St Albans Asbestos Survey 2010.pdf

PDF 5 MB Posted

Attached to
Y1DA--630A4-24-411 Renovate D2 Swing Space (VA-24-00028268) ST. ALBANS CAMPUS
Solicitation number
36C24224B0006
Issued by

About this file

This solicitation is for renovation services at the St. Albans campus of the New York Harbor Healthcare Center. The scope of work involves renovating the entire second floor (D2 ward) of Building 86 at the St. Albans Community Living Center to accommodate approximately 20 beds. Specific requirements include demolishing walls to convert offices and storage rooms into patient rooms; installing new fixtures, flooring, lighting, and bathroom renovations throughout; upgrading mechanical, electrical and plumbing systems; and other cosmetic upgrades. The contractor must utilize the Department of Veterans Affairs Veterans Integrated Service Network 2 Autodesk Construction Cloud platform for project collaboration and documentation. Additional requirements include completing platform training within 12 days of access and only communicating officially through the platform for the duration of the contract. The contract is for 90 calendar days from notice to proceed.

View the file

Other files

File Type Posted
36C24224B0006 0002.docx DOCX document
6 - BB85-86-2.pdf PDF
S04 SITE VISIT WELCOME LETTER.pdf PDF
36C24224B0006 0001.docx DOCX document
S04 SITE VISIT SIGN IN SHEET.pdf PDF
36C24224B0006_1.docx DOCX document
C22 ALL POSTERS.pdf PDF
S02 DRAWINGS .pdf PDF
S02 SPECS .pdf PDF
ADDITIONAL INSERTS.doc DOC document
Attachment 5 FAR 52.225-2 BUY AMERICAN CERTIFICATE.pdf PDF
C10 VA ID PACKAGE UPDATED 12-19-2023.pdf PDF
Attachment 4 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATION (1).pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Environmental Monitoring & Consulting Associates P.o. BOX 872· SOMERVILLE, NJ 08876 • (732) 249--3005· FAX (732) 24~3:3S4

ASBESTOS BUILDING SURVEY

AT

ST. ALBANS VA MEDICAL CENTER

179-00 LINDEN BOULEVARD

JAMAICA, QUEENS, NEW YORK 11425-0001

BUILDINGS 60, 64, 65, 85, 86,87,88,89,91,92,93,165,166,169,173

AND CONNECTING CORRIDORS

PREPARED BY

ENVIRONMENTAL MONITORING & CONSULTING ASSOCIATES

POST OFFICE BOX 872

SOMERVILLE, NEW JERSEY 08876-0872

(732) 249-3005

AUGUST 31, 2010

P.o. BOX 872· SOMERVILLE, NJ 08876 • (732) 249-3005· FAX (732) 249-3384

TABLE OF CONTENTS

Introduction

Asbestos Health Hazards

Analytical Techniques - Bulk Asbestos Analysis

Inspection Procedures And Limitations

Facility Description

List Of Buildings Inspected

Findings And Recommendations

Disclaimer

Table One - Estimated Quantities Of Asbestos Containing Materials Found

Table Two - Asbestos Removal Cost Estimate

Summary Of Recommendations

Asbestos Sample Location Maps

Electron Microscopy Service Labs. (EMSL) Transmission Electron Microscopy (TEM) Results

Photographic Documentation

Pages 2 - 3

Pages 6 - 8

Pages 9 - 28

Pages 30 - 103

Pages 1 - 32

Unpaged

Unpaged

P.o. BOX 87:2· SOMERVILLE, NJ 08876 • (732) 2'-19-3005· FAX (732) 249-3384

ASBESTOS BUILDING SURVEY

179-00 LINDEN BOULEV ARD

.JAMAICA, QUEENS. NEW YORK 11425-0001

INTRODUCTION

Environmental Monitoring & Consulting Associates (EM&CA) has conducted an asbestos building survey at St. Albans VA Medical Center - Buildings 60, 64, 65, 85, 86, 87, 88, 89, 91, 92, 93, 165, 166, 169, 173 and Connecting Corridors.

The enclosed asbestos building inspection and survey report includes the following:

o Locating and quantifying all asbestos containing materials;

o A visual determination as to the extent of visible and accessible suspect building materials and the conditions of the suspect materials;

o Estimation of inaccessible, concealed asbestos containing materials in radiators, pipe chases, bathrooms, etc.;

o A physical "Hands Pressure" test for determining friability and condition of suspect materials;

o Assessment of suspect friable and non-friable materials and related locations;

o Measurement of factors associated with exposure potential assessment;

o Description of analytical testing methods employed;

o Photographic documentation of samples collected and analyzed;

o Sample location maps;

o Conclusions and recommendations.

The results of the inspection integrated with the analysis of bulk samples taken are outlined in this document.

-1

P.o. sox 872· SOMERVILLE, NJ 08876 • (732) 249-3005· FAX (732) 249-33a.t

ASBESTOS HEALTH HAZARDS

Asbestos is a recognized occupational hazard. However, the presence of asbestos containing materials in a building by itself does not necessarily constitute an immediate health hazard. The potential for hazard exists if the asbestos is damaged or disturbed during building maintenance, renovations or repair and fibers are released into the surrounding atmosphere. The United States Environmental Protection Agency defines an asbestos containing material as any material that contains one percent or greater asbestos. Friable asbestos containing materials are defined as those materials that contain one percent or greater asbestos and can be easily crumbled with hand pressure to release fibers into the atmosphere and have the potential to pose a greater risk than non-friable materials.

ANAL YTICAL TECHNIQUES - BULK ASBESTOS ANALYSIS

The suspect building materials were analyzed using United States Environmental Protection Agency (USEPA) Method Number 600/R-93/116, Polarized Light Microscopy (PLM) with Dispersion staining.

The analysis involves the microscopical observation of the suspect asbestos containing materials with a stereoscopic low power microscope to determine the homogeneity of the material. Forcep samples are then immersed in a refractive index solution on a microscope slide, teased apart, covered with a cover glass, and observed with a polarized light microscope.

In accordance with New York State regulations, non-organically bound materials, such as floor tiles, mastics, roofing materials, etc. which were negative for asbestos by Polarized Light Microscopy (PLM) , were also analyzed by Transmission Electron Microscopy (TEM) at Electron Microscopy Service Labs. (EMSL).

INSPECTION PROCEDURES AND LIMITATIONS

The inspection procedures were based on the guidelines established by the Asbestos Hazardous Emergency Response Act (AHERA), as set forth in 40 CFR Part 763 of October 30, 1987.

-2

JAMAICA, OUEENS, NEW YORK 11425-0001

INSPECTION PROCEDURES AND LIMITATIONS (Continued)

The guidelines represent the most up-to-date inspection and sampling protocol available and were utilized while sampling and inspecting.

