S06 Building 1415 Report.pdf
PDF 11 MB Posted
- Solicitation number
- 36C24523B0006
About this file
This document outlines a federal contract opportunity to replace HVAC systems and renovate hallways and walls in two buildings at a Veterans Affairs medical center. The solicitation number is 36C24523B0006 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 5 to replace the HVAC, hallways, and walls in Buildings 14 and 15. The description provided indicates the work involves replacing the HVAC systems as well as renovating the hallways and walls in the two buildings. No further details are given on pricing, response dates, or other contractual requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 answer RFI revise drawings.pdf | ||
| 36C24523B0006 0007.docx | DOCX document | |
| 36C24523B0006 0006.docx | DOCX document | |
| S06 answer pre bid RFI 36C245-23-B-0006- REPLACE BLDG 14 15 HVAC AND HALLS AND WALLS - PROJ 517-16-135 - Responses (002).pdf | ||
| 36C24523B0006 0005.docx | DOCX document | |
| S06 answers to pre-bid questions 36C245-23-B-0006- REPLACE BLDG 14 15 HVAC AND HALLS AND WALLS - PROJ 517-16-135 - .pdf | ||
| 36C24523B0006 0004.docx | DOCX document | |
| 36C24523B0006 0003.docx | DOCX document | |
| S04 Pre Bid Agenda Replace Bldg 14 15.pdf | ||
| S04 Pre Bid attendance Bldg 14 15.pdf | ||
| 36C24523B0006 0002.docx | DOCX document | |
| 36C24523B0006 0001.docx | DOCX document | |
| S02 Drawings .pdf | ||
| S02 SOW Replace Building 14n15 HVAC and Halls and Walls .docx | DOCX document | |
| 36C24523B0006.docx | DOCX document | |
| S02 Wage Determination.pdf | ||
| S02 14-15 HVAC Combined Specs.pdf |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Medical Center, Beckley, WV, Building 14/15 DEC Project No. 1905.003
TARGETED SURVEY
FOR ASBESTOS AND LEAD-BASED PAINT
BUILDING 14/15
VA MEDICAL CENTER
BECKLEY, WEST VIRGINIA
Prepared for:
TOLAND MIZELL MOLNAR, LLC
590 MEANS STREET NW, SUITE 200
ATLANTA, GEORGIA 30318
Report Date:
June 4, 2019
Prepared by:
MICHAEL F. DURBIN, CIH
WEST VIRGINIA ASBESTOS INSPECTOR LICENSE NUMBER A1010137, EXPIRES 02/29/2020; ASBESTOS PROJECT
DESIGNER LICENSE NUMBER AD004153, EXPIRES 02/29/2010
DURBIN ENVIRONMENTAL CONSULTANTS, INC.
2201 POTOMAC PLACE
LAWRENCEVILLE, GEORGIA 30043
(770) 601-7791
TABLE OF CONTENTS
PAGE
1. INTRODUCTION 3
2. DISCUSSION AND RESULTS 3
a. Asbestos
b. Lead
c. PCBs/Fluorescent Lights
3. METHODOLOGY 5
4. OBSERVATIONS/CONCLUSIONS 7
5. RECOMMENDATIONS 8
6. REFERENCES 9
APPENDIX
A. Asbestos Bulk Sampling Summary followed by the Laboratory Report and
Representative Photographs of Suspect Asbestos Containing Materials
B. Paint Chip Sample Summary followed by the Laboratory Data and Photographs of Paint
Chip Samples
1. INTRODUCTION
Durbin Environmental Consultants, Inc. (DEC) was retained by Toland Mizell Molnar, LLC, to conduct a targeted hazardous material assessment for suspect asbestos containing materials and lead-based paint at the VA Medical Center, Beckley, West Virginia in support of the Building 14/15 Renovation Project. Michael F. Durbin, CIH, of Durbin Environmental Consultants, Inc., conducted the asbestos and lead in paint material assessment on May 7, 2019. Mr. Durbin is currently accredited as an Asbestos Inspector (License #A1010137, Expires 02/29/2019) and Asbestos Project Designer (License #AD004153, Expires 02/29/20120) through the West Virginia Asbestos Program.
