VA STRATTON 100 percent BID SET Part1.pdf
PDF 20 MB Posted
- Attached to
- Y1DA--528-809 NEW EMERGENCY DEPARTMENT ADDITION
- Solicitation number
- 36C24222B0026
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 088000 Glazing-8-18-22.pdf | ||
| 084113 Aluminum Framed Entrances and Storefront8-18-22.pdf | ||
| 36C24222B0026 0006.pdf | ||
| Albany VAMC Geotech Report for New ED.pdf | ||
| RFI 4 VA Response.docx | DOCX document | |
| RFI 3 VA Response.docx | DOCX document | |
| 36C24222B0026 0005.pdf | ||
| Stratton ED_103177_SET.pdf | ||
| RFI 2 VA Response.docx | DOCX document | |
| 36C24222B0026 0004.pdf | ||
| 36C24222B0026 0003.pdf | ||
| Site Visit Sign in.pdf | ||
| RFI 1 VA Response.docx | DOCX document | |
| 36C24222B0026 0002.pdf | ||
| 36C24222B0026 0001.pdf | ||
| VA STRATTON 100 percent BID SET Part 5.pdf | ||
| VA STRATTON 100 percent BID SET Part3.pdf | ||
| VA STRATTON 100 percent BID SET Part2.pdf | ||
| VA STRATTON 100 percent BID SET Part4.pdf | ||
| FAR 52.225-2 Buy American Certification 02.docx | DOCX document | |
| Wage Determination NY20220002 07.08.2022.pdf | ||
| 36C24222B0026_1.docx | DOCX document | |
| VAAR 819 219 77 VA Notice of Limitation on subcontracting 02.docx | DOCX document | |
| VA STRATTON 100_ SPECIFICATIONS.pdf |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VAMC SIGNATURE BLOCK
DIRECTOR OF MEDICAL CENTER - SIGNATURE BLOCK
BUILDING 1
HYMAN
HAYES
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
AREA OF WORK
SITE LOCATION
UP
SMOKING
SHELTER
VESTIBULE
UP
UP
EXISTING
MORGUE
EXISTING
AREAWAY
E X
I S
T I N
G
A R
E A
W A
Y
EXISTING
WAREHOUSE
B40-8
MORGUE
B43-2
ELEVATOR
RM
B41
B42
B36-1
B36-2
B39
PUBLICATIONS
B39B40-1
B40-2
B40-3
MORGUE
B40-6
B40-7
B40-7
OFFICE
B43-3
ELEV.
VEST
B37-1
B37-2
B37
EMPLOYEE
GYM
C51-1
C51-2
ELEV
SW6
STAIR
SW4
STAIR
HYMAN
HAYES
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
Description of Required Infection Control Precautions by Class
During Construction Project Upon Completion of
1. Execute work by methods to minimize raising duct rrom construction operations.
2. Immediately replace a ceiling tile displaced for visual inspection.C l a s
I
1. Provide active means to prevent airborne dust from dispersing into atmosphere.
2. Water mist work surfaces to control dust while cutting.
3. Seal unused doors with duct tape.
4. Block off and seal air vents.
5. Place dust mat at entrance and exit of work area.
6. Remove or isolate HVAC system in areas where work is being performed.
1. Wipe work surfaces with disinfectant.
2. Contain construction waste before transport in tightly covered containers.
3. Wet mop and/or vacuum with HEPA filtered vacuum before leaving work area.
4. Remove isolation of HVAC system in areas where work is being performed.C l a
1. Remove or isolate HVAC system in area where work is being done to prevent contamination of duct system.
2. Complete all critical barriers, i.e., sheetrock, plywood, plastic, to seal area from non-work area or implement control cube method (cart with plastic covering and sealed connection to work site with HEPA vacuum for vacuuming prior to exit) before construction begins.
3. Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.
4. Contain construction waste before transport in tightly covered containers.
5. Cover transport receptacles or carts. Tape covering unless solid lid.
6. All personnel entering work site are required to wear shoe covers. Shoe covers must be changed each time the worker exits the work area.
7. Do not remove barriers from work area until completed project is inspected by the owner's Safety Section and Infection Control Department, and thoroughly cleaned by the owner's Environment Services Department.
1. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
2. Contain construction waste before transportation in tightly covered containers.
3. Cover transport receptacles or carts. Tape covering unless solid lid.
4. Vacuum work area with HEPA filtered vacuums.
5. Wet mop area with disinfectant.
6. Remove isolation of HVAC system in areas where work is being performed.
C l a s s
I V
C l a
I
1. Remove or isolate HVAC system in area where work is being done to prevent contamination of duct system.
2. Complete all critical barriers, i.e., sheetrock, plywood, plastic, to seal area from non-work area or implement control cube method (cart with plastic covering and sealed connection to work site with HEPA vacuum for vacuuming prior to exit) before construction begins.
3. Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.
4. Contain construction waste before transport in tightly covered containers.
5. Cover transport receptacles or carts. Tape covering unless solid lid.
6. All personnel entering work site are required to wear shoe covers. Shoe covers must be changed each time the worker exits the work area.
7. Do not remove barriers from work area until completed project is inspected by the owner's Safety Section and Infection Control Department, and thoroughly cleaned by the owner's Environment Services Department.
1. Do not remove barriers from work area until completed project is inspected by the owner’s Safety Department and Infection Control Department, and thoroughly cleaned by the owner’s Environmental Services Department.
2. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
3. Vacuum work area with HEPA filtered vacuums.
4. Wet mop area with disinfectant.
5. Remove isolation of HVAC system in areas where work is being performed.
NOTES:
PATIENT RISK GROUP FOR "TYPE D" CONSTRUCTION
LOW RISK GROUP
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP
Class IV
Class III / IV
Class IV
Class IV
FIRST FLOOR ICRA PLAN
BASEMENT FLOOR ICRA PLAN
LOW RISK
B-WING
HIGH RISK
B-WING
PAVEMENT DEMOLITION NOTES:
GENERAL NOTES: EROSION & SEDIMENT CONTROL NOTES:
VEHICLE ACCESS NOTES:
TEMPORARY SAFETY BARRIER NOTES:
HYMAN
HAYES
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
EXISTING WAREHOUSE ROOF STRUCTURE -LIMITED ACCESS-
REQUIREMENTS:
ABBREVIATIONS
PHASING PLAN - CONCEPT
PHASE 1: GENERAL START PHASE (6 WEEKS)
PHASE 2: CONTRACTOR MOBILIZATION (3 WEEKS)
PHASE 4: CONSTRUCTION FOR NEW ADDITION (40 WEEKS)
PHASE 3: SITE DEMOLITION (20 WEEKS)
PHASE 5: CONTRACTOR DEMOBILIZATION AND CLOSEOUT (4 WEEKS)
HYMAN
HAYES
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
EXISTING CONDITIONS
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
EROSION AND SEDIMENT CONTROL PLAN
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
DEMOLITION PLAN
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
CONSTRUCTION PLAN
SIDEWALK WITH HANDRAIL DETAIL
SECTION A-A
NOTES:
A
A
SIDE ELEVATION
CONCRETE STAIRS
STAIR HANDRAIL DETAIL
SECTION A-A
NOTES:
A
A
SIDE ELEVATION
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
UTILITIES PLAN