A building inspection for asbestos containing materials was performed in all accessible and visible areas of Buildings 60, 64, 65, 85, 86, 87, 88, 89, 91, 92, 93, 165, 166, 169, 173 and Connecting Corridors.

Core samples of each friable material were collected by penetration of the suspect material to it's substrate. All samples were placed in plastic bags and then sealed and labeled with an identifying code and a code log was kept. Representative samples of each sampling area were analyzed for asbestos content. The number of samples collected is determined by the number of homogeneous sampling areas present in the building. That determination is based on the judgment of the inspector. A homogeneous sampling area contains material that is uniform in color and texture. The sampling locations were chosen to obtain a representative sample and to avoid any biases that could be introduced if personal judgment alone was used.

Asbestos containing insulation materials were assigned friability ratings of 1, 2 or 3. Materials assigned with a No. 1 friability rating are not friable. Asbestos containing insulation materials found to have low friability have been assigned a No. 2 friability rating (difficult but possible to damage by hand). Highly friable asbestos insulation is given a No.3 rating (fluffy, spongy or flaking).

Due to the occupied status of the building, EM&CA was limited in the number and location of floor tile and floor tile mastic samples and roofing samples that could be collected. It is recommended that, if an area is going to be demolished or renovated, additional sampling may be required to confirm the presence or absence of asbestos floor tiles, mastics and roofing materials.

At the request of the client, Buildings 64, 65, 85 (except Penthouse Elevator Motor Room Root), 86, 87, 90, 91 and 173 roofs were not tested.

Due to environmental hazards, Building 90 was not inspected and tested. However, this area was previously inspected in 1989 by Hygienetics Inc. and their survey data was included in this report.

-3

P.o. BOX 872· SOMERVILLE, NJ 08876 • (73:2) 249-3005. FAX (732) 24~33a.t

FACILITY DESCRIYfION·

The St. Albans Extended Care Center was built in approximately 1948 and consists of Buildings 85, 86,87,88,89,90,91,92 and 93 joined by three-story plus basement connecting corridors. The central structure is comprised of Building 89 (Administration Building) and Building 88 (Subsistence Building). The remaining buildings are arranged symmetrically about Building 88, 89, with Buildings 85 ("C" Building), 86 ("D" Building) and 87 ("B" Building) to the east and Building 91 ("E" Building), 92 and 93 ("F" Buildings) to the west.

The four other buildings included in the survey are Building 60 (Guard House), Building 64 (Boiler Plant), Building 65 (Garage) and Building 173 (Laundry Building).

Steam, hot water and cold water are distributed throughout the floors via perimeter pipe risers with the steam lines servicing perimeter radiators and HVAC systems. Building 65 is a wooden-roofed, one story, brick structure attached to Building 64. The building features an elevated roof over the garage area which was designed for maintenance of larger vehicles. There is one second floor office constructed on the building's south perimeter. The building's exterior finish is brick.

The central structure buildings are constructed with steel framing and poured-in-place concrete. Heat is supplied via high pressure steam lines traveling through steam tunnels from Building 64 (Boiler Plant). The external finish for these buildings is brick. Interior finishes include concrete, terrazzo and tiled floors and concrete, sheetrock and cinderblock walls. Originally, ceilings on a wire lath had been hung in most areas of the buildings, except basements. In other areas, one foot by one foot granular ceiling tiles were glued directly onto the concrete decking. In later years, however, suspended acoustic tile ceilings have been hung below the original ceilings in most areas.

There are two active steam tunnels at the facility. The first one, hereafter referred to as Steam Tunnel #1, begins in Building 64 and terminates at an aluminum shed located between Building 64 and Building 173.

Steam Tunnel #2 is a longer, more complex tunnel running from Building 64 to the Building 89 Mechanical Equipment Room adjacent the Loading Dock. This tunnel also has an extension which connects to Building 88, Room A. Both steam tunnels have been recently abated.

-4

P.o. BOX 872 4 SOMERVILLE. NJ 08876 • (732) 249-3005 • FAX (732) 249-3384

LIST OF BUILDINGS INSPECTED

The following table is a listing of all buildings inspected in this survey, year constructed, description, floors and gross square footages.

LIST OF BUILDINGS INSPECTED

BUILDING YEAR BUILT DESCRIPTION FLOORS GROSS SQUARE FOOTAGES

60 1948 Guard House 1 924

64 1948 Boiler Plant 2 28,706

65 1948 Garage 1 23,258

85 1948 Intermediate Care Ward C 5 41,564

86 1948 Intermediate Care Ward D 5 41,564

87 1948 Nursing Care Ward B 4 48,755

88 1948 Dietetics BuildingIDomiciliary S 3 124,224

89 1948 AdministrationlNursing Care Ward A 8 179,473

91 1948 Nursing Care Ward E 4 38,808

92 1948 Nursing Care Ward F 5 41,564

93 1948 Nursing Care Ward F 5 39,094

165 1960 NYS Drug Treatment Building - J Cap 4 24,454

166 1960 NYS Drug Treatment Building - J Cap 4 8,838

169 ------ Substation 1 ----- 173 1980 Laundry Building 2 63,335

CC 1948 Connecting Corridors 4 21,960

TOTAL GROSS FLOOR AREA 726,521

-5

P.o. BOX 872· SOMERVILLE. NJ 08876 • (732) 249-3005· FAX (732) 242-338.4

JAMAICA, QUEENS, NEW YORK 11425·0001

FINDINGS AND RECOMMENDATIONS

The estimated quantities of asbestos containing materials found are indicated in the attached Table One.

The majority of the asbestos containing materials found in the facility consists of thermal system insulation, such as pipe and fitting insulation, duct insulation and radiator heat shield insulation. The asbestos pipe and fitting insulation inside the perimeter columns and asbestos radiator heat shield insulation in Buildings 85, 86, 87, 88, 89, 91, 92 and 93 were assumed, since access was limited in these areas. Sprayed-on fireproofing was found in the auditorium in Building 88. Miscellaneous asbestos containing materials found throughout the facility consist of vinyl asbestos floor tiles and mastic, asbestos fire doors and asbestos cloth materials, such as the fire curtain in the auditorium.

The majority of asbestos materials are in good condition and only requires routine inspection and maintenance to assure that these materials remain in good condition, except for the friable duct and pipe insulation in both the Building 88 auditorium and gymnasium which are in poor condition.

According to the chief engineer, the auditorium is kept locked and not used because of the asbestos.

Materials, such as the vinyl asbestos floor tiles and roofing materials, are non-friable and do not pose any hazard unless renovation of maintenance impacts them causing the release of fibers.

In addition to keeping the auditorium locked, it is recommended that all auditorium return air ducts be sealed off to prevent airborne asbestos fibers from being recirculated into occupied building areas.

Highly friable asbestos pipe and fitting insulation was found outside Building 64 (Boiler Plant) adjacent to the overhead railroad tracks. Friable asbestos pipe insulation was also found inside Building 64 on the mezzanine level catwalk. Both of these two areas need to be addressed as soon as possible.

