This federal contract opportunity solicitation is for the installation of a 1000 KW diesel generator, fuel tank, and associated equipment at the Brooklyn VA Medical Center in New York. The scope of work includes installing a new generator on grade with a diesel sub-base fuel tank in an all-season housing and conduits to feeders. The fuel tank capacity will allow the generator to run for 96 hours at full load. An automatic transfer switch and output breakers will serve future loads. Remote monitoring panels will be installed to monitor the generator and fuel tank via the facility's building management system. The solicitation number is 36C24221B0061 and responses are due by August 27, 2021. The place of performance is the Brooklyn VA Medical Center and the contracting office is the VA Network Contracting Office.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S02 SPECS 5.pdf | ||
| S02 SPECS 1.pdf | ||
| S02 DRAWINGS 5.pdf | ||
| S02 DRAWINGS 4.pdf | ||
| S02 DRAWINGS 3.pdf | ||
| S02 SPECS 3.pdf | ||
| S02 SPECS 4.pdf | ||
| S02 SPECS 2.pdf | ||
| S02 ALL POSTERS.pdf | ||
| S02 ADDITIONAL INSERTS.pdf | ||
| S02 SPECS 6.pdf | ||
| S02 Participation Goals for Minorities and Females.pdf | ||
| S02 DRAWINGS 2.pdf | ||
| S02 DRAWINGS 1.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBJECT*
630A4-18-415 INSTALL GENERATOR FOR BUILDINGS 85 AND 86
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 11209 |
| SOLICITATION NUMBER* |
| 36C24221B0061 |
| RESPONSE DATE/TIME/ZONE |
| 08-27-2021 10:00 AM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 99 DAYS AFTER THE RESPONSE DATE |
CLASSIFICATION
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| Y1DA |
| NAICS CODE* |
| 238210 |
| PLACE OF PERFORMANCE |
| BROOKLYN VA MEDICAL CENTER |
800 POLY PLACE (138)
BUILDING #1, ROOM #6-228
BROOKLYN, NY 11209-0002
| POSTAL CODE |
| 11209 |
| COUNTRY |
| USA |
CONTACT INFORMATION
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 2
VLADIMIR STOYANOV (138)
800 POLY PLACE B: I R: 6-228
Bronx NY 10468-3904
POINT OF CONTACT*
VLADIMIR STOYANOV
CONTRACTING OFFICER
VLADIMIR.STOYANOV@VA.GOV
718- 836-6600 ext 8889
(ALL QUESTIONS MUST BE BY EMAIL ONLY)
ADDITIONAL INFORMATION
| AGENCY’S URL |
| http://www.va.gov |
| URL DESCRIPTION |
| WEBSITE |
| AGENCY CONTACT’S EMAIL ADDRESS |
| VLADIMIR.STOYANOV@VA.GOV |
| EMAIL DESCRIPTION |
| CONTRACTING OFFICER |
Presolicitation Notice Presolicitation Notice
DESCRIPTION
| *=Required Field |
| Presolicitation Notice |
Presolicitation Notice
STATEMENT OF WORK
630A4-18-415 INSTALL GENERATOR FOR BUILDINGS 85 AND 86
The scope of this project is a new 1000 KW diesel generator, Tier 4, 208Y/120V, which will be installed on grade, with a Diesel sub-base tank in an all-season housing/enclosure with conduits and feeders. The capacity of the fuel tank will allow the generator to run for 96 hours at a full load rating. In the weatherproof housing of the generator, an ATS will be located as well, with also the possibility of multiple output breakers to serve future loads from the generator. This ATS will back up the entire new 3000A switchgear to be located in the adjacent switchgear building. The generator will be provided with a remote generator and fuel tank monitoring/alarm panels. These panels will be located in the existing Vault 167. The panels will be wired to the facility BMS in the Engineering Service, Building 89. Via the facility BMS network, the generator and fuel tank can be viewed on the monitoring screen in Boiler Plant. Note that the design basis for the new generator uses an engine certified as US EPA Tier 4 due to the state and local environmental protection requirements. Engines certified as Tier 4 engines per 40 CFR 1039.101 are exempt from conducting the tests upon initial installation. The fuel tank monitoring system will conform with the latest EPA and NY Department of Environmental Protection requirements.
There will be improvements to the switchgear building to replace the roof and accommodate the routing of conduits from the generator. Some lead paint abatement will be required. Structure for Generator pad and Tier 4 exhaust, stairs, etc., will also be required. To facilitate this construction and switchover of the emergency power, temporary power from ConEd will be required and is detailed in the bid documents to be provided by this contract. Be aware the process with ConEd is already started and is approved for construction. Given the nature of the work and the desire to minimize downtime, the submittals and ordering of equipment will need.
All work described above is shown and described in the construction documents and specifications.
Training:
1. All contractor employees and subcontractor employees requiring access to VA information and VA information systems shall complete the following before being granted access to VA information and its systems:
1. Successfully complete VA Privacy Training for contractors who have no access to PHI or Access to TMS.
The contractor shall provide to the COR a copy of the training certificates and certification of signing the Contractor Rules of Behavior for each applicable employee within one week of the initiation of the contract and annually thereafter, as required.
Failure to complete the mandatory annual training and sign the Rules of Behavior annually, within the timeframe required, is grounds for suspension or termination of all physical or electronic access privileges and removal from work on the contract until such time as the training and documents are complete.
See attached document: S02 ADDITIONAL INSERTS.
See attached document: S02 Participation Goals for Minorities and Females.
See attached document: S02 ALL POSTERS.
See attached document: S02 DRAWINGS 1.
See attached document: S02 DRAWINGS 2.
See attached document: S02 DRAWINGS 3.
See attached document: S02 DRAWINGS 4.
See attached document: S02 DRAWINGS 5.
See attached document: S02 SPECS 1.
See attached document: S02 SPECS 2.
See attached document: S02 SPECS 3.
See attached document: S02 SPECS 4.
See attached document: S02 SPECS 5.
See attached document: S02 SPECS 6.
File details come from the government source that posted it. Updated .