Signage: Lessor will furnish, install, and maintain signage.
A. Provide "Interior Room Signs with Insert” for every staff and patient room.
B. The “Secondary Room Sign with Insert” is to be used for all other rooms such as Electric, IT
Closet, Utility, and similar rooms and will be finalized during the post-award design meeting.
C. The “Restroom Signs” are to be used for public restrooms and all staff and patient restrooms.
D. Way-finding signage and mandatory signage will be finalized at the post-award meeting E. The “Instructional Signs” will be used as needed once the final CBOC plan is approved.
F. Text for all signs shall be approved by VA. As stated in Exhibit B- ASR, the room name and numbering system will be developed as part of the DIDs.
G. Exterior signage locations will be finalized at post-award design meeting.
Exhibit X
12/2012 Page 4-6-1
Exterior Signs
Size Sign Face:
1524 mm H x 3658 mm W x 305mm D (5' 0" H x 12' 0" W x 1’ 0” D)
Description & Use Internally illuminated large horizontal free standing monument sign for identifying a medical center or the medical center’s main entrance drive.
The base can be constructed of concrete or other masonry material in a color and texture that will provide a coordinated architectural look with the building finishes of the medical center.
Message Configuration (Refer to message layout drawing for dimensions)
Specific message configuration will vary depending on the particular name of a facility. Variations to the presentation of a facility’s name will need special approval from Washington DC.
Graphic Process Illuminated, routed out copy backed with white translucent acrylic.
Colors Text: White Background: Refer to color chart Accent: Refer to color chart
Recommendations Position sign so drivers have a clear, unobstructed view of the sign. Keep landscaping around the sign low and position sprinklers so they project away from the sign.
On-off illumination of sign can be controlled through the use of a timer, manual or photoelectric switch.
Consult with sign fabricator at time of order for appropriate method to use.
On-off illumination of sign can be controlled through the use of a timer, manual or photoelectric switch.
Consult with sign fabricator at time of order for appropriate method to use.
Site Monument
EI-01.01
Message Layout B &D
Message Layout C
Message Layout E
Tomah VA Medical Center
VA New England Health Care Network
Tomah VA Medical Center Phoenix
Message Layout A Message Layout B
Message Layout C
Message Layout FMessage Layout E
Message Layout D
William S. Middleton Memorial Veterans Hospital Madison VA Great Lakes Health Care Network
Baltimore VA Medical Center VA Maryland Health Care System
VA Capitol Health Care Network
VA Medical Center Regional Office White River Junction VA New England Health Care Network
Tomah VA Medical Center
VA Great Lakes Health Care Network
VA Regional Office Phoenix
VA Outpatient Clinic Appleton
VA Great Lakes Health Care Network
VA Capitol Health Care Network
Baltimore VA Medical Center VA Maryland Health Care System
12/2012 Page 4-6-2
Site Monument
EI-01.01
Message Layout C
Message Layout E
1524.0 mm (5'-0")
214.7 mm (8 1/2")
120.9 mm (4 3/4")
120.9 mm (4 3/4")
74.8 mm (3")
1524.0 mm (5'-0")
203.2 mm (8")
63.5 mm (2 1/2")
127.0 mm (5")
609.6 mm (2'-0")
Message Layout A & F
303.4 mm (1'-0")
25.4 mm (1")
76.2 mm (3")
25.4 mm (1")
533.4mm (1'-9")
214.7 mm (8 1/2")
63.5 mm (2 1/2")
214.7 mm (8 1/2")
1524.0 mm
(5'-0")
3657.6 mm (12'-0")
203.2 mm (8")
120.8 mm (4 3/4")
120.8 mm (4 3/4")
88.9 mm (3 1/2")
1524.0 mm (5'-0")
Message Layout B & D
120.9 mm (4 3/4")
120.9 mm (4 3/4")
74.8 mm (3")
88.9 mm (3 1/2")
95.3 mm (3 3/4")
127.0 mm (5")
63.5 mm (2 1/2")
2'-9"
533.4mm (1'-9")
214.7 mm (8 1/2")
120.8 mm (4 3/4")
203.2 mm (8")
2'-9"
533.4mm (1'-9")
2'-9"203.2 mm (8")
533.4mm (1'-9")
2'-9"
7"
7"
7"
7"
12/2012 Page 4-6-5
Site Monument
EI-01.03
Size Sign Face:
1219 mm H x 2438 mm W x 305 mm D (4' 0" H x 8' 0" W x 1’ 0” D)
Description & Use Internally Illuminated small horizontal free standing monument sign for identifying a medical center where there is a space limitation.
This sign can also be used to identify secondary drive entrances to the medical center.
The base can be constructed of concrete or other masonry material in a color and texture that will provide a coordinated architectural look with the building finishes of the medical center.
Message Configuration (Refer to message layout drawing for dimensions)
Specific message configuration will vary depending on the particular name of a facility. Variations to the presentation of a facility’s name will need special approval from Washington DC.
Graphic Process Illuminated, routed out copy backed with white translucent acrylic.
Colors Text: White Background: Refer to color chart Accent: Refer to color chart
Recommendations Position sign so drivers have a clear, unobstructed view of the sign. Keep landscaping around the sign low and position sprinklers so they project away from the sign.
On-off illumination of sign can be controlled through the use of a timer, manual or photoelectric switch.
Consult with sign fabricator at time of order for appropriate method to use.