Highly-friable asbestos pipe insulation and joint duct insulation exist in the Building 88, grade level gymnasium above the drop ceiling and need to be addressed.

All asbestos containing materials found in the facility during the survey have been assessed and given a hazard priority rating of one (low friability), two (medium friability) and three (high friability).

-6

P.o. sox 872· SOMERVILLE, NJ 08876 • (732) 249-3005· FAX (732) 249-3384

FINDINGS AND RECOMMENDATIONS (Continued)

All bulk sample analysis results, material quantities and locations and friability are located on the summary of recommendations' forms in addition to the survey drawings and photographs. All documents are meant to be used with one another to locate asbestos materials in the building in conjunction with future building renovations or surveys.

EM&CA recommended that a formal operations and maintenance program be implemented for all of the asbestos containing radiator heat shield insulations, asbestos pipe and fitting insulation materials, asbestos insulated ductwork, asbestos fireproofing, asbestos floor tiles and mastic and asbestos roofing and flashing materials.

This program is necessary because of the amount and variety of asbestos containing materials within the facility. At a minimum, the program should include the following six basic elements:

1) hnplementation on a plan for immediate abatement of materials which represent a possible exposure risk. The friable asbestos containing materials previously mentioned in this report need to be addressed immediately. Any asbestos containing materials found in areas where demolitions or renovations are to begin should be dealt with immediately.

2) Prompt cleanup of any asbestos debris which has resulted from impacting or deterioration of asbestos containing materials in the building. Friable asbestos containing debris was found outside Building 64 (Boiler Plant).

3) Development and implementation of controls for routine maintenance and renovation activities which could either disturb existing asbestos containing materials or require subsequent removal of small sections of asbestos containing materials.

4) Designation of a "Program Coordinator" within the facilities management staff to administer the program activities and recordkeeping needs.

5) Educate the building employees in the management program and the manner in which it eliminates their possible exposure risk.

-7

P.o. BOX 872 • SOMERVILLE, NJ 08876 • (732) 249-3005 • FAX (732) 249-3384

.JAMAICA, OUEENS, NEW YORK 11425-0001

FINDINGS AND RECOMMENDATIONS (Continued)

6) Maintaining formal program records (i.e., an overall written policy and procedures for the maintenance and renovation controls, air monitoring results, etc.).

DISCLAIMER:

The St. Albans VA Medical Center was occupied at the time of our inspection and access was limited.

Additional sampling and testing may be required in the future.

No wall, ceiling or access holes were made for this inspection.

Due to electrical hazards, most electrical cable wrap was not sampled and tested.

Ceramic tiles and underlying waterproofing membranes were not inspected and tested.

-8

P.o. BOX 872· SOMERVILLE, NJ 08876 • (732) 249-3D05· FAX (732) 249-3384

JAMAICA. QUEENS. NEW YORK 11425-0001

TABLE ONE

ESTIMATED OUANTITIES OF ASBESTOS CONTAINING MATERIALS FOUND

LOCATION

Building 60 - Guard House And Booth:

Building 64 - Boiler Plant:

BasementJLaboratory And Boiler Room

Boiler RoomlMezzanine LeveV Catwalk

Ground LeveVRoom 1

Outside Building Near Railroad Tracks

Building 65 - Garage:

First Floor/Storage Room

First Floor/Shop Area, Garage And Bathrooms

First F1oorlDriver's Room And Bathroom

First Floor/Carpenter's Shop

First F1oorlHazardous Materials Storage

ASBESTOS CONTAINING MATERIAL

None Present

Asbestos Pipe And Fitting Insulation

Asbestos Pipe And Fitting Insulation

12" x 12" White Streaked Floor Tile Above 9" x 9" Black Asbestos Floor Tile Above 9" x 9" Brown Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Pipe And Fitting Insulation

9" x 9" Black Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Pipe And Fitting Insulation

12" x 12" Grey Floor Tile Above 12" x 12" Yellow Floor Tile Above 12" x 12" White Floor Tile And Black Asbestos Mastic

12" x 12" Dark Blue Asbestos Floor Tile And Black Mastic

12" x 12" Beige Streaked Asbestos Floor Tile And Brown Mastic

-9

OUANTITY

225 LF

60LF

210 SF

240LF

500 SF

850LF

306 SF

180 SF

1,144 SF

P.o. BOX 872· SOMERVILLE. NJ 08876 • (732) 2~9-30DS. FAX (732) 249-3384

ESTIMATED QUANTITIES OF ASBESTOS CONTAINING MATERIALS FOUND

LOCATION

Building 65 - Garage ... Continued:

Mezzanine LeveVPlumbing Shop Office

Building 85:

Basement

First Floor

First Floor/Corridor, Nurses' Manager C-103, Nurses' Lounge C-I04, Smoking Room C-I04B, Ward Supplies C-105, Patient Bedrooms C-l06, C-l 07, C-l08 And C-109, Laundry Room C-l1l, Solarium C-l13, Nurses' Station C-124 And Recreation Room C-125

Second Floor

ASBESTOS CONTAINING MATERIAL

12" x 12" Tan Streaked Asbestos Floor Tile And Brown Mastic

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Window Caulking

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Beige With Blue And Black Streaks Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

QUANTITY

575 SF

1,185 LF

1,610 LF

1,824 LF

38 Windows

765 SF

1,395 LF

1 Door

550LF

750 SF

765 SF

-10

P.o. BOX 872 ~ SOMERVILLE, NJ 08876 • (732) 2~9-3D05. FAX (732) 24~3384

LOCATION

Building 85 ... Continued:

Second Floor. ..Continued

Second Floor

Third Floor

Building 86:

Basement

First Floor

Second Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

QUANTITY

1,230 LF

750 SF

388 LF

630LF

1,300 LF

750 SF

1,395 LF

2 Doors

750 SF

1,230 LF

2 Doors

-11

P.o. BOX 872· SOMERVILLE, NJ 08876 • (732) 249-3005· FAX (732) 249-338.4

LOCATION

Building 86...Continued:

Second Floor ... Continued

Second Floor

Third Floor

Building 87:

Basement

First Floor

Second Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

QUANTITY

705LF

705 SF

376LF

480LF

450LF

660 SF

1,230 LF

2 Doors

615 SF

1,395 LF

-12

P.o. BOX 872 • SOMERVILLE, NJ 08876 • (732) 249--3005 • FAX (132) 2a~3384

JAMAICA. QUEENS, NEW YORK 11425-0001

LOCATION

Building 87... Continued:

Third Floor

Fifth FloorlElevator Machine Room Roof

Building 88:

Grade Level

Grade Level/Commissary Lounge

Grade Level/Commissary Stairwell Handicap Ramp

Grade LevellBowling Alley Rear Pin Area

Grade Level/Gymnasium

Basement, First And Second Floors

First Floor South/Auditorium Vestibule

ASBESTOS CONTAINING MATERIAL

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Caulking Between And Below Rooftop Parapet Wall Blocks

