36C24119R0074 S02 Drawings In-Patient Pharmacy IV 1 OF 3.pdf

View the file

Other files

File Type Posted
36C24119C0093-000.docx DOCX document
36C24119R0074-0007001.pdf PDF
36C24119R0074-0007000.docx DOCX document
36C24119R0074-0007001.pdf PDF
36C24119R0074-0007000.docx DOCX document
36C24119R0074-0006001.pdf PDF
36C24119R0074-0006000.docx DOCX document
36C24119R0074-0006002.pdf PDF
36C24119R0074-0006000.docx DOCX document
36C24119R0074-0006001.pdf PDF
36C24119R0074-0006002.pdf PDF
36C24119R0074-0005000.docx DOCX document
36C24119R0074-0005000.docx DOCX document
36C24119R0074-0004001.pdf PDF
36C24119R0074-0004000.docx DOCX document
36C24119R0074-0004001.pdf PDF
36C24119R0074-0004000.docx DOCX document
36C24119R0074-0003001.pdf PDF
36C24119R0074-0003003.pdf PDF
36C24119R0074-0003002.pdf PDF
36C24119R0074-0003000.docx DOCX document
36C24119R0074-0003001.pdf PDF
36C24119R0074-0003003.pdf PDF
36C24119R0074-0003000.docx DOCX document
36C24119R0074-0003002.pdf PDF
36C24119R0074-0002000.docx DOCX document
36C24119R0074-0002000.docx DOCX document
36C24119R0074-0001000.docx DOCX document
36C24119R0074-0001000.docx DOCX document
36C24119R0074-003.pdf PDF
36C24119R0074-007.pdf PDF
36C24119R0074-004.pdf PDF
36C24119R0074-006.pdf PDF
36C24119R0074-002.docx DOCX document
36C24119R0074-003.pdf PDF
36C24119R0074-006.pdf PDF
36C24119R0074-004.pdf PDF
36C24119R0074-005.pdf PDF
36C24119R0074-002.docx DOCX document
36C24119R0074-007.pdf PDF
36C24119R0074-001.docx DOCX document
36C24119R0074-001.docx DOCX document
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8.5

16A

35A

WEST SPRING STREET

36A

SHELTER

15A

SERVICE ROAD

SERVICE ROAD

2A

PET

LC1A

8.5

16A

35A

36A

15A

6A

2A

TITLE SHEET WITH

INDEX TO DRAWINGS

SITE MAP

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% FOR BID

TUBE SYSTEMCO

UN

TE

R

EXAM

G206

EXAM

G205

VESTIBUL

G204

HIGH RISK

PHASE I

CONSTRUCTION

PHASE II

CONSTRUCTION

ICRA PLAN & NOTES

NOTES:

PATIENT RISK GROUP FOR "TYPE D" CONSTRUCTION

LOW RISK GROUP

MEDIUM RISK GROUP

HIGH RISK GROUP

HIGHEST RISK GROUP Class IV

Class III / IV

Class IV Class IV

UL U465 (1 HOUR RATED)

FIRECODE 'X' GYPSUM BD PANELS

APPLIED VERTICALLY OR

HORIZONTALLY. HORIZONTAL JOINTS

NEED NOT BE STAGGERED. FACE

LAYER JOINTS TO BE FINISHED. FIRE

CAULK ALL PENETRATIONS.

CONSTRUCTION PARTITION WALL DETAIL

N.T.S.2

GROUND ICRA FLOOR PLAN1

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% FOR BID

PHASING NOTES:

PARTIAL MECHANICAL

SITE PLAN

PARTIAL MECHANICAL SITE PLAN1

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% FOR BID

TYPICAL CHAIN LINK FENCE AND GATE2

KEYED NOTES:

SECTION VIEW

FIRE/SMOKE RATING (SEE

3-AS-500 FOR PARTITION

LEGEND)

NOMINAL SIZE

SPECIFICATION CATEGORY

SEQUENCE NUMBER

DOOR NUMBER

DOOR SIZE (SEE 3-AS-600

FOR DOOR SIZE LEGEND)

VIEW NUMBER

SHEET NUMBER

VIEW NUMBER

SHEET NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW NUMBER

SHEET NUMBER

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

ARCHITECTURAL: SYMBOLS,

ABBREVIATIONS AND NOTES

20" HIGH CRAWL SPACE AREA, V.I.F.