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
GRADING PLAN
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
LIGHTING PLAN
LIGHT POLE DETAIL
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
LIT BOLLARD FOOTING DETAIL
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
LANDSCAPING PLAN
PLANT & TREE SIZES
PLANTING SCHEDULE
PLANTING AND GUYING DETAIL
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
MODEL: MANHOLE-24 SEWER
HEAVY DUTY CAST IRON FRAME & COVER
SANITARY
SEWER
SEWER MANHOLE
TYPICAL INSTALLATION DETAIL
SECTION A-A SECTION B-B
PLAN VIEW
B
B A
A
PRECAST CONCRETE - HEAVY DUTY
4' ID - MANHOLE BASE, RISER AND TOP
TYPICAL TRENCH - SEWER MAIN
PAVEMENT RESTORATION DETAIL
TYPICAL
ASPHALTIC PAVEMENT DETAIL
SEED MIXTURES FOR TEMPORARY STABILIZATION
SPECIES LBS / ACRE
PERMANENT STABILIZATION SEED MIXTURE
SPECIES LBS / ACRE
SPECIES LBS / 1,000 SQFT
LAWN RESTORATION SCHEDULE & NOTES
ASPHALT TESTING NOTES: SANITARY TESTING NOTES:
4" CLEANOUT DETAIL
TOP VIEW
SIDE VIEW
PRECAST CATCH BASIN MODEL CB-30x48
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
CONSTRUCTION SIGN
CHAIN LINK MAN GATE DETAIL
TEMPORARY CONSTRUCTION FENCE:
CHAIN LINK FENCING DETAIL
TEMPORARY CONSTRUCTION FENCE
CHAIN LINK 20' WIDE GATE DETAIL
TEMPORARY CONSTRUCTION FENCE:
NOTES:
PROJECT SAFETY SIGN
NOTES
CONSTRUCTION SPECIFICATIONS:
PERSPECTIVE VIEW
SECTION VIEW
SILT FENCE W/ WIRE REINFORCEMENT DETAIL
STABILIZED CONSTRUCTION DRIVEWAY ENTRANCE DETAIL
TABLE B-1- MAXIMUM ALLOWABLE SLOPES
SOIL OR ROCK TYPE
²
EXCAVATIONS MADE IN LAYERED SOILS
EXCAVATIONS MADE IN TYPE B SOIL
SINGLE BENCH
VERTICAL SIDED LOWER PORTION
SIMPLE SLOPE
MULTIPLE BENCH
SIMPLE SLOPE
VERTICAL SIDED LOWER PORTION
FIGURE B-1.2
EXCAVATIONS MADE IN TYPE C SOIL
FIGURE B-1.3
29CFR 1926 OSHA SUBPART P - APPENDIX B - SLOPING AND BENCHING
FIGURE B-1.4
SLOPE OF EXCAVATIONS DETAIL
MAXIMUM ALLOWABLE SLOPES (H:V)
FOR
EXCAVATION LESS THAN 20 FEET DEEP
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
TRUNCATED DOME TACTILE WARNING STRIP DETAIL
SEDIMENT PROTECTION FOR CATCH BASIN
CONSTRUCTION SPECIFICATIONS
TREE PROTECTION DETAIL
DROP CURB DETAIL
2A
CONCRETE SIDEWALK & CURB DETAIL
HYSECURITY
6705 S. 209 ST. SUITE 101
KENT, WA 98032-2327
TOLL FREE: 1-800-321-9947
PHONE: (253) 867-3700
FAX: (253) 867-3702
www.hysecurity.com
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWING.
3. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS
FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.
4. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY
THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.
5. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 1-GS-901-906
29/04/20221-GS-901-906 REVISION DATE
BARRIER ARM OPERATOR, INDUSTRIAL HYDRAULIC TRAFFIC CONTROL - STRONGARM
INDUSTRIAL / DEPARTMENT OF TRANSPORTATION
SELECT DESIRED MODEL:
STRONGARM 14F
STRONGARM 20
STRONGARM 28
PERSPECTIVE
STRONGARMDOT 28
STRONGARM 36
STRONGARM 14F
HTG 320-2 ST
UP TO 14 FT (4.3 M)
2 SECONDS (OPEN)
3 SECONDS (CLOSE)
STRONGARM™ MODELS
STRONGARM 20
HTG 320-3 ST
UP TO 20 FT (6 M)*
3 SECONDS (OPEN)
4 SECONDS (CLOSE)
STRONGARM 28
HTG 320-6 ST
2,000 CYCLES / DAY
3/4 HP
HYDRAULIC
UP TO 28 FT (8.5 M)*
5 SECONDS (OPEN)
6 SECONDS (CLOSE)
-40 TO 158 F (-40 TO 70 C) NO HEATER NECESSARY
5 YEAR
STRONGARMDOT 28
HTG 320-6 DOT ST
UP TO 28 FT (8.5 M)*
5 SECONDS (OPEN)
6 SECONDS (CLOSE)
STRONGARM 36
HTG 320-8 ST
UP TO 36 FT (11 M)**
ADJUSTABLE
86 +/- 2
8 SECONDS (OPEN)
8 SECONDS (CLOSE)
MODEL
PART #
DUTY CYCLE
HORSEPOWER
DRIVE
ARM LENGTH MAX.
FULL OPEN ANGLE
OPEN/CLOSE TIME
TEMP. RATING
FINISH
WARRANTY
* SIDE MOUNT AVAILABLE FOR ARMS UP TO 18 FT (5.5 M). ARMS 20 FT (6 M) OR LONGER REQUIRE COUNTER WEIGHTS.
**ARMS 30 FT (9 M) OR LONGER REQUIRE CABLE TENSIONER AND ARM STABILIZER AND ADDITIONAL COUNTERWEIGHTS.
ZINC PLATED
WITH YELLOW
POWDER COATING
ZINC PLATED
WITH YELLOW
POWDER COATING
HOT DIPPED
GALVANIZED WITH
STAINLESS STEEL
COVER
TRAFFIC CONTROL ARM DETAIL
TYPICAL SIDEWALK DETAIL
6.
DROP CURB DETAIL "B" FOR
DECONTAMINATION TRAILER PAD
2B
DROP CURB AT CORNER DETAIL
2C
CURB DROP INLET PROTECTION
PLAN VIEW
SECTION A-A
A A
PAVEMENT JOINT DETAIL -
ENTRANCE DRIVE WITH EXISTING ROAD
9.
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
CROSSWALK STRIPING DETAIL
EXPANSION JOINT DETAIL
CONCRETE PAVEMENT
STRAIGHT DIRECTIONAL ARROW
PAVEMENT MARKING DETAIL
CONCRETE PAVEMENT
CONTROL JOINT DETAIL
CONCRETE PAVEMENT TO ASPHALT PAVEMENT
JOINT DETAIL
C C
SECTION C-C
BREAKAWAY STYLE
SIGN POST DETAIL
DO NOT
ENTER
DO NOT ENTER
NO PARKING PATIENT DROP-OFF OR PICK-UP ONLY SIGN
EMERGENCY VEHICLES ONLY SIGN
AMBULANCE ENTRANCE SIGN EI-08.03
CONCRETE PAVEMENT DETAIL
RETAINING WALL FOR PLAZA AREA
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
BOLLARD INSTALLATION WITH TURN DETAIL
TYPICAL BOLLARD ARRAY INSTALLATION DETAIL
BOLLARD INSTALLATION ACROSS GRADE DETAIL
REMOVABLE BOLLARD OPTION DETAIL
10" PAWN DECORATIVE BOLLARD COVER DETAIL
IMPACT RATED BOLLARD DETAIL
CONCRETE PAD DETAIL (DEDUCT ALTERNATE NO.4)
NOTE:
BOLLARD POST DETAIL
UTILITY TUNNEL ACCESS
FLEXIBLE MARKER STAKE
DECONTAMINATION TANK
ASSOCIATES
800 TROY-SCHENECTADY
ROAD, STE 103
LATHAM, NY 12110
(518) 452-3470 www.hymanhayes.com
ENGINEERING LLP
FE PROJECT NO: 19-181
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
528-809
Project Director
MARCH 18, 2022 JDFRevisions: Date:
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT100% FOR BID
SRB
1 1.8 2 2.4
6 7
8 9
11 12 14 15 16 17 18
20 21
R
Q
P
N
M
L
K
J
H.8 H.7
H
G
F
E
D
D.2
G.4
W16X26 W16X26
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W16X36
W16X36
W16X26 W18X40
W16X36
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
W12X26
W12X26 W12X26
W12X26 W12X26
W16X26
W16X26
W12X26
W12X26
W12X26
W12X26 W12X26
W X
W12X26 W12X26
W16X26 W12X26
W16X26
W X
W X
W X
W X
W X
W12X26
W12X26
W16X26
W14X22
W16X26 W16X26
W
X26
W
X26
W
X26
W 12X26
W X
W X
9 W
X
W12X26
W X
W X
W12X26
W X
W12X26
W X
W X
16.1
BF-4
BF-3
BF-2
BF-5
BF-7
BF-8
MASONRY
SHEAR WALLS
W10X19
BF-9 BF-9
JOINT
2"SEISMIC
W10X19
W10X19
W10X19
W10X19
AREA 1 - 3" x 16 GAUGE
GALVANIZED METAL ROOF DECK,
SEE 2/1-SS-301. TYPICAL
CANT
CANT
CANT
CANT
CANT
BF-6
C A
N T
C A
N T
2"SEISMIC JOINT
F.4
W18X40W16X36
BF-13
B F
-1
BF-10
W14
W
10 BL
W
12 BL
W
W
10 BL
10 BL
10 BL
10 BL
10 BL
10 BL
10 BL
W14
W14
W14
10 BL
10 BL
10 BL
10 BL
W
W
10 BL
W
W
W10
W
W
W
W
B
L
W18W18W18
W18 W18 W21 W18
W14
W
W
W8W18 W18 W18
W14
W
W18W18W18
W
10 BL
W
W
10 BL
10 BL
10 BL
B L
W
W
W
W
B
L W
W 0 W
W
W
B
L
10 BL
10 BL
B
L
B
L
B
L
B
L
B
L
W
W
W
B
L
B
L
W
W
W
W
W
W
W
W
W
W
10 BL
10 BL
6 BL
B
L
W12
1-SS-302
1-SS-303
1-SS-302
C A
N T
W X
1-SS-302
1-SS-302
K.5
W10X19
RD
RD
RD
S
55 59 63
86 85
JOINT
2"SEISMIC
1-SS-302
SIM
1-SS-303
/4
/4
EXISTING 4"± REINF CONC
SLAB W/ 2"± TOPPING (TYP
UNO). T/EXIST STL (11'-5"±).
