S02_-_Drawings_-_659-17-101.pdf
PDF 34 MB Posted
- Attached to
- Renovate Building 2-Medical Surgical 659-17-101
- Solicitation number
- 36C24618R0711
About this file
S02_-_Drawings_-_659-17-101.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24618R0711-0007000.docx | DOCX document | |
| 36C24618R0711-0007002.pdf | ||
| 36C24618R0711-0007003.pdf | ||
| 36C24618R0711-0007004.pdf | ||
| 36C24618R0711-0007001.pdf | ||
| 36C24618R0711-0005000.docx | DOCX document | |
| 36C24618R0711-0004002.pdf | ||
| 36C24618R0711-0004001.pdf | ||
| 36C24618R0711-0004000.docx | DOCX document | |
| 36C24618R0711-0004003.pdf | ||
| 36C24618R0711-0003001.docx | DOCX document | |
| 36C24618R0711-0002001.pdf | ||
| 36C24618R0711-0002002.pdf | ||
| 36C24618R0711-0002000.docx | DOCX document | |
| 36C24618R0711-00001000.docx | DOCX document | |
| 36C24618R0711-014.pdf | ||
| 36C24618R0711-018.pdf | ||
| 36C24618R0711-016.pdf | ||
| 36C24618R0711-015.txt | TXT text file | |
| 36C24618R0711-017.pdf | ||
| 36C24618R0711-013.docx | DOCX document | |
| 36C24618R0711-000.docx | DOCX document |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAD
Stamp
NOTE:
Reproductions of fire resistive designs are included herein for convenience only, and illustrate assemblies or designs specified for use to accomplish the fire resistance ratings required by applicable code. The design professional in applying his seal to this sheet of the Contract Documents certifies that only information furnished by a source approved by the authority having jurisdiction has been incorporated into these documents; however, no certification is made regarding the accuracy and completeness of the information shown.
Designs of assemblies, materials, and methods of construction used to protect joints and penetrations in fire resistance rated building elements are shown herein for those penetrations commonly encountered in construction of projects of this nature. The selection of appropriate materials and methods necessary to address specific conditions not shown herein remains with the Contractor, and shall be of a design that has been tested in accordance with ASTM E119 by a source approved by the authority having jurisdiction.
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
Date: Checked: Drawn:
Dwg.
3/08/2018 --
Atriax, pllc
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
F
8701 RED OAK BLVD. SUITE 500
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
UL DESIGN ASSEMBLIES
GI002
TG KEN
BY REVISIONS DATE
NOTE:
Reproductions of fire resistive designs are included herein for convenience only, and illustrate assemblies or designs specified for use to accomplish the fire resistance ratings required by applicable code. The design professional in applying his seal to this sheet of the Contract Documents certifies that only information furnished by a source approved by the authority having jurisdiction has been incorporated into these documents; however, no certification is made regarding the accuracy and completeness of the information shown.
Designs of assemblies, materials, and methods of construction used to protect joints and penetrations in fire resistance rated building elements are shown herein for those penetrations commonly encountered in construction of projects of this nature. The selection of appropriate materials and methods necessary to address specific conditions not shown herein remains with the Contractor, and shall be of a design that has been tested in accordance with ASTM E119 by a source approved by the authority having jurisdiction.
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
U L DESIGN ASSEMBLIES
GI003
TG KEN
BY REVISIONS DATE
A
A
B
C D
DC
LIFE SAFETY LEGEND
HOURLY RATING
NEW CONSTRUCTION - EXTEND TO
UNDERSIDE OF STRUCTURE ABOVE, UNO
60" EXIT WIDTH
EGRESS TRAVEL DISTANCE
TD X'-X"
EXIT SIGN
NOTES
SUITE HATCH
SMOKE COMPARTMENT HATCH
EGRESS CORRIDOR
SUITE EXIT
EXISTING CONSTRUCTION TO REMAIN
1. REFERENCED CODE: NFPA 101 LIFE SAFETY CODE,
2. REFERENCED BASIS OF DESIGN: VETERANS
ADMINISTRATION TECHNICAL INFORMATION LIBRARY
DESIGN GUIDES.
3. EXISTING LIFE SAFETY INFORMATION BASED ON
INFORMATION PROVIDED BY THE OWNER.
4. SLEEPING SUITE COMPLIES WITH NFPA CHAPTER 19 -
EXISTING CONSTRUCTION
5. EXISTING BUILDING IS 5 STORIES
6. ENTIRE THIRD FLOOR HAS 292 OCUPANTS.
7. ENTIRE FACILITY IS REPORTED TO BE FULLY
SPRINKLERED.
1 HOUR RATED
1 HOUR SMOKE/RATED
SMOKE PARTITION
(NOT RATED)
2 HOUR RATED
2 HOUR SMOKE/RATED
3 HOUR RATED
3 HOUR SMOKE/RATED
4 HOUR RATED
4 HOUR SMOKE/RATED
EXIT
HORIZONTAL EXIT
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CONNECTION VALVE CABINET
A35
TLT
3017A
TLT
TLT
CLEAN
PAT. RM
PAT. RM.
PAT. RM
PAT. RM
PAT. RM.
PAT. RM.
TLT.
3013A
TLT
3014A
TLT
3019A
TLT
3018A
EQUIPMENT
WAITING
TLT
3087A
ELEC.
3088A
CONSULT
3190K
COPY/FAX
3190A
NURSE
MANAGER
3190I
NURSE
STATION
NURSE
STATION
STAFF
WORKROOM
PAT. RM.
CORR
ISO. PAT.
ROOM
ISO PAT.
ROOM
STAIR #3
EXAM/TREATMENT
TLT.
TLT.
TLT.
TLT.
PAT.RM.
PAT. RM.
PAT. BATH
PAT. RM.
CHARTING
ELEC.
CONFERENCE
PAT. TLT.
PAT. RM.
STOR.
STOR.
PAT. RM.
3036 PAT. TLT.
PAT. TLT.
PAT. RM.
3042 PAT. TLT.
STAIR
STAIR
CLEAN
UTILITY
PAT. TLT.
PAT. TLT.
PAT. RM.
ANTE
PAT. TLT.
PAT. RM.
ANTE
SW/BATH
PAT. RM
PAT. TLT.
PAT. RM.
PAT. RM.
NOURISHMENT
STAIR #4
PAT. RM.
PAT. RM
ISO PAT.RM.
STORAGE
PAT. RM.
PAT. BATH
PAT.RM.
PAT. RM
CLEAN
LINEN
ANTE RM.
PAT. BATH
SOILED
UTILITY
PAT. BATH
PAT. RM.
ISO PAT.
BATH
PAT. BATH
PAT. BATH
PAT. BATH
BARIATRIC.
RM.
PAT. RM.
PAT. RM
CLEAN
UTILITY
STAIR #1
3002A
STAIR #1
3001A
PAT. RM.
PAT. TLT.
PAT. TLT.
PAT. RM.
HAC
MECH
PAT. RM.
PAT. TLT.
PAT. TLT
PAT. RM.
PAT. RM.
PAT. TLT.
BARI. BATH
ELEC.
TLT.
TLT.
STAFF
WORK ROOM
MEDICATION
SOILED
LINEN
STAFF
LOCKER
MED GAS
TLT
3015A
PHARM/PHARM
TECH
3190B
NURSE
MANAGER
3190J
CHIEF
NURSE
3190H
CHIEF
3190G
UNASSIGNED
3190F
UM NURSE
U M
N U
R S
E S
E
UM NURSE
UM NURSE
ASST CHIEF
NURSE
3190D
PAT. RM
TLT
3086A
PAT. RM
SOILED
IT & ELEC.
PAT. RM
BUSINESS SUITE
WITHIN 1-2 OCCUPANCY
2347 S.F. (100SF/PERSON) = 24 OCCUPANTS
MEDICAL SURGICAL SMOKE COMPARTMENT
(INCLUDES BUSINESS SUITE) SHOWN
HATCHED
I-2 OCCUPANCY 11,211 S.F.
8,864 MED SURG / 120 = 74 OCCUPANTS
TOTAL OCCUPANCY 100
STAFF TLT
A13
A16 A17
A19A15
A.F A.F
A22
A.G A.G
A.C A.C
A24 A27A21
A25 A28 A34A30 A31A11
A20
A26
A12 A14
A8
A8
A9
A9
A.K A.K
A.JA.J
HAC
STAIR #6
SUPPLY
EXISTING
BREAK
3101A
EXISTING
OFFICE
EXISTING
CONFERENCE
EDUCATOR
OFC.
3190L
TLT
3016A TOILET
3020A
MED GAS
OFFICE
ELEV.
IT
FEC
FECFEC
FEC FEC
PHASE ONE:
THIS ENTIRE AREA SHALL HAVE DEMOLITION
AND RENOVATIONS COMPLETED BEFORE
DEMOLITION AND CONSTRUCTION BEGINS IN
REMAINING AREAS.
B
PHASE ONE:
THIS ENTIRE AREA SHALL HAVE DEMOLITION
AND RENOVATIONS COMPLETED BEFORE
DEMOLITION AND CONSTRUCTION BEGINS IN
REMAINING AREAS.
SOCIAL
WORKERS
3190C
ELEV.
EQUIPMENT
CORR
CORR
LINEN
PHASE TWO
THE REMAINING AREA WITHIN THE SCOPE OF
WORK SHALL HAVE DEMOLITION AND
RENOVATIONS COMPLETED AFTER
CONSTRUCTION IS FINISHED IN PHASE ONE
NOTE:
HATCHED AREAS ARE WITHIN THE SMOKE
COMPARTMENT, BUT ARE NOT IN THE
SCOPE OF WORK, EXCEPT FOR REPLACING
DOORS.
