36C24219B0039-011.pdf
PDF 242 KB Posted
- Solicitation number
- 36C24219B0039
About this file
36C24219B0039 A-501 ROOF DETAILS- Replace Roofs Buildings 65 85 86 87 and 88.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24219B0039-0002002.pdf | ||
| 36C24219B0039-0002001.pdf | ||
| 36C24219B0039-0002000.docx | DOCX document | |
| 36C24219B0039-0001000.docx | DOCX document | |
| 36C24219B0039-007.pdf | ||
| 36C24219B0039-003.pdf | ||
| 36C24219B0039-004.pdf | ||
| 36C24219B0039-012.pdf | ||
| 36C24219B0039-006.pdf | ||
| 36C24219B0039-002.pdf | ||
| 36C24219B0039-009.pdf | ||
| 36C24219B0039-005.pdf | ||
| 36C24219B0039-010.pdf | ||
| 36C24219B0039-008.pdf | ||
| 36C24219B0039-001.docx | DOCX document | |
| 36C24219B0039-000.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
OR APPROVED EQUAL
AutoCAD SHX Text
ACCEPTABLE COVERBOARD
AutoCAD SHX Text
ADHERED TO INSULATION
AutoCAD SHX Text
ACCEPTABLE URETHANE
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
AGGREGATE BONDING RESIN. (NOT REQUIRED)
AutoCAD SHX Text
APPROVED SUBSTRATE PREPARED PER MANUFACTURER REQUIREMENTS
AutoCAD SHX Text
KEMPERTEC PRIMER (O.A.E.) APPLIED TO COVERBOARD
AutoCAD SHX Text
OR APPROVED EQUAL
AutoCAD SHX Text
SURFACING OR COATING
AutoCAD SHX Text
(IF REQUIRED)
AutoCAD SHX Text
KEMPEROL MEMBRANE
AutoCAD SHX Text
ACCEPTABLE KEMPERDUR AGGREGATE
AutoCAD SHX Text
(NOT REQUIRED)
AutoCAD SHX Text
AGGREGATE SEALING RESIN
AutoCAD SHX Text
ACCEPTABLE RIGID INSULATION SECURED/ADHERED TO SUBSTRATE
AutoCAD SHX Text
%%UINSULATED WATERPROOFING ASSEMBLY W/ FOAM
AutoCAD SHX Text
%%UINSULATION & COVERBOARD
AutoCAD SHX Text
MEMBRANE (O.A.E.) @ WALL TO DECK TRANSITION
AutoCAD SHX Text
EXTEND 4" MIN. HORIZONTALLY ONTO
AutoCAD SHX Text
CONTINUOUS 4" WIDE STRIP OF KEMPEROL
AutoCAD SHX Text
(1) PLY KEMPEROL (O.A.E.) MEMBRANE FLASHING
AutoCAD SHX Text
FIELD SUBSTRATE.
AutoCAD SHX Text
COMPOUND PRIOR TO APPLICATION OF
AutoCAD SHX Text
KEMPERTEC (O.A.E.) PRIMER & KEMPEROL MEMBRANE
AutoCAD SHX Text
PREPARE, LEVEL & PATCH SUBSTRATE
AutoCAD SHX Text
AS REQUIRED W/APPROVED LEVELING
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
KEMPEROL (O.A.E.) FIELD MEMBRANE
AutoCAD SHX Text
COUNTERFLASHING AS REQUIRED
AutoCAD SHX Text
POLYURETHANE CAULKING
AutoCAD SHX Text
8" MINIMUM
AutoCAD SHX Text
OR APPROVED EQUAL (O.A.E.) (TYP.)
AutoCAD SHX Text
%%UDRAIN FLASHING
AutoCAD SHX Text
KEMPEROL (O.A.E.) FIELD MEMBRANE
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
CONTINUOUS BOTTOM PLY OF KEMPEROL (O.A.E.)
AutoCAD SHX Text
MEMBRANE @ WALL TO DECK TRANSITION
AutoCAD SHX Text
EXTEND THRU TO INSIDE OF OPENING
AutoCAD SHX Text
(1) PLY KEMPEROL (O.A.E.) MEMBRANE FLASHING
AutoCAD SHX Text
POLYURETHANE CAULKING
AutoCAD SHX Text
COUNTERFLASHING AS REQUIRED
AutoCAD SHX Text
ONTO FIELD SUBSTRATE.