HSS MOMENT
CONNECTION.
SEE 6/1-SS-301
SKEWED FRAMING
CONNECTIONS.
SEE 3/1-SS-301
1'-5 1/2"
1-SS-302
EXTERIOR FACE OF
EXISTING WALL
1-SS-202
1-SS-302
C10X15.3 (11'-8")
C X
.3
(1
C10X15.3 (11'-8")
C10X15.3 (11'-8")
W10X19 (11'-8")
W10X19 (11'-8")
W10X19 (11'-8")
7"SEISMIC JOINT
1-SS-302
W12X26
1-SS-302
SIM
W
H O
IS
T
B E
A M
W
1-SS-302
SIM
1-SS-302
RD
AT BRACE INTERSECTION,
TYPICAL
OPENING JAMB POST, TYP
W10X19 AT BRACE
INTERSECTION
W10X19
F2
F2
F2
F2
F1
F2
BF-1
W10X19 (11'-8") F2
F3
F3 F3 F3 F3 F3
F4
W10X19 W
12X26
W 12X26
W
X19
2'-5 5/8"
L.5
W X
W X
B F
-1
W12X26
CONNECT TO EXISTING BUILDING
COLUMN, TYPICAL 3-LOCATIONS.
3/8" BENT PLATE, ATTACH TO
BEAM T/FLANGE
3/8" BENT PLATE, ATTACH
TO BEAM T/FLANGE
W16X26
W16X26
W16X26
W16X26
W16X26
W16X26
W16X26
W X
W16X26
W18X40
W12X26
W X
W X
W16X26
W16X26
W16X26 W12X26
W12X26
W12X26
W16X26
W16X26
W16X26
W12X26
W12X26
W12X26
W16X26
W12X26
W12X26
W12X26
W X
W18X40
W18X40
W16X26
W12X26
W12X26
W16X26
W16X26
W16X26
W16X26
W16X26
W X
W16X36
W16X26
W16X26
W16X26
W16X26
W X
W X
W X
W X
W X
W X
W X
W X
W X
W X
F4
F
F5
F
F5
W10X19
W10X19
W10X19
W10X19
W10X19
3'-3"
/8
3'-3"2
/2
2'-10"
/2
OPEN TO BELOW
(SEE 2/1-SS-104 FOR
WALK-IN LOBBY HIGH
ROOF FRAMING PLAN)
1 1/2" x 16 GAUGE GALV
METAL ROOF DECK,
SEE 2/1-SS-301 5
1-SS-303
SIM
W10X19
W10X19
W X
C X
.3
W X
W12X26
W X
C10X15.3
C X
.3
W12X26
W X
W12X26
C10X15.3 W10X19
W10X19
W10X19
W10X19
CANT
W10X19
W10X19
C X
.3
W10X19
W10X19
W10X19
W10X19
W X
1-SS-303
SIM
1-SS-303
SIMF
W16X36
W12X26
W X
D.1 CANT
CANT
CANT CANT
CANT
W18X35
W10X19
F3
CANT
W14X34
F.3
19.1
W X
W X
W12X26W16X26
12X26 C
AN
T W
12X26
W
X26
W 10X19
W 10X19
W 10X19
W10X19
W X
W 10X19
W X
W 12X26
W X
W X
X
C A
N T
W X
W X
W 10X19
W 10X19
W 12X26
2"
SE
IS
M
IC
J O
IN
T
W10X19
D.5
D.3
B
A
C
W14X34
W12X26
1-SS-202
1-SS-302
SIM
1"
1-SS-104
1-SS-302
SIM
C A
N T
C A
N T
1-SS-202
1-SS-302
SIM
SEE NOTE 13, TYPICAL
W12X26
W12X26
W12X26
W12X26
W12X26
W12X26
W12X26
W12X26
W12X26
W12X26
W12X26
W12X26
1-SS-302
J O
IN
T
S E
IS
M
IC
W12X26
W16X26
W10X19
W12X26
W X
W X
W X
W12X26
1-SS-302
W12X26
JO
IN
T
2"SE
ISM
IC
J O
IN
T
"S
E
IS
M
IC
J O
IN
T
"S
E
IS
M
IC
W X
1-SS-303
JOINT
2" SEISMIC
W10X19
W10X19
W 12X26
W
X26
W 12X26
W 10X19
W 10X19
1-SS-302
1-SS-301
1-SS-302
1-SS-302
W12X26 W12X26
W X
W X
AHU-ED-1 WEIGHT = 33,000#
NOTIFY ENGINEER IF THIS WEIGHT
IS TO BE EXCEEDED. COORDINATE
EXACT SUPPLEMENTAL FRAMING
LOCATIONS WITH SHOP
DRAWINGS AND UNIT(S) PROVIDED
AHU-ED-2 WEIGHT = 21,000#
NOTIFY ENGINEER IF THIS
WEIGHT IS TO BE EXCEEDED.
COORDINATE EXACT
SUPPLEMENTAL FRAMING
LOCATIONS WITH SHOP
DRAWINGS AND UNIT(S)
PROVIDE
EXHAUST FAN EF-ED-7
WEIGHT = 2,200# NOTIFY
ENGINEER IF THIS WEIGHT
IS TO BE EXCEEDED
RD RD
EXHAUST FAN EF-ED-6
WEIGHT = 2,300# NOTIFY
ENGINEER IF THIS WEIGHT
IS TO BE EXCEEDED
EXHAUST FAN EF-ED-5 WEIGHT = 2,100#
NOTIFY ENGINEER IF THIS WEIGHT IS TO
BE EXCEEDED
W X
W X
W X
W X
W X
W X
W X
W X
W8X10
W8X10 W8X10 W8X10 W8X10 W8X10
W8X10W8X10
W8X10
W8X10W8X10
1-SS-3049
W X
W 10X19
W12X26
1-SS-301
EOD
9 1/2"
F3
1 1/2" x 16 GAUGE GALV
METAL ROOF DECK,
SEE 2/1-SS-301
1 1/2" x 16 GAUGE GALV
METAL ROOF DECK,
SEE 2/1-SS-301
W12X26
W8X10
W X
W X
W8X10
W X
W X
W X
W X
W X
W X
W X
W X
W8X10
W X
W X
EF-ED-1 WEIGHT = 250#
NOTIFY ENGINEER IF THIS
WEIGHT IS TO BE EXCEEDED
EF-ED-2 WEIGHT = 200# NOTIFY ENGINEER
IF THIS WEIGHT IS TO BE EXCEEDED
ACCU-2 WEIGHT = 250# NOTIFY ENGINEER
IF THIS WEIGHT IS TO BE EXCEEDED
ACCU-3 WEIGHT = 250#
NOTIFY ENGINEER IF
THIS WEIGHT IS TO BE
EXCEEDED
ACCU-1 WEIGHT = 250#
NOTIFY ENGINEER IF THIS
WEIGHT IS TO BE EXCEEDED
PREFABRICATED
METAL CANOPY
W X
W18X40
W12X26
W X
W X
W X
W X
2.5
W16X36
W12X26
1-SS-303
W18X40
RD
W12X26
RD
RD
RD
RD
RD
RD
W12X26
CANT
W X
2" SEISMIC JOINT
W10X19
/8
D.8
AREA 2 - 3" x 16 GAUGE
GALVANIZED METAL ROOF
DECK, SEE 2/1-SS-301.