NOTE:
PATINET ROOM 3020 IS NOT WITHIN THE
SMOKE COMPARTMENT, BUT IS IN THE
SCOPE OF WORK
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
THIRD FLOOR LIFE SAFETY
PLAN
GI102
TG JO
3/32" = 1'-0"1
THIRD FLOOR LIFE SAFETY
EGRESS TRAVEL DISTANCE
Path ID Travel Distance Comments
A 73'-11 15/16" TRAVEL DISTANCE TO SUITE EXIT. 100' ALLOWABLE
B 106'-6" TRAVEL DISTANCE TO EXIT
C 105'-3 9/16" TRAVEL DISTANCE TO SMOKE COMPARTMENT
D 88'-0" TRAVEL DISTANCE TO EXIT
KEYNOTES - LIFE SAFETY
Image Description
MAINTAIN MINIMUM 6' - 0" WIDE EMERGENCY EGRESS CORRIDOR
THROUGHOUT CONSTRUCTION
REFER TO OWNER PROVIDED LIFE SAFETY PLAN FOR INFORMATION
IN THIS AREA OF THE BUILDING, NO WORK
32" CLEAR OPENING / 0.3 LOAD FACTOR = 107 ALLOWED, 37 ACTUAL
EXITING
DIAGONAL MEASUREMENT 414'/3 = 138' MINIMUM DISTANCE
DISTANCE BETWEEN EXITS 158' - 0"
SMOKE COMPARTMENT EGRESS DOORS. 68" CLEAR OPENING / 0.3
LOAD FACTOR = 226 ALLOWED 37 ACTUAL EXITING
SERVICE ELEVATOR TO REMAIN OPERATIONAL DURING
CONSTRUCTION
PASSENGER ELEVATOR TO REMAIN OPERATIONAL DURING
CONSTRUCTION
PLAN
NORTH
BY REVISIONS DATE
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
THIRD FLOOR OWNER
PROVIDED LIFE SAFETY PLAN -
FOR REFERENCE ONLY
GI103
TG CAF
BY REVISIONS DATE
www.atriaxgroup.com
102 3rd Avenue, NE
PO Box 1629, Hickory, NC 28603
T: 828.315.9962
F: 828.315.9964
NC Engineering License No.: P-0214
NC Architectural License No.: 51254
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
PHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
LeGrand
Engineering, Inc.
215 PARK AVE SE
AIKEN, SC 29801
PHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com
8701 RED OAK BLVD. SUITE 500
CHARLOTTE, NC 28217-5593
PHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
A35A13
A16 A17
A19A15
A.F A.F
A22
A.G A.G
A.C A.C
A24 A27A21
A25 A28 A34
A34
A30
A30
A31
A31
A11
A20
A26
A12 A14
A8
A8
A9
A9
A.K A.K
A.JA.J
D1
D1
D1
D3
D2
D2
D3
D3
D3
D2
D6 D6
D6D5
5'-2" 10 1/2"
D8 D8
D8
D8
D8
D8
D8
D9
D5
D2
D10
D10D10 D10
D10
D11
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED
DEMO LEGEND PLAN
NORTH
GENERAL NOTES
1. WALLS, CEILINGS, FLOOR FINISHES, DOORS/FRAMES,
COLUMN COVERS, FINISHES, CONVECTORS, HVAC AS
NOTED, PLUMBING FIXTURES, ELECTRICAL DEVICES
AS NOTED, PIPING AND MED GAS LINES TO BE
DEMOLISHED UNLESS NOTES OTHERWISE.
2. MAINTAIN OWNER APPROVED EMERGENCY EGRESS
AND PATH TO EXIT WAY WITH MINIMUM
CLEARANCE OF 5' - 0" CLEAR.
3. ALL DEMOLITION SHALL BE COMPLETED WHILE
PROVIDING VA STAFF UNHINDERED ACCESS TO THE
NORTH AND SOUTH WINGS.
4. STAIRS AND ELEVATORS TO REMAIN FULLY
OPERATIONAL DURING DEMOLITION AND
CONSTRUCTION.
5. CONTRACTOR TO PROVIDE TEMPORARY 1HR ICRA
APPROVED PARTITIONS. COORDINATE WITH NEW
WORK BEING INCLUDED IN THE SCOPE OF THIS
PROJECT, GENERAL NOTES IN THIS SET OF
DRAWINGS, AND REQUIRED CONSTRUCTION
CONTRACTOR TO PROVIDE ANTE ROOMS FOR
INGRESS/EGRESS.
6. COORDINATE DEMOLITION WITH PROPOSED NEW
WORK WITH OWNER PRIOR TO BEGINNING OF
CONSTRUCTION.
7. MOVEABLE EQUIPMENT TO BE REMOVED BY OWNER
PRIOR TO CONSTRUCTION.
8. ALL REMOVED EQUIPMENT SHALL BE TURNED OVER
TO THE OWNER AND STORED WHERE DIRECTED.
ITEMS THE OWNER DOES NOT WANT TO KEEP SHALL
BE REMOVED AND PROPERLY DISPOSED OF BY THE
CONTRACTOR.
9. CONTRACTOR TO REWORK ANY FUNCTIONING
UTILITIES OR PIPING AS REQUIRED FOR
CONSTRUCTION.
10. FLOOR LEVELING AND MOISTURE MITIGATION SHALL
BE INSTALLED AFTER DEMOLITION AND BEFORE NEW
WALLS ARE INSTALLED.
DAY ROOM
OFFICE
3101A
EXAM
OFFICE
OFFICE
OFFICE
3094K
OFFICE
3094J
OFFICE
3094A
OFFICE
3094B
OFFICE
3094I
CONF. ROOM
3094C
OFFICE
3094H
GEN.
STORAGE
3094L
OFFICE
3094G
OFFICE
3094D
OFFICE
3094E
OFFICE
3159 SUPP
CORR
ICE
EKG
EKG
SOIL LIN
STAIR #5
NURSE
STATION
3145 STO.
STO.
M. TLT.
TLT.
STO.
LINL
STORAGE
F. TLT.
MOP
ELEC.
M TLT.
NURSE
STATION
L. CHUTE
MOP CLOS.
3058A
MEDICATION.
3059A
TLT
OFFICE
NOURISHMENT
MSCU ISOL
TLT.
STOR
STOR
F. TLT.
TELE
3091A
LAB STOR.
WAITING
ELEC.
CORRIDOR
STAIR #6
1-BED
TLT.
1-BED
TLT.
1-BED
TLT.
LOCKER
ROOM
TLT 3014
TLT
1-BED
TLT
1-BED
1-BED
STOR.
TLT.
1-BED
1-BED
TLT.
1-BED
TLT
TLT.
DIALYSIS
TLT
STOR.
1-BED
CL. UTILITY
CONFERENCE
PAT. RM
3060WORK ROOM
HAC
PAT. RM.
PAT. TLT.
PAT. TLT
PAT. RM.
PAT. TLT.
BARI. BATH
BARIATRIC.
RM.
UTILITY
STAFF
WORK ROOM
MEDICATION
CLEAN
LINEN
NOURISHMENT
STORAGE
ANTE RM.
ISO PAT.RM.
PAT.RM.
PAT. RM.
PAT BAT
PAT. RM
PAT. RM
PAT BATH
SOILED
UTILITY
ELEC.
PAT. RM.
STAIR #4
ISO PAT.
BATH
PAT. BATH
PAT. BATH
PAT. RM.
PAT. BATH
EXAM/TREATMENT
PAT. BATH
STORE
3082B
5 BED MSCU
PAT. RM.
STAFF
LOCKER
ELEC.
FAC
3165A
ELEC.
FAC
ELEV. PIT
ELEV. EQUIP.
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
THIRD FLOOR DEMOLITION
PLAN
AD101
TG KEN
KEYNOTES - DEMO...
Image Description
DEMOLISH PAPRTITIONS, DOORS, FLOORS,
FINISHES, PLUMBING FIXTURES, ELECTRICAL
DEVICES, CEILINGS, MILLWORK, AND ALL OTHER
RELATED ITEMS SHOWN DASHED IN AREA
INDICATED. CONTRACTOR TO FULLY INSPECT
THE AREA AT PREBID MEETING TO UNDERSTAND
SCOPE OF DEMOLITION
EXISTING GLAZED CMU TO REMAIN. SCARIFY
SURFACE AS REQ'D FOR PLASTER SKIM COAT
NO WORK IN THIS ROOM
ELEVATORS TO REMAIN OPERATIONAL DURING
CONSTRUCTION. G.C. TO COORD TEMP. SHUT
DOWNS W/ OTHERS PROIR TO ANY DISRUPTIONS.
MAINTAIN MIN 6' CLEAR EGRESS PATH DURING
CONSTRUCTION.
OFFICE SUITE RENOVATION -DEDUCT
ALTERNATE #1
REMOVE DOOR AND FRAME. PREP FOR NEW
DOOR IN THIS LOCATION
FUTURE EXISTING ELEVATOR AREA-SCOPE OF
WORK NOT INCLUDED IN CONTRACT
GRIND/DEMO EXISTING FLOOR SLAB AS
REQUIRED FOR NEW TILE AND DRAIN
INSTALLATION
DEMO CEILING AS REQUIRED FOR NEW MEP
WORK
1/8" = 1'-0"1
THIRD FLOOR DEMOLITION
D7
D10
BY REVISIONS DATE
Revision 1 Date 1
B000
-61 SF
3017A
TLT
60 SF
-67 SF
TLT
60 SF
-58 SF
TLT
60 SF
-225 SF
PAT. RM
280 SF
-230 SF
PAT. RM.