FIRE/SMOKE RATING

(SEE 3-AS-500 FOR

PARTITION LEGEND)

NOMINAL SIZE

SPECIFICATION

CATEGORY

SEQUENCE NUMBER

DOOR NUMBER

DOOR SIZE (SEE

3-AS-600 FOR DOOR

SIZE LEGEND)

VIEW NUMBER

SHEET NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW

NUMBER

SHEET

NUMBER

3-AS-000

# 3-AS-00

NEW WALL AND DOOR

EXISTING WALL AND

DOOR TO REMAIN

NEW DOOR TAG

NEW PARTITION TAG

NEW WALL

SECTION TAG

NEW DETAIL

CALLOUT TAG

NEW INTERIOR

ELEVATION TAG

3-AS-000

000 EQUIPMENT TAG

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

EXISTING FLOOR PLAN

EXISTING CRAWL SPACE

AND ROOF PLAN

2 22

PHASE I

PARTITION TO

REMAIN DURING

PHASE II. PHASE II ENTRY.

PHASE I ENTRYREMOVE WINDOW, CUT & PATCH WALL FOR TEMPORARY

PHASE I ENTRY. WINDOW TO BE REINSTALLED AND WALL TO

BE RECONSTRUCTED AT END OF PHASE I. (SEE NOTE #16)

PHASE II

PARTITION

PHASE I

PARTITION

PHASE I

PARTITION

PHASE II

INTERIOR

WORK AREA

PHASE I

INTERIOR

WORK AREA19

PHASE II ENTRY.

PHASE II ENTRY: CUT &

PATCH EXTERIOR WALL

FOR TEMPORARY PHASE II

ENTRY (SIMILAR TO NOTE

#16, EXCEPT - SINGLE

3'-0"x 6'-8" HOLLOW METAL

DOOR & FRAME)

PHASE I

PARTITION TO

REMAIN DURING

PHASE II. PHASE II ENTRY.

PHASE I ENTRY

PHASE II

PARTITION

PHASE I

PARTITION

PHASE I

PARTITION

PHASE II

INTERIOR

WORK AREA

PHASE I

INTERIOR

WORK AREA

PHASE II ENTRY.

1. DRAWING SHOWS GENERAL EXTENT OF DEMOLITION AND

REMOVALS. THE CONTRACTOR SHALL MAKE ALL REMOVAL

AS REQUIRED TO PROPERLY INSTALL ALL NEW WORK. SEE

PHASING/ICRA.

2.DEMOLITION AND REMOVALS SHALL BE PERFORMED SO

THAT EXISTING FINISHES, EQUIPMENT, AND SYSTEMS THAT

ARE TO REMAIN ARE NOT DAMAGED. PROVIDE PROTECTION

AS NEEDED TO ENSURE THAT THESE ITEMS ARE NOT

DAMAGED.

3.SEE MEP DRAWINGS FOR THOSE REMOVALS. ALL

ABANDONED WIRING, PIPING AND EQUIPMENT SHALL BE

REMOVED EXCEPT THOSE IN EXISTING WALL AND SLABS

THAT ARE TO REMAIN. PROPERLY CAP AND/OR TERMINATE

ABANDONED PIPING AND WIRING THAT REMAINS.

4.ERECT NEW TEMPORARY PARTITIONS UP TO DECK ABOVE AS

REQUIRED BY NFPA 241, SECTION 8.6.2.1 WITH A MINIMUM OF

1-HOUR RATING AND SMOKE TIGHT. COMPLY WITH THE JOINT

COMMISSIONS STANDARDS AND AS REQUIRED TO PROTECT

ADJACENT SPACES FROM DUST MIGRATION. PROVIDE AND

INSTALL RATED (45MIN) AND SEALED ACCESS DOORS AS

REQUIRED FOR STAGING AND PHASING, COMPLETE WITH ALL

REQUIRED HARDWARE AND CLOSURES. ALL EXISTING

PENETRATIONS TO BE SEALED AND TEMPORARY FIRE/SMOKE

DAMPERS INSTALLED AT ALL DUCT PENETRATIONS AT LINE

OF NEW TEMPORARY WALL. CUT AND PATCH AS REQUIRED

ALL EXISTING FINISHES TO INSTALL NEW TEMPORARY

CONSTRUCTION SEPARATION WALLS. CONTRACTOR TO

PATCH AND REPAIR ALL EXISTING

SURFACES/FINISHES/CONSTRUCTION AS REQUIRED WHEN

TEMPORARY WALLS ARE REMOVED AT COMPLETION OF

PROJECT. COORDINATE WITH PHASING/ICRA DRAWINGS TO BE

MINIMUM OF STC 50 RATING.