AREA 3 - 3" x 16 GAUGE
GALVANIZED METAL ROOF
DECK, SEE 2/1-SS-301. TYPICAL
AREA 4 - 3" x 16 GAUGE
GALVANIZED METAL ROOF
DECK, SEE 2/1-SS-301.
1-SS-302
1-SS-302
W X
W X
W X
W X
THROUGH PLATE
CONNECTION
THROUGH PLATE
CONNECTION
W X
A=22K
A=76K
A=46K A=35K A=35K A=23K A=23K
A
K A
K A
K A
K A
K A=52KA=52K
A
K A
K
A=14KA=14K
A
K
THROUGH PLATE
EACH OF THESE
CONNECTIONS.
DESIGN FOR A = 90K
THROUGH PLATE
EACH OF THESE
CONNECTIONS.
DESIGN FOR A = 90K
A
K
A
K
A
K
W8X10
W8X10
E Q
E Q
E Q
1-SS-302
1-SS-302
1-SS-302
1-SS-302
1-SS-302
1-SS-302
1-SS-302
W X
W X
1-SS-302
1-SS-302
1-SS-302
PREFABRICATED
METAL CANOPY
NOTES:
1. T/STEEL (B/DECK) ELEVATION (13'-6") WITH RESPECT TO REFERENCE ELEVATION (0'-0")
UNLESS NOTED OTHERWISE.
2. ELEVATIONS NOTED ( ) ARE TO T/STEEL (B/DECK) WITH RESPECT TO ELEVATION (0'-0").
3. EQUALLY SPACE ROOF BEAMS BETWEEN COLUMNS UNLESS NOTED OTHERWISE.
4. BF_- INDICATES STEEL BRACED FRAME. SEE 1-SS-304 FOR SCHEMATICS AND DETAILS.
5. SEE 5/1-SS-301 FOR TYPICAL FRAMING CONNECTIONS TO HSS COLUMNS.
6. EOD INDICATES EDGE OF DECK.
7. SEE 1-SS-001 FOR LINTEL NOTES. NOT ALL LINTELS IN WALLS ARE SHOWN.
8. SEE 3/1-SS-301 FOR TYPICAL SKEWED PLATE SHEAR CONNECTION
9. RD - INDICATES ROOF DRAIN
EF - INDICATES EXHAUST FAN
RV - INDICATES ROOF VENT
COORDINATE SIZE AND LOCATION WITH MECHANICAL AND ARCHITECTURAL DRAWINGS.
PROVIDE ROOF OPENING ANGLE FRAME AT ROOF DRAINS, VENTS, EXHAUST FANS, AND
HATCHES. SEE 1/1-SS-301.
10. NOTIFY ENGINEER IF ACTUAL WEIGHTS OF MECHANICAL UNITS EXCEED WEIGHTS NOTED ON
PLAN. COORDINATE EXACT DIMENSIONS AND LOCATIONS WITH THE MECHANICAL DRAWINGS
AND UNITS SUPPLIED.
11. SEE 1-SS-400 FOR CFMF ELEVATIONS, SECTIONS AND DETAILS.
12. SEE SHEET 1-SS-500 FOR COLUMN SCHEDULE
13. F_ INDICATES BLAST FRAME. SEE 1-SS-400
14. SEE 1-SS-001 FOR ADDITIONAL NOTES.
HYMAN
HAYES
ASSOCIATES
800 Troy-Schenecady Road, Suite 103
Latham, NY, 12110
(518) 452-3470 www.hymanhayes.com
PROJECT
NORTH
KEY PLAN
CORE
WING 'C'
WING 'B' WING 'A'
WING 'D'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A/E:
19-181
C U s e rs \z w e b b e r\ D o c u m e n ts
\V A
E D
S tr u c tu ra l_ z w e b b e r2 g m a il.
c o m .r v t
/2
/2
:0
:5
1-SS-103
ROOF FRAMING PLAN BUILD NEW EMERGENCY
DEPARTMENT
HOLLAND AVENUE, ALBANY, NY
528-809
March 18, 2022 JP ZW
100% FOR BID
20057
SCALE: 1/8" = 1'-0"1-SS-103
1 ROOF FRAMING PLAN
0' 4' 8' 32'16'
Revisions: Date:
CODE
ACCESSORY LEGEND
ITEM MODEL NUMBER
CODE BLUECB SEE SPECS
C CCLOTHING HOOKCH SEE SPECS
DIAPER CHANGING STATIONDCS SEE SPECS
GRAB BARGB SEE SPECS
LIQUID SOAP DISPENSERLSD SEE SPECS
MOP/ BROOM HOLDERMBH SEE SPECS
MIRRORMR SEE SPECS
NURSE CALLNC SEE SPECS
PAPER TOWEL DISPENSERPTD SEE SPECS
SANITARY NAPKIN DISPOSALSND SEE SPECS
TOILET PAPER DISPENSERTTH SEE SPECS
FIRE EXTINGUISHER CABINETFEC SEE SPECS
ACQUISITION CODE
C C
C C
C C
C C
C C
C C
V C
C C
V C
C C
V C
FEC SIGNAGE
H T
TEL/
DATA
TWIST LOCK
RECEPTACLE
RECEPTACLE
'-6
'-0
DOOR
ACTUATOR
LIGHTING
SWITCHES
HUMIDISTAT
THERMOSTAT
ALARM
PANEL
FIRE HOSE
CABINET (FHC)
'-0
'-0
'-0
ZONE VALVE BOXES
Z.V. Z.V.
ELECTRIC PANEL
(E.P.)
'-6
'-0
FIRE EXTINGUISHER
CABINET (FEC)
'-6
'-0
'-1
CH
'-4
SHARPS BOX
PTD
'-2
LSD
'-6
SND
'-3
'-0
HOLDER OUTLET
AND TOP EDGE OF
DISPOSAL
'-9
DIAPER
CHANGING STATION
M A
T C
H
IN
G S
H O
W E
R S
U R
R O
U N
D S
Y S
T E
M T
O B
E
P R
O V
ID
E
D W
IT
H
M A
N U
F A
C T
U R
E R
'S S
H O
W E
B
S E
SHOWER
GB-1
GB-1
FOLD DOWN BENCH
1'-6"
'-6
'-1
"6"
GB-2
'-0
'-6
2'-0"
CURTAIN ROD
(CR-1)
SHOWER CURTAIN
(SC-1)
4" MAX.