Asbestos Pipe And Fitting Insulation Above Drop AndlOr Plaster Ceilings And Inside Pipe Chases

12" x 12" Beige Streaked Floor Tile And Black Asbestos Mastic

12" x 12" Red Floor Tile And Yellow Asbestos Mastic

9" x 9" Brown Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Pipe And Fitting Insulation

Asbestos Joint Compound On Cork Duct Insulation

Asbestos Window Caulking

9" x 9" Blue Streaked Asbestos Floor Tile And Black Asbestos Mastic

-13

QUANTITY

600 SF

312LF

130LF

1,170LF

450 SF

80 SF

280 SF

620LF

3,000 SF

3,220LF

115 Windows

300 SF

P.o. BOX 872 ~ SOMERVILLE, NJ 08876 a (732) 249--3005. FAX (732) 249-3384

LOCATION

Building 88 ... Continued:

First Floor ... Continued

First Floor South/Auditorium Stage

First Floor SouthIRoom S-147

First Floor South!Stage Air Handler Room

First Floor SouthlRoom S-152, Corridor And Offices

First Floor South! Auditorium

First Floor SouthlExamination Room S-140 And Adjacent Examination Rooms

First Floor SouthlExamination Room S-180 And Adjacent Examination Rooms

Second Floor/AA Resident Bedrooms, Mailbox Area And Dormitory

Second FloorlRecreation Room

Auditorium/Attic

ASBESTOS CONTAINING MATERIAL

Asbestos Fire Curtains

9" x 9" Brown Streaked Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Pipe And Fitting Insulation

12" x 12" Beige Streaked Floor Tile Above 9" x 9" Brown Asbestos Floor Tile And Black Asbestos Mastic

9" x 9" Grey Asbestos Floor Tile And Black Asbestos Mastic Below Carpet

12" x 12" Beige With Brown Streaks Floor Tile And Black Asbestos Mastic

12" x 12" Light Grey With Grey Streaks Floor Tile And Black Asbestos Mastic

12" x 12" White With Grey Streaks Floor Tile And Brown And Black Asbestos Mastic

9" x 9" Green Asbestos Floor Tile And Black Asbestos Mastic Below Carpet

Brown Duct Insulation Above Grey Asbestos Joint Compound

-14

QUANTITY

1,500 SF

305 SF

265 LF

790 SF

6,650 SF

1,572 SF

840 SF

7,000 SF

900 SF

11,200 SF

P.o. BOX 872· SOMERVILLE, NJ 08876 • (732) 249-3005" FAX (732) 249-3384

LOCATION

Building 88...Continued:

Auditorium ... Continued

Auditorium!AtticlNorth And South Perimeter Walls

Auditorium! AtticlPerimeter Walls

Building 89:

North BasementiMain Corridor, Bathroom And Adjacent Rooms

North Basement/Canteen And Canteen Storage

North Basement/Air Handler RoomA-23

South BasementiMain Corridor, Cooks' Lounge And Adjacent Rooms

South Basement/Corridors, Rooms A-27, A-28, A-37, A-39, A-41, A-43, A-49 And A-59

South Basement

Basement

ASBESTOS CONTAINING MATERIAL

Spray-On Asbestos Fireproofing And Black Asbestos Mastic

Asbestos Electric Cable Insulation From Spotlights

Asbestos Pipe And Fitting Insulation

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" White With Grey Streaks Floor Tile And Black Asbestos Mastic

Asbestos Fitting Insulation On Fiberglass Insulated Pipes

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Beige Streaked Floor Tile And Black Asbestos Mastic

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Window Caulking

QUANTITY

9,500 SF

88 LF

30LF

1,650LF

1,825 SF

30 Fittings

1,970LF

7,108 SF

900LF

1,176 LF

42 Windows

-15

JAMAICA. QUEENS. NEW YORK 11425-0001

LOCATION

Building 89 ... Continued:

First Floor North

First Floor NorthIRooms 123, 123B And 123C

First Floor South

Second Floor

Second Floor/Corridor, Lounge A-253 And Dental Storage RoomA-245

Third Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Tan Asbestos Floor Tile And Brown Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Brown Streaked Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

QUANTITY

825 SF

1,680 LF

605 LF

500 SF

600 SF

900LF

755 LF

1,185 SF

2,070 LF

1,151 LF

1,342 SF

1,140 SF

2,280LF

-16

P.o. BOX 872 ~ SOMERVILLE, NJ 08876 • (732) 2~9-3DOS· FAX (732) 249-3384

.JAMAICA. QUEENS, NEW YORK 11425-0001

LOCATION

Building 89 ... Continued:

Third Floor ... Continued

Third Floor

Third Floor/Exposure Room Two A-349

Third FloorlX-Ray Room A-355

Third FloorlPatient Film Storage RoomA-359

Third Floor/Corridor Adjacent X-Ray Room A-355

Third Floor/Corridor Outside X-Ray Department

Third Floor/Corridor

Third Floor/Corridor Adjacent RoomA-337

Third Floor/Office Rooms A-320, A-324 And A-326A

Fourth Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" White With Grey Streaks Asbestos Floor Tile And Black Asbestos Mastic

12" x 12" Brown With White Specks Asbestos Floor Tile And Black Asbestos Mastic

9" x 9" Green Asbestos Floor Tile And Black Asbestos Mastic

12" x 12" Green With Light Green Streaks Asbestos Floor Tile And Black Asbestos Mastic

12" x 12" Pink With Black Specks Asbestos Floor Tile And Black Asbestos Mastic

12" x 12" Pink With Black Specks Floor Tile And Black Asbestos Mastic

12" x 12" Dark Green With White Streaks Asbestos Floor Tile And Black Mastic

9" x 9" Dark Green Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

-17

QUANTITY

350LF

340 SF

300 SF

245 SF

560 SF

650 SF

2,345 SF

400 SF

600 SF

930 SF

1,830 LF

P.o. BOX 872· SOMERVILLE, NJ 08876 ~ (732) 249-3005· FAX (732) 24~3384

.JAMAICA, QUEENS, NEW YORK 11425-0001

LOCATION

Building 89 ... Continued:

Fifth Floor

Sixth Floor

Seventh Floor/Corridor

Seventh Floor/Stairwell

Seventh FloorlMain North And South Roofs

Ninth FloorlElevator Machine Room Roof

Building 90:

Basement

ASBESTOS CONTAINING MATERIAL

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Dark Brown Streaked Floor Tile And Black Asbestos Mastic

