Attachment C.2. Wilkes-Barre FD SD Excel report.xlsx
XLSX spreadsheet 16 KB Posted
- Solicitation number
- 36C24425Q0633
About this file
This file is an Excel report detailing fire and smoke damper inspections at the Wilkes-Barre VA Medical Center. The comprehensive report contains 176 entries documenting the status of various fire dampers and smoke dampers across multiple floors and locations, with each entry noting specific details such as location, task number, compliance status, and any additional observations. The majority of entries are marked as "Compliant" and "Closed", with 16 entries identified as "Non-Compliant" and remaining open, requiring further investigation or remediation. Key non-compliance issues include MEP obstructions, inability to access dampers, high air volume preventing testing, dampers located in non-rated barriers, and challenges with reaching or testing specific damper locations.
The related federal contract opportunity (Solicitation Number: 36C24425Q0633) is a Service-Disabled Veteran Owned Small Business (SDVOSB) set-aside solicitation for Fire and Smoke Barrier Inspections/Repairs and Fire and Smoke Damper Inspections/Repairs at the Wilkes-Barre VA Medical Center. The solicitation uses NAICS Code 541350 with a business size standard of $11.5 million, and the Product Service Code is H912. The contract will be issued on Standard Form 1449, with the Service Contract Act Wage Determinations applying. Potential vendors must be registered in the System for Award Management (SAM) database, and all questions must be submitted by May 29th, 2025, at 3:00 PM Eastern Time to the Contracting Office.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment C.1 Wilkes-Barre FD SD PDF report_Redacted.pdf | ||
| 36C24425Q0633 0001 Amendment Document.docx | DOCX document | |
| 36C24425Q0633 QA Sheet 05-29-2025.docx | DOCX document | |
| 36C24425Q0633 Combined Notice.docx | DOCX document | |
| Attachment B Life Safety Drawings_Redacted.pdf | ||
| 36C24425Q0633_1 Rev2 Solicitation Document.docx | DOCX document | |
| P07 WD 2015-4239 Rev28 dated 12-23-2024.pdf | ||
| Attachment A - Records Management Requirements.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Task Details
| Location | Stamp | Description | Status | Task # |
| C11-06 Men's bathroom | FD | 1-11-FD-1107, Compliant, | closed | 1 |
| C11-10 women's bathroom | FD | 1-11-FD-1110, Compliant, | closed | 2 |
| C11-13A bathroom | FD | 1-11-FD-1103, Compliant, | closed | 3 |
| C11-17 bathroom | FD | 1-11-FD-1104, Compliant, | closed | 4 |
| 13-003 | FD | 1-13-FD-1096. Compliant | closed | 5 |
| 13-001 | FD | 1-13-FD-1095, Compliant, Decommissioned, |
| Notes; Damper is not in a rated barrier | closed | 6 | |||
| C11-22A bathroom | FD | 1-11-FD-1105, Compliant, | closed | 7 | |
| C10-28 | FD | 1-10-FD-10F01 or 1111, Compliant, | closed | 8 | |
| C11-31 | FD | 1-11-FD-1101, Compliant, |
| This damper was not on our hard copy list | closed | 9 | |
| C9-45 | FD | 1-9-FD-0901, Compliant, |
| Found damper decommissioned but it is located in a rated barrier, recommissioned, | closed | 10 | |
