S02 517-19-302_Addendum 1 - Specs Vol II - 10-23.pdf

PDF 3 MB Posted

Attached to
Z1DA--Renovate Medical Surgical Ward for Patient Privacy
Solicitation number
36C24523B0003
Issued by

About this file

This is a solicitation for the renovation of a medical surgical ward to provide patient privacy at the Beckley VA Medical Center in Beckley, West Virginia. The solicitation is for design-bid-build construction services including demolition, new construction, and renovation work. The solicitation number is 36C24523B0003 and was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 5. The work includes upgrading patient rooms, toilet rooms, corridors, and support spaces to meet privacy requirements. The estimated award date is in late 2023 and the period of performance is 420 calendar days from NTP.

View the file

Other files

File Type Posted
36C24523B0003 0007.docx DOCX document
S06 drawing FA601.pdf PDF
S06 Drawing E-002.pdf PDF
S06 Follow-Up RFIs 06.16.2023.pdf PDF
S02 Drawing Part6_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing Part7_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing DVA_Clinical_Addition_II_A-22.pdf PDF
36C24523B0003 0006.docx DOCX document
S05 Answers for Reno Med Surg RFI .pdf PDF
S02 Drawing Part8_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawings Part9_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing Part11_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing Part3_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing DVA_Clinical_Addition_II_A-21.pdf PDF
S02 Drawing 32 01 H10.pdf PDF
S02 Drawing Part1_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing 32 01 H9.pdf PDF
S02 Drawing Part2_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing Part5_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing DVA_Clinical_Addition_II_A-09.pdf PDF
S02 517-19-302_Addendum 1 - Specs Vol III - 26-28.pdf PDF
S02 517-19-302_Addendum 1 - Specs Vol I - 00 -09.pdf PDF
S02 Drawing Part4_517-19-302_Addendum 1 - Drawings.pdf PDF
S02 Drawing Part10_517-19-302_Addendum 1 - Drawings.pdf PDF
36C24523B0003 0005.docx DOCX document
36C24523B0003 0004.docx DOCX document
36C24523B0003 0003.docx DOCX document
36C24523B0003 0002.docx DOCX document
S04 Pre-Bid Site Visit Sign In.pdf PDF
36C24523B0003 0001.docx DOCX document
S04 Pre Bid Agenda Renovate Med Surg.pdf PDF
S02 Final Contract Docs - Drawings_82-91.pdf PDF
S02 Final Doc - Specs - Volume II .pdf PDF
S02 Final Contract Docs - Drawings_1-12.pdf PDF
S02 Final Doc - Specs - Volume I .pdf PDF
S02 Final Doc - Specs - Volume III .pdf PDF
S02 Final Contract Docs - Drawings_13-28.pdf PDF
S02 Final Contract Docs - Drawings_38-43.pdf PDF
S02 Final Contract Docs - Drawings_57-64.pdf PDF
S02 Final Contract Docs - Drawings_44-56.pdf PDF
S02 Final Contract Docs - Drawings_65-72.pdf PDF
S02 SOW 517-19-302 Renovate MedSurg for Patient Privacy FINAL .pdf PDF
S02 Final Contract Docs - Drawings_92-98.pdf PDF
S02 Wage Determination 1-5-23 .pdf PDF
36C24523B0003.docx DOCX document
S02 Final Contract Docs - Drawings_73-81.pdf PDF
S02 Final Contract Docs - Drawings_29-37.pdf PDF
S02 Final Contract Docs - Drawings_99-end.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FINAL CONTRACT

DOCUMENT SUBMISSION

SPECIFICATIONS

VOLUME II

DIV 10 – DIV 23

RENOVATE MEDICAL SURGICAL WARD FOR PATIENT PRIVACY Project

No. 517-19-302

Beckley VA Medical Center

Beckley, WV

1040 Kings Highway North

Suite 700

Cherry Hill, New Jersey 08034

(856) 429-4000

June 2, 2023

Department of Veterans Affairs VA Project #517-19-302

Beckley VAMC Renovate Medical Surgical Ward for Patient Privacy

Beckley, WV Final Contract Document Submission: 06/02/23

05-01-22

00 01 10-1

DEPARTMENT OF VETERANS AFFAIRS

VHA MASTER SPECIFICATIONS

TABLE OF CONTENTS

Section 00 01 10

SECTION NO. DIVISION AND SECTION TITLES DATE

DIVISION 00 - SPECIAL SECTIONS

00 01 15 List of Drawing Sheets 05-20

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 General Requirements 11-21

01 32 16.15 Project Schedules (Small Projects – Design/Bid/Build 11-21

01 33 23 Shop Drawings, Product Data, and Samples 06-21

01 33 23.10 Submittal Register

01 35 26 Safety Requirements 11-21

01 42 19 Reference Standards 11-20

01 45 00 Quality Control 02-21

01 45 29 Testing Laboratory Services 11-18

01 45 35 Special Inspections 06-21

01 45 35.10 Attach A - Schedule

01 45 35.20 Attach B – Special Inspections

01 58 16 Temporary Interior Signage 07-15

01 74 19 Construction Waste Management 04-22

01 81 13 Sustainable Construction Requirements 10-17

01 91 00 General Commissioning Requirements 04-22

DIVISION 02 – EXISTING CONDITIONS

02 41 00 Demolition 08-17

02 82 11 Traditional Asbestos Abatement 01-21

02 82 13.13 Glovebag Asbestos Abatement 01-21

DIVISION 03 – CONCRETE

03 30 53 (Short-Form) Cast-in-Place Concrete 01-21

DIVISION 04 – MASONRY

04 05 13 Masonry Mortaring 10-17

04 20 00 Unit Masonry 08-17

DIVISION 05 – METALS

05 12 00 Structural Steel Framing 11-18

05 50 00 Metal Fabrications 08-18

05 51 00 Metal Stairs 01-21

00 01 10-2

05 52 14 Non-Penetrating Pipe and Tube Railings

DIVISION 06 – WOOD, PLASTICS AND COMPOSITES

06 06 60 Translucent Resin Panel Systems

06 10 00 Rough Carpentry 10-17

06 20 00 Finish Carpentry 01-21

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 01 50.19 Preparation for Re-Roofing 01-21