Asbestos Pipe And Fitting Insulation

Asbestos Roofing Material

Asbestos Roofing Material

Asbestos Pipe And Fitting Insulation

Asbestos Pipe And Fitting Insulation

9" x 9" White, Black And Red Asbestos Floor Tile And Mastic

12" x 12" White Asbestos Floor Tile And Mastic

QUANTITY

945 SF

1,875 LF

630 SF

500LF

1,615 LF

556 SF

60LF

10,000 SF

300 SF

60LF

20LF

1,900 SF

781 SF

-18

P.o. BOX 872· SOMERVILLE, NJ 08876 • (732) 249-3DD5. FAX (732) 249-3384

LOCATION

Building 90 ... Continued:

Basement. ..Continued

Basement

First Floor

Building 91:

Basement

BasementIRooms E-23, E-27 And E-33

BasementIRoom E-47 Closet And Corridor

First Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Duct Insulation

Asbestos Ceiling Plaster

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

9" x 9" Asbestos Floor Tile And Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

9" x 9" Green Streaked Asbestos Floor Tile And Black Asbestos Mastic

12" x 12" Red Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

QUANTITY

30 SF

450 SF

195 SF

I04LF

1,080 SF

360 SF

nOLF

1,305 LF

670 SF

409 SF

630 SF

1,275 LF

-19

LOCATION

Building 91...Continued:

First Floor. ..Continued

First Floor

Basement And First Floor/ East Side

First Floor/Corridor Adjacent Room E-I05

First FloorlRoom E-117

Second Floor

Third Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Window Caulking

12" x 12" White With Black Streaks Asbestos Floor Tile And Black Mastic

12" x 12" Brown Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" White Floor Tile Above 12" x 12" Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

-20

OUANTITY

260LF

644LF

21 Windows 2 Vents

376 SF

450 SF

600 SF

1,200LF

840LF

2,042 SF

630 SF

1,200 LF

P.o. BOX a72" SOMERVILLE, NJ 08878 • (732) 249-3005 • FAX (732) 249-33M

JAMAICA. OUEENS. NEW YORK 11425-0001

LOCATION

Building 91... Continued:

Third Floor ... Continued

Third Floor

Third FloorlRoom E-329

Fifth FloorlElevator Machine Room Roof

BuUding92:

Basement

Basement

BasementlLadies' Locker Room And HV AC Shop Rooms

BasementlMen's Locker Room And Shower Room

First Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" X 12" Beige Streaked Asbestos Floor Tile And Black Mastic

Asbestos Caulking Between And Below Rooftop Parapet Wall Blocks

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Window Caulking

12" X 12" Blue Streaked Asbestos Floor Tile And Black Mastic

12" X 12" Tan With Red Streaks Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

-21

QUANTITY

735LF

450 SF

130LF

600LF

1 Door

1,975 LF

840LF

30 Windows

825 SF

1,942 SF

705 SF

1,470LF

P.O. BOX 872· SOMERVILLE, NJ 08876 ~ (732) 249-3005· FAX (732) 24~3384

LOCATION

Building 92 ... Continued:

First Floor. ..Continued

First Floor

First FloorlRoom F-343 And Solarium

Second Floor

Second Floor/Solarium F-247

Third Floor

RoofINorth Side

ASBESTOS CONTAINING MATERIAL

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Grey Streaked Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Grey Streaked Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Roofing Material

727 LF

416SF

735 SF

1,470 LF

431 LF

416SF

720 SF

285 LF

9,100 SF

-22

P.o. BOX 87'2:· SOMERVILLE. NJ 08876 • (732) 249-3005· FAX (732) 24~3384

179·00 LINDEN BOULEVARD

LOCATION

Building 93:

Basement

First Floor

First FloorlRoom F-113

Second Floor

Second Floor/Solarium F-213

ASBESTOS CONTAINING MATERIAL

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Grey Streaked Asbestos Floor Tile And Black Mastic

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Grey Streaked Asbestos Floor Tile And Black Mastic

QUANTITY

600LF

2 Doors

2,495 LF

720 SF

1,470LF

550LF

416 SF

735 SF

513 LF

416 SF

-23

P.o. BOX 872 • SOME RVILLE. NJ 08876 • (732) 24~005 • FAX (732) 24~33S4

JAMAICA, QUEENS, NEW YQRK 11425-0001

LOCATION

Building 93 ... Continued:

Third Floor

Third Floor/Solarium F-314

Fifth FloorlElevator Machine Room Roof

Building 165 - .J CAP:

First Floor/Kitchen And Supervisor's Office

First Floor

Entire First Floor, Except Bathrooms, Fire Alarm Room And Closets

Second Floor

ASBESTOS CONTAINING MATERIAL

Asbestos Containing Radiator Heat Shield Insulation

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

Asbestos Fire Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases

12" x 12" Grey Streaked Asbestos Floor Tile And Black Mastic

Asbestos Roofing Material

Asbestos Caulking Between And Below Rooftop Parapet Wall Blocks

12" x 12" Black And Orange Floor Tile Above 9" x 9" White Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Fitting Insulation On Fiberglass Insulated Pipes Inside Perimeter Columns

Asbestos Roofing And Flashing Material

12" x 12" Orange, Green And White Streaked Floor Tile Above 9" x 9"Grey Streaked Asbestos Floor Tile And Black Asbestos Mastic

9" x 9" Grey Streaked Asbestos Floor Tile And Black Asbestos Mastic

QUANTITY

705 SF

1,470 LF

2 Doors

165 LF

416 SF

9,100 SF

180LF

180 SF

156 Fittings

900 SF

5,976 SF

5,080 SF

-24

P.o. BOX 872 ~ SOMERVILLE, NJ 08876 • (732) 249-3005 • FAX (732) 249-3364

ASBESTOS BIDLDING SURVEY

LOCATION

BOOding 165 - J CAP...Continued:

Second F1oor ... Continued

Second Floor

Second F1oorlRoof

Third Floor

BOOding 166 - J CAP:

BasementIBoiler Room And Maintenance Office

First Floor

Second Floor

Third Floor

BOOding 169 - Substation:

ASBESTOS CONTAINING MATERIAL

Asbestos Fitting Insulation On Fiberglass Insulated Pipes Inside Perimeter Columns

Asbestos Roofing And Flashing Material

9" X 9" Grey Streaked Asbestos Floor Tile And Black Asbestos Mastic

Asbestos Roofing And Flashing Material

Asbestos Fitting Insulation On Fiberglass Insulated Pipes

12" X 12" Orange And White Floor Tile Above 9" x 9" White Asbestos Floor Tile And Black Mastic

Asbestos Fitting Insulation On Fiberglass Insulated Pipes Inside Perimeter Columns

12" X 12" White With Grey Streaks Asbestos Floor Tile And Black Mastic

Asbestos Fitting Insulation On Fiberglass Insulated Pipes Inside Perimeter Columns

