Stratton ED_103177_SET.pdf
PDF 819 KB Posted
- Attached to
- Y1DA--528-809 NEW EMERGENCY DEPARTMENT ADDITION
- Solicitation number
- 36C24222B0026
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 088000 Glazing-8-18-22.pdf | ||
| 084113 Aluminum Framed Entrances and Storefront8-18-22.pdf | ||
| 36C24222B0026 0006.pdf | ||
| Albany VAMC Geotech Report for New ED.pdf | ||
| RFI 4 VA Response.docx | DOCX document | |
| RFI 3 VA Response.docx | DOCX document | |
| 36C24222B0026 0005.pdf | ||
| RFI 2 VA Response.docx | DOCX document | |
| 36C24222B0026 0004.pdf | ||
| 36C24222B0026 0003.pdf | ||
| Site Visit Sign in.pdf | ||
| RFI 1 VA Response.docx | DOCX document | |
| 36C24222B0026 0002.pdf | ||
| 36C24222B0026 0001.pdf | ||
| VA STRATTON 100 percent BID SET Part 5.pdf | ||
| VA STRATTON 100 percent BID SET Part1.pdf | ||
| VA STRATTON 100 percent BID SET Part3.pdf | ||
| VA STRATTON 100 percent BID SET Part2.pdf | ||
| VA STRATTON 100 percent BID SET Part4.pdf | ||
| FAR 52.225-2 Buy American Certification 02.docx | DOCX document | |
| Wage Determination NY20220002 07.08.2022.pdf | ||
| 36C24222B0026_1.docx | DOCX document | |
| VAAR 819 219 77 VA Notice of Limitation on subcontracting 02.docx | DOCX document | |
| VA STRATTON 100_ SPECIFICATIONS.pdf |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
SIGNOFF / APPROVAL NOTES
1. The facility structure capacity must be able to support the load specified on the installation drawing.
2. Electrical power source provided by the facility, position to be verified in the field.
3. Guldmann Inc. reserves the right to slightly modify the track layout if necessary without Facility approval.
This includes lowering the system to avoid ceiling objects.
4. Guldmann Inc. will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process of which we have not been advised.
5. Modifications of door headers by the facility.
6. Signed drawings are required prior to ordering and installation of ceiling lifts.
This signature of each drawing confirms agreement of all the conditions listed above.
7. Systems are tested at 1.5 times capacity.
550 lbs. tested at 825 lbs.; 770 lbs. tested at 1155 lbs.; 825 lbs. tested at 1238 lbs.; 1100 lbs. tested at 1650 lbs.
MY SIGNATURE BELOW VERIFIES THAT I HAVE:
Reviewed all _____ pages, with a total quantity of _____ room(s), _____ system(s) for the approbation of layout for each room and the approbation of structure for each room.
CUSTOMER
APPROVAL: _____________________________________ DATE: _______________
DATE: DRAWN BY:
ACCURATE TO 4" BASED
ON PDF CONVERSION
Albany Stratton VAMC Stratton ED
113 Holland Ave Albany NY, 12208
PROJECT ID:103177
Stratton ED
FACILITY SIGNOFF
GUL101
KCA07/26/2022
16 16 17
HOIST = 770 LBS, 1100 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 8' - 11", 9' - 0", 9' - 6''3.
ATTACHMENT TYPE = I-BEAM4.
ALL BUILD TO 1100 LBS
SPAN = 5' - 0"
ADJUST END STOPS TO AVOID BOOM5.
AFF TO DECK = 14' - 0''
Revision Schedule
Date Issued by Letter Description
EACH FIXED RAIL TO
HAVE x1 PARALLEL & x2 PERPENDICULAR
STABILIZERS
ALL JOINTS MUST HAVE x1 PARALLEL & x1
PERPENDICULAR STABILIZER
SEE SPAN CHART
S E
E S
P A
N C
H A
R T
SEE SPAN CHART
± 22°
STABILIZERS CAN BE ROTATED 180°
Fixed rail systems Fixed rail systems must be connected by Guldmann Service Team or by a qualified installer.
