36C10G25R0044.docx
DOCX document 32 KB Posted
- Solicitation number
- 36C10G25R0044
About this file
This is a Combined Synopsis/Solicitation Notice issued by the Department of Veterans Affairs (VA) for Endoscope Drying and Storage Cabinets - Vertical. The solicitation (36C10G25R0044) seeks a single-award Requirements contract for brand name or equal commercial items, specifically Steris Endodry Endoscope Drying and Storage Cabinets. The procurement is for nationwide VA medical centers, with 74 line items covering cabinets, accessories, connectors, installation, and service options for various endoscope types.
Key details include a base 12-month contract period with four 12-month option years, FOB destination delivery, and firm-fixed pricing. The solicitation is full and open, targeting NAICS code 339113 with a 750-employee size standard. Offers are due by September 16, 2025, at 11:59 PM ET, submitted via email to Contract Specialist Daleta Coles and Contracting Officer Jessica Edwards. The cabinets must meet specific salient characteristics, including HEPA-filtered air purging, vertical storage, expandable scope capacity, endoscope hang time tracking, and a minimum one-year warranty.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C10G26D0003_1.docx | DOCX document | |
| 36C10G25R0044 0002.docx | DOCX document | |
| 36C10G25R0044 0001.docx | DOCX document | |
| ATTACHMENT A PRICE COST SCHEDULE NX EQ Endoscope Cabinets-Vertical Updated 9.16.xlsx | XLSX spreadsheet | |
| ATTACHMENT F - PAST PERFORMANCE REFERENCE - NX EQ Endoscope Cabinets-Vertical .docx | DOCX document | |
| ATTACHMENT C - Contract Clauses NX EQ Endoscope Cabinets-Vertical .docx | DOCX document | |
| ATTACHMENT B - CONTRACT ADMINISTRATION -NX EQ Endoscope Cabinets-Vertical-Resolved.docx | DOCX document | |
| ATTACHMENT G - PAST PERFORMANCE QUESTIONAIRE - NX EQ Endoscope Cabinets-Vertical.docx | DOCX document | |
| ATTACHMENT E - REPORTING TOOL - NX EQ Endoscope Cabinets-Vertical.xlsx | XLSX spreadsheet | |
| ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ Endoscope Cabinets-Vertical .docx | DOCX document | |
| ATTACHMENT A - PRICE COST SCHEDULE NX EQ Endoscope Cabinets-Vertical.xlsx | XLSX spreadsheet |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice
| SUBJECT* |
| NX EQ Endoscope Drying and Storage Cabinets - Vertical |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 22408-2697 |
| SOLICITATION NUMBER* |
| 36C10G25R0044 |
| RESPONSE DATE/TIME/ZONE |
| 09-16-2025 11:59 PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339113 |
| CONTRACTING OFFICE ADDRESS |
| U.S. Department of Veterans Affairs |
OPAL | Strategic Acquisition Center
10300 Spotsylvania Ave | STE 400 Fredericksburg VA 22408-2697
POINT OF CONTACT*
Contract Specialist Daleta Coles Daleta.Coles@va.gov Contracting Officer Jessica Edwards Jessica.Edwards6@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Nationwide |
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| VA | OALC | OPAL | SAC |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Daleta.Coles@va.gov |
| EMAIL DESCRIPTION |
| Daleta Coles, Contract Specialist |
DESCRIPTION
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
Solicitation Number:
36C10G25R0044 Notice Type:
Combined Synopsis/Solicitation Synopsis:
COMBINED SYNOPSIS/SOLICITATION
This is a combined synopsis/solicitation for brand name or equal commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, “Streamlined Procedures for Evaluation and Solicitation for Commercial Items” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; offers are being requested and a written solicitation will not be issued.
Solicitation number 36C10G25R0044 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Proposal (RFP). This combined synopsis/solicitation incorporates provisions and clauses in effect through Federal Acquisition Circular (FAC) 2025-03, dated January 17, 2025.