SHOWER HEAD ON
ADJUSTABLE SLIDE
SOFFIT
3" LIGHT VALANCE
COUNTERTOP AND
BACKSPLASH AS
INDICATED
SINK & FAUCET - SEE
PLUMBING DRAWINGS
DOOR SWING
WALL BASE
ADJUSTABLE SHELVES ON BRACKETS
STANDARDS
WIREMOLD/ RECEPTACLE - COORDINATE
WITH ELECTRICAL DRAWINGS
WORK SURFACE
FABRIC WRAPPED
TACK PANEL
BACKSPLASH, AS INDICATED
METAL SUPPORT
BRACKET
WALL CABINET
CABINET
MICROWAVE
OPEN
WALL CABINET
WALL SHELVES
ADJUSTABLE
COUNTER/ SINK BASE CABINET
(1) DRAWER
BASE CABINET/ BASE CABINET
(4) DRAWER
BASE CABINET/
W/ BACKSPLASH
WORKSURFACE
NOTE:
CABINET TYPE LEGEND GRAPHICALLY DENOTES MILLWORK TYPES
FOUND IN INTERIOR ELEVATIONS. SEE MILLWORK SECTIONS DRAWING
SHEET FOR CORRESPONDING MILLWORK SECTIONS.
DOOR PULLS
V A
R
IE
S
C O
U N
T E
R H
E
IG
H T
SLOPED TOP
OPEN
U .N
.O
MICROWAVE
SINK APRON
MR
PTD
'-4
1'-3"
'-1
MIN.
8"
LEG CLEARANCE
11"MIN.
CLEARANCE
9"TOE
'-3
LAVATORY
'-1
'-0
MR
LIQUID SOAP
DISPENSER
LSD
CLEAR KNEE SPACE
TYPICAL MOUNTING HEIGHTS AT TOILET
ROOMS UNLESS OTHERWISE NOTED.
1'-6"
3'-6" 1'-0"
'-1
'-9
'-6
39" TO 41"
3'-0" 6"
TOILET - FLOOR MOUNTED
'-5
'-6
7" TO 9"
'-0
NC
GB
GB
TTH
GB
CUT HORIZONTAL
FASTENER FROM STUD
VERTICAL WALL STUDS AT
16" [406MM] OR 24" [610MM]
O.C.
FASTEN AT BOTH
ENDS WITH MIN. 4
TAPPING SCREWS.
WALL FINISH
ISOMETRIC
PLAN
NOTE:
CONTRACTOR SHALL COORDINATE
LOCATIONS OF HORIZONTAL
FASTENERS.
CODE
ABBREVIATIONS LEGEND (NOT ALL ABBREVIATIONS MAY BE USED)
ABBREVIATED TERM
ARCHITECT/ ARCHITECTURALARCH
BOTTOM OFB/
BUILDINGBLDG
BEARINGBRG
BASE PLATEBP
CANTILEVERCANT
CONTROL, CONTRACTION, CONSTRUCTION JOINTCJ
CENTER LINE℄
CONCRETE MASONRY UNIT(S)CMU
APPROXIMATEAPPROX
CONCRETECONC
CONTINUOUSCONT
COLUMNCOL
COLD-FORMED METAL FRAMING CFMF
COORDINATECOORD
DIAMETERØ
DIMENSIONDIM
DOWNDN
DITTOdo
DRAWINGDWG
EACHEA
EXPANSION JOINT EJ
ELECTRICALELEC
ELEVATIONEL
ELEVATOR ELEV
ENGINEERENGR
EMBEDDED EMBD
EQUALEQ
EQUIPMENT EQUIP
EACH SIDE ES
EACH WAY EW
INTERIOR INT
CODE ABBREVIATED TERM
INVERT INV
KIPSK
LONGLG
LONG LEG VERTICAL LLV
LIGHT WEIGHTLW
LOWLO
MANUFACTURERMANUF
MAXIMUMMAX
MECHANICALMECH
MINIMUMMIN
LONG LEG HORIZONTALLLH
MISCELLANEOUSMISC
MASONRY OPENINGMO
NOT APPLICABLENA
VERTICAL VERT
CODE ABBREVIATED TERM
VERIFY IN FIELD VIF
WITHW/
WORK POINT WP
WALL CONTROL OR CONSTRUCTION JOINT WCJ
WELDED WIRE REINFORCEMENT WWR
PRECAST PC
PRESSURE TREATED PT
RADIUSR
ROOF DRAIN RD
REGISTERED DESIGN PROFESSIONAL RDP
REQUIRED REQD
REINFORCING OR REINFORCED REINF
REVISION OR REVISED REV
ROUGH OPENING RO
SIMILAR SIM
STANDARD STD
SQUARE FEETSF
STAINLESS STEEL SS
STEEL STL
SQUARESQ
TOP OFT/
UNLESS NOTED OTHERWISE UNO
EDGE OF SLAB EOS
FLOOR DRAIN FD
FOUNDATION FDN
FOOTING FTG
GAUGEGA
GALVANIZED GALV
HOLLOW STEEL SECTION HSS
HORIZONTAL HORIZ
HIGH POINT HP
HEATING/ VENTILATING/ AIR CONDITIONING HVAC
INFORMATION INFO
GYPSUM WALL BOARD GYP.
POWDER-ACTUATED FASTENER PAF
PROFESSIONAL ENGINEERPE
POUNDS PER LINEAR FOOT PLF
POUNDS PER SQUARE FOOTPSF
POUNDS PER SQUARE INCH PSI
POUNDS PER CUBIC FOOTPCF
EXISTING EXIST
EXPANSION EXP
EXTERIOR EXT
EDGE OF DECK EOD
NOT IN CONTRACTNIC
NOMINALNOM
NORMAL WEIGHTNW
ON CENTEROC
OUTSIDE DIAMETEROD
OPENINGOPNG
OPPOSITEOPP
PLATEPL
HYMAN
HAYES
ASSOCIATES
800 Troy-Schenecady Road, Suite 103
Latham, NY, 12110
(518) 452-3470 www.hymanhayes.com
PROJECT
NORTH
KEY PLAN
CORE
WING 'C'
WING 'B' WING 'A'
WING 'D'
WING 'E'
PROJECT
AREA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A/E:
19-181
C T e m p \R e v it F ile s \2
V A
E D
C e n tr a l_ je re m y d e la b ru e re
.r v t
/1
/2
:3
:2
P
M
1-AS-001
GENERAL NOTES, TYPICAL
ELEVATIONS
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT
HOLLAND AVENUE ALBANY, NY
528-809
March 18, 2022 Checker MM
100% FOR BID
20057
SCALE: 1/2" = 1'-0"1-AS-001
4 TYPICAL MOUNTING HEIGHTS
SCALE: 1/2" = 1'-0"1-AS-001
2 TYPICAL TOILET ROOM MOUNTING HEIGHTS
SCALE: 1/2" = 1'-0"1-AS-001
3 TYPICAL CABINET TYPE LEGEND
SCALE: 1/2" = 1'-0"1-AS-001
1 TOILET ROOM FIXTURE LOCATIONS
GENERAL NOTES
1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE GOVERNMENT CODES INCLUDING BUT NOT LIMITED TO OSHA, ADA
AND NFPA.
2. ALL ENTRANCES SHALL COMPLY WITH THE ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS, OR VA
BARRIER FREE DESIGN STANDARD WHICHEVER IS MORE STRINGENT.
3. CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND NOTIFY THE VA COR OF ANY INACCURACIES.
4. THE CONTRACTOR SHALL HOLD THE VA COR, ARCHITECT AND ENGINEERS HARMLESS AGAINST ANY AND ALL CLAIMS
ARISING FROM WORK PERFORMED BY THE CONTRACTOR ON THE SITE.
5. COMMENCE WORK IMMEDIATELY UPON AWARD OF THE CONTRACT AND PROCEED DILIGENTLY AND CONTINUOUSLY
TO COMPLETION.
6. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO COMPLETE THE WORK.
7. PROVIDE ALL MATERIALS AND PERFORM ALL WORK IN ACCORDANCE WITH RECOGNIZED GOOD STANDARD
PRACTICES.
8. ALL MATERIALS SHALL BE AS SPECIFIED, OR EQUAL AS APPROVED BY DESIGN TEAM. MATERIALS SPECIFIED INDICATE QUALITY INTENT THAT WILL BE USED AS A BASIS FOR REVIEW OF SUBSTITUTES. FINAL APPROVAL OF PRODUCTS AND EQUALS TO BE PROVIDED BY THE ARCHITECT, ENGINEER AND VA COR AS REQUIRED.