5.GENERAL CONTRACTOR IS TO NOTIFY THE ARCHITECT/VA

IMMEDIATELY FOLLOWING FINDING PIPING, CHASES,

DUCTWORK, ETC. WITHIN THE WALLS TO BE DEMOLISHED

THAT WILL CAUSE CHANGE IN DESIGN.

6. ALL CONSTRUCTION DEBRIS TO BE REMOVED AFTER 5PM IF

USING ELEVATOR. ALL DEBRIS SHALL BE REMOVED IN A

COVERED BUGGY. COORDINATE WITH C.O.R. AND REFER TO

PHASING/ICRA DRAWING FOR ADDITIONAL INFORMATION.

7.USE OF A JACK HAMMER IS NOT PERMITTED.

8.COORDINATE WITH VA C.O.R. FOR AFTER HOURS WORK FOR

ALL NOISY (HIGH DECIBEL) WORK.

9.COORDINATE WITH VA C.O.R. FOR AFTER HOURS WORK TO

REMOVE EXISTING MATERIALS; USE OF A JACK HAMMER IS

NOT PERMITTED.

10. COORDINATE ALL DEMOLITION WORK WITH ASBESTOS

ABATEMENT WORK.

11. ALL WALL MOUNTED POSTERS, POSTER BOARDS,

ARTWORK, PHOTOGRAPHS AND SIGNAGE TO BE CAREFULLY

REMOVED AND RETURNED TO THE VA C.O.R. FOR RE-USE.

DEMOLITION NOTES

DEMOLITION PLAN LEGEND

EXISTING PARTITION

TO BE DEMOLISHED

EXISTING DOOR TO

BE DEMOLISHED

EXISTING PARTITION

TO REMAIN

EXISTING DOOR

TO REMAIN

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

DEMOLITION PLAN

DEMOLITION CEILING PLAN

DEMOLITION KEYNOTES

Number Note

1 TEMPORARY PARTITIONS, SEE GENERAL DEMOLITION NOTE #4.

REMOVE EXISTING INTERIOR PARTITION COMPLETE. CUT, PATCH

AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED FOR

SURFACES TO BE FLUSH & MATCH EXISTING.

CONTRACTOR TO REMOVE EXISTING EQUIPMENT. BSC

CABINETS, LAMINAR FLOW HOODS TO BE REUSED IN THE NEW

FLOOR PLAN, COORDINATE AS REQUIRED.

REMOVE EXISTING FLOORING AND CLEAN AND PREP FOR NEW

FLOORING. CUT, PATCH AND REPAIR ADJACENT FINISHES TO

REMAIN AS REQUIRED.

5 REMOVE EXISTING CEILING SYSTEM COMPLETELY. CUT, PATCH

AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED.

6 REMOVE EXISTING DOOR AND FRAME COMPLETE. CUT, PATCH

AND REPAIR ADJACENT FINISHES AS REQUIRED.

7 CONTRACTOR TO REMOVE EXISTING EQUIPMENT AND PROVIDE

TO VA.

REMOVE EXISTING WINDOW AND FRAME COMPLETE. CUT, PATCH

AND REPAIR ADJACENT FINISHES AS REQUIRED. SEE FLOOR PLAN

FOR AREAS TO RECEIVE NEW INFILL FRAMING AND PREPARE

OPENING TO RECEIVE NEW INFILL. INFILL TO BE FLUSH WITH

EXISTING WALL.

REMOVE EXISTING PLUMBING FIXTURES COMPLETE AND CAP OFF

ALL LINES. CUT, PATCH AND REPAIR ADJACENT FINISHES TO

REMAIN AS REQUIRED.

11 REMOVE EXISTING COUNTER/WALL CASEWORK AND LOCKERS

COMPLETE. PATCH AND REPAIR ADJACENT FINISHES AS REQUIRED.

REMOVE EXISTING CEILING SYSTEM AND INSTALL NEW CEILING

SYSTEM AS REQUIRED TO INSTALL NEW MEP WORK. CUT, PATCH

AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED.