| C9-58A | FD | 1-9-FD-1219, Compliant, Decommissioned, |
| Damper is in a unrated barrier, | closed | 11 | |
| C9-58A | FD | 1-9-FD-1217, 1218, Compliant, Decommissioned, |
| Both dampers are accessed through the same panel, both dampers are in a non-rated barrier, | closed | 12 | |||
| C8-70D | FD | 1-8-FD-1045, Compliant, | closed | 13 | |
| C8-70D | FD | 1-8-FD-1044, Compliant, Decommissioned, |
| Damper is in a non-rated barrier, | closed | 14 | |||
| C8-54A | FD | 1-8-FD-8F07, Compliant, | closed | 16 | |
| C8-69 | FD | 1-8-FD-1157, Compliant, Decommissioned, | closed | 18 | |
| C8-68 | FD | 1-8-FD-1155, Compliant, Decommissioned, | closed | 19 | |
| C8-68 | FD | 1-8-FD-1156, Compliant, Decommissioned, | closed | 20 | |
| C8-32 | FD | 1-8-FD-1159, Compliant, | closed | 21 | |
| C8-43A | FD | 1-8-FD-1209, Compliant, | closed | 22 | |
| C8-45 women bathroom | FD | 1-8-FD-1210, Compliant, | closed | 23 | |
| C8=20 Hallway | SD | 1-8-SD-1043, Compliant, Decommissioned, | closed | 24 | |
| C8-15 in hall to Fire Door | SD | 1-8-SD-1056, Compliant, Decommissioned, | closed | 27 | |
| C7-28 | FD | 1-7-FD-1160, Compliant, | closed | 28 | |
| C7-40 bathroom | FD | 1-7-FD-1164, Compliant, Decommissioned, |
| Notes: Damper is in a non-rated barrier, | closed | 29 | |
| C7-41 | FD | 1-7-FD-1163, Compliant, Decommissioned, |
| Notes: Fire Damper is in a non-rated barrier, | closed | 30 | |||
| C7-43B inside above door | FD | 1-7-FD-1018, 1019, Compliant, | closed | 31 | |
| C7-30 back right corner | FD | 1-7-FD-1136, Compliant, | closed | 32 | |
| C7-20 middle of double doors | FD | 1-7-FD-1135, Non-Compliant, |
| Notes: Fusion tab is a wired explosive charge device, Two hour Fire Barrier, Brent is inquiring about removing this system and replacing with a gravity system | open | 33 | |||
| C7-21 hallway across from this door | FD | 1-7-FD-1133, Compliant, | closed | 34 | |
| C7-15 | FD | 1-7-FD-1161, Compliant, | closed | 35 | |
| C6-67D | FD | 1-6-FD-1090, 1091, Compliant, | closed | 36 | |
| C6-67E | FD | 1-6-FD-1088, Compliant, | closed | 37 | |
| C6-67E | FD | 1-6-FD-1089, Compliant, | closed | 38 | |
| C5-74A | FD | 1-5-FD-1126, 1127, Compliant, |
| closed | 39 | |||
| C5-16 | FD | 1-5-FD-1165, Compliant, | closed | 40 |
| A5-04 right and all the way back | FD | 1-5-FD-O5F53, Non-Compliant, |
| Notes: Non-rated barrier, unable to access for decommissioning, | open | 42 | |||
| A5-03 | FD | 1-5-FD-1128, 1129, Compliant, | closed | 43 | |
| C5-49 office | FD | 1-5-FD-O5F68, Compliant, Decommissioned, |
| Notes: Non-rated barrier, | closed | 44 | |
| C5-49A | FD | 1-5-FD-1131, Compliant, |
| Notes: this damper was not on the inventory sheet, | closed | 45 | |
| C5-49C door by refrigerator | FD | 1-5-FD-O5F11, O5F10, Compliant, Decommissioned, |
| Notes: Not on inventory sheet, in Non-rated barrier, | closed | 46 | |
| C5-51D | FD | 1-5-FD-C5-51D FD, Compliant, Decommissioned, |
| Notes: This Damper is not identified on the inventory list and has no ID tag, it is in a unrated barrier | closed | 48 | |
| C5-51D | FD | 1-5-FD-1211, Non-Compliant, |