280 SF -229 SF
PAT. RM
280 SF
-231 SF
PAT. RM
280 SF
-214 SF
PAT. RM.
280 SF -228 SF
PAT. RM.
280 SF
-78 SF
3013A
TLT.
60 SF
-59 SF
3014A
TLT
60 SF
-60 SF
3016A
TLT
60 SF
-58 SF
3019A
TLT
60 SF
-60 SF
3018A
TLT
60 SF
-238 SF
WAITING
175 SF
-63 SF
3087A
TLT
60 SF
NURSE
STATION
ELEC.
3088A
-117 SF
3190K
CONSULT
112 SF
-103 SF
3190A
COPY/FAX
100 SF
-121 SF
3190I
NURSE MANAGER
100 SF
NURSE
STATION
STAFF
WORKROOM
-291 SF
PAT. RM.
280 SF
PAT. TLT.
PAT. RM.
STOR.
STOR.
NOURISHMENT
STORAGE
CLEAN
LINEN
HAC
MECH
PAT. RM.
54 SF
PAT. TLT
STAFF
LOCKER
-244 SF
3190F
UNASSIGNED
300 SF
-126 SF
3190H
CHIEF NURSE
100 SF
-129 SF
3190G
CHIEF
100 SF
-118 SF
3190J
NURSE MANAGER
100 SF
-174 SF
3190E
UM NURSES
-126 SF
3190C
SOCIAL WORKERS
112 SF
-119 SF
3190B
PHARM/PHARM TECH
112 SF
-127 SF
3190D
ASST CHIEF NURSE
100 SF
-44 SF
MED GAS
36 SF
CORR
-59 SF
3015A
TLT
60 SF
-229 SF
PAT. RM
280 SF
IT & ELEC.
-280 SF
PAT. RM
280 SF
-64 SF
3086A
TLT
60 SF
-276 SF
PAT. RM
280 SF
EXISTING
OFFICE
-100 SF
EQUIPMENT
300 SF
SOILED
LINEN
-70 SF
UM NURSE
56 SF
-70 SF
UM NURSE
56 SF
-70 SF
UM NURSE
56 SF
9'-3 1/4" 15'-9 1/2" 15'-8 5/8" 5'-10 3/4" 3'-4 7/8" 15'-7 1/8" 15'-3 1/8" 9'-7" 15'-9 7/8" 14'-8 1/4"
5'-10 7/8"
3'-6 1/2"
1'-1 1/8"
'-2
8'
-0
'-6
M
IN
. C
LE
A R
8' -0
'-2
5' -7
/2
7' -1
1/
2" 7'
-9
/4
3'-0 1/8"
1' -6
9'-6" 9'-6" 1'-4" 7'-10 1/4"
8' -0
18'-6 1/4" 6'-7 1/4" 3'-5 1/4"
3'-4 1/4"
8' -3
/2
8'
-8
/4
8' -8
/4
9'
-0
'-0
7' -3
/4
8'
-3
/2
8' -8
/4
8'
-8
/4
B103 B16S2 B16S2
B16S2
B16S1
B16S2
B16
3013A
3014A
3015A
3016A
3017A
3018A
3019A
A
3087A
3086A
3190K
3190J
3190I
3190H
3190G 3190E
3190D
3190C
3190B
3190A
A
B102
B102
B100B
B102
A
3162A
B100B102 B102B100
B102 B100B102B100
B102
B100B102
TYP.
B102
ELEC.
3100A
2 2
-47 SF
STAFF TLT
60 SF
-70 SF
3020A
TOILET
60 SF
3020A
B
A13
A16 A17
A19A15
A.F
A22
A.G
A.C
A24 A27A21
A25 A28 A34A30 A31A11
A20
A26
A12 A14
A8 A9
A.K
A.J
AE401
15'-5 7/16" +/-
AE402
1' -3
/2
EXISTING
BREAK
3101A
EXISTING
CONFERENCE
OFFICE
FAC
3162A
A
STAIR #5
FAC
CORR
3163 STAIR #6
CORR
HALL
8' -3
18'-5 1/2"
LINEN
A
AE401
MIN. CLEAR
8'-0"
15'-11 1/2" +/-
AE402
'-8
/4
1'-10 3/4"
1'-6 3/4"
3190F
-96 SF
3190L
EDUCATOR OFC.
100 SF
-48 SF
MED GAS
SUPPLY
CLEAN
-105 SF
SOILED
75 SF
B
-38 SF
HAC
B
A
B13S1
B13S1 B13S1
B13S1
B13S1
B103
B103
1'-9"
B102
3/
8"
IT
ELEV.
OFFICE
ELEC.
ELEV.
EQUIPMENT
B16S2
8' -0
B 168'
-0
B
B
AE401
AE401
AE401
AE401
2'-0"2'-0"
1'-11"
3' -3
1'
-3
/2
1'-3 1/8"
7'-2 3/8"
4' -5
/4
2'-2 1/8"
135.00° 135.00°
B100B100
B103
B42
TYP
8 TYP.
TYP
TYP
TYP
TYP
1'-3"
B16
TYP.
TYP
CR
CR
CR
CR
CR
CR
CR CR
CR
CR
CR
CR
CR CR
CR
HOURLY RATING
GENERAL NOTES
1. ELEVATORS TO REMAIN FULLY OPERATION
DURING CONSTRUCTION COORDINATE ANY TEMP.
SHUT DOWNS WITH OWNER PRIOR TO ANY
DISRUPTION.
2. ALL WALLS TO BE CLEAR OF WINDOWS.
3. FLOOR LEVELING IS REQUIRED AFTER DEMO AND
BEFORE NEW WALLS ARE INSTALLED.
4. FACILITY IS REPORTED TO BE 100%
SPRINKLERED.
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION - EXTEND TO
UNDERSIDE OF STRUCTURE ABOVE
PARTITION TYPE DESIGNATION - SEE
A8.1 SHEETS. NOTE: ALL INTERIOR
PARTITIONS NOT OTHERWISE
INDICATED ARE TO BE B13
LEGEND
NEW CONSTRUCTION - EXTEND TO
UNDERSIDE OF STRUCTURE ABOVE
1 HOUR RATED
1 HOUR SMOKE/RATED
SMOKE PARTITION
(NOT RATED)
2 HOUR RATED
2 HOUR SMOKE/RATED
FURNITURE - OWNER
FURNISHED/OWNER INSTALLED
PATIENT HEADWALL SYSTEM (OFOI)
A5075
EQUIPMENT TAG- SEE SHEETS
AE603 AND A604
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
THIRD FLOOR PLAN
AE101
TG JO
1/8" = 1'-0"1
THIRD FLOOR PLAN
KEYNOTES - NEW FLOOR PLAN
Image Description
ALIGN NEW WALL WITH EXISTING
EXISTING WINDOW TO REMAIN, CLOSED TO INTERIOR. PAINT INTERIOR OF
WINDOW.
PROVIDE ABRASION RESISTANT COATING OVER EXISTING GLAZED BLOCK
WALLS. SCARIFY EXISTING GLAZED BLOCK AS REQ'D.
HEADWALL SYSTEM OF/OI
NO WORK IN THIS AREA
OFFICE SUITE RENOVATION- DEDUCT ALTERNATE #1
FUTURE EXISTING ELEVATOR AREA-SCOPE OF WORK NOT INCLUDED IN
CONTRACT
MILLWORK CF/CI
SLOPE FINISH FLOOR MIN 1/8"/FT TO DRAIN. PROVIDE SMOOTH, LEVEL
TRANSITION TO PATIENT ROOM AT TOILET ROOM DOOR. TYP ALL PATIENT
TOILET ROOMS.
PHASE 1 REQUIRED CEILING WORK IN THIS AREA IF DEDUCT ALTERNATE 1 IS
ACCEPTED
PATCH, REPAIR AND PAINT WALLS, AS REQUIRED DUE TO CEILING
REPLACEMENT. NO OTHER WORK IN THIS ROOM
PLAN
NORTH
BY REVISIONS DATE
RECESSED DOWN LIGHT
EXIT LIGHT (CEILING OR WALL MTD.)
2' x 2' ACOUSTICAL CEILING TILE, SEE FINISH SCHEDULE FOR TYPES
GYPSUM BOARD CEILING / SOFFIT
CEILING HEIGHT AFF (SEE PLAN)
SPRINKLER HEAD
MECHANICAL GRILLE
WALL MOUNTED LIGHT
LED LIGHT FIXTURES
ACCESS PANEL (24" x 24")
NEW CONSTRUCTION - EXTEND TO
UNDERSIDE OF STRUCTURE ABOVE
AP
GENERAL NOTES:
1. ALL CEILING HEIGHTS TO BE CORDINATED/CONFIRMED
WITH UTILITES AND REQ'D CLEARANCES.
2. MAJOR MECHANICAL AND ELECTRICAL ITEMS ARE
SHOWN ON THIS DRAWING FOR GENERAL LOCATIONS
WITHIN THE CEILING SYSTEM. SEE MECHANICAL AND
ELECTRICAL DRAWINGS FOR INFORMATION DESCRIBING
THE SYSTEM TO WHICH THEY BELONG AND FOR
ADDITIONAL CEILING MOUNTED DEVICES.