07 21 13 Acoustical Insulation 01-21

07 84 00 Firestopping 01-21

07 92 00 Joint Sealants 04-22

07 95 13 Expansion Joint Cover Assemblies 01-21

DIVISION 08 - OPENINGS

08 11 13 Hollow Metal Doors and Frames 01-21

08 14 00 Interior Wood Doors 01-21

08 31 13 Access Doors and Frames 04-22

08 71 00 Door Hardware 05-22

08 71 13 Automatic Door Operators 01-21

08 80 00 Glazing 01-21

DIVISION 09 – FINISHES

09 05 16 Subsurface Preparation for Floor Finishes 01-21

09 22 16 Non-Structural Metal Framing 06-18

09 29 00 Gypsum Board 04-20

09 30 13 Ceramic/Porcelain Tiling 01-21

09 51 00 Acoustical Ceilings 12-18

09 65 13 Resilient Base and Accessories 01-21

09 65 16 Resilient Sheet Flooring 05-18

09 65 19 Resilient Tile Flooring 05-18

09 66 16 Terrazzo Floor Tile 01-21

09 67 23 Resinous Urethane and Epoxy Mortar Flooring (Addendum

1)

09 72 31 Polypropylene Fabric Wall Covering 01-21

09 91 00 Painting 01-21

DIVISION 10 – SPECIALTIES

10 11 13 Chalkboards and Markerboards 01-21

10 11 23 Tackboards 01-21

10 14 00 Signage 01-21

10 21 13 Toilet Compartments 01-21

10 21 23 Cubicle Curtain Tracks 01-21

00 01 10-3

10 26 00 Wall and Door Protection 01-21

10 28 00 Toilet, Bath, and Laundry Accessories 01-21

10 44 13 Fire Extinguisher Cabinets 08-18

10 51 13 Phenolic Lockers

DIVISION 11 – EQUIPMENT

11 05 12 General Motor Requirements for Equipment 01-21

11 05 13 Hospital Grade Edgelit HDTV and Wall Mounts

11 73 00 Ceiling Mounted Patient Lift System 08-20

DIVISION 12 – FURNISHINGS

12 24 00 Window Shades 08-17

12 36 00 Countertops 12-18

DIVISION 13 - SPECIAL CONSTRUCTION

13 05 41 Seismic Restraint Requirements for Non-Structural

Components

01-21

DIVISION 21- FIRE SUPPRESSION

21 08 00 Commissioning of Fire Suppression System 11-16

21 13 13 Wet-Pipe Sprinkler Systems (Addendum 1) 06-15

DIVISION 22 – PLUMBING

22 05 11 Common Work Results for Plumbing 09-20

22 05 23 General-Duty Valves for Plumbing Piping 09-20

22 07 11 Plumbing Insulation 09-19

22 08 00 Commissioning of Plumbing Systems 11-16

22 11 00 Facility Water Distribution 05-21

22 13 00 Facility Sanitary and Vent Piping 09-20

22 40 00 Plumbing Fixtures 09-15

22 62 00 Vacuum Systems for Laboratory and Healthcare Facilities 09-15

22 63 00 Gas Systems for Laboratory and Healthcare Facilities 09-15

DIVISION 23 – HEATING, VENTILATING, AND AIR

CONDITIONING (HVAC)

23 05 11 Common Work Results for HVAC (Addendum 1) 04-22

23 05 12 General Motor Requirements for HVAC and Steam

Generation Equipment

02-20

23 05 41 Noise and Vibration Control for HVAC Piping and

Equipment (Addendum 1)

02-20

23 05 93 Testing, Adjusting, and Balancing for HVAC 02-20

23 07 11 HVAC and Boiler Plant Insulation 02-20

23 08 00 Commissioning of HVAC Systems 04-22

00 01 10-4

23 09 23 Direct-Digital Control System for HVAC 09-11

23 21 13 Hydronic Piping 02-20

23 21 23 Hydronic Pumps 02-20 23 22 13 Steam and Condensate Heating Piping (Addendum 1) 02-20

23 23 00 Refrigerant Piping 02-20

23 25 00 HVAC Water Treatment 02-20

23 31 00 HVAC Ducts and Casings 02-20

23 34 00 HVAC Fans 02-20

23 36 00 Air Terminal Units 02-20

23 37 00 Air Outlets and Inlets 02-20

23 40 00 HVAC Air Cleaning Devices 03-20

23 74 13 Packaged, Outdoor, Central-Station Air-Handling Units 03-20

23 81 43 Air-Source Unitary Heat Pumps 03-20

23 82 16 Air Coils 03-20

DIVISION 26 – ELECTRICAL

26 05 11 Requirements for Electrical Installations 01-16

26 05 19 Low-Voltage Electrical Power Conductors and Cables 01-17

26 05 26 Grounding and Bonding for Electrical Systems 01-17

26 05 33 Raceway and Boxes for Electrical Systems 01-18

26 05 73 Overcurrent Protective Device Coordination Study 01-18

26 08 00 Commissioning of Electrical Systems 11-16

26 09 23 Lighting Controls 01-18

26 24 16 Panelboards 01-18

26 27 26 Wiring Devices 01-18

26 29 11 Motor Controllers 01-18

26 29 21 Enclosed Switches and Circuit Breakers 01-17

26 51 00 Interior Lighting 01-18

DIVISION 27 – COMMUNICATIONS

27 05 11 Requirements for Communications Installations 09-19

27 05 26 Grounding and Bonding for Communications Systems 06-15

27 05 33 Raceways and Boxes for Communications Systems 10-18

27 08 00 Commissioning of Communications Systems 11-16

27 10 00 Control, Communication and Signal Wiring 06-15

27 15 00 Communications Structured Cabling 01-16

27 41 31 Master Antenna Television Equipment and Systems 06-15

27 51 16 Public Address and Mass Notification Systems 10-18

27 52 23 Nurse Call and Code Blue Systems 10-18

DIVISION 28 – ELECTRONIC SAFETY AND SECURITY

28 05 00 Common Work Results for Electronic Safety and Security 04-18

28 05 13 Conductors and Cables for Electronic Safety and

Security

10-18

28 08 00 Commissioning of Electronic Safety and Security Systems 11-16

00 01 10-5

28 13 00 Physical Access Control System 10-11

28 31 00 Fire Detection and Alarm 10-11

00 01 10-6

Page Intentionally Left Blank

10 11 13 - 1

SECTION 10 11 13

CHALKBOARDS AND MARKERBOARDS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies markerboards.

1.2 QUALITY ASSURANCE

A. Provide boards that are the products of a single manufacturer, who has provided units as specified for a minimum of three (3) years.

1.3 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA

AND SAMPLES.