| Notes: Air flow was very high,needs to be shut down to test, 12/13/22 HVAC unable to shut down air flow on this duct at this time | open | 49 | |||
| C5-25 | FD | 1-5-FD-1225, Compliant, | closed | 50 | |
| N5-74 | FD | 1-5-FD-5F75, 5F76, 5F78, Compliant, | closed | 51 | |
| A4-03 | FD | 1-4-FD-1124, Compliant, | closed | 52 | |
| A4-03 | FD | 1-4-FD-1125, Compliant, Decommissioned, |
| Notes: Damper is in a Non-rated Barrier, | closed | 53 | |||
| C4-30 | FD | 1-4-FD-1171, 1172, 1173, Compliant, | closed | 54 | |
| C4-51D | FD | 1-4-FD-1212, Compliant, | closed | 55 | |
| C4-54 | FD | 1-4-FD-1285, 1286, Compliant, | closed | 56 | |
| C3-22 | FD | 1-3-FD-1195, Compliant, |
| Notes: Notes from the Inventory list as well as on the ID tag indicate that this Damper has been decommissioned | closed | 57 | |||
| C3-24 | FD | 1-3-FD-1284, Compliant, | closed | 58 | |
| FD | 1-3-N/A,Decommissioned, |
| Notes: According to notes on the Inventory list and the ID tag this duct is no longer in use and the damper has been decommissioned | closed | 59 | |||
| A3-03 hallway | FD | 1-3-FD-1271, Compliant, | closed | 60 | |
| C2-39C | FD | 1-2-FD-1061, 1062, Compliant, | closed | 61 | |
| C2-34 Hallway Dbl door | FD | 1-2-FD-1015, 1016, 1017, Non-Compliant, |
| Notes: All dampers have MEP impeding access, dampers are also very far from the access panels, damper 1017 is not on the inventory list | open | 62 | |||
| C2-27A Fire Extinguisher | SD | 1-2-SD-1013, Compliant, | closed | 63 | |
| C2-33D Hallway | FD | 1-2-FD-1060, Non-Compliant, |
| Notes: MEP is obstructing access panel | open | 64 | |||
| C2-33B | FD | 1-2-FD-1059, Compliant, | closed | 65 | |
| C2-33A | SD | 1-2-SD-1057, Compliant, | closed | 66 | |
| N2-95 Hall Dbl Doors | FD | 1-2-FD-1252, Non-Compliant, |
| Notes: Damper is out of reach from access panel, MEP’s obstructing access | open | 67 | |
| C2-33C Restroom | FD | 1-2-FD-1058, Non-Compliant, |
| Notes: MEP obstructing access, | open | 68 | |
| C8-78 Hallway | SD | 1-8-SD-1132, Non-Compliant, |
| Notes: unable to reach actuator | open | 69 | |
| C8-78 | FD | 1-8-FD-1092, Non-Compliant, |
| Notes: Damper is in non-rated barrier and should be decommissioned, cannot access due to MEP, | open | 70 | |||
| C3-49A | FD | 1-3-FD-1198, Compliant, | closed | 71 | |
| C2-09 | FD | 1-2-FD-1255, Compliant, | closed | 72 | |
| 2-227 | FD | 1-2-FD-1189, Compliant, | closed | 73 | |
| 2-226 bathroom | FD | 1-2-FD-1192, 1191, Compliant, | closed | 74 | |
| A2-19 | FD | 1-2-FD-1122, Compliant, | closed | 75 | |
| A2-19 | FD | 1-2-FD-1123, Compliant, Decommissioned, |
| Notes: Damper is in a Non-rated Barrier | closed | 76 | |||
| A2-18 | FD | 1-2-FD-1248, Compliant, | closed | 77 | |
| A2-46 | FD | 1-2-FD-1250, Compliant, | closed | 78 | |
| A2-18 | FD | 1-2-FD-1251, Compliant, | closed | 79 | |
| A2-46 | FD | 1-2-FD-1247, Compliant, | closed | 80 | |
| C2-47 Hallway Dbl Door | SD | 1-2-SD-1253, Compliant, | closed | 81 | |
| C2-47 Hallway Dbl Door | SD | 1-2-SD-1288, Compliant, |
| closed | 82 | |||
| C1-04A | FD | 1-1-FD-1187, Compliant, | closed | 83 |
| A1-03 | FD | 1-1-FD-1120, Compliant, | closed | 84 |
| A1-03 | FD | 1-1-FD-1121, Compliant, Decommissioned, |
| Notes: Damper is in a non-rated Barrier | closed | 85 | |||
| C1-61 Bathroom Men | FD | 1-1-FD-1258, Compliant, | closed | 86 | |
| C1-60 Bathroom W | FD | 1-1-FD-1260, Compliant, | closed | 87 | |
| A1-45 Bathroom W | FD | 1-1-FD1256, Compliant, | closed | 88 | |
| A1-35 opposite counter | FD | 1-1-FD-1216, Compliant, |
| closed | 89 | |||
| A1-31B Dbl Door | SD | 1-1-SD-1008, 1009, 1010, Compliant, | closed | 90 |
| A1-73 Hallway | FD | 1-1-FD-1215, Non-Compliant, |
| Notes: Damper is out of reach, | open | 91 | |
| N1-84 Hallway Dbl Doors | SD | 1-1-SD-1185, 1012, 1011, Compliant, |
| closed | 92 | |||
| N1-89A | FD | 1-1-FD-1214, Compliant, | closed | 93 |
| N1-89A | FD | 1-1-FD-1213, Compliant, |
| Notes: Alarm was isolated and damper tested, | closed | 94 | |
| C1-35A | FD | 1-1-FD-1186, Non-Compliant, |
| Notes: Damper is out of reach, | open | 95 | |||
| CG-8B | FD | 1-G-FD-1201, Compliant, | closed | 96 | |
| AG-19 Mech rm inside AG-20 | FD | 1-G-FD-BF27, Compliant, |
| Notes: Damper has been replaced, | closed | 97 | |||
| AG-19 Mech rm inside AG-20 | FD | 1-G-FD-1203, Compliant, | closed | 98 | |
| C10-25 Hallway Dbl door | SD | 1-10-SD-10S02, Compliant, |
| closed | 99 | |
| Floor 11 elevator room 15-17 | FD | 1-11-FD-1063, Compliant, |
| Notes: dampers Fusion Tab was missing, replaced | closed | 100 | |||
| Floor 11 elevator room 15-17 | FD | 1-11-FD-1064, Compliant, | closed | 101 | |
| Floor 11 elevator room 15-17 | FD | 1-11-FD-1065, Compliant, | closed | 102 | |
| C8-45C | FD | 1-8-FD-1020, 1021, Compliant, | closed | 103 | |
| C3-17A | FD | 1-3-FD-1268, Compliant, |
| Notes: Fixed, | closed | 104 | |||
| C3-29 | FD | 1-3-FD-1194, Compliant, | closed | 105 | |
| A3-03 | SD | 1-3-SD-w3LB, Compliant, |
| Notes: Not on inventory list, | closed | 106 | |||
| A3-02 | FD | 1-3-FD-1168, Compliant, | closed | 107 | |
| A3-02 | FD | 1-3-FD-1269, Non-Compliant, |
| Notes: Damper is located in a non-rated barrier, MEP is blocking access to decommission | open | 108 | |
| C1-22A Hallway opposite wall | FD | 1-1-FD-1257, Non-Compliant, |
| Notes: MEP obstructing access | open | 109 | |
| 4-116 Dialysis Storage | FD | 1-4-FD-1079, 1080, 1081, 1082, 1083, 1084, Compliant, |
| closed | 110 | |||
| 4-102 | FD | 1-4-FD-1085, Compliant, | closed | 111 |
| A4-51 | FD | 1280, Non-Compliant, |
| Notes: Hard ceiling access panel in ceiling is locked, cannot locate key | open | 112 | |||
| A4-60 | FD | 1-4-FD-1263, 1264, 1265, Compliant, | closed | 113 | |
| A4-60 | FD | 1-4-FD-1268-04F125, Non-Compliant, |
| Notes: there is no ID tag on the damper, airflow needs to be stopped to test, located in OR area and airflow could not be stopped at this time | open | 114 | |
| A4-60 | FD | 1-4-FD-1267-04F40, Compliant, |
| Notes: no ID tag on the damper, | closed | 115 | |
| A4-81 | FD | 0000, Non-Compliant, |
| Notes: there is an old ID tag on damper and no id# on inventory list, damper is difficult to access and very high volume air flow, in OR area and unable to shut down airflow at this time | open | 116 | |||
| A4-81 Hallway right of door | FD | 1-4-FD-1266, Compliant, | closed | 117 | |