AutoCAD SHX Text
(1) PLY KEMPEROL (O.A.E.) MEMBRANE FLASHING
AutoCAD SHX Text
EXTEND 4" MIN. HORIZONTALLY
AutoCAD SHX Text
KEMPEROL (O.A.E.) FIELD
AutoCAD SHX Text 2"
AutoCAD SHX Text
MEMBRANE FLASHING. EXTEND
AutoCAD SHX Text
(1) PLY KEMPEROL (O.A.E.)
AutoCAD SHX Text
POLYURETHANE CAULKING
AutoCAD SHX Text
COUNTERFLASHING AS REQUIRED
AutoCAD SHX Text
KEMPEROL (O.A.E.) FIELD MEMBRANE EXTENDED
AutoCAD SHX Text
(1) PLY KEMPEROL (O.A.E.) MEMBRANE FLASHING-EXTEND
AutoCAD SHX Text
6" MIN. OVER KEMPEROL (O.A.E.) DRAIN FLASHING.
AutoCAD SHX Text
MINIMUM OF 3" INTO PREPARED AND PRIMED
AutoCAD SHX Text
DRAIN BOWL.
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
PREPARE, LEVEL & PATCH SUBSTRATE
AutoCAD SHX Text
CLAMP RING
AutoCAD SHX Text
KEMPEROL (O.A.E.) RESIN/SAND FILL
AutoCAD SHX Text
AS REQUIRED TO DEVELOP
AutoCAD SHX Text
SMOOTH TRANSITION
AutoCAD SHX Text
ACCEPTABLE ROOF DRAIN ASSEMBLY
AutoCAD SHX Text
(OPTIONAL)
AutoCAD SHX Text
OVERLAP
AutoCAD SHX Text
AS REQUIRED W/APPROVED LEVELING
AutoCAD SHX Text
COMPOUND PRIOR TO APPLICATION OF
AutoCAD SHX Text
KEMPERTEC (O.A.E.) PRIMER & KEMPEROL (O.A.E.) MEMBRANE
AutoCAD SHX Text
PREPARE & PRIME DRAIN BOWL AS REQ'D.
AutoCAD SHX Text
FOR KEMPEROL (O.A.E.) MEMBRANE APPLICATION
AutoCAD SHX Text
MEMBR. & WALL GREATER THAN 1/16" (TYP.)
AutoCAD SHX Text
CONT. BEAD OF POLYURETHANE CAULKING
AutoCAD SHX Text
REQ.'D IF GAP BETWEEN EDGE OF MODIFIED
AutoCAD SHX Text
ASSURE FULL CONTACT OF COMPOSITE W/
AutoCAD SHX Text
SUBSTRATE & RESIN SATURATION OF FLEECE.
AutoCAD SHX Text
CONTINUOUS 4" WIDE STRIP OF KEMPEROL
AutoCAD SHX Text
MEMBRANE @ WALL TO DECK TRANSITION
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
AS REQUIRED W/APPROVED LEVELING
AutoCAD SHX Text
PREPARE, LEVEL & PATCH SUBSTRATE
AutoCAD SHX Text
KEMPEROL PRIMER & MEMBRANE.
AutoCAD SHX Text
COMPOUND PRIOR TO APPLICATION OF
AutoCAD SHX Text
MODIFIED BITUMEN ROOF MEMBRANE.
AutoCAD SHX Text
(1) PLY KEMPEROL MEMBRANE FLASHING
AutoCAD SHX Text
EXTEND 12" MIN. HORIZONTALLY ONTO
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
OUTSIDE EDGE OF WALL.
AutoCAD SHX Text
TERMINATE KEMPEROL MEMBRANE @
AutoCAD SHX Text
MASONRY COPING STONE SET IN
AutoCAD SHX Text
MORTAR BED AS REQUIRED.
AutoCAD SHX Text
TO BE ENCAPSULATED W/KEMPEROL
AutoCAD SHX Text
ACCEPTABLE ALKALINITY PROTECTION
AutoCAD SHX Text
ALL DOWELS & PENETRATING FASTENERS
AutoCAD SHX Text
MEMBRANE TERMINATION POINTS.
AutoCAD SHX Text
ANGLED RESIN FILL TYPICAL @ ALL
AutoCAD SHX Text
(OPTIONAL)
AutoCAD SHX Text
CAP SHEET SET IN ADHESIVE OR HEAT WELDED
AutoCAD SHX Text
BASE SHEET SET IN ADHESIVE OR HEAT WELDED
AutoCAD SHX Text
APPROVED SUBSTRATE
AutoCAD SHX Text
METAL SILL FLASHING SET IN
AutoCAD SHX Text
BED OF SEALANT (BY OTHERS)
AutoCAD SHX Text
ASSURE FULL CONTACT OF COMPOSITE W/
AutoCAD SHX Text
MEMBRANE @ WALL TO DECK TRANSITION.