B. Shop Drawings: Identifying all parts by name and material and showing design, construction, installation, anchorage and relation to adjacent construction.

C. Manufacturer's Literature and Data:

1. Markerboard.

D. Samples:

1. Markerboard writing surface, 152 x 152 mm (6 x 6 inches), each color, and texture mounted on backing.

2. Frame material, 305 mm (6 inch) length.

E. Manufacturer’s qualifications.

1.4 WARRANTY

A. Construction Warranty: Comply with FAR clause 52.246-21, “Warranty of

Construction”.

1.5 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. American National Standards (ANSI):

Z97.1-09(R2010).........Safety Glazing Materials Used in Buildings -

Safety Performance Specifications and Methods of Test

C. ASTM International (ASTM):

C1048-12................Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass

10 11 13 - 2

D7803-19................Practice for Preparation of Zinc (Hot-Dip

Galvanized) Coated Iron and Steel Product and

Hardware Surfaces for Powder Coating

D. Code of Federal Regulation (CFR):

40 CFR 59...............Determination of Volatile Matter Content, Water

Content, Density Volume Solids, and Weight

Solids of Surface Coating

E. National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500-06..............Metal Finishes Manual

PART 2 - PRODUCTS

2.1 MARKERBOARD

A. Basis of Design: Peter Pepper Products, ClinArt Writing Surface, Model

RG1824, clear glass marker board with powder coated steel perimeter frame, marker eraser holder and removable graphic board with custom graphic as supplied by Owner (VA).

B. Provide factory assembled unit sized as indicated on Drawings, complete as one (1) piece without joints.

C. Frame: Steel.

D. Provide surface such that dry erase markings are removable with felt eraser or dry cloth without ghosting.

E. Provide face fabricated from tempered glass material.

2.2 MATERIALS

A. Writing Surface:

1. Provide markerboard writing surface composed of clear glass.

B. Steel:

1. Steel frame fabrications to be manufacturer’s standard profile and thickness with powder coated finish on all surfaces.

2. Provide straight, single lengths.

3. Miter corners and assemble units with tight hairline closure.

C. Glass:

1. Provide tempered glass in accordance with ANSI Z97.1 and conform to

ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type

I, Class I (clear).

D. Removable Graphic Board:

1. Manufacturer’s standard rigid board material with custom graphic using print method and color pallete as necessary to satisfy graphic representation as supplied by Owner (VA).

10 11 13 - 3

E. Mounting Hardware:

1. Provide manufactuer’s standard clips and fasteners as necessary to mount boards in a concealed fashion.

2.3 GENERAL FINISH REQUIREMENTS

A. Comply with NAAMM’s AMP 500 Series for Architectural and Metal Products for recommendations for applying and designating finishes.

B. Baked-Enamel or Powder-Coat Finish: AAMA 2603, except with a minimum dry film thickness of 1.5 mils (0.04 mm). Comply with coating manufacturer's written instructions for cleaning, conversion coating, and applying and baking finish

C. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

D. Appearance of Finished Work: Noticeable variations in same piece are unacceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved samples and are assembled or installed to minimize contrast.

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Install units in accordance with the manufacturer's installation instructions with concealed fasteners.

B. Verify partitions have received blocking and reinforcement before installation of markerboards.

C. Assemble units in accordance with manufacturer’s written instructions.

D. Grounds Designed to Receive Clips for Snap-On Trim: Continuous and secured 305 mm (12 inches) on center.

3.2 CLEANING

A. Clean in accordance with manufacturers’ written instructions.

B. Touch up factory-applied finishes to restore damaged or soiled areas.

- - - E N D - - -

10 11 13 - 4

10 11 23 - 1

SECTION 10 11 23

TACKBOARDS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies bulletin boards which include tackboards and related items.

1.2 QUALITY ASSURANCE

A. Provide bulletin boards that are the product of one (1) manufacturer that has provided bulletin boards as specified for a minimum of three

(3) years.

1.3 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA

AND SAMPLES.

B. Shop Drawings: Identifying all parts by name and material and showing design, construction, installation, anchorage and relation to adjacent construction.

C. Manufacturer's Literature and Data:

1. Bulletin board.

D. Samples:

1. Tackboard material, 305 x 305 mm (6 x 6 inches), each color, mounted on backing.

2. Frame material, 305 mm (6 inch) length.

E. Manufacturer’s qualifications.

1.4 WARRANTY

A. Construction Warranty: Comply with FAR clause 52.246-21, “Warranty of

Construction”.

1.5 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. American Architectural Manufacturers Association (AAMA):

611-14..................Anodized Architectural Aluminum

2603-13.................Voluntary Specification, Performance

Requirements and Test Procedures for Pigmented

Organic Coatings on Aluminum Extrusions and

Panels

10 11 23 - 2

C. American National Standards Institute (ANSI):

Z97.1-09................Safety Glazing Materials Used in Buildings -

Safety Performance Specifications and Methods of Test

D. ASTM International (ASTM):

B221 -14................Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Shapes and Tubes

B221M-13................Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Shapes and Tubes (Metric)

B429/B429M-10(R2012)....Aluminum-Alloy Extruded Structural Pipe and

Tube

C208-12.................Cellulosic Fiber Insulation Board

C1048-12................Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass

F104-03(R2009)..........Nonmetallic Gasket Materials

E. Code of Federal Regulation (CFR):

40 CFR 59...............Determination of Volatile Matter Content, Water

Content, Density Volume Solids, and Weight

Solids of Surface Coating

F. Composite Panel Association (CPA):

A208.1-09...............Particleboard

A135.4-12...............Basic Hardboard

G. National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500 Series..........Metal Finishes Manual

AMP 501.................Finishes for Aluminum

PART 2 - PRODUCTS

2.1 BULLETIN BOARD (TS-1)

A. Provide tackable, bulletin boards as indicated in Finish Material

Schedule on Drawings that consist of a tackboard, snap on aluminum frame and grounds.

2.2 MATERIALS

A. Hardboard: ANSI A135.4, tempered.

B. Fiberboard: ASTM C208.

C. Particleboard: ANSI A208.1, Grade M-1.

D. Hardwood Plywood: HPVA HP-1.

E. Natural-Cork Sheet: Seamless, single-layer, compressed fine-grain cork sheet; bulletin board quality; face sanded for natural finish.

10 11 23 - 3

F. Fabric Covering: ASTM E84, Class A flame spread rating. Biobased, stain resistant, antibacterial, polypropylene fabric.

1. Weight: 10.7 oz/linear yard minimum.

2. Fabric easily cleanable with water/solvent and bleach.

G. Extruded-Aluminum Bars and Shapes: ASTM B221M (ASTM B221), Alloy 6063.

H. Fasteners: Provide screws, bolts, and other fastening devices made from same material as items being fastened, except provide hot-dip galvanized, stainless-steel, or aluminum fasteners for exterior applications. Provide types, sizes, and lengths to suit installation conditions. Provide security fasteners where exposed to view.

I. Adhesives:

1. Adhesives for Field Application: Mildew-resistant, nonstaining adhesive for use with specific type of panels, sheets, or assemblies; and for substrate application; as recommended in writing by visual display unit manufacturer.

2. Adhesives to have VOC content of 50 g/L or less when calculated according to 40 CFR 59 (EPA Method 24).

2.3 COMPONENTS

A. Tackboard: Cork face, 6 mm (1/4-inch) thick, wrapped with fabric and factory laminated to a hardboard or particleboard backing.

B. Frames (Trim): Extruded aluminum, 1.5 mm (0.060-inch) thick, snap-on type, approximate face width 44 mm (1-3/4 inch), depth and configuration as required to return to wall and engage clips.

C. Display Rail: Snap-on type, same materials as frames, approximate face width 25 mm (1 inch) with 6 mm (1/4-inch) thick cork insert.

D. Mullions: Snap-on type, same material and face width as frames, designed to finish flush with frame.

E. Grounds: Continuous zinc-coated (galvanized) steel or extruded aluminum members designed to support the tackboard and clips for snap-on frames, and map rail.

F. Clips: Manufacturer's standard as required to support frame, mullions, and display rail.

G. Provide bulletin boards 3657 mm (12 feet) or less in length in one (1) piece. Provide larger units with one (1) joint at center. Fabricate joints with metal spline, with faces in same plane and edges that touch along entire length.

10 11 23 - 4

2.4 FABRICATION

A. Fabricate bulletin boards to dimensions indicated on construction documents, and as specified for dimensions, design, and thickness and finish of materials.

B. Provide metals and shapes of thickness and reinforcement required to produce flat surfaces and to impart strength.

C. Fabricate frames with reinforced corners, mitered to a hairline fit, with no exposed fasteners.

D. Grind metal edges smooth.

2.5 GENERAL FINISH REQUIREMENTS

A. Comply with NAAMM AMP 500 Series for recommendations for applying and designating finishes.

B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

C. Appearance of Finished Work: Noticeable variations in same piece are unacceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved samples and are assembled or installed to minimize contrast.

2.6 ALUMINUM FINISHES

A. Clear Anodic Finish: AAMA 611, AA-M12C22A31, Class II, 0.010 mm

(0.4 mil) or thicker.

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Install units in accordance with the manufacturer's installation instructions with concealed fasteners.

B. Inspect surfaces to receive units. Verify reinforcement and blocking has been provided in partitions before installation.

C. Install units as specified by the manufacturer.

D. Grounds Designed to Receive Clips for Snap-On Trim: Continuous and be secured 305 mm (12 inches) on center.

E. Miter trim at corners, conceal fasteners. Modify trim as required to conform to surrounding construction details.

3.2 CLEANING

A. Clean tackboards in accordance with manufacturer’s written instructions.

B. Touch-up factory applied finishes restoring damaged or soiled areas.

10 14 00 - 1

SECTION 10 14 00

SIGNAGE

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies interior signage for room numbers, directional signs, code required signs, telephone identification signs and temporary interior signs.

B. Manufacturer shall provide software templates including graphics and layouts for changeable inserts.

C. http:www.cfm.va.gov/til/signs/Signage09-Interior.pdf

1.2 RELATED WORK

A. Electrical: Related Electrical Specification Sections.

B. Lighted EXIT signs for egress purposes are specified under Division 26, ELECTRICAL.

1.3 MANUFACTURER'S QUALIFICATIONS

A. Sign manufacturer shall provide evidence that they regularly and presently manufacturers signs comparable to those specified in this section as one of their principal products. Sign vendor shall have at least 5 years’ experience, be on GSA Schedule 078 for re-orders, and have completed 5 other similar VA signage projects within the last 5 years.

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 00, SHOP DRAWINGS, PRODUCT DATA

AND SAMPLES.

B. Manufacturer's Literature:

1. Showing the methods and procedures proposed for the concealed anchorage of the signage system to each surface type.

2. Printed specifications, anchorage details, installation and maintenance instructions.

3. GSA Schedule information showing products and components are listed

C. Samples: Sign panels and frames, with letters, symbols and graphics for each sign type. Submit 2 sets. One set of samples will be retained by

COR, other returned to Contractor.

1. Sign Panel, 200 mm x 250 mm (8 inches x 10 inches), with letters.

2. Color samples of each color, 150 mm x 150 mm (6 inches x 6 inches.

Show anticipated range of color and texture.

3. Sample of typeface, arrow and symbols in a typical full-size layout.

10 14 00 - 2

D. Shop Drawings:

1. Scaled for manufacture and fabrication of sign types. Identify materials, show joints, welds, anchorage, accessory items, mounting and finishes.

2. Sign location plan, showing location, type and total number of signs required.

E. Full size layout patterns for dimensional letters.

F. Certifications:

1. Compliance with environmental attributes listed in specification.

2. Compliance with variable dot UV printing for color and graphics

1.5 DELIVERY AND STORAGE

A. Deliver materials to job in manufacturer's original sealed containers with brand name marked thereon. Protect materials from damage.

B. Package to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary.

C. Deliver signs only when the site and mounting services are ready for installation work to proceed.

D. Store products in dry condition inside enclosed facilities.

1.6 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. American Society for Testing and Materials (ASTM):

B209-07.................Aluminum and Aluminum-Alloy Sheet and Plate

B221-08.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and tubes.

C. Federal Specifications (Fed Spec):

MIL-PRF-8184F...........Plastic Sheet, Acrylic, Modified.

MIL-P-46144C............Plastic Sheet, Polycarbonate

1.7 MINIMUM SIGN REQUIREMENTS

A. Permanent Rooms and Spaces:

1. Tactile and Braille Characters, raised minimum 0.793 mm (1/32 in).

Characters shall be accompanied by Grade 2 Braille.

2. Type Styles: As indicated on Drawings.

3. Character Height: Minimum 16 mm (5/8 in) high, Maximum 50 mm (2 in).

10 14 00 - 3

4. Symbols (Pictograms): Equivalent written description shall be placed directly below symbol, outside of symbol's background field. Border dimensions of symbol background shall be minimum 150 mm (6 in) high.