3. CEILING TILE SHALL BE CENTERED WITHIN THE SPACE
AND SYMMETRICALLY CUT AT WALLS UNLESS NOTED
OTHERWISE.
XX'-XX"
CUBICLE CURTAIN TRACK TO BE
INSTALLED BY CONTRACTOR.
PROVIDE CURVES AT CORNERS.
HOURLY RATING
PLAN
NORTH
CEILING LEGEND
1 HOUR RATED
2 HOUR RATED
SMOKE PARTITION
(NO WALL DESIGNATION)
3 HOUR RATED
AE401
A35
A35
EQUIPMENT
TLT.
3013A
MED GAS
3012 PAT. RM
PAT. RM.
TLT
3015A
TLT
3014A
PAT. RM
PAT. RM
TLT
3017A
PAT. RM
3017 PAT. RM.
TLT
3019A
TLT
3018A
PAT. RM.
TOILET
3020A
PAT. RM.
CORR
CLEAN
TLT
TLT
IT & ELEC.
EXISTING
OFFICE
CONSULT
3190K
NURSE
MANAGER
3190J
NURSE
MANAGER
3190I
CHIEF
NURSE
3190H
CHIEF
3190G
UNASSIGNED
3190F
UM NURSES
3190E
ASST CHIEF
NURSE
3190D
126 SF
SOCIAL
WORKERS
3190C
PHARM/PHARM
TECH
3190B
COPY/FAX
3190A
STAFF TLT
WAITING
ELEC.
3088AELEC.
3100A
PAT. RM
TLT
3086A
TLT
3087A
PAT. RM
A13
A16 A17
A19A15
A.F
A22
A.G
A.C
A24 A27A21
A25 A28 A34A30 A31A11
A20
A26
A12 A14
A8 A9
8'-8"
A.K
A.J
8'-8"
8'-0" 8'-0"8'-0"
8'-0"
8'-0"
7'-2"
7'-4"
7'-4"
AE401 8
7'-4"
7'-4"
SUPPLY
STOR.
STOR.
PAT. RM.
PAT. TLT.
PAT. RM.
PAT. TLT.
PAT. TLT.
PAT. RM
CONFERENCE
NURSE
STATION
6054STAIR #6
NURSE
STATION
STAIR #5
SOILED
LINEN
STAFF
WORKROOM
HAC
MECH
PAT. RM.
PAT. TLT.
BARIATRIC.
RM.
CLEAN
UTILITY
STAFF
WORK ROOM
MEDICATION
NOURISHMENT
OFFICE
EXISTING
CONFERENCE
EXISTING
BREAK
3101A
TLT
3016A
7'-4"
8'-8"
8'-10"
8'-10"
7'-2"
8'-10"
8'-10"
8'-10"
SOILED
3169 EXIST
EXIST
CEILING.
8'-8" 8'-10"
8'-10"
8'-10"
8'-8"8'-8" 8'-8" 8'-8" 8'-8"
8'-8"
8'-10" 8'-10"8'-10"
8'-10"
8'-10"
8'-10"
8'-0"
8'-0"
8'-0"
8'-8"
7'-4"7'-4"
8'-10"
8'-0"
8'-10"
7'-4" 7'-4"7'-4"7'-4"
7'-2"
7'-4"
8'-0"
8'-6"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
MED GAS
CORR
CORR
STAFF
LOCKER
3200CLEAN
LINEN
LINEN
HALL
7' -4
AE401
RADIANT
PANEL TYP.
IT
7' -4
7'
-4
7' -4
7'
-4
7' -4
7' -4
7'
-4
7' -4
7' -4
1' -6
1' -6
3' -7
4' -0
/2
EQUAL EQUAL
2'-9" 2'-9" 1' -6
8'-8"
3' -7
"1' -6
2'-9" 2'-9"
3' -7
" 1' -6
1'-10" 1'-10"
2'-0" 2'-0"
2'-0" 2'-0"1'-9" 1'-9"
1' -4
2'-0" 2'-0" 1'-9"1'-9"
2'-2" 2'-2"1'-10"1'-10"
1/
4"
2'-2" 2'-2"1'-10" 1'-10"
2' -1
0"
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
THIRD FLOOR REFLECTED
CEILING PLAN
AE102
TG KEN
KEYNOTES - NEW...
PATCH AND REPAIR EXISTING CLG. TO MATCH
NO CEILING IN THIS AREA
COORDINATE CLG DEMO WITH NEW CONSTRUCTION
PATIENT LIFT SYSTEM AND TRACK OF/OI.
COORDINATE WITH CEILING DESIGN, LIGHT
FIXTURES AND CEILING MOUNTED MECHANICAL
DEVICES
NO WORK IN THIS AREA
OFFICE SUITE RENOVATION DEDUCT ALTERNATE #1
FUTURE EXISTING ELEVATOR AREA-SCOPE OF
WORK NOT INCLUDED IN CONTRACT
REUSE EXISTING 2'x4" LED FIXTURES
1/8" = 1'-0"1
THIRD FLOOR REFLECTED CEILING PLAN
RAISED CEILING
AREA FOR
ELEVATOR
LIGHTING @ 7'-8"
BY REVISIONS DATE
B000
TLT
3017A
TLT
TLT
3167CLEAN
PAT. RM
PAT. RM
PAT. RM
PAT. RM.
PAT. RM.
3019TLT
3014A
TLT
3016A
TLT
3019A
TLT
3018A
WAITING
TLT
3087A
A35
TLT.
3013A
MED GAS
3012 PAT. RM.
TLT
3015A
PAT. RM
PAT. RM.
TOILET
3020A
SOILED
IT & ELEC.
EXISTING
OFFICE
CONSULT
3190K
NURSE
MANAGER
3190J
NURSE
MANAGER
3190I
CHIEF
NURSE
3190H
CHIEF
3190G
UNASSIGNED
3190F UM NURSES
3190E
UM NURSE
UM NURSE
UM NURSE
ASST CHIEF
NURSE
3190D
SOCIAL
WORKERS
3190C
PHARM/PHARM
TECH
3190B
COPY/FAX
3190A
STAFF TLT
PAT. RM
TLT
3086A
PAT. RM
A13
A16 A17
A19A15
A.F
A22
A.G
A.C
A24 A27A21
A25 A28 A34A30 A31A11
A20
A26
A12 A14
A8 A9
A.K
A.J
AE401
AE402
AE401
EQUIPMENT
ELEV.
3177 OFFICE
EXISTING
BREAK
3101A
EXISTING
CONFERENCE
OFFICE
EDUCATOR
OFC.
3190L
CORR
HALL
IT
SUPPLY
MED GAS
CORR
HAC
STAIR #6
STAIR #5
CORR
ELEC.
M13150
E0945
M2050
HOURLY RATING
GENERAL NOTES
1. REFER TO A600 SHEETS FOR EQUIPMENT LIST.
2. REFER TO ENLARGED PLAS FOR DETAILED
INFORMATION FOR TYPICAL PATIENT ROOMS
AND OTHER AREAS.
3. CONTRACTOR TO COORDINATE WITH VA AND
PATIENT ROOM EQUIPMENT SUPPLIER TO PLAN
INFRASTRUCTURE & UTILITY TIE INS WITH
ELECTRICAL, GAS AND MECHANICAL.
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION - EXTEND TO
UNDERSIDE OF STRUCTURE ABOVE
PARTITION TYPE DESIGNATION - SEE
A8.1 SHEETS. NOTE: ALL INTERIOR
PARTITIONS NOT OTHERWISE
INDICATED ARE TO BE B14
LEGEND
NEW CONSTRUCTION - EXTEND TO
UNDERSIDE OF STRUCTURE ABOVE
1 HOUR RATED
1 HOUR SMOKE/RATED
SMOKE PARTITION
(NOT RATED)
2 HOUR RATED
2 HOUR SMOKE/RATED
FURNITURE - OWNER
FURNISHED/OWNER INSTALLED
PATIENT HEADWALL SYSTEM OF/OI
PLAN
NORTH
NOTE:
FURNITURE AND EQUIPMENT SHOWN FOR REFERENCE ONLY
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
THIRD FLOOR EQUIPMENT
PLAN
AE103
TG KEN
1/8" = 1'-0"1
THIRD FLOOR EQUIPMENT PLAN
BY REVISIONS DATE
A16
A.C
A.K
2' -0
8'-10"
CUSTOM
HEADWALL
UNIT (OFOI)
7'-4"
8'-8"
8'-10"
PATIENT LIFT
AND TRACK
2' -7
1' -3
/8
4'-8 7/8" 4'-8 7/8"
2' -4
/2
2'-5" 2'-5 7/8" add can lights coord MEP
PARTIAL
HEIGHT DOOR
D0710
M0500 F3050
A5180
A5108
3'-1"
2' -6
26"X36"
OPEN
A16
M3070
A5080 A5075
SOFFIT
501.18190P.30 21"
DEEP
SLOPED
PANEL
1 1/2" FILLER
STRIPMILLWORK CF/CI
SEE DETAIL 13/AE402
A.C
O V
UPPER CABINET
TO HOUSE MOTOR
FOR PATIENT LIFT
3 CAN LIGHTS
INTEGRATED INTO
THE HEADWALL SYSTEM
PATIENT HEADWALL SYSTEM OF/OI: ALL
DEVICE CONNECTIONS & OUTLETS TO BE
COORDINATED WITH UTILITY, MECH &
PLUMBING. THIS INCLUDES BUT NOT LIMITED
TO NURSE CALL, CODE BLUE, DATA,
ELECTRICAL AND MED GASES.
