HA102-Hazardous Materials Lead Paint Location Plan Ground Floor.pdf

PDF 631 KB Posted

Attached to
Y1DZ--620A4-14-118 Chiller Plant Upgrade
Solicitation number
36C24220B0045
Issued by

About this file

This document provides details for an upcoming federal contract opportunity to upgrade the chiller plant at the Hudson Valley Healthcare System Castle Point Campus in Castle Point, New York. The contractor shall provide all resources necessary to accomplish the upgrade, with a contract completion time of one thousand four hundred sixty calendar days after issuance of the Notice to Proceed. This procurement is a 100% set-aside for a Service-Disabled Veteran-Owned Small Business. Prospective contractors must be registered in the VetBiz and SAM databases. Bids will only be accepted from SDVOSBs determined to be responsible and responsive. The cost range is between $1,000,000 and $5,000,000, and bonds will be required. The solicitation is expected to be released on or around June 1, 2020. Questions must be received by May 31, 2020 and the bid submittal details will be in the solicitation.

View the file

Other files

File Type Posted
36C24220B0045_9.docx DOCX document
36C24220B0045_8.docx DOCX document
36C24220B0045_7.docx DOCX document
2020-07-16 Bidder Questions - MR Responses - 2.xlsx XLSX spreadsheet
36C24220B0045_6.docx DOCX document
Sign In.pdf PDF
36C24220B0045_5.docx DOCX document
36C24220B0045_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

E

F

G

2 3 4 5 6 7 8

(E) FD

(E) FD(E) FD

(E) FD

(E) FD

(E) FD

(E) FD

(E) FD

(E) FD

(E) FD

WORK AREA

WORK AREA

CHILLER ROOM

SWITCH GEAR ROOM

OFFICE

OFFICE

TOILET

NO. DESCRIPTION DATE

o n e e i g h t h i n c o e f o t

B

A

C

D

E

F t h r e e i n c h e s o t o n e a d a l f i n c h e s o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t 4 o n e q u a r t e r i n o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

PLAN

NORTH

ACTUAL

NORTH

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned

Small Business

SDVOSB

CVE

MR PROJECT NO: 0499-0110

B

A

C

D

E

F

KEYPLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseENGINEER OF RECORDCONSULTANT UPGRADE CHILLER PLANT

CASTLE POINT CAMPUS

WAPPINGERS FALLS, NY

620A4-14-118

Project Director

2020-03

HAZARDOUS MATERIALS

LEAD PAINT LOCATION PLAN

GROUND FLOOR

KS RG

TTI ENVIRONMENTAL, INC.

1253 North Church Street

Moorestown, NJ 08057

T 856.840.8800

F 856.840.8815

CONSULTING · CONTRACTING · ENGINEERING

HA102

BROWN

REAR DOOR

BROWN

STAIRS

ON CHILLER

GRAY PAINT

ON CHILLER

GREEN PAINT

ON PUMP

BLUE PAINT

RED PAINT ON I-BEAM

RED PAINT ON I-BEAM

GREEN PAINT ON CHILLER

BLUE PAINT ON PUMP

BROWN PAINT ON DOOR

BROWN PAINT STAIRS

GRAY PAINT ON CHILLER

L E G E N D

LEAD PAINT MATERIALS

BID DOCUMENTS

ON PUMP

BLUE PAINT

RED PAINT ON I-BEAMRED PAINT ON I-BEAM

R E

D

P

A I N

T

O

N

I B

E A

M

R E

D

P

A I N

T

O

N

I B

E A

M

R E

D

P

A I N

T

O

N

I B

E A

M

R E

D

P

A I N

T

O N

I B

E A

M

LEAD SAFE WORK PRACTICES:

1. Lead safe work practices shall follow the guidelines set forth by the

Occupational Safety and Health administration standard number 1926.62.

2. The contractor shall have an appropriate hand washing station at the job site.

3. All surfaces shall be maintained as free as practicable of accumulations of lead.

4. Clean-up of floors and other surfaces where lead accumulates shall wherever possible, be cleaned by vacuuming or other methods that minimize the likelihood of lead becoming airborne.

5. The employer shall provide clean change areas for employees whose airborne exposure to lead is above the PEL, and as interim protection for employees performing tasks, without regard to the use of respirators.

6. The employer shall provide shower facilities, where feasible, for use by employees whose airborne exposure to lead is above the PEL.

7. The employer shall post the following warning signs in each work area where an employee's exposure to lead is above the PEL.

DANGER

LEAD WORK AREA

MAY DAMAGE FERTILITY OR THE UNBORN CHILD

CAUSES DAMAGE TO THE CENTRAL NERVOUS SYSTEM

DO NOT EAT, DRINK OR SMOKE IN THIS AREA

8. Written plans for these compliance programs shall include at least the following:

A description of each activity in which lead is emitted; e.g. equipment used, material involved, controls in place, crew size, employee job responsibilities, operating procedures and maintenance practices; A description of the specific means that will be employed to achieve compliance and, where engineering controls are required engineering plans and studies used to determine methods selected for controlling exposure to lead; The compliance program shall provide for frequent and regular inspections of job sites, materials, and equipment to be made by a competent person.

GRAY PAINT ON FLOOR

Sheets and Views
Model

File details come from the government source that posted it. Updated .