| A4-58 | FD | 1-4-FD-1261, 1262, Compliant, | closed | 118 | |
| A4-28 | FD | 1-4-FD-1179, Non-Compliant, |
| Notes: Very high volume air flow, damper is in ICU cannot shut down air flow at this time | open | 119 | |
| A4-29 | FD | 1-4-FD-1178, Non-Compliant, |
| Notes: Very high volume air flow, damper is in ICU, cannot shut down air flow at this time | open | 120 | |||
| 4-126 Hallway corner floor | FD | 1-4-FD-1040, Compliant, | closed | 121 | |
| Across from Gold Elevators, left of the double doors to Hemodialysis | FD | 1-4-FD-1041, 1042, Compliant, | closed | 122 | |
| 3-107 Hallway Dbl door | SD | 27-3-SD-1230, Compliant, | closed | 124 | |
| C3-116 Hallway above door | FD | 27-3-FD-1232, compliant, Decommissioned, | closed | 125 | |
| 3-122 Restroom/Shower | SD | 27-3-SD-1231, Compliant, |
| closed | 126 | |
| 3-127 Hallway Dbl door | SD | 27-3-SD-1233, Compliant, |
| closed | 127 | |
| 3-128A Bathroom | SD | 27-3-SD-1235, Compliant, |
| closed | 129 | |||
| AG-51 | FD | 1-G-FD-AG-51, Compliant, | closed | 130 |
| C1-46B | FD | 1-1-FD-1183, 1184, Compliant, | closed | 131 |
| 2-106 Hallway Dbl Door | SD | 27-2-SD-1238, Compliant, | closed | 132 |
| 2-126 Hallway Dbl Door | SD | 27-2-SD-1240, Compliant, |
| closed | 134 | |
| 2-141 Med Rm | SD | 27-2-SD-1242, Compliant, |
| closed | 135 | |
| CG-20A | SD | 1-G-SD-1202, Non-Compliant, |
| Notes: unable to get a visual of the actuator, 20’ above the floor | open | 136 | |||
| CG-23 | FD | 1-G-FD-1007, Compliant, | closed | 137 | |
| C11-05 Bathroom | FD | 1-11-FD-1108, Compliant, |
| closed | 138 | |
| C5-25 Hallway Dbl Door | FD | 1-5-FD-1167, Compliant, |
| Notes: Damper has been replaced and tested | closed | 139 | |||
| C5-25 Hallway Dbl Door | FD | 1-5-FD-1166, Compliant, | closed | 140 | |
| C5-49C door by refrigerator | FD | 1-5-FD-05F12, 05F13, Compliant, Decommissioned, |
| Notes: non rated barrier | closed | 141 | |
| 3-106A Bathroom | SD | 27-3-SD-1237, Compliant, |
| closed | 142 | |
| CG-60 supply chain Storage | FD | 1-CG- FD CG-60-3, Compliant, |
| Notes: Fire Damper installed and tested, access panel installed | closed | 143 | |
| CG-60 Hallway | FD | 1-G-FD-CG60-2, Compliant, |
| Notes: Damper has been replaced, and access panel installed, | closed | 144 | |
| CG-60 ante room | FD | 1-CG-FD CG-60-1, compliant, |
| Notes: Larger access panel has been installed, | closed | 145 | |
| CG-60 Hallway | FD | 1-CG- FD CG-60, compliant, |
| Notes: Access panel has been replaced with a larger panel, | closed | 146 | |
| CG-44 Dry Storage | FD | 1-CG-FD CG-44,, Compliant, |
Notes: Fixed,
| closed | 147 | |||
| FD | 1-8-FD-1158, Compliant, Decommissioned, | closed | 151 | |
| N1-93 | SD | 1-1-SD-?, Damper does not have a ID number, Compliant, |
| NBEL26 | closed | 155 | |||
| NG-97 | FD | 1-G-FD-1206, Compliant, | closed | 171 | |
| A3-03 | FD | 1-3-FD-1150, Compliant, | closed | 172 | |
| A3-03 | FD | 1-3-FD-1149, Compliant, | closed | 173 | |
| A3-03 | FD | 1-3-FD-1148, Compliant, | closed | 174 | |
| A3-03 | FD | 1-3-FD-1147, Compliant, | closed | 175 | |
| A3-03 | FD | 1-3-FD-1146, Compliant, | closed | 176 |