15 REMOVE EXISTING FRAMED WALL AND GYPSUM BOARD FINISH.

17 EXISTING MECHANICAL UNITS TO BE REMOVED. SEE MEP

DRAWINGS. TYPICAL.

18 REMOVE EXISTING WINDOW COMPLETE. PREPARE SURFACE TO

RECEIVE NEW WINDOW.

SYMBOL

"CONTRACTOR TO INSTALL NEW TEMPORARY PAINTED HOLLOW

MTL FRAME AND DOOR PAIR (CLEAR OPENING OF AT LEAST 6'x

HEIGHT OF EXIST WINDOW FRAME, V.I.F) FOR PHASE I ENTRY

FROM THE EXTERIOR AS LOCATED ON DRAWING 1-AS-D100. THIS

PAIR OF DOORS PROVIDED BY THE CONTRACTOR W/ ALL REQ'D

HARDWARE & LOCKING DEVICES TO SECURE THE BUILDING

ENVELOPE FOR WEATHER TIGHTNESS AND SECURITY PURPOSES

AND PROVIDE PROPER ACCESS FOR THE CONTRACTOR TO THE

PROJECT AREA (MORTISE STOREROOM LOCKSET AND CLOSER,

ETC...). CONTRACTOR TO PROVIDE TEMPORARY ACCESS STAIRS

AS REQ'D TO PROPERLY ACCESS THE TEMPORARY DOORS AND

MEET ALL OF THE CODE REQUIREMENTS."

19 CONTRACTOR TO INSTALL NEW (1HR) RATED SHAFTWALL UP TO

DECK ABOVE ON EXISTING PARTITION FOR CONST. SEPARATION

PRIOR TO OTHER CONSTRUCTION.

EXIST ELECTRICAL PANELS

4'-0"

CLEAR

3'- 9"

'-3

LAMINAR

FLOW HOOD

LAMINAR

FLOW HOOD

SHELVING

HW SINK

STERILE SIDE

DE

MA

RC

AT

IO

N

LIN

E

'-6

18'-11 1/2"

33'-7" 20'-2"

'-3

4'-

2 1 /2"

'-2

1/ 2"

ENTRY

6'-6"

EXISTING ENTRY

TO PHARMACY

PR

IN

TE

R

REF

MOBILE

CART

EW

BSC

3'- 6"

MI

N

MOBILE

CART

6' SHELVING

WORK STATION

8'-0"

REF

REFBSC

MOBILE

CART

MOBILE

CART

MOBILE

CART

DOFFING ZONE

FREEZER

BELOW

MOBILE

CART

4'-0"

BE

NC

H

6' SHELVING6' SHELVING6' SHELVING

8 1/2"

4'-0"

TR

AS

H

BI

N

TR

AS

H

BI

N

TR

AS

H

BI

N 4' LONG

SHELVING

BENCH

MOBILE

CART

MOBILE

CART

MOBILE

CART

TR

AS

H

BI

N

TR

AS

H

BI

N

18'-5 1/2"

DIRTY SIDE

COMP. ST.

COMP. ST.

MOBILE

WORK

COUNTER

MOBILE

CART

MOBILE

CART

MOBILE

CART

MOBILE

CART

MOBILE

CART

MOBILE

CART

3'- 5"

4'- 8 1

/2"

3'- 2"

3'-2"

2'-

TRASH

BIN

3'-3 1/2"

6' SHELVING

2'- 7"

MOBILE

CART

MOBILE

CART

MOBILE

CART

4'-1"

5'

SH

EL

VI

NG

MOBILE

WORK

COUNTER

2'- 6"

3'- 9"

5'-0"

REF

REF

SPLASH GUARD

1'- 9 1

/2"

8'-3"

3'- 2"

4'-0"

4'- 1 1

/2"

PASS-THRU

SEE NOTE #3

LIGHT BOX

LOCATION

EXISTING WINDOW

TO BE TINTED

EXISTING WINDOW

TO BE TINTED

EXISTING WINDOW

TO BE TINTED

EXISTING WINDOW

TO BE TINTED

LIGHT BOX

LOCATION

SECURITY

INTELLI-KEY PAD

LOCATION

FIRE/SMOKE RATING

(SEE 3-AS-500 FOR

PARTITION LEGEND)

NOMINAL SIZE

SPECIFICATION

CATEGORY

SEQUENCE NUMBER

DOOR NUMBER

DOOR SIZE (SEE

3-AS-600 FOR DOOR

SIZE LEGEND)

