GI004 for more details.
SECURITY REQUIREMENTS
1. Roof access points / doors shall be kept locked at all times to prevent unauthorized persons from entering roof or mechanical rooms / stairs leading to roof. Doors shall not be propped open.
2. All material and equipment shall be kept in a secured state at all times.
3. Exterior storage areas shall be secured and kept locked at all times except when adding or removing materials.
4. Contractor shall supply temporary guard rails on rooftop where guard rails are not already installed as required.
MEDICAL CENTER OPERATIONS
1. Building areas will be occupied at all times. Contractor will schedule the work to minimize disruption to patient comfort and medical center operations.
2. Sheet GI003 and Sheet GI004 includes operation details and restrictions as a basis for schedule.
3. Contractor shall provide a schedule that projects the work for two weeks each week for COR approval throughout the duration of the project. Contractor should include staging/storage area and temporary power requests in the schedule information.
WORK AREA PREPARATION & PROTECTION
1. Contractor most provide walk-off mats and any other methods of protection needed during the construction/repair process, in order to protect stairwells from dirt and debris.
2. Contractor must protect areaway drains by cleaning and sweeping daily.
3. Contractor must install filters over roof drains to prevent debris from entering roof drain. Remove debris from roofs on a daily basis.
4. Contractor shall provide walk mats at roof surfaces where construction traffic and debris will affect existing roof.
5. All protection measures most be approved by COR prior to start of work.
6. Reference Specification Section 01.35.26, Subsection 1.2, for Infection Control Risk Assessment procedures.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
MRI
AutoCAD SHX Text
BOOTH
AutoCAD SHX Text I.C.U.
AutoCAD SHX Text
FULTON STREET
AutoCAD SHX Text
ERWIN ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text 102 THIRD AVENUE NE HICKORY, NC 28601 PHONE: 828.315.9962 FAX: 828.315.99664 NC ENGINEERING LICENSE NO: P-0214 NC ARCHITECTURE LICENSE NO: 51254
AutoCAD SHX Text 558-15-152
AutoCAD SHX Text
AutoCAD SHX Text Durham VAMC
AutoCAD SHX Text Durham
AutoCAD SHX Text
NC
AutoCAD SHX Text
UPGRADE OUTSIDE AIR
AutoCAD SHX Text
AND EXHAUST FANS
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
SITE OVERVIEW AND NOTES
AutoCAD SHX Text
GI002
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text plb
AutoCAD SHX Text
EHH
AutoCAD SHX Text
AUGUST 31, 2018
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SITE OVERVIEW
AutoCAD SHX Text
NORTH
705 EAST MOREHEAD STREET, 28202
RALEIGH | 919.816.2907
3737 GLENWOOD AVENUE, SUITE 100, 27612
NC License No: C-2848 AME Project No: 15105
NOTES
This project was originally broken into two parts. Part One was previously constructed under a separate contract. Part Two is subdivided into multiple groups based on replacement priority and order through the construction duration.
Contractor shall submit a bid for PART TWO of this project ONLY.
Sheet GI003 Grouping Plan and Sheet GI004 Equipment Work Schedule detail priority, order, equipment offline times and durations, etc., and Contractor will base the project schedule and narrative on this information.
No equipment shall be offline more than three days except as described on GI004.
Contractor shall notify the VA COR in writing of any conflicts or unforeseen conditions.
Project includes removal and replacement of exhaust fans for F Wing and equipment replacement and removal for the Elevator Tower divided into seven Groups as shown on Sheet GI004 Equipment Work Schedule, and Groups are determined by priority and what the fan serves.
AutoCAD SHX Text
EQUIPMENT ROOF PLAN
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text 558-15-152
AutoCAD SHX Text
AutoCAD SHX Text Durham VAMC
AutoCAD SHX Text Durham
AutoCAD SHX Text
NC
AutoCAD SHX Text
UPGRADE OUTSIDE AIR
AutoCAD SHX Text
AND EXHAUST FANS
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
GROUPING PLAN
AutoCAD SHX Text
GI003
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MEM
AutoCAD SHX Text
EHH
AutoCAD SHX Text
AUGUST 31, 2018
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text 102 THIRD AVENUE NE HICKORY, NC 28601 PHONE: 828.315.9962 FAX: 828.315.99664 NC ENGINEERING LICENSE NO: P-0214 NC ARCHITECTURE LICENSE NO: 51254
AutoCAD SHX Text
F WING
AutoCAD SHX Text
E WING
AutoCAD SHX Text
ATRIUM
AutoCAD SHX Text
A WING EXT.
AutoCAD SHX Text
B WING
AutoCAD SHX Text
A WING
AutoCAD SHX Text
D WING
AutoCAD SHX Text
ELEVATOR TOWER
AutoCAD SHX Text
B WING EXT.