9. PROVIDE VA COR WITH TIMELINE SCHEDULE FOR INSTALLATION OF VA COR-PROVIDED, CONTRACTOR- INSTALLED
EQUIPMENT.
10. ALL ITEMS WHICH ARE NOT SPECIFICALLY REFERRED TO ON THESE DRAWINGS ARE TO BE SELECTED BY THE VA COR FROM THE MANUFACTURER'S STANDARD SAMPLES SHOWING FULL RANGE OF TEXTURES AND COLORS AVAILABLE.
11. FOLLOW MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS FOR INSTALLATION OF ALL MATERIALS.
12. THE WORDS "PROVIDE" OR "SUPPLY" SHALL INCLUDE BOTH FURNISHING AND INSTALLING THE SPECIFIED OR
DETAILED ITEM, IN PLACE AND READY FOR OPERATION AND USE.
13. CONTRACTOR SHALL STORE MATERIALS IN AREAS DESIGNATED BY VA COR. DELIVERY OF MATERIALS SHALL BE AS
DIRECTED BYVA COR.
14. ALL DIMENSIONS SHALL BE FIELD VERIFIED. DO NOT SCALE DRAWINGS. INDICATED DIMENSIONS ARE TO CENTERLINE OF STEEL, FACE OF EXISTING GYPSUM BOARD PARTITIONS, FACE OF STUDS AT NEW GYPSUM BOARD
PARTITIONS OR FACE OF CMU.
15. MINOR ITEMS OF WORK SUCH AS CUTTING, BLOCKING, TRIM, ETC. SHALL BE PERFORMED AS REQUIRED TO MAKE THE
WORK COMPLETE WHETHER SHOWN OR NOTED ON THE CONTRACT DOCUMENTS OR NOT.
16. PROTECT FINISHED FLOORS AND OTHER SURFACES WITH DURABLE SHEET MATERIALS FROM TRAFFIC, DIRT, WEAR, DAMAGE OR MOVEMENT OF HEAVY OBJECTS.
17. CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH DURING CONSTRUCTION. LEAVE PROJECT AREA BROOM CLEAN AT THE END OF EACH DAY. REMOVE ALL DEBRIS FROM THE SITE IN ACCORDANCE WITH STATE AND
LOCAL CODES. COORDINATE REMOVAL WITH VA COR.
18. PERFORM FINAL CLEANING AT THE END OF THE CONTRACT. CLEAN INTERIOR SURFACES, EQUIPMENT AND
FIXTURES. REPLACE FILTERS AT MECHANICAL EQUIPMENT.
19. PROVIDE TEMPORARY AND REMOVABLE PROTECTION FOR INSTALLED PRODUCTS. CONTROL ACTIVITY IN IMMEDIATE
WORK AREA TO MINIMIZE DAMAGE.
20. USE SUITABLE METHODS TO LIMIT DUST AND DIRT FROM ADJACENT AREAS. CLEAN ADJACENT SURFACES DIRTIED BY
THE REMOVALS.
ACQUISITION CODE LEGEND:
C C - CONTRACTOR FURNISHED AND INSTALLED
V C - VA FURNISHED, CONTRACTOR INSTALLED
V V - VA FURNISHED AND INSTALLED
N.T.S1-AS-001
5 ANCHORAGE - TYPICAL GRAB BARS AND CABINETS
A08
PARTITION TYPE
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
7/8" x 20 GA FURRING HAT
CHANNEL AT 16" O.C.
EXISTING WALL ASSEMBLY
SCALE: 1" = 1'-0"
1 1/2"
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
3 1/2" ACOUSTICAL BATT
INSULATION
3 5/8" 20 GA AT 16" O.C.
STEEL STUD FRAMING
J08
PARTITION TYPE
SCALE: 1" = 1'-0"
4 1/4"
5/8" TYPE "X" GYPSUM
WALLBOARD, EACH SIDE
3 5/8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
3 1/2" ACOUSTICAL
BATT INSULATION
J18
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
4 7/8"
5/8" TYPE "X" GYPSUM
WALLBOARD, EACH SIDE
6" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
5 1/2" ACOUSTICAL
BATT INSULATION
L18
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
7 1/4"
1" GYP. WALLBOARD
LINER, ONE SIDE
2 1/2" C-H STUD x 20 GA. AT 24"
O.C. STEEL STUD FRAMING
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
R25
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 43 UL DESIGN No. U415
(1 HR. RATING ASSEMBLY)
3 1/8"
MASONRY JOINT
REINFORCEMENT
D04
PARTITION TYPE
SCALE: 1" = 1'-0"
8" (NOMINAL) CONCRETE
MASONRY UNIT
UL DESIGN No. U905
(WHERE 1 HR / 2 HR.
RATING NOTED)
10 5/8"
LOOSE MASONRY FILL
INSULATION (AS INDICATED)
1 1/2" RIGID INSULATION
7/8" FURRING CHANNEL
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
3 5/8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
(2) LAYERS 5/8" TYPE "X"
GYPSUM WALLBOARD, EACH
SIDE - STAGGER JOINTS
3 1/2" ACOUSTICAL
BATT INSULATION
J14
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 56 UL DESIGN No. U411 (WHERE 2 HR.
RATING NOTED)
6 1/8"
(2) LAYERS 5/8" TYPE "X"
GYPSUM WALLBOARD,
EACH SIDE
3 1/2" ACOUSTICAL BATT
INSULATION
3 5/8" 20 GA AT 16" O.C.
STEEL STUD FRAMING
J09
PARTITION TYPE
SCALE: 1" = 1'-0"
4 7/8"
MASONRY JOINT
REINFORCEMENT
E04
PARTITION TYPE
SCALE: 1" = 1'-0"
4" (NOMINAL) CONCRETE
MASONRY UNIT
UL DESIGN No. U905
(WHERE 1 HR / 2 HR.
RATING NOTED)
3 5/8"
LOOSE MASONRY FILL
INSULATION (AS INDICATED)
5/8" TYPE "X" GYPSUM
WALLBOARD, EACH SIDE
3 5/8" x 20 GA. AT 16" O.C.
STEEL STUD FRAMING
(1) LAYER 1/2" IMPACT-
RESISTANT GYPSUM
WALLBOARD
J16
PARTITION TYPE
SCALE: 1" = 1'-0"
3 1/2" ACOUSTICAL BATT
INSULATION
1/2" RESILIENT CHANNEL
6"
NOTE:
PROVIDE CONTINUOUS BEAD OF ACOUSTICAL
SEALANT AROUND PERIMETER OF WALL
3 5/8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
3 1/2" ACOUSTICAL
BATT INSULATION
J36
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
4 7/8"
5/8" CEMENT BACKER BOARD TO TOP
OF TILE, 5/8" TYPE "X" GYPSUM
WALLBOARD ABOVE, BOTH SIDES
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
3 5/8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
3 1/2" ACOUSTICAL
BATT INSULATION
J40
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
4 7/8"
5/8" LEAD LINED TYPE "X" GYPSUM
WALLBOARD (1/16" THICK LEAD) UP
TO 7'-0" AFF , ONE SIDE
NOTE: THICKNESS AND EXTENT OF LEAD
SHIELDING TO BE CONFIRMED WITH SITE
SPECIFIC EQUIPMENT AND PHYSICIST REPORT
G30
PARTITION TYPE
2 1/2" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
2 1/2" ACOUSTICAL
BATT INSULATION
SCALE: 1" = 1'-0"
3 1/8"
5/8" CEMENT BACKER BOARD TO TOP
OF TILE, 5/8" TYPE "X" GYPSUM
WALLBOARD ABOVE
3 5/8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
5/8" CEMENT BACKER BOARD TO TOP
OF TILE, 5/8" TYPE "X" GYPSUM
WALLBOARD ABOVE, ONE SIDE
3 1/2" ACOUSTICAL
BATT INSULATION
J34
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
4 7/8"
5/8" CEMENT BACKER BOARD TO TOP
OF TILE, 5/8" TYPE "X" GYPSUM
WALLBOARD ABOVE, ONE SIDE
3 5/8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
3 1/2" ACOUSTICAL
BATT INSULATION
J43
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
4 7/8"
5/8" LEAD LINED TYPE "X"
GYPSUM WALLBOARD (X"
THICK LEAD), ONE SIDE
6" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
5 1/2" ACOUSTICAL
BATT INSULATION
L34
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
7 1/4"
5/8" CEMENT BACKER BOARD TO TOP
OF TILE, 5/8" TYPE "X" GYPSUM
WALLBOARD ABOVE, ONE SIDE
6" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
5 1/2" ACOUSTICAL
BATT INSULATION
L36
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
7 1/4"
5/8" CEMENT BACKER BOARD TO TOP
OF TILE, 5/8" TYPE "X" GYPSUM
WALLBOARD ABOVE, BOTH SIDES
5/8" LEAD LINED TYPE "X" GYPSUM
WALLBOARD (1/16" THICK LEAD)
UP TO 7'-0" AFF, ONE SIDE
3 5/8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
3 1/2" ACOUSTICAL
BATT INSULATION
J41
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
NOTE: THICKNESS AND EXTENT OF LEAD
SHIELDING TO BE CONFIRMED WITH SITE
SPECIFIC EQUIPMENT AND PHYSICIST REPORT
PARTITION TYPE SYMBOLS
--S
PARTITION TYPE
HOURLY FIRE RATING: PARTITION EXTENDS
TO BOTTOM OF STRUCTURE ABOVE.