VIEW NUMBER

SHEET NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW

NUMBER

SHEET

NUMBER

3-AS-000

# 3-AS-00

NEW WALL AND DOOR

EXISTING WALL AND

DOOR TO REMAIN

NEW DOOR TAG

NEW PARTITION TAG

NEW WALL

SECTION TAG

NEW DETAIL

CALLOUT TAG

NEW INTERIOR

ELEVATION TAG

3-AS-000

000 EQUIPMENT TAG

STERILE SIDE

ENTRY

EXISTING ENTRY

TO PHARMACY

DIRTY SIDE

2'- 7 1

/2" 3'-

0 1 /2"

8'- 2"

2'-11"

9"

14'-8 1/2" 4 1 /2"

1'- 7"

1'- 0 1

/2"

12'-0" 2'-8 1/2" 4'-4" 8'-11" 8'-4 1/2" 3'-5" 3'-8"

8 1/2"

2'-3 1/2"

10 1/2"

1'- 6"

2'- 2"

3'- 6 1

/2"

4 1 /2"

2'- 4"

3'-

1/ 2"

7'- 5"

1'- 8"

1'-6"

1'-6" 13'-2 1/2" 4'-4" 9'-0"

4'-11 1/2" 9 1/2"

5'-3 1/2" 6'-8 1/2"

8'- 0"

8'-6"

5 1 /2"

1'-11"

3'- 0"

8'- 0"

2'-0"8'-0"

3'-6" CLEAR OPENING

3'-8" CLEAR OPENING

3'-6" CLEAR OPENING

3'-6" CLEAR

OPENING

6'-10 1/2"

17'-1"

'-3

1/ 2"

V

IF

'-3

33'-8" 1'-5 1/2" 20'-2 1/2"

13'-6" 3'-3 1/2"

2'- 5"

5'- 0"

2'- 7 1

/2" 8'-

8"

4'-0 1/2"18'-9"

3'-0"

5'-

4'- 2 1

/2"

1'-4 1/2"

5'-2" 2'-5" 2'-10 1/2"

4 1 /2"

SIM

TYP

1'- 5 1

/2"

APPROX 24" HIGH CRAWL SPACE

NOTE: CUT/PATCH AND MODIFY AS

REQ'D FOR NEW PLUMBING WORK. DO

NOT DISTURB AREAS NEAR EXISTING

FOUNDATIONS/STRUCTURE.

STERILE SIDE

ENTRY

EXISTING ENTRY

TO PHARMACY

DIRTY SIDE

WALL MOUNTED FIRE

EXTINGUISHER

S

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

PROPOSED DIMENSION PLAN

PROPOSED FLOOR PLAN

PROPOSED REF. CLG. PLAN

1-AS-600

AREA OF EXISTING ROOF WHERE

CONTRACTOR IS TO REMOVE EXISTING

CURB AND RTU. AFTER REMOVAL, INSTALL

NEW METAL DECK, NEW INSULATION

(TAPERED) AND ROOFING TO MATCH

EXISTING.

AFTER REMOVAL OF EXISTING CURB;

CONTRACTOR TO PROVIDE AND INSTALL

NEW INFILL ROOF DECK CONSTRUCTION

WITH GALVANIZED CORRUGATED ROOF

DECK (MATCH EXISTING) AND 10" DP

COLD FORMED FRAMING (18 GA) TO

MATCH EXISTING. AREA OF NEW ROOF

DECK TO THEN BE REROOFED

(INSULATION, EPDM, FLASHING) AS REQ'D

TO MATCH EXISTING.

NOTE:

TYPICALLY INDICATES A NEW EXHAUST

DUCT PENETRATION (17 TOTAL)

CONTRACTOR TO PROVIDE AND INSTALL

NEW (12" HIGH MIN) SQUARE METAL CURB

(AND P.T. WOOD NAILERS AND BLOCKING AS

REQ'D) AND FULLY FLASH TO THE EXISTING

ROOF MEMBRANE. COORDINATE WITH

MECHANICAL DRAWINGS. PROVIDE WITH

FULLY SEALED STAINLESS STEEL CAP

FLASHING/COUNTER FLASHING.

NOTE:

CONTRACTOR TO PROVIDE AND INSTALL

NEW (12" HIGH MIN) SQUARE METAL CURB

FOR MECHANICAL UNITS (AND P.T. WOOD

NAILERS AND BLOCKING AS REQ'D) AND

FULLY FLASH TO THE EXISTING ROOF

MEMBRANE. COORDINATE WITH

MECHANICAL DRAWINGS. PROVIDE WITH

FULLY SEALED STAINLESS STEEL CAP

FLASHING/COUNTER FLASHING.

NOTE:

SEE MECHANICAL DRAWINGS FOR EXTENT

OF NEW DUCTWORK. CONTRACTOR TO

PROVIDE SEPARATION/PROTECTION

MEMBRANE UNDER ALL NEW SUPPORTS.

(TYPICAL)

MODIFY EXISTING ROOF, COORDINATE AS REQ'D.

NTS PROVIDE AT ALL PENTRATIONS

2 PIPE RAIL & VTR PENETRATION FLASHING DETAIL

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

PROPOSED ROOF PLAN

STERILE SIDE

ENTRY

EXISTING ENTRY

TO PHARMACY

DIRTY SIDE

L2280

R6060

M2080

L2280

R6060

R6060

R6060

R6060

M2080 M2080 M2080

M2080

M2080

M2080

M2

M2

F2

F2

F2

F2

F2

F2

F0

F0

F0535 K1910

M2

K1910

F0535

F0535 F0535

F0535 F0535

F0535

F0

F0

F0

F0535

P1965 A5075F0535

U1200

F0535F0535F0535

F0

F0

P2451

A1014U3500EXU3500EX

UCFRZ

A1014

UPE01A

UPE01A

A1014

A5145

P3000

CA040

A1014

A1014

UPE01

FURNITURE AND

EQUIPMENT BY VA

NEW WALL AND DOOR

EXISTING WALL AND

DOOR TO REMAIN

000 EQUIPMENT TAGPHARMACY EQUIPMENT SCHEDULE

EQUIPMENT LIST

JSN NAME AI QTY DESCRIPTION

A1014 WALL MOUNTED PHONE V/V 5 TELEPHONE, WALL MOUNTED, I LINE WITH SPEAKER

A5075 DISPENSER SOAP,

DISPOSABLE V/V 2

DISPOSABLE SOAP DISPENSER, ONE-HANDED

DISPENSING OPERATION. DESIGNED TO ACCOMMODATE

DISPOSABLE SOAP CARTRIDGE AND VALVE

A5077 DISPENSER, HAND

SANITIZER, HANDS-FREE V/V 6

A TOUCH FREE WALL-MOUNTED HAND SANITIZER

DISPENSE. DOES NOT INCLUDE SANITIZING LIQUID.

BATTERY OPERATED

A5100 SHOE COVER

DISPENSER, SMALL V/V 2 A SHOE COVER DISPENSER, THAT HOLDS UP TO 55 PAIRS

OF SHOE COVERS

A5145

HOOK, GARMENT,

DOUBLE, SS, SURFACE

MOUNTED

C/C 2

SURFACE MOUNTED, SATIN FINISH STAINLESS STEEL,

DOUBLE GARMENT HOOK, EQUIPPED WITH A CONCEALED

MOUNTING BRACKET THAT IS SECURED TO A CONCEALED

WALL PLATE

CA040

CABINET, OPEN, W/H, 2

SHELF, SLOPING

TOP38"X24"X13"

C/C 1

WALL OPEN OPEN FRONT CABINET, STAINLESS STEEL

CONSTRUCTION WITH SLOPED TOP AND TWO

ADJUSTABLE SHELVES

F0535 CART, UTILITY V/V 12 STAINLESS STEEL UTILITY CART, 40" HIGH X 36" WIDE X

24" DEEP WITH 4 HEAVY DUTY CASTER WHEELS

F2010 BASKET WASTE PAPER,

STEP ON V/V # STEP-ON WASTEPAPER BASKET WITH INNER LINER AND

FOOT PETAL ACTIVATED FLIP TOP, 36" X 15"

F2245

CAMERA, VIDEO

SURVEILLANCE, HD, IP

POWERED

V/V #

A HIGH DEFINITION, FULL FUNCTIONAL VIDEO

SURVEILLANCE CAMERA, CAPABLE OF FULL 1080P

RESOLUTION AT 30 FRAMES PER SECOND WHILE

OPTIMIZING NETWORK USAGE WITH H.264, MEPG-4 AND

JPEG COMPRESSION FORMATS.