AutoCAD SHX Text
B WING EXT.
AutoCAD SHX Text
AB WING
AutoCAD SHX Text
C WING
AutoCAD SHX Text
ICU TOWER
AutoCAD SHX Text
PENTHOUSE
AutoCAD SHX Text
PART ONE
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
PART ONE
AutoCAD SHX Text
PART ONE
AutoCAD SHX Text
EF-21
AutoCAD SHX Text
EF-18
AutoCAD SHX Text
EF-19
AutoCAD SHX Text
EF-20
AutoCAD SHX Text
EF-17
AutoCAD SHX Text
EF-15
AutoCAD SHX Text
EF-16
AutoCAD SHX Text
EF-14
AutoCAD SHX Text
EF-22
AutoCAD SHX Text
EF-11
AutoCAD SHX Text
EF-9
AutoCAD SHX Text
EF-12
AutoCAD SHX Text
EF-7
AutoCAD SHX Text
EF-10
AutoCAD SHX Text
EF-42
AutoCAD SHX Text
EF-6
AutoCAD SHX Text
EF-13
AutoCAD SHX Text
EF-4
AutoCAD SHX Text
EF-5
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
EF-ET-2
AutoCAD SHX Text
EF-ET-1
AutoCAD SHX Text
EF-ET-3
AutoCAD SHX Text
EF-F-TB
AutoCAD SHX Text
EF-NEW
AutoCAD SHX Text
EF-46
AutoCAD SHX Text
EF-36
AutoCAD SHX Text
EF-ED2
AutoCAD SHX Text
EF-47
AutoCAD SHX Text
EF-43
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
EF-F-B
EF-HW-555
705 EAST MOREHEAD STREET, 28202
RALEIGH | 919.816.2907
3737 GLENWOOD AVENUE, SUITE 100, 27612
NC License No: C-2848 AME Project No: 15105
GENERAL NOTES
1. Exhaust from some fans on F WING roof could cause health risk to workers. Contractor shall coordinate access for replacement of these fans with VAMC Contracting Officer Representative (COR) at least seven (7) calendar days prior to replacing this equipment. Contractor must receive a safety clearance from the VAMC COR each day prior to beginning work in these areas. Contractor must notify VAMC COR immediately when work is complete for each piece of equipment.
GROUP 1 - F WING
1. Work hours for this group are not restricted.
2. Contractor will complete all work to replace Group 1 - F Wing exhaust fans including testing and balancing prior to beginning Group 2 - F Wing.
GROUP 2 - F WING, GROUP 3 - F WING, GROUP 4 - F WING, GROUP 5 - F WING
1. Contractor will replace the equipment in these groups at night and on weekends only.
2. Contractor will complete all work to replace or remove exhaust fans in each group including testing and balancing prior to beginning the next group.
GROUP 6 - F WING
1. Contractor may begin the Work for Group 6 after Groups 1 through 5 are complete including testing and balancing.
2. Contractor will replace the equipment in this group on weekends only with the exception of EF-47 AND EF-ED2. Contractor to co-ordinate with VA-COR replacement times for EF-47 &
EF-ED2.