Bulk sample analysis for suspect asbestos containing materials and paint chip sample analysis was performed by SanAir Technologies Laboratory, 1551 Oakbridge Drive, Suite B, Powhatan, VA 23139. SanAir is accredited for asbestos fiber analysis through participation in the National Institute of Standards and Technology (NIST) National Voluntary Laboratory Accreditation Program (NVLAP) and is assigned NVLAP Lab Code 200870-0. San Air utilized the analytical method: EPA/600/R-93/116: "Method for the Determination of Asbestos in Bulk Building Materials” (polarized light microscopy in conjunction with dispersion staining).
SanAir analyzed the paint chip samples by Atomic Absorption Spectrophotometer, Flame, following the EPA Method SW846/M3050B/7000B. SanAir is accredited by the American Industrial Hygiene Association (AIHA) Laboratory Accreditation Program and is a participant in the Environmental Microbiology & Lead Proficiency Analytical Testing Program (EMPAT) and is assigned Lab Number 162952. SanAir is also an Approved Environmental Laboratory by the State of West Virginia, Bureau for Public Health, Office of Environmental Health Services and is assigned license number LT000616 (Expires May 31, 2020).
2. DISCUSSION AND RESULTS
a. VA Beckley, Building 14/15 - Asbestos
The asbestos survey was conducted in accordance with the sampling protocol established in the Environmental Protection Agency’s Asbestos Hazard Emergency Response Act (AHERA 40 CFR, Part 763) for the materials included in this specific survey. The following provides general information and summarizes the potential impact of asbestos containing material during any scheduled renovation project.
Bulk samples were collected from the following suspect asbestos containing materials during this survey:
1. 2’ X 2’ White Ceiling Tile, Small Gouges and Holes (HM #1)
2. 12” X 12” Blue Mottled Floor Tile and Adhesive (HM #2)
3. 18” X 18” Beige Floor Tile and Adhesive (HM #3)
4. 12” X 12” Beige Floor Tile with Brown Streaks and Adhesive (HM #4)
5. Light Brown Covebase and Adhesive (HM #5)
6. Dark Brown Covebase and Adhesive (HM #6)
7. Yellow Carpet Adhesive (HM #7)
8. Drywall, No Joint Compound Present (HM #8)
9. Yellow Batt Insulation (HM #9)
10. Pink Batt Insulation (HM #10)
11. Foil Wrapped Duct Insulation over Glass Fiber (HM #11)
12. Beige Exterior Caulk (HM #12)
13. Stucco-Type Material on Wood Board (HM #13)
None of the collected bulk sample materials contained asbestos by Polarized Light Microscopy (PLM) (reference Appendix A for the Asbestos Bulk Sampling Summary followed by the Laboratory Report and Representative Photographs of Suspect Asbestos Containing Materials).
b. VA Beckley, Building 14/15 - Lead
Paint chip samples were collected from the following representative locations:
1. Beige Paint, Exterior Stucco Walls, Building 14/15, Exterior Walls (Sample # 1415-PC-01)
2. Beige Paint, Exterior Stucco Walls, Building 14/15, Exterior Walls (Sample # 1415-PC-02)
Both of the painted surfaces sampled at VA Beckley, Building 14/15, were less than 0.5% lead by weight via Flame Atomic Absorption Spectrophotometry. Sample 1415-PC-01 and Sample 1415-PC-02 contained less than 0.008% lead by weight and therefore were below the analytical reporting limit (BRL).
Note: Disturbance to any painted item/surface/component shall be done in compliance with the OSHA Construction Industry Standard for Lead (29 CFR 1926.62). The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR
1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (µg) lead per cubic meter (m3) of air determined as an 8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
Refer to Appendix B for the Paint Chip Sample Summary followed by Laboratory Data and Representative Photographs of Paint Chip Samples.
c. VA Beckley, Building 14/15 - PCBs/Fluorescent Lights
The construction date of the VA Beckley, Building 14/15 is unknown. All ballasts installed or manufactured prior to 1978, should be assumed to contain PCBs unless specifically labeled as having no PCBs.
All known or assumed PCB ballasts, capacitors or other PCB articles should be handled in accordance with 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions and State of West Virginia Code 22-18 Hazardous Waste Management Act and State of West Virginia Code 33-20 Waste Management, Division of Water and Waste Management.
All batteries, mercury-containing equipment and bulbs should be handled in accordance with 40 CFR Part 273 Standards for Universal Waste Management and State of West Virginia Code 22- 18 Hazardous Waste Management Act and State of West Virginia Code 33-20 Waste Management, Division of Water and Waste Management.
