About this file

36C24219B0039 H-101 ASBESTOS REMOVAL PLAN- Replace Roofs Buildings 65 85 86 87 and 88.pdf

View the file

Other files

File Type Posted
36C24219B0039-0002002.pdf PDF
36C24219B0039-0002001.pdf PDF
36C24219B0039-0002000.docx DOCX document
36C24219B0039-0001000.docx DOCX document
36C24219B0039-007.pdf PDF
36C24219B0039-003.pdf PDF
36C24219B0039-004.pdf PDF
36C24219B0039-006.pdf PDF
36C24219B0039-011.pdf PDF
36C24219B0039-002.pdf PDF
36C24219B0039-009.pdf PDF
36C24219B0039-005.pdf PDF
36C24219B0039-010.pdf PDF
36C24219B0039-008.pdf PDF
36C24219B0039-001.docx DOCX document
36C24219B0039-000.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

ASBESTOS REMOVAL PLAN:

AutoCAD SHX Text

ASBESTOS ABATEMENT SHALL BE PERFORMED IN ACCORDANCE WITH SPECIFICATION

AutoCAD SHX Text AND APPLICABLE REGULATIONS. PERSONNEL HOLDING CURRENT NYS DEPARTMENT OF LABOR (NYSDOL) ASBESTOS

AutoCAD SHX Text HANDLER'S CERTIFICATES SHALL PERFORM THE WORK. ADDITIONALLY, THE CONTRACTOR MUST EMPLOY

AutoCAD SHX Text NYCDEP AND NYSDOL CERTIFIED SUPERVISORS TO BE ON THE WORK SITE FOR ALL ABATEMENT ACTIVITIES.

AutoCAD SHX Text ALL CERTIFICATIONS AND LICENSES ARE TO BE READILY AVAILABLE FOR VERIFICATION BY STAFF.

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL ASBESTOS-CONTAINING MATERIALS

AutoCAD SHX Text

AND ASBESTOS-CONTAMINATED MATERIALS ON SITE.

AutoCAD SHX Text 1)

AutoCAD SHX Text 2)

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR HIRING AIR MONITORING COMPANY TO PERFORM REQUIRED BACKGROUND AIR MONITORING

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE INTEGRITY OF THE FINISHES. THE CONTRACTOR SHALL REPAIR

AutoCAD SHX Text

ANY AND ALL DAMAGES CAUSED BY ABATEMENT ACTIVITIES AND/OR THEIR PERSONNEL.

AutoCAD SHX Text CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES AND FOR

AutoCAD SHX Text 3)

AutoCAD SHX Text

COORDINATING ALL PORTIONS OF THE SCOPE OF WORK UNDER THIS CONTRACT.

AutoCAD SHX Text WORK MAY HAVE TO BE PERFORMED OFF-HOURS AND/OR WEEKENDS AT NO ADDITIONAL COST TO THE VAMC.

AutoCAD SHX Text 4)

AutoCAD SHX Text

GENERAL NOTES:

AutoCAD SHX Text THROUGHOUT ALL SUBJECT ROOFS WITHIN THIS PROJECT, AS WELL AS GENERATION OF ASBESTOS REPORTS FOR COR.

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL QUANTITIES OF ACM, AS WELL AS FOR PRE-CLEANING ANY

AutoCAD SHX Text

EXISTING ASBESTOS CONTAMINATION, DUST, AND DEBRIS WITHIN THE REMOVAL AREAS.

AutoCAD SHX Text 5)

AutoCAD SHX Text 6)

AutoCAD SHX Text THE ENTIRE ROOF (TYP) SHALL BE CONSIDERED THE ASBESTOS ABATEMENT WORK AREA. ONLY NYSDOL

AutoCAD SHX Text CERTIFIED ASBESTOS WORKERS AND AUTHORIZED VISITORS SHALL BE PERMITTED IN THE ROOF WORK AREA DURING ABATEMENT.