A Guldmann class I transformer must be used.
Installation to follow existing rules for authorized electricians and according to IEC/UL 60601-1.
Terminals on transformers Class I Double-insulated UL approved cable must be used (Cable specification: UL category: AVLV2, min.300V, min.
80° C, min. 18AWG (1 mm2 )) Transformer DK-13991 In:
Terminal 1 = N Terminal 2 = 100-115V AC Terminal 3 = 230V AC Terminal 4 = Protective ground Out:
Terminal 5 = 33V AC Terminal 6 = 33V AC
POWER TO BE WITHIN 15 FT OF END OF FIXED RAIL
Guldmann permanent mounted ceiling aluminium rail
Hoist with trolleys movable in rail
Protective Plast Enclosure
UL approved 400V cable, green, min. 14 AWG
Protective Ground
M1
UL approved 400V double isolated cable, min. 18 AWG
ON/OFF
UL approved 400V double isolated cable, min. 18 AWG
T ra n s fo rm e r
D K
-1
Main power Permanent installation Specification of breaker:
≥ 2.5 Amp capacity Line must always be broken
L1
AC/DC charger
Main Motor Control
Emergency Stop
Safety Circuit Emergency down
Motor Function Selector Switch0 1
V A
C
U S
V
A C
P ro te c tiv e G ro u nd
V A
C
V A
C1 A
T
.5
A T
Green Light ON (or ON / OFF - sign)
Licensed Electrician to perform hardwire to transformer
MAX
PROJECTION
MAX DISTANCE BETWEEN VERTICAL SUPPORTS
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
X
X
X
RAIL
RAIL
RAIL
RAIL
RAIL
RAIL
INCH
METER
,23
,7
1,2
39 49 59 68 78 118 137 147 157 177 187 206 215 236 246 264
1,0 1,25 1,5 1,75 2,0 3,0 3,5 3,75 4,0 4,5 4,75 5,25 5,5 6,0 6,25 6,75
MAX. 175 KG (385 LBS.)
MAX. 205 KG (450 LBS.)
MAX. 255 KG (560 LBS.)
MAX. 300 KG (660 LBS.)
MAX. 350 KG (770 LBS.)
MAX. 375 KG (825 LBS.)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A-RAIL
WEIGHT: 2.6 KG/M
(1.75 LBS/FT)
B-RAIL
WEIGHT: 5.0 KG/M
(3.36 LBS/FT)
C-RAIL
WEIGHT: 6.0 KG/M
(4.03 LBS/FT)
(2 1/2")
62 mm.
(2
/4
,5 m m
(2 1/2")
62 mm.
(5 m m
(2 1/2")
62 mm.
(6
/3 m m
A
B
C
RAIL MAX. 400 KG (880 LBS.)
X
X
X
A
B
C
RAIL MAX. 500 KG (1100 LBS.)
X
X
X
7,25
8,0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A
B
C
D
E
F
G
H
I
J
K
Ceiling bracket standard
A / B / C
Basic High M
Basic High M
Dimensions
205 mm
580 mm
345 mm
24 mm
58.5 / 125 / 170 mm
156 mm
184 mm
425 mm
2500 mm
970 mm
340 mm
8"
22.8"
13.5"
1.5"
2.2 / 4.9 / 6.6"
6.29"
7.2"
16.75"
98"
38"
13.3"
H
A
E D
F
C
G I
B
K J
SPRING PLATE
AVAILABLE FOR A & B RAIL
FLUSH CEILING PROFILE LIP IS 7/16" X 3/8"
CUT 12 - 15 MM OF THE 2 LONGITUDE
SCREW FOR
PROFILE END
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
Stratton ED
GEN. INFO
GUL102
KCA07/26/2022
PROJECT ID:103177
NTS
BRACING + SUPPORT
NTS
GH3 TRANSFORMER
HOIST = 770 LBS, 1100 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 8' - 11", 9' - 0", 9' - 6''3.
ATTACHMENT TYPE = I-BEAM4.