M2080A

SHELVING STORAGE,

SOLID, STAINLESS STEEL

WITH ADJUSTABLE

SHELVES AND CASTERS

V/V 1 METRO SHELVING UNIT, SHELVES ARE SOLID STAINLESS

STEEL WITH CASTERS - 24" DEEP, 48" LONG, 60" HIGH

M2080B

SHELVING STORAGE,

SOLID, STAINLESS STEEL

WITH ADJUSTABLE

SHELVES AND CASTERS

V/V 6 METRO SHELVING UNIT, SHELVES ARE SOLID STAINLESS

STEEL WITH CASTERS - 24" DEEP, 72" LONG, 60" HIGH

M2080C

SHELVING STORAGE,

SOLID, STAINLESS STEEL

WITH ADJUSTABLE

SHELVES AND CASTERS

V/V 1 METRO SHELVING UNIT, SHELVES ARE SOLID STAINLESS

STEEL WITH CASTERS - 24" DEEP, 60" LONG, 60" HIGH

M2080D

SHELVING STORAGE,

SOLID, STAINLESS STEEL

WITH ADJUSTABLE

SHELVES AND CASTERS

V/V 1

METRO SHELVING UNIT, SHELVES ARE SOLID STAINLESS

STEEL WITH CASTERS - 30" DEEP, 60" LONG, 60" HIGH FOR

GARBING STORAGE

R6060

REFRIGERATOR,

BIOLOGICAL,SS,1 DOOR,

GLASS

V/V 5 MIGALI GSS-1RG, (INTERNAL VA NUMBER EE-104081)

2'-10"X2'-3"X6'-2"

P1965 EYEWASH/FACE, SINK

MOUNTED, HANDS FREE C/C 1

SINK MOUNTED EYEWASH STATION.WITH SOFT FLOW

DUAL FLOW HEADS.THE FLOW MUST BE ACTIVATED BY A

SINGLE MOMENTARY ACTION AND REMAIN ON UNTIL

TERMINATED, MODEL#

P2451

VALVE,

MIXING,THERMOSTATIC,

EYEWASH

C/C 1

EMERGENCY TEMPERING VALVE THERMOSTATICALLY

MIXES HOT AND COLD WATER TO PROVIDE A SAFE FLUID

SUPPLY FOR A SINGLE EMERGENCY EYE/FACE WASH

WITH A FLOW RATE OF 10 GPM, MODEL#

P3000

FULL SURGICAL TYPE

WASH SINK, KNEE

OPERATED

C/C 1 FULL SIZE, SURGICAL TYPE WASH SINK, SEE MEP

DRAWINGS

U0038G GLOVE DISPENSER V/V 4 PROTECTIVE GLOVE DISPENSER

U0038 PROTECTIVE

EQUIPMENT DISPENSER V/V 1 PERSONAL PROTECTIVE GEAR DISPENSER

UPE01 STAINLESS STEEL

FLOOR MOUNTED BENCH V/V 1 MOBILE STAINLESS STEEL BENCH, 24"X36", 16 GA,

CORNERS ARE TIG WELDED AND CLEANED, 18" HIGH

F035A NARROW SUPPLY CART V/V 3 STAINLESS STEEL UTILITY CART, 40" HIGH X 18" X 30"

WITH 4 HEAVY DUTY CASTER WHEELS

L2280

HOOD, LAMINAR FLOW,

HORIZONTAL, FREE

STANDING

V/C 2 VA TO PROVIDE 2 EXISTING HOODS APPROXIMATELY 6'X2',

FOR NON HAZARDOUS BUFFER ROOM, MODEL #BZ-6SSRX

U3500 BSE-CL-II V/V 0

NEGATIVE PRESSURE ISOLATOR OFFERING PRODUCT,

PERSONNEL AND ENVIRONMENT PROTECTION FROM

HAZARDOUS OR POTENT PHARMACEUTICAL COMPOUNDS

AND CHEMOTHERAPY AGENTS-CVE- LABGUARD ES

NU-813-300 BENCH TOP CLASS 1 CONTAINMENT

VENTILATED ENCLOSURE-54"HX29"X36"