Department of Veterans Affairs Baltimore VA Medical Center VA Maryland Health Care System
VA Capitol Health Care Network
Department of Veterans Affairs William S. Middleton Memorial Veterans Hospital Madison
VA Great Lakes Health Care Network
Department of Veterans Affairs Tomah VA Medical Center
VA Great Lakes Health Care System
Department of Veterans Affairs VA Outpatient Clinic Appleton
VA Great Lakes Health Care System
Department of Veterans Affairs VA Regional Office Phoenix
Message Layout B
Message Layout F
Message Layout C Message Layout D
Message Layout A
Message Layout E
Message Layout A Message Layout B
Message Layout C
Message Layout FMessage Layout E
Message Layout D
William S. Middleton Memorial Veterans Hospital Madison
VA Great lakes Health Care Network
Baltimore VA Medical Center VA Maryland Health Care System
VA Capitol Health Care Network
VA Medical Center Regional Office White River Junction
VA New England Health Care Network
Tomah VA Medical Center
VA Great Lakes Health Care Network
VA Regional Office Phoenix
VA Outpatient Clinic Appleton
VA Great Lakes Health Care Network
VA Capitol Health Care Network
Baltimore VA Medical Center VA Maryland Health Care System
12/2012 Page 4-6-6
Site Monument
EI-01.03
Message Layout C
Message Layout E
63.5 mm (2 1/2")
127.0 mm (5")
609.6 mm (2'-0")
Message Layout A & F
303.4 mm (1'-0")
25.4 mm (1")
76.2 mm (3")
25.4 mm (1")
431.8mm (1'-5")
165.1 mm (6 1/2")
57.1 mm (2 1/4")
165.1 mm (6 1/2")1219.2.0 mm (4'-0")
2438.4 mm (8'-0")
152.4 mm (6")
101.6 mm (4 ")
95.2 mm (3 3/4")
76.2 mm (3 ")
Message Layout B & D
2'-3"
5 1/2"
431.8mm (1'-5")
57.1 mm (2 1/4")
127 mm (5")
1219.2.0 mm
(4'-0")
152.4 mm (6")
88.9 mm (3 1/2 ")
76.2 mm (3 ")
2'-3"
5 1/2"
76.2 mm (3 ")
57.1 mm (2 1/4")
88.9 mm (3 1/2 ")
431.8mm (1'-5")
165.1 mm (6 1/2")1219.2.0 mm (4'-0")
152.4 mm (6")
101.6 mm (4 ")
2'-3"
5 1/2"
431.8mm (1'-5")
165.1 mm (6 1/2")1219.2.0 mm (4'-0")
152.4 mm (6")
101.6 mm (4 ")
95.2 mm (3 3/4")
76.2 mm (3 ")
2'-3"
5 1/2"
12/2012 Page 4-6-23
Wall Mounted Overhead
EI-06.01
Nursing Home Care
Nursing Home Care Spinal Rehabilitation
Spinal Rehabilitation Clinic Entrance Beverly Clinic
VA Great Lakes Health Care Network
D
Size Sign Face:
610 mm H x 2438 mm W (2' 0" H x 8' 0" W)
Description & Use Internally illuminated overhead wall mounted identification sign for a stand alone building, that is not a medical center. This sign type can also be used to identify an entrance to a building.
Message Configuration (Refer to message layout drawing for dimensions)
Message Layout A, B and C are for identifying an entrance to a building.
Message Layout D is for identifying a non-medical center, stand alone building, typically off campus.
Graphic Process Illuminated, routed out copy backed with white translucent acrylic.
Colors Text: White Background: Refer to color chart
Recommendations For a stand alone non medical center building, use this type of sign when there is not place to install a free standing sign.
Use this type of sign for “titling” major building entrances that have a very high volume of patient and visitor traffic and need to be clearly distinguished.
On-off illumination of sign can be controlled through the use of a timer, manual or photoelectric switch.
Consult with sign fabricator at time of order for appropriate method to use.
12/2012 Page 4-6-24
Wall Mounted Overhead
EI-06.01
63.5 mm (2-1/2”) 127 mm (5”)
152.4 mm (6”)
179.5 mm (7”)
610 mm (2’ - 0”)
Message Layout A
Message Layout B
Message Layout C
Message Layout D
127 mm (5”)
304.8 mm (1'-0")
292 mm (11 1/2")
6.2 mm (3")
114.3 mm (4 1/2")
73.02 mm (2 7/8")
88.9 mm (3 1/2")
44.5 mm (1 3/4")
88.9 mm (3 1/2")
53.9 mm (2 1/8")
146 mm (5 3/4")
82.5 mm (3 1/4")
44.5 mm (1 3/4")
60.3 mm (2 3/8")
2438 mm (8’ - 0”)
177.8 mm (7”)
12/2012 Page 4-6-25
Wall Mounted Building Identification
EI-06.02
Building
Admissions Outpatient Rehabilitation
Building
230Outpatient Center
Outpatient Center
Size Sign Face:
914 mm H x 1219 mm W (3' 0" H x 4' 0" W)
Description & Use Internally Illuminated large wall mounted sign type that can be used to identify a building on a medical center campus. It also can be used for identification of a stand alone building that is not a medical center and there is no place to install a free standing sign.
Message Configuration (Refer to message layout drawing for dimensions)
Message Layout A is for identifying a non-medical center stand alone building, typically off campus.
Message Layout B and C are for identifying building on a medical center campus.
Graphic Process Illuminated, routed out copy backed with white translucent acrylic.
Colors Text: White Background: Refer to color chart
Recommendations For a stand alone non medical center building, use this type of sign when there is not place to install a free standing sign.
Use this type of sign for “titling” building entrances that have a very high volume of patient and visitor traffic and needs to be clearly distinguished. It also can be use on a building that is set back a considerable distance from the roadway.
Position the sign adjacent the main entrance, if possible. If the sign is not readable in this position, then locate on the corner of the building.
This large sign should not be used on small buildings or buildings with minor uses.
On-off illumination of sign can be controlled through the use of a timer, manual or photoelectric switch.
Consult with sign fabricator at time of order for appropriate method to use.
12/2012 Page 4-6-26
Wall Mounted Building Identification
EI-06.02
63.5 mm (2-1/2”)
63.5 mm (2-1/2”)
1219 mm (4-0”)
914 mm (3-0”)
101.6 mm (4”)
63.5 mm (2-1/2”)
76.2 mm (3”)
76.2 mm (3”)
76.2 mm (3”)
76.2 mm (3”)
76.2 mm (3”)
76.2 mm (3”)
63.5 mm (2-1/2”)
203.2 mm (8”)
76.2 mm (3”)
76.2 mm (3”)
254 mm (10”)
178 mm (7”)
Message Layout A
Message Layout B
Message Layout C
82.3 mm (3 1/4")
114.3 mm (4 1/2")
1/8" Rule
41.27 mm (1 5/8")
69.8 mm (2 3/4")
41.27 mm (1 5/8")
12/2012 Page 4-6-33
Dimensional Building Identification Letters
EI-09
Z
X
W
Y
Medical Center
Medical Center
WXZY
1050 mm (42")
1350 mm (56")
1800 mm (70")
2100 mm (84")
350 mm (19")
475 mm (25")
575 mm (31")
700 mm (38")
150 mm (6")
150 mm (6")
150 mm (6")
150 mm (6")
450 mm (18")
600 mm (24")
750 mm (30")
900 mm (36")
Sign Type
EI09.6
EI09.7
EI09.8
EI09.9
Size For the various sizes, refer to the adjacent table.
Description & Use Internal halo-illuminated, fabricated metal dimensional letters and logo for identifying a facility.
This sign should be placed on the medical center building in a location that is highly visible to the public.
Message Configuration (Refer to message layout drawing for dimensions)
Letters used with the logo should read “Medical Center”, “Outpatient Center” or “Veterans Affairs”.
Graphic Process Fabricated aluminum letters with internal LED lighting. Letters are pin mounted off wall to allow light to wash wall and halo illuminate letters.
Colors White, black, silver or dark bronze.
Letter to have high contrast to the building wall color or material. For example use white on red brick, not black.
Illumination color is white light.
Recommendations Large size letters and logo are intended for use on the top of the building as a skyline sign.