5. Finish and Contrast: Characters and background shall be eggshell, matte or other non-glare finish with adequate contrast with background.

6. Mounting Location and Height: As shown. Mounted on wall adjacent to the latch side of the door and to avoid door swing and protruding objects.

7. Aluminum frame is clear anodized with a minimum of 75% recycled aluminum content.

8. All wall mounted signs must be mechanically fastened to the wall with concealed screws and plugs.

9. Acrylic sign components holding inserts must be magnetically mounted allowing sign messages to be easily slid out and changed.

10. Insert software program with unlimited license that auto scales the copy to fit each sign approximately allowing signs to be updated in house on any standard computer and printer must be provided.

11. Background color, non-tactile copy and graphics shall be subsurface digitally printed direct to substrate with variable dot pattern, UV ink containing NO VOCs and LED curing. Painting and screen printing

B. Overhead Signs:

1. Type Styles: As shown. Characters shall have a width-to-height ratio between 3:5 and 1:1. Characters shall have a stroke width-to-height ratio of between 1:5 and 1:10.

2. Character Height: minimum 75 mm (3 in) high for overhead signs. As shown, for directional signs.

3. Finish and Contrast: Same as for signs of permanent rooms and spaces.

4. Mounting Location and Height: As shown.

5. Background color, non-tactile copy and graphics shall be subsurface digitally printed direct to substrate with variable dot pattern, UV ink containing NO VOCs and LED curing. Painting and screen printing shall not be used.

10 14 00 - 4

1.8 COLORS AND FINISHES:

A. Room, Patient Bed and Room Signs, and Restroom Signs

1. Frame: Extruded metal Natural Satin

2. 3”x7” Top Insert Band: ADA insert band: Photopolymer Color: A03 Warm

Grey with 70% contrast minimum with text

3. 3”x7” Top “Bed” Insert: Photopolymer Color: A03 Warm Grey; Vinyl copy: surface applied, Color: A01 White Matte

4. Lower Display Window Sign Background: 150 Silver

5. Lower Display Window Custom Digital Graphic Image Insert: To be selected by VA.

6. Lower Display Window Text: Color to be selected by VA.

B. Fire Equipment Identification Sign Components

1. Acrylic plaque background color: Red

2. Graphic Silk-screened Text and Symbol: White

C. Directory Sign: Refer to Drawings

PART 2 - PRODUCTS

2.1 GENERAL

A. Basis of Design: Signage as supplied by Creative Signage System, Inc.

11469-B Edmonston Road, Beltsville, MD 20705; Phone: 301-345-3700;

Email: creative@creativesignage.com.

1. All products must be readily available and non-proprietary items on

GSA Schedule 078 for ease in future procurement. All signs to be

American made covered under standard GSA warranties.

B. Graphic inserts shall be provided as specified; be of a durable, washable material; and be easily changed out by the nursing staff as needed without additional tools.

C. The sign backer panel color must meet the contrast requirements with the sign text that is called for by ABA/ADA.

D. All product components shall be available on GSA schedules.

E. Finishes and styles shall be modular with components that are interchangeable with existing Beckley WV, VA Medical Center’s signage.

F. Signs of type, size and design shown on the drawings and as specified.

G. Signs shall be provided complete with lettering, framing and related components for a complete installation.

10 14 00 - 5

H. Display Window Custom Digital Graphic Image Insert: Provide artwork for custom image as specified. Custom graphic image insert shall be provided on laminated Card Stock. Graphic image to be selected by VA from Getty Images or from the manufacturer’s standard images with no less than 25 nature scene images with the option for alternate colors for any individual image.

I. Provide graphics items as completed units produced by a single manufacturer, including necessary mounting accessories, fittings and fastenings.

J. Do not scale drawings for dimensions. Contractor to verify and be responsible for all dimensions and conditions shown by these drawings.

COR to be notified of any discrepancy in drawing, in field directions or conditions, and/or of any changes required for all such construction details.

K. The Sign Contractor, by commencing work of this section, assumes overall responsibility, as part of his warranty of work, to assure that assemblies, components and parts shown or required within the work of the section, comply with the Contract Documents. The Contractor shall further warrant: That all components, specified or required to satisfactorily complete the installation are compatible with each other and with conditions of installations.

2.2 PRODUCTS

A. Aluminum:

1. Sheet and Plate: ASTM B209.

2. Extrusions and Tubing: ASTM B221.

B. Cast Acrylic Sheet: MIL-PRF-8184F; Type II, class 1, Water white 2-ply non-glare optically clear.

1. Matt finish water white clear acrylic shall not be acceptable.

C. Polycarbonate: MIL-P-46144C; Type I, class 1.

D. Vinyl: 0.1 mm thick machine cut, having a pressure sensitive adhesive and integral colors.

E. Wood: Solid wood header for suspended overhead signs to match wood finish as specified in Finish Legend on Drawings.

2.3 SIGN STANDARDS

A. Typography:

1. Type Style: Helvetica Medium and Helvetica Medium Condensed. Initial caps or all caps as indicated in Sign Message Schedule.

10 14 00 - 6

2. Arrow: See graphic standards in drawings.

3. Letter spacing: See graphic standards on drawings.

4. Letter spacing: See graphic standards on drawings.

5. All text, arrows, and symbols to be provided in size, colors, typefaces and letter spacing shown. Text shall be a true, clean, accurate reproduction of typeface(s) shown. Text shown in drawings are for layout purposes only; final text for signs is listed in Sign

Message Schedule.

B. Project Colors and Finishes: Provide as specified or selected by COR.

C. Sign Features:

1. Concealed locking mechanism for security User-updatable inserts

Modular System with interchangeable Compatible with existing modular systems ADA compliant Custom message bands

2. Decorative finishes and custom graphics compatible with digitally printed or silk-screened graphics

3. Low-profile graphics display system

4. Tamper-resistant, modular, economical, and attractive

5. Variety of sizes available.

6. Custom Digital Image System shall be provided in an electronic format for VA’s use to update signage inserts.

7. The new styles of component sign systems should provide for the ability to update inserts that are printed on digital printers, allowing for immediate message replacements that can be created at the facility, rather than having to be ordered from a sign manufacturer. This approach applies to room signs as well as directional signs.