Refrigerants shall be disposed on in accordance with Section 608 of the Clean Air Act (EPA Refrigerant and Recycling Rule and 40 CFR Part 82 Protection of Stratospheric Ozone) in addition to the State of West Virginia Code 22-18 Hazardous Waste Management Act and State of West Virginia Code 33-20 Waste Management, Division of Water and Waste Management.
Fluorescent lights and high intensity discharge bulbs (HID) and other mercury-containing bulbs are regulated under the Resource Conservation and Recovery Act (RCRA) Universal Waste Rule (UWR) and Subtitle C hazardous waste regulations. Accordingly, all bulbs should be disposed of or recycled in accordance with the current policy of the VA Medical Center, Beckley, West Virginia.
3. METHODOLOGY
Asbestos Sampling Protocol
The inspector sampled all suspect ACM in accessible areas. In order for a group of homogeneous materials to be considered as non-asbestos containing, all samples from that specific homogeneous material must be analyzed and determined to be non-asbestos containing or less than or equal to 1% asbestos.
Representative, randomly selected samples were collected from each homogeneous area of suspect asbestos-containing material. For purposes of this report, the homogeneous area is physically defined as all material with the same visual appearance, texture and hardness.
The minimum number of samples collected for each homogeneous area (or material), if present, is as follows:
1. Friable Spray-applied or Trowel-applied Material
a. Less than or equal to 1000 square feet (S.F.) = 3 samples
b. Greater than 1000 S.F. and less than or equal to 5000 S.F. = 5 samples.
c. Greater than 5000 S. F. = 7 samples
2. Pipe and Duct Insulation
Three samples per homogeneous area of insulation were taken unless it was a confirmation sample.
3. Elbows, Valves, Fittings and Connection Mud
Three representative samples were taken from each representative type of insulated elbow, valve, fitting and connecting mud unless it was a confirmation sample.
4. Boiler, Tanks and Furnaces
A minimum of 3 samples per unit was collected.
5. Patchwork Patchwork is defined as a patch or repair to existing material based on the following quantities:
a. Surfacing material patches are limited to a maximum of 6 S. F.
b. Pipe and duct insulation patches are limited to a maximum of 6 L. F. or 6
S. F.
c. Boiler, tanks and furnace patches are limited to 6 S.F. maximum.
If the patchwork exceeded the limits prescribed above, the sampling protocol resorted back to the homogeneous area descriptions in items 1-4. If a material qualifies as patchwork, a single sample was collected per patch.
6. Ceiling or Acoustical Tile
a. Minimum of 3 Samples
7. Miscellaneous Friable Material (INCLUDED DRYWALL & JOINT
COMPOUND)
a. 3 Samples
8. Non-friable Material
Non-friable materials for purposes of this survey would include material such as floor tiles and mastic/adhesive, linoleum floor covering, interior/exterior caulks, flooring felt (if still under floor tile), roofing materials, miscellaneous cementitious material such as wall or ceiling panels, caulking or sealant, or window glazing.
a. Minimum of 2 samples
Lead-Based Paint (LBP) Sampling Protocol
Paint chips containing lead concentrations at or above 0.5 percent by weight are considered positive for lead, based on EPA and Department of Housing and Urban Development (HUD) guidelines for Target Housing and Child Occupied Facilities.
The inspector collected paint chip samples from representative surfaces and components likely to be impacted by any renovation project and compared them against the HUD definition for Lead- Based Paint (LBP) of 0.5 % by weight. Individual sample results are presented in tabular form in Appendix B.
The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR 1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (µg) lead per cubic meter (m3) of air determined as an 8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
4. OBSERVATIONS/CONCLUSIONS
VA Beckley, Building 14/15 - Asbestos
None of the collected bulk sample materials contained asbestos by Polarized Light Microscopy (PLM) (reference Appendix A for the Asbestos Bulk Sampling Summary followed by the Laboratory Report and Representative Photographs of Suspect Asbestos Containing Materials).
VA Beckley, Building 14/15 - Lead
Both of the painted surfaces sampled at VA Beckley, Building 14/15, were less than 0.5% lead by weight via Flame Atomic Absorption Spectrophotometry. Sample 1415-PC-01 and Sample 1415-PC-02 contained less than 0.008% lead by weight and therefore were below the analytical reporting limit (BRL).