These letters require clear access to the back (inside) of the wall on which they will be installed.
On-off illumination of sign can be controlled through the use of a timer, manual or photoelectric switch.
Consult with sign fabricator at time of order for appropriate method to use.
12/2012 Page 4-7-27
Small Single Post Informational
EN-05.03
Freight Loading Zone
No Smoking
Area
No Parking
Authorized Vehicles Only Beyond This Point
Patient Pick Up & Drop Off Only
Freight Loading Zone
Message Layout A Message Layout B
Message Layout C Message Layout D
Size Sign face:
457 mm H X 305 mm W (1'6" H X 1'0" W)
Overall Sign High:
1829 mm (6' 0")
Description Small, non-illuminated single post identification and informational sign. This type of sign is for miscellaneous uses and can be utilized in landscape areas at the head of parking stalls, or in other locations which have space limitations. This type of sign would be placed in situations where a small sign is required.
Message Configuration (Refer to message layout drawing for dimensions)
Message configurations shown, Illustrate various adaptable uses for this particular style of sign.
Graphic Process Surface applied white reflective Vinyl.
Colors Text: White Background: Refer to color chart Post: Refer to color chart
Recommendations Position sign so drivers have a clear, unobstructed view of the sign.
When placing this type of sign near curbs or parking places, be sure the sign is set far enough back that over-hanging front and rear of automobiles do not come in contact with the sign post.
12/2012 Page 4-7-28
Small Single Post Informational
EN-05.03
Message Layout CMessage Layout B
Message Layout A
Message Layout D
12/2012 Page 4-7-53
Traffic Regulatory Signs
EN-10
EN-10.01 EN-10.02 EN-10.03
EN-10.04 EN-10.05 EN-10.06
EN-10.07 EN-10.08 EN-10.09
Size EN-10.01: Stop (R1-1): 24", 30", 36"
EN-10.02: Do Not Enter (R5-1):
30", 36"
EN-10.03: Yield (R1-2): 30", 36"
EN-10.04: Speed Limit (R2-8)
EN-10.05: Keep Right (R4-7A)
EN-10.06: One Way (R6-2L, R6-2R)
EN-10.07: No Right/Left Turn (R3- 1R, R3-2L)
EN-10.08: No U Turn (R3-4)
EN-10.09: Pedestrian Crossing (W11-2A)
Description Traffic regulatory signs
Sign Use & Application The “Manual on Uniform Traffic Control Devices for Streets and Highways” has been adopted as the standard for all Regulatory and Warning Signs used on the Department of Veterans Affairs roadways for vehicular traffic.
Message Configuration (Refer to message layout drawing for dimensions)
Text, text size, text position and color must conform with the Manual on Uniform Traffic Control Devices
(MUTCD)
Colors Text & Background: “MUTCD” standard colors;
Post: Refer to color chart.
Recommendations Display the most commonly used signs as indicated. If other Traffic Regulatory and Warning Signs are need, refer to MUTCD.
Position sign so drivers have a clear, unobstructed view of the sign.
It should be noted that the decision to use a particular traffic control device at a specific location should be made on the basis of a standard traffic engineering study of the location. Sign size should be based on traffic conditions. Where these conditions are the same, all signs of a similar type should be the same size.
12/2012 Page 4-7-54
Traffic Regulatory Signs
EN-10
EN-10.01 EN-10.02 EN-10.03
EN-10.07
EN-10.08
EN-10.04
EN-10.05
EN-10.06
EN-10.10
12/2012 Page 4-7-61
Exterior SignsEN-14 Building Entrance Door Identification
Size Sign Characters: See layout
Overall Sign Height:
1650 mm (5' 6")
Description Non-illuminated, applied vinyl letter identification sign with messages directed specifically to pedestrians.
The sign can also be used to identify buildings.
Message Configuration (Refer to message layout drawing for dimensions)
Message size and layout should adjust to the volume of information being presented. Smaller text than shown should not be used as the messages will be unreadable. Larger text than shown will result in words that may not fit on the sign.
Graphic Process First surface applied white reflective vinyl.
Colors Text: White Do not use colored vinyl.
Recommendations Position sign so pedestrians have a clear, unobstructed view of the sign.
These doors are locked from 6 p.m. to 6 a.m.
When doors are locked, use Ambulance Entrance
Smoking is only permitted outside in designated areas.
Baltimore VA Medical Center
Main Entrance Building 16
EQ EQ
m m
(5 '-6
EQ EQ
m m
(5 '-6
EQEQ
m m
(5 '-6
Message Layout A Message Layout B Message Layout C
12/2012 Page 4-7-62
Exterior SignsEN-14 Building Entrance Door Identification
Message Layout AMessage Layout AMessage Layout A Message Layout B Message Layout C
12/2012
Mandatory Policy Signs
IN-02.01
Consent to Inspection
Size Sign Face:
152 mm H x 508 mm W
(6" H x 20" W)
Description "Consent to Inspection" sign is required to be placed at the entrance of a building.
Message Configuration (Refer to message layout drawing for dimensions).
Sign Components Acrylic plaque
Graphic Process Silk-screened
Introduction of weapons, unauthorized drugs and alcoholic beverages on this property is prohibited (title 18 USC Section 930 and title 38 CFR Section 1.218). Persons entering this property consent to an inspection of all packages, luggage and containers in their possession when arriving. Refusal of consent to search is basis for denial of admittance. Violators are subject to arrest and prosecution. Refusal of consent to an authorized search by medical personnel is basis for discharge.
Colors For background and type colors, refer to VA color chart.
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive
Installation Sign can be coordinated to be placed with other policy signs, IN
02.2 and IN-02.3 that are required at the entrance.
Introduction of weapons, unauthorized drugs and alcoholic beverages on this property is prohibited (title 18 USC Section and title 38 CFR Section 1.218). Persons entering this property consent to an inspection of all packages, luggage and containers in their possession when arriving. Refusal of consent to search is basis for denial of admittance. Violators are subject to arrest and prosecution. Refusal of consent to an authorized search by medical personnel is basis for discharge.
m m
(5 '-7
IN
-0
2.
Page 7-4-1 http:IN-02.01
12/2012 Page 7-4-2
Consent to Inspection
A lig n 25 mm (3/8”) 5 mm (3/16”)
152 mm (6”)
3 mm (1/8”)
22 mm (7/8”)
38 mm (1-1/2”)
508 mm (20”)
IN-02.01 Exhibit X
12/2012 Page 7-4-3
Size Sign Face:
152 mm H x 508 mm W (6" H x 20" W)
Description "No Smoking" sign is required to be placed at the entrance of a building.
Message Configuration (Refer to message layout drawing for dimensions).
Sign Components Acrylic plaque
Graphic Process Silk-screened
Colors For background and type colors, refer to VA color chart.