NTS
RAIL SPAN CHART
NTS
GH3 PATIENT SLING DIMS
NTS
FLUSH CEILING PROFILE
ALL BUILD TO 1100 LBS
SPAN = 5' - 0"
Revision Schedule
Date Issued by Number
ADJUST END STOPS TO AVOID BOOM5.
AFF TO DECK = 14' - 0''
DRAWINGS APPROVED FOR THE GULDMANN
GH-3 LIFTER SYSTEM STANDARD INSTALLATION
OF SUPPORT AND CONNECTION TO I - BEAM.
SYSTEMS INSTALLED FOR 1100 POUNDS WILL BE
TESTED AT 1650 POUNDS.
SYSTEMS INSTALLED FOR 770 POUNDS WILL BE
TESTED AT 1155 POUNDS.
SYSTEMS INSTALLED FOR 550 POUNDS WILL BE
TESTED AT 825 POUNDS.
I - BEAM
TAG ITEM NUMBER DESCRIPTION
10 113024 3/8" NYLOCK NUT
6,7,12
A
GULDMANN RAIL
M A
X
V A
R
IE
S
1 556241 2-7/16' X 10' BACK/BACK PG SOLID
2 HTHR037 12B7 3/8" B7 THREADED ROD
3 550439 STABILIZER BRACKET KIT - GULDMANN
4 550481-US 1" Ø-6013-T6 AL TUBE - GULDMANN
5 550435 CEILING BRACKET KIT - GULDMANN
6 377882 MQM-F WINGNUT 3/8"
7 411764 3/8" X 1-1/4" HEX BOLT
8 11101273 3/8" X 1-1/4" X 1/8" WASHER (THICK)
9 P2787 8-1/4" Beam Clamp
90º
0º
HVAC / MECH
BASEPLATE x4
STABILIZERS x3
STABILIZERS
± 22°
BRIDGE SECTION
BRIDGE / RAIL TOP
8,10
11 411752 3/8" HEX NUT
SPAN
EXISTING I-BEAM
12 370632 MQZ-L BASEPLATE 3/8"
13 377885 MQA-F SADDLE NUT 3/8"
OPTIONAL A
DETAIL A
(OPTIONAL)
40° T O 90°
B
DETAIL B
ALTERNATE STABILIZER CONNECTION
STABILIZER
P1000T
I-BEAM
P2785
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Stratton ED
ATTACHMENT
GUL103
KCA07/26/2022
PROJECT ID:103177
HOIST = 770 LBS, 1100 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 8' - 11", 9' - 0", 9' - 6''3.
ATTACHMENT TYPE = I-BEAM4.
ALL BUILD TO 1100 LBS
SPAN = 5' - 0"
Revision Schedule
Date Issued by Number
AFF TO DECK = 14' - 0''
/8
H O
IS
T
/2
T R
A V
E R
S E
C E
IL
IN
G
GUL104
8'' MIN
/8
/2
/8
27" MAX
20" MIN
27" MAX
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Stratton ED
PROJECT DETAILS
GUL104
KCA07/26/2022
PROJECT ID:103177
HOIST = 770 LBS, 1100 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 8' - 11", 9' - 0", 9' - 6''3.
ATTACHMENT TYPE = I-BEAM4.
Revision Schedule
Date Issued by Number
1" = 1'-0"
ELEVATION - TYPE G
1 1/2" = 1'-0"
CEILING DETAIL - TYPE G
ALL BUILD TO 1100 LBS
SPAN = 5' - 0"
ADJUST END STOPS TO AVOID BOOM5.