Note: Disturbance to any painted item/surface/component shall be done in compliance with the OSHA Construction Industry Standard for Lead (29 CFR 1926.62). The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR
1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (µg) lead per cubic meter (m3) of air determined as an 8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
Refer to Appendix B for the Paint Chip Sample Summary followed by Laboratory Data and Representative Photographs of Paint Chip Samples.
VA Beckley, Building 14/15 - PCBs/Fluorescent Lights
The construction date of the VA Beckley, Building 14/15 is unknown. All ballasts installed or manufactured prior to 1978, should be assumed to contain PCBs unless specifically labeled as having no PCBs.
All known or assumed PCB ballasts, capacitors or other PCB articles should be handled in accordance with 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions and State of West Virginia Code 22-18 Hazardous Waste Management Act and State of West Virginia Code 33-20 Waste Management, Division of Water and Waste Management.
All batteries, mercury-containing equipment and bulbs should be handled in accordance with 40 CFR Part 273 Standards for Universal Waste Management and State of West Virginia Code 22- 18 Hazardous Waste Management Act and State of West Virginia Code 33-20 Waste Management, Division of Water and Waste Management.
Refrigerants shall be disposed on in accordance with Section 608 of the Clean Air Act (EPA Refrigerant and Recycling Rule and 40 CFR Part 82 Protection of Stratospheric Ozone) in addition to the State of West Virginia Code 22-18 Hazardous Waste Management Act and State of West Virginia Code 33-20 Waste Management, Division of Water and Waste Management.
Fluorescent lights and high intensity discharge bulbs (HID) and other mercury-containing bulbs are regulated under the Resource Conservation and Recovery Act (RCRA) Universal Waste Rule (UWR) and Subtitle C hazardous waste regulations. Accordingly, all bulbs should be disposed of or recycled in accordance with the current policy of the VA Medical Center, Beckley, West Virginia.
5. RECOMMENDATIONS
A. The asbestos containing material survey report shall be maintained at the job site during performance of the construction activities. At least ten (10) working days advanced written NESHAPS Notification to the following is required only if demolition (Demolition is defined in 40 CFR Part 61, Subpart M, as the wrecking or taking out any load-supporting structural member of a facility together with any related handling operations or intentional burning of any facility.) activities are required: (1) State of West Virginia, Department of Environmental Protection, Division of Air Quality, 601 57th Street, Charleston, West Virginia 25304, Attention Asbestos Program Manager, Phone 304-926-0475; (2) U.S. Environmental Protection Agency, Region III, 1650 Arch Street, Philadelphia, PA 19103-2029, Attention
Asbestos Coordinator (3LC62), Phone 215-814-3244; (3) State of West Virginia, Department of Environmental Protection, Division of Water & Waste Management Section, 601 57th Street, Charleston, West Virginia 25301, Attention Asbestos Coordinator, Phone 304-926- 0499; and (4) West Virginia Bureau of Public Health, Environmental Health Services, Asbestos Compliance Program, 350 Capitol Street, Room 313, Charleston, West Virginia 25301-3713, Attention Asbestos Coordinator, Phone 304-558-2981.
B. Communication of this asbestos survey report results should be presented in accordance with the OSHA 29 CFR 1926.1101 Asbestos Standard to all personnel who may enter or perform work in the VA Medical Center, Building 14/15, Beckley, West Virginia.
C. The lead survey report shall be maintained at the job site during performance of the construction activities.
D. Disturbance of painted surfaces should be performed in accordance with the OSHA Lead
Standard (29 CFR 1926.62). Waste generated by disturbance of painted surfaces should be subjected to Toxicity Characteristic Leaching Procedure (TCLP) testing to determine leachable lead concentrations. If leachable concentrations of lead in construction waste are determined by TCLP testing, those materials should be disposed of in accordance with 40 CFR Part 260 to 271, and the State of West Virginia Code 22-18 Hazardous Waste Management Act and State of West Virginia Code 33-20 Waste Management, Division of Water and Waste Management.
E. Remove and dispose of all PCB ballasts, if present, in accordance with 40 CFR Part 761
Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions, and other applicable Federal, State and Local Regulations.
F. Remove and dispose of (or recycle) all batteries, mercury thermostats and mercury vapor light fixtures in accordance with 40 CFR Part 273 Standards for Universal Waste Management and other applicable Federal, State and Local Regulations.
6. REFERENCES
1. Guidance for Controlling Asbestos-Containing Materials in Buildings”
(Purple Book). EPA 560/5-85-024. Office of Pesticides and Toxic Substances Washington, DC 20460.
