| AMENDMENT 0001 TO RFQ 36C24526Q0401 UPLOADED ANSWERS TO RFIS AND GENERATOR DESCRIPTIONS LOUIS A JOHNSON VAMC |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 21902 |
| SOLICITATION NUMBER* |
| 36C24526Q0401 |
| RESPONSE DATE/TIME/ZONE |
| 04-14-2026 10:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| PRODUCT SERVICE CODE* |
| J049 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
VISN 5 Contracting Satellite office
361 Boiler House Rd Perry Point MD 21902
POINT OF CONTACT*
Contracting Officer Bill Pratt Billie.Pratt@va.gov 410-642-2411
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Louis A Johnson VA Medical Center
1 Medical Ctr Dr
Clarksburg WV
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
| AGENCY CONTACT’S EMAIL ADDRESS |
| billie.pratt@va.gov |
DESCRIPTION
| GENSET #1 |
| GENSET #2 |
| GENSET #3 |
| Manufacturer/Make/Year: |
| Caterpillar |
| Caterpillar |
| Kato |
| Model No: |
| SR-4 |
| C32 |
| 500SS9D |
| Serial/Order No: |
| 6NA01031 |
| G1G00044 |
| 7319 |
Load Rating:
(Emergency/Standby/Prime)
| Frequency: |
| 60 Hertz |
| 60 Hertz |
| 60 hertz |
| Load in Amperage: |
| 1000 amps |
| 1000 amps |
| 87 |
| Output Voltage: |
| 480 |
| 480 volts |
| 4160 volts |
| Phase: |
| 3-phase |
| 3-phase |
| 3-phase |
| Building: |
| Bld 17 |
| Bld 17 |
| Bld 17 |
| Location (Area/Room): |
| Generator room |
| Generator Rm |
| Generator Rm |
| GENSET #4 |
| GENSET #5 (portable) |
| Manufacturer/Make/Year: |
| Kohler |
| Baldor |
| Model No: |
| 100RE0ZJF |
| TS225-3J |
| Serial/Order No: |
| 3346GMJL0001 |
| P1205240012 |
Load Rating:
(Emergency/Standby/Prime)
| Frequency: |
| 60 Hertz |
| 60 Hertz |
| Load in Amperage: |
| 153 amps |
| 625 amps |
| Output Voltage: |
| 480 |
| 480 volts |
| Building: |
| Parking Garage |
| Grounds |
| Location (Area/Room): |
| Parking Garage |
| Grounds (portable) |
1. Who will be responsible for the generator maintenance (monthly, quarterly, semi, annual, & triennial) an when was the last time the annual maintenance was completed?
Mountaineer Generator.
1. When was the last annual load bank testing conducted?
3/28/26.
1. Does the KATO 500kW (625KVA) 4160v generator have an integrated load bank?
NO
See attached document: 36C24526Q0401 - RFI ANSWERS.