3. EF-47 and EF-ED2 may be offline concurrently. Contractor may work continuous shifts to replace these fans.
GROUP 7 - ELEVATOR TOWER
1. Work hours for this group are not restricted.
2. Contractor may begin the Work for Group 7 after Group 1 is complete including testing and balancing.
EQUIPMENT WORK SCHEDULE
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text 102 THIRD AVENUE NE HICKORY, NC 28601 PHONE: 828.315.9962 FAX: 828.315.99664 NC ENGINEERING LICENSE NO: P-0214 NC ARCHITECTURE LICENSE NO: 51254
AutoCAD SHX Text 558-15-152
AutoCAD SHX Text
AutoCAD SHX Text Durham VAMC
AutoCAD SHX Text Durham
AutoCAD SHX Text
NC
AutoCAD SHX Text
UPGRADE OUTSIDE AIR
AutoCAD SHX Text
AND EXHAUST FANS
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
EQUIPMENT WORK SCHEDULE
AutoCAD SHX Text
AutoCAD SHX Text
GI004
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text plb
AutoCAD SHX Text
EHH
AutoCAD SHX Text
AUGUST 31, 2018
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3206
AutoCAD SHX Text
EF-7
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3183
AutoCAD SHX Text
EF-10
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3180
AutoCAD SHX Text
EF-42
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3175
AutoCAD SHX Text
EF-F-TB
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3176
AutoCAD SHX Text
EF-22
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3162A
AutoCAD SHX Text
EF-15
AutoCAD SHX Text
EF-16
AutoCAD SHX Text
EF-17
AutoCAD SHX Text
F WING
AutoCAD SHX Text
F WING
AutoCAD SHX Text
F WING
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3158A, F3158B, F3158C
AutoCAD SHX Text F3158
AutoCAD SHX Text F3158
AutoCAD SHX Text
EF-21
AutoCAD SHX Text
F WING
AutoCAD SHX Text F1111
AutoCAD SHX Text
EF-46
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3142
AutoCAD SHX Text
EF-NEW
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3141I
AutoCAD SHX Text
EF-43
AutoCAD SHX Text
A & F WINGS
AutoCAD SHX Text A3052, A3056, F3247
AutoCAD SHX Text
EF-36
AutoCAD SHX Text
F WING
AutoCAD SHX Text
RANGE HOOD
AutoCAD SHX Text
EF-HW-555
AutoCAD SHX Text
F WING
AutoCAD SHX Text
AutoCAD SHX Text
EF-18
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3224, F3226, F3227, F3230
AutoCAD SHX Text
EF-6
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3183
AutoCAD SHX Text
EF-11
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3176
AutoCAD SHX Text
EF-14
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3160
AutoCAD SHX Text
EF-12
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3157
AutoCAD SHX Text
EF-9
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3185
AutoCAD SHX Text
EF-13
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3157
AutoCAD SHX Text
EF-2
AutoCAD SHX Text
EF-4
AutoCAD SHX Text
F WING
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3203, F3205
AutoCAD SHX Text F3203A
AutoCAD SHX Text
EF-F-B
AutoCAD SHX Text
F WING
AutoCAD SHX Text
AutoCAD SHX Text
EF-3
AutoCAD SHX Text
EF-5
AutoCAD SHX Text
F WING
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3203
AutoCAD SHX Text F3203A
AutoCAD SHX Text
EF-20
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3236
AutoCAD SHX Text
EF-47
AutoCAD SHX Text
F WING
AutoCAD SHX Text
TRIAGE #1, #2
AutoCAD SHX Text
EF-ED2
AutoCAD SHX Text
F WING
AutoCAD SHX Text
AutoCAD SHX Text
PROJECT NOTES
AutoCAD SHX Text HISTOLOGY LAB, CSI/Jewett (3) hoods; Model JGP4-18; SN EE34527, 3RD FLOOR
AutoCAD SHX Text
MICROBIOLOGY LAB, GENERAL EXHAUST, 3RD FLOOR
AutoCAD SHX Text
LABORATORY, GENERAL EXHAUST, 3RD FLOOR
AutoCAD SHX Text
BLOOD BANK, GENERAL EXHAUST, 3RD FLOOR
AutoCAD SHX Text
MICROBACTERIA, GENERAL EXHAUST, 3RD FLOOR
AutoCAD SHX Text
OFFICES, 3RD FLOOR (FORMER LAB SPACE)
AutoCAD SHX Text
OFFICES, 3RD FLOOR (FORMER LAB SPACE)
AutoCAD SHX Text
OFFICES, 3RD FLOOR (FORMER LAB SPACE)
AutoCAD SHX Text
CONFERENCE ROOM, 1ST FLOOR
AutoCAD SHX Text
RADIOLOGY ROOM
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE, TOILETS, 3RD FLOOR
AutoCAD SHX Text
RANGE HOOD
AutoCAD SHX Text
AutoCAD SHX Text
CT SCAN/CAMERA
AutoCAD SHX Text
AutoCAD SHX Text MICROBIOLOGY LAB, Casework
AutoCAD SHX Text MICROBACTERIAL LAB, SterilGARD Class II Type A/B3
AutoCAD SHX Text LAB, (2) Siemens Dimension Vista 1500
AutoCAD SHX Text BIOHAZARD LAB, SterilGARD Class II Type A/B3
AutoCAD SHX Text LAB, Hamilton Safeaire
AutoCAD SHX Text MICROSCOPY LAB, Hamilton Safeaire Pelco 3470 Laboratory Microwave System
AutoCAD SHX Text MICROSCOPY LAB, Casework
AutoCAD SHX Text
CITOLOGY LAB, GENERAL EXHAUST
AutoCAD SHX Text CITOLOGY LAB, Ventana Symphony 32034
AutoCAD SHX Text RADIOACTIVE LAB, Labconco Protector Radioisotope Hood
AutoCAD SHX Text
EMERGENCY DEPARTMENT, 1ST FLOOR
AutoCAD SHX Text
OFFICES, 3RD FLOOR (FORMER LAB SPACE)
AutoCAD SHX Text
EMERGENCY DEPARTMENT, 1ST FLOOR
AutoCAD SHX Text
EF-19
AutoCAD SHX Text
F WING
AutoCAD SHX Text F3232
AutoCAD SHX Text RADIOACTIVE LAB, Labconco Protector Radioisotope Hood
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND CAP. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
PART ONE - COMPLETED
AutoCAD SHX Text
PART TWO -CURRENT CONTRACT
AutoCAD SHX Text
GROUP 1 - F WING
AutoCAD SHX Text
GROUP 3 - F WING
AutoCAD SHX Text
GROUP 4 - F WING
AutoCAD SHX Text
GROUP 5 - F WING
AutoCAD SHX Text
GROUP 6 - F WING
AutoCAD SHX Text
EQUIP #
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
SERVING
AutoCAD SHX Text
ACTION
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
ACID STORAGE, 3RD FLOOR
AutoCAD SHX Text
GROUP 2 - F WING
AutoCAD SHX Text
EF-ET-1
AutoCAD SHX Text
EF-ET-2
AutoCAD SHX Text
EF-ET-3
AutoCAD SHX Text
ELEVATOR TOWER
AutoCAD SHX Text
EQUIPMENT ROOM
AutoCAD SHX Text
AHU-16
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
GENERAL EXHAUST, ELEVATOR TOWER, MECHANICAL ROOM
AutoCAD SHX Text
GENERAL EXHAUST, ELEVATOR TOWER, MECHANICAL ROOM
AutoCAD SHX Text
GENERAL EXHAUST, ELEVATOR TOWER, MECHANICAL ROOM
AutoCAD SHX Text
ELEVATOR TOWER, ALL FLOORS
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE. SEE MECHANICAL PLANS FOR DETAILS.