2. 40 CFR, Part 763, Asbestos Hazard Emergency Response Act
3. 40 CFR, Part 763, Asbestos School Hazard Abatement Reauthorization Act
4. 40 CFR, Part 61, Subpart M Asbestos
5. 29 CFR Part 1926.1101 Asbestos
6. 29 CFR Part 1926.62 Lead
7. HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (Most recent issue)
8. 40 CFR Part 260 General Hazardous Waste Management.
9. 40 CFR Part 261 Identification and Listing of Hazardous Waste.
10. 40 CFR Part 262 Standards Applicable to Generators of Hazardous Waste.
11. 40 CFR Part 263 Standards Applicable to Transporters of Hazardous Waste.
12. 40 CFR Part 268 Land Disposal Restrictions.
13. 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions.
14. 40 CFR Part 273 Standards for Universal Waste Management
15. State of West Virginia Asbestos Licensure Law 16-32; 64CSR63 – West Virginia
Asbestos Licensing Rule
16. State of West Virginia Code 22-18 Hazardous Waste Management Act and State of West
Virginia Code 33-20 Waste Management, Division of Water and Waste Management
If you have any questions or comments regarding this report, please do not hesitate to call.
Sincerely, Durbin Environmental Consultants, Inc.
Michael F. Durbin, CIH Michael F. Durbin, CIH WEST VIRGINIA ASBESTOS INSPECTOR LICENSE NUMBER A1010137, EXPIRES 02/29/2020; ASBESTOS PROJECT
DESIGNER LICENSE NUMBER AD004153, EXPIRES 02/29/2010
President
APPENDIX A
Asbestos Bulk Sampling Summary Followed by the Laboratory Data and Representative Photographs of Suspect Asbestos Containing Materials
Sample Number
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
1415-CT1-
2’ X 2’ White Ceiling Tile, Small Gouges and Holes NAD N/A See Lab
Report Building 14/15, Room 14-119
1415-CT1-
2’ X 2’ White Ceiling Tile, Small Gouges and Holes NAD N/A See Lab
Report Building 14/15, Room 15-117 1
1415-CT1-
2’ X 2’ White Ceiling Tile, Small Gouges and Holes NAD N/A See Lab
Report Building 14/15, Corridor Outside Room 15-103
1415-FT1-
12” X 12” Blue Mottled Floor Tile and Adhesive NAD N/A See Lab
Report Building 14/15, Conference Room 15-117
1415-FT1-
12” X 12” Blue Mottled Floor Tile and Adhesive NAD N/A See Lab
Report Building 14/15, Conference Room 15-117
1415-FT1-
12” X 12” Blue Mottled Floor Tile and Adhesive NAD N/A See Lab
Report Building 14/15, Conference Room 15-117
1415-FT2-
18” X 18” Beige Floor Tile and
Adhesive NAD N/A See Lab
Report Building 14/15, Corridor Outside Room 15-103
1415-FT2-
18” X 18” Beige Floor Tile and
Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-111 3
1415-FT2-
18” X 18” Beige Floor Tile and
Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-111
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
1415-FT3-
12” X 12” Beige Floor Tile with
Brown Streaks and Adhesive
NAD N/A See Lab Report
Building 14/15, Room 15-121
1415-FT3-
12” X 12” Beige Floor Tile with
Brown Streaks and Adhesive
NAD N/A See Lab Report
Building 14/15, Room 15-121 4
1415-FT3-
12” X 12” Beige Floor Tile with
Brown Streaks and Adhesive
NAD N/A See Lab Report
Building 14/15, Room 14-104
1415-CB1-
Light Tan Covebase and Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-103
1415-CB1-
Light Tan Covebase and Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-111 5
1415-CB1-
Light Tan Covebase and Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-103B
1415-CB2-
Dark Brown Covebase and
Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-104B
1415-CB2-
Dark Brown Covebase and
Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-104B 6
1415-CB2-
Dark Brown Covebase and
Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-104B
1415-CA1-
Yellow Carpet Adhesive NAD N/A See Lab