12" X 12" White With Grey Streaks Asbestos Floor Tile And Black Mastic

Asbestos Roofing And Flashing Material

None Present

-25

OUANTITY

120 Fittings

3,020 SF

3,360 SF

6,030 SF

85 Fittings

2,284 SF

50 Fittings

1,720 SF

40 Fittings

1,720 SF

3,270 SF

P.o. BOX 812 • SOMERVILLE, NJ 08876 • (732) 2a~005 FAX (732) 24~33846

LOCATION ASBESTOS CONTAINING MATERIAL QUANTITY

Building 173 - Laundry Building:

First FloorlLunchroom, Offices 12" x 12" Beige With Brown Streaks Floor Tile Above 2,756 SF And Storage Rooms 12" x 12" Tan With Pink Specks Floor Tile And Black

Asbestos Mastic

First FloorlLocker Room 12" x 12" Brown With Grey Streaks Floor Tile And 345 SF Black Asbestos Mastic

First FloorlLaundry Room And 12" x 12" Pink Streaked Floor Tile And Black Asbestos 21,075 SF Storage Rooms Mastic

Connecting Corridors:

Basement Asbestos Containing Radiator Heat Shield Insulation 900 SF

Asbestos Pipe And Fitting Insulation Inside Perimeter 1,840 LF Columns

BasementJFrom Building 85/86 Asbestos Pipe And Fitting Insulation 820LF To Building 89

BasementJFrom Building 89 To Asbestos Pipe And Fitting Insulation 1,020LF Building 92/93

First Floor Asbestos Containing Radiator Heat Shield Insulation 750 SF

12" x 12" Pink With Black Spots Floor Tile And 2,050 SF Black Asbestos Mastic

Asbestos Pipe And Fitting Insulation Inside Perimeter 1,500 LF Columns

-26

Environmental Monitoring & Consulting Assoclate$

.JAMAICA, QUEENS, NEW YORK 11425-0001

LOCATION ASBESTOS CONTAINING MATERIAL OUANTITY

Connecting Corridors ... Continued:

Basement, First, Second And Asbestos Window Caulking 1,680 LF Third FloorslFrom Building 87 60 Windows To Building 89/East And West Sides

Basement, First, Second And Asbestos Window Caulking l,680LF Third FloorslBetween Building 89 60 Windows To Building 91INorth And South Sides

Basement, First, Second And Asbestos Window Caulking 1,176 LF Third FloorslBetween Building 91 42 Windows To Building 92/93INorth And South Sides

Second Floor Asbestos Containing Radiator Heat Shield Insulation 900 SF

Asbestos Pipe And Fitting Insulation Inside Perimeter 1,800LF Columns

Third Floor Asbestos Containing Radiator Heat Shield Insulation 900 SF

Asbestos Pipe And Fitting Insulation Inside Perimeter 480LF Columns

NOTE: See Grand Totals listed on Page 28.

-27

P.o. BOX 872· SOMERVILLE, NJ 08876 • (732) 2~9-3DDS· FAX (732) 249-33a..t

179·00 LINDEN BOULEVARD

LOCATION ASBESTOS CONTAINING MATERIAL QUANTITY

GRAND TOTALS: Asbestos Containing Radiator Heat Shield Insulation 22,800 SF

Asbestos Pipe And Fitting Insulation Inside Perimeter Columns

43,390 LF

Asbestos Fire Doors 32 Doors

Asbestos Pipe And Fitting Insulation Above Drop And/Or 24,192 LF Plaster Ceilings And Inside Pipe Cbases

Asbestos Fire Curtains 1,500 SF

Asbestos Pipe And Fitting Insulation 4,270 LF

Asbestos Fitting Insulation On Fiberglass Insulated Pipes 481 Fittings

9" X 9" And 12" x 12" Asbestos Floor Tile And 99,154 SF Asbestos Mastic

Asbestos Duct Insulation 14,230 SF

Spray-On Asbestos Fireproofing And Asbestos Mastic 9,500 SF

Asbestos Electric Cable Insulation From Spotlights 88LF

Asbestos Roofing And Flashing Material 41,720 SF

Asbestos Ceiling Plaster 450 SF

Asbestos Window Caulking 12,240 LF 408 Windows 2 Vents

Asbestos Caulking Between And Below Rooftop Parapet 440 LF Wall Blocks

-28

P.o. BOX 812· SOMERVILLE, NJ 08876 • (732) 2~9-3005· FAX (732) 249-3384

TABLE TWO

ASBESTOS REMOVAL COST ESTIMATE

(22,800 Square Feet Asbestos Containing Radiator Heat Shield Insulation) ($30.00/SF)

(43,390 Lineal Feet Asbestos Pipe And Fitting Insulation Inside Perimeter Columns) ($30.00ILF)

(32 Asbestos Fire Doors) ($200.00lDoor)

(24,192 Lineal Feet Asbestos Pipe And Fitting Insulation Above Drop And/Or Plaster Ceilings And Inside Pipe Chases) ($30.00ILF)

(1,500 Square Feet Asbestos Fire Curtains) ($10.00/SF)

(4,270 Lineal Feet Asbestos Pipe And Fitting Insulation) ($30.00ILF)

(481 Fittings Asbestos Fitting Insulation On Fiberglass Insulated Pipes) ($30.00lFitting)

(99,154 Square Feet 9" x 9" And 12" x 12" Asbestos Floor Tile And Asbestos Mastic) ($1O.00/SF)

(14,230 Square Feet Asbestos Duct Insulation) ($35.00/SF)

(9,500 Square Feet Spray-On Asbestos Fireproofing And Asbestos Mastic) ($35.00/SF)

(88 Lineal Feet Asbestos Electric Cable Insulation From Spotlights) ($40.00ILF)

(41,720 Square Feet Asbestos Roofing And Flashing Material) ($1O.00/SF)

(450 Square Feet Asbestos Ceiling Plaster) ($40.00/SF)

(12,240 Lineal Feet Asbestos Window Caulking) ($3.00ILF)

(440 Lineal Feet Asbestos Caulking Between And Below Rooftop Parapet Wall Blocks) ($3.00ILF)

TOTAL:

NOTES: 1)

2) 3) 4)

Above prices may vary significantly ±30%.

Reinsulation not included.

Demolition and reconstruction costs not included.

Engineering and air monitoring costs not included.