AutoCAD SHX Text 7)

AutoCAD SHX Text ROOF WORK AREAS SHALL NOT REQUIRE AIR CLEARANCE SAMPLES. THE ROOF WILL BE CONSIDERED ABATED WHEN THERE

AutoCAD SHX Text IS NO VISIBLE DEBRIS OR DUST REMAINING AND THE NEW YORK STATE LICENSED PROJECT MONITOR

AutoCAD SHX Text 8)

AutoCAD SHX Text THE LOCATION OF THE REMOTE DECONTAMINATION UNITS AND WASTE DUMPSTER SHALL BE MUTUALLY AGREED UPON DURING

AutoCAD SHX Text

THE PRECONSTRUCTION MEETING BY THE VAMC AND ASBESTOS ABATEMENT CONTRACTOR.

AutoCAD SHX Text 9)

AutoCAD SHX Text THE ASBESTOS ABATEMENT SHALL BE COORDINATED TO AVOID INTERRUPTIONS TO THE NORMAL ACTIVITIES OF THE VAMC.

AutoCAD SHX Text 10)

AutoCAD SHX Text THE ASBESTOS ABATEMENT CONTRACTOR SHALL COORDINATE WORK WITH THE ROOFING CONTRACTOR SO THAT THE BUILDING IS NOT LEFT

AutoCAD SHX Text

COMPROMISED AND EXPOSED TO THE NATURAL ELEMENTS, SUCH AS WATER/WEATHER DAMAGE.

AutoCAD SHX Text 11)

AutoCAD SHX Text A MINIMUM DISTANCE OF 25FT SHALL BE MAINTAINED BETWEEN THE ASBESTOS WORK AREA AND ADJACENT NON-ASBESTOS AREAS.

AutoCAD SHX Text

HAS PERFORMED A SUCCESSFUL VISUAL INSPECTION.

AutoCAD SHX Text THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL DAMAGE RESULTING FROM ASBESTOS ABATEMENT ACTIVITIES.

AutoCAD SHX Text 12)

AutoCAD SHX Text THE CONTRACTOR SHALL COMPLY WITH ALL REGULATIONS CONCERNING OSHA FALL PROTECTION.

AutoCAD SHX Text 13)

AutoCAD SHX Text HVAC INTAKES AND EXHAUST, LABORATORY EXHAUSTS, VENTS, AND DRAINS THAT CAN NOT BE SHUT OFF OR SEALED WITH TWO LAYERS

AutoCAD SHX Text 14)

AutoCAD SHX Text OF 6MIL PLASTIC SHEETING MUST BE EXTENDED USING AN AIRTIGHT RIGID SHEATHING, TO A MINIMUM OF 10FT ABOVE THE WORK AREA, DURING ABATEMENT.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text

BUILDING NO. 85

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text

BUILDING NO. 65

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text

BUILDING NO. 87

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text

BUILDING NO. 86

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text

BUILDING NO. 88

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text R.D.

AutoCAD SHX Text

APPROVED: SERVICE DIRECTOR

AutoCAD SHX Text

APPROVED: DIVISION CHIEF

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

V.A. EXTENDED CARE CENTER

AutoCAD SHX Text

65,85,86,87 AND 88

AutoCAD SHX Text

ST.ALBANS,NY.

AutoCAD SHX Text

LOCATION

AutoCAD SHX Text

BUILDING NUMBER

AutoCAD SHX Text

ALL

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

REPLACE ROOFS BUILDINGS

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text H-101

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

KV

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

19-01-SA

AutoCAD SHX Text 5-1-2019

AutoCAD SHX Text 630A4-17-434

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

VETERAN'S AFFAIRS

AutoCAD SHX Text

DEPARTMENT OF

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text N/A

AutoCAD SHX Text

SHT. 9 OF 9

AutoCAD SHX Text

ASBESTOS REMOVAL PLAN

AutoCAD SHX Text

ISSUE FOR BID

AutoCAD SHX Text 5/1/19

AutoCAD SHX Text

PC, JM

Sheets and Views
Replace Roofs Buildings 65 85 86 87 and 88- H-101 ASBESTOS REMOVAL PLAN-Layout1