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive
Installation Sign can be coordinated to be placed with other policy signs, IN-02.01 and IN-02.03 that are required at the entrance.
No Smoking
IN-02.02
| No | Smoking | |||||||
| For | the | sake | of | your | health | & | comfort | of |
| others, | smoking | is | prohibited | in | this | |||
| Medical | Center. | If | you | must | smoke, | |||
| please | do | so | only | in | designated | areas. |
| No | Smoking | |||||||
| For | the | sake | of | your | health | & | comfort | of |
| others, | smoking | is | prohibited | in | this | |||
| Medical | Center. | If | you | must | smoke, | |||
| please | do | so | only | in | designated | areas. |
m m
(5 '-7
IN
-0
2.
12/2012 Page 7-4-4
No Smoking
A lig n 30 mm (1-3/16”)
19 mm (3/4”)
73 mm (2 - 7/8”)
13 mm (1/2”)
13 mm (1/2”) 5 mm (3/16”)
5 mm (3/16”)
152 mm (6”)
3 mm (1/8”)
16 mm (5/8”)
38 mm (1-1/2”)
508 mm (20”)
IN-02.02 Exhibit X
12/2012 Page 7-4-5
Size Sign Face:
152 mm H x 508 mm W (6" H x 20" W)
Description "No Weapons" sign is required to be placed at the entrance of a building.
Message Configuration (Refer to message layout drawing for dimensions).
Sign Components Acrylic Plaque
Graphic Process Silk-screened
Colors For background and type colors, refer to VA color chart.
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive
Installation Sign can be coordinated to be placed with other policy signs, IN-02.01 and IN-02.02 that are required at the entrance.
No Weapons Permitted
IN-02.03
| Whoever | knowingly | possesses | or | causes | the | presence | of | a | firearm | ||||
| or | other | dangerous | weapon | on | the | grounds | or | buildings | of | this | |||
| facility, | or | attempts | to | do | so, | is | subject | to | fine | or | imprisonment | of | |
| not | more | than | one | year, | or | both. | 18 | U.S.C. | Section | 930a. | Whoever | ||
| intends | that | a | firearm | or | other | dangerous | weapon | be | used | in | the | ||
| commission | of | a | crime | and | knowingly | possesses | or | causes | the | ||||
| presence | of | a | firearm | or | other | dangerous | weapon | on | the | grounds | or | ||
| buildings | of | this | facility, | or | attempts | to | do | so, | is | subject | to | fine | or |
| imprisonment | of | not | more | than | five | years, | or | both. | 18 | U.S.C. | Section |
930b.
| Whoever | knowingly | possesses | or | causes | the | presence | of | a | firearm | ||||
| or | other | dangerous | weapon | on | the | grounds | or | buildings | of | this | |||
| facility, | or | attempts | to | do | so, | is | subject | to | fine | or | imprisonment | of | |
| not | more | than | one | year, | or | both. | 18 | U.S.C. | Section | 930a. | Whoever | ||
| intends | that | a | firearm | or | other | dangerous | weapon | be | used | in | the | ||
| commission | of | a | crime | and | knowingly | possesses | or | causes | the | ||||
| presence | of | a | firearm | or | other | dangerous | weapon | on | the | grounds | or | ||
| buildings | of | this | facility, | or | attempts | to | do | so, | is | subject | to | fine | or |
| imprisonment | of | not | more | than | five | years, | or | both. | 18 | U.S.C. | Section |
930b.
m m
(5 '-7
IN
-0
2.
12/2012 Page 7-4-6
No Weapons Permitted
A lig n
25 mm (3/8”) 3 mm (1/8”)
152 mm (6”)
3 mm (1/8”)
16 mm (5/8”)
38 mm (1-1/2”)
508 mm (20”)
IN-02.03 Exhibit X
12/2012 Page 7-4-11
Single Post Parking Notice
Size Sign Face:
762 mm H x 610 mm W (30" H x 24" W)
Description Large, non-illuminated single post or wall mounted tow away informational sign.
Sign is similar to sign type EN-
05.01. See exterior sign section for
construction and installation details.
Message Configuration (Refer to message layout drawing for dimensions).
Graphic Process Surface applied reflective vinyl
Colors Text: white Background: refer to color chart.
Post: refer to color chart.
Installation It is recommended that this sign be placed at the entrance drive to the VA site.
Position sign so drivers have a clear, unobstructed view of the sign.
When placing this type of sign near curbs or parking places, be sure the sign is set far enough back that over hanging front and rear of automobiles do not come in contact with the sign post.
Message Layout
Single Post Option Wall Mounted Option
NOTICE
Parking restrictions are enforced daily by VA Police.
Violators are subject to citation and tow at owner’s expense.
(38 CFR Section 1.218)
NOTICE
Parking restrictions are enforced daily by VA Police.
Violators are subject to citation and tow at owner�s expense.
(38 CFR Section 1.218)
NOTICE
Parking restrictions are enforced daily by VA Police.
Violators are subject to citation and tow at owner’s expense.
(38 CFR Section 1.218)
IN-02.06 Exhibit X
12/2012 Page 7-4-12
Parking Notice Sign: Single Post and Wall Mounted options
A lig n
38 mm (1 - 1/2”)
76 mm (3”)
76 mm (3”)
610 mm (2’ - 0”)
25 mm (1”)
76 mm (3”)
35 mm (1-3/8”)
35 mm (1-3/8”)
762 mm (2’ - 6”)
73 mm (2 - 7/8”)
168 mm (3 - 5/8”)
1779 mm (5’ - 10”)
3 mm (1/8”)
1779 mm (5’ - 10”)
Sign Panel Mounted to Wall with Adhesive
IN-02.06 Exhibit X
12/2012 Page 7-4-17
Size 152 mm H x 508 mm W (6" H x 20" W )
Description "No Weapons" sign to be placed at all public building entrances.
Message Configuration Refer to message layout drawing for dimensions.
Sign Components Acrylic plaque
Graphic Process Silk-screened
Colors Background: white Graphics: red, white, blue, and black
Typography Helvetica Medium Condensed:
Regular Condensed
Mounting Double sided foam tape or silastic adhesive.
Installation On wall, 1676 mm (66") to top of top sign. When placed adjacent to door, sign should be mounted on hinged side of door.
No Weapons Sign: Small m m
(5 '-6 m m
(5 '-6 m m
(5 '-6
English Version
Spanish Version
IN-02.10 Exhibit X
12/2012 Page 7-4-18
No Weapons Sign: Small
1 1/2" (38 mm)
1" (25 mm)
1" (25 mm)
6" (152 mm)
3/4" (19 mm)
4" (101 mm)
20" (508 mm)
IN-02.10 Exhibit X
12/2012 Page 7-4-19
No Weapons Sign: large
Size 762 mm H x 610 mm W (30" H x 24" W )
Description Non-illuminated wall mounted or single post “No Weapons” sign.