-29

$ 684,000.00

$1,30 1,700.00

$ 6,400.00

$ 725,760.00

$ 15,000.00

$ 128,100.00

$ 14,430.00

$ 991,540.00

$ 498,050.00

$ 332,500.00

$ 3,520.00

$ 417,200.00

$ 18,000.00

$ 36,720.00

$ 1,320.00

$5,174,240.00 http:5,174,240.00 http:1,320.00 http:36,720.00 http:18,000.00 http:417,200.00 http:3,520.00 http:332,500.00 http:498,050.00 http:991,540.00 http:14,430.00 http:128,100.00 http:15,000.00 http:725,760.00 http:6,400.00 http:1,700.00 http:684,000.00

I~I~ p.o. BOX 872 • SOMERVILLE, NJ 08876 • (732) 249-3005 • FAX (732) 249-3384

SUMMARY OF RECOMMENDATIONS

-30

ST. ALBANS V A MEDICAL CENTER

BUILDING 60 - GUARD HOUSE

I W, I

SAMPLEID LOCATIONIDESCRIPTION QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-60-001

STA-60-002

STA-60-003

STA-60-004

STA-60-004M

STA-60-005T

STA-60-005B

First FloorlRooflSouth Side/Sample Of Roofing Shingle

BasementIFurnace RoomlHeater Exhaust Duct/Sample Of Joint Compound

Basement/Corridor/Sample Of Sheetrock Ceiling

Basement/Locker Room/Sample Of 12" x 12" Beige Streaked Floor Tile

BasementILocker Room/Sample Of 12" x 12" Beige Streaked Floor Tile Yellow Mastic

First Floor/Gun Cleaning Room/Sample Of 12" x 12" Brown Streaked Floor Tile Above 12" x 12" Beige Streaked Floor Tile

First Floor/Gun Cleaning Room/Sample Of 12" x 12" Beige Streaked Floor Tile Below 12" x 12" Brown Streaked Floor Tile

2,550 SF

6LF

200 SF

400 SF

See Sample

STA-60-004

663 SF

See Sample

STA-60-00ST

I

Tar Cellulose Fibers Quartz

Non-Fibrous........................... 1 00

Gypsum Cellulose Fibers

Non-Fibrous Cellulose Fibers Binders

Tar

Non-Fibrous Cellulose Fibers ......... , Binders

Non-Fibrous Cellulose Fibers Binders

Negative For Asbestos By

TEM

Negative For Asbestos By TEM - Same As Sample #

STA-60-00SB

Negative For Asbestos By TEM - Same As Sample #

ST A-60-005M

Negative For Asbestos By

TEM

Negative For Asbestos By

TEM

NOTES:

*Degree Of Friability

I. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

3. High Friability (Fluffy, Spongy Or Flaking)

New York State ELAP # II058

BUILDING 60 - GUARD HOUSE

111"'____ ""''''..........'_._,_

W N I

SAMPLEID LOCA TIONIDESCRIPTION QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-60-005M First Floor/Gun Cleaning Room/Sample Of 12" x 12" Brown Streaked Floor Tile Above 12" x 12" Beige Streaked Floor Tile Yellow Mastic

See Sample

STA-60-005T

1 Tar....................................... l00 Negative For Asbestos By

TEM

NOTES:

*Degree Of Friability

1. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

3. High Friability (FluffY, Spongy Or Flaking)

New York State ELAP #11058

""~n~~~",.. ~"'c"4roi~.....~lO')~.~ 4,~~'~~.~~~~1'.1I1!

BUILDING 64 - BOILER PLANT

SAMPLEID LOCATIONIDESCRIPTION QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS I

STA-64-001T Ground LeveVRoom IlField Office/Sample Of 12" x 12" White Streaked Floor Tile Above 9" x 9" Black Floor Tile Above 9" x 9" Brown Floor Tile

210 SF 1 Non-Fibrous Cellulose Fibers Binders

O&M

STA-64-001C Ground LeveVRoom IlField Office/Sample Of9" x 9" Black Floor Tile Above 9" x 9" Brown Floor Tile Below 12" x 12" White Streaked Floor Tile

See Sample

STA-64-00IT

I Chrysotile Asbestos Calcite Quartz Binders

O&M

STA-64-001B Ground LeveVRoom IlField Office/Sample Of 9" x 9" Brown Floor Tile Below 9" x 9" Black Floor Tile Below 12" x 12" White Streaked Floor Tile

See Sample

STA-64-00 1 T

1 Chrysotile Asbestos Non-Fibrous............... '" Binders

O&M

STA-64-001M Ground LeveVRoom IlField Office/Sample Of 12" x 12" White Streaked Floor Tile Above 9" x 9" Black Floor Tile Above 9" x 9" Brown Floor Tile Black Mastic

See Sample

STA-64-00 1 T

1 Chrysotile Asbestos Tar

O&M

STA-64-002 Ground LeveVRoom 2/Sample Of 12" x 12" Beige Streaked Floor Tile

210 SF 1 Non-Fibrous Cellulose Fibers Binders

Negative For Asbestos By

TEM

STA-64-002M Ground LeveVRoom 2/Sample Of 12" x 12" Beige Streaked Floor Tile Brown Mastic

See Sample

STA-64-002

1 Tar....................................... 100 Negative For Asbestos By

TEM

NOTES:

*Degree Of Friability New York State ELAP #11 058

1. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

3. High Friability (Fluffy, Spongy Or Flaking)

..j::>.

I

SAMPLEID LOCA TIONIDESCRIPTION QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-64-003 Mezzanine LeveVBoiler Room/CatwalkJ Southwest Comer/Sample Of Pipe Insulation

60LF 2-3 Chrysotile Asbestos ................... , 30 Cellulose Fibers Binders

Remove

STA-64-004 Mezzanine LeveVBoiler Room/CatwalkJ Sample Of Tank Insulation

720 SF 2 Cellulose Fibers Fiberglass Non-Fibrous

STA-64-005 Basement/Control Room/Sample Of 12" x 12" Beige Streaked Floor Tile

200 SF 1 Non-Fibrous Cellulose Fibers.......... .. . . . .. . .. .. ... I Binders

Negative For Asbestos By TEM - Same As Sample #

STA-64-002

STA-64-006 BasementIBoiler Room/Southwest Comer/ Sample Of Pipe Insulation

75 LF 2 Chrysotite Asbestos Cellulose Fibers Binders

O&M

STA-64-007 Basement/Incinerator Room/Sample Of Brick Inside Incinerator

600 SF I Cementitious MateriaL .............. 100 -------...

STA-64-008 BasementlLaboratory/Sample Of Pipe Insulation

150 LF 2 Amosite Asbestos ChrysotiJe Asbestos Calcium Silicate Binders

O&M

NOTES:

*Degree Of Friability New York State ELAP # II 058

I. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

JAMAICA, QUEENS. NEW YORK 11425-0001

W Vl I

SAMPLElD LOCA TIONIDESCRIPTION QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-64-009

STA-64-010

Ground LeveVOutside Building/East Side/ Adjacent Old Overhead Railroad Coal Drop-off Truck/Sample OfPipe Insulation And Tar Jacket Cover Debris On Ground

Basement/South SidelWindow/Sample Of Window Glazing

240LF

1,024 LF

16 Windows

I

Tar Amosite Asbestos Chrysotile Asbestos Calcium Silicate Binders

N on-Fibrous

Remove

NOTES:

*Degree OfFriability

1. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

JAMAICA, QUEENS, NEW YORK. 11425-0001

BUILDING 6S - GARAGE

\..hI 0\ I

SAMPLE ill WCATIONIDESCRIPTION QUANTITY· FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-65-001 First Floor/Storage Room Adjacent Firehouse/Sample Of9" x 9" Black Floor Tile

500 SF 1 Chrysotile Asbestos Calcite Quartz Binders

O&M

STA-65-001M First Floor/Storage Room Adjacent Firehouse/Sample Of9" x 9" Black Floor Tile Black Mastic

See Sample

STA-65-001

1 Chrysotite Asbestos Tar

O&M

STA-65-002 First FloorlFirehouse/Hazmat Storage Room/Sample Of 12" x 12" Beige Floor Tile

1,144 SF

Includes Mezzanine Office

1 Calcite Cellulose Fibers Binders

2% Chrysotile Asbestos By

TEM-O&M

STA-65-002M First FloorlFirehouselHazmat Storage Room/Sample Of 12" x 12" Beige Floor Tile Brown Mastic

See Sample

STA-65-002

1 Tar Cellulose Fibers

<1.0% Chrysotile Asbestos ByTEM-O&M

STA-65-003 First FloorlFirehouse/Hazmat Storage Room/Sample Of 12" x 12" Spline Ceiling Tile

1,000 SF 2 Cellulose Fibers ....................... 100 ._-----

STA-65-004 First FloorlFirehouselHazmat Storage RoomlBelow Spline Ceiling/Sample Of Sheetrock Ceiling

1,000 SF 1 Gypsum Cellulose Fibers

O&M

NOTES:

*Degree Of Friability New York State ELAP #11058

1. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

BUILDING 65 - GARAGE

......:J I

SAMPLEID LOCATIONIDESCRIPTION QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-65-005 Mezzanine LeveVStorage Room/Sample Of 12" x 12" White Streaked Floor Tile

960 SF 1 Chrysotile Asbestos ....................Trace Calcite Binders

Negative For Asbestos By

TEM

STA-65-005M Mezzanine LeveVStorage Room/Sample Of 12" x 12" White Streaked Floor Tile Brown Mastic

See Sample

STA-65-005

I Tar Cellulose Fibers

Negative For Asbestos By

TEM

STA-65-006 Mezzanine LeveVPlumbing Shop!Office!

Sample Of 12" x 12" Tan Streaked Floor Tile

575 SF I Calcite Quartz Cellulose Fibers Binders

2% Chrysotile Asbestos By

TEM-O&M

STA-65-006M Mezzanine LeveVPlumbing Shop/Office!

Sample Of 12" x 12" Tan Streaked Floor Tile Brown Mastic

See Sample

STA-65-006

1 Tar Cellulose Fibers

STA-65-007 First FloorlElectric Shop/Bathroom/Sample Of 12" x 12" Light Blue Floor Tile

110 SF I Calcite Quartz Binders

Negative For Asbestos By

TEM

STA-65-007M First Floor!Electric Shop/Bathroom/Sample Of 12" x 12" Light Blue Floor Tile Black Mastic

See Sample

STA-65-007

I Tar....................................... l00 Negative For Asbestos By

TEM

NOTES:

"'Degree Of Friability New York State ELAP #11058

1. No Friability

SAMPLEID

STA-65-008

STA-65-009

STA-65-009M

I

W I

STA-65-010

STA-65-011

STA-65-011M

LOCA TIONIDESCRIPTION

First FloorlPaint Storage Room/Sample Of Pipe Insulation

First Floor/Carpenters' Shop/Office/Sample

Of 12" x 12" Dark Blue Floor Tile

First Floor/Carpenters' Shop/Office/Sample

Of 12" x 12" Dark Blue Floor Tile Black

Mastic

First Floor/Carpenters' Shop/Sample Of Fitting Insulation On Pipe

First Floor/Storage Room/Office/Sample Of

12" x 12" Red And White Floor Tile

First Floor/Storage Room/Office/Sample Of

12" x 12" Red And White Floor Tile Grey

And Black Mastic

850LF

Entire Building

180 SF

See Sample

STA-65-009

80 Fittings Entire Building

300 SF

See Sample

STA-65-011

FRIABILITY

COMPOSITION PERCENT

Chrysotite Asbestos

Cellulose Fibers

Mineral Wool

Chrysotile Asbestos ....................Trace

Calcite

Quartz

Binders

Tar

Cellulose Fibers

Chrysotile Asbestos

Mineral Wool

Cellulose Fibers ........................ to

Binders

Calcite

Quartz

Binders

Tar

Calcite................................... IO

Cellulose Fibers

RECOMMENDATIONS

O&M

7.6% Chrysotile Asbestos ByTEM -O&M

<1.0% Chrysotile Asbestos ByTEM -O&M

O&M

<1.0% Chrysotile Asbestos ByTEM

<1.0% Chrysotile Asbestos ByTEM

NOTES:

*Degree OfFriability New York State ELAP #11058

I. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

,.,..----,....--------,...,,,.-"'-,"'.,..~~~~~~~ 1 Ir:.""""N, ___,.,."..,.,,""'...."'"......~~ ---:i"~~~,.

v:;;

I

SAMPLEID LOCA TIONIDESCRIPTION QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-65-012T First FloorlBathroom/Sample Of 12" x 12" Grey Floor Tile Above 12" x 12" Yellow Floor Tile Above 12" x 12" White Floor Tile

80 SF

And

216 SF

Driver's Room

I Calcite Quartz Binders

O&M

STA-65-012C First Floor/Bathroom/Sample Of 12" x 12" Yellow Floor Tile Above 12" x 12" White Floor Tile Below 12" x 12" Grey Floor Tile

See Sample

STA-65-0 12T

I Calcite Quartz...................................... l0 Cellulose Fibers Binders

O&M

STA-65-012B First FloorlBathroom/Sample Of 12" x 12" White Floor Tile Below 12" x 12" Yellow Floor Tile Below 12" x 12" Grey Floor Tile

See Sample

STA-65-012T

I Calcite Quartz Cellulose Fibers Binders

O&M

STA-65-012M First Floor/Bathroom/Sample Of 12" x 12" Grey Floor Tile Above 12" x 12" Yellow Floor Tile Above 12" x 12" White Floor Tile Black Mastic

See Sample

STA-65-O 12T

1 Chrysotile Asbestos Tar

O&M

NOTES:

"'Degree OfFriability

1. No Friability

2. Low Friability (Difficult, But Possible To Damage By Hand)

BUILDING 85

.l:. o

SAMPLEID WCATlONIDESCRIPTlON QUANTITY FRIABILITY COMPOSITION PERCENT RECOMMENDATIONS

STA-85-001 Basement/Storage Room/Sample Of Pipe Insulation

1,610 LF

Entire Basement

2 Amosite Asbestos Chrysotile Asbestos Calcium Silicate

O&M

STA-85-002 Basement/Storage Room/Sample…