36C24119R0074-0003001.pdf
PDF 5 MB Posted
- Solicitation number
- 36C24119R0074
About this file
36C24119R0074 0003 S06 Drawings In-Patient Pharmacy IV 1 OF 3.pdf
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8.5
16A
35A
WEST SPRING STREET
36A
SHELTER
15A
SERVICE ROAD
SERVICE ROAD
2A
PET
LC1A
8.5
16A
35A
36A
15A
6A
2A
TS
TITLE SHEET WITH
INDEX TO DRAWINGS
SITE MAP
F i l e
N a m e
F
W e s t
H a v e n
P h a r m a c y
I V
T
S d w g
L a y o u t
T
S
D a t e
F r i
J u l
M
N a m e
F
E
C
A D
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% FOR BID
No. 25337
Q U I T R A N S T U L I T
B U S T IN E T
J O
H
D
F
E
L
L
E
N
Z E R E
N G
I
N
E
E
R
I N G
L L P
S
T
A
T
O
CO
N
E
C
T
I
C
U
T
P
R
O
F
E
S
S
I
O
A L
G
I
N
E
E
R
L
I
C
E N
S
FEC
A
D
B B B
B
B B
C
A A A
B
LB1
LB1
PRINTER
PRINTER
TUBE SYSTEMCO
UN
TE
R
EXAM
G206
EXAM
G205
VESTIBULE
G204
HIGH RISK
PHASE I
CONSTRUCTION
PHASE II
CONSTRUCTION
1-GI-001
ICRA PLAN & NOTES
NOTES:
PATIENT RISK GROUP FOR "TYPE D" CONSTRUCTION
LOW RISK GROUP
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP Class IV
Class III / IV
Class IV Class IV
UL U465 (1 HOUR RATED)
FIRECODE 'X' GYPSUM BD PANELS
APPLIED VERTICALLY OR
HORIZONTALLY. HORIZONTAL JOINTS
NEED NOT BE STAGGERED. FACE
LAYER JOINTS TO BE FINISHED. FIRE
CAULK ALL PENETRATIONS.
CONSTRUCTION PARTITION WALL DETAIL
N.T.S.2
GROUND ICRA FLOOR PLAN1
F i l e
N a m e
F
W e s t
H a v a r m a c y
I V
G
I d a y o u t
G
I
D a t e
F r i
J u l a m e
F
E
C
A D
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% FOR BID
No. 25337
Q U I T R A N S T U L I T
B U S T IN E T
J O
L
L
E
N
Z E R E
N G
I
N
E
E
R
I N G
L L P
S
T
A
N
E
C
T
I
C
U
T
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
L
I
C
E N
S
E
PHASING NOTES:
1-GI-002
PARTIAL MECHANICAL
SITE PLAN
PARTIAL MECHANICAL SITE PLAN1
F i l e
N a m e
F
W e s t
H a v a r m a c y
I V
G
I d a y o u t
G
I
D a t e
F r i
J u l a m e
F
E
C
A D
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% FOR BID
No. 25337
Q U I T R A N S T U L I T
B U S T IN E T
J O
L
L
E
N
Z E R E
N G
I
N
E
E
R
I N G
L L P
S
T
A
N
E
C
T
I
C
U
T
P
R
O
F
E
S
S
I
O
G
I
N
E
E
R
L
I
C
E N
S
E
D
TYPICAL CHAIN LINK FENCE AND GATE2
KEYED NOTES:
SECTION VIEW
TYPICAL GRAVEL SURFACACE3
9-4-2b
W#
3-AS-000
3-AS-000
3-AS-000
3-AS-000
3-AS-000
FIRE/SMOKE RATING (SEE
3-AS-500 FOR PARTITION
LEGEND)
NOMINAL SIZE
SPECIFICATION CATEGORY
SEQUENCE NUMBER
DOOR NUMBER
DOOR SIZE (SEE 3-AS-600
FOR DOOR SIZE LEGEND)
VIEW NUMBER
SHEET NUMBER
VIEW NUMBER
SHEET NUMBER
VIEW
NUMBER
SHEET
NUMBER
VIEW
NUMBER
SHEET
NUMBER
VIEW NUMBER
SHEET NUMBER
F i l e
N a m e
C
U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h
V
A
W e s t
H a v
C o m p o u n d i n g
I V
S u i t e F l o o r P l a n d a y o u t
A
S
D a t e
W e d
J a a m e l s c h l e m o w i t z
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% SUBMISSION
ARCHITECTURAL: SYMBOLS,
ABBREVIATIONS AND NOTES
1-AS-001
AutoCAD SHX Text GENERAL NOTES: 1. IN THE EVENT OF INCONSISTENCIES WITHIN OR BETWEEN PARTS OF THE CONTRACT IN THE EVENT OF INCONSISTENCIES WITHIN OR BETWEEN PARTS OF THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE STANDARDS, CODES AND ORDINANCES, THE CONTRACTOR SHALL: (1) PROVIDE THE BETTER QUALITY OR GREATER QUANTITY OF WORK OR (2) COMPLY WITH THE MORE STRINGENT REQUIREMENT; EITHER OR BOTH IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. 2. VERIFY ALL DIMENSIONS IN FIELD FOR FIT OF UNITS SPECIFIED. MODIFY VERIFY ALL DIMENSIONS IN FIELD FOR FIT OF UNITS SPECIFIED. MODIFY DIMENSIONS ON SHOP DRAWING AS REQUIRED, PRIOR TO SUBMITTAL OR RELEASE FOR PURCHASE OR FABRICATION. 3. ALL ARCHITECTURAL CASEWORK & WOODWORK IS TO BE INSTALLED ON TOP OF ALL ARCHITECTURAL CASEWORK & WOODWORK IS TO BE INSTALLED ON TOP OF NEW FLOOR FINISHES. (CARPET, SHEET VINYL., ETC.) 4. THE DESIGN OF THE PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL THE DESIGN OF THE PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 5. CONTRACTORS SHALL VERIFY & ASSUME RESPONSIBILITY FOR VERIFYING ALL CONTRACTORS SHALL VERIFY & ASSUME RESPONSIBILITY FOR VERIFYING ALL EXISTING OR AS-BUILT CONDITIONS AND INCLUDE INFORMATION IN SHOP DRAWINGS PRIOR TO SUBMITTAL TO A & E. 6. EACH CONTRACTOR TO BE RESPONSIBLE FOR APPLIED FINISHES FOR THEIR WORK. EACH CONTRACTOR TO BE RESPONSIBLE FOR APPLIED FINISHES FOR THEIR WORK. 7. IN AREA OF WORK EACH CONTRACTOR TO BE RESPONSIBLE FOR ALL ADJACENT IN AREA OF WORK EACH CONTRACTOR TO BE RESPONSIBLE FOR ALL ADJACENT FINISHED WORK OF OTHER TRADES. EACH CONTRACTOR IS TO PROTECT HIS OWN WORK. 8. ALL CONTRACTORS ARE TO COORDINATE THEIR WORK IN ACCORDANCE WITH ALL CONTRACTORS ARE TO COORDINATE THEIR WORK IN ACCORDANCE WITH DRAWINGS. 9. ALL PENETRATIONS THROUGH RATED WALLS & CORRIDOR WALLS ARE TO BE ALL PENETRATIONS THROUGH RATED WALLS & CORRIDOR WALLS ARE TO BE FIRE-STOPPED BY TRADE MAKING PENETRATION, WITH APPROVED MATERIALS PER DRAWINGS AND SPECIFICATIONS. 10. ALL DIMENSIONS SHOWN ON DRAWINGS ARE SUBJECT TO VERIFICATION OF ACTUAL ALL DIMENSIONS SHOWN ON DRAWINGS ARE SUBJECT TO VERIFICATION OF ACTUAL DIMENSIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD TO INSURE PROPER AND ACCURATE FIT OF MATERIALS AND ITEMS TO BE INSTALLED. 11. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER AND THE INFORMATION FURNISHED BY THE OWNER, AND SHALL AT ONCE REPORT TO THE ARCHITECT ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED. THE CONTRACTOR SHALL NOT BE LIABLE TO THE OWNER, OR ARCHITECT FOR DAMAGE RESULTING FROM ERRORS, INCONSISTENCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS UNLESS THE CONTRACTOR RECOGNIZED SUCH ERROR, INCONSISTENCY OR OMISSION AND KNOWINGLY FAILED TO REPORT IT TO THE ARCHITECT. IF THE CONTRACTOR PERFORMS ANY CONSTRUCTION ACTIVITY KNOWING IT INVOLVES A RECOGNIZED ERROR, INCONSISTENCY OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT SUCH NOTICE TO THE ARCHITECT, THE CONTRACTOR SHALL ASSUME APPROPRIATE RESPONSIBILITY FOR SUCH PERFORMANCE AND SHALL BEAR AN APPROPRIATE AMOUNT OF THE ATTRIBUTABLE COSTS FOR CORRECTION. 12. WHENEVER THE DRAWINGS SHOW EXISTING CONSTRUCTION, REQUIRED AS PART OF WHENEVER THE DRAWINGS SHOW EXISTING CONSTRUCTION, REQUIRED AS PART OF THE WORK OR NOT, IT IS UNDERSTOOD THAT IT IS SHOWN AS A MATTER OF INFORMATION TO BE SUBSTANTIALLY CORRECT. THE OWNER ASSUMES NO RESPONSIBILITY THEREFORE. THE CONTRACTOR SHALL MAKE ITSELF TOTALLY FAMILIAR WITH ALL EXISTING CONDITIONS AFFECTING THE NATURE AND MANNER OF CONDUCTING THEIR WORK. ANY ERRORS DUE TO THE CONTRACTOR'S FAILURE TO VERIFY ALL GRADES, ELEVATIONS, LOCATIONS, OR DIMENSIONS SHALL BE PROMPTLY RECTIFIED BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO THE OWNER. 13. WHERE EQUIPMENT LINES OR PIPING AND/OR CONDUIT ARE SHOWN WHERE EQUIPMENT LINES OR PIPING AND/OR CONDUIT ARE SHOWN DIAGRAMMATICALLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND ORDERLY ARRANGEMENT OF THE VARIOUS LINES OF PIPING AND CONDUIT INCLUDED IN THE WORK OF HIS CONTRACT. HE SHALL COORDINATE THE WORK OF SEVERAL CONTRACTORS AND PREVENT ALL INTERFERENCE'S BETWEEN EQUIPMENT, LINES OF PIPING, ARCHITECTURAL FEATURES, AND AVOID ANY UNSIGHTLY ARRANGEMENTS IN THE EXPOSED AREAS. 14. ALL WORK SHALL BE EXECUTED IN A THOROUGH, SUBSTANTIAL, WORKMANLIKE ALL WORK SHALL BE EXECUTED IN A THOROUGH, SUBSTANTIAL, WORKMANLIKE MANNER, IN COMPLETE ACCORDANCE WITH THE MANUFACTURER'S MOST RECENT RECOMMENDATIONS UNLESS OTHERWISE SPECIFIED OR PERMITTED BY THE ARCHITECT.
AutoCAD SHX Text HEALTH & SAFETY GENERAL NOTES: HEALTH & SAFETY GENERAL NOTES: 1. ALL EXISTING EXIT DOORS ARE REQUIRED TO BE KEPT CLEAR AT ALL ALL EXISTING EXIT DOORS ARE REQUIRED TO BE KEPT CLEAR AT ALL TIMES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF CHEMICAL FUMES, GASES, AND OTHER CONTAMINATES PRODUCED BY WELDING, GASOLINE OR DIESEL ENGINES, ROOFING, PAVING, PAINTING, ETC., TO ENSURE THEY DO NOT ENTER OCCUPIED PORTIONS OF THE BUILDING OR AIR INTAKES. 3. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ACTIVITIES THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ACTIVITIES AND MATERIALS WHICH RESULT IN "OFF-GASSING" OF VOLATILE ORGANIC COMPOUNDS SUCH AS GLUES, PAINTS, FURNITURE, CARPETING, WALL COVERING, DRAPERY, ETC., ARE SCHEDULED, CURED OR VENTILATED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS BEFORE A SPACE CAN BE OCCUPIED. DOORS & FRAMES 1. CENTER LINE OF ALL PANIC DEVICES. PUSH BARS SHALL BE 38" (3'-2") CENTER LINE OF ALL PANIC DEVICES. PUSH BARS SHALL BE 38" (3'-2") ABOVE FINISHED FLOOR (MAX. VERIFY WITH VA) 2. CLEAN AND CAULK THE FULL PERIMETER OF ALL GLASS, FRAMES, AND CLEAN AND CAULK THE FULL PERIMETER OF ALL GLASS, FRAMES, AND PANEL EDGES OF NEW FRAMES AND LITES AS PER SPECIFICATIONS. 3. ALL NEW FRAMES IN GYPSUM BOARD PARTITIONS TO HAVE THREE (3) ALL NEW FRAMES IN GYPSUM BOARD PARTITIONS TO HAVE THREE (3) ANCHORS PER JAMB MINIMUM INTO STUD AND FRAME. 4. ALL DOOR FRAMES SHALL BE PROVIDED WITH SILENCERS. ALL DOOR FRAMES SHALL BE PROVIDED WITH SILENCERS. 5. EXTERIOR METAL DOORS AND FRAMES ARE TO BE INSULATED. EXTERIOR METAL DOORS AND FRAMES ARE TO BE INSULATED. PLUMBING 1. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL NEW PLUMBING PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL NEW PLUMBING FIXTURES AS INDICATED (SEE PLANS, SPEC, AND SCHEDULE) WITH ALL REQUIRED PIPING, TRAPS, VENTING, CLEANOUTS, ETC., AS SHOWN OR AS REQUIRED PER CODE. 2. ALL EXPOSED PIPING BELOW NEW SINKS/LAVATORIES ARE TO BE ALL EXPOSED PIPING BELOW NEW SINKS/LAVATORIES ARE TO BE INSULATED/PROTECTED TO MEET ALL ADA REQUIREMENTS. 3. PLUMBING CONTRACTOR TO COORDINATE HIS WORK IN SPECIAL ROOMS PLUMBING CONTRACTOR TO COORDINATE HIS WORK IN SPECIAL ROOMS WITH CASEWORK ROUGH-IN REQUIREMENTS OF THAT TRADE AND TO COORDINATE HIS WORK IN STARBUCKS AREA WITH ROUGH-IN REQUIREMENTS. ARCHITECTURAL CASEWORK & EQUIPMENT 1. GENERAL CONTRACTOR IS TO PROVIDE ALL ROUGH-IN INFORMATION ON GENERAL CONTRACTOR IS TO PROVIDE ALL ROUGH-IN INFORMATION ON SHOPS (LOCATION & SIZE) SO AS NOT TO DELAY THE WORK OF OTHER TRADES. THE WORK OF OTHER TRADES IS BUILT INTO THE STRUCTURE, CASEWORK SHOPS MUST BE SUBMITTED AND APPROVED PRIOR TO ERECTION OF STRUCTURE. 2. ALL CABINET DOORS AND DRAWERS TO HAVE LOCKS EXCEPT SINK ALL CABINET DOORS AND DRAWERS TO HAVE LOCKS EXCEPT SINK CABINETS. CABINET LOCKS IN ALL ROOMS TO BE KEYED ALIKE IN EACH ROOM AND DIFFERENTLY FROM OTHER ROOMS. 3. GENERAL CONTRACTOR SHALL INSTALL ALL ARCHITECTURAL CASEWORK GENERAL CONTRACTOR SHALL INSTALL ALL ARCHITECTURAL CASEWORK FOR ALL ROOMS SHOWN ON PLANS OR CALLED FOR IN SCHEDULES. INSTALL ALL TOPS, BACK SPLASHES, FILLERS, BLOCKING, ETC. 4. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PIPE CHASES OR GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PIPE CHASES OR OTHER OBSTRUCTIONS IN FIELD FOR PROPER INSTALLATION OF CABINETWORK AND ALTER WORK AS NECESSARY FOR PROPER FIT. 5. GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL GROMMETS AS GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL GROMMETS AS REQUIRED TO ALLOW ACCESS TO ALL POWER, DATA AND COMMUNICATION RECEPTACLES. 6. PROVIDE AND INSTALL NEW CONCEALED, FIRE RETARDANT BLOCKING AT PROVIDE AND INSTALL NEW CONCEALED, FIRE RETARDANT BLOCKING AT ALL NEW ACCESSORIES/CASEWORK AS REQUIRED.
AutoCAD SHX Text
NEW WALL AND DOOR
AutoCAD SHX Text
EXISTING WALL AND DOOR TO REMAIN
AutoCAD SHX Text N#
AutoCAD SHX Text X
AutoCAD SHX Text
NEW WINDOW/ STOREFRONT TAG
AutoCAD SHX Text
NEW DOOR TAG
AutoCAD SHX Text
NEW PARTITION TAG
AutoCAD SHX Text
NEW EXTERIOR ELEVATION TAG
AutoCAD SHX Text
NEW WALL SECTION TAG
AutoCAD SHX Text
NEW BUILDING SECTION TAG
AutoCAD SHX Text
NEW INTERIOR ELEVATION TAG
AutoCAD SHX Text
NEW DETAIL CALLOUT TAG
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VAMC, WEST HAVEN, CT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Approved: Project Manager
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Service Chief
AutoCAD SHX Text Project Title
AutoCAD SHX Text Location
AutoCAD SHX Text Building Number
AutoCAD SHX Text
VAMC, WEST HAVEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Project No.
AutoCAD SHX Text Date
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
VA
AutoCAD SHX Text Veterans Affairs
AutoCAD SHX Text Department of
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text A
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-11-19
AutoCAD SHX Text 689-17-002
AutoCAD SHX Text
VA
AutoCAD SHX Text
WEST HAVEN, CT
AutoCAD SHX Text
INPATIENT PHARMACY IV
AutoCAD SHX Text
CONNECTICUT
AutoCAD SHX Text
HEALTHCARE
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
VA
AutoCAD SHX Text
STAMP:
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
AutoCAD SHX Text
CORRECTIONS
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
CT PROFESSIONAL ENGINEER NO. 25337
AutoCAD SHX Text
JOHN D. FELLENZER, P.E.
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AREA OF WORK FIRST FLOOR BLDG 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
* BRICK
AutoCAD SHX Text
* EXISTING TO BE REMOVED
AutoCAD SHX Text
* NEW STUD WALLS
AutoCAD SHX Text
* EXISTING TO REMAIN
AutoCAD SHX Text
* EARTH
AutoCAD SHX Text
* POUROUS FILL
AutoCAD SHX Text
* METAL / STEEL
AutoCAD SHX Text
* INSULATION
AutoCAD SHX Text
* WOOD
AutoCAD SHX Text
* SPLIT FACE CONCRETE BLOCK
AutoCAD SHX Text
* CONCRETE
AutoCAD SHX Text
MATERIALS
AutoCAD SHX Text
PARTITIONS (PLAN)
AutoCAD SHX Text 1.) THE CONTRACTOR IS TO VISIT THE SITE AND THOROUGHLY ACQUAINT HIMSELF WITH ALL EXIST. CONDITIONS TO CHECK AND VERIFY ALL CONDITIONS, DIMENSIONS, ETC. AND REPORT TO THE ARCHITECT ANY ERRORS, OMISSIONS OR VARIATION FROM INTENT OF THE PLANS PRIOR TO THE START OF WORK. 2.) NO DRAWINGS ARE TO BE SCALED: USE DIMENSIONS ONLY OR VERIFY ALL CONDITIONS IN FIELD. 3.) THOSE ITEMS NOT NOTED, BUT IMPLIED AS NECESSARY FOR THE PERFORMANCE OF THE CONTRACT ARE CONSIDERED PART OF THE WORK. 4.) ALL MATERIAL AND WORKMANSHIP IS TO BE GUARANTEED BY THE CONTRACTOR TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR, THE CONTRACTOR AGREES TO CORRECT WITHOUT CHARGE SUCH CONDITIONS AS MAY OCCUR DURING THE GUARANTEE PERIOD. 5.) ALL WORK IS TO BE EXECUTED BY MECHANICS SKILLED IN THEIR TRADES. 6.) ALL CHANGES AND OR SUBSTITUTIONS ARE TO BE APPROVED IN WRITING BEFORE BEING INCORPORATED INTO THE WORK. 7.) ALL TRADES TO COOPERATE WITH EACH OTHER TO FACILITATE THE PROGRESS OF THE ENTIRE JOB. 8.) CONTRACTOR IS TO PROTECT THE PUBLIC AND PREMISES DURING THE PERIOD OF CONSTRUCTION WITH ADEQUATE SHORING, BRACING, FENCING, LIGHTING, ETC. . 9.) CONTRACTOR IS TO REMOVE ALL RUBBISH FROM THE SITE ON A DAILY BASIS (AS PER ICRA AND VA GUIDELINES) RESULTING FROM HIS WORK DURING THE PROGRESS OF CONSTRUCTION AND SHALL LEAVE THE PREMISES IN A CONDITION SATISFACTORY TO THE OWNER PRIOR TO THE FINAL INSPECTION. 10.) ALL MATERIALS, ASSEMBLIES, CONSTRUCTION AND EQUIPMENT SHALL CONFORM TO THE REGULATIONS OF THE INTERNATIONAL BUILDING CODE AND SHALL CONFORM TO GENERALLY ACCEPTED STANDARDS.
AutoCAD SHX Text A.B. ANCHOR BOLT ANCHOR BOLT AC ACOUSTICAL ACOUSTICAL ACT ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE ADJ ADJACENT ADJACENT AFF ABOVE FINISH FLOOR ABOVE FINISH FLOOR ALUM ALUMINUM ALUMINUM ANOD ANODIZED ANODIZED A.P. ACCESS PANEL ACCESS PANEL ARCH ARCHITECT ARCHITECT ASPH ASPHALT ASPHALT APPROX APPROXIMATE APPROXIMATE @ AT AT BLDG BUILDING BUILDING BLK BLOCK BLOCK BOT BOTTOM BOTTOM B/O BOTTOM OF BOTTOM OF BRK BRICK BRICK CBL CONCRETE BLOCK CONCRETE BLOCK CLG CEILING CEILING C.T. CERAMIC TILE CERAMIC TILE CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT CONC CONCRETE CONCRETE CONT CONTINUOUS CONTINUOUS C.J. CONTROL JOINT CONTROL JOINT CENTERLINE CB CATCH BASIN CATCH BASIN DIA./ DIAMETER DN DOWN DOWN DR DRAIN DRAIN DWG DRAWING DRAWING ELEC ELECTRIC ELECTRIC EL/ELEV ELEVATION ELEVATION EQUIP EQUIPMENT EQUIPMENT EXIST EXISTING EXISTING EXP JT EXPANSION JOINT EXPANSION JOINT EXT EXTERIOREXTERIOR
AutoCAD SHX Text FIN FINISH FINISH FIN FL FINISHED FLOOR FINISHED FLOOR FD FLOOR DRAIN FLOOR DRAIN FGL FIBERGLASS FIBERGLASS FL FLOOR FLOOR GA GAGE/GAUGE GAGE/GAUGE GALV GALVANIZED GALVANIZED GC GENERAL CONTRACTOR GENERAL CONTRACTOR GL GLASS GLASS GWB GYPSUM WALL BD GYPSUM WALL BD HC HUNG CEILING HUNG CEILING HDW HARDWARE HARDWARE HM HOLLOW METAL HOLLOW METAL HOR HORIZONTAL HORIZONTAL HP HIGH POINT HIGH POINT H+V HEATING AND VENTILATION HEATING AND VENTILATION INSUL INSULATION INSULATION JAN JANITOR JANITOR JT JOINT JOINT LAM LAMINATE LAMINATE MAS MASONRY MASONRY MATL MATERIAL MATERIAL MECH MECHANICAL MECHANICAL MIN MIN MIN M.O. MASONRY OPENING MASONRY OPENING MAX MAXIMUM MAXIMUM MTL METAL METAL N.I.C. NOT IN CONTRACT NOT IN CONTRACT NTS NOT TO SCALE NOT TO SCALE NO. NUMBER NUMBER OPNG OPENING OPENING O.C. ON CENTERON CENTER
AutoCAD SHX Text PARTN PARTITION PARTITION P+D PLUMBING AND DRAINAGE PLUMBING AND DRAINAGE POLY POLYURETHANE POLYURETHANE PROPERTY LINE PT PRESSURE TREATED PRESSURE TREATED PTD PAINTED PAINTED R RISER OR RADIUS RISER OR RADIUS RDL ROOF DRAIN LEADER ROOF DRAIN LEADER REINF REINFORCED REINFORCED REQD REQUIRED REQUIRED RM ROOM ROOM SC SOLID CORE SOLID CORE SECT SECTION SECTION SIM SIMILAR SIMILAR SPEC SPECIFICATION SPECIFICATION STL STEEL STEEL SAD SADDLE SADDLE STOR STORAGE STORAGE T TREAD OR TOP TREAD OR TOP TEL TELEPHONE TELEPHONE T&G TONGUE AND GROOVE TONGUE AND GROOVE THK THICK THICK T/O TOP OF TOP OF TW TOP OF WALL TOP OF WALL TYP TYPICAL TYPICAL VB VAPOR BARRIER VAPOR BARRIER VERT VERTICAL VERTICAL W WIDE WIDE WH WEEP HOLE WEEP HOLE WST WAINSCOT WAINSCOT WWF WELDED WIRE FABRIC WELDED WIRE FABRIC W/ WITH WITH WD WOODWOOD
AutoCAD SHX Text
ABBREVIATIONS (U.N.O.) (U.N.O.)
AutoCAD SHX Text
GENERAL SPECIFICATION NOTES
AutoCAD SHX Text
SYMBOLS LEGEND
AutoCAD SHX Text
GENERAL NOTES
20" HIGH CRAWL SPACE AREA, V.I.F.
FIRE/SMOKE RATING
(SEE 3-AS-500 FOR
PARTITION LEGEND)
NOMINAL SIZE
SPECIFICATION
CATEGORY
SEQUENCE NUMBER
DOOR NUMBER
DOOR SIZE (SEE
3-AS-600 FOR DOOR
SIZE LEGEND)
VIEW NUMBER
SHEET NUMBER
VIEW
NUMBER
SHEET
NUMBER
VIEW
NUMBER
SHEET
NUMBER
x-x-xx
3-AS-000
3-AS-00
NEW WALL AND DOOR
EXISTING WALL AND
DOOR TO REMAIN
NEW DOOR TAG
NEW PARTITION TAG
NEW WALL
SECTION TAG
NEW DETAIL
CALLOUT TAG
NEW INTERIOR
ELEVATION TAG
3-AS-000
000 EQUIPMENT TAG
F i l e
N a m e
C
U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h
V
A
W e s t
H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t
A
S E
D a t e
W e d
J a m e l s c h l e m o w i t z
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% SUBMISSION
EXISTING FLOOR PLAN
EXISTING CRAWL SPACE
AND ROOF PLAN
1-AS-E100
AutoCAD SHX Text
CHEMO ROOM
AutoCAD SHX Text
ANTE ROOM
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
CLEAN PREP.
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
HAC
AutoCAD SHX Text
MOP SINK
AutoCAD SHX Text N#
AutoCAD SHX Text X
AutoCAD SHX Text
FLOOR PLAN LEGEND
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VAMC, WEST HAVEN, CT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Approved: Project Manager
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Service Chief
AutoCAD SHX Text Project Title
AutoCAD SHX Text Location
AutoCAD SHX Text Building Number
AutoCAD SHX Text
VAMC, WEST HAVEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Project No.
AutoCAD SHX Text Date
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
VA
AutoCAD SHX Text Veterans Affairs
AutoCAD SHX Text Department of
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text A
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-11-19
AutoCAD SHX Text 689-17-002
AutoCAD SHX Text
VA
AutoCAD SHX Text
WEST HAVEN, CT
AutoCAD SHX Text
INPATIENT PHARMACY IV
AutoCAD SHX Text
CONNECTICUT
AutoCAD SHX Text
HEALTHCARE
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
VA
AutoCAD SHX Text
STAMP:
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
AutoCAD SHX Text
CORRECTIONS
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
CT PROFESSIONAL ENGINEER NO. 25337
AutoCAD SHX Text
JOHN D. FELLENZER, P.E.
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AREA OF WORK FIRST FLOOR BLDG 1
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING PLAN - CRAWL SPACE
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING FLOOR PLAN - GROUND FLOOR
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
ROOF PLAN - EXISTING
2 22
PHASE I
PARTITION TO
REMAIN DURING
PHASE II. PHASE II ENTRY.
PHASE I ENTRYREMOVE WINDOW, CUT & PATCH WALL FOR TEMPORARY
PHASE I ENTRY. WINDOW TO BE REINSTALLED AND WALL TO
BE RECONSTRUCTED AT END OF PHASE I. (SEE NOTE #16)
PHASE II
PARTITION
PHASE I
PARTITION
PHASE I
PARTITION
PHASE II
INTERIOR
WORK AREA
PHASE I
INTERIOR
WORK AREA19
PHASE II ENTRY.
PHASE II ENTRY: CUT &
PATCH EXTERIOR WALL
FOR TEMPORARY PHASE II
ENTRY (SIMILAR TO NOTE
#16, EXCEPT - SINGLE
3'-0"x 6'-8" HOLLOW METAL
DOOR & FRAME)
PHASE I
PARTITION TO
REMAIN DURING
PHASE II. PHASE II ENTRY.
PHASE I ENTRY
PHASE II
PARTITION
PHASE I
PARTITION
PHASE I
PARTITION
PHASE II
INTERIOR
WORK AREA
PHASE I
INTERIOR
WORK AREA
PHASE II ENTRY.
1. DRAWING SHOWS GENERAL EXTENT OF DEMOLITION AND
REMOVALS. THE CONTRACTOR SHALL MAKE ALL REMOVAL
AS REQUIRED TO PROPERLY INSTALL ALL NEW WORK. SEE
PHASING/ICRA.
2.DEMOLITION AND REMOVALS SHALL BE PERFORMED SO
THAT EXISTING FINISHES, EQUIPMENT, AND SYSTEMS THAT
ARE TO REMAIN ARE NOT DAMAGED. PROVIDE PROTECTION
AS NEEDED TO ENSURE THAT THESE ITEMS ARE NOT
DAMAGED.
3.SEE MEP DRAWINGS FOR THOSE REMOVALS. ALL
ABANDONED WIRING, PIPING AND EQUIPMENT SHALL BE
REMOVED EXCEPT THOSE IN EXISTING WALL AND SLABS
THAT ARE TO REMAIN. PROPERLY CAP AND/OR TERMINATE
ABANDONED PIPING AND WIRING THAT REMAINS.
4.ERECT NEW TEMPORARY PARTITIONS UP TO DECK ABOVE AS
REQUIRED BY NFPA 241, SECTION 8.6.2.1 WITH A MINIMUM OF
1-HOUR RATING AND SMOKE TIGHT. COMPLY WITH THE JOINT
COMMISSIONS STANDARDS AND AS REQUIRED TO PROTECT
ADJACENT SPACES FROM DUST MIGRATION. PROVIDE AND
INSTALL RATED (45MIN) AND SEALED ACCESS DOORS AS
REQUIRED FOR STAGING AND PHASING, COMPLETE WITH ALL
REQUIRED HARDWARE AND CLOSURES. ALL EXISTING
PENETRATIONS TO BE SEALED AND TEMPORARY FIRE/SMOKE
DAMPERS INSTALLED AT ALL DUCT PENETRATIONS AT LINE
OF NEW TEMPORARY WALL. CUT AND PATCH AS REQUIRED
ALL EXISTING FINISHES TO INSTALL NEW TEMPORARY
CONSTRUCTION SEPARATION WALLS. CONTRACTOR TO
PATCH AND REPAIR ALL EXISTING
SURFACES/FINISHES/CONSTRUCTION AS REQUIRED WHEN
TEMPORARY WALLS ARE REMOVED AT COMPLETION OF
PROJECT. COORDINATE WITH PHASING/ICRA DRAWINGS TO BE
MINIMUM OF STC 50 RATING.
5.GENERAL CONTRACTOR IS TO NOTIFY THE ARCHITECT/VA
IMMEDIATELY FOLLOWING FINDING PIPING, CHASES,
DUCTWORK, ETC. WITHIN THE WALLS TO BE DEMOLISHED
THAT WILL CAUSE CHANGE IN DESIGN.
6. ALL CONSTRUCTION DEBRIS TO BE REMOVED AFTER 5PM IF
USING ELEVATOR. ALL DEBRIS SHALL BE REMOVED IN A
COVERED BUGGY. COORDINATE WITH C.O.R. AND REFER TO
PHASING/ICRA DRAWING FOR ADDITIONAL INFORMATION.
7.USE OF A JACK HAMMER IS NOT PERMITTED.
8.COORDINATE WITH VA C.O.R. FOR AFTER HOURS WORK FOR
ALL NOISY (HIGH DECIBEL) WORK.
9.COORDINATE WITH VA C.O.R. FOR AFTER HOURS WORK TO
REMOVE EXISTING MATERIALS; USE OF A JACK HAMMER IS
NOT PERMITTED.
10. COORDINATE ALL DEMOLITION WORK WITH ASBESTOS
ABATEMENT WORK.
11. ALL WALL MOUNTED POSTERS, POSTER BOARDS,
ARTWORK, PHOTOGRAPHS AND SIGNAGE TO BE CAREFULLY
REMOVED AND RETURNED TO THE VA C.O.R. FOR RE-USE.
DEMOLITION NOTES
DEMOLITION PLAN LEGEND
EXISTING PARTITION
TO BE DEMOLISHED
EXISTING DOOR TO
BE DEMOLISHED
EXISTING PARTITION
TO REMAIN
EXISTING DOOR
TO REMAIN
F i l e
N a m e
C
U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h
V
A
W e s t
H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t
A
S D
D a t e
W e d
J a m e l s c h l e m o w i t z
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% SUBMISSION
DEMOLITION PLAN
DEMOLITION CEILING PLAN
1-AS-D100
DEMOLITION KEYNOTES
Number Note
1 TEMPORARY PARTITIONS, SEE GENERAL DEMOLITION NOTE #4.
REMOVE EXISTING INTERIOR PARTITION COMPLETE. CUT, PATCH
AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED FOR
SURFACES TO BE FLUSH & MATCH EXISTING.
CONTRACTOR TO REMOVE EXISTING EQUIPMENT. BSC
CABINETS, LAMINAR FLOW HOODS TO BE REUSED IN THE NEW
FLOOR PLAN, COORDINATE AS REQUIRED.
REMOVE EXISTING FLOORING AND CLEAN AND PREP FOR NEW
FLOORING. CUT, PATCH AND REPAIR ADJACENT FINISHES TO
REMAIN AS REQUIRED.
REMOVE EXISTING CEILING SYSTEM COMPLETELY. CUT, PATCH
AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED.
REMOVE EXISTING DOOR AND FRAME COMPLETE. CUT, PATCH
AND REPAIR ADJACENT FINISHES AS REQUIRED.
CONTRACTOR TO REMOVE EXISTING EQUIPMENT AND PROVIDE
TO VA.
REMOVE EXISTING WINDOW AND FRAME COMPLETE. CUT, PATCH
AND REPAIR ADJACENT FINISHES AS REQUIRED. SEE FLOOR PLAN
FOR AREAS TO RECEIVE NEW INFILL FRAMING AND PREPARE
OPENING TO RECEIVE NEW INFILL. INFILL TO BE FLUSH WITH
EXISTING WALL.
REMOVE EXISTING PLUMBING FIXTURES COMPLETE AND CAP OFF
ALL LINES. CUT, PATCH AND REPAIR ADJACENT FINISHES TO
REMAIN AS REQUIRED.
REMOVE EXISTING COUNTER/WALL CASEWORK AND LOCKERS
COMPLETE. PATCH AND REPAIR ADJACENT FINISHES AS REQUIRED.
REMOVE EXISTING CEILING SYSTEM AND INSTALL NEW CEILING
SYSTEM AS REQUIRED TO INSTALL NEW MEP WORK. CUT, PATCH
AND REPAIR ADJACENT FINISHES TO REMAIN AS REQUIRED.
REMOVE EXISTING FRAMED WALL AND GYPSUM BOARD FINISH.
EXISTING MECHANICAL UNITS TO BE REMOVED. SEE MEP
DRAWINGS. TYPICAL.
REMOVE EXISTING WINDOW COMPLETE. PREPARE SURFACE TO
RECEIVE NEW WINDOW.
SYMBOL
"CONTRACTOR TO INSTALL NEW TEMPORARY PAINTED HOLLOW
MTL FRAME AND DOOR PAIR (CLEAR OPENING OF AT LEAST 6'x
HEIGHT OF EXIST WINDOW FRAME, V.I.F) FOR PHASE I ENTRY
FROM THE EXTERIOR AS LOCATED ON DRAWING 1-AS-D100. THIS
PAIR OF DOORS PROVIDED BY THE CONTRACTOR W/ ALL REQ'D
HARDWARE & LOCKING DEVICES TO SECURE THE BUILDING
ENVELOPE FOR WEATHER TIGHTNESS AND SECURITY PURPOSES
AND PROVIDE PROPER ACCESS FOR THE CONTRACTOR TO THE
PROJECT AREA (MORTISE STOREROOM LOCKSET AND CLOSER,
ETC...). CONTRACTOR TO PROVIDE TEMPORARY ACCESS STAIRS
AS REQ'D TO PROPERLY ACCESS THE TEMPORARY DOORS AND
MEET ALL OF THE CODE REQUIREMENTS."
CONTRACTOR TO INSTALL NEW (1HR) RATED SHAFTWALL UP TO
DECK ABOVE ON EXISTING PARTITION FOR CONST. SEPARATION
PRIOR TO OTHER CONSTRUCTION.
AutoCAD SHX Text
CHEMO ROOM
AutoCAD SHX Text
ANTE ROOM
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
CLEAN PREP.
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
HAC
AutoCAD SHX Text
MOP SINK
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VAMC, WEST HAVEN, CT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Approved: Project Manager
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Service Chief
AutoCAD SHX Text Project Title
AutoCAD SHX Text Location
AutoCAD SHX Text Building Number
AutoCAD SHX Text
VAMC, WEST HAVEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Project No.
AutoCAD SHX Text Date
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
VA
AutoCAD SHX Text Veterans Affairs
AutoCAD SHX Text Department of
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text A
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-11-19
AutoCAD SHX Text 689-17-002
AutoCAD SHX Text
VA
AutoCAD SHX Text
WEST HAVEN, CT
AutoCAD SHX Text
INPATIENT PHARMACY IV
AutoCAD SHX Text
CONNECTICUT
AutoCAD SHX Text
HEALTHCARE
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
VA
AutoCAD SHX Text
STAMP:
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
AutoCAD SHX Text
CORRECTIONS
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
CT PROFESSIONAL ENGINEER NO. 25337
AutoCAD SHX Text
JOHN D. FELLENZER, P.E.
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AREA OF WORK FIRST FLOOR BLDG 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTE: SEE PHASING PLANS FOR EXITING/ACCESS DURING CONSTRUCTION AND TEMPORARY BARRIERS. SEE PHASING/ICRA PLANS FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLITION PLAN - GROUND FLOOR
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLITION CEILING PLAN - GROUND FLOOR
AutoCAD SHX Text NOTE: 1. EXISTING FLOORING - SEAMLESS TYPE SHEETGOODS. EXISTING FLOORING - SEAMLESS TYPE SHEETGOODS. 2. EXISTING WALLS - GYPSUM BOARD AND STUDS. EXISTING WALLS - GYPSUM BOARD AND STUDS. 3. DEMOLITION AND ALL "LOUD" CONSTRUCTION WORK TO DEMOLITION AND ALL "LOUD" CONSTRUCTION WORK TO BE COMPLETED DURING OFF HOURS (NIGHT SHIFT).
NOTE: 1. EXISTING CEILING - PLASTIC CEILING TILES AND GRID.EXISTING CEILING - PLASTIC CEILING TILES AND GRID.
EXIST ELECTRICAL PANELS
4'-0"
CLEAR
3'- 9"
'-3
LAMINAR
FLOW HOOD
LAMINAR
FLOW HOOD
SHELVING
HW SINK
STERILE SIDE
DE
MA
RC
AT
IO
N
LIN
E
'-6
18'-11 1/2"
33'-7" 20'-2"
'-3
4'-
2 1 /2"
'-2
1/ 2"
ENTRY
6'-6"
EXISTING ENTRY
TO PHARMACY
PR
IN
TE
R
REF
MOBILE
CART
EW
BSC
3'- 6"
MI
N
MOBILE
CART
6' SHELVING
WORK STATION
8'-0"
REF
REFBSC
MOBILE
CART
MOBILE
CART
MOBILE
CART
DOFFING ZONE
FREEZER
BELOW
MOBILE
CART
4'-0"
BE
NC
H
6' SHELVING6' SHELVING6' SHELVING
8 1/2"
4'-0"
TR
AS
H
BI
N
TR
AS
H
BI
N
TR
AS
H
BI
N 4' LONG
SHELVING
BENCH
MOBILE
CART
MOBILE
CART
MOBILE
CART
TR
AS
H
BI
N
TR
AS
H
BI
N
18'-5 1/2"
DIRTY SIDE
COMP. ST.
COMP. ST.
MOBILE
WORK
COUNTER
MOBILE
CART
MOBILE
CART
MOBILE
CART
MOBILE
CART
MOBILE
CART
MOBILE
CART
3'- 5"
SHELVING
4'- 8 1
/2"
3'- 2"
3'-2"
2'-
TRASH
BIN
3'-3 1/2"
6'
SH
EL
VI
NG
6' SHELVING
2'- 7"
6'
SH
EL
VI
NG
MOBILE
CART
MOBILE
CART
MOBILE
CART
4'-1"
5'
SH
EL
VI
NG
MOBILE
WORK
COUNTER
2'- 6"
3'- 9"
5'-0"
REF
REF
SPLASH GUARD
1'- 9 1
/2"
8'-3"
3'- 2"
4'-0"
4'- 1 1
/2"
FEC
PASS-THRU
SEE NOTE #3
LIGHT BOX
LOCATION
EXISTING WINDOW
TO BE TINTED
EXISTING WINDOW
TO BE TINTED
EXISTING WINDOW
TO BE TINTED
EXISTING WINDOW
TO BE TINTED
LIGHT BOX
LOCATION
SECURITY
INTELLI-KEY PAD
LOCATION
FIRE/SMOKE RATING
(SEE 3-AS-500 FOR
PARTITION LEGEND)
NOMINAL SIZE
SPECIFICATION
CATEGORY
SEQUENCE NUMBER
DOOR NUMBER
DOOR SIZE (SEE
3-AS-600 FOR DOOR
SIZE LEGEND)
VIEW NUMBER
SHEET NUMBER
VIEW
NUMBER
SHEET
NUMBER
VIEW
NUMBER
SHEET
NUMBER
x-x-xx
3-AS-000
3-AS-00
NEW WALL AND DOOR
EXISTING WALL AND
DOOR TO REMAIN
NEW DOOR TAG
NEW PARTITION TAG
NEW WALL
SECTION TAG
NEW DETAIL
CALLOUT TAG
NEW INTERIOR
ELEVATION TAG
3-AS-000
000 EQUIPMENT TAG
STERILE SIDE
ENTRY
EXISTING ENTRY
TO PHARMACY
DIRTY SIDE
2'- 7 1
/2" 3'-
0 1 /2"
8'- 2"
2'-11"
9"
14'-8 1/2" 4 1 /2"
1'- 7"
1'- 0 1
/2"
12'-0" 2'-8 1/2" 4'-4" 8'-11" 8'-4 1/2" 3'-5" 3'-8"
8 1/2"
2'-3 1/2"
10 1/2"
1'- 6"
2'- 2"
3'- 6 1
/2"
4 1 /2"
2'- 4"
3'-
1/ 2"
7'- 5"
1'- 8"
1'-6"
1'-6" 13'-2 1/2" 4'-4" 9'-0"
4'-11 1/2" 9 1/2"
5'-3 1/2" 6'-8 1/2"
8'- 0"
8'-6"
5 1 /2"
1'-11"
3'- 0"
8'- 0"
2'-0"8'-0"
3'-6" CLEAR OPENING
3'-8" CLEAR OPENING
3'-6" CLEAR OPENING
3'-6" CLEAR
OPENING
6'-10 1/2"
17'-1"
'-3
1/ 2"
V
IF
'-3
33'-8" 1'-5 1/2" 20'-2 1/2"
13'-6" 3'-3 1/2"
2'- 5"
5'- 0"
2'- 7 1
/2" 8'-
8"
4'-0 1/2"18'-9"
3'-0"
9-4-3s
9-4-5
9-4-3s 9-4-4s
9-4-4s
9-4-4s
5'-
4'- 2 1
/2"
1'-4 1/2"
5'-2" 2'-5" 2'-10 1/2"
4 1 /2"
9-4-3sSIM
9-4-4s
TYP FEC
1'- 5 1
/2"
APPROX 24" HIGH CRAWL SPACE
NOTE: CUT/PATCH AND MODIFY AS
REQ'D FOR NEW PLUMBING WORK. DO
NOT DISTURB AREAS NEAR EXISTING
FOUNDATIONS/STRUCTURE.
STERILE SIDE
ENTRY
EXISTING ENTRY
TO PHARMACY
DIRTY SIDE
FEC
FEC
WALL MOUNTED FIRE
EXTINGUISHER
S
REFLECTED CEILING PLAN LEGEND
NEW 2'X2' CEILING GRID AND
CEILING TILES. REFER TO
ROOM FINISH SCHEDULE.
NEW ABUSE-RESISTANT, TYPE 'X'
GYPSUM BOARD CEILING
NEW 2'X2'
LIGHT FIXTURE
NEW 1'X4'
LIGHT FIXTURE
NEW SUPPLY
DIFFUSER
NEW RETURN
GRILLE
NEW FIRE SPRINKLER
NEW CEILING MOUNTED
OCCUPANCY SENSOR
NEW CEILING MOUNTED
DIRECTIONAL EXIT SIGN
NEW SMOKE DETECTOR.
SEE MEP DRAWINGS.
F i l e
N a m e
C
U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h
V
A
W e s t
H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t
A
S
D a t e
W e d
J a m e l s c h l e m o w i t z
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% SUBMISSION
PROPOSED DIMENSION PLAN
PROPOSED FLOOR PLAN
PROPOSED REF. CLG. PLAN
1-AS-100
1-AS-600
AutoCAD SHX Text 222A
AutoCAD SHX Text 41"
AutoCAD SHX Text
STERILE
AutoCAD SHX Text
STOR/PREP
AutoCAD SHX Text
AutoCAD SHX Text
242 SF
AutoCAD SHX Text
ANTE-ROOM
AutoCAD SHX Text
AutoCAD SHX Text
358 SF
AutoCAD SHX Text
HOUSE
AutoCAD SHX Text
KEEPING
AutoCAD SHX Text
AutoCAD SHX Text
18 SF
AutoCAD SHX Text
STERILE HD
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
313 SF
AutoCAD SHX Text
STERILE NON-HD
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
205 SF
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
250 SF
AutoCAD SHX Text 223A
AutoCAD SHX Text 41"
AutoCAD SHX Text 224A
AutoCAD SHX Text 34"
AutoCAD SHX Text 226A
AutoCAD SHX Text 41"
AutoCAD SHX Text 225A
AutoCAD SHX Text 44"
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
AutoCAD SHX Text
66 SF
AutoCAD SHX Text 105A
AutoCAD SHX Text 36"
AutoCAD SHX Text N#
AutoCAD SHX Text X
AutoCAD SHX Text
FLOOR PLAN LEGEND
AutoCAD SHX Text
STERILE
AutoCAD SHX Text
STOR/PREP
AutoCAD SHX Text
AutoCAD SHX Text
242 SF
AutoCAD SHX Text
ANTE-ROOM
AutoCAD SHX Text
AutoCAD SHX Text
358 SF
AutoCAD SHX Text
HOUSE
AutoCAD SHX Text
KEEPING
AutoCAD SHX Text
AutoCAD SHX Text
18 SF
AutoCAD SHX Text
STERILE HD
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
313 SF
AutoCAD SHX Text
STERILE NON-HD
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
205 SF
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
250 SF
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
AutoCAD SHX Text
66 SF
AutoCAD SHX Text
AS400
AutoCAD SHX Text 4-A
AutoCAD SHX Text 4-B
AutoCAD SHX Text 4-C
AutoCAD SHX Text 4-D
AutoCAD SHX Text
AS400
AutoCAD SHX Text 1-A
AutoCAD SHX Text 1-B
AutoCAD SHX Text 1-C
AutoCAD SHX Text 1-D
AutoCAD SHX Text
AS400
AutoCAD SHX Text 3-A
AutoCAD SHX Text 3-B
AutoCAD SHX Text
AS400
AutoCAD SHX Text 5-C
AutoCAD SHX Text 4-D
AutoCAD SHX Text 5-A
AutoCAD SHX Text 4-B
AutoCAD SHX Text
AS400
AutoCAD SHX Text
AutoCAD SHX Text
STERILE
AutoCAD SHX Text
STOR/PREP
AutoCAD SHX Text
AutoCAD SHX Text
242 SF
AutoCAD SHX Text
ANTE-ROOM
AutoCAD SHX Text
AutoCAD SHX Text
358 SF
AutoCAD SHX Text
HOUSE
AutoCAD SHX Text
KEEPING
AutoCAD SHX Text
AutoCAD SHX Text
18 SF
AutoCAD SHX Text
STERILE HD
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
313 SF
AutoCAD SHX Text
STERILE NON-HD
AutoCAD SHX Text
BUFFER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
205 SF
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
250 SF
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
AutoCAD SHX Text
66 SF
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VAMC, WEST HAVEN, CT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Approved: Project Manager
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Service Chief
AutoCAD SHX Text Project Title
AutoCAD SHX Text Location
AutoCAD SHX Text Building Number
AutoCAD SHX Text
VAMC, WEST HAVEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Project No.
AutoCAD SHX Text Date
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
VA
AutoCAD SHX Text Veterans Affairs
AutoCAD SHX Text Department of
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text A
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-11-19
AutoCAD SHX Text 689-17-002
AutoCAD SHX Text
VA
AutoCAD SHX Text
WEST HAVEN, CT
AutoCAD SHX Text
INPATIENT PHARMACY IV
AutoCAD SHX Text
CONNECTICUT
AutoCAD SHX Text
HEALTHCARE
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
VA
AutoCAD SHX Text
STAMP:
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
AutoCAD SHX Text
CORRECTIONS
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
CT PROFESSIONAL ENGINEER NO. 25337
AutoCAD SHX Text
JOHN D. FELLENZER, P.E.
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AREA OF WORK FIRST FLOOR BLDG 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
PROPOSED FLOOR PLAN - GROUND FLOOR
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
PROPOSED DIMENSION PLAN - GROUND FLOOR
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
CRAWL SPACE
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
PROPOSED REFLECTED CEILING PLAN - GROUND FLOOR
AutoCAD SHX Text ALTERATION NOTES: 1. EXISTING WINDOWS TO BE TINTED.INSTALL EXISTING WINDOWS TO BE TINTED.INSTALL NEW SHADING FILM AT EXTERIOR SIDE. 2. LEVEL FLOOR AS REQ'D FOR NEW FLOOR LEVEL FLOOR AS REQ'D FOR NEW FLOOR FINISHES (TYPICAL). 3. CONTRACTOR TO RESET FRAME OF EXISTING CONTRACTOR TO RESET FRAME OF EXISTING FLOOR ACCESS DOOR AS REQUIRED TO MAKE DOOR FLUSH WITH SURROUNDING FLOOR. IN ADDITION, CONTRACTOR TO INSTALL NEW CEMENTITIOUS LEVELING COMPOUND TO CREATE FLUSH TRANSITION. 4. THE CONTRACTOR SHALL FULLY CAULK AND THE CONTRACTOR SHALL FULLY CAULK AND SEAL ALL JOINTS IN THE INTERIOR SIDE OF THE EXTERIOR WALLS AND AT ALL INTERIOR PARTITIONS OF THE WORK AREA, AROUND ALL RECEPTACLES, AND AROUND ALL MECHANICAL OPENINGS AND PENETRATIONS.
AutoCAD SHX Text
1. ALL NEW ACT CEILING SYSTEMS ARE TO BE ALL NEW ACT CEILING SYSTEMS ARE TO BE INSTALLED MEETING ALL SEISMIC REQUIREMENTS FOR ASCE 7-05 SEISMIC DESIGN CATREGORY "C", ASTM C635, ASTM 636 AND CISCA FOR SEISMIC ZONE 0-2, FRICTION CLIPS SHALL NOT BE USED, MINIMUM 12 GA. WIRE, 7/8" PERIMETER CLOSEURE ANGLE WIDTH AND ALL OTHER REQUIREMENTS.
CEILING NOTES:
AREA OF EXISTING ROOF WHERE
CONTRACTOR IS TO REMOVE EXISTING
CURB AND RTU. AFTER REMOVAL, INSTALL
NEW METAL DECK, NEW INSULATION
(TAPERED) AND ROOFING TO MATCH
EXISTING.
AFTER REMOVAL OF EXISTING CURB;
CONTRACTOR TO PROVIDE AND INSTALL
NEW INFILL ROOF DECK CONSTRUCTION
WITH GALVANIZED CORRUGATED ROOF
DECK (MATCH EXISTING) AND 10" DP
COLD FORMED FRAMING (18 GA) TO
MATCH EXISTING. AREA OF NEW ROOF
DECK TO THEN BE REROOFED
(INSULATION, EPDM, FLASHING) AS REQ'D
TO MATCH EXISTING.
NOTE:
TYPICALLY INDICATES A NEW EXHAUST
DUCT PENETRATION (17 TOTAL)
CONTRACTOR TO PROVIDE AND INSTALL
NEW (12" HIGH MIN) SQUARE METAL CURB
(AND P.T. WOOD NAILERS AND BLOCKING AS
REQ'D) AND FULLY FLASH TO THE EXISTING
ROOF MEMBRANE. COORDINATE WITH
MECHANICAL DRAWINGS. PROVIDE WITH
FULLY SEALED STAINLESS STEEL CAP
FLASHING/COUNTER FLASHING.