Report
Room 14-119 7
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
1415-CA1-
Yellow Carpet Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-119
1415-CA1-
Yellow Carpet Adhesive NAD N/A See Lab
Report Building 14/15, Room 14-119 7
1415-
DWJC-01
Drywall, No Joint Compound Present NAD N/A See Lab
Report Building 14/15, Room 14-119
1415-
DWJC-02
Drywall, No Joint Compound Present NAD N/A See Lab
Report Building 14/15, Room 15-116 8
1415-
DWJC-03
Drywall, No Joint Compound Present NAD N/A See Lab
Report Building 14/15, Room 15-117
1415-
BATT1-01
Yellow Batt Insulation NAD N/A See Lab
Report Building 14/15, Room 14-119
1415-
BATT1-02
Yellow Batt Insulation NAD N/A See Lab
Report Building 14/15, Room 15-116 9
1415-
BATT1-03
Yellow Batt Insulation NAD N/A See Lab
Report Building 14/15, Room 15-117
1415- BATT2-01 Pink Batt Insulation NAD N/A See Lab
Report Building 14/15, Crawl Space
1415- BATT2-02 Pink Batt Insulation NAD N/A See Lab
Report Building 14/15, Crawl Space 10
1415- BATT2-03 Pink Batt Insulation NAD N/A See Lab
Report
Crawl Space
Description Asbestos Present
Friable Non- Asbestos Material Present
Sample Location
HM
1415-DI1-
Foil Wrapped Duct Insulation over Glass
Fiber NAD N/A See Lab
Report Building 14/15, Room 14-119
1415-DI1-
Foil Wrapped Duct Insulation over Glass
Fiber NAD N/A See Lab
Report Building 14/15, Room 15-116 11
1415-DI1-
Foil Wrapped Duct Insulation over Glass
Fiber NAD N/A See Lab
Report Building 14/15, Room 15-117
1415-EC-01 Beige Exterior Caulk NAD N/A See Lab Report
Building 14/15, Exterior of Building
1415-EC-02 Beige Exterior Caulk NAD N/A See Lab Report
Building 14/15, Exterior of Building
1415-EC-03 Beige Exterior Caulk NAD N/A See Lab Report
Building 14/15, 1415-EB-01 Stucco-Type Material on Wood Board NAD N/A See Lab
Report
Building 14/15, 1415-EB-02 Stucco-Type Material
Report
Building 14/15, 1415-EB-03 Stucco-Type Material
Report
Building 14/15, 1415-EB-04 Stucco-Type Material
Report
Building 14/15, Exterior of Building
1415-EB-05 Stucco-Type Material on Wood Board NAD N/A See Lab
Report
Building 14/15, 1415-EB-06 Stucco-Type Material
Report
Building 14/15, 1415-EB-07 Stucco-Type Material
Report
Building 14/15, NAD – No Asbestos Detected; N/A – Not Applicable
Representative Photographs of Suspect Asbestos Containing Materials
1. 2’ X 2’ White Ceiling Tile, Small Gouges and Holes (HM #1)
2. 12” X 12” Blue Mottled Floor Tile and Adhesive (HM #2)
3. 18” X 18” Beige Floor Tile and Adhesive (HM #3)
4. 12” X 12” Beige Floor Tile with Brown Streaks and Adhesive (HM #4)
5. Light Tan Covebase and Adhesive (HM #5)
6. Dark Brown Covebase and Adhesive (HM #6)
7. Yellow Carpet Adhesive (HM #7)
8. Drywall, No Joint Compound Present (HM #8)
9. Yellow Batt Insulation (HM #9)
10. Pink Batt Insulation (HM #10)
11. Foil Wrapped Duct Insulation over Glass Fiber (HM #11)
12. Beige Exterior Caulk (HM #12)
13. Stucco-Type Material on Wood Board (HM #13)
APPENDIX B
Paint Chip Sample Summary Table Followed by Laboratory Data and Representative Photographs of Paint Chip Samples
Collection Date
Sample Number
Description Location Analytical Method
Percent Lead by Weight
(wt%)
05/07/2019 1415-PC-01
Beige Paint, Exterior Stucco Walls
Building 14/15, Exterior Walls AAS <0.008
05/07/2019 1415-PC-02
Beige Paint, Exterior Stucco Walls
Exterior Walls AAS <0.008
BRL: Not Detected at the Reporting Limit
Representative Photographs of Paint Chip Samples
1. Beige Paint, Exterior Stucco Walls, Building 14/15, Exterior Walls (Sample # 1415-PC-01)
2. Beige Paint, Exterior Stucco Walls, Building 14/15, Exterior Walls (Sample # 1415-PC-02)