U3500EX BSC V/V 2

NEGATIVE PRESSURE ISOLATOR OFFERING PRODUCT,

PERSONNEL AND ENVIRONMENT PROTECTION FROM

HAZARDOUS OR POTENT PHARMACEUTICAL COMPOUNDS

AND CHEMOTHERAPY AGENTS-VA TO USE THE TWO

EXISTING BSC HOODS - APPROX 6' X 2'

UPEO1A

STAINLESS STEEL

FLOOR MOUNTED

BENCH-SMALLER

V/V 1 MOBILE STAINLESS STEEL BENCH, 18"X30", 16 GA,

CORNERS ARE TIG WELDED AND CLEANED, 18" HIGH

F2010A CHEMO DOFFING TRASH

BIN V/V 1 36" X 15" TRASH BIN

LB1 LIGHT BOX V/V 2 WALL MOUNTED LIGHT BOX, "MODEL # TO BE PROVIDED

BY VA"

UCFRZ UNDERCOUNTER

FREEZER V/V 1 UNDERCOUNTER SMALL FREEZER, ACCUCOLD

MODEL #FS24LMED2

PRINTER COUNTER TOP TYPE

PRINTER V/V 2 ZEBRA "MODEL # TO BE PROVIDED BY VA"

U1200 PASS-THRU, VENTILATED C/C 1

SS PASS-THRU W/ INTERLOCKING SYSTEM TO MAINTIN

REQUIRED PRESSURIZATION AND MINIMIZE PARTICLE

MIGRATION; VENTED W/ HEPA FILTRATION MODEL

#CAP-18WHF-SST; 25Wx24Hx25D W/ HEPA FILTER AND

INTERLOCKS

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

EQUIPMENT SCHEDULE, AND

PROPOSED EQUIPMENT PLAN

7'- 8"

V.

I.F

3'-6"

CLEAR

L2280 L2280

F2010F0535F2010 F0535 F0535 F0535 F0535 F0535 F2010

EXISTING WINDOW

TO BE TINTED

F2010 F2010 F0535

F2010 F0535 F2010 F2010

R6060M2080

F0535 K1910

R6060 R6060 R6060

K1910

U3500EX U3500EX

U3500

4'-0"

CLEAR

EXISTING WINDOW

TO BE TINTED

4'-0"

CLEAR

3'-6"

CLEAR

3'-6"

CLEAR

F2010

R6060 R6060

F0535 F0535

M2080 M2080

P1965 A5075 P2451

P3000

LB1 LB1

2'-

2'-

2'-

2'-

S.S. COUNTERTOP

S.S. COUNTERTOP W/ HEAVY

DUTY S.S. BRACKETS

1-AS-400

1-AS-400

NOTE: APPLIED MYLAR SIGNAGE

(2" HIGH) TO READ "GARBING

REQUIRED PAST THIS POINT" TO

BE INSTALLED ON THE WALL.

U1200

SEE PLUMBING DRAWINGS

FOR SINK AT THIS LOCATION

NOTE: PAINTED (2" WIDE) RED LINE

ON WALL THAT ALIGNS WITH

FLOOR DEMARCATION LINE.

3'-6"

CLEAR

NEW SECURITY

INTELLI-KEY PAD

LOCATION EXISTING ELECTRICAL

PANELS

12X36 EAGLE STAINLESS STEEL

WALL SHELVING, MODEL#

WS1236TL; CONTRACTOR

FURNISHED, CONTRACTOR

INSTALLED

LINE OF CEILING. SEE REFLECTED CEILING PLAN

2'-

4"

16 GA 304 S.S. COUNTERTOP W/ 4" INTEGRATED

BACKSPLASH & MARINE EDGE. FORM TOPS, EDGES,

FLANGES AND BACKSPLASHES INTEGRALLY FROM

ONE SHEET OF STEEL. COUNTERTOP TO BE

CONSTRUCTED USING 16 GA STEEL HAT CHANNEL

REINFORCEMENT. FACTORY WELDS SHALL BE

GROUND AND POLISHED TO PROVIDE AN INVISIBLE

JOINT AND A #4 BRUSHED FINISH.

INTERSECTIONS B/W BACKSPLASH AND WORK

SURFACE SHALL BE RADIUSED A MINIMUM OF .375"

18" X 24" HEAVY DUTY S.S. WALL BRACKET CAPABLE

OF 450LBS/BRACKET MINIMUM

2'-0"

2'-6"

1'- 6"

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

INTERIOR ELEVATIONS

CASEWORK SECTIONS