AFF TO DECK = 14' - 0''
3/4" = 1'-0"
CEILING - 1100 LBS TWIN HOIST
E105
GUL104
9' - 10 1/8"
8' - 2 3/8"
/8
1' - 3 5/8"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E105
GUL105
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
3/4" = 1'-0"
RM E105
REFERENCE ROOM (2):
E105, E106
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
SPAN = 5' - 0''
E107
/8
/8
1' - 1 1/4"12' - 0"
/8
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E107
GUL106
KCA07/26/2022
PROJECT ID:103177
3/4" = 1'-0"
RM E107
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
E108
/8
9' - 11 1/2"
/4
1"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E108
GUL107
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
3/4" = 1'-0"
RM E108
REFERENCE ROOM (2):
E108, E113
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
E112
10 7/8" 10' - 1 3/4"
/2
10' - 8"10 7/8"
/8
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E112
GUL108
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Ceiling bracket, Standard
Hoist
Stabilizers
KEY
Hoist Transformer
Revision Schedule
Date Issued by Number
1/2" = 1'-0"
RM E112
Trolley Cut-Out
HOIST =1100 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
SPAN = 5' - 0''
B-RAIL SPAN LIMIT BETWEEN SUPPORTS IS 11' - 5" FOR 1100 LBS
E116
/8
8' - 2 3/8"
11' - 5"
3' - 9"
GUL104
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E116
GUL109
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
3/4" = 1'-0"
RM E116
Revision Schedule
Date Issued by Number
HOIST =1100 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
SPAN = 5' - 0''
B-RAIL SPAN LIMIT BETWEEN SUPPORTS IS 11' - 5" FOR 1100 LBS
E118
/8
9' - 10 1/8"
8' - 0"1' - 6 1/8"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E118
GUL110
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
3/4" = 1'-0"
RM E118
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
E119
/8
/8
9' - 10 1/8"
8' - 0"1' - 9 1/2"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E119
GUL111
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
3/4" = 1'-0"
RM E119
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
E121
1" 12' - 8 1/4"
/8
/8
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E121
GUL112
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
3/4" = 1'-0"
RM E121
REFERENCE ROOM (2):
E121 - E122
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
E123
12' - 7 7/8" 1"
/8
/4
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E123
GUL113
KCA07/26/2022
PROJECT ID:103177
Revision Schedule
Date Issued by Number
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
3/4" = 1'-0"
RM E123
REFERENCE ROOM (2):
E123 - E124
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 6''3.
ATTACHMENT TYPE = I-BEAM4.
E125 8
12' - 8 1/8" 1"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E125
GUL114
KCA07/26/2022
PROJECT ID:103177
3/4" = 1'-0"
RM E125
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 0''3.
ATTACHMENT TYPE = I-BEAM4.
SPAN = 5' - 0''
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
E151
12' - 11 5/8" 1"
/2
/8
/4
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
RM E151
GUL115
KCA07/26/2022
PROJECT ID:103177
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
1/2" = 1'-0"
RM E151
Revision Schedule
Date Issued by Number
HOIST =770 LBS1.
FLUSH RECESSED, TYPE G2.
CEILING HEIGHT = 9' - 6''3.
ATTACHMENT TYPE = I-BEAM4.
LMC-2
14'-6"
14'-6"
/8
16' - 7 1/4"
16' - 4 7/8"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
ACCURATE TO 4" BASED
ON PDF CONVERSION
Stratton ED
AMBULANCE CANOPY
GUL116
KCA07/26/2022
PROJECT ID:103177
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
C rail
HOIST = 1100 LBS1.
NON-RECESSED, TYPE C2.
CEILING HEIGHT = UNKNOWN3.
ATTACHMENT TYPE = I-BEAM4.
SPAN = 5' - 0''
Revision Schedule
Date Issued by Number
AFF TO DECK = UNKNOWN
1/4" = 1'-0"
AMBULANCE CANOPY
VERIFY SYSTEM SIZE AND LOCATION IN FIELD
VERIFY CEILING AND DECK HEIGHTS
| Sheets |
| GUL101 - FACILITY SIGNOFF |
| GUL102 - GEN. INFO |
| GUL103 - ATTACHMENT |
| GUL104 - PROJECT DETAILS |
| GUL105 - RM E105 |
| GUL106 - RM E107 |
| GUL107 - RM E108 |
| GUL108 - RM E112 |
| GUL109 - RM E116 |
| GUL110 - RM E118 |
| GUL111 - RM E119 |
| GUL112 - RM E121 |
| GUL113 - RM E123 |
| GUL114 - RM E125 |
| GUL115 - RM E151 |
| GUL116 - AMBULANCE CANOPY |
File details come from the government source that posted it. Updated .