PARTITION TYPE
PARTITION EXTENDS TO DECK ABOVE
AND SEALED WITH SAFING.
FRAMING EXTENDS TO BOTTOM OF
STRUCTURE ABOVE.
PARTITION TYPE
FINISHES ONE SIDE EXTEND TO 6" ABOVE
HIGHEST ADJACENT CEILING. FINISHES
ONE SIDE EXTEND TO BOTTOM OF
STRUCTURE ABOVE.
PARTITION FRAMING EXTENDS TO
STRUCTURE ABOVE. GYPSUM WALL BOARD
TERMINATES 6" ABOVE HIGHEST ADJACENT
CEILING.
PARTITION TYPE
SUFFIX "S" INDICATES SMOKE PARTITION -
SEAL ONE SIDE TO DECK AND AROUND
ALL PENETRATIONS.
INFILL OPENING. MATCH WALL THICKNESS
AND ALIGN WITH EXISTING WALL.
INFILL
PARTIAL HEIGHT WALL TO UNDERSIDE OF
COUNTER UNLESS OTHERWISE NOTED.
PART
--S SUFFIX "S" INDICATES SMOKE PARTITION -
SEAL TO DECK AND AROUND ALL
PENETRATIONS.
1. THE PARTITION TYPE SYMBOLS WILL KEY THE PARTITION TYPES ON PLANS.
2. ANY PENETRATION THROUGH HOURLY RATED PARTITIONS SHALL BE
FIRESTOPPED WITH MATERIALS TO EQUAL THE HOURLY RATING OF THE
PARTITION SYSTEM IN ACCORDANCE WITH THE SPECIFICATIONS. EXISTING WALLS
WITH NEW PENETRATIONS ARE TO BE SEALED AS REQUIRED TO MAINTAIN
RATING.
3. ALL NEW PARTITIONS TO BE UNLESS OTHERWISE NOTED.
COORDINATE WITH PARTITION TYPE SCHEDULE.
4. ALL CHASES AND DUCT/ PIPE/ COLUMN ENCLOSURES TO BE UNLESS
OTHERWISE NOTED.
5. SEE ROOM FINISH SCHEDULE & INTERIOR ELEVATIONS FOR TILE LOCATIONS AND
HEIGHTS.
6. PROVIDE TYPE "X" MMMR GYPSUM WALLBOARD IN LIEU OF STANDARD TYPE "X"
GYPSUM WALLBOARD AT THE FOLLOWING LOCATIONS, UNLESS NOTED
OTHERWISE ON PLANS AND SECTIONS:
- TOILET AND SHOWER ROOMS
- BASEMENT SPACES AND OTHER BELOW GRADE AREAS
- INSIDE FACE OF EXTERIOR WALLS.
PARTITION TYPE NOTES
J18
J08
G08
PARTITION TYPE
2 1/2" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
2 1/2" ACOUSTICAL
BATT INSULATION
SCALE: 1" = 1'-0"
3 1/8"
3 1/2" ACOUSTICAL BATT
INSULATION
3 5/8" 20 GA AT 16" O.C.
STEEL STUD FRAMING
J30
PARTITION TYPE
SCALE: 1" = 1'-0"
4 1/4"
5/8" CEMENT BACKER BOARD TO TOP
OF TILE, 5/8" TYPE "X" GYPSUM
WALLBOARD ABOVE, ONE SIDE 5/8" TYPE "X" GYPSUM
WALLBOARD, ONE SIDE
3 5/8" x 20 GA. AT 16" O.C.
STEEL STUD FRAMING
(1) LAYER 1/2" IMPACT-RESISTANT
GYPSUM WALLBOARD
J39
PARTITION TYPE
SCALE: 1" = 1'-0"
3 1/2" ACOUSTICAL BATT
INSULATION
1/2" RESILIENT CHANNEL
6"
NOTE:
PROVIDE CONTINUOUS BEAD OF ACOUSTICAL
SEALANT AROUND PERIMETER OF WALL
5/8" TYPE "X" CEMENT BACKER
BOARD TO TOP OF TILE, ONE SIDE
5/8" TYPE "X" GYPSUM
WALLBOARD, EACH SIDE
8" x 20 GA AT 16" O.C.
STEEL STUD FRAMING
5 1/2" ACOUSTICAL
BATT INSULATION
M18
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 49 UL DESIGN No. U465
(WHERE 1 HR.
RATING NOTED)
9 1/4"
8" x 20 GA AT 16" O.C. STEEL
STUD FRAMING
(2) LAYERS 5/8" TYPE "X"
GYPSUM WALLBOARD, EACH
SIDE - STAGGER JOINTS
5 1/2" ACOUSTICAL
BATT INSULATION
M14
PARTITION TYPE
SCALE: 1" = 1'-0"
STC 56 UL DESIGN No. U411
(WHERE 2 HR.
RATING NOTED)
10 1/2"
HYMAN
HAYES
ASSOCIATES
800 Troy-Schenecady Road, Suite 103
Latham, NY, 12110
(518) 452-3470 www.hymanhayes.com
PROJECT
NORTH
KEY PLAN
CORE
WING 'C'
WING 'B' WING 'A'
WING 'D'
WING 'E'
PROJECT
AREA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A/E:
19-181
C T e m p \R e v it F ile s \2
V A
E D
C e n tr a l_ je re m y d e la b ru e re
.r v t
/1
/2
:3
:2
P
M
1-AS-002
PARTITION TYPES STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT
HOLLAND AVENUE ALBANY, NY
528-809
March 18, 2022 Checker MM
100% FOR BID
20057Revisions: Date:
UP
UP
B40-8
MORGUE
B43-2
ELEVATOR
RM
B41
B43-3
ELEV.
VEST
B42
B36-1
B36-2
B39
PUBLICATIONS
B39B40-1B40-2 B40-3
MORGUE
B40-6
B40-7
B40-7
OFFICE
B37-1
B37-2
EXISTING UTILITY TUNNEL
EXISTING AREAWAY
SW6
STAIR
ELEV
B44
CANTEEN
C51-2 C51-1
SW5
STAIR
SW4
STAIR
120'-6" MAX TRAVEL
REM
O
TENESS
O F E
XIT
S 8
1'
M
AX D
IA
G
O
NAL
6'
C O
M M
O N
P A
T H
EXISTING
WAREHOUSE
B37
EMPLOYEE
GYM
NOTE: CONTRACTOR MUST MAINTAIN A
CLEAR EGRESS PATH TO SW5 AT ALL TIMES.
