36C24225B0019 0004.pdf

PDF 619 KB Posted

Attached to
Z1DA--NRM-CONST 528A7-18-740 REPLACE 7C PATIENT DOORS AND SINKS Federal contract opportunity
Solicitation number
36C24225B0019
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2

About this file

This document is a Standard Form 30 Amendment of Solicitation/Modification of Contract for the Department of Veterans Affairs, relating to a project to replace 7C Patient Room Doors and Sinks (Solicitation Number 36C24225B0019). The amendment includes Requests for Information (RFIs) and responses addressing several key technical details for potential bidders, including:

The RFIs cover specific technical clarifications such as Vistamatic glass specifications (not ballistic glass), missing drawing GC-101 for ICRA Barrier, fire barrier requirements, wall type details, and requests for plumbing prints showing in-wall piping diagrams. Responses indicate updated drawings (REV 4) will be provided, specifying details like using Type 6B wall with high-impact resistant gypsum wallboard, and promising additional plumbing floor prints to help contractors accurately determine material and labor quantities for the project.

View the file

Other files for this federal contract opportunity

Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE 7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO. 1. CONTRACT ID CODE

FACILITY CODE CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30 PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243

(Type or print) (Type or print)

(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code)

(If other than Item 6)

(Specify type of modification and authority)

(such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer)

528A7-18-740

Department of Veterans Affairs Network Contracting Office 02 1304 Buckley Road Suite 101 Syracuse NY 13212

Department of Veterans Affairs Network Contracting Office 02 1304 Buckley Road Suite 101 Syracuse NY 13212

To all Offerors/Bidders

36C24225B0019

X

X X x

RFI QUESTIONS AND ANSWERS, UPDATED DRAWINGS

528A7-18-740 Replace 7C Patient Room Doors & Sinks RFIs - Pre-Bid Date: 4-28-25

1. Through looking at the specifications of the project, I could not find the dimensions or quantity of the BR glass that needs to be replaced. Would you happen to have that information so that we can start quoting this bid?

a. Glass is not Ballistic Glass, it’s noted as Vistamatic glass window on the prints.

2. We noticed that drawing GC-101 is on the drawing list but there is not a drawing printed.

I believe it is the ICRA Barrier drawing?

a. Updated Print will be file Named “528A7-18-740 - Replace 7C Patient Room Doors and Sinks - Drawings REV 4”

3. Refer to drawing GI-001 Drawing Index and item 2. Drawing GC-101. This drawing is not included with drawings posted on 3/13/2025.

a. Updated Print will be file Named “528A7-18-740 - Replace 7C Patient Room Doors and Sinks - Drawings REV 4”

4. Refer to drawing AD-101 General Demo Note 9. This note calls for a 1-hour fire barrier for the duration of the project. Please show the location of this barrier on the floor plan along with the location of the temporary access(s) so we can determine material and labor quantities.

a. Print’s have been updated.

5. Refer to drawing AD-101 General Demo Note 9. This note calls for a 1-hour fire barrier for the duration of the project. Please identify the wall type expected from the 18 wall types on drawing A-001, for instance Type 5 or Type 9? Or whether height Type A or D? Or other?

a. Type 6B made with high impact resistant GWB as noted.

6. Please provide a plumbing drawing showing the in-wall piping diagrams for cold and hot water, waste, vent and their proposed connections, their source and their shut-offs, i.e., everything necessary to perform the necessary plumbing work properly.

a. Plumbing Prints for the floor will be provided.

7.

See attached document: Plumbing 7C prints.

See attached document: 528A7-18-740 - Replace 7C Patient Room Doors and Sinks - Drawings REV 4.