ROLLING
DOOR-GASES
BEYOND
SURFACE MOUNTED
OUTLETS
PATIENT LIFT
(OF/OI)
SOFFIT
SOFFIT
M7010
A16
F0376
A1110
SLEEPER
RECLINER
2' -6
AE4013 5
A16 A17
A.C
A.K
B13
B103
B13S2
B16
B100 B102
B13
1' -9
/1
6"
5'
-8
/4
8' -6
/1
6"
6' -2
/8
1'
-6
/4
7'-1 3/4" 8'-5 3/8"
B16S2
B103
B103
B102 B103
B102 TYP. AT ALL
EXT. WALLS
B103
B100
3'-4 7/8"
9'-3 5/8" 2 1/8"
3'-0"
AE401
TLT
3015A
PAT. RM
SS SHELF
SHOWER
CONTROLS
1'-8"
AE401
1' -6
/8
1'-5 1/4"
HEAD WALL
SYSTEM
OF/OI
MILLWORK
CF/CI
MILLWORK
CF/CI
PROVIDE MIN 1/8" SLOPE
TO DRAIN. TYP ALL
PATIENT TOILET ROOMS
PROVIDE SMOOTH,
LEVEL TRANSITION TO
PATIENT ROOM. TYP ALL
PATIENT TOILET ROOMS
A.G
A.J
AE401 8
SOILED
F0535
F0535
F0510
190P.30
P6500
A5080
A5075
BASE
1'-6 3/8"
MILLWORK CF/CI
SEE DETAIL 13/AE402 SIM.
CONSTRUCT SOFFIT
FROM THIS POINT
UP PRIOR TO
INSTALLATION OF
CEILING
PLAM / WD. VENEER
FACED CLOSURE TRIM
PLAM / WD. VENEER
FIN. CLG. - SEE REFLECTED
CLG. PLAN FOR HEIGHT
GYP. BD. SOFFIT ON
METAL STUDS
1/2" MIN BACK
PANEL TYPICAL
BRACE TO
STRUCTURE
ABOVE
PULL HARDWARE
1x BLKG CONT.
@ FRONT-SHIM
@ REAR
WOOD BLOCKING
4" 2'-2"
BASE AS SCHEDULED 2 x FRT WD. BLOCKING
AT 24" O.C. MAX. (TYP.)
1 1/8" 1'-9 1/2"
1"
3/ 4"
4"
3/ 4"
1' -8
DOUBLE HOOK ON
EACH SIDE WITH
COAT ROD
NOTE: FULL HEIGHT
DOORS ARE
REQUIRED, 1-1/8"
PLAM. / WD.
VENEER COVERED
HOLLOW CORE
DOORS REQ.
3"
2 3/8"
FIXED SHELF
7' -4
1'
-0
V
A R
IE
S
S E
E P
LA
N
CONT. SUPPORT
FOR COUNTERTOP
REAR OFFSET
DRAIN REQ. AT
UNIT 190P1.
DUE TO
SLOPED PANEL
REMOVABLE 3/4" EXTERIOR
PLYWOOD PANEL W/ PLAM.
ALL SURFACES EXCEPT
BACKING SHEET ON BACK
SIDE. SCREW TO 2X4 BLKG.
WITH RECESSED TAMPER
PROOF SCREWS. STOP
PANEL 1/2" FROM WALL EACH
END.
BASE AS SCHEDULED
1/ 2"
1/
2"4" 6"
2' -4
2' -1
0"
2' -3
M
IN
8" MIN
3/4"
FINISH FLOOR
COUNTERTOP FINISH
AS SCHEDULED
6" MAX
9" M
IN
501.18 191A.42
1 1/2" FILLER
253.18
F F
291.30 254.12
100.21 190.30
OPEN
WRAP PIPING
W/ INSUL
101.18
UNIT DESIGNATION
UNIT WIDTH
2 SIM
COLUMN
TYP. EXPOSED END
CARRY REVEAL
THROUGH
EXPOSED END
PANEL SHALL
BE ONE
PIECE (TYP.)
LIGHT VALANCE
RECESSED 3/16"
BOTH FRONT
AND SIDE
MILLWORK LEGEND
100 SERIES; BASE UNITS W/O DRAWERS
200 SERIES; BASE UNITS W/ DRAWERS
300 SERIES; WALL UNITS
400 SERIES; TALL STORAGE UNITS
500 SERIES; WARDROBE
SPECIFIC UNITS
301B.12
UNIT WIDTH (INCHES)
UNIT TYPE
UNIT SERIES
NOTES:
1) COUNTERTOP AND BACKSPLASH
SHALL BE INSTALLED IN ONE PIECE.
2) BACKSPLASH SHALL BE RETURNED
WITH SEPARATE PIECES AT ALL ENDS
WHERE WALL OR OTHER CABINET
OCCURS.
3) SCRIBE BACK AND END SPLASH TO
WALL.
DOOR
FILLER
DOWEL
HOLES
*NOTE: AT CORNER WHERE TWO
CABS. ABUT @ 90 DEGREES,
DIMENSION SHALL BE 2"
1 1/2" *
SCRIBE
TO WALL
FACE OF
WALL DOWEL HOLES
DOOR
EXPOSED
FINISHED
END
PLAM./WD VENEER
SCRIBE
TO WALL
FACE OF
WALL
COUNTERTOP
CAULK
4"
BASE CABINET
1'-3"
OPEN
BELOW
1/
2"
APRON
SOLID SURFACE
SINK WITH
INTEGRAL BOWL2'
-1 0"
CURVED COUNTER &
APRON. PROVIDE ADA
INSULATION ON EXPOSED
PIPING. CF/CI
A1066
A5075
A5080
A16
A.K
EXISTING COLUMN
7/8" HAT CHANNEL
B100
B102
B100
B
B102
2' -0
/4
1'-3"
1' -9
B
1/
8"
B
2 EXISTING EXTERIOR
WINDOW SYSTEM
EXISTING
EXTERIOR
WALL
B13 B103
ALIGN WITH EXISTING
WINDOW RETURN.
PATCH, REPAIR AND
PROVIDE NEW FINISHES.
9 3/8"
A19
B100
B13
B100
1'-2 5/8"
EXISTING COLUMN
EXISTING
EXTERIOR
WALL
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
ENLARGED PLANS
AE401
TG KEN
1/4" = 1'-0"2
PATIENT ROOM RCP
3/8" = 1'-0"3
WEST ELEVATION
3/8" = 1'-0"4
NORTH ELEVATION
3/8" = 1'-0"5
EAST ELEVATION
3/8" = 1'-0"6
SOUTH ELEVATION
1/4" = 1'-0"1
TYPICAL PATIENT ROOM
1/4" = 1'-0"7
ENLARGED SOILED ROOM PLAN
3/8" = 1'-0"8
SOILED ELEVATION
1 1/2" = 1'-0"10
501 WARDROBE
1 1/2" = 1'-0"9
190P: ACCESSIBLE SINK BASE CAB W/ PANEL
5 2 7
3/8" = 1'-0"11
PATIENT TOILET ROOM-TYP.
1 1/2" = 1'-0"18
ENLARGED COL. PLAN
1 1/2" = 1'-0"19
ENLRG PLAN @ WINDOW
1 1/2" = 1'-0"20
PLAN AT COL. 19
NOTE:
ALL DEVICES, CONNECTIONS AND
OUTLETS TO BE COORDINATED WITH
ELECTRICAL, PLUMBING AND
MECHANICAL.
BY REVISIONS DATE
SCHEDULED
FLOOR AS
2"
2" X 3/8" MARBLE
THRESHOLD WITH BEVEL
BOTH SIDES
CT ON THIN SET WITH
WATERPROOF MEMBRANE
DOOR
DOOR FRAME
1/2" MIRROR WITH
STAINLESS STEEL
CHANNEL FRAME
MIRROR HANGER
BLOCKING OR
METAL STRAPPING
FOR HANGER
SUPPORT
ALLOW AT LEAST 1" SPACE
BETWEEN BACKSPLASH AND
MIRROR FOR CONNECTION.
BACKSPLASH
A T
F T
O R
E F
LE
C
T
IN
G S
U R
F A
C E
1"
C DRAIN
1/4" MIRROR
L
C OUTLET
7' -0
2'-0"
2"X2"X1/4" L @ END
WALLS ANGLED
BETWEEN 3"X3"X1/4"
3"X3"X1/4" L @ END
WALLS AND
INTERMEDIATEA AS
REQUIRED
REMOVABLE 3/4"
EXTERIOR PLYWOOD
PANEL W/ PLAM. ALL
SURFACES EXCEPT
BACKING SHEET ON
BACK SIDE SCREW TO
2x4 BLKG. W/
RECESSED TAMPER
PROOF SCREWS THAT
STOP PANEL 1/2" FROM
WALL EACH END.
MC 3X9 @ EACH L BRACE W/
3/8" BASE PLATE SECURED TO
STRUCTURAL ABOVE AT MIDPOINT OF
VANITY LENGTH OR AS INDICATED
SOLID SURFACE COUNTER
END & BACKSPLASH
NOTE: DETAIL USES 1 1/4" DIA PIPE FOR DRAIN
- ADJUST FRAMEWORK FOR LARGER PIPE.
NOTE:
COORDINATE
LOCATION OF
STRUCTURE WITH
PLUMBING LINES
NOTE:
COORDINATE LOCATION
OF ANGLE FRAMEWORK
W/ SIZE AND
CONFIGURATION OF
PLUMBING LINES.