AutoCAD SHX Text
REMOVE AND REPLACE WITH GRAVITY RELIEF HOOD AS SHOWN ON MECHANICAL PLANS.
AutoCAD SHX Text
GROUP 7 - ELEVATOR TOWER
AutoCAD SHX Text
ELEVATOR TOWER
AutoCAD SHX Text
ELEVATOR TOWER
AutoCAD SHX Text
ELEVATOR TOWER
AutoCAD SHX Text
EQUIPMENT ROOM
AutoCAD SHX Text
EQUIPMENT ROOM
AutoCAD SHX Text
ERV-1
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
ELEVATOR TOWER, ALL FLOORS
AutoCAD SHX Text
ADD. SEE MECHANICAL PLANS FOR DETAILS.
ELEVATOR TOWER
705 EAST MOREHEAD STREET, 28202
RALEIGH | 919.816.2907
3737 GLENWOOD AVENUE, SUITE 100, 27612
NC License No: C-2848 AME Project No: 15105
ARCHITECTURAL GENERAL DEMOLITION AND NEW WORK NOTES
ROOF
1. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS.
2. CONTRACTOR TO VERIFY ROOFING MATERIALS PRIOR TO REMOVAL OF ANY EQUIPMENT.
3. ALL NEW ROOFING MATERIALS ARE TO MATCH EXISTING ROOFING MATERIALS.
4. PROVIDE NEW SHEET METAL FLASHING WHERE REQUIRED.
5. SEE SHEET GI003 AND GI004 FOR ORDER AND GROUPING OF THE WORK. POWER SHUTDOWNS MUST BE REQUESTED THROUGH VA COR AND THE CONTRACTOR WILL NOTIFY THE VA COR OF ANY EQUIPMENT SHUT DOWN REQUESTS AT LEAST SEVEN (7) CALENDAR DAYS BEFORE ANY EQUIPMENT IS TAKEN OFFLINE. CONTRACTOR SHALL NOT SHUTDOWN EQUIPMENT OR ENGAGE WITH VA
BREAKERS OR DISCONNECTS ON EQUIPMENT.
6. WHERE A ROOF PENETRATION IS DISTURBED, CONTRACTOR WILL COMPLETE WORK THAT SAME DAY TO SEAL AND FLASH. NO ROOF AREA IS TO BE LEFT OPEN. IF WORK CANNOT BE COMPLETED WITHIN THE SAME DAY, CONTRACTOR MUST PROVIDE A TEMPORARY ROOF COVERING TO PROTECT INTERIOR SPACE. PLASTIC SHEETING IS NOT ACCEPTABLE. CONTRACTOR WILL SUBMIT A PLAN FOR TEMPORARY ROOF COVERING METHODS. CONTRACTOR WILL STORE MATERIALS ON SITE FOR EMERGENCY USE.
7. CONTRACTOR TO TAKE ALL REQUIRED MEASURES TO MAINTAIN VA ROOF WARRANTY.
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
NOT TO SCALE - FOR REFERENCE ONLY
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text 102 THIRD AVENUE NE HICKORY, NC 28601 PHONE: 828.315.9962 FAX: 828.315.99664 NC ENGINEERING LICENSE NO: P-0214 NC ARCHITECTURE LICENSE NO: 51254
AutoCAD SHX Text 558-15-152
AutoCAD SHX Text
AutoCAD SHX Text Durham VAMC
AutoCAD SHX Text Durham
AutoCAD SHX Text
NC
AutoCAD SHX Text
UPGRADE OUTSIDE AIR
AutoCAD SHX Text
AND EXHAUST FANS
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
ARCHITECTURAL REFERENCE PLANS
AutoCAD SHX Text
GENERAL DEMOLITION AND NEW WORK NOTES
AutoCAD SHX Text A101
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text plb
AutoCAD SHX Text
EHH
AutoCAD SHX Text
AUGUST 31, 2018
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
F WING
AutoCAD SHX Text
E WING
AutoCAD SHX Text
ATRIUM
AutoCAD SHX Text
A WING EXT.
AutoCAD SHX Text
B WING
AutoCAD SHX Text
A WING
AutoCAD SHX Text
D WING
AutoCAD SHX Text
ELEVATOR TOWER
AutoCAD SHX Text
B WING EXT.
AutoCAD SHX Text
B WING EXT.
AutoCAD SHX Text
AB WING
AutoCAD SHX Text
C WING
AutoCAD SHX Text
ICU TOWER
AutoCAD SHX Text
PENTHOUSE
AutoCAD SHX Text
PART ONE
AutoCAD SHX Text
PART ONE
AutoCAD SHX Text
PART TWO
AutoCAD SHX Text
PART ONE
AutoCAD SHX Text
PART ONE
PART TWO
705 EAST MOREHEAD STREET, 28202
RALEIGH | 919.816.2907
3737 GLENWOOD AVENUE, SUITE 100, 27612
NC License No: C-2848 AME Project No: 15105
AutoCAD SHX Text M-001
AutoCAD SHX Text
AutoCAD SHX Text
EL
AutoCAD SHX Text
MJM
AutoCAD SHX Text
MECHANICAL - GENERAL NOTES AND LEGEND
AutoCAD SHX Text
DESIGNATION
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
EXISTING TO REMAIN (EQUIPMENT, DUCTWORK, AIR DISTRIBUTION, ETC.)
AutoCAD SHX Text EXISTING TO BE DEMOLISHED OR RELOCATED - REFER TO PLAN OR RELOCATED - REFER TO PLAN RELOCATED - REFER TO PLAN NOTES PRIOR TO DEMOLITION (EQUIPMENT, DUCTWORK, AIR DISTRIBUTION, ETC.)
AutoCAD SHX Text
NEW (EQUIPMENT, DUCTWORK, AIR DISTRIBUTION, ETC.)
AutoCAD SHX Text
NEW/EXISTING/DEMO LEGEND
AutoCAD SHX Text
EXISTING TO REMAIN (PIPING)
AutoCAD SHX Text
NEW (PIPING)
AutoCAD SHX Text EXISTING TO BE DEMOLISHED OR RELOCATED - REFER TO PLAN OR RELOCATED - REFER TO PLAN RELOCATED - REFER TO PLAN NOTES PRIOR TO DEMOLITION (PIPING, CONTROL WIRING, ETC.)
AutoCAD SHX Text
BEGINNING OR END OF NEW WORK, OR DEMOLITION CONNECT TO EXISTING
AutoCAD SHX Text
CHILLED WATER SUPPLY
AutoCAD SHX Text
CHILLED WATER RETURN
AutoCAD SHX Text
CWR
AutoCAD SHX Text
HOT WATER SUPPLY (HEATING)
AutoCAD SHX Text
HOT WATER RETURN (HEATING)
AutoCAD SHX Text
CONDENSATE DRAIN PIPING
AutoCAD SHX Text
CD
AutoCAD SHX Text
3-WAY CONTROL VALVE
AutoCAD SHX Text
AUTOMATIC FLOW LIMITER VALVE
AutoCAD SHX Text
UNION
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
FULL PORT BALL VALVE
AutoCAD SHX Text
CONTROL VALVE
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
AF
AutoCAD SHX Text
BALANCING VALVE
AutoCAD SHX Text
RELATIVE HUMIDITY
AutoCAD SHX Text
RH
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
RA
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
PH
AutoCAD SHX Text
PRESSURE DROP
AutoCAD SHX Text
PD
AutoCAD SHX Text
OUTDOOR (VENTILATION) AIR
AutoCAD SHX Text
OA
AutoCAD SHX Text
MINIMUM CIRCUIT AMPACITY
AutoCAD SHX Text
MCA
AutoCAD SHX Text
MECHANICAL CONTRACTOR
AutoCAD SHX Text M.C.
AutoCAD SHX Text
1,000 BTU PER HOUR
AutoCAD SHX Text
MBH
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MAX
AutoCAD SHX Text
LEAVING AIR TEMPERATURE
AutoCAD SHX Text
LAT
AutoCAD SHX Text
DEGREES FAHRENHEIT
AutoCAD SHX Text °F
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text
EC
AutoCAD SHX Text
DRY BULB TEMPERATURE
AutoCAD SHX Text
DB
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
CFM
AutoCAD SHX Text
BUILDING AUTOMATION SYSTEM
AutoCAD SHX Text
BAS
AutoCAD SHX Text
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AutoCAD SHX Text
ASHRAE
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
NOISE CRITERIA
AutoCAD SHX Text
MAXIMUM OVER CURRENT PROTECTION
AutoCAD SHX Text
INCHES WATER GAUGE (PRESSURE)
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
FULL LOAD AMPS
AutoCAD SHX Text
FIRE DAMPER
AutoCAD SHX Text
SA
AutoCAD SHX Text
NC
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
EXTERNAL STATIC PRESSURE
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
IN. WG.
AutoCAD SHX Text H.P.
AutoCAD SHX Text
FLA
AutoCAD SHX Text
FD
AutoCAD SHX Text E.S.P.
AutoCAD SHX Text
AFF
AutoCAD SHX Text
AD
AutoCAD SHX Text
AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR CONDITIONING ENGINEERS
AutoCAD SHX Text
ASME
AutoCAD SHX Text
MECHANICAL ABBREVIATIONS
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
WET BULB TEMPERATURE
WB
AutoCAD SHX Text
SP
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DESIGNATION
AutoCAD SHX Text
ENTERING AIR TEMPERATURE
AutoCAD SHX Text
EAT
AutoCAD SHX Text
SENSIBLE
AutoCAD SHX Text
SENS
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text E.
AutoCAD SHX Text
EXISTING TO BE DEMOLISHED
AutoCAD SHX Text
ETBD
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
ETR
AutoCAD SHX Text
EXISTING TO BE RELOCATED
AutoCAD SHX Text
ETBR
AutoCAD SHX Text
DUCT SEALING REQUIREMENTS
AutoCAD SHX Text
1. SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, WALL PENETRATIONS, AND SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, WALL PENETRATIONS, AND DUCT CONNECTIONS. PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT, UNLESS IT HAS BEEN CERTIFIED TO COMPLY WITH UL-181A OR UL181B BY AN INDEPENDENT TESTING LABORATORY AND THE TAPE IS USED IN ACCORDANCE WITH THAT CERTIFICATION. 2. LONGITUDINAL SEAMS ARE JOINTS ORIENTED IN THE DIRECTION OF AIRFLOW. LONGITUDINAL SEAMS ARE JOINTS ORIENTED IN THE DIRECTION OF AIRFLOW. AIRFLOW. TRANSVERSE JOINTS ARE CONNECTIONS OF TWO DUCT SECTIONS ORIENTED PERPENDICULAR TO AIRFLOW. DUCT WALL PENETRATIONS ARE OPENINGS MADE BY ANY SCREW FASTENER, PIPE, ROD, OR WIRE. SPIRAL LOCK SEAMS IN ROUND DUCTS NEED NOT BE SEALED. ALL OTHER CONNECTIONS ARE CONSIDERED TRANSVERSE JOINTS, INCLUDING BUT NOT LIMITED TO SPIN-INS, TAPS AND OTHER BRANCH CONNECTIONS, ACCESS DOORS FRAMES AND JAMBS, DUCT CONNECTIONS TO EQUIPMENT, ETC.
AutoCAD SHX Text
AIRFLOW MEASUREMENT STATION
AutoCAD SHX Text
AMS
AutoCAD SHX Text
RAT
AutoCAD SHX Text
SMACNA
AutoCAD SHX Text
SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION
AutoCAD SHX Text
RETURN AIR TRANSFER (FRAMED OPENING ABOVE CEILING)
AutoCAD SHX Text
EXHAUST AIR (OR RELIEF AIR)
AutoCAD SHX Text
EA
AutoCAD SHX Text
ETHYLENE STERILIZATION OXIDE
AutoCAD SHX Text
ETO
AutoCAD SHX Text
TAB
AutoCAD SHX Text
TEST AND BALANCE
AutoCAD SHX Text
1. GENERAL NOTES ON THIS DRAWING ARE APPLICABLE TO EACH HVAC DRAWING OF THIS GENERAL NOTES ON THIS DRAWING ARE APPLICABLE TO EACH HVAC DRAWING OF THIS SET. SEE EACH DRAWING FOR SPECIFIC NOTES APPLICABLE TO THAT DRAWING. 2. MECHANICAL CONTRACTOR SHALL VISIT THE SITE TO CAREFULLY EXAMINE AND MECHANICAL CONTRACTOR SHALL VISIT THE SITE TO CAREFULLY EXAMINE AND FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS PRIOR TO BIDDING. SUBMISSION OF A PROPOSAL WILL BE CONSIDERED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN PERFORMED. CONTRACTORS BID SHALL INCLUDE ALL WORK NEEDING TO BE DONE AFTER HOURS, ON WEEKENDS, ANY WORK REQUIRING SHUTDOWNS, OR ANY TIME THAT MAY REQUIRE OVERTIME. LATER CLAIMS FOR EXTRA LABOR OR MATERIALS REQUIRED DUE TO DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. WILL NOT BE RECOGNIZED. 3. EXISTING CONDITIONS, EQUIPMENT, MATERIALS, AND SIZES ARE SHOWN FOR EXISTING CONDITIONS, EQUIPMENT, MATERIALS, AND SIZES ARE SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND BRING ANY DISCREPANCIES TO THE ENGINEER'S ATTENTION IN WRITING PRIOR TO DEMOLITION. 4. MECHANICAL CONTRACTOR SHALL REPAIR EXISTING BUILDING COMPONENTS DAMAGED MECHANICAL CONTRACTOR SHALL REPAIR EXISTING BUILDING COMPONENTS DAMAGED DURING HIS WORK ON SITE. IT IS THE RESPONSIBILITY OF M.C. TO MAINTAIN THE CONTINUITY OF THE EXISTING HVAC SYSTEMS DURING CONSTRUCTION. 5. MAINTAIN MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR ALL MECHANICAL MAINTAIN MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR ALL MECHANICAL EQUIPMENT. ALL EQUIPMENT MUST BE ACCESSIBLE FOR MAINTENANCE. 6. COORDINATE LOCATION AND INSTALLATION OF EQUIPMENT WITH OTHER TRADES. COORDINATE LOCATION AND INSTALLATION OF EQUIPMENT WITH OTHER TRADES. 7. PIPING, DUCTWORK, VENTS, ETC., EXTENDING THROUGH EXTERIOR WALLS AND ROOF PIPING, DUCTWORK, VENTS, ETC., EXTENDING THROUGH EXTERIOR WALLS AND ROOF SHALL BE FLASHED AND COUNTER FLASHED IN A WEATHERPROOF MANNER. 8. VALVES AND SPECIALTIES SHALL BE LINE SIZE EXCEPT FOR AUTOMATIC CONTROL VALVES AND SPECIALTIES SHALL BE LINE SIZE EXCEPT FOR AUTOMATIC CONTROL VALVES OR UNLESS NOTED OTHERWISE. AUTOMATIC CONTROL VALVES SCHEDULE SHALL BE SUBMITTED BY CONTROL CONTRACTOR TO ENGINEER FOR APPROVAL. 9. PIPING AND DUCTWORK INSULATION SHALL RUN CONTINUOUSLY THROUGH NON- PIPING AND DUCTWORK INSULATION SHALL RUN CONTINUOUSLY THROUGH NON- RATED FLOORS, WALLS, ROOF AND PARTITIONS, UNLESS OTHERWISE INDICATED. 10. NO PIPING SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED. NO PIPING SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED. 11. PROVIDE UNION OR FLANGED CONNECTIONS AT EACH PIECE OF EQUIPMENT AND ON PROVIDE UNION OR FLANGED CONNECTIONS AT EACH PIECE OF EQUIPMENT AND ON BOTH SIDES ON CONTROL VALVES AND PRESSURE REGULATING VALVES. PROVIDE SHUT-OFF VALVES ON BOTH SIDES OF AUTOMATIC VALVES. 12. PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE SPECIFICATIONS. ADDITIONAL PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE SPECIFICATIONS. ADDITIONAL SUPPORTS OR HANGERS SHALL BE ADJACENT TO ELBOWS, TO PREVENT WEIGHT OF PIPING BEING PLACED ON THE EQUIPMENT. 13. ALL LOW VOLTAGE WIRING, RELAYS, ETC., TO BE PROVIDED AND INSTALLED BY THE ALL LOW VOLTAGE WIRING, RELAYS, ETC., TO BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. 