AutoCAD SHX Text
EXTEND 4" MIN. HORIZONTALLY
AutoCAD SHX Text
SUBSTRATE & RESIN SATURATION OF FLEECE
AutoCAD SHX Text
CONTINUOUS 4" WIDE STRIP OF KEMPEROL (O.A.E.)
AutoCAD SHX Text
KEMPEROL (O.A.E.) MEMBRANE FLASHING
AutoCAD SHX Text
ONTO FIELD SUBSTRATE.
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
KEMPEROL (O.A.E.) FIELD MEMBRANE
AutoCAD SHX Text
MEMBRANE FLASHING UNDER METAL SILL
AutoCAD SHX Text
PLATE & REINSTALL SET SILL PLATE IN BED
AutoCAD SHX Text
IF VERTICAL HEIGHT OF FLASHING IS LESS
AutoCAD SHX Text
THAN 6" MINIMUM, EXTEND KEMPEROL (O.A.E.)
AutoCAD SHX Text
OF POLYURETHANE SEALANT. (RECOMMENDED
AutoCAD SHX Text
6" MINIMUM
AutoCAD SHX Text 2"
AutoCAD SHX Text
IN CORNER AREA.
AutoCAD SHX Text
SIDES OF DOOR OPENING
AutoCAD SHX Text
EXTEND FLASHING 2" UP
AutoCAD SHX Text
FOR ALL CONDITIONS)
AutoCAD SHX Text
%%UPARAPET WALL FLASHING
AutoCAD SHX Text
POWER TOOL CLEAN TUBE
AutoCAD SHX Text
STEEL PER SSPC-SP3.
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
WRAPPED AROUND PIPE W/
AutoCAD SHX Text
KEMPEROL (O.A.E.) MEMBRANE SKIRT
AutoCAD SHX Text
2" MIN. OVERLAP
AutoCAD SHX Text
CUT INSIDE DIA. 1/2" SMALLER
AutoCAD SHX Text
KEMPEROL (O.A.E.) MEMBRANE COLLAR
AutoCAD SHX Text
THAN PIPE DIAMETER
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
CUT TIGHT TO PENETRATION
AutoCAD SHX Text
KEMPEROL (O.A.E.) FIELD MEMBRANE
AutoCAD SHX Text
1" (TYP)
AutoCAD SHX Text
RADIAL CUTS TO SKIRT
AutoCAD SHX Text 3"
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
AS REQUIRED
AutoCAD SHX Text
%%UDOOR SILL FLASHING
AutoCAD SHX Text
%%UPIPE PENETRATION FLASHING
AutoCAD SHX Text
THRU TO INSIDE OF OPENING
AutoCAD SHX Text
MEMBRANE
AutoCAD SHX Text
%%U1 PLY BASE FLASHING WITH COUNTERFLASHING
AutoCAD SHX Text
%%UTHRU-WALL SCUPPER FLASHING
AutoCAD SHX Text
%%UTHRU-WALL FLUSH SCUPPER FLASHING
AutoCAD SHX Text
%%UDETAIL B
AutoCAD SHX Text
%%UDETAIL A
AutoCAD SHX Text
%%UDETAIL C
AutoCAD SHX Text
%%UDETAIL D
AutoCAD SHX Text
%%UDETAIL E
AutoCAD SHX Text
%%UDETAIL F
AutoCAD SHX Text
%%UDETAIL G
AutoCAD SHX Text
%%UDETAIL H
AutoCAD SHX Text
APPROVED: SERVICE DIRECTOR
AutoCAD SHX Text
APPROVED: DIVISION CHIEF
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
V.A. EXTENDED CARE CENTER
AutoCAD SHX Text 65,85,86,87 and 88
AutoCAD SHX Text
ST.ALBANS,NY.
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text 65,85,86,87,88
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
REPLACE ROOFS BUILDINGS
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text A-501
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
KV
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
19-01-SA
AutoCAD SHX Text 5-1-2019
AutoCAD SHX Text 630A4-17-434
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
VETERAN'S AFFAIRS
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text N/A
AutoCAD SHX Text
SHT. 8 OF 9
AutoCAD SHX Text
ROOF DETAILS
AutoCAD SHX Text
ISSUE FOR BID
AutoCAD SHX Text 5/1/19
AutoCAD SHX Text
PC
| Sheets and Views |
| Replace Roofs Buildings 65 85 86 87 and 88- A-501 ROOF DETAILS-Layout1 |
File details come from the government source that posted it.