SECURE L TO
MC3x9
REGAL MIRROR FRAME
MOULDING #290 WHERE
INDICATED
FINISH FLOOR
3"
3/8"BASE
PLATE
5 3/4"
3/
4"
8 1/2" MIN
5" 6"
2' -1
0"
56" X 60" W.C. CLR.
FLR. SPACE
WATER CLOSET
42" GRAB BARS
WALL HUNG LAVATORY
36" GRAB BARS
30" X 48" LAV. CLR FLR. SPACE PER
606.2 & 305.3 ANSI A117.1
NAPKIN DISPOSAL (@
WOMENS TLT)
TISSUE HOLDER
MIRROR
TOWEL DISPENSER
1' -0
6'-0"
MAX
1'-0"
MIN
3'-6"
1' -3
M
IN
M A
X
6" 3'
-0
M
IN
2' -6
5'
-0
7' -6
1' -6
6'-0"
4'-0" MIN DOOR CLEARANCE
METAL STUD
METAL BLOCKING PLATE
CEMENT BOARD
CERAMIC TILE
GRAB BAR
ESCUTCHEON PLATE
ATTACHMENT SCREW
METAL SLEEVE
1.5"MAX.
1.25" MIN.
1 1/2"
CONTRACTOR OPTION FOR
FT 2X6 WOOD BLOCKING
2' -6
1' -6
3'-0" CLEAR
1'-6"
3' -0
7" 1'-0" 2 1/2"
MAX.
"M
A X
M A
X . 1
/2
3" M
A X
1'-0"MIN.
TO FACE OF WALL
MOUNT SEAT 1'-6"
AFF
"M
IN
22" MIN.
23"MAX.
C O
N T
R O
L W
A
LL
S E
A T
W A
LL
FINISH TO FINISH
VERT.
GRAB BAR
1'-6"
6" 2'-6"
6' -4
5' -1
1'
-1
SLOPE SLOPE
HAND HELD HOSE
OPERATING LEVER
1/2" LIP MAX (NO LIP AT
ROLL-IN SHOWER)
CERAMIC TILE
SHOWER HEAD
DIVERSION VALVE
SOAP DISH
GRAB BAR
SHOWER CURTAIN ROD
CONTROL WALL ELEV.
AREA FOR SHOWER CONTROLS
3' -2
4' -0
CERAMIC TILE ON CEMENT
BOARD
5/ 8"
FACE
OF TILE
5/8" GYP.
WHERE
INDICATED
2 1/2" METAL STUD
4" METAL STUD
C3X4.1
1/ 2"
4"
C4X5.4 W/
FACES FLUSH
COPE HORIZ
C4 AROUND
C3 SUPPORT
C3X4.1 VERTICAL
SUPPORTS SECURE TO
FLOOR WITH 3" X 3" X
1/4" X 0'-3" CLIP ANGLE.
WELD TO C3 AND
ANCHOR TO FLOOR
WITH 3/4" DIA
EXPANSION ANCHOR.
WELD ABOVE TO 3 1/2"
X 3 1/2" X 1/4" ANGLE AS
REQUIRED. SECURE TO
BUILDING STRUCTURAL
WELD
3" X 3" X 1/4" X 4" CLIP
ANGLE WELD TO C4 &
ANCHOR TO FLOOR W/ 3/4"
DIA EXPOSED BOLTS
1' -3
/2
4"
2'-10"
1'-5" 1'-5"
BASE PLATE WITH
SPRING AT TOP
C 3X4.1 BEYOND. EXTEND TO 3 1/2" x 3 1/2" x 1/4" CLIP ANGLE AT
STRUCTURAL ABOVE - SEE DETAIL
UPPER
MOUNTING
FLANGE
3 1/2" X 3 1/2" X
1/4" CLIP
L-SECURE TO BLDG.
STRUCTURAL
CERAMIC TILE ON
CEMENT BD OVER
5/8" GYP DB
SUPPORT ARM
COPE METAL FRAMING
AROUND CHANNELS AS
REQUIRED
GUIDE BRACKET
FINISHED FLOOR
C4X5.4'S
1' -6
1/
2"
3/ 8"
1/
8"
1' -6
1' -3
/2
1/
4"
V E
R
IF
Y D
IM
.S
W / S
E A
T M
F G
METAL STUDS
5/8" CEMENT BACKER BOARD
REINFORCED MORTAR BED
- SLOPE FILL 1/4" PER FT
WATERPROOFING MEMBRANE - CARRY
UP WALL TO TOP OF TILE
5/8" GYP BD
SEALANT
1/4"
(MIN.)
FLOOR DECK
WATERPROOFING MEMBRANE
OVER MORTAR BED EXTEND UP
WALL 6" MIN.
CERAMIC TILE ON
THIN SET MORTARCAULK JOINTS BETWEEN
THRESHOLD AND TILE
FINISHED FLOOR - SEE
FINISH SCHED FOR TYPE
1/2" SSM SLOPED
THRESHOLD
SLOPE FLOOR TO
DOOR AS REQ'D
SEALANT @ JOINTS
BETWEEN THRESHOLD
AND TILE
1/2" SSM SLOPED
THRESHOLD
FLOOR DRAIN
1/ 4"
TILE EDGE TRIM
6"
CONT. BLOCKING
1/2" CEMENT BACKER BOARD
TILE - SEE FIN. SCHEDULE
2" MAX
2" MAX
WATER PROOFING MEMBRANE
A19
INTEGRAL SINK
PAPER TOWEL
DISPENSER CLEAR
1'-6"
M
IN
3' -6
M A
X
1' -0
5' -0
1' -6
MIN DOOR CLEARANCE
5'-0"
TISSUE HOLDER
F .O
. D O
O R
T O
F .O
. S T
O P
2' -8
M
IN
C
LE
A
R 3'
-0
30" X 48" CLEAR
FLOOR SPACE
56" X 60" W.C. CLR FLR. SPACE
MIN. CLEAR
2'-6"1'-11 1/4"
5' -0
1'
-1 0"
9'-0"
A30 A31
A.K
-70 SF
TOILET
3020A
60 SF
3'-7 1/4" 5'-5 7/8"
2' -0
/4
9' -1
0"
4 1/4"
6' -9
/2
4'-4 1/4"
EXTEND TILE
FLOOR INTO
SHOWER, PROVIDE
MIN. 1/8"/FT SLOPE
TO DRAIN
1'-1
3'-4 3/8"
6 3/8"
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
TOILET ROOM DETAILS
AE402
TG KEN
3" = 1'-0"5
THRESHOLD AT PUBLIC/PATIENT TOILET DETAIL
6" = 1'-0"6
MIRROR DETAIL
1 1/2" = 1'-0"13
LAVATORY COUNTER ATTACHMENT TO REAR WALL SECTION
1/2" = 1'-0"3
TOILET OPTION OUTSWING DOOR
3" = 1'-0"7
GRAB BAR ATTACHMENT (W/ SLEEVE)
3/4" = 1'-0"4
TRANSFER ACCESSIBLE HANDICAP SHOWER PLAN
3/4" = 1'-0"14
ACCESSIBLE SHOWER/PLUMBING
WALL (TYPICAL)
1 1/2" = 1'-0"12
SHOWER SEAT PLAN/SECTION
1 1/2" = 1'-0"8
CHANNEL FRAME SUPPORT FOR
FOLDING SHOWER SEAT DETAIL
1 1/2" = 1'-0"9
SHOWER SEAT SECTION
3" = 1'-0"10
TYPICAL ADA SHOWER BASIN DETAIL
1/2" = 1'-0"2
ACCESSIBLE STAFF TOILET INSWING DOOR (ANSI A117.1)
1/4" = 1'-0"1
TOILET ROOM 3020A
BY REVISIONS DATE
METAL STUDS
@16" O.C. TO
STRUCTURE ABOVE
4"
8"
M
IN
MAX.
5/8" GYPSUM BOARD
7/8" FURRING CHANNEL
1-1/2" COLD ROLLED
CHANNELS
4" MTL. STUDS TO
STRUCTURE
ABOVE@4'-0" O.C
WALL ANGLE
V A
R
IE
S
SPACER BAR
NOTE: SEE REFLECTED
CEILING PLAN FORHEIGHTS
4 5/8"
3/8"
V A
R
IE
S
METAL STUDS @16" O.C TO
STRUCTURE ABOVE
3/8"
8"
MAX.
3/8"
5 1/4"
MTL. STUDS @ 4'-0" O.C. TO
STRUCTURE ABOVE
5/8" GYPSUM
BOARD
SCHEDULED ACT CEILING
WALL ANGLE
SPACER BAR
NOTE: SEE REFLECTED
CEILING PLAN FORHEIGHTS
1 1/2"
(2) METAL WIRE
HANGERS TO STRUCTURE
ABOVE FOR EACH
METAL STUD SUPPORT
CEILING TRACK
NOTE: CONTRACTOR TO COORDINATE CURTAIN TRACK CLEARANCE
WITH LIGHT FIXTURES, MECHANICAL DIFFUSERS AND SPRINKLER HEADS.
NESTED 20
GAUGE METAL
STUDS @ 24"
O.C.
CEILING TILE &
GRID SCHEDULED
WIRE
HANGERS
TO STRUCT
ABOVE
SPACERS
SUPPORT SECTION
T Y
P
4" V
A R
IE
S
METAL STUDS TO
STRUCT. ABOVE
METAL STUD BRACING
@ 4'-0" MAX.
SCHEDULED CEILING
5/8" GYP. BD.
5/8" GYP. BD.
WALL ANGLE
2"
1/2" MIN.