To be placed at all public drive entrances to site.
Message Configuration Refer to message layout drawing for dimensions.
Sign Components Aluminum sign panel
Graphic Process Silk-screened or surface applied vinyl
Colors Background: white Graphics: red, white, blue, and black
Typography Helvetica Medium Helvetica Regular Italic
Installation It is recommended that this sign be placed at all public drive entrances to site.
Position signs so drivers have a clear, unobstructed view of the sign.
When placing this type of sign near curbs or parking places, be sure the sign is set far enough back that over hanging front and rear of automobiles do not come in contact with the sign post.
Single Post Option Wall Mounted Option
Message Layout: English Version Message Layout: Spanish Version
IN-02.11 Exhibit X
12/2012 Page 7-4-20
No Weapons Sign: large
IN-02.11 Exhibit X
12/2012 Page 7-4-21
Security Notice Sign
Size Sign Face:
610 mm H x 457 mm W (24" H x 18" W)
Description Large, non-illuminated single post or informational sign
Sign is similar to sign type EN-05.01. See exterior sign section for construction and installation details.
Message Configuration Refer to message layout drawing for dimensions.
Graphic Process Surface applied vinyl
Colors Text: white Background: refer to color chart.
Post: refer to color chart.
Installation It is recommended that this sign be placed at hospital entrances, exits, and building ventilation intakes.
Message Layout
Single Post Option
IN-02.12 Exhibit X
12/2012 Page 7-4-22
Security Notice Sign
IN-02.12 Exhibit X
12/2012 Page 8-5-1
Code and Life Safety Signs
Sign 508 mm H x 508 mm W (20" H x 20" W)
Description and Use NOTE: This sign type is optional except for hoptels when they are considered a hotel/dormitory type occupancy.
Evacuation Map/Fire Exit Plan with pocket to accept map insert is to be placed at points of exit and transition in a building (all elevators, exits, and exiting stairwell doors);
other locations as needed. Use this large size sign when large size maps are necessary.
Evacuation maps can be created by the medical center and inserted into the sign in accord with the facilities evacuation plan. The map must be oriented relative to the specific location of the sign i.e., (what is to the right on the drawing should be to the right of the viewer). Refer to the You Are Here section (Section 10) for additional information regarding maps.
Local fire departments may request these signs be installed.
If requested, coordinate locations with their requirements.
Message Configuration Refer to layout drawing for lettering sizes and dimensions.
Sign Components Face: clear 1.5 mm (1/16") non-glare acrylic with subsurface background color creating a clear window.
Spacer to receive a clear 0.4 mm (1/64") insert. Backing plaque:
surface painted 6 mm (1/4") acrylic.
Graphic Process Sign: silk-screened. Insert: printed
Colors Type: refer to color chart.
Background: refer to color chart.
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive.
Installation On wall, 1600 mm (63") to top of sign emergency exit Plan
Fire & Emergency Exit Plan Warning: Do not use elevators in case of fire or other electrical emergencies. Use marked exits.
IN-01.01.1
20" H x 20" W 11" x 17" Insert
11/17/03 m m
(5 '-3
Insert
IN-01.01.01
m m
(5 '-3
12/2012 Page 8-5-2 emergency exit Plan
IN-01.01.01
m m
(5 '-3
12/2012 Page 8-5-5
Fire equipment Identification Sign
IN-01.02
Sign 229 mm H x 229 mm W (9" H x 9" W)
Description and Use Fire equipment identification sign is used to locate and identify fire equipment cabinets.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions).
Sign Components Acrylic plaque
Graphic Process Silk-screened
Colors Text and symbol: white Background: red
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive
Installation On wall, 1829 mm (72") to top of sign, perpindicular to wall: 2032 mm (80") clear above floor.
NOTE
Code requirements for identifying fire equipment state this sign is to be mounted above the fire equipment cabinet, flat against the wall. An alternate option for displaying this sign is to mount it in the same location, but perpendicular to the wall centered above the cabinent. Refer to sign type IN–01.31 for perpendicular/ blade mounted option.
Fire Equipment m m (6
'-0
FIRE
EQUIPMENT
CABINET
m m
(6 '-0
FIRE
EQUIPMENT
CABINET
12/2012 Page 8-5-6
Fire equipment Identification Sign
IN-01.02
m m
(6 '-0
FIRE
EQUIPMENT
CABINET
12/2012 Page 8-5-11
Fire Door Sign
IN-01.05
Sign 229 mm H x 229 mm W (9" H x 9" W)
Description and Use Fire Door sign is used to identify a fire door. Exception: signs shall not be provided for fire doors that are held open by automatic devices.
This sign is optional and not required by the Life Safety Code.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions).
Sign Components Acrylic plaque
Graphic Process Silk-screened
Colors Text: white Background: red
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive
Installation Centered on door, 1600 mm (63") to top of sign.
Keep closed at all times.
Fire Door
CL
m m
(5 '-3
CL
m m
(5 '-3
12/2012 Page 8-5-12
Fire Door Sign
IN-01.05
CL
m m
(5 '-3
12/2012 Page 8-5-13 no exit Sign
IN-01.06
Sign 229 mm H x 229 mm W (9" H x 9" W)
Description and Use No Exit sign used to identify a door in a stairwell or other locations that are not exits.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions). Letters in "NO" must be 2" high and 3/8" stroke width; letters in "EXIT" must be 1" high and below "NO" per
NFPA 101.
Sign Components Acrylic plaque
Graphic Process Silk-screened
Colors Text: refer to color chart.
Background: refer to color chart.
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive
Installation Centered on door, 1600 mm (63") to top of sign.
NO
EXIT
CL
m m
(5 '-3
CL
m m
(5 '-3
12/2012 Page 8-5-14 no exit Sign
IN-01.06
CLCL
m m
(5 '-3
12/2012 Page 8-5-15 exit Sign
IN-01.07
Size
IN-01.07.01
229 mm x 559 mm (9" x 22")
IN-01.07.02
229 mm x 559 mm (9" x 22")
IN-01.07.03
229 mm x 559 mm (9" x 22")
IN0-1.07.04
229 mm x 712 mm (9" x 28")
Description and Use Non-illuminated exit sign used to identify exit or direction to exit.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions). Letters must be no less than 6" in height per NFPA 101. Principal stroke of letters must be no less than 3/4" wide. Each letter must have a width of no less than 2" except the letter “I”. Minimum spacing between letters must be no less than 3/8".
Sign Components Acrylic plaque
Graphic Process Silk-screened
Colors Text: refer to color chart.
Background: refer to color chart.
Typography Helvetica Medium Condensed
Mounting Double sided foam tape or silastic adhesive
Installation Center on soffit area directly above door frame.
EXIT
EXIT
EXIT
CL
EQ20
m m
(6 '-8 m ax
EXIT
IN-01.07.01 IN-01.07.02
IN-01.07.03 IN-01.07.04
EXIT
EXIT
CL
EQ
m m (6
'-8 m ax
EXIT
12/2012 Page 8-5-16 exit Sign
IN-01.07
IN01.07.01
IN01.07.02
IN01.07.03
IN01.07.04
CL
EQ
12/2012 Page 8-5-45
Code and Life Safety SignsIN-01.22 Biohazard Warning Sign
Size 229 mm H x 229 mm W (9" H x 9" W)
Description and Use Caution information regarding biohazard materials. Sign must be installed on the doors of all rooms where there is biohazard materials.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions).
Sign Components Acrylic plaque
Graphic Process Silk-screened
Colors Text and symbol: black Background: orange
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive
Installation Centered on door, 1600 mm (63") to top of sign
CAUTION
Biohazard
CL
m m
(5 '-3
CL
m m
(5 '-3
12/2012 Page 8-5-46
Biohazard Warning Sign
IN-01.22
CL
m m
(5 '-3
12/2012 Page 8-5-63
Code and Life Safety SignsIN-01.31 Fire equipment Identification Sign
Sign Size 229 mm H x 229 mm W (9" H x 9" W)
Description and Use Fire equipment identification sign is a flag sign used to identify a fire equipment cabinet.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions).
Sign Components Acrylic plaque with aluminum bracket for flag mounting
Graphic Process Silk-screened
Colors Text and symbol: white Background: red Bracket: aluminum
Typography Helvetica Bold
Mounting Mechanical fasteners with anchors
Installation Centered above fire equipment cabinet a 2129 mm (7'-0") to bottom of sign; mechanically fastened to wall with expandable anchors as needed for wall type.
NOTE
Code requires that signage identifying fire equipment needs to be mounted above the fire equipment cabinet, flat against the wall. This perpendicular / blade mounted variation is an alternate option for displaying this information. Refer to sign type IN–01.02 for a wall mounted version of this sign.
Side A Side B
Fire Equipment Fire Equipment m m (7
'-0
M
IN
FIRE
EQUIPMENT
CABINET
Fire Equipment m m
(7 '-0
M
IN
FIRE
EQUIPMENT
CABINET
12/2012 Page 8-5-64
Fire equipment Identification Sign
IN-01.31
CL
127 mm (5”)
229 mm (9”)
19 mm (3/4”)
20 mm (13/16”)
30 mm (1-3/16”)
229 mm (9”) 51 mm (2”) m m (7
'-0
M
IN
FIRE
EQUIPMENT
CABINET
m m
(7 '-0
M
IN
FIRE
EQUIPMENT
CABINET
12/2012 Page 9-5-1
Interior Signs Room Number Identification
IN-03.01
Size 76 mm H x 229 mm W (3" H x 9" W)
Description and Use Sign is to be used to identify rooms
Message Configuration (Refer to layout drawing for lettering sizes and dimensions)
Sign Components Varies by sign family component sign system, rails, curved and flat frames.
Graphic Process Tactile room number with accompanying Braille.
Colors Text: refer to color chart.
Background: refer to color chart
Typography Helvetica Grade 2 Braille
Mounting Double sided foam tape, silastic adhesive or screw.
Installation Knob side of door, 1524 mm (60") to top of sign and 50 mm (2") over from door frame.
Recommendations This sign is to be used for all rooms, but can also be used to identify corridors and alcoves as necessary. Do not use on exterior and stairwell doors.
Message Layout A
50 mm (2") m m
(5 '-0
2528625286
2528625286
2528625286
2528625286
12/2012 Page 9-5-2
Room Number Identification
IN-03.01
Raised Letters
Braille
End View
A-2578
1 1/4” height
1/8” Min Letter Spacing
Copy Helvetica Medium raised tactile text
Braille Grade 2 Domed
3/8” Min clear space
3/8” Min. clear space
3/8” Min. clear space
Approx 1/4”
3/8” Min clear space 3/8” Min clear space
B aseline Spacing
Front View
1/2”
Braille
3/8"
3/4"
229 mm (9”)
3"
1/2"
1 1/4"
3/8" 1/4"
25286
50 mm (2") m m
(5 '-0
12/2012 Page 9-5-3
Primary Room Identification
IN-04.01
25286
Message Layout A
Message Layout D
Message Layout B
50 mm (2") m m
(5 '-0
Outpatient Pharmacy
44444 44444
Oncology Diagnostic Imaging Clinic
44444
Laboratory
C
25286 25286
Outpatient Conference Room
44444
44444
Outpatient Pharmacy
44444 4444444444
44444444444444444444
Message Layout C
Size 229 mm H x 229 mm W (9" H x 9" W)
Description and Use This sign has tactile number and Braille on the top sign component.
The sign is to identify the occupant or activity within a room.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions) Layout A is suggested for department identification. Layout B for rooms and departments with long words or names. Layout C for rooms with a common name but need specific identification.
Sign Components Vary by sign family, sliding rail component systems, curved and flat. Top section raised text and Braille. Lower section can be digital print, ,silkscreen or vinyl applied graphics.
Graphic Process Tactile raised text and Braille on top section. Surface applied vinyl or insert in lower sign section.
Colors Text: refer to color chart.
Background: refer to color chart
Typography Helvetica Bold Grade 2 Braille
Mounting Double sided foam tape, silastic adhesive or screw.
Installation Knob side of door, 1524 mm (60") to top of sign and 50 mm (2") over from door frame.
Recommendations It is recommended that this particular sign type become the "building standard" for identification of all rooms.
Signs identifying electrical closets, mechanical rooms and telecommunication rooms should consist of only the room number (Sign type IN-03.01). The room number should follow the master building room numbering system. No descriptive name or title should be used nor should they have a unique number system.
12/2012 Page 9-5-4
Primary Room Identification
IN-04.01
Message Layout C
Message Layout A & B
Message Layout D
50 mm (2") m m
(5 '-0
12/2012 Page 9-5-19
Room Sign with Indicator
IN-07.01-.03
IN-07.01
(Message Layout A)
IN-07.01
(Message Layout B)
IN-07.02 IN-07.03
50 mm (2") m m
(5 '-0
Outpatient Conference Room
In Use
In Use
Exam A
25286 25286
25286 25286
Outpatient Conference Room
In Use
25286 25286
In Use
25286 25286
Exam
A
Conference Room
In Use
25286 25286
Size / Sign Size
IN-07.01
229 mm x 229 mm (9" H x 9" W)
IN-07.02
152 mm x 229 mm (6" H x 9" W))
IN-07.03
203 mm x 229 mm (8" H x 9" W)
Description and Use This sign always has tactile and Braille section at the top of the sign component. Use this sign for conference rooms, meeting rooms.
This type of sign can also be used for exam rooms, treatment rooms, and offices where the occupants want to indicate that room is in use.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions) IN07.1, Layout A is for conference rooms, Layout B is for exam or treatment rooms. N07.3 Insert messages are prepared and removed based upon occupancy of the room. Selection of the text to appear behind the slider is to be determined by the sign users.
Sign Components Vary by sign family, sliding rail component systems, curved and flat. Top section raised text and Braille. Mid section can be digital print or vinyl applied graphics.
Lower section moving slider with graphic reveal.
Graphic Process Slider section surface applied vinyl. Text behind slider is second surface.
Colors Text: refer to color chart.
Background: refer to color chart
Typography Helvetica Bold Grade 2 Braille
Mounting Double sided foam tape, silastic adhesive or screw.
Installation Knob side of door, 1524 mm (60") to top of sign and 50 mm (2") over from door frame.
Recommendations This sign is for use on rooms where and indication is needed in the hallway that the room is occupied or an activity is taking place in the room which should not be disturbed.
12/2012 Page 9-5-20
Interior SignsIN-07.01-.03 Room Sign with Indicator
50 mm (2") m m
(5 '-0
IN-07.01 (Message Layout A)
IN-07.01 (Message Layout B)
IN-07.02
IN-07.03
12/2012 Page 9-5-25
Size 229 mm H x 229 mm W (9" H x 9" W)
Description and Use Use these signs to inform in a bold manner.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions)
Sign Components Acrylic plaque.
Graphic Process Silk-screened or surface applied vinyl.
Colors Text: Black Symbol: Red and Black Background:
White
Typography Helvetica Bold Helvetica Bold Condensed
Mounting Double sided foam tape or silastic adhesive.
Installation On wall or door 1600 mm (63") to top of sign and on door, center.
Recommendations This sign is for use when a strong communication of information is necessary. IN08.4 should be used carefully as it may have a negative reaction on the part of patients and visitors.
Prohibit Instructional and Control
IN-08.02
Message Layout BMessage Layout A
Message Layout C
Staff Only
CL
m m
(5 '-3 m m
(5 '-3
Message Layout D
Authorized Personnel
Only
No Admittance
No Admittance
12/2012 Page 9-5-26
Prohibit, Instructional and Control
IN-08.02
Message Layout D
Message Layout A
28.5 mm (1 1/8")
165 mm (6 1/2")
Message Layout C
16mm 5/8”
19mm 3/4”
16mm 5/8” 19mm 3/4”
101mm 4”
CL
m m
(5 '-3 m m
(5 '-3
Message Layout B
19 mm 3/4”
101mm (4”)
16mm 5/8“” 16mm 5/8” 9mm 3/8”
12/2012 Page 9-5-27
Restroom Identification
IN-09.01-.06
Size 311 mm H x 229 mm W (12 1/4" H x 9" W)
Description and Use Use these signs to inform with a symbol, tactile raised text and Braille.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions)
Sign Components Vary by sign family, component systems, curved and flat. Top section raised text and Braille.
Lower section to be raised graphic symbol.
Graphic Process Tactile symbol and text with accompanying Braille.
Colors Text: refer to color chart.
Background: refer to color chart
Typography Helvetica Bold Grade 2 Braille
Mounting Double sided foam tape or silastic adhesive.
Installation On wall or door 1524 mm (60") to top of sign and on door, center.
Recommendations These signs are for use to identify restrooms.
m m
(6
50 mm (2")
Wall mounted
RESTROOM
24244 2A244
MEN
24244 2A244
WOMEN
24244 2A244
IN-09.06
RESTROOM
24244 2A244
IN-09.03IN-09.01 IN-09.02
MEN
24244 2A244
WOMEN
24244 2A244
IN-09.04 IN-09.05
MEN
24244 2A244
12/2012 Page 9-5-28
Restroom Identification
IN-09.01-.06
152.4 mm
6” Icon Area
235 mm (9-1/4”)
25 mm (1”) m m
(6 0"
50 mm (2")
Symbol
Braille
12/2012 Page 9-5-37
Perpendicular (Flag) Mount
IN-13
Message Layout B
Message Layout C
This Way Out
This Way Out
Side B
Side A Side B m m
(7 '-0
M
IN
Cardiac Intervention
Unit
Cardiac Intervention
Unit
Cardiac Intervention Unit
Side A
Side A Side B
Message Layout A
RestroomsRestrooms
Size 229 mm H x 305 mm W (9" H x 12" W)
Description and Use Use this sign for messages to be communicated in corridors on the wall, above doors.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions) Layout A is for symbols and title / informational text. Layout B is for directional information. Layout C is for a department name.
Sign Components Sliding rail component systems, Curved and flat inserts vinyl applied graphics.
Graphic Process Surface applied vinyl.
Colors Text and Symbols: Refer to color chart.
Background: refer to color chart Base: refer to color chart
Typography Helvetica Bold Condensed
Mounting Wall mount with screws.
Installation Install on wall above the height of doors, 2134 mm (84") minimum to bottom of sign.
Recommendations This sign is for use when the service or department is a high traffic area or the service or department door is hard to find.
12/2012 Page 9-5-38
Perpendicular (Flag) Mount
IN-13
m m
(7 '-0
M
IN
Message Layout A
Message Layout B
Message Layout C
12/2012 Page 9-5-51
Ceiling Mounted Directional and Identification
IN-15.51
Size
IN-15.51A
152 mm x 1016 mm (6" x 40") 3" and 2" text with directional arrows
Description and Use Use this sign for directional and department identification information that needs to be communicated overhead. Sign is double sided and both sides can be used for messages.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions).
Sign Components Vary by sign family. Sliding rail component systems, curved and flat panels with vinyl applied graphics.
Graphic Process Surface applied vinyl or digital print.
Colors Text and arrows: refer to color chart.
Background: refer to color chart.
Typography Helvetica Bold Helvetica Bold Condensed 76 mm (3") and 51 mm (2") cap height text.
Mounting Ceiling hung 2134 mm (7'-0") from floor.
Installation From the ceiling. Braided stainless steel wire or rod. Sign must not be attached directly to "T Grid" or lift out ceiling tile.
Recommendations This sign is for use in corridors to direct patients and public through the building. Because of required letter height, there is a limit to the length of messages and a limit to number of messages.
Verify that ceiling height will accommodate sign height.
Clearance requirement is 2134 mm (84").
Message Layout B (Department I.D.)
EMERGENCY
Canteen Message Layout A (Directional with Arrows)
EQ. EQ.
m m
(7 '-0
M
IN
EQ EQ
Message Layout C
Outpatient Services
Sign Type Layout Width Height Size Family
IN-15.51 A 40" 6" 3" All x IN-15.51 B 40" 6" 3" All x IN-15.51 C 40" 6" 2" All x x
Text Sign Department
ID
Directional
Arrows
12/2012 Page 9-5-52
Ceiling Mounted Directional and Identification
IN-15.51
Message Layout A
Message Layout B
Message Layout C
EQ. EQ.
m m
(7 '-0
M
IN
EQ EQ
12/2012 Page 9-5-75
Soffit Mounted Directional and Identification
IN-16.51
Registration
EQ. EQ.
EQ EQ
Outpatient Pharmacy
Surgery
Sign Type Layout Width Height Size Family
IN-16.51 A 40" 6" 3" All x IN-16.51 B 40" 6" 3" All x IN-16.51 C 40" 6" 2" All x x
Text Sign Department
ID
Directional
Arrows
Message Layout B (Department I.D.)
Message Layout A (Directional with Arrows)
Message Layout C
Size
IN-16.51
152 mm x 1016 mm (6" x 40") 3" and 2" text with and without directional arrows
Description and Use Use this sign for directional and department identification information that needs to be communicated overhead. Sign is single sided mounted on wall or over doorway.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions)
Sign Components Vary by sign family. Sliding rail component systems, curved and flat panels with vinyl applied graphics.
Graphic Process Surface applied vinyl
Colors Text and arrows: refer to color chart.
Background: refer to color chart
Typography Helvetica Bold Helvetica Bold Condensed 76 mm (3") and 51 mm (2") cap height.
Installation Secure to wall with physical fasteners
Recommendations This sign is for use in corridors to direct patients and public through the building. Because of required letter height there is a limit to the length of messages and a limit to the number of messages.
12/2012 Page 9-5-76
Soffit Mounted Directional and Identification
IN-16.51
Message Layout A
Message Layout B
Message Layout C
EQ. EQ.
EQ EQ
12/2012 Page 9-5-103
Dimensional Letters
IN-19.01-.03
Size
IN-19.01
76 mm H x 10 mm D (3" H x 3/8" D)
IN-19.02
102 mm H x 10 mm D (4" H x 3/8" D)
IN-19.03
152 mm H x 10 mm D (6" H x 3/8" D)
Description and Use Identification of information counters, major departments or services.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions).
Sign Components Painted acrylic
Graphic Process Cut out acrylic dimensional letters.
Colors Text: refer to color chart Color should have a high contrast with surrounding wall color and surface.
Typography Helvetica Bold
Mounting Silastic adhesive and studs.
Installation On walls or soffits.
Recommendations Dimensional letters provide high impact, high visibility and formal identification. Do not use for departments or services that have frequent relocation’s or name changes. Suggested typical uses would be for Information, Check In, Canteen, Pharmacy, etc.
m m
M
IN
IM
U
M (5
'-0
Admitting
Pharmacy
Medi
EQ
m m (3
EQ
12/2012 Page 9-5-104
Dimensional Letters
IN-19.01-.03
IN-19.01
IN-19.02
IN-19.03
12/2012 Page 9-5-105
Instructional Sign
IN-20.01
Size 152 mm x 152 mm (6" H x 6" W)
Description and Use Use this sign above handicap accessible automatic door opening buttons.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions)
Sign Components Painted acrylic
Graphic Process Silk-screened or surface applied vinyl.
Colors Text: Refer to color chart Background: Refer to color chart
Typography Helvetica Bold
Mounting Double sided foam tape or silastic adhesive.
Installation On wall 6" above automatic door opening button.
Recommendations These signs help bring attention and provide direction to doors with automatic opening capability.
152 mm (6)"
CL
Push Button to Open Door
PUSH
BUTTON TO
OPEN DOOR
Push Button to Open Door
12/2012 Page 9-5-106
Instructional Sign
IN-20.01
3.2 mm (1/8”)
A lig n
13 mm (1/2”)
152 mm (6”)
25 mm (1”)
16 mm (5/8”)
16 mm (5/8”)
16 mm (5/8”)
13 mm (1/2”)
13 mm (1/2”) 152 mm (6”)
12/2012 Page 9-5-25
Size 229 mm H x 229 mm W (9" H x 9" W)
Description and Use Use these signs to inform in a bold manner.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions)
Sign Components Acrylic plaque.
Graphic Process Silk-screened or surface applied vinyl.
Colors Text: Black Symbol: Red and Black Background:
White
Typography Helvetica Bold Helvetica Bold Condensed
Mounting Double sided foam tape or silastic adhesive.
Installation On wall or door 1600 mm (63") to top of sign and on door, center.
Recommendations This sign is for use when a strong communication of information is necessary. IN08.4 should be used carefully as it may have a negative reaction on the part of patients and visitors.
Prohibit Instructional and Control
IN-08.02
Message Layout BMessage Layout A
Message Layout C
Staff Only
CL
m m
(5 '-3 m m
(5 '-3
Message Layout D
Authorized Personnel
Only
No Admittance
No Admittance
12/2012 Page 9-5-26
Prohibit, Instructional and Control
IN-08.02
Message Layout D
Message Layout A
28.5 mm (1 1/8")
165 mm (6 1/2")
Message Layout C
16mm 5/8”
19mm 3/4”
16mm 5/8” 19mm 3/4”
101mm 4”
CL
m m
(5 '-3 m m
(5 '-3
Message Layout B
19 mm 3/4”
101mm (4”)
16mm 5/8“” 16mm 5/8” 9mm 3/8”
12/2012 Page 9-5-7
Primary Room Identification with Insert
IN-04.03
Size 229 mm H x 229 mm W (9" H x 9" W)
Description and Use This sign always has tactile number and Braille as its top sign component. Lower section is for insert. Use this sign to identify the occupant or activity within a room.
Message Configuration (Refer to layout drawing for lettering sizes and dimensions) Layout A is suggested for department identification. Layout B for rooms and departments with long words or names. Layout C and D for rooms with a common name but need specific identification.
Sign Components Vary by sign family, sliding rail component systems, curved and flat.
Top section raised text and Braille.
Lower section can be inserted graphics.
Graphic Process Tactile raised text and Braille on top section. Insert with clear protector cover with surface applied vinyl on substrate or paper printed insert in lower sign section.
Colors Text: refer to color chart.
Background: refer to color chart
Typography Helvetica Bold Grade 2 Braille Lettering size is adaptable to allow messages to fit on to the sign. Refer to various layouts for reference.
Mounting Double sided foam tape, silastic adhesive or screw.
Installation Knob side of door, 1524 mm (60") to top of sign and 50 mm (2") over from door frame.
Recommendations It is recommended that this particular sign type become the "building standard" for identification of all rooms.
Signs identifying electrical closets, mechanical rooms and telecommunication rooms should consist of only the room number (Sign type IN-03.01). The room number should follow the master building room numbering system. No descriptive name or title should be used nor should they have a unique number system.
25286
Message Layout A
Message Layout D
Message Layout B
50 mm…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .