36C24119R0074-0003001.pdf

PDF 5 MB Posted

Attached to
Project # 689-17-102 Inpatient Pharmacy IV Corrections
Solicitation number
36C24119R0074
Issued by

About this file

36C24119R0074 0003 S06 Drawings In-Patient Pharmacy IV 1 OF 3.pdf

View the file

Other files

File Type Posted
36C24119C0093-000.docx DOCX document
36C24119R0074-0007001.pdf PDF
36C24119R0074-0007000.docx DOCX document
36C24119R0074-0007001.pdf PDF
36C24119R0074-0007000.docx DOCX document
36C24119R0074-0006001.pdf PDF
36C24119R0074-0006000.docx DOCX document
36C24119R0074-0006002.pdf PDF
36C24119R0074-0006000.docx DOCX document
36C24119R0074-0006001.pdf PDF
36C24119R0074-0006002.pdf PDF
36C24119R0074-0005000.docx DOCX document
36C24119R0074-0005000.docx DOCX document
36C24119R0074-0004001.pdf PDF
36C24119R0074-0004000.docx DOCX document
36C24119R0074-0004001.pdf PDF
36C24119R0074-0004000.docx DOCX document
36C24119R0074-0003001.pdf PDF
36C24119R0074-0003003.pdf PDF
36C24119R0074-0003002.pdf PDF
36C24119R0074-0003000.docx DOCX document
36C24119R0074-0003003.pdf PDF
36C24119R0074-0003000.docx DOCX document
36C24119R0074-0003002.pdf PDF
36C24119R0074-0002000.docx DOCX document
36C24119R0074-0002000.docx DOCX document
36C24119R0074-0001000.docx DOCX document
36C24119R0074-0001000.docx DOCX document
36C24119R0074-003.pdf PDF
36C24119R0074-007.pdf PDF
36C24119R0074-004.pdf PDF
36C24119R0074-005.pdf PDF
36C24119R0074-006.pdf PDF
36C24119R0074-002.docx DOCX document
36C24119R0074-003.pdf PDF
36C24119R0074-006.pdf PDF
36C24119R0074-004.pdf PDF
36C24119R0074-005.pdf PDF
36C24119R0074-002.docx DOCX document
36C24119R0074-007.pdf PDF
36C24119R0074-001.docx DOCX document
36C24119R0074-001.docx DOCX document
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8.5

16A

35A

WEST SPRING STREET

36A

SHELTER

15A

SERVICE ROAD

SERVICE ROAD

2A

PET

LC1A

8.5

16A

35A

36A

15A

6A

2A

TS

TITLE SHEET WITH

INDEX TO DRAWINGS

SITE MAP

F i l e

N a m e

F

W e s t

H a v e n

P h a r m a c y

I V

T

S d w g

L a y o u t

T

S

D a t e

F r i

J u l

M

N a m e

F

E

C

A D

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% FOR BID

No. 25337

Q U I T R A N S T U L I T

B U S T IN E T

J O

H

D

F

E

L

L

E

N

Z E R E

N G

I

N

E

E

R

I N G

L L P

S

T

A

T

O

CO

N

E

C

T

I

C

U

T

P

R

O

F

E

S

S

I

O

A L

G

I

N

E

E

R

L

I

C

E N

S

FEC

A

D

B B B

B

B B

C

A A A

B

LB1

LB1

PRINTER

PRINTER

TUBE SYSTEMCO

UN

TE

R

EXAM

G206

EXAM

G205

VESTIBULE

G204

HIGH RISK

PHASE I

CONSTRUCTION

PHASE II

CONSTRUCTION

1-GI-001

ICRA PLAN & NOTES

NOTES:

PATIENT RISK GROUP FOR "TYPE D" CONSTRUCTION

LOW RISK GROUP

MEDIUM RISK GROUP

HIGH RISK GROUP

HIGHEST RISK GROUP Class IV

Class III / IV

Class IV Class IV

UL U465 (1 HOUR RATED)

FIRECODE 'X' GYPSUM BD PANELS

APPLIED VERTICALLY OR

HORIZONTALLY. HORIZONTAL JOINTS

NEED NOT BE STAGGERED. FACE

LAYER JOINTS TO BE FINISHED. FIRE

CAULK ALL PENETRATIONS.

CONSTRUCTION PARTITION WALL DETAIL

N.T.S.2

GROUND ICRA FLOOR PLAN1

F i l e

N a m e

F

W e s t

H a v a r m a c y

I V

G

I d a y o u t

G

I

D a t e

F r i

J u l a m e

F

E

C

A D

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% FOR BID

No. 25337

Q U I T R A N S T U L I T

B U S T IN E T

J O

L

L

E

N

Z E R E

N G

I

N

E

E

R

I N G

L L P

S

T

A

N

E

C

T

I

C

U

T

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

L

I

C

E N

S

E

PHASING NOTES:

1-GI-002

PARTIAL MECHANICAL

SITE PLAN

PARTIAL MECHANICAL SITE PLAN1

F i l e

N a m e

F

W e s t

H a v a r m a c y

I V

G

I d a y o u t

G

I

D a t e

F r i

J u l a m e

F

E

C

A D

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% FOR BID

No. 25337

Q U I T R A N S T U L I T

B U S T IN E T

J O

L

L

E

N

Z E R E

N G

I

N

E

E

R

I N G

L L P

S

T

A

N

E

C

T

I

C

U

T

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

L

I

C

E N

S

E

D

TYPICAL CHAIN LINK FENCE AND GATE2

KEYED NOTES:

SECTION VIEW

TYPICAL GRAVEL SURFACACE3

9-4-2b

W#

3-AS-000

3-AS-000

3-AS-000

3-AS-000

3-AS-000

FIRE/SMOKE RATING (SEE

3-AS-500 FOR PARTITION

LEGEND)

NOMINAL SIZE

SPECIFICATION CATEGORY

SEQUENCE NUMBER

DOOR NUMBER

DOOR SIZE (SEE 3-AS-600

FOR DOOR SIZE LEGEND)

VIEW NUMBER

SHEET NUMBER

VIEW NUMBER

SHEET NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW NUMBER

SHEET NUMBER

F i l e

N a m e

C

U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h

V

A

W e s t

H a v

C o m p o u n d i n g

I V

S u i t e F l o o r P l a n d a y o u t

A

S

D a t e

W e d

J a a m e l s c h l e m o w i t z

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

ARCHITECTURAL: SYMBOLS,

ABBREVIATIONS AND NOTES

1-AS-001

AutoCAD SHX Text GENERAL NOTES: 1. IN THE EVENT OF INCONSISTENCIES WITHIN OR BETWEEN PARTS OF THE CONTRACT IN THE EVENT OF INCONSISTENCIES WITHIN OR BETWEEN PARTS OF THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE STANDARDS, CODES AND ORDINANCES, THE CONTRACTOR SHALL: (1) PROVIDE THE BETTER QUALITY OR GREATER QUANTITY OF WORK OR (2) COMPLY WITH THE MORE STRINGENT REQUIREMENT; EITHER OR BOTH IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. 2. VERIFY ALL DIMENSIONS IN FIELD FOR FIT OF UNITS SPECIFIED. MODIFY VERIFY ALL DIMENSIONS IN FIELD FOR FIT OF UNITS SPECIFIED. MODIFY DIMENSIONS ON SHOP DRAWING AS REQUIRED, PRIOR TO SUBMITTAL OR RELEASE FOR PURCHASE OR FABRICATION. 3. ALL ARCHITECTURAL CASEWORK & WOODWORK IS TO BE INSTALLED ON TOP OF ALL ARCHITECTURAL CASEWORK & WOODWORK IS TO BE INSTALLED ON TOP OF NEW FLOOR FINISHES. (CARPET, SHEET VINYL., ETC.) 4. THE DESIGN OF THE PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL THE DESIGN OF THE PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 5. CONTRACTORS SHALL VERIFY & ASSUME RESPONSIBILITY FOR VERIFYING ALL CONTRACTORS SHALL VERIFY & ASSUME RESPONSIBILITY FOR VERIFYING ALL EXISTING OR AS-BUILT CONDITIONS AND INCLUDE INFORMATION IN SHOP DRAWINGS PRIOR TO SUBMITTAL TO A & E. 6. EACH CONTRACTOR TO BE RESPONSIBLE FOR APPLIED FINISHES FOR THEIR WORK. EACH CONTRACTOR TO BE RESPONSIBLE FOR APPLIED FINISHES FOR THEIR WORK. 7. IN AREA OF WORK EACH CONTRACTOR TO BE RESPONSIBLE FOR ALL ADJACENT IN AREA OF WORK EACH CONTRACTOR TO BE RESPONSIBLE FOR ALL ADJACENT FINISHED WORK OF OTHER TRADES. EACH CONTRACTOR IS TO PROTECT HIS OWN WORK. 8. ALL CONTRACTORS ARE TO COORDINATE THEIR WORK IN ACCORDANCE WITH ALL CONTRACTORS ARE TO COORDINATE THEIR WORK IN ACCORDANCE WITH DRAWINGS. 9. ALL PENETRATIONS THROUGH RATED WALLS & CORRIDOR WALLS ARE TO BE ALL PENETRATIONS THROUGH RATED WALLS & CORRIDOR WALLS ARE TO BE FIRE-STOPPED BY TRADE MAKING PENETRATION, WITH APPROVED MATERIALS PER DRAWINGS AND SPECIFICATIONS. 10. ALL DIMENSIONS SHOWN ON DRAWINGS ARE SUBJECT TO VERIFICATION OF ACTUAL ALL DIMENSIONS SHOWN ON DRAWINGS ARE SUBJECT TO VERIFICATION OF ACTUAL DIMENSIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD TO INSURE PROPER AND ACCURATE FIT OF MATERIALS AND ITEMS TO BE INSTALLED. 11. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER AND THE INFORMATION FURNISHED BY THE OWNER, AND SHALL AT ONCE REPORT TO THE ARCHITECT ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED. THE CONTRACTOR SHALL NOT BE LIABLE TO THE OWNER, OR ARCHITECT FOR DAMAGE RESULTING FROM ERRORS, INCONSISTENCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS UNLESS THE CONTRACTOR RECOGNIZED SUCH ERROR, INCONSISTENCY OR OMISSION AND KNOWINGLY FAILED TO REPORT IT TO THE ARCHITECT. IF THE CONTRACTOR PERFORMS ANY CONSTRUCTION ACTIVITY KNOWING IT INVOLVES A RECOGNIZED ERROR, INCONSISTENCY OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT SUCH NOTICE TO THE ARCHITECT, THE CONTRACTOR SHALL ASSUME APPROPRIATE RESPONSIBILITY FOR SUCH PERFORMANCE AND SHALL BEAR AN APPROPRIATE AMOUNT OF THE ATTRIBUTABLE COSTS FOR CORRECTION. 12. WHENEVER THE DRAWINGS SHOW EXISTING CONSTRUCTION, REQUIRED AS PART OF WHENEVER THE DRAWINGS SHOW EXISTING CONSTRUCTION, REQUIRED AS PART OF THE WORK OR NOT, IT IS UNDERSTOOD THAT IT IS SHOWN AS A MATTER OF INFORMATION TO BE SUBSTANTIALLY CORRECT. THE OWNER ASSUMES NO RESPONSIBILITY THEREFORE. THE CONTRACTOR SHALL MAKE ITSELF TOTALLY FAMILIAR WITH ALL EXISTING CONDITIONS AFFECTING THE NATURE AND MANNER OF CONDUCTING THEIR WORK. ANY ERRORS DUE TO THE CONTRACTOR'S FAILURE TO VERIFY ALL GRADES, ELEVATIONS, LOCATIONS, OR DIMENSIONS SHALL BE PROMPTLY RECTIFIED BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO THE OWNER. 13. WHERE EQUIPMENT LINES OR PIPING AND/OR CONDUIT ARE SHOWN WHERE EQUIPMENT LINES OR PIPING AND/OR CONDUIT ARE SHOWN DIAGRAMMATICALLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND ORDERLY ARRANGEMENT OF THE VARIOUS LINES OF PIPING AND CONDUIT INCLUDED IN THE WORK OF HIS CONTRACT. HE SHALL COORDINATE THE WORK OF SEVERAL CONTRACTORS AND PREVENT ALL INTERFERENCE'S BETWEEN EQUIPMENT, LINES OF PIPING, ARCHITECTURAL FEATURES, AND AVOID ANY UNSIGHTLY ARRANGEMENTS IN THE EXPOSED AREAS. 14. ALL WORK SHALL BE EXECUTED IN A THOROUGH, SUBSTANTIAL, WORKMANLIKE ALL WORK SHALL BE EXECUTED IN A THOROUGH, SUBSTANTIAL, WORKMANLIKE MANNER, IN COMPLETE ACCORDANCE WITH THE MANUFACTURER'S MOST RECENT RECOMMENDATIONS UNLESS OTHERWISE SPECIFIED OR PERMITTED BY THE ARCHITECT.

AutoCAD SHX Text HEALTH & SAFETY GENERAL NOTES: HEALTH & SAFETY GENERAL NOTES: 1. ALL EXISTING EXIT DOORS ARE REQUIRED TO BE KEPT CLEAR AT ALL ALL EXISTING EXIT DOORS ARE REQUIRED TO BE KEPT CLEAR AT ALL TIMES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF CHEMICAL FUMES, GASES, AND OTHER CONTAMINATES PRODUCED BY WELDING, GASOLINE OR DIESEL ENGINES, ROOFING, PAVING, PAINTING, ETC., TO ENSURE THEY DO NOT ENTER OCCUPIED PORTIONS OF THE BUILDING OR AIR INTAKES. 3. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ACTIVITIES THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ACTIVITIES AND MATERIALS WHICH RESULT IN "OFF-GASSING" OF VOLATILE ORGANIC COMPOUNDS SUCH AS GLUES, PAINTS, FURNITURE, CARPETING, WALL COVERING, DRAPERY, ETC., ARE SCHEDULED, CURED OR VENTILATED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS BEFORE A SPACE CAN BE OCCUPIED. DOORS & FRAMES 1. CENTER LINE OF ALL PANIC DEVICES. PUSH BARS SHALL BE 38" (3'-2") CENTER LINE OF ALL PANIC DEVICES. PUSH BARS SHALL BE 38" (3'-2") ABOVE FINISHED FLOOR (MAX. VERIFY WITH VA) 2. CLEAN AND CAULK THE FULL PERIMETER OF ALL GLASS, FRAMES, AND CLEAN AND CAULK THE FULL PERIMETER OF ALL GLASS, FRAMES, AND PANEL EDGES OF NEW FRAMES AND LITES AS PER SPECIFICATIONS. 3. ALL NEW FRAMES IN GYPSUM BOARD PARTITIONS TO HAVE THREE (3) ALL NEW FRAMES IN GYPSUM BOARD PARTITIONS TO HAVE THREE (3) ANCHORS PER JAMB MINIMUM INTO STUD AND FRAME. 4. ALL DOOR FRAMES SHALL BE PROVIDED WITH SILENCERS. ALL DOOR FRAMES SHALL BE PROVIDED WITH SILENCERS. 5. EXTERIOR METAL DOORS AND FRAMES ARE TO BE INSULATED. EXTERIOR METAL DOORS AND FRAMES ARE TO BE INSULATED. PLUMBING 1. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL NEW PLUMBING PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL NEW PLUMBING FIXTURES AS INDICATED (SEE PLANS, SPEC, AND SCHEDULE) WITH ALL REQUIRED PIPING, TRAPS, VENTING, CLEANOUTS, ETC., AS SHOWN OR AS REQUIRED PER CODE. 2. ALL EXPOSED PIPING BELOW NEW SINKS/LAVATORIES ARE TO BE ALL EXPOSED PIPING BELOW NEW SINKS/LAVATORIES ARE TO BE INSULATED/PROTECTED TO MEET ALL ADA REQUIREMENTS. 3. PLUMBING CONTRACTOR TO COORDINATE HIS WORK IN SPECIAL ROOMS PLUMBING CONTRACTOR TO COORDINATE HIS WORK IN SPECIAL ROOMS WITH CASEWORK ROUGH-IN REQUIREMENTS OF THAT TRADE AND TO COORDINATE HIS WORK IN STARBUCKS AREA WITH ROUGH-IN REQUIREMENTS. ARCHITECTURAL CASEWORK & EQUIPMENT 1. GENERAL CONTRACTOR IS TO PROVIDE ALL ROUGH-IN INFORMATION ON GENERAL CONTRACTOR IS TO PROVIDE ALL ROUGH-IN INFORMATION ON SHOPS (LOCATION & SIZE) SO AS NOT TO DELAY THE WORK OF OTHER TRADES. THE WORK OF OTHER TRADES IS BUILT INTO THE STRUCTURE, CASEWORK SHOPS MUST BE SUBMITTED AND APPROVED PRIOR TO ERECTION OF STRUCTURE. 2. ALL CABINET DOORS AND DRAWERS TO HAVE LOCKS EXCEPT SINK ALL CABINET DOORS AND DRAWERS TO HAVE LOCKS EXCEPT SINK CABINETS. CABINET LOCKS IN ALL ROOMS TO BE KEYED ALIKE IN EACH ROOM AND DIFFERENTLY FROM OTHER ROOMS. 3. GENERAL CONTRACTOR SHALL INSTALL ALL ARCHITECTURAL CASEWORK GENERAL CONTRACTOR SHALL INSTALL ALL ARCHITECTURAL CASEWORK FOR ALL ROOMS SHOWN ON PLANS OR CALLED FOR IN SCHEDULES. INSTALL ALL TOPS, BACK SPLASHES, FILLERS, BLOCKING, ETC. 4. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PIPE CHASES OR GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PIPE CHASES OR OTHER OBSTRUCTIONS IN FIELD FOR PROPER INSTALLATION OF CABINETWORK AND ALTER WORK AS NECESSARY FOR PROPER FIT. 5. GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL GROMMETS AS GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL GROMMETS AS REQUIRED TO ALLOW ACCESS TO ALL POWER, DATA AND COMMUNICATION RECEPTACLES. 6. PROVIDE AND INSTALL NEW CONCEALED, FIRE RETARDANT BLOCKING AT PROVIDE AND INSTALL NEW CONCEALED, FIRE RETARDANT BLOCKING AT ALL NEW ACCESSORIES/CASEWORK AS REQUIRED.

AutoCAD SHX Text

NEW WALL AND DOOR

AutoCAD SHX Text

EXISTING WALL AND DOOR TO REMAIN

AutoCAD SHX Text N#

AutoCAD SHX Text X

AutoCAD SHX Text

NEW WINDOW/ STOREFRONT TAG

AutoCAD SHX Text

NEW DOOR TAG

AutoCAD SHX Text

NEW PARTITION TAG

AutoCAD SHX Text

NEW EXTERIOR ELEVATION TAG

AutoCAD SHX Text

NEW WALL SECTION TAG

AutoCAD SHX Text

NEW BUILDING SECTION TAG

AutoCAD SHX Text

NEW INTERIOR ELEVATION TAG

AutoCAD SHX Text

NEW DETAIL CALLOUT TAG

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text

AutoCAD SHX Text Revisions

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Date

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VAMC, WEST HAVEN, CT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Approved: Project Manager

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Service Chief

AutoCAD SHX Text Project Title

AutoCAD SHX Text Location

AutoCAD SHX Text Building Number

AutoCAD SHX Text

VAMC, WEST HAVEN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Project No.

AutoCAD SHX Text Date

AutoCAD SHX Text Drawn

AutoCAD SHX Text Checked

AutoCAD SHX Text

VA

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text Department of

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text A

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-11-19

AutoCAD SHX Text 689-17-002

AutoCAD SHX Text

VA

AutoCAD SHX Text

WEST HAVEN, CT

AutoCAD SHX Text

INPATIENT PHARMACY IV

AutoCAD SHX Text

CONNECTICUT

AutoCAD SHX Text

HEALTHCARE

AutoCAD SHX Text

SYSTEM

AutoCAD SHX Text

VA

AutoCAD SHX Text

STAMP:

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

AutoCAD SHX Text

CORRECTIONS

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

CT PROFESSIONAL ENGINEER NO. 25337

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

AREA OF WORK FIRST FLOOR BLDG 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

* BRICK

AutoCAD SHX Text

* EXISTING TO BE REMOVED

AutoCAD SHX Text

* NEW STUD WALLS

AutoCAD SHX Text

* EXISTING TO REMAIN

AutoCAD SHX Text

* EARTH

AutoCAD SHX Text

* POUROUS FILL

AutoCAD SHX Text

* METAL / STEEL

AutoCAD SHX Text

* INSULATION

AutoCAD SHX Text

* WOOD

AutoCAD SHX Text

* SPLIT FACE CONCRETE BLOCK

AutoCAD SHX Text

* CONCRETE

AutoCAD SHX Text

MATERIALS

AutoCAD SHX Text

PARTITIONS (PLAN)

AutoCAD SHX Text 1.) THE CONTRACTOR IS TO VISIT THE SITE AND THOROUGHLY ACQUAINT HIMSELF WITH ALL EXIST. CONDITIONS TO CHECK AND VERIFY ALL CONDITIONS, DIMENSIONS, ETC. AND REPORT TO THE ARCHITECT ANY ERRORS, OMISSIONS OR VARIATION FROM INTENT OF THE PLANS PRIOR TO THE START OF WORK. 2.) NO DRAWINGS ARE TO BE SCALED: USE DIMENSIONS ONLY OR VERIFY ALL CONDITIONS IN FIELD. 3.) THOSE ITEMS NOT NOTED, BUT IMPLIED AS NECESSARY FOR THE PERFORMANCE OF THE CONTRACT ARE CONSIDERED PART OF THE WORK. 4.) ALL MATERIAL AND WORKMANSHIP IS TO BE GUARANTEED BY THE CONTRACTOR TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR, THE CONTRACTOR AGREES TO CORRECT WITHOUT CHARGE SUCH CONDITIONS AS MAY OCCUR DURING THE GUARANTEE PERIOD. 5.) ALL WORK IS TO BE EXECUTED BY MECHANICS SKILLED IN THEIR TRADES. 6.) ALL CHANGES AND OR SUBSTITUTIONS ARE TO BE APPROVED IN WRITING BEFORE BEING INCORPORATED INTO THE WORK. 7.) ALL TRADES TO COOPERATE WITH EACH OTHER TO FACILITATE THE PROGRESS OF THE ENTIRE JOB. 8.) CONTRACTOR IS TO PROTECT THE PUBLIC AND PREMISES DURING THE PERIOD OF CONSTRUCTION WITH ADEQUATE SHORING, BRACING, FENCING, LIGHTING, ETC. . 9.) CONTRACTOR IS TO REMOVE ALL RUBBISH FROM THE SITE ON A DAILY BASIS (AS PER ICRA AND VA GUIDELINES) RESULTING FROM HIS WORK DURING THE PROGRESS OF CONSTRUCTION AND SHALL LEAVE THE PREMISES IN A CONDITION SATISFACTORY TO THE OWNER PRIOR TO THE FINAL INSPECTION. 10.) ALL MATERIALS, ASSEMBLIES, CONSTRUCTION AND EQUIPMENT SHALL CONFORM TO THE REGULATIONS OF THE INTERNATIONAL BUILDING CODE AND SHALL CONFORM TO GENERALLY ACCEPTED STANDARDS.

AutoCAD SHX Text A.B. ANCHOR BOLT ANCHOR BOLT AC ACOUSTICAL ACOUSTICAL ACT ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE ADJ ADJACENT ADJACENT AFF ABOVE FINISH FLOOR ABOVE FINISH FLOOR ALUM ALUMINUM ALUMINUM ANOD ANODIZED ANODIZED A.P. ACCESS PANEL ACCESS PANEL ARCH ARCHITECT ARCHITECT ASPH ASPHALT ASPHALT APPROX APPROXIMATE APPROXIMATE @ AT AT BLDG BUILDING BUILDING BLK BLOCK BLOCK BOT BOTTOM BOTTOM B/O BOTTOM OF BOTTOM OF BRK BRICK BRICK CBL CONCRETE BLOCK CONCRETE BLOCK CLG CEILING CEILING C.T. CERAMIC TILE CERAMIC TILE CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT CONC CONCRETE CONCRETE CONT CONTINUOUS CONTINUOUS C.J. CONTROL JOINT CONTROL JOINT CENTERLINE CB CATCH BASIN CATCH BASIN DIA./ DIAMETER DN DOWN DOWN DR DRAIN DRAIN DWG DRAWING DRAWING ELEC ELECTRIC ELECTRIC EL/ELEV ELEVATION ELEVATION EQUIP EQUIPMENT EQUIPMENT EXIST EXISTING EXISTING EXP JT EXPANSION JOINT EXPANSION JOINT EXT EXTERIOREXTERIOR

AutoCAD SHX Text FIN FINISH FINISH FIN FL FINISHED FLOOR FINISHED FLOOR FD FLOOR DRAIN FLOOR DRAIN FGL FIBERGLASS FIBERGLASS FL FLOOR FLOOR GA GAGE/GAUGE GAGE/GAUGE GALV GALVANIZED GALVANIZED GC GENERAL CONTRACTOR GENERAL CONTRACTOR GL GLASS GLASS GWB GYPSUM WALL BD GYPSUM WALL BD HC HUNG CEILING HUNG CEILING HDW HARDWARE HARDWARE HM HOLLOW METAL HOLLOW METAL HOR HORIZONTAL HORIZONTAL HP HIGH POINT HIGH POINT H+V HEATING AND VENTILATION HEATING AND VENTILATION INSUL INSULATION INSULATION JAN JANITOR JANITOR JT JOINT JOINT LAM LAMINATE LAMINATE MAS MASONRY MASONRY MATL MATERIAL MATERIAL MECH MECHANICAL MECHANICAL MIN MIN MIN M.O. MASONRY OPENING MASONRY OPENING MAX MAXIMUM MAXIMUM MTL METAL METAL N.I.C. NOT IN CONTRACT NOT IN CONTRACT NTS NOT TO SCALE NOT TO SCALE NO. NUMBER NUMBER OPNG OPENING OPENING O.C. ON CENTERON CENTER

AutoCAD SHX Text PARTN PARTITION PARTITION P+D PLUMBING AND DRAINAGE PLUMBING AND DRAINAGE POLY POLYURETHANE POLYURETHANE PROPERTY LINE PT PRESSURE TREATED PRESSURE TREATED PTD PAINTED PAINTED R RISER OR RADIUS RISER OR RADIUS RDL ROOF DRAIN LEADER ROOF DRAIN LEADER REINF REINFORCED REINFORCED REQD REQUIRED REQUIRED RM ROOM ROOM SC SOLID CORE SOLID CORE SECT SECTION SECTION SIM SIMILAR SIMILAR SPEC SPECIFICATION SPECIFICATION STL STEEL STEEL SAD SADDLE SADDLE STOR STORAGE STORAGE T TREAD OR TOP TREAD OR TOP TEL TELEPHONE TELEPHONE T&G TONGUE AND GROOVE TONGUE AND GROOVE THK THICK THICK T/O TOP OF TOP OF TW TOP OF WALL TOP OF WALL TYP TYPICAL TYPICAL VB VAPOR BARRIER VAPOR BARRIER VERT VERTICAL VERTICAL W WIDE WIDE WH WEEP HOLE WEEP HOLE WST WAINSCOT WAINSCOT WWF WELDED WIRE FABRIC WELDED WIRE FABRIC W/ WITH WITH WD WOODWOOD

AutoCAD SHX Text

ABBREVIATIONS (U.N.O.) (U.N.O.)

AutoCAD SHX Text

GENERAL SPECIFICATION NOTES

AutoCAD SHX Text

SYMBOLS LEGEND

AutoCAD SHX Text

GENERAL NOTES

20" HIGH CRAWL SPACE AREA, V.I.F.

FIRE/SMOKE RATING

(SEE 3-AS-500 FOR

PARTITION LEGEND)

NOMINAL SIZE

SPECIFICATION

CATEGORY

SEQUENCE NUMBER

DOOR NUMBER

DOOR SIZE (SEE

3-AS-600 FOR DOOR

SIZE LEGEND)

VIEW NUMBER

SHEET NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW

NUMBER

SHEET

NUMBER

x-x-xx

3-AS-000

3-AS-00

NEW WALL AND DOOR

EXISTING WALL AND

DOOR TO REMAIN

NEW DOOR TAG

NEW PARTITION TAG

NEW WALL

SECTION TAG

NEW DETAIL

CALLOUT TAG

NEW INTERIOR

ELEVATION TAG

3-AS-000

000 EQUIPMENT TAG

F i l e

N a m e

C

U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h

V

A

W e s t

H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t

A

S E

D a t e

W e d

J a m e l s c h l e m o w i t z

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

EXISTING FLOOR PLAN

EXISTING CRAWL SPACE

AND ROOF PLAN

1-AS-E100

AutoCAD SHX Text

CHEMO ROOM

AutoCAD SHX Text

ANTE ROOM

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

CLEAN PREP.

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

HAC

AutoCAD SHX Text

MOP SINK

AutoCAD SHX Text N#

AutoCAD SHX Text X

AutoCAD SHX Text

FLOOR PLAN LEGEND

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text

AutoCAD SHX Text Revisions

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Date

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VAMC, WEST HAVEN, CT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Approved: Project Manager

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Service Chief

AutoCAD SHX Text Project Title

AutoCAD SHX Text Location

AutoCAD SHX Text Building Number

AutoCAD SHX Text

VAMC, WEST HAVEN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Project No.

AutoCAD SHX Text Date

AutoCAD SHX Text Drawn

AutoCAD SHX Text Checked

AutoCAD SHX Text

VA

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text Department of

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text A

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-11-19

AutoCAD SHX Text 689-17-002

AutoCAD SHX Text

VA

AutoCAD SHX Text

WEST HAVEN, CT

AutoCAD SHX Text

INPATIENT PHARMACY IV

AutoCAD SHX Text

CONNECTICUT

AutoCAD SHX Text

HEALTHCARE

AutoCAD SHX Text

SYSTEM

AutoCAD SHX Text

VA

AutoCAD SHX Text

STAMP:

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

AutoCAD SHX Text

CORRECTIONS

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

CT PROFESSIONAL ENGINEER NO. 25337

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

AREA OF WORK FIRST FLOOR BLDG 1

AutoCAD SHX Text

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING PLAN - CRAWL SPACE

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING FLOOR PLAN - GROUND FLOOR

AutoCAD SHX Text

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

ROOF PLAN - EXISTING

2 22

PHASE I

PARTITION TO

REMAIN DURING

PHASE II. PHASE II ENTRY.

PHASE I ENTRYREMOVE WINDOW, CUT & PATCH WALL FOR TEMPORARY

PHASE I ENTRY. WINDOW TO BE REINSTALLED AND WALL TO

BE RECONSTRUCTED AT END OF PHASE I. (SEE NOTE #16)

PHASE II

PARTITION

PHASE I

PARTITION

PHASE I

PARTITION

PHASE II

INTERIOR

WORK AREA

PHASE I

INTERIOR

WORK AREA19

PHASE II ENTRY.

PHASE II ENTRY: CUT &

PATCH EXTERIOR WALL

FOR TEMPORARY PHASE II

ENTRY (SIMILAR TO NOTE

#16, EXCEPT - SINGLE

3'-0"x 6'-8" HOLLOW METAL

DOOR & FRAME)

PHASE I

PARTITION TO

REMAIN DURING

PHASE II. PHASE II ENTRY.

PHASE I ENTRY

PHASE II

PARTITION

PHASE I

PARTITION

PHASE I

PARTITION

PHASE II

INTERIOR

WORK AREA

PHASE I

INTERIOR

WORK AREA

PHASE II ENTRY.

1. DRAWING SHOWS GENERAL EXTENT OF DEMOLITION AND

REMOVALS. THE CONTRACTOR SHALL MAKE ALL REMOVAL

AS REQUIRED TO PROPERLY INSTALL ALL NEW WORK. SEE

PHASING/ICRA.

2.DEMOLITION AND REMOVALS SHALL BE PERFORMED SO

THAT EXISTING FINISHES, EQUIPMENT, AND SYSTEMS THAT

ARE TO REMAIN ARE NOT DAMAGED. PROVIDE PROTECTION

AS NEEDED TO ENSURE THAT THESE ITEMS ARE NOT

DAMAGED.

3.SEE MEP DRAWINGS FOR THOSE REMOVALS. ALL

ABANDONED WIRING, PIPING AND EQUIPMENT SHALL BE

REMOVED EXCEPT THOSE IN EXISTING WALL AND SLABS

THAT ARE TO REMAIN. PROPERLY CAP AND/OR TERMINATE

ABANDONED PIPING AND WIRING THAT REMAINS.

4.ERECT NEW TEMPORARY PARTITIONS UP TO DECK ABOVE AS

REQUIRED BY NFPA 241, SECTION 8.6.2.1 WITH A MINIMUM OF

1-HOUR RATING AND SMOKE TIGHT. COMPLY WITH THE JOINT

COMMISSIONS STANDARDS AND AS REQUIRED TO PROTECT

ADJACENT SPACES FROM DUST MIGRATION. PROVIDE AND

INSTALL RATED (45MIN) AND SEALED ACCESS DOORS AS

REQUIRED FOR STAGING AND PHASING, COMPLETE WITH ALL

REQUIRED HARDWARE AND CLOSURES. ALL EXISTING

PENETRATIONS TO BE SEALED AND TEMPORARY FIRE/SMOKE

DAMPERS INSTALLED AT ALL DUCT PENETRATIONS AT LINE

OF NEW TEMPORARY WALL. CUT AND PATCH AS REQUIRED

ALL EXISTING FINISHES TO INSTALL NEW TEMPORARY

CONSTRUCTION SEPARATION WALLS. CONTRACTOR TO

PATCH AND REPAIR ALL EXISTING

SURFACES/FINISHES/CONSTRUCTION AS REQUIRED WHEN

TEMPORARY WALLS ARE REMOVED AT COMPLETION OF

PROJECT. COORDINATE WITH PHASING/ICRA DRAWINGS TO BE

MINIMUM OF STC 50 RATING.

5.GENERAL CONTRACTOR IS TO NOTIFY THE ARCHITECT/VA

IMMEDIATELY FOLLOWING FINDING PIPING, CHASES,

DUCTWORK, ETC. WITHIN THE WALLS TO BE DEMOLISHED

THAT WILL CAUSE CHANGE IN DESIGN.

6. ALL CONSTRUCTION DEBRIS TO BE REMOVED AFTER 5PM IF

USING ELEVATOR. ALL DEBRIS SHALL BE REMOVED IN A

COVERED BUGGY. COORDINATE WITH C.O.R. AND REFER TO

PHASING/ICRA DRAWING FOR ADDITIONAL INFORMATION.

7.USE OF A JACK HAMMER IS NOT PERMITTED.

8.COORDINATE WITH VA C.O.R. FOR AFTER HOURS WORK FOR

ALL NOISY (HIGH DECIBEL) WORK.

9.COORDINATE WITH VA C.O.R. FOR AFTER HOURS WORK TO

REMOVE EXISTING MATERIALS; USE OF A JACK HAMMER IS

NOT PERMITTED.

10. COORDINATE ALL DEMOLITION WORK WITH ASBESTOS

ABATEMENT WORK.

11. ALL WALL MOUNTED POSTERS, POSTER BOARDS,

ARTWORK, PHOTOGRAPHS AND SIGNAGE TO BE CAREFULLY

REMOVED AND RETURNED TO THE VA C.O.R. FOR RE-USE.

DEMOLITION NOTES

DEMOLITION PLAN LEGEND

EXISTING PARTITION

TO BE DEMOLISHED

EXISTING DOOR TO

BE DEMOLISHED

EXISTING PARTITION

TO REMAIN

EXISTING DOOR

TO REMAIN

F i l e

N a m e

C

U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h

V

A

W e s t

H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t

A

S D

D a t e

W e d

J a m e l s c h l e m o w i t z

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

DEMOLITION PLAN

DEMOLITION CEILING PLAN

1-AS-D100

DEMOLITION KEYNOTES

Number Note

1 TEMPORARY PARTITIONS, SEE GENERAL DEMOLITION NOTE #4.

REMOVE EXISTING INTERIOR PARTITION COMPLETE. CUT, PATCH

AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED FOR

SURFACES TO BE FLUSH & MATCH EXISTING.

CONTRACTOR TO REMOVE EXISTING EQUIPMENT. BSC

CABINETS, LAMINAR FLOW HOODS TO BE REUSED IN THE NEW

FLOOR PLAN, COORDINATE AS REQUIRED.

REMOVE EXISTING FLOORING AND CLEAN AND PREP FOR NEW

FLOORING. CUT, PATCH AND REPAIR ADJACENT FINISHES TO

REMAIN AS REQUIRED.

REMOVE EXISTING CEILING SYSTEM COMPLETELY. CUT, PATCH

AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED.

REMOVE EXISTING DOOR AND FRAME COMPLETE. CUT, PATCH

AND REPAIR ADJACENT FINISHES AS REQUIRED.

CONTRACTOR TO REMOVE EXISTING EQUIPMENT AND PROVIDE

TO VA.

REMOVE EXISTING WINDOW AND FRAME COMPLETE. CUT, PATCH

AND REPAIR ADJACENT FINISHES AS REQUIRED. SEE FLOOR PLAN

FOR AREAS TO RECEIVE NEW INFILL FRAMING AND PREPARE

OPENING TO RECEIVE NEW INFILL. INFILL TO BE FLUSH WITH

EXISTING WALL.

REMOVE EXISTING PLUMBING FIXTURES COMPLETE AND CAP OFF

ALL LINES. CUT, PATCH AND REPAIR ADJACENT FINISHES TO

REMAIN AS REQUIRED.

REMOVE EXISTING COUNTER/WALL CASEWORK AND LOCKERS

COMPLETE. PATCH AND REPAIR ADJACENT FINISHES AS REQUIRED.

REMOVE EXISTING CEILING SYSTEM AND INSTALL NEW CEILING

SYSTEM AS REQUIRED TO INSTALL NEW MEP WORK. CUT, PATCH

AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED.

REMOVE EXISTING FRAMED WALL AND GYPSUM BOARD FINISH.

EXISTING MECHANICAL UNITS TO BE REMOVED. SEE MEP

DRAWINGS. TYPICAL.

REMOVE EXISTING WINDOW COMPLETE. PREPARE SURFACE TO

RECEIVE NEW WINDOW.

SYMBOL

"CONTRACTOR TO INSTALL NEW TEMPORARY PAINTED HOLLOW

MTL FRAME AND DOOR PAIR (CLEAR OPENING OF AT LEAST 6'x

HEIGHT OF EXIST WINDOW FRAME, V.I.F) FOR PHASE I ENTRY

FROM THE EXTERIOR AS LOCATED ON DRAWING 1-AS-D100. THIS

PAIR OF DOORS PROVIDED BY THE CONTRACTOR W/ ALL REQ'D

HARDWARE & LOCKING DEVICES TO SECURE THE BUILDING

ENVELOPE FOR WEATHER TIGHTNESS AND SECURITY PURPOSES

AND PROVIDE PROPER ACCESS FOR THE CONTRACTOR TO THE

PROJECT AREA (MORTISE STOREROOM LOCKSET AND CLOSER,

ETC...). CONTRACTOR TO PROVIDE TEMPORARY ACCESS STAIRS

AS REQ'D TO PROPERLY ACCESS THE TEMPORARY DOORS AND

MEET ALL OF THE CODE REQUIREMENTS."

CONTRACTOR TO INSTALL NEW (1HR) RATED SHAFTWALL UP TO

DECK ABOVE ON EXISTING PARTITION FOR CONST. SEPARATION

PRIOR TO OTHER CONSTRUCTION.

AutoCAD SHX Text

CHEMO ROOM

AutoCAD SHX Text

ANTE ROOM

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

CLEAN PREP.

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

HAC

AutoCAD SHX Text

MOP SINK

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text

AutoCAD SHX Text Revisions

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Date

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VAMC, WEST HAVEN, CT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Approved: Project Manager

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Service Chief

AutoCAD SHX Text Project Title

AutoCAD SHX Text Location

AutoCAD SHX Text Building Number

AutoCAD SHX Text

VAMC, WEST HAVEN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Project No.

AutoCAD SHX Text Date

AutoCAD SHX Text Drawn

AutoCAD SHX Text Checked

AutoCAD SHX Text

VA

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text Department of

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text A

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-11-19

AutoCAD SHX Text 689-17-002

AutoCAD SHX Text

VA

AutoCAD SHX Text

WEST HAVEN, CT

AutoCAD SHX Text

INPATIENT PHARMACY IV

AutoCAD SHX Text

CONNECTICUT

AutoCAD SHX Text

HEALTHCARE

AutoCAD SHX Text

SYSTEM

AutoCAD SHX Text

VA

AutoCAD SHX Text

STAMP:

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

AutoCAD SHX Text

CORRECTIONS

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

CT PROFESSIONAL ENGINEER NO. 25337

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

AREA OF WORK FIRST FLOOR BLDG 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTE: SEE PHASING PLANS FOR EXITING/ACCESS DURING CONSTRUCTION AND TEMPORARY BARRIERS. SEE PHASING/ICRA PLANS FOR ADDITIONAL REQUIREMENTS.

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLITION PLAN - GROUND FLOOR

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLITION CEILING PLAN - GROUND FLOOR

AutoCAD SHX Text NOTE: 1. EXISTING FLOORING - SEAMLESS TYPE SHEETGOODS. EXISTING FLOORING - SEAMLESS TYPE SHEETGOODS. 2. EXISTING WALLS - GYPSUM BOARD AND STUDS. EXISTING WALLS - GYPSUM BOARD AND STUDS. 3. DEMOLITION AND ALL "LOUD" CONSTRUCTION WORK TO DEMOLITION AND ALL "LOUD" CONSTRUCTION WORK TO BE COMPLETED DURING OFF HOURS (NIGHT SHIFT).

NOTE: 1. EXISTING CEILING - PLASTIC CEILING TILES AND GRID.EXISTING CEILING - PLASTIC CEILING TILES AND GRID.

EXIST ELECTRICAL PANELS

4'-0"

CLEAR

3'- 9"

'-3

LAMINAR

FLOW HOOD

LAMINAR

FLOW HOOD

SHELVING

HW SINK

STERILE SIDE

DE

MA

RC

AT

IO

N

LIN

E

'-6

18'-11 1/2"

33'-7" 20'-2"

'-3

4'-

2 1 /2"

'-2

1/ 2"

ENTRY

6'-6"

EXISTING ENTRY

TO PHARMACY

PR

IN

TE

R

REF

MOBILE

CART

EW

BSC

3'- 6"

MI

N

MOBILE

CART

6' SHELVING

WORK STATION

8'-0"

REF

REFBSC

MOBILE

CART

MOBILE

CART

MOBILE

CART

DOFFING ZONE

FREEZER

BELOW

MOBILE

CART

4'-0"

BE

NC

H

6' SHELVING6' SHELVING6' SHELVING

8 1/2"

4'-0"

TR

AS

H

BI

N

TR

AS

H

BI

N

TR

AS

H

BI

N 4' LONG

SHELVING

BENCH

MOBILE

CART

MOBILE

CART

MOBILE

CART

TR

AS

H

BI

N

TR

AS

H

BI

N

18'-5 1/2"

DIRTY SIDE

COMP. ST.

COMP. ST.

MOBILE

WORK

COUNTER

MOBILE

CART

MOBILE

CART

MOBILE

CART

MOBILE

CART

MOBILE

CART

MOBILE

CART

3'- 5"

SHELVING

4'- 8 1

/2"

3'- 2"

3'-2"

2'-

TRASH

BIN

3'-3 1/2"

6'

SH

EL

VI

NG

6' SHELVING

2'- 7"

6'

SH

EL

VI

NG

MOBILE

CART

MOBILE

CART

MOBILE

CART

4'-1"

5'

SH

EL

VI

NG

MOBILE

WORK

COUNTER

2'- 6"

3'- 9"

5'-0"

REF

REF

SPLASH GUARD

1'- 9 1

/2"

8'-3"

3'- 2"

4'-0"

4'- 1 1

/2"

FEC

PASS-THRU

SEE NOTE #3

LIGHT BOX

LOCATION

EXISTING WINDOW

TO BE TINTED

EXISTING WINDOW

TO BE TINTED

EXISTING WINDOW

TO BE TINTED

EXISTING WINDOW

TO BE TINTED

LIGHT BOX

LOCATION

SECURITY

INTELLI-KEY PAD

LOCATION

FIRE/SMOKE RATING

(SEE 3-AS-500 FOR

PARTITION LEGEND)

NOMINAL SIZE

SPECIFICATION

CATEGORY

SEQUENCE NUMBER

DOOR NUMBER

DOOR SIZE (SEE

3-AS-600 FOR DOOR

SIZE LEGEND)

VIEW NUMBER

SHEET NUMBER

VIEW

NUMBER

SHEET

NUMBER

VIEW

NUMBER

SHEET

NUMBER

x-x-xx

3-AS-000

3-AS-00

NEW WALL AND DOOR

EXISTING WALL AND

DOOR TO REMAIN

NEW DOOR TAG

NEW PARTITION TAG

NEW WALL

SECTION TAG

NEW DETAIL

CALLOUT TAG

NEW INTERIOR

ELEVATION TAG

3-AS-000

000 EQUIPMENT TAG

STERILE SIDE

ENTRY

EXISTING ENTRY

TO PHARMACY

DIRTY SIDE

2'- 7 1

/2" 3'-

0 1 /2"

8'- 2"

2'-11"

9"

14'-8 1/2" 4 1 /2"

1'- 7"

1'- 0 1

/2"

12'-0" 2'-8 1/2" 4'-4" 8'-11" 8'-4 1/2" 3'-5" 3'-8"

8 1/2"

2'-3 1/2"

10 1/2"

1'- 6"

2'- 2"

3'- 6 1

/2"

4 1 /2"

2'- 4"

3'-

1/ 2"

7'- 5"

1'- 8"

1'-6"

1'-6" 13'-2 1/2" 4'-4" 9'-0"

4'-11 1/2" 9 1/2"

5'-3 1/2" 6'-8 1/2"

8'- 0"

8'-6"

5 1 /2"

1'-11"

3'- 0"

8'- 0"

2'-0"8'-0"

3'-6" CLEAR OPENING

3'-8" CLEAR OPENING

3'-6" CLEAR OPENING

3'-6" CLEAR

OPENING

6'-10 1/2"

17'-1"

'-3

1/ 2"

V

IF

'-3

33'-8" 1'-5 1/2" 20'-2 1/2"

13'-6" 3'-3 1/2"

2'- 5"

5'- 0"

2'- 7 1

/2" 8'-

8"

4'-0 1/2"18'-9"

3'-0"

9-4-3s

9-4-5

9-4-3s 9-4-4s

9-4-4s

9-4-4s

5'-

4'- 2 1

/2"

1'-4 1/2"

5'-2" 2'-5" 2'-10 1/2"

4 1 /2"

9-4-3sSIM

9-4-4s

TYP FEC

1'- 5 1

/2"

APPROX 24" HIGH CRAWL SPACE

NOTE: CUT/PATCH AND MODIFY AS

REQ'D FOR NEW PLUMBING WORK. DO

NOT DISTURB AREAS NEAR EXISTING

FOUNDATIONS/STRUCTURE.

STERILE SIDE

ENTRY

EXISTING ENTRY

TO PHARMACY

DIRTY SIDE

FEC

FEC

WALL MOUNTED FIRE

EXTINGUISHER

S

REFLECTED CEILING PLAN LEGEND

NEW 2'X2' CEILING GRID AND

CEILING TILES. REFER TO

ROOM FINISH SCHEDULE.

NEW ABUSE-RESISTANT, TYPE 'X'

GYPSUM BOARD CEILING

NEW 2'X2'

LIGHT FIXTURE

NEW 1'X4'

LIGHT FIXTURE

NEW SUPPLY

DIFFUSER

NEW RETURN

GRILLE

NEW FIRE SPRINKLER

NEW CEILING MOUNTED

OCCUPANCY SENSOR

NEW CEILING MOUNTED

DIRECTIONAL EXIT SIGN

NEW SMOKE DETECTOR.

SEE MEP DRAWINGS.

F i l e

N a m e

C

U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h

V

A

W e s t

H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t

A

S

D a t e

W e d

J a m e l s c h l e m o w i t z

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

PROPOSED DIMENSION PLAN

PROPOSED FLOOR PLAN

PROPOSED REF. CLG. PLAN

1-AS-100

1-AS-600

AutoCAD SHX Text 222A

AutoCAD SHX Text 41"

AutoCAD SHX Text

STERILE

AutoCAD SHX Text

STOR/PREP

AutoCAD SHX Text

AutoCAD SHX Text

242 SF

AutoCAD SHX Text

ANTE-ROOM

AutoCAD SHX Text

AutoCAD SHX Text

358 SF

AutoCAD SHX Text

HOUSE

AutoCAD SHX Text

KEEPING

AutoCAD SHX Text

AutoCAD SHX Text

18 SF

AutoCAD SHX Text

STERILE HD

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

AutoCAD SHX Text

313 SF

AutoCAD SHX Text

STERILE NON-HD

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

AutoCAD SHX Text

205 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

250 SF

AutoCAD SHX Text 223A

AutoCAD SHX Text 41"

AutoCAD SHX Text 224A

AutoCAD SHX Text 34"

AutoCAD SHX Text 226A

AutoCAD SHX Text 41"

AutoCAD SHX Text 225A

AutoCAD SHX Text 44"

AutoCAD SHX Text

ENTRY

AutoCAD SHX Text

AutoCAD SHX Text

66 SF

AutoCAD SHX Text 105A

AutoCAD SHX Text 36"

AutoCAD SHX Text N#

AutoCAD SHX Text X

AutoCAD SHX Text

FLOOR PLAN LEGEND

AutoCAD SHX Text

STERILE

AutoCAD SHX Text

STOR/PREP

AutoCAD SHX Text

AutoCAD SHX Text

242 SF

AutoCAD SHX Text

ANTE-ROOM

AutoCAD SHX Text

AutoCAD SHX Text

358 SF

AutoCAD SHX Text

HOUSE

AutoCAD SHX Text

KEEPING

AutoCAD SHX Text

AutoCAD SHX Text

18 SF

AutoCAD SHX Text

STERILE HD

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

AutoCAD SHX Text

313 SF

AutoCAD SHX Text

STERILE NON-HD

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

AutoCAD SHX Text

205 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

250 SF

AutoCAD SHX Text

ENTRY

AutoCAD SHX Text

AutoCAD SHX Text

66 SF

AutoCAD SHX Text

AS400

AutoCAD SHX Text 4-A

AutoCAD SHX Text 4-B

AutoCAD SHX Text 4-C

AutoCAD SHX Text 4-D

AutoCAD SHX Text

AS400

AutoCAD SHX Text 1-A

AutoCAD SHX Text 1-B

AutoCAD SHX Text 1-C

AutoCAD SHX Text 1-D

AutoCAD SHX Text

AS400

AutoCAD SHX Text 3-A

AutoCAD SHX Text 3-B

AutoCAD SHX Text

AS400

AutoCAD SHX Text 5-C

AutoCAD SHX Text 4-D

AutoCAD SHX Text 5-A

AutoCAD SHX Text 4-B

AutoCAD SHX Text

AS400

AutoCAD SHX Text

AutoCAD SHX Text

STERILE

AutoCAD SHX Text

STOR/PREP

AutoCAD SHX Text

AutoCAD SHX Text

242 SF

AutoCAD SHX Text

ANTE-ROOM

AutoCAD SHX Text

AutoCAD SHX Text

358 SF

AutoCAD SHX Text

HOUSE

AutoCAD SHX Text

KEEPING

AutoCAD SHX Text

AutoCAD SHX Text

18 SF

AutoCAD SHX Text

STERILE HD

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

AutoCAD SHX Text

313 SF

AutoCAD SHX Text

STERILE NON-HD

AutoCAD SHX Text

BUFFER ROOM

AutoCAD SHX Text

AutoCAD SHX Text

205 SF

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

250 SF

AutoCAD SHX Text

ENTRY

AutoCAD SHX Text

AutoCAD SHX Text

66 SF

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text

AutoCAD SHX Text Revisions

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Date

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VAMC, WEST HAVEN, CT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Approved: Project Manager

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Service Chief

AutoCAD SHX Text Project Title

AutoCAD SHX Text Location

AutoCAD SHX Text Building Number

AutoCAD SHX Text

VAMC, WEST HAVEN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Project No.

AutoCAD SHX Text Date

AutoCAD SHX Text Drawn

AutoCAD SHX Text Checked

AutoCAD SHX Text

VA

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text Department of

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text A

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-11-19

AutoCAD SHX Text 689-17-002

AutoCAD SHX Text

VA

AutoCAD SHX Text

WEST HAVEN, CT

AutoCAD SHX Text

INPATIENT PHARMACY IV

AutoCAD SHX Text

CONNECTICUT

AutoCAD SHX Text

HEALTHCARE

AutoCAD SHX Text

SYSTEM

AutoCAD SHX Text

VA

AutoCAD SHX Text

STAMP:

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

AutoCAD SHX Text

CORRECTIONS

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

CT PROFESSIONAL ENGINEER NO. 25337

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

AREA OF WORK FIRST FLOOR BLDG 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED FLOOR PLAN - GROUND FLOOR

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED DIMENSION PLAN - GROUND FLOOR

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

CRAWL SPACE

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED REFLECTED CEILING PLAN - GROUND FLOOR

AutoCAD SHX Text ALTERATION NOTES: 1. EXISTING WINDOWS TO BE TINTED.INSTALL EXISTING WINDOWS TO BE TINTED.INSTALL NEW SHADING FILM AT EXTERIOR SIDE. 2. LEVEL FLOOR AS REQ'D FOR NEW FLOOR LEVEL FLOOR AS REQ'D FOR NEW FLOOR FINISHES (TYPICAL). 3. CONTRACTOR TO RESET FRAME OF EXISTING CONTRACTOR TO RESET FRAME OF EXISTING FLOOR ACCESS DOOR AS REQUIRED TO MAKE DOOR FLUSH WITH SURROUNDING FLOOR. IN ADDITION, CONTRACTOR TO INSTALL NEW CEMENTITIOUS LEVELING COMPOUND TO CREATE FLUSH TRANSITION. 4. THE CONTRACTOR SHALL FULLY CAULK AND THE CONTRACTOR SHALL FULLY CAULK AND SEAL ALL JOINTS IN THE INTERIOR SIDE OF THE EXTERIOR WALLS AND AT ALL INTERIOR PARTITIONS OF THE WORK AREA, AROUND ALL RECEPTACLES, AND AROUND ALL MECHANICAL OPENINGS AND PENETRATIONS.

AutoCAD SHX Text

1. ALL NEW ACT CEILING SYSTEMS ARE TO BE ALL NEW ACT CEILING SYSTEMS ARE TO BE INSTALLED MEETING ALL SEISMIC REQUIREMENTS FOR ASCE 7-05 SEISMIC DESIGN CATREGORY "C", ASTM C635, ASTM 636 AND CISCA FOR SEISMIC ZONE 0-2, FRICTION CLIPS SHALL NOT BE USED, MINIMUM 12 GA. WIRE, 7/8" PERIMETER CLOSEURE ANGLE WIDTH AND ALL OTHER REQUIREMENTS.

CEILING NOTES:

AREA OF EXISTING ROOF WHERE

CONTRACTOR IS TO REMOVE EXISTING

CURB AND RTU. AFTER REMOVAL, INSTALL

NEW METAL DECK, NEW INSULATION

(TAPERED) AND ROOFING TO MATCH

EXISTING.

AFTER REMOVAL OF EXISTING CURB;

CONTRACTOR TO PROVIDE AND INSTALL

NEW INFILL ROOF DECK CONSTRUCTION

WITH GALVANIZED CORRUGATED ROOF

DECK (MATCH EXISTING) AND 10" DP

COLD FORMED FRAMING (18 GA) TO

MATCH EXISTING. AREA OF NEW ROOF

DECK TO THEN BE REROOFED

(INSULATION, EPDM, FLASHING) AS REQ'D

TO MATCH EXISTING.

NOTE:

TYPICALLY INDICATES A NEW EXHAUST

DUCT PENETRATION (17 TOTAL)

CONTRACTOR TO PROVIDE AND INSTALL

NEW (12" HIGH MIN) SQUARE METAL CURB

(AND P.T. WOOD NAILERS AND BLOCKING AS

REQ'D) AND FULLY FLASH TO THE EXISTING

ROOF MEMBRANE. COORDINATE WITH

MECHANICAL DRAWINGS. PROVIDE WITH

FULLY SEALED STAINLESS STEEL CAP

FLASHING/COUNTER FLASHING.

NOTE:

CONTRACTOR TO PROVIDE AND INSTALL

NEW (12" HIGH MIN) SQUARE METAL CURB

FOR MECHANICAL UNITS (AND P.T. WOOD

NAILERS AND BLOCKING AS REQ'D) AND

FULLY FLASH TO THE EXISTING ROOF

MEMBRANE. COORDINATE WITH

MECHANICAL DRAWINGS. PROVIDE WITH

FULLY SEALED STAINLESS STEEL CAP

FLASHING/COUNTER FLASHING.

NOTE:

SEE MECHANICAL DRAWINGS FOR EXTENT

OF NEW DUCTWORK. CONTRACTOR TO

PROVIDE SEPARATION/PROTECTION

MEMBRANE UNDER ALL NEW SUPPORTS.

(TYPICAL)

MODIFY EXISTING ROOF, COORDINATE AS REQ'D.

NTS PROVIDE AT ALL PENTRATIONS

PIPE RAIL & VTR PENETRATION FLASHING DETAIL

F i l e

N a m e

C

U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h

V

A

W e s t

H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t

A

S

D a t e

W e d

J a m e l s c h l e m o w i t z

ENGINEERING LLP

www.fellp.com

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986

FE PROJECT #: 18-077

Liscum

181 CHURCH STREET

POUGHKEEPSIE, NEW YORK 12601

PHONE 845-452-2268 FAX 845-452-3752

ARCHITECTURE

PLANNING INTERIORS

McCormack VanVoorhis LLP

100% SUBMISSION

PROPOSED ROOF PLAN

1-AS-101

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

RTU - 2

AutoCAD SHX Text

RTU - 1

AutoCAD SHX Text

RTU - 4

AutoCAD SHX Text

RTU - 3

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text NOTE: PIPES TO BE ANCHORED TO BOTTOM OF ROOF DECK OR CONCRETE PLANKING TO ASSURE STABILITY

AutoCAD SHX Text

SPLICING CEMENT

AutoCAD SHX Text

PREMOLDED PIPE SEAL 8" HIGH MIN

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

WATER CUT-OFF MASTIC

AutoCAD SHX Text

S.S. CLAMP RING

AutoCAD SHX Text

RIGID INSULATION

AutoCAD SHX Text

MEMBRANE

AutoCAD SHX Text

LAP SEALANT

AutoCAD SHX Text

LAP SEALANT

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

INSEAM SEALANT( LOCATE 1/2" FROM INSIDE EDGE OF PIPE SEAL FLANGE)

AutoCAD SHX Text NOTE: PRE-MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE REGARDLESS OF PIPE DIAMETER

AutoCAD SHX Text

METAL DECK. VERIFY IN FIELD

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text

AutoCAD SHX Text Revisions

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Date

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VAMC, WEST HAVEN, CT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Approved: Project Manager

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Service Chief

AutoCAD SHX Text Project Title

AutoCAD SHX Text Location

AutoCAD SHX Text Building Number

AutoCAD SHX Text

VAMC, WEST HAVEN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Project No.

AutoCAD SHX Text Date

AutoCAD SHX Text Drawn

AutoCAD SHX Text Checked

AutoCAD SHX Text

VA

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text Department of

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text A

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-11-19

AutoCAD SHX Text 689-17-002

AutoCAD SHX Text

VA

AutoCAD SHX Text

WEST HAVEN, CT

AutoCAD SHX Text

INPATIENT PHARMACY IV

AutoCAD SHX Text

CONNECTICUT

AutoCAD SHX Text

HEALTHCARE

AutoCAD SHX Text

SYSTEM

AutoCAD SHX Text

VA

AutoCAD SHX Text

STAMP:

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

AutoCAD SHX Text

CORRECTIONS

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

CT PROFESSIONAL ENGINEER NO. 25337

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

AREA OF WORK FIRST FLOOR BLDG 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED ROOF PLAN

ROOF PLAN LEGEND

STERILE SIDE

ENTRY

EXISTING ENTRY

TO PHARMACY

DIRTY SIDE

L2280

R6060

M2080

L2280

R6060

R6060

R6060

R6060

M2080 M2080 M2080

M2080

M2080

M2080

M2

M2

F2

F2

F2

F2

F2

F2

F0

F0

F0535 K1910

M2

K1910

F0535

F0535 F0535

F0535 F0535

F0535

F0

F0

F0

F0535

P1965 A5075F0535

U1200

FEC

F0535F0535F0535

F0

F0

A

D

B B B

B

B B

C

A A A

B

LB1

LB1

PRINTER

PRINTER

P2451

A1014U3500EXU3500EX

UCFRZ

A1014

UPE01A

UPE01A

A1014

A5145

P3000

CA040

A1014

A1014

UPE01

FURNITURE AND

EQUIPMENT BY VA

NEW WALL AND DOOR

EXISTING WALL AND

DOOR TO REMAIN

000 EQUIPMENT TAGPHARMACY EQUIPMENT SCHEDULE

EQUIPMENT LIST

JSN NAME AI QTY DESCRIPTION

A1014 WALL MOUNTED PHONE V/V 5 TELEPHONE, WALL MOUNTED, I LINE WITH SPEAKER

A5075 DISPENSER SOAP,

DISPOSABLE V/V 2

DISPOSABLE SOAP DISPENSER, ONE-HANDED

DISPENSING OPERATION. DESIGNED TO ACCOMMODATE

DISPOSABLE SOAP CARTRIDGE AND VALVE

A5077 DISPENSER, HAND

SANITIZER, HANDS-FREE V/V 6

A TOUCH FREE WALL-MOUNTED HAND SANITIZER

DISPENSE. DOES NOT INCLUDE SANITIZING LIQUID.

BATTERY OPERATED

A5100 SHOE COVER

DISPENSER, SMALL V/V 2 A SHOE COVER DISPENSER, THAT HOLDS UP TO 55 PAIRS

OF SHOE COVERS

A5145

HOOK, GARMENT,

DOUBLE, SS, SURFACE

MOUNTED

C/C 2

SURFACE MOUNTED, SATIN FINISH STAINLESS STEEL,

DOUBLE GARMENT HOOK, EQUIPPED WITH A CONCEALED

MOUNTING BRACKET THAT IS SECURED TO A CONCEALED

WALL PLATE

CA040

CABINET, OPEN, W/H, 2

SHELF, SLOPING

TOP38"X24"X13"

C/C 1

WALL OPEN OPEN FRONT CABINET, STAINLESS STEEL

CONSTRUCTION WITH SLOPED TOP AND TWO

ADJUSTABLE SHELVES

F0535 CART, UTILITY V/V 12 STAINLESS STEEL UTILITY CART, 40" HIGH X 36" WIDE X

24" DEEP WITH 4 HEAVY DUTY CASTER WHEELS

F2010 BASKET WASTE PAPER,

STEP ON V/V # STEP-ON WASTEPAPER BASKET WITH INNER LINER AND

FOOT PETAL ACTIVATED FLIP TOP, 36" X 15"

F2245

CAMERA, VIDEO

SURVEILLANCE, HD, IP

POWERED

V/V #

A HIGH DEFINITION, FULL FUNCTIONAL VIDEO

SURVEILLANCE CAMERA, CAPABLE OF FULL 1080P

RESOLUTION AT 30 FRAMES PER SECOND WHILE

OPTIMIZING NETWORK USAGE WITH H.264, MEPG-4 AND

JPEG COMPRESSION FORMATS.

M2080A

SHELVING STORAGE,

SOLID, STAINLESS STEEL

WITH ADJUSTABLE

SHELVES AND CASTERS

V/V 1 METRO…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.