SLIDING FIXED (OPTION)
TWO ADJACENT SIDES ONLY
12 GA METAL HANGER
WIRE
STRUT
STABILIZER OR
SIMILAR DEVICE
CROSS RUNNER
NAIL
2"
CROSS RUNNER
POP RIVET- OPTIONAL 2 ADJACENT
SIDES ONLY
SCHEDULED CEILING
N1 N2
8" OR LESS
8" OR LESS
NOTES:
WALL ANGLES OR CHANNELS ARE CONSIDERED AESTHETIC CLOSERS AND SHALL HAVE NO
STRUCTURAL VALUE. PERMANENT RUNNER ATTACHMENT TO THE WALL ANGLES OR
CHANNELS IS NOT PERMITTED.
INSTALLATION IS INTENDED TO PROVIDE AN UNRESTRAINED AND FREE FLOATING CEILING
SYSTEM THAT WILL PERMIT AND ACCOMMODATE MOVEMENT OF THE STRUCTURE DURING
A SIESMIC EVENT.
ALL GRID SYSTEMS SHOULD BE INSTALLED TO MEET MANUFACTURER'S
RECOMMENDATIONS MEETING THE CRITERIA FOR SYSTEMS TESTED TO COMPLY WITH THE
REQUIREMENTS OF ASTM E580 FOR SEISMIC CATEGORY C.
ALL ACCESSORIES RECOMMENDED BY THE MANUFACTURER FOR CEILING SUSPENSION
SYSTEMS TESTED TO COMPLY WITH THE REQUIREMENTS OF ASTM E580 FOR SEISMIC
CATEGORY SHALL BE INCORPORATED INTO THE INSTALLATION.
ALL LIGHTING FIXTURES AND SERVICES WITHIN THE CEILING SHALL BE INSTALLED AND
SUPPORTED TO COMPLY WITH ALL REQUIREMENTS OF ASTM E580.
SPACER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP
PERIMETER COMPONENTS FROM SPREADING APART.
(REQUIRED REGARDLESS OF LEDGES WIDTH.)
3/8" MIN
10 MAX.
12-ga HANGER WIRE PERIMETER
SUPPORTS TWO ALTERNATIVES:
1) 12-GA HANGER WIRE ANCHORED
TO STRUCTURE ABOVE AND HUNG
VERTICALLY (±10 ) A MAX. OF 8"
FROM THE PERIMETER.
10 MAX.
8"
2) 12-GA HANGER WIRE ANCHORED
TO PERIMETER WALL. ATTACHMENT
TO GRID MAY BE WITHIN 8" FROM
THE WALL, BUT THE WALL
ATTACHMENT WIRE MUST NOT
EXCEED A 1/6 SLOPE (10 ).
MIN. 3/8"
MIN. 7/8"
NOTE:
VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER TO
PREVENT ANY VERTICAL MOVEMENT OR ROTATION OF THE MEMBER WITHIN
THE LOOPS. INSTALLATION SHALL COMPLY WITH ASTM E580, CATEGORY C.
RUNNER ATTACHMENT TO THE WALL ANGLES OR
CHANNELS IS NOT PERMITED.
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
CEILING DETAILS
AE501
Checker Author
1 1/2" = 1'-0"3
BULKHEAD DETAIL
1 1/2" = 1'-0"4
BULKHEAD DETAIL
3" = 1'-0"2
CUBICLE CURTAIN TRACK 1 1/2" = 1'-0"1
SOFFIT DETAIL
3" = 1'-0"5
WALL CLOSURE DETAIL
3" = 1'-0"6
WALL CLOSURE DETAIL
BY REVISIONS DATE
STAGGER VERT JOINTS SO THEY OCCUR
OVER DIFFERENT STUDS ON OPPOSITE
SIDES OF PARTITION & STAGGER JOINTS OF
SECOND LAYER FROM FIRST LAYER
OVERLAP ENDS OF EACH LAYER OF GYP
BD AT CORNERS AS INDICATED
4'-0" GB PANEL
4'-0" GB PANEL
4'-0" GB PANEL
STUD SPACING
16" MAX
4'-0" GB PANEL
NOTE: FOR WALL TYPES
& RATING SEE PLANS
EXTERIOR WALL CONSTRUCTION - SEE WALL SECTIONS FOR EXACT CONSTRUCTION
5/8" FIRERATED GYP BD ON METAL STUDS
16" O.C. (2 LAYERS WHERE REQD)
EXTERIOR GYPSUM SHEETING
BUILDING
INSULATION
EXTERIOR BUILDING
SKIN
AIR SPACE
P2
P1
DEFLECTION TRACK
DOUBLE E-STUDS
TRACK
TRACK
4'-0" MAX
3' -0
M
A X
NOTE: DETAIL AT INTERSECTION OF PARTITION W/ROOF CONSTRUCTION SIMILAR
NOTE: WHERE MTL DECK IS REQUIRED TO BE FIREPROOFED STUD TRACK
RUNNER SHALL BE SECURED TO 33 MIL. Z-CLIP ATTACHED TO MTL DECK AT 16" OC
MINIMUM
FLOOR CONSTRUCTION
DEFLECTION HEAD TRACK WITH SLOTTED
FASTENER OPENINGS
2 LAYERS 5/8" FIRERATED GB WHERE
APPLICABLE - SEE PLANS
TYPICAL SMOKE-PARTITION, RATED PARTITION OR
SMOKE AND RATED PARTITION, 5/8" RATED GYP BD
EA SIDE OF MTL STUDS @ 16" OC
FIN CLG - SEE FIN SCHEDULE
FOR HEIGHT & TYPE
METAL STUDS 16" O.C.
SEAL TIGHT TO DECK
PER TESTED ASSEMBLY
VARIES ACCORDING TO
THICKNESS OF CABINET -
SEE PLANS
2 1/2" STUDS W/ 1 1/2" THK
MINERAL WOOL BATTS
5/8" FIRERATED GYP BD ON MTL STUDS (2
LAYERS IF 2 HOUR WALL)
BASED ON UL
U420 & UL U448
5/8" FIRERATED GYP BD ON
METSTUDS (2 LAYERS IF 2 HOUR WALL)
SEE PLANS FOR RECESSED METHOD USED/TO BE USED ON ALL
PENETRATIONS EXCEEDING 16 SQ.IN.
ALCOVE IN WALL FOR
CABINET TO HAVE GYPSUM
BOARD ON ALL 5 SURFACES;
NUMBER OF LAYERS PER
RATING REQUIRED
1/
2" M
IN
VERIFY W/
CABINET SPECIFIED
VERIFY W/
CABINET SPECIFIED
(EXACT DESIGN PER STUD TYPE & TESTED DESIGN)
NOTE:
DAMPERS INSTALLATIONS VARY, INSTALL
PER MFG. INSTRUCTIONS & TESTED
DESIGN
NOTE: GYPSUM PANELS TO BE
SCREWED TO ALL STUD AND RUNNER
FLANGES ON 12" MAX CENTERS,
SURROUNDING THE OPENING
P2
P1
DEFLECTION TRACK
STUD (S)
90° BEND RUNNER
FLOOR RUNNER
2 HOUR
DAMPER
OPENING
1 HOUR
PANHEAD
SCREWS (4 TYP)
2" 2"
1' -0
NOTE: WHERE MTL DECK IS REQUIRED TO BE SPRAY FIREPROOFED STUD TRACK RUNNER SHALL BE
SECURED TO 33 MIL. GA Z-CLIP ATTACHED TO MTL DECK AT 16" OC MINIMUM
FLOOR CONSTRUCTION
33 MIL. Z-CLIP @ 16"OC
SPRAY APPLIED FIREPROOFING
UPDATED FIRE STUFFING
1 0R 2 LAYERS OF 5/8" FIRE-RATED
GYP BD ON VERTICAL SURFACE AS
REQD (SEE WALL
TYPES)
DEFLECTION HEAD TRACK WITH
SLOTTED FASTENER OPENINGS
METAL STUDS 16" O.C.
1 OR 2 LAYERS OF 5/8" FIRE
RATED GYP. BD. AS FIRE RATED
2 1/2" MET
STUDS 16" OC
SEALED TIGHT
PER TESTED
ASSEMBLY
CONCRETE DECK
DEFLECTION
TRACKS
METAL
STUDS
BEYOND
CONTINUOUS
DEFLECTION
TRACK
CUT GYP. BD.
TO FIT - SEAL
TIGHT TO DECK
& BEAM W/
FIRE RATED
ASSEMBLY
1 0R 2 LAYERS OF 5/8"
FIRE RATED GYP. BD. AS
REQ'D
2 1/2" MET
STUDS 16" OC
SEAL TIGHT TO DECK PER
TESTED ASSEMBLY
SEAL TIGHT TO DECK
PER TESTED ASSEMBLY
CONRETE DECK
DEFLECTION TRACKS
2 1/2" MET
STUDS 16" OC
SEAL TIGHT TO DECK
PER TESTED ASSEMBLY
CONCRETE DECK
DEFLECTION TRACK
1 OR 2 LAYERS OF
GYP. BD. EACH
SIDE AS REQ'D
INTUMESCENT PAD -
BOXES ON ONE
SIDE OF WALL ONLY
RATED GYPSUM
BOARD WALL
RATED ELECT. DEVICE
MAX 16 SQUARE INCH
OPENING IN RATED OR
SMOKE WALL (MAX. 4" X 4")
NOTE: WHERE DISTANCE
BETWEEN CENTER OF
BOXES IS 24" OR GREATER, NO
INTUMESCENT PAD REQUIRED.