2.4 SIGN TYPES

A. General:

1. The interior sign system is comprised of sign type families that are identified by a letter and number which identify a particular group of signs. An additional number identifies a specific type of sign within that family. Signage shall be as noted in the drawings and specifications and illustrated in the VA Signage Design Guide located at http://www.cfm.va.gov/til/spclRqmts.asp#SIGN.

a. IN indicates an Interior component, construction-based sign.

10 14 00 - 7

B. Interchangeable Component Signage Systems:

1. Sign Type Families: 01, 04, 05, 07 and 09.

2. Interior sign system capable of being arranged in a variety of configurations with a minimum of attachments, devices and connectors.

a. Interchangeable nature of the system shall allow for changes of graphic components of the installed sign, without changing sign in its entirety.

b. Component Sign System is comprised of the following primary components:

1) Rail Back utilizing horizontal rails, spaced to allow for uniform, modular sizing of sign types.

2) Rail Insert mounted to back of Copy Panels to allow for attachment to Rail Back.

3) Copy Panels, made of a variety of materials to allow for different graphic needs.

4) End Caps which interlock to Rail Back to enclose and secure changeable Copy Panels.

5) Joiners and Accent Joiners connect separate Rail Backs.

6) Top Accent Bars which provide decorative trim cap that encloses the top of sign or can connect the sign to a Type 03

Room Number Sign.

c. Rail Back, Rail Insert and End Caps in anodized extruded aluminum to allow for tight tolerances and consistent quality of fit and finish.

d. Signs in system shall be convertible in the field to allow for enlargement from one size to another in height and width through use of Joiners or Accent Joiners, which connect Rail Back panels together blindly, providing a butt joint between Copy Panels.

Accent Joiners shall connect Rail Backs together with a visible 3 mm (1/8") horizontal rib, flush to the adjacent copy insert surfaces.

e. Sign configurations shall vary in width from 225 mm (9 inches) to

2050 mm (80 inches) and have height dimensions of 50 mm (2 inches), 75 mm (3 inches), 150 mm (6 inches), 225 mm (9 inches) and 300 mm (12 inches). Height shall be increased beyond 300 mm

(12 inches), by repeating height module in full or in part.

10 14 00 - 8

3. Rail Back functions as internal structural member of sign using

6063T5 extruded aluminum and anodized black.

a. Shall accept an extruded aluminum or plastic insert on one sign or on both sides, depending upon sign type.

b. Shall be convertible in field to allow for connection to other

Rail Back panels, so that additive changes can be made to sign unit.

c. Rail shall allow for a variety of mounting devices including wall mounting for screw-on applications, using pressure sensitive tape, freestanding mount, ceiling mount and other mounting devices as needed.

4. Rail Insert functions as a mounting device for Copy Panels on to the

Rail Back. The Rail Insert mounts to the back of the Copy Panel with adhesive suitable for use with the copy insert material.

a. Shall allow Copy Panels to slide or snap into the horizontal Rail

Back for ease of changeability.

b. Shall mount to the back of the Copy Panel with adhesive suitable for use with Copy Panel material.

5. Copy Panels shall accept various forms of copy and graphics and attaches to the Rail Back with the Rail Insert. Copy Panels shall be either ABS plastic with integral color or an acrylic lacquer finish;

photo polymer; or acrylic.

a. Interchangeable by sliding horizontally from either side of sign, and to other signs in system of equal or greater width or height.

b. Cleanable without use of special chemicals or cleaning solutions.

c. Copy Insert Materials.

1) ABS Inserts - 2.3 mm (.090 inches) extruded ABS plastic core with .07 mm (.003 inches) acrylic cap bonded during extrusion/texturing process. Pressure bonded to extruded Rail

Insert using adhesive. Background color is either integral or painted in acrylic lacquer. ABS inserts finished in a chromium industries #HM335RA texture pattern to prevent glare.

2) Photo polymer Inserts - 3 mm (.125 inches) phenolic photo polymer with raised copy etched to 2.3 mm (.0937 inches), bonded to an ABS plastic or extruded aluminum insert with adhesive. Background color is painted in acrylic enamel.

10 14 00 - 9

3) Changeable Display Window Custom Digital Graphic Image Insert:

Laminated Paper with Graphic and Insert Holder.

a) Insert Holder: Extruded insert holder with integral Rail

Insert for connection with structural back panel in

6063T5 aluminum with a black anodized finish. Holder shall be a one-piece sign background color in aluminum or silver painted in acrylic lacquer.

b) Custom Digital Graphic Image inserts into holder are laminated paper with digital graphic as selected by VA,

c) Acrylic Non-Glare Lens Cover: a clear 0.7 mm (.030 inches) textured cover.

4) Acrylic - 2 mm (.080 inches) non-glare acrylic. Pressure bonded to extruded Rail Insert using adhesive. Background color is painted in acrylic lacquer or acrylic enamel.

5) Extruded 6063T5 aluminum with a black anodized finish Insert

Holder with integral Rail Insert for connection with

Structural Back Panel to hold a 0.7 mm (.030 inches) textured polycarbonate insert and a Sliding Tile which mounts in the

Inset Holder and slides horizontally.

6) End Caps - Extruded using 6063T5 aluminum with a natural satin finish. End Caps interlock with Rail Back with clips to form an integral unit, enclosing and securing the changeable Copy

Panels, without requiring tools for assembly.

a) Shall be interchangeable to either end of sign and to other signs in the system of equal height.

b) Mechanical fasteners can be added to the End Caps that will secure it to Rail Back to make sign tamper resistant. These fasteners shall not impede the ability for quick interchangeability of inserts and graphics.

7) Joiners - Extruded using 6063T5 aluminum with a black anodized finish. Rail Joiners connect Rail Backs together blindly, providing a butt joint between Copy Inserts.

8) Accent Joiners - Extruded using 6063T5 aluminum with a natural satin finish. Joiner shall connect Rail Backs together with a visible 3 mm (.125 inches) horizontal rib, flush to the adjacent Copy Panel surfaces.

10 14 00 - 10

9) Top Accent Rail - Extruded using 6063T5 aluminum with a natural satin finish. Rail shall provide 3 mm (.125 inches) high decorative trim cap, which butts flush to adjacent Copy

Panel and encloses top of Rail Back and Copy Panel.

10) Typography

a) Vinyl First Surface Copy (non-tactile) - Applied Vinyl copy.

b) Subsurface Copy Inserts - Textured 1 mm (.030 inches) clear polycarbonate face with subsurface applied Vinyl copy. Face shall be back sprayed with paint and laminated to an extruded aluminum carrier insert.

c) Integral Tactile Copy Inserts - phenolic photo polymer etched with 2.3 mm (.0937 inches) raised copy.

d) Silk-screened First Surface Copy (non-tactile) - Injection molded or extruded ABS plastic or aluminum insert with first surface applied enamel silk-screened copy.