BASEMENT
IT
E004
BIOMED
E005
STORAGE
E001
PASSAGEWAY
B001
MECH.
B43-4
C-WING
HEALTHCARE
OCCUPANCY
HEALTHCARE
OCCUPANCY
B-WING
HEALTHCARE
OCCUPANCY
LIFE SAFETY LEGEND:
SMOKE BARRIER - 1 HR FIRE RATED
EXIT SIGN (E-EXISTING)
EXISTING AREA TO REMAIN
(NOT IN CONTRACT)
EXIT
FIRE EXTINGUISHER CABINETFEC
SMOKE PARTITION - 0 HR FIRE RATED
(LIMIT TRANSFER OF SMOKE)
1 HR FIRE RATED BARRIER (45 MINUTE
DOOR)
2 HR FIRE RATED BARRIER (1 1/2 HR
DOOR AND FIRE DAMPERS)
CORRIDOR WALL - SMOKE PARTITION - 0 HR
FIRE RATED (LIMIT TRANSFER OF SMOKE)
LIFE SAFETY SCHEDULE - BASEMENT (FULL BUILD OUT)
MAX. TRAVEL
DISTANCE
OCCUPANCY
CONSTRUCTION
TYPE
NEW HEALTHCARE
CHAPTER 18
ACTUAL / REMARKS
(IF APPLICABLE)2021
CODE NFPA 101
I (332)
TABLE 18.1.6.1
MINIMUM
CORRIDOR WIDTH
REQ'D # EXITS
200'
18.2.6.2.2
120'-6" (COMPLIES)
30'
18.2.5.3
4'-0" (COMPLIES)
3'-8" STAFF AREAS
18.2.3.4
VARIES: 4'-4" MIN
(COMPLIES)
2 REQ'D
7.4.1.1
2 EXITS
(COMPLIES)
MAXIMUM DEAD
END CORRIDOR
FGI GUIDELINES
6'-0" (PUBLIC W/
STRETCHER)
5'-0" (PATIENT AREAS)
3'-8" (STAFF)
8'-0" (SEMI-RESTRICTED
O.R.)
3.7-7.2.2.1/3.1-7.2.2.1
PROJECT/BUILDING INFORMATION
BUILDING IS FULLY SPRINKLERED
PROJECT IS LOCATED AT THE FIRST FLOOR & BASEMENT
REMOTENESS OF
EXITS
NOT LESS THAN 1/3 MAX
DISTANCE (186'/ 3 = 62')
7.5.1.4
-- 81'-0" (COMPLIES)
I (332)
REQUIRED EGRESS
WIDTH (STAIRS)
.3" / OCCUPANT=39"
TABLE 7.3.3.1
44" (COMPLIES)
REQUIRED STAIR
DIMENSIONS (NEW)
WIDTH (MIN.)
LANDINGS
RISERS
TREADS
HEAD HEIGHT
MAX HT BETWEEN
LANDINGS
COMPLIES
OCCUPANT LOAD 1 OCCUPANT/500 SF
TABLE 7.3.1.2
23 OCCUPANTS
RATING-STORAGE 100
SF OR GREATER
RATING-SOILED
MAXIMUM SMOKE
COMPARTMENT
TRAVEL DISTANCE
MAXIMUM SMOKE
COMPARTMENT
PROJECT SQUARE FOOTAGE, FIRST FLOOR: ADDITION = 11,145 SF, RENOVATION = 260 SF
REQUIRED EGRESS
WIDTH (PROJECT
CORRIDOR)
.2" / OCCUPANT=26"
(36" MIN)
TABLE 7.3.3.1
-- (COMPLIES)
NO RATING REQUIRED
LIMIT THE TRANSFER OF
SMOKE
18.3.6.2.2
SMOKE LIMITING
PARTITION
2-HR2 HR-4 STORIES & MORE
7.1.3.2.1 (3)
RATINGS -
CORRIDORS
RATINGS -
STAIRS
2-HR
(FLOOR)
1 HR-3 STORIES & LESS
BUT NO LESS THAN FLOOR
RATING
8.6.5
RATINGS -
SHAFTS
22,500 GSF
18.3.7.1(3)
N/A--
200' 18.3.7.1(5)
N/A--
1-HR
18.3.2.1.2 (5)
N/A--
1-HR
18.3.2.1.2 (7)
N/A--
FGI (2018)
N/A
TABLE 7.2.2.2.1.1 (a)
COMMON PATH
OF TRAVEL
100' 18.2.5.2
60' - 6" (COMPLIES)
44" TABLE 7.2.2.2.1.2 (B)
44" 7.2.2.3.2.3
7" MAX
11" MIN
6' - 8" MIN
12'-0"
MAXIMUM PROBABLE
OCCUPANTS
EXT. BEARING WALLS: 3 HRS
COLUMNS & BEAMS: 3 HRS
(2 IF SUPPORTING ONLY 1
FLR/ ROOF)
FLOOR-CEILING: 2 HRS
ROOF-CEILING: 1.5 HOURS
HYMAN
HAYES
ASSOCIATES
800 Troy-Schenecady Road, Suite 103
Latham, NY, 12110
(518) 452-3470 www.hymanhayes.com
PROJECT
NORTH
KEY PLAN
CORE
WING 'C'
WING 'B' WING 'A'
WING 'D'
WING 'E'
PROJECT
AREA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A/E:
19-181
C T e m p \R e v it F ile s \2
V A
E D
C e n tr a l_ je re m y d e la b ru e re
.r v t
/1
/2
:3
:5
P
M
1-LS-100
BASEMENT LIFE SAFETY PLAN AND
SCHEDULE
STRATTON VA MEDICAL CENTER
NEW EMERGENCY DEPARTMENT
HOLLAND AVENUE ALBANY, NY
528-809
Approver
March 18, 2022 MH JD
100% FOR BID
20057
SCALE: 1/8" = 1'-0"1-LS-100
1 BASE BID - BASEMENT LIFE SAFETY PLAN
UP
LIFE SAFETY LEGEND:
SMOKE BARRIER - 1 HR FIRE RATED
EXIT SIGN (E-EXISTING)
EXISTING AREA TO REMAIN
(NOT IN CONTRACT)
EXIT
FIRE EXTINGUISHER CABINETFEC
SMOKE PARTITION - 0 HR FIRE RATED
(LIMIT TRANSFER OF SMOKE)
1 HR FIRE RATED BARRIER (45 MINUTE
DOOR)
2 HR FIRE RATED BARRIER (1 1/2 HR
DOOR AND FIRE DAMPERS)
CORRIDOR WALL - SMOKE PARTITION - 0 HR
FIRE RATED (LIMIT TRANSFER OF SMOKE)
LIFE SAFETY SCHEDULE - BASEMENT ALTERNATE
MAX. TRAVEL
DISTANCE
OCCUPANCY
CONSTRUCTION
TYPE
NEW HEALTHCARE
CHAPTER 18
ACTUAL / REMARKS
(IF APPLICABLE)2021
CODE NFPA 101
I (332)
TABLE 18.1.6.1
MINIMUM
CORRIDOR WIDTH
REQ'D # EXITS
200'
18.2.6.2.2
60'-8"' (COMPLIES)
30'
18.2.5.3
4'-0" (COMPLIES)
3'-8" STAFF AREAS
18.2.3.4
VARIES: 4'-4" MIN
(COMPLIES)
1 REQ'D
7.4.1.1
1 EXIT
(COMPLIES)
MAXIMUM DEAD
END CORRIDOR
FGI GUIDELINES
6'-0" (PUBLIC W/
STRETCHER)
5'-0" (PATIENT AREAS)
3'-8" (STAFF)
8'-0" (SEMI-RESTRICTED
O.R.)
3.7-7.2.2.1/3.1-7.2.2.1
PROJECT/BUILDING INFORMATION
BUILDING IS FULLY SPRINKLERED
PROJECT IS LOCATED AT THE FIRST FLOOR & BASEMENT
REMOTENESS OF
EXITS
NOT LESS THAN 1/3 MAX
DISTANCE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .