Attachment 2. LimitedSourceJustification Backflow - Redacted.pdf

PDF 188 KB Posted

Attached to
J045--Backflow Preventer Erie VAMC Federal contract opportunity
Solicitation number
36C24420Q1114
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

View the file

Other files for this federal contract opportunity

Other files attached to J045--Backflow Preventer Erie VAMC, newest first.
File Type Posted
36C24420Q1114 0003_1.docx DOCX document
36C24420Q1114 0002_1.docx DOCX document
Attachment 1. Questions_Answers Q1114 - 2.docx DOCX document
36C24420Q1114 0001_1.docx DOCX document
Attachment 1. Questions_Answers Q1114.docx DOCX document
Attachment C. VA Privacy Training.pdf PDF
Attachment B. EPA Cross Connection Control Manual Ch 5.pdf PDF
Attachment D. Internal Inspection.pdf PDF
36C24420Q1114_1.docx DOCX document
Attachment 1. WD 2015-4223 Erie County REV 13 dated 5-1-2020.pdf PDF
Attachment A. Inventory List.pdf PDF
36C24420Q1114 Combined Synopsis - Backflow Preventers.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT

VHAPM Part 813.106 Page 1 of 2 Original Date: 08/30/17 Revision 02 Eff Date: 03/31/2020

DEPARTMENT OF VETERANS AFFAIRS

Justification for Single Source Awards IAW FAR 13.106-1 For

Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)

Acquisition Plan Action ID:

PR#:

1. Contracting Activity: Department of Veterans Affairs, Services Area Office East (SAO-E), Network Contracting Office 4 (NCO4) provides contracting support for DVA, Veterans Integrated Services Network 4 (VISN4), Erie VA Medical Center (VAMC).

2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:

Erie VAMC has a need for annual testing and maintenance of back flow devices and the rebuilding of two backflow devices. This request is for a brand name of Erie Water Works Licensed Backflow Tester.

Estimated price is

3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:

The Erie Water Works Cross-Connection Control Program was established in 1974 as mandated by the Safe Drinking Water Act (SDWA). According to the city’s Official Ordinance No 86-1974, Article 936.05: all testing and maintenance will be conducted by a certified backflow prevention device tester. According to the city’s Cross Connection Control Termination Policy, the testing must be completed by an Erie Water Works Licensed Tester (EWW). The city provides a list of requirements to becoming a licensed backflow tester within the city’s water work system. The city also provides a list of licensed plumbers who are EWW Licensed Backflow Testers. This requirement is specific and unique to the city of Erie.

4. Description of market research conducted and results or statement why it was not conducted:

The required license is specific to Erie. A list provided by the EWW of Licensed Back flow testers showed 30 vendors approved to perform the work. A VIP search was conducted by name and none of the 30 vendors were in VIP. A search by name was conducted in Beta Sam, 2-SB and 4-Large were registered in SAM.