36C24520Q0392-016.pdf
PDF Posted
- Solicitation number
- 36C24520Q0392
About this file
This package includes construction drawings and specifications for renovations to a Veterans Affairs residential treatment facility. The drawings show demolition plans, site plans, plumbing diagrams, and other details for the project scope. Specifications cover requirements for housekeeping services at the facility located in Huntington, West Virginia.
The solicitation is for housekeeping services at the Hershel Woody Williams VA Medical Center, with a response due date of May 29, 2020. The small business set-aside procurement is open to Service-Disabled Veteran Owned Small Businesses under NAICS code 561720 with a size standard of $19.5 million. Interested contractors must be registered in the Vendor Information Pages database and SAM.gov to be eligible for award. The solicitation documents were issued on May 5, 2020 and inquiries are to be directed via email only to the point of contact listed.
36C24520Q0392 Drawings 1 RRTP.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24520Q0392 0001.pdf | ||
| 36C24520Q0392.pdf | ||
| 36C24520Q0392-017.pdf | ||
| 36C24520Q0392-015.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING SYMBOL LEGEND
X
DRAWING BLOCK TITLES:
EXTERIOR ELEVATION
INDICATOR:
INTERIOR ELEVATION
INDICATOR FOR
MULTIPLE VIEWS:
CONTRACTOR NOTE
D E P A R T M E N T O F
V E T E R A N S A F F A I R S
G101
PROJECT LOCATION
G102
BATH
BATH
TWO BEDROOM
TWO BEDROOM
BATH
BATH
TWO BEDROOM
BATH
ELEC. ROOM
LAUNDRY
LOUNGE
DINING
FAMILY
VISITATION
SEC. STOR.
LOCKED MEDS
ELEV. MACH.
ROOM
KITCHEN
NURSES STATION
SOILED
BATH
BATH
BATH
STAIR
CORR.
TOILET
LOBBY
TWO BEDROOM
TWO BEDROOM
TWO BEDROOM
STAIR
CORRIDOR
LINEN CLOSET
VESTIBULE
TWO BEDROOM
PRIVATE BEDROOM
CORRIDOR
CORR.
MANAGER
ADMIN
SUPPORT/COPY
TOILET
REF
DW
NURSES STATION
TOILET
EXAM
TREATMENT
PEER TECH/
DIETICIANSOCIAL WORKER
SOCIAL WORKER
PSYCHOLOGIST
PSYCHOLOGIST
BREAKROOM
GROUP THERAPY
GROUP THERAPY
CLEAN
STORAGE
HAC
MECH./
ELEC.
RECEPTION
STOR.
IT
COMM.
SEC.
FITNESS
TOILET
STAIR
STAIR
CORRIDOR
CORRIDOR
FITNESS OFFICE
ELEVATOR
FIRE
PROTECTION
MECHANICAL
ELEVATOR
PIT
G103
LIFE SAFETY PLAN
FIRST FLOOR LIFE SAFETY PLAN 1/8"=1'-0"
SECOND FLOOR LIFE SAFETY PLAN 1/8"=1'-0"
BASEMENT LIFE SAFETY PLAN 1/8"=1'-0"
CNSIII CNSIII
1. THE LIFE SAFETY PLAN IS BASED ON NFPA 101 - LIFE SAFETY CODE, 2015 EDITION.
2. MECHANICAL SHAFT WALLS ARE NON-RATED WALLS. FIRE DAMPERS ARE INSTALLED THE THE
1 HOUR RATED FLOOR.
3. THE LENGTH OF TRAVEL FROM ANY LOCATION, TO EITHER STAIRWELL, IS LEST THAN 50 FEET.
BENCH MARK
PIN EL. 872.45
REMOVE AND RESET BENCH
EXIST. F.O. LINE TO REMAIN
RELOCATE SHELTER
EXIST. BOLLARDS
REMOVE TREES
REMOVE TREES
REMOVE SIGNS
REMOVE TREES
TO REMAIN (TYP.)
EXIST. CONC. TO REMAIN
EXIST. LP TO REMAIN
INSTALL TREE PROTECTION
FENCE (TYP.)
INSTALL CONSTR. SAFETY
FENCE
SIGN BARRICADE
(SIDEWALK CLOSED)
SIGN BARRICADE
(SIDEWALK CLOSED)
INSTALL CONSTR. SAFETY
FENCE
EXIST. SW TO REMAIN
INSTALL CONSTRUCTION DRUMS
@ 8' C/C SPACING
REMOVE PORTION OF WALL
REMOVE EIGHT (8) PARKING
BLOCK AND REUSE
(SEE NOTE 1)
DISMANTLE AND
DEMOLITION AND
SITE PROTECTION PLAN
JCW LAS
10'20' 20'0
LEGEND
WATER LINE
PROPOSED SANITARY SEWER LINE
STEAM LINE
STORM SEWER LINE
UNDERGROUND ELECTRIC CONDUIT
EXISTING SIGN
EXISTING PROTECTIVE BOLLARD
EXISTING YARD DRAIN
EXISTING LIGHT POLE
EXISTING STORM DRAIN INLET
UNDERGROUND TELEPHONE CONDUIT
*880.70 APPROX. ELEV.; MATCH EXISTING
SEWER CLEAN OUT
MANHOLE
PROPOSED WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING SANITARY MANHOLE
EXISTING STORM MANHOLE
NOTES:
1. CONTRACTOR SHALL DISMANTLE AND RELOCATE
SHELTER AS DIRECTED.
2. USE TRVPT #5 FOR SITE BENCHMARK. LOCATED SOUTH
OF BUILDING 5. (ELEVATION = 881.79)
NEW ASPHALT PARKING
(7 ADD. SPACES)
L
S
L
S
L
S
L
S
F
F
N
E
W
B
U
I
L
D
I
N
G
SITE PLAN
JCW LAS
10'20' 20'0
LEGEND
WATER LINE
PROPOSED SANITARY SEWER LINE
STEAM LINE
STORM SEWER LINE
UNDERGROUND ELECTRIC CONDUIT
EXISTING SIGN
EXISTING PROTECTIVE BOLLARD
EXISTING YARD DRAIN
EXISTING LIGHT POLE
EXISTING STORM DRAIN INLET
UNDERGROUND TELEPHONE CONDUIT
*880.70 APPROX. ELEV.; MATCH EXISTING
SEWER CLEAN OUT
MANHOLE
PROPOSED WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING SANITARY MANHOLE
LANDSCAPING AREA
EXISTING STORM MANHOLE
NOTES:
1. CONTRACTOR SHALL CONSTRUCT RELOCATED
SHELTER AS DIRECTED. EXACT LOCATION TO BE
DETERMINED BY VA. REINSTALLATION OF SHELTER
PAD, AND FOUNDATION SHALL MEET OR EXCEED
EXISTING. PROVIDE SHOP DRAWING TO VA FOR
APPROVAL PRIOR TO NEW WORK.
(SEE NOTE 1)
C.O.
PROPOSED WATER LINE
TIE TO EXIST. WATER LINE
NEW ASPHALT PARKING
(7 ADD. SPACES)
Y.D.
INV. 870.30
TOP 881.50
INV. 879.50
Y.D.
Y.D.
TOP 881.50
INV. 878.50
Y.D.
TOP 881.50
INV. 878.00
Y.D.
TOP 882.17
INV. 877.67
L
S
L
S
L
S
TIE TO EXIST.
STORM MANHOLE
TIE TO EXIST.
S.S. MANHOLE
INV. 868.00
INTERSECTION
EX. STORM INV. 866.27
PROP. S.S. INV. 868.56
INV. 871.50
INTERSECTION
PROP. STORM INV. 872.36
PROP. S.S. INV. 869.14
L
S
P
V
C
I
R
E
D
O
M
INSTALL FIRE HYDRANT
*882.73
*882.87
*883.25
*883.34
*883.40
*883.49
*883.54
883.50
883.17
883.50
883.50
883.50
883.50
*882.19
*880.70
*879.65
882.00
883.00
882.64
882.55
882.93
883.35
883.40
882.50
878.50
878.00
874.33
874.33
*883.15
*883.15
*883.08
F
N
I
L
D
I
N
G
TOP 881.50
INV. 879.00
C
P
V
C
3~6" GATE VALVES
Y.D.
TOP 873.00
INV. 871.00
Y.D.
TOP 873.90
INV. 869.90
C
C
C
C
C
C
C
PROPOSED FIRE LINE
INV. 869.70
INSTALL 6" GATE VALVE
I
R
E
C
F
I
R
E
DS
DS
DS
DS
DS
DS
882.50
882.50
SITE GRADING PLAN
JCW LAS
10'20' 20'0
LEGEND
WATER LINE
PROPOSED SANITARY SEWER LINE
STEAM LINE
STORM SEWER LINE
UNDERGROUND ELECTRIC CONDUIT
EXISTING SIGN
EXISTING PROTECTIVE BOLLARD
EXISTING YARD DRAIN
EXISTING LIGHT POLE
EXISTING STORM DRAIN INLET
UNDERGROUND TELEPHONE CONDUIT
*880.70 APPROX. ELEV.; MATCH EXISTING
SEWER CLEAN OUT
MANHOLE
PROPOSED WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING SANITARY MANHOLE
LANDSCAPING AREA
EXISTING STORM MANHOLE
DOWNSPOUT
NOTES:
1. INSTALL PRE-CAST CONCRETE SPLASH BLOCKS ON
SOUTHEAST SIDE OF BUILDING DOWNSPOUTS.
2. INSTALL PVC DOWNSPOUT TO 5" PVC ADAPTER WITH 6"
PVC PIPE TO DRAINAGE SYSTEM ON NORTHWEST SIDE OF
BUILDING.
3. USE 5' MIN. RADII AT ALL SIDEWALK INTERSECTIONS AS
SHOWN ON PLAN.
I
R
E
D
O
M
F
N
I
L
D
I
N
G
INSTALL SILT FENCE
INSTALL DANDY SACK
INLET PROTECTION
INSTALL STD. INLET
PROTECTION (TYP.)
TEMPORARY CONSTRUCTION
ENTRANCE
C
P
V
C
C
C
C
C
C
C
C
I
R
E
C
F
I
R
E
DS
DS
DS
DS
DS
DS
INSTALL STD. INLET
PROTECTION (TYP.)
EROSION AND SEDIMENT
JCW LAS
10'20' 20'0
CONTROL PLAN
LEGEND
WATER LINE
PROPOSED SANITARY SEWER LINE
STEAM LINE
STORM SEWER LINE
UNDERGROUND ELECTRIC CONDUIT
EXISTING SIGN
EXISTING PROTECTIVE BOLLARD
EXISTING YARD DRAIN
EXISTING LIGHT POLE
EXISTING STORM DRAIN INLET
UNDERGROUND TELEPHONE CONDUIT
*880.70 APPROX. ELEV.; MATCH EXISTING
SEWER CLEAN OUT
MANHOLE
PROPOSED WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING SANITARY MANHOLE
N
I
L
D
I
N
G
Id(1)
Bg(10)
Bg(3)
Bg(4)
Bg(2)
Bg(2)
Bg(5)
Bg(3)
Bg(3)
Ig(1)
Ig(1)
Pt(1)
Cf(1)
LANDSCAPING PLAN
LEGEND
WATER LINE
PROPOSED SANITARY SEWER LINE
STEAM LINE
STORM SEWER LINE
UNDERGROUND ELECTRIC CONDUIT
EXISTING SIGN
EXISTING PROTECTIVE BOLLARD
EXISTING YARD DRAIN
EXISTING LIGHT POLE
EXISTING STORM DRAIN INLET
UNDERGROUND TELEPHONE CONDUIT
*880.70 APPROX. ELEV.; MATCH EXISTING
SEWER CLEAN OUT
MANHOLE
JCW LAS
5'10' 10'0
NOTE: SEE LANDSCAPING DETAILS FOR
PLANT DESCRIPTIONS, SIZES AND
ADDITIONAL INFORMATION.
PROPOSED WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING SANITARY MANHOLE
TO POST
SILT FENCE
MIN.
MIN.
MIN.
MIN.
FLOW
F
L
O
W
BACKFILL
IN TRENCH
24"
10'
MAX.
SILT FABRIC
STAPLED TO
COMPACTED
TRENCH
6" x 6"
POSTS
18"
42"
24"
FABRIC
ANCHORED
POST (2" X 2"
SILT FENCE FABRIC
ANCHORED IN TRENCH
AND FIRMLY ATTACHED
6" x 6"
TRENCH
SILT FENCE
DETAIL
NOT TO SCALE
CONTROL GENERAL NOTES:
DO NOT SCALE DRAWING. FOLLOW DIMENSIONS.
2.
3.
4.
5.
ADDITIONAL SILT FENCE MAY BE REQUIRED AS DIRECTED.
SILTATION CONTROL DEVICES TO REMAIN IN PLACE UNTIL
PERMIT HAS BEEN TERMINATED.
SILTATION FENCES SHALL BE INSPECTED WEEKLY FOR
DAMAGE AND FOR AMOUNT OF SEDIMENTATION WHICH HAS
ACCUMULATED. REMOVAL OF SEDIMENT WILL BE REQUIRED
ATTACHMENT OF GEOTEXTILE FABRIC TO BE IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. SILT FENCE SHALL BE
1.
WHEN IT REACHES 1/4 OF THE HEIGHT OF THE SILTATION FENCE.
EROSION & SEDIMENT
6.
CONTRACTOR SHALL DOCUMENT & RECORD ALL INSPECTION
AND MAINTENANCE ACTIVITIES SUCH AS CLEANING SEDIMENT
BASINS OR TRAPS AND OTHER SEDIMENT TRAPPING STRUCTURES
OR CATCH BASINS AS WELL AS ALL RE-SEEDING & MULCHING.
7.
CONTRACTOR SHALL DEVELOP IN ACCORDANCE WITH THESE
PLANS A DETAILED PLAN AND SCHEDULE FOR MAINTENANCE OF
ALL PERMANENT AND TEMPORARY SEDIMENT CONTROL STRUCTURES.
THIS PLAN SHALL INCLUDE A DESCRIPTION OF PROCEDURES TO
MAINTAIN IN GOOD AND EFFECTIVE CONDITION AND PROMPTLY
REPAIR OR RESTORE ALL GRADE SURFACES, WALLS, DAMS AND
STRUCTURES, VEGETATION, EROSION AND SEDIMENT CONTROL
MEASURES AND OTHER PROTECTIVE DEVICES. AT A MINIMUM,
PROCEDURES IN THE PLAN SHALL PROVIDE THAT ALL EROSION
CONTROLS ON THE SITE BE INSPECTED AT LEAST ONCE EVERY
SEVEN (7) CALENDAR DAYS AND WITHIN 24 HOURS AFTER ANY
STORM EVENT OF GREATER THAN 0.5 INCHES OF RAIN PER 24 HOURS.
9.
AS CONSTRUCTION ACTIVITIES PROGRESS IT WILL BE THE
CONTRACTOR'S RESPONSIBILITY TO ADJUST THE EROSION
& SEDIMENT PLAN ACCORDINGLY.
10.
ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED
IMMEDIATELY UPON REACHING FINAL GRADE. IN THE EVENT
THE CONSTRUCTION ACTIVITY STOPS FOR (1) ONE WEEK OR
MORE IN AN AREA, THAT AREA SHALL BE IMMEDIATELY SEEDED
AND MULCHED WITH A TEMPORARY VEGETATIVE COVER.
8.
CONTRACTOR SHALL BE RESPONSIBLE FOR TRAINING EMPLOYEES
IN PROPER USE OF SEDIMENT AND EROSION CONTROL DEVICES.
INSTALLED PERPENDICULAR TO FLOW.
NOMINAL)
DROP INLET PROTECTION
DETAIL
NOT TO SCALE
70' Min.
10'
E X
I S
T I N
G
P
A V
E M
E N
T
EXISTING GROUND
70' MIN.
MOUNTABLE BERM
(OPTIONAL)
EXISTING PAVEMENT
FILTER FABRIC
6"
PLAN
PROFILE
EXISTING GROUND
NOTES:
1. STONE SIZE - USE 2" MIN. STONE SIZE OR CRUSHED CONCRETE EQUIVALENT.
2. LENGTH - AS REQUIRED, BUT NOT LESS THAN 50'.
3. THICKNESS - NOT LESS THAN SIX (6) INCHES.
4. WIDTH - TWENTY (20') FEET MINIMUM, BUT NOT LESS THAN THE FULL WIDTH OF
PROPOSED ENTRANCE.
5. FILTER FABRIC SHALL BE PLACED OVER ENTIRE AREA PRIOR TO PLACING STONE.
6. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH
WILL PREVENT TRACKING OR FLOWING ONTO RIGHTS-OF-WAY. THIS MAY REQUIRE
PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND. ALL
SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS-OF-WAY
SHALL BE REMOVED IMMEDIATELY.
7. PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER
EACH SIGNIFICANT STORM EVENTS.
STONE AGGREGATE
CONSTRUCTION ENTRANCE
DETAIL
NOT TO SCALE
11.
EROSION & SEDIMENT CONTROL SHALL BE IN ACCORDANCE WITH
WVDEP STORMWATER CONSTRUCTION PERMIT REQUIREMENTS
SEE WEBSITE:
12.
PER 64CSR47-4.2.s.5.B, IF A HORIZONTAL SEPARATION OF 10 FEET
BETWEEN THE WATER AND SEWER LINES CANNOT BE MAINTAINED,
THEN A VERTICAL SEPARATION OF 18-INCHES (BOTTOM OF WATER
LINE ABOVE TOP OF SEWER LINE) MUST BE MAINTAINED. IF EITHER
REQUIREMENTS CANNOT BE MET, THEN THE SEWER LINE MUST BE
CONSTRUCTED SO THAT: (1) THE 2 LINES WILL CROSS BETWEEN JOINTS,
(2) THE SEWER LINE WILL BE ENCASED (NON-CONCRETE ENCASEMENT)
FOR A MINIMUM OF 10 FEET ON EITHER SIDE OF THE CROSSING, (3) AND
THE SEWER LINE WILL BE CONSTRUCTED OF THE SAME PRESSURIZED-
TYPE PIPE AS THE WATER LINE AT THE CROSSING.
TO POST
MIN.
MIN.
MIN.
FLOW
18"
42"
24"
POST (2" X 2" NOMINAL)
SILT FENCE FABRIC
ANCHORED IN TRENCH
AND FIRMLY ATTACHED
6" x 6"
TRENCH
DROP INLET
PLAN
SECTION 'A'
STANDARD DROP INLET PROTECTION
DETAIL
NOT TO SCALE
DROP INLET
CROSS BRACE
(2" X 2" NOMINAL)
NOTE: THE DANDY SACK WILL BE MANUFACTURED IN THE U.S.A. FROM A WOVEN
MONOFILAMENT FABRIC THAT MEETS OR EXCEEDS THE FOLLOWING SPECIFICATIONS:
* NOTE: ALL DANDY SACKS CAN BE ORDERED WITH OUR OPTIONAL OIL ABSORBENT PILLOWS.
EROSION & SEDIMENT
CONTROL DETAILS
JCW LAS
MEDIUM TO COURSE
6 X 6 # 10 WIRE MESH
COMPACTED SUBGRADE
4" COMPACTED
BROOM FINISH
CONTRACTION JOINT @ 5' C/C
X X X X
EXPANSION JOINT @ BUILDING
NO SCALE
EXPANSION JOINT
1/2" JOINT FILLER &
SEALANT
FACE OF BUILDING
SIDEWALK
SIDEWALK DETAIL
GEOTEXTILE FABRIC
4" ASPHALT
BASE COURSE
1" ASPHALT
WEARING COURSE
6" AGGREGATE
BASE COURSE
PAVEMENT DETAIL
1. EXISTING UNDERGROUND UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS
ACCORDING TO THE BEST AVAILABLE INFORMATION. THEIR LOCATIONS ARE
INTENDED TO BE USED AS A GUIDE AND CANNOT BE GUARANTEED ACCURATE. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE AFFECTED UTILITY
COMPANY TO NOTIFY THEM OF THE WORK TO TAKE PLACE AND COORDINATE
LOCATIONS OF THEIR FACILITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITY
LINES.
3. ALL BUILDING/ROOF DRAINS SHALL BE CONNECTED TO THE STORM WATER SYSTEM
OR DISCHARGED ONTO THE GROUND SURFACE AS SHOWN IN THE PLANS.
4. THE CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO CONTROL SOIL
EROSION AND SEDIMENTATION THROUGHOUT THE COURSE OF THE PROJECT. SEE
EROSION AND SEDIMENT CONTROL PLAN.
5. MAINTAIN TRAFFIC DURING UTILITY CONNECTION WORK THAT IMPACTS ANY TRAVEL
WAY PER WVDOT "MANUAL ON TEMPORARY TRAFFIC CONTROL FOR STREETS AND
HIGHWAYS", LATEST EDITION.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ALL NECESSARY
PERMITS INCLUDING FEES PRIOR TO CONSTRUCTION UNLESS NOTED OTHERWISE.
7. ALL NON-PAVED AREAS SHALL BE GRADED AND SODDED UNLESS NOTED
OTHERWISE.
8. ALL STORM WATER PIPES SHALL BE PVC PIPE AND SHALL BE BACKFILLED PER
MANUFACTURER'S SPECIFICATIONS UNLESS NOTED OTHERWISE.
9. ALL EROSION AND SEDIMENT CONTROL PRACTICES SHALL MEET THE STANDARDS
AND SPECIFICATIONS OF THE WVDEP.
10. BUILDINGS, STRUCTURES AND OTHER ITEMS SHOWN TO DEMOLISHED SHALL BE
REMOVED IN THEIR ENTIRETY INCLUDING FOUNDATIONS UNLESS NOTED
OTHERWISE. THIS MATERIAL SHALL BECOME THE PROPERTY OF THE CONTRACTOR
AND SHALL BE DISPOSED OF AT AN APPROVED FACILITY, UNLESS NOTED
OTHERWISE.
11. ANY SUBGRADE AREAS THAT CANNOT BE COMPACTED TO THE REQUIRED DENSITY
SHALL BE OVER-EXCAVATED AND BACKFILLED WITH COMPACTED AGGREGATE
STONE AS DIRECTED BY THE ENGINEER.
12. WINTERIZATION - ANY DISTURBED AREA THAT IS NOT GOING TO BE WORKED FOR 15
DAYS OR MORE MUST BE SEEDED AND MULCHED BEFORE NOVEMBER 1 OR MUST
HAVE A DORMANT SEEDING OR MULCH COVER APPLIED BETWEEN NOVEMBER 1 AND
MARCH 1.
13. NO EXCAVATED AREAS SHALL BE LEFT OPEN ADJACENT TO THE TRAVELED WAY
DURING NON-WORKING HOURS.
SITE GENERAL NOTES
PVC BEDDING DETAIL
TYPICAL CONCRETE CURB DETAIL
TO FLEXIBLE PAVEMENT)
(NOT REQD. WHEN CURB IS ADJACENT
6"
PREFORMED JOINT MATERIAL, 705.03
JOINT SEALER
1/4" R.
1"
5 1/2"
1/2"
FINISHED GRADE
COMPACTED SUBGRADE
3" R.
6"
CONCRETE CURB
1.
2.
EXTEND AGGREGATE SUBBASE
SUFFICIENT WIDTH BEHIND CURB
TO ACCOMODATE EXTRUSION
MACHINE.
ALL CURBING TO BE BACKED
WITH SOIL TO PROVIDE SUPPORT
PRIOR TO PAVING.
GENERAL NOTES
AGGREGATE SUBBASE
(3) VARIABLE SUMP DEPTH
ACCORDING TO PLANS
(6" MIN. BASED ON
MANUFACTURING REQ.)
4" MIN
MINIMUM PIPE BURIAL
DEPTH PER PIPE
MANUFACTURER
RECOMMENDATION
(MIN. MANUFACTURING
REQ. SAME AS MIN. SUMP)
(3) VARIABLE INVERT HEIGHTS
AVAILABLE (ACCORDING TO
PLANS/TAKE OFF)
1 - GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE
70-50-05, WITH THE EXCEPTION OF THE BRONZE GRATE.
2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05
3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS.
RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS.
SEE DRAWING NO. 7001-110-065
4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO
ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL),
N-12 HP, & PVC SEWER.
5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE
MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
(4) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE:
4" - 15" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL,
ADS/HANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), PVC C900/C905, CORRUGATED & RIBBED PVC
(1, 2) INTEGRATED DUCTILE IRON
FRAME & GRATE TO MATCH BASIN O.D.
18" MIN WIDTH GUIDELINE
8" MIN THICKNESS GUIDELINE
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II
MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR
SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED
UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR
GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE
DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS,
TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS.
SEE DRAWING NO. 7001-110-111 FOR NON TRAFFIC INSTALLATION.
(5) ADAPTER ANGLES
VARIABLE 0° - 360°
ACCORDING TO PLANS
NYLOPLAST YARD DRAIN
NO SCALE
P
O
S
T
A
C
I
N
G
A
R
L
G
E
N
D
48" HIGH DENSITY ORANGE
POLYETHELENE SAFETY FENCE
WIRE OR ZIP TIES TO SECURE
SAFETY FENCE TO POST
STAKES: 72" T-POST DRIVEN
FINISHED GRADE
20" MIN. BELOW GRADE
48" Safety Fence, 72" T-Posts
SENSITIVE AREA PROTECTION DETAIL
SAF12 48" ORANGE FENCE, 12 FEET O.C.
LEGEND
SAF10 48" ORANGE FENCE, 10 FEET O.C.
1. ALL SENSITIVE AREAS SHALL BE PROTECTED AS PER PLAN.
2. ALL TREES IN THE CONSTRUCTION AREA NOT SPECIFICALLY DESIGNATED FOR REMOVAL SHALL BE
PRESERVED AND PROTECTED WITH HIGH VISIBILITY FENCE AS PER PLAN.
3. WHEN PRACTICABLE, INSTALL HIGH VISIBILITY 3 FEET OUTSIDE OF THE DRIP LINE OF THE TREE.
4. SAFETY FENCE SHOULD BE FASTENED SECURELY TO THE T-POSTS.
5. THE FENCING MUST REMAIN IN PLACE DURING ALL PHASES OF CONSTRUCTION; ANY CHANGE OF THE
PROTECTIVE FENCING MUST BE APPROVED.
SAF9 48" ORANGE FENCE, 9 FEET O.C.
SAF8 48" ORANGE FENCE, 8 FEET O.C..
SAF7 48" ORANGE FENCE, 7 FEET O.C.
SAF6 48" ORANGE FENCE, 6 FEET O.C.
SAF11 48" ORANGE FENCE, 11 FEET O.C..
NO SCALE
GEOTEXTILE FABRIC
6" AGGREGATE
BASE COURSE
AGGREGATE PAD DETAIL
NO SCALE
GRATE OPTIONS LOAD RATING PART # DRAWING #
PEDESTRIAN MEETS H-10 1599CGP 7001-110-207
AGGREGATE
NO SCALE NO SCALE
NO SCALE
NO SCALE
DOWNSPOUT CONNECTION
NO SCALE
DOWNSPOUT
PVC ADAPTER
6" PVC PIPE
FINISHED GRADE
DOWNSPOUT SPLASH BLOCK
NO SCALE
DOWNSPOUT
FINISHED GRADE
PRE-CAST CONCRETE
SPLASH BLOCK
SLOPE TO DRAIN
20" MIN.
SITE DETAILS
JCW RSS
| G101 TITLE SHEET 100% |
| G102 Abbreviations and Code Data 100% |
| G103 Life safety Plan 100% |
| RRTP 100% - Site Drawings - 7-31-17 |
| RRTP 100% - Structural Drawings - 7-25-17 |
| A101 Floor Plans |
| A102 Basement Plan 100% |
| A103 Enlarged Floor Plan 100% |
| A104 Enlarged Floor Plan 100% |
| A105 SECOND Floor Plan 100% |
| A106 Roof Plan 100% |
| A107 Reflected Ceiling Plan 100% |
| A108 Reflected Ceiling Plan 100% |
| A201 Elevations 100% |
| A301 Sections |
| A302 Sections |
| A303 Sections |
| A304 Sections |
| A401 Enlarged Toilet Plans 100% |
| A402 Casework 100% |
| A403 Casework 100% |
| A501 WALL TYPES 100% |
| A601 DETAILS 100% |
| A602 FIN SCH 100% |
| A701 Elevator Layout 100% |
| Plmg Rev Final CD 07-27-2017 |
| Sheets and Views |
| P0-P001 |
| P1-P101 |
| P2-P102 |
| P2-P103 |
| P2-P104 |
| P2-P105 |
| P5-P501 |
| P5-P502 |
| P5-P503 |
| P5-P504 |
| P5-P505 |
| P0-P601 |
| P0-P602 |
| Mech Rev Final CD 07-27-2017 |
| Sheets and Views |
| M0 & M6-M001 |
| MH-MH101 |
| MH-MH102 |
| MH-MH103 |
| MH-MH104 |
| M5-M501 |
| M5-M502 |
| M0 & M6-M601 |
| M0 & M6-M602 |
| M0 & M6-M603 |
| M7-M701 |
| M7-M702 |
| M7-M703 |
| Elec Rev Final CD 07-27-2017 |
| Sheets and Views |
| E0-E001 |
| EP-EP101 |
| EP-EP102 |
| EP-EP103 |
| EP-EP104 |
| EL-EL101 |
| EL-EL102 |
| EL-EL103 |
| EL-EL104 |
| ES-ES101 |
| ES-ES102 |
| ES-ES103 |
| ES-ES104 |
| E5-E501 |
| E6-E601 |
| E6-E602 |
| E7-E701 |
| E8-E801 |
RRTP BLDG FIRE SPRINKLER 8-18-17
File details come from the government source that posted it. Updated .