CHEMICAL STORAGE BUILDING PRICE TEMPLATE AMEND1.xlsx
XLSX spreadsheet 13 KB Posted
- Attached to
- 8145--HAZARDOUS WASTE STORAGE UNIT RFQ AMEND 1
- Solicitation number
- 36C24526Q0052
About this file
This document is a Price Template for a Hazardous Waste Storage Building Request for Quote (RFQ) from the Department of Veterans Affairs (VA). The solicitation (36C24526Q0052) requires a fully assembled outdoor Hazardous Storage Building with specific technical requirements, including a 112 square foot design, 4-hour fire-rated walls and roof, explosion-proof features, fire suppression system, shelving, ventilation, and a moveable metal grading floor with spill containment. Key delivery specifications include destination delivery to an existing VA site pad within 200 days, with vendor responsible for offloading.
The RFQ amendment addresses vendor questions regarding installation, delivery, and site conditions, confirming that VA will be responsible for anchoring and power hookup, no fire suppression installation is required at delivery, and the delivery site has no parking, street, or placement obstacles. The RFQ close date has been extended to 11/3/25 at 12 PM EST, and the solicitation emphasizes that incomplete technical or pricing responses will be considered non-compliant. The procurement is classified under NAICS 332311 and PSC 8145, targeting a hazardous waste storage unit solution for the Veterans Health Administration's Integrated Service Network 5.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24526Q0052_2.docx | DOCX document | |
| 36C24526Q0052 AMEND 1.pdf | ||
| CHEMICAL STORAGE BUILDING PRICE TEMPLATE.xlsx | XLSX spreadsheet | |
| 36C24526Q0052.pdf | ||
| 36C24526Q0052_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Vendor NAME | |||||||
| Vendor SAM UEI | |||||||
| Contract Number | |||||||
| Manufacturer letter of authorization | |||||||
| Destination delivery date | |||||||
| ITEM NUMBER | SLIN | SOW DESCRIPTION | VENDOR SOLUTION | MODEL NAME/NUMBER | PLACE OF MANUFACTURER | PRICE | TOTAL |
| 0001 | OUTDOOR HAZARDOUS WASTE STORAGE BUILDING | ||||||
| 0001 | AA | size dimensions no larger than 112 Square feet | |||||
| 0001 | AB | staff entry 60"W x 80"H Double Door with 36" Active Leaf | |||||
| 0001 | AC | Sump Capacity: 393 gallons | |||||
| 0001 | AD | 4 Hour Fire Rated, Fire Rated Walls are tested to meet ASTM E119, and FM approved for 4 Hours, Fire Rated Roof tested to meet ASTM E119 and FM Approved for 3 Hours. | |||||
| 0001 | AE | Main breaker OP-100A Load Center 12 SPACE 100A NEMA 3R 120/240V to meet power requirements for container | |||||
| 0001 | AF | grounding kit/ tie down | |||||
| 0001 | AG | Off load site is free and clear area to operate machinery. No powerlines, sewers or obstructions will be at pad site. No bolting, electrical hook up, or fire suppression services needed at pad site. | |||||
| 0001 | AH | Explosion Proof Air Conditioner with Color Coded Thermostat Class 1, Division 2 208 Volt 15,700Btu, 230 Volt 15,700Btu (ORD) | |||||
| 0001 | AI | R11 Insulation Walls, Ceiling and DLC | |||||
| 0001 | AJ | Explosion Proof Exhaust System-335 CFM w/indicator light | |||||
| 0001 | AK | Explosion Proof Emergency Shut Off Switch for Exhaust System | |||||
| 0001 | AL | LED Explosion Proof Light Fixture with Light Switch Class 1 Division 2 | |||||
| 0001 | AM | ABC Dry Chemical Fire Suppression System with Audible Alarm vendor shall provide system requirement to be operable so the VA can ensure the fire suppression system is fully functional. | |||||
| 0001 | AN | 14"W SHELVES WITH 2" LIP SIDES (Priced Per Linear Foot) | |||||
| 0001 | AO | at least 3 tiers footage coverage length on back, left , and right walls | |||||
| 0001 | AP | 6 ACHs | |||||
| 0001 | AQ | at least one adjustable 18” W x 18H Vent with Insulated Cover | |||||
| 0001 | AR | no larger than 52"W x 72"L Perforated Steel Ramp with Skid-Resistant Finish to meet container ground height. | |||||
| 0001 | AS | Moveable metal grading full length flooring with spill containment with drain. | |||||
| 0001 | AT | destination delivery to Vexisting VA site pad within 200 days or sooner. | |||||
| 0001 | AU | Meets intertek test, FM approved |