C. Sign Type Family 01: Fire Equipment Identification Sign

10 14 00 - 11

1) Installation: Centered above fire equipment cabinet a 2129 mm

(7'-0") to bottom of sign; mechanically fastened to wall with expandable anchors as needed for wall type.

D. Sign Type Family 04: Room Identification Sign with insert.

1. Tactile sign is to be made from a material that provides for letters, numbers and Braille to be integral with sign plaque material such as: photosensitive polyamide resin, etched metal, sandblasted phenolic or embossed material. Do not apply letters, numbers and Braille with adhesive.

2. Numbers, letters and Braille to be raised 0.793 mm (.0312 inches) from the background surface. The draft of the letters, numbers and

Braille to be tapered, vertical and clean.

3. Braille dots are to conform with standard dimensions for literary

Braille; (a) Dot base diameter: 1.5 mm (.059 inches) (b) Inter-dot spacing: 2.3 mm (.090 inches) (c) Horizontal separation between cells: 6.0 mm (.241 inches) (d) Vertical separation between cells:

10.0 mm (.395 inches)

4. Entire assembly is painted in specified color. After painting, apply white or other specified color to surface of the numbers and letters. Entire sign is to have a protective clear coat sealant applied.

5. Complete sign is to have an eggshell finish (11 to 19 degree on a

60-degree glossmeter).

6. Inserts:

a. Lower Section Display Window and Custom Digital Graphic Image

Insert:

1) Display Window Background finish: 150 Silver.

2) Custom digital Graphic image insert shall be provided on laminated two sides on Card Stock. Graphic image to be

10 14 00 - 12 selected by VA from Getty Images or from the manufacturer’s standard images with no less than 25 nature scene images with the option for alternate colors for any individual image.

3) Text Copy shall be vinyl cut letters reverse applied to the non-glare acrylic lens: “Please check in with nurse’s station before entering patient room.”.

b. Top section is joined to the lower window section with connecting

Accent Joiner used to create a singular integrated sign.

c. Signs identifying electrical closets, mechanical rooms and telecommunication rooms should consist of only the room number.

d. Representative illustration (Digital Graphic Image Insert not shown but required)

e. Where sign is mounted on glass, provide a 9” x 9” .050” steel plate (finish: 101 Satin Natural) on the opposite side of the glass (directly opposite the sign. Secure the sign and plate to the glass with silicone sealant.

10 14 00 - 13

f. Installation location.

E. Sign Type 05: Patient Room Identification Sign.

1. IN-05.07 Patient Room Identification with Patient Condition Pull

Outs on side (left or right-handed - Pull-Outs shall be located on the side as directed by COR.

a. Basis of Design: INFO2FV-E-6R, APCO - InfoLock Sign assembly with Economy FullView sign. Sign includes (6) InfoLock bands

2.5” single sided pull-out orientation. FullView holder with

3” ADA plaque and an 11.375” x 7.13” display area, ADO insert.

(Graphic and/or Text as directed by COR).

10 14 00 - 14

Representative image but room number sign shall be at the top location and window insert below. Digital Graphic Image Insert not shown but required.

1) 3” Top Section with Primary tactile braille panel layout

2) Lower Section Window Insert:

a) Background finish: 150 Silver.

b) Custom graphic image insert shall be provided on laminated Card Stock. Graphic image to be selected by VA from Getty Images or from the manufacturer’s standard images with no less than 25 nature scene images with the option for alternate colors for any individual image.

c) Text Copy shall be vinyl cut letters reverse applied to the non-glare acrylic lens: “Please check in with nurse’s station before entering patient room,”

3) Graphic Pull Out insert images as per Syracuse VAMC standards:

Graphic Pull Out inserts shall be interchangeable. Tabs shall be natural satin finish.

10 14 00 - 15

4) Where sign is mounted on glass, provide a 1’-1” x 11 – ¾”

.050” steel plate (finish: 101 Satin Natural) on the opposite side of the glass (directly opposite the sign. Secure the sign and plate to the glass with silicone sealant.

5) Installation locations

F. Sign Type 07: Room Sign with Indicator

1. Sign shall have tactile raised text and Braille.

2. Sign shall list the room number above the room name.

3. Sign shall have a sliding rail at the bottom to indicate whether room is occupied or unoccupied.

10 14 00 - 16

G. Sign Type 09: Restroom Identification

1. Signs shall have symbol, tactile raised text and Braille.

10 14 00 - 17

a. Graphic layout and Installation location:

H. Temporary Interior Signs:

1. Fabricated from 50 kg (110 pound) matte finished white paper cut to

100 mm (4 inch) wide by 300 mm (12 inch) long. Punched 3 mm (.125 inch) hole with edge of hole spaced 13 mm (.5 inch) in from edge and centered on 100 mm (4 inch) side. Reinforce hole on both sides with suitable material that prevents tie form pulling through hole. Ties are steel wire 0.3 mm (0.120 inch) thick attached to tag with twist leaving 150 mm (6 inch) long free ends.

2. Mark architectural room number on sign, with broad felt marker in clearly legible numbers or letters that identify room, corridor or space as shown on floor plans.

10 14 00 - 18

3. Install temporary signs to all rooms that have a room, corridor or space number. Attach to door frame, doorknob or door pull.

a. Doors that do not require signs include the following: corridor doors in corridor with same number, folding doors or partitions, toilet doors, bathroom doors within and between rooms, closet doors within rooms, communicating doors in partitions between rooms with corridor entrance doors.

b. Replace and missing damaged or illegible signs.

2.5 FABRICATION

A. Design components to allow for expansion and contraction for a minimum material temperature range of 56 °C (100 °F), without causing buckling, excessive opening of joints or over stressing of adhesives, welds and fasteners.

B. Form work to required shapes and sizes, with true curve lines and angles. Provide necessary rebates, lugs and brackets for assembly of units. Use concealed fasteners whenever and wherever possible.

C. Shop fabricate so far as practicable. Joints fastened flush to conceal reinforcement or welded where thickness or section permits.

D. Contact surfaces of connected members be true. Assembled so joints will be tight and practically unnoticeable, without use of filling compound.

E. Signs shall have fine, even texture and be flat and sound. Lines and miters sharp, arises unbroken, profiles accurate and ornament true to pattern. Plane surfaces be smooth flat and without oil-canning, free of rack and twist. Maximum variation from plane of surface plus or minus

0.3 mm (0.015 inches). Restore texture to filed or cut areas.