NOTE:
CONTRACTOR TO PROVIDE AND INSTALL
NEW (12" HIGH MIN) SQUARE METAL CURB
FOR MECHANICAL UNITS (AND P.T. WOOD
NAILERS AND BLOCKING AS REQ'D) AND
FULLY FLASH TO THE EXISTING ROOF
MEMBRANE. COORDINATE WITH
MECHANICAL DRAWINGS. PROVIDE WITH
FULLY SEALED STAINLESS STEEL CAP
FLASHING/COUNTER FLASHING.
NOTE:
SEE MECHANICAL DRAWINGS FOR EXTENT
OF NEW DUCTWORK. CONTRACTOR TO
PROVIDE SEPARATION/PROTECTION
MEMBRANE UNDER ALL NEW SUPPORTS.
(TYPICAL)
MODIFY EXISTING ROOF, COORDINATE AS REQ'D.
NTS PROVIDE AT ALL PENTRATIONS
PIPE RAIL & VTR PENETRATION FLASHING DETAIL
F i l e
N a m e
C
U s e r s l s c h l e m o w i t z a p p d a t a l o c a l t e m p A c P u b l i s h
V
A
W e s t
H a v m p o u n d i n g i t e F l o o r P l a n d a y o u t
A
S
D a t e
W e d
J a m e l s c h l e m o w i t z
ENGINEERING LLP
www.fellp.com
181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704 fx 855-320-8735
22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481 fx 845-343-4986
FE PROJECT #: 18-077
Liscum
181 CHURCH STREET
POUGHKEEPSIE, NEW YORK 12601
PHONE 845-452-2268 FAX 845-452-3752
ARCHITECTURE
PLANNING INTERIORS
McCormack VanVoorhis LLP
100% SUBMISSION
PROPOSED ROOF PLAN
1-AS-101
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
RTU - 2
AutoCAD SHX Text
RTU - 1
AutoCAD SHX Text
RTU - 4
AutoCAD SHX Text
RTU - 3
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text NOTE: PIPES TO BE ANCHORED TO BOTTOM OF ROOF DECK OR CONCRETE PLANKING TO ASSURE STABILITY
AutoCAD SHX Text
SPLICING CEMENT
AutoCAD SHX Text
PREMOLDED PIPE SEAL 8" HIGH MIN
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
WATER CUT-OFF MASTIC
AutoCAD SHX Text
S.S. CLAMP RING
AutoCAD SHX Text
RIGID INSULATION
AutoCAD SHX Text
MEMBRANE
AutoCAD SHX Text
LAP SEALANT
AutoCAD SHX Text
LAP SEALANT
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
INSEAM SEALANT( LOCATE 1/2" FROM INSIDE EDGE OF PIPE SEAL FLANGE)
AutoCAD SHX Text NOTE: PRE-MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE REGARDLESS OF PIPE DIAMETER
AutoCAD SHX Text
METAL DECK. VERIFY IN FIELD
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VAMC, WEST HAVEN, CT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Approved: Project Manager
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Service Chief
AutoCAD SHX Text Project Title
AutoCAD SHX Text Location
AutoCAD SHX Text Building Number
AutoCAD SHX Text
VAMC, WEST HAVEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text Project No.
AutoCAD SHX Text Date
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
VA
AutoCAD SHX Text Veterans Affairs
AutoCAD SHX Text Department of
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text A
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-11-19
AutoCAD SHX Text 689-17-002
AutoCAD SHX Text
VA
AutoCAD SHX Text
WEST HAVEN, CT
AutoCAD SHX Text
INPATIENT PHARMACY IV
AutoCAD SHX Text
CONNECTICUT
AutoCAD SHX Text
HEALTHCARE
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
VA
AutoCAD SHX Text
STAMP:
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
AutoCAD SHX Text
CORRECTIONS
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text UNAUTHORIZED ALTERATION OR ADDITION TO A PLAN BEARING A LICENSED PROFESSIONAL ENGINEER'S SEAL IS A VIOLATION OF STATE EDUCATION LAW.
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
CT PROFESSIONAL ENGINEER NO. 25337
AutoCAD SHX Text
JOHN D. FELLENZER, P.E.
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AREA OF WORK FIRST FLOOR BLDG 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
PROPOSED ROOF PLAN
ROOF PLAN LEGEND
STERILE SIDE
ENTRY
EXISTING ENTRY
TO PHARMACY
DIRTY SIDE
L2280
R6060
M2080
L2280
R6060
R6060
R6060
R6060
M2080 M2080 M2080
M2080
M2080
M2080
M2
M2
F2
F2
F2
F2
F2
F2
F0
F0
F0535 K1910
M2
K1910
F0535
F0535 F0535
F0535 F0535
F0535
F0
F0
F0
F0535
P1965 A5075F0535
U1200
FEC
F0535F0535F0535
F0
F0
A
D
B B B
B
B B
C
A A A
B
LB1
LB1
PRINTER
PRINTER
P2451
A1014U3500EXU3500EX
UCFRZ
A1014
UPE01A
UPE01A
A1014
A5145
P3000
CA040
A1014
A1014
UPE01
FURNITURE AND
EQUIPMENT BY VA
NEW WALL AND DOOR
EXISTING WALL AND
DOOR TO REMAIN
000 EQUIPMENT TAGPHARMACY EQUIPMENT SCHEDULE
EQUIPMENT LIST
JSN NAME AI QTY DESCRIPTION
A1014 WALL MOUNTED PHONE V/V 5 TELEPHONE, WALL MOUNTED, I LINE WITH SPEAKER
A5075 DISPENSER SOAP,
DISPOSABLE V/V 2
DISPOSABLE SOAP DISPENSER, ONE-HANDED
DISPENSING OPERATION. DESIGNED TO ACCOMMODATE
DISPOSABLE SOAP CARTRIDGE AND VALVE
A5077 DISPENSER, HAND
SANITIZER, HANDS-FREE V/V 6
A TOUCH FREE WALL-MOUNTED HAND SANITIZER
DISPENSE. DOES NOT INCLUDE SANITIZING LIQUID.
BATTERY OPERATED
A5100 SHOE COVER
DISPENSER, SMALL V/V 2 A SHOE COVER DISPENSER, THAT HOLDS UP TO 55 PAIRS
OF SHOE COVERS
A5145
HOOK, GARMENT,
DOUBLE, SS, SURFACE
MOUNTED
C/C 2
SURFACE MOUNTED, SATIN FINISH STAINLESS STEEL,
DOUBLE GARMENT HOOK, EQUIPPED WITH A CONCEALED
MOUNTING BRACKET THAT IS SECURED TO A CONCEALED
WALL PLATE
CA040
CABINET, OPEN, W/H, 2
SHELF, SLOPING
TOP38"X24"X13"
C/C 1
WALL OPEN OPEN FRONT CABINET, STAINLESS STEEL
CONSTRUCTION WITH SLOPED TOP AND TWO
ADJUSTABLE SHELVES
F0535 CART, UTILITY V/V 12 STAINLESS STEEL UTILITY CART, 40" HIGH X 36" WIDE X
24" DEEP WITH 4 HEAVY DUTY CASTER WHEELS
F2010 BASKET WASTE PAPER,
STEP ON V/V # STEP-ON WASTEPAPER BASKET WITH INNER LINER AND
FOOT PETAL ACTIVATED FLIP TOP, 36" X 15"
F2245
CAMERA, VIDEO
SURVEILLANCE, HD, IP
POWERED
V/V #
A HIGH DEFINITION, FULL FUNCTIONAL VIDEO
SURVEILLANCE CAMERA, CAPABLE OF FULL 1080P
RESOLUTION AT 30 FRAMES PER SECOND WHILE
OPTIMIZING NETWORK USAGE WITH H.264, MEPG-4 AND
JPEG COMPRESSION FORMATS.
M2080A
SHELVING STORAGE,
SOLID, STAINLESS STEEL
WITH ADJUSTABLE
SHELVES AND CASTERS
V/V 1 METRO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.