14. THE M.C. SHALL VERIFY CONTROL CONNECTIONS FOR ALL EXISTING EXHAUST FANS. THE M.C. SHALL VERIFY CONTROL CONNECTIONS FOR ALL EXISTING EXHAUST FANS. IF CONTROLS DO NOT EXIST, THE M.C. SHALL COORDINATE WITH THE E.C. TO PROVIDE NEW CONTROLS AND POWER CONNECTIONS TO ALL EXHAUST FANS. ALL EXHAUST FAN CONTROLS SHALL BE FED FROM THE NEAREST CRITICAL POWER SOURCE. 15. THE M.C. SHALL BE RESPONSIBLE FOR THE RECERTIFICATION (IN ACCORDANCE WITH THE M.C. SHALL BE RESPONSIBLE FOR THE RECERTIFICATION (IN ACCORDANCE WITH ASHE 110) OF ALL LABORATORY FUME HOODS BY WHICH THEIR CORRESPONDING EXHAUST FANS HAVE BEEN REPLACED. 16. EQUIPMENT PURCHASED AS PART OF THIS CONTRACT SHALL MEET THE "BUY EQUIPMENT PURCHASED AS PART OF THIS CONTRACT SHALL MEET THE "BUY AMERICAN ACT" 17. REFER TO GI-003 FOR GROUPING PLAN. REFER TO GI-003 FOR GROUPING PLAN. SHEET METAL 1. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." 2. PROVIDE BEARING PLATES AND OTHER NECESSARY REINFORCEMENT AT DUCTWORK PROVIDE BEARING PLATES AND OTHER NECESSARY REINFORCEMENT AT DUCTWORK SUPPORTS TO ENSURE THAT DUCT INSULATION MAINTAINS REQUIRED "R" VALUES. 3. PROVIDE ACCESS DOORS IN DUCTWORK WHERE INDICATED OR REQUIRED FOR ACCESS PROVIDE ACCESS DOORS IN DUCTWORK WHERE INDICATED OR REQUIRED FOR ACCESS TO SYSTEM COMPONENTS INCLUDING THE FOLLOWING: A) DAMPER MOTORS AND/OR MOTOR OPERATED DAMPERS DAMPER MOTORS AND/OR MOTOR OPERATED DAMPERS B) FILTERS FILTERS C) FIRE DAMPERS AND SMOKE DAMPERS FIRE DAMPERS AND SMOKE DAMPERS 4. PROVIDE TURNING VANES IN ALL SQUARE OR RECTANGULAR DUCT ELBOWS AND ON PROVIDE TURNING VANES IN ALL SQUARE OR RECTANGULAR DUCT ELBOWS AND ON ROUND DUCT WITH LESS THAN LONG RADIUS ELBOWS.
AutoCAD SHX Text
MECHANICAL SPACE CONDITIONING SYSTEMS: EXISTING TO REMAIN.
AutoCAD SHX Text
BUILDING COOLING LOAD: N/A
AutoCAD SHX Text
BUILDING HEATING LOAD: N/A
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT.
AutoCAD SHX Text
METHOD OF COMPLIANCE: PRESCRIPTIVE
AutoCAD SHX Text
CODE ENFORCEMENT JURISDICTION: VAMC
AutoCAD SHX Text
NAME OF PROJECT: VA DURHAM
AutoCAD SHX Text
BUILDING OCCUPANCY: I-2
AutoCAD SHX Text
ADDRESS: DURHAM, NORTH CAROLINA
AutoCAD SHX Text
EXTERIOR DESIGN CONDITIONS:
AutoCAD SHX Text
WINTER DRY BULB: 16%%DF
AutoCAD SHX Text
SUMMER DRY BULB: 94%%DF
AutoCAD SHX Text
CLIMATE ZONE: 4A
AutoCAD SHX Text
PROJECT AREA:
AutoCAD SHX Text
PROPOSED USE: HOSPITAL
AutoCAD SHX Text
RELATIVE HUMIDITY: 20%%% -60%%% R.H.
AutoCAD SHX Text
INTERIOR DESIGN CONDITIONS:
AutoCAD SHX Text
WINTER DRY BULB: 70%%DF
AutoCAD SHX Text
SUMMER DRY BULB: 75%%DF
AutoCAD SHX Text
ENERGY RECOVERY UNIT:
AutoCAD SHX Text
FIXED PLATE SYSTEM EFFICIENCY SUMMER TIME: 65%%%
AutoCAD SHX Text
SUMMER WET BULB: 76%%DF
AutoCAD SHX Text A. M.C. SHALL PERFORM AND SUBMIT AHU-16 TESTING AND BALANCING REPORTS TO M.C. SHALL PERFORM AND SUBMIT AHU-16 TESTING AND BALANCING REPORTS TO VA COR BEFORE DEMOLITION BEGINS AND AFTER PROJECT COMPLETION. REPORTS SHALL INCLUDE: 1. AHU-16 FAN, MOTOR, AND COIL PERFORMANCE DATA. AHU-16 FAN, MOTOR, AND COIL PERFORMANCE DATA. a. FAN DATA TO INCLUDE, BUT NOT LIMITED TO, MANUFACTURER, MODEL FAN DATA TO INCLUDE, BUT NOT LIMITED TO, MANUFACTURER, MODEL NUMBER, RPM, CFM, ENTERING STATIC PRESSURE, DISCHARGE STATIC PRESSURE, STATIC PRESSURE PROFILE, AND FILTER DIFFERENTIAL PRESSURE. b. MOTOR DATA TO INCLUDE, BUT NOT LIMITED TO, MANUFACTURER, MODEL MOTOR DATA TO INCLUDE, BUT NOT LIMITED TO, MANUFACTURER, MODEL NUMBER, SERIAL NUMBER, HORSEPOWER, RPM, VOLTAGE AND AMPERAGE DATA. c.