R A
T E
D W
A
LL
> 24" >24"
J-TRACK HEADER
RETAINING ANGLE
J-TRACK SILL
J-STUD SLOTTED
UPPER AND LOWER TO
ALLOW FOR
PENETRATION OPENING
DAMPER
ANGLE MOUNTED
TO J-TRACK WITH
LOW PROFILE
SCREWS
RETAINING ANGLE
J-TRACK SILL
DAMPER
J-TRACK HEADER
E-STUD CUT UPPER AND LOWER
TO ALLOW FOR PENETRATION
OPENING
Department of
Veterans Affairs
1 2 3 4 5 6 7 8 9
Project Title Project Number
Building Number
Drawing Number of
Location
RENOVATE BUILDING 2
FOR MEDICAL SURGICAL
MODERNIZATION
1 2 3 4 5 6 7 8 9
CONSULTANTS: SEAL: ARCHITECT/ENGINEERS:
Drawing Title
Approved Project Director:
102 3RD AVENUE, NE
PO BOX 1629
HICKORY, NC 28603
PHONE: 828.315.9962
FAX: 828.315.9964
8845 RED OAK BLVD.
CHARLOTTE, NC 28217-5593
TELEPHONE: 704.523.2230
FAX: 704.523.2235
www.freemanwhite.com
215 PARK AVE SE
AIKEN, SC 29801
TELEPHONE: 803.502.0657
FAX: 803.643.4648
www.legrandengineering.com www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architecture License No.: 51254
Office of Construction and Facilities Management
A
B
C
D
E
F
O N E E
IG
H
TH
IN
C H
O N E
F O O T
O N E Q U A R
TE
R
IN
C H
O N E
F O O T
TH
R E E E
IG
H
TH
S
IN
C H
O N E
F O O T
O N E H A
LF
IN
C H
O N E
F O O T
TH
R E E Q U A R
TE
R S
IN
C H
O N E
F O O T
O N E
IN
C H
O N E
F O O T
O N E
A N D
O N E H A
LF
IN
C H E S
O N E
F O O T
TH
R E E
IN
C H E S
O N E
F O O T
A
B
C
D
E
TELEPHONE: 704.522.0495
FAX: 704.522.0499
www.lrspc.net
659-17-101
W.G. HEFNER VAMC SALISBURY NC
SMOKE, FIRE, JOINT DETAILS
AE502
Checker Author
3/4" = 1'-0"1
DRYWALL RATED PARTITIONS
1" = 1'-0"8
SCHEMATIC RATED WALL TO EXTERIOR WALL
1/2" = 1'-0"10
STUD LOCATIONS AT FIRE DAMPERS W/ SHAFT
WALL CONSTRUCTION
1" = 1'-0"2
TYPICAL RATED PARTITION DETAIL
1" = 1'-0"4
TYPICAL RECESSED CABINET IN RATED PARTITION
1/2" = 1'-0"7
TYPICAL STUD LOCATIONS AT FIRE DAMPERS IN
RATED WALLS
1" = 1'-0"3
RATED WALL UNDER BEAM
1" = 1'-0"11
RATED WALL OR SMOKE WALL UNDER CONC. BEAM
OR JOIST
1" = 1'-0"12
RATED WALLS PERPENDICULAR TO CONC. BEAM OR
JOIST
1" = 1'-0"15
RATED WALL UNDER CONC. BEAM OR JOIST
1" = 1'-0"13
WALL WITHIN 12" OF CONC. BEAM DETAIL
1" = 1'-0"14
ELECTRICAL BOXES IN RATED AND SMOKE WALL
DETAIL
1" = 1'-0"16
FRAMING SECTION (I-STUDS)
1" = 1'-0"17
FRAMING SECTION (E-STUDS)
BY REVISIONS DATE
NOTE: MAX SIZE OF PIPING TO BE SUPPORTED
FROM COMPOSITE FLOOR IS 4". ANYTHING
LARGER TO BE SUPPORTED FROM STRUCTURAL
STEEL FRAMING.
ROOF LEADERS LARGER THAN 4"
MAY BE HUNG WITH ANGLE
FRAMING
CONC.
DECK CONSTRUCTION
HILTI KWICK BOLTS OR EQUAL
HILTI KWICK BOLTS OR
EQUAL
L2 x 2 x 3/16"
TOP OF CONDUIT, PIPE, DUCT, ETC.
(OR INSUL- ATION IF INSULATED)
I
THICKNESS OF FIREPROOFING
REQD + 1/2" MIN CLEAR
E-STUD CUT TO ALLOW FOR
PENETRATION OPENING
J-RUNNER HEADER-TOP OF
OPENING
1 1/2"X1 1/2"X 2" L SCREW ATTACHED W/ 5/8" TYPE
S-12 LOW PROFILE HEAD SCREWS
J-RUNNER BOTTOM OF
OPENING
E-STUD CUT TO ALLOW FOR
PENETRATION OPENING
DETAIL 2
DETAIL 1
NOTE:
2 LAYERS OF GYP BD AT 2-HOUR WALLS
ALL SCREWS SHALL BE SPACED 3" OC MAX
ALL SCREW HEADS SHALL BE LEFT EXPOSED
ALL PATCHES TO BE SET IN FULL BED OF DRYWALL COMPOUND
ALL TYPE 'G' SCREWS
TYPE 'S' SCREWS 8"
OC AT DECK
TYPE 'G' SCREWS
(GYPSUM TO GYPSUM
LAMINATING SCREWS)
TYPE 'S' SCREWS
(GYPSUM TO STEEL)
FIRESAFING
CEILING LINE
C OF STUDS
PATCH FOR OPNG
LARGER THAN 3"
PATCH FOR EXIST
DUCT
PATCH FOR
OPNG 3" OR LESS
TYPTE 'G' SCREWS
CONCRETE PATCH W/ REINF.CHIP EXISTING
OPENING TO 30°
CONCRETE PATCH W/ REINF.
10/10 WWF
SPRAY
FIREPROOFING
1/2" Ø RED HEAD ANCHORS,
1 EA SIDE MIN, 1 @ 2'-0" MAX
CONC PATCH ON 3/4", 26 GA
CONC. FORM DECK
3 1/2"x3 1/2"x1/4" L ALL AROUND
OPENING-SECURE TO EXIST'G SLAB
W/1/4" Ø ANCHORS 1'-0" OC MAX
30.00°
4 x T MAX
T T
4 x T MAX
5'-0"x5'-0" MAX
FOR OPENINGS
2'-0" UP TO
NOTE: FOR WALL TYPE &
RATING, SEE PLANS
HIGHER PRIORITY
PARTITION
HIGHER PRIORITY PARTITION TO BE
CONSTRUCTED PRIOR TO ALL ADJACENT
PARTITIONS & TO BE OF TOTAL MONOLITHIC
CONSTRUCTION
TYPICAL LOWER PRIORITY PARTITIONS FRAMED TIGHT TO
& INDEPENDENT OF HIGHER PRIORITY PARTITION (1 HR
SYMBOL SHOWN)
NOTE: WHERE MTL DECK IS REQUIRED TO BE FIREPROOFED STUD TRACK
RUNNER SHALL BE SECURED TO 20 GA Z-CLIP ATTACHED TO MTL DECK AT 16" OC MINIMUM
CONC.
FLOOR CONSTRUCTION
SEAL TIGHT PER
TESTED ASSEMBLY
33 MIL Z-CLIP @ 16"OC
2 1/2" MTL STUDS 16" OC
2 LAYERS GYP BD EACH SIDE @ 1
HR RATING (3 LAYERS @ 2 HR)
SEE PARTITION TYPES
DEFLECTION TRACK
GYP BD EACH SIDE
AS REQ'D
LESS
12" OR
PRIORITY
PRIORITY
PRIORITY
PRIORITY 5
PRIORITY
PRIORITY
1TWO HOUR FIRE AND SMOKE PARTITION
TWO HOUR RATED SHAFT WALL
PARTITION TO 4" MIN ABOVE CLG
PARTITION TO DECK
ONE HOUR RATED PARTITION
ONE HOUR SMOKE PARTITION
TWO HOUR RATED PARTITION
PARTITION PRIORITY LEGEND
NOTE: ADD HORIZONTAL METAL STUD BLOCKING
BETWEEN STUDS AT ALL HORIZONTAL JOINTS AT
RATED WALLS
NOTE: JOINT BETWEEN GYP BD & FLOOR SLAB SHALL BE 3/8" MAX.
LENGTH OF PANEL IS CONTRACTORS CHOICE AT
ROOMS W/ CEILINGS & 8'-0" MIN AT ROOMS W/ NO
CEILINGS
FOR RATED & SMOKE PARTITIONS
FOR PARTITIONS TO DECK
HORIZONTAL JOINTS ARE NOT REQUIRED TO
BE STAGGERED BUT SHALL OCCUR ABOVE
THE CEILING.
HORIZONTAL JOINTS ON OPPOSITE SIDES OF THE
PARTITION ARE REQUIRED TO BE STAGGERED 2'-0"
MIN OC & SHALL OCCUR ABOVE THE CEILING
FIN
FLOOR
FIN
CEILING
DECK
FIN
FLOOR
FIN
CEILING
DECK
NOTE: SEE PARTITION TYPES
NOTE: SEE PARTITION TYPES
2' -0
M
IN
P
A N
E L
LE
N
G T
H P
A N
E L
LE
N
G T
H
LENGTH OF PANEL IS CONTRACTOR'S
CHOICE AT ROOMS W/CEILINGS & 8'-0"…
This is the start of the file's text. The full file is on GovTribe.