F. Level or straighten wrought work. Members shall have sharp lines and angles and smooth su1rfaces.

G. Extruded members to be free from extrusion marks. Square turns and corners sharp, curves true.

H. Drill holes for bolts and screws. Conceal fastenings where possible.

Exposed ends and edges mill smooth, with corners slightly rounded. Form joints exposed to weather to exclude water.

I. Finish hollow signs with matching material on all faces, tops, bottoms and ends. Edge joints tightly mitered to give appearance of solid material.

10 14 00 - 19

J. All painted surfaces properly primed. Finish coating of paint to have complete coverage with no light or thin applications allowing substrate or primer to show. Finished surface smooth, free of scratches, gouges, drips, bubbles, thickness variations, foreign matter and other imperfections.

K. Movable parts, including hardware, are be cleaned and adjusted to operate as designed without binding of deformation of members. Doors and covers centered in opening or frame. All contact surfaces fit tight and even without forcing or warping components.

L. Pre-assemble items in shop to greatest extent possible to minimize field splicing and assembly. Disassemble units only as necessary for shipping and handling limitations. Clearly mark units for re-assembly and coordinated installation.

M. No signs are to be manufactured until final sign message schedule and location review has been completed by the COR & forwarded to contractor.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Protect products against damage during field handling and installation.

Protect adjacent existing and newly placed construction, landscaping and finishes as necessary to prevent damage during installation. Paint and touch up any exposed fasteners and connecting hardware to match color and finish of surrounding surface.

B. Mount signs in proper alignment, level and plumb according to the sign location plan and the dimensions given on elevation and sign location drawings. Where otherwise not dimensioned, signs shall be installed where best suited to provide a consistent appearance throughout the project. When exact position, angle, height or location is in doubt, contact COR for clarification.

C. Contractor shall be responsible for all signs that are damaged, lost or stolen while materials are on the job site and up until the completion and final acceptance of the job.

D. Remove or correct signs or installation work COR determines as unsafe or as an unsafe condition.

E. At completion of sign installation, clean exposed sign surfaces. Clean and repair any adjoining surfaces and landscaping that became soiled or damaged as a result of installation of signs.

10 14 00 - 20

F. Locate signs as shown on the Sign Location Plans.

G. Certain signs may be installed on glass. A blank glass back up is required to be placed on opposite side of glass exactly behind sign being installed. This blank glass back up is to be the same size as sign being installed.

H. Contractor will be responsible for verifying that behind each sign location there are no utility lines that will be affected by installation of signs. Any damage during installation of signs to utilities will be the sole responsibility of the Contractor to correct and repair.

I. Furnish inserts and anchoring devices which must be set in concrete or other material for installation of signs. Provide setting drawings, templates, instructions and directions for installation of anchorage devices which may involve other trades.

- - - END - - -

10 21 23 - 1

SECTION 10 21 23

CUBICLE CURTAIN TRACKS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies shower curtain tracks and shower curtains.

1.2 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Samples:

1. 305 mm (12 inch) long piece of shower curtain track assembly.

2. One shower curtain and associated carriers.

C. Shop Drawings: Showing layout of tracks and method of anchorage.

D. Manufacturer's Literature and Data:

1. Shower curtain track.

2. Shower curtain and curtain carriers.

1.3 DELIVERY, STORAGE AND HANDLING

A. Deliver material in original package marked to identify the contents, brand name, and the name of the manufacturer or supplier.

B. Store in dry and protected location so tracks do not bend or warp.

C. Do not open packages until contents are needed for installation, unless verification inspection is required.

1.4 WARRANTY

A. Construction Warranty: Cubicle curtain tracks are subject to the terms of the Article “Warranty of Construction,” FAR clause 52.246-21.

1.5 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. ASTM International (ASTM):

B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)

B456-17.................Electrodeposited Coatings for Copper Plus

Nickel Plus Chromium and Nickel Plus Chromium

10 21 23 - 2

C. Aluminum Association (AA):

DAF 45-09...............Designation System for Aluminum Finishes

D. American Architectural Manufacturers Association (AAMA):

2603-20.................Voluntary Specification, Performance

Requirements and Test Procedures for Pigmented

Organic Coatings on Aluminum Extrusions and

Panels (with Coil Coating Appendix)

E. American Association of Textile Chemists and Colorists (AATCC):

AATCC-22................Water Repellency, Spray Test

AATCC-118.............. Oil Repellency, Hydrocarbon Resistance Test

AATCC-193 ............. Aqueous Liquid Repellency, Water/Alcohol

Solution Resistance Test

F. California Administrative Code Title 19, Public Safety (CAL19):

Section 1237............Flame Resistance, Small Scale Test

G. The National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500-06 Series.......Metal Finishes Manual

H. The National Fire Prevention Association (NFPA):

NFPA 701................Standard Methods of Fire Tests for Flame

Propagation of Textiles and Films.

PART 2 - PRODUCTS

2.1 SHOWER CURTAIN TRACK

A. Basis of Design: Imperial Fastener Co. – IFC-69 Track.

B. Provide corrosion resistant extruded, aluminum surface mounted ceiling track system for curtain support

C. Provide glider hooks at 10 per meter (3.28 feet). Length as necessary to suspend curtain below patient lift track as indicated on Drawings.

2.2 CURTAINS:

A. Basis of Design: InPro, Clickeze Super Bio Stat, antimcrobial shower curtain fabric.

B. Fabric to be non-woven, 100 percent polyester, modified with flame retardant, anti-bacterial, stain resistant, mold resistant and water repellant additives.

C. Curtain Height: Size curtains to maintain bottom 51 mm (2 inches) above floor level. Coordinate actual length with ceiling height and required head clearance at patient lift system cross over locations as verified in field prior to shop drawing submittal.

10 21 23 - 3

D. Curtain Length: Provide single piece curtains full length of track plus

10 percent; minimum extra length of 305 mm (12 inches).

E. Fabric Color: As selected by Architect.

2.3 FASTENERS

A. Exposed Fasteners, Screws and Bolts: Stainless steel or chromium/nickel plated brass.

B. Concealed Fasteners, Screws and Bolts: Stainless steel.

C. Metal Clips: Anchor curtain tracks to exposed grid of lay-in acoustical tile ceilings, with concealed metal (butterfly) type or two piece snap locking type ceiling clip of high strength spring steel.