Requirement Description:
VA has a requirement to purchase ENDOSCOPE DRYING AND STORAGE CABINETS - VERTICAL to deliver patient care at its VA Medical Centers around the country. Endoscope drying and storage cabinets - Vertical are designed to reduce infection risks by removing moisture from endoscopes following high-level disinfection (HLD) and providing a controlled environment in which to store them. These cabinets are typically manufactured using materials (e.g., stainless steel, polypropylene, acrylic) that permit ease of cleaning. Endoscope drying storage cabinets circulate clean air using a high-efficiency particulate-air (HEPA) filter, exhausting the air back into the room through an activated carbon filter. In addition to circulating air within the cabinet, continuous filtered air is forced through the endoscope channels to purge water eliminating bacterial proliferation during vertical storage from their control body. Additionally, some drying storage cabinets allow for user and endoscope tracking and data export to help prevent endoscope handling by unauthorized personnel, to track compliance with endoscope management policies, to facilitate contact tracing in cases of possible cross-contamination, and to prevent theft.
A single award Requirements contract will be awarded IAW FAR 52.211-6 Brand Name or Equal in accordance with all terms, conditions, provisions, specifications, and schedule of this solicitation herein. Offers shall contain the terms for cost/price and technical capabilities of the brand name or equal equipment. The Government reserves the right to award without discussions.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 – Surgical Appliance and Supplies Manufacturing: 6515 – Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 750 employees. This procurement action is issued as Full and Open.
This acquisition is for a single award Requirements contract in accordance with FAR Part 16.5 for Steris ® brand name or equal ENDOSCOPE DRYING AND STORAGE CABINETS - VERTICAL and related equipment and accessories as identified in ATTACHMENT A – PRICE COST SCHEDULE - NX EQ ENDOSCOPE CABINETS - VERTICAL. All interested companies shall provide a offer for all Contract Line-Item Numbers (CLINs) listed in ATTACHMENT A – PRICE COST SCHEDULE - NX ENDOSCOPE CABINETS - VERTICAL and paragraph 2 below.
The ordering period is for one 12-month base year with four 12-month option years. Delivery is FOB destination Firm-Fixed Price Orders will be placed against this contract in writing and will provide the delivery locations, delivery dates and exact quantities.
The FAR provision at 52.212-1, Instructions to Offerors – Commercial Products and Commercial Services, applies to this acquisition including attached addenda (ATTACHMENT D) to the provision.
The FAR provision at 52.212-2, Evaluation -- Commercial Products and Commercial Services, and the specific evaluation criteria as attached addenda (ATTACHMENT D) also applies to this acquisition.
The Offeror is to include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Products and Commercial Services, with its offer.
Clause at 52.212-4, Contract Terms and Conditions -- Commercial Products and Commercial Services, applies to this acquisition and a statement regarding any addenda to the clause. Addendum is attached (ATTACHMENT C).
Clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Products and Commercial Services, applies to this acquisition and a statement regarding which, if any, of the additional FAR clauses cited in the clause are applicable to the acquisition. Addendum is attached (ATTACHMENT C).
All interested offerors must be registered in the System for Award Management (SAM) prior to submitting a offer. You may access SAM at https://sam.gov/SAM/.
Questions regarding this combined synopsis/solicitation are due via email by 11:59 PM ET on September 09, 2025, to Contract Specialist, Daleta Coles at daleta.coles@va.gov and Contracting Officer, Jessica Edward at jessica.edwards6@va.gov. No calls will be accepted.
Offers are due via email by 11:59 PM ET on September 16, 2025, to Contract Specialist, Daleta Coles at daleta.coles@va.gov and Contracting Officer, Jessica Edwards at jessica.edwards6@va.gov.
1. SCOPE OF WORK
The Veterans Health Administration (VHA) Non-Expendable Equipment (NX) National Program has identified the ENDOSCOPE DRYING AND STORAGE CABINETS - VERTICAL product line as a candidate for inclusion in the National Equipment Catalog (NEC). This will be accomplished via the awarding of a VA-wide (otherwise referred to as “national”) single award Requirements contract.
The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide ENDOSCOPE DRYING AND STORAGE CABINETS - VERTICAL to be used by clinicians throughout the VA medical centers and facilities. The period of performance is for a base of 12-months with four 12-month option periods.
2. REQUIREMENT
This requirement will be IAW FAR clause 52.211-6, “Brand Name or Equal” (BNOE) which requires the Offeror to indicate that each product is being offered as an “equal” product to the Steris® Endodry ENDOSCOPE DRYING AND STORAGE CABINETS - VERTICAL. For each equal product, the Offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The Offeror must also clearly identify the item by brand name (if any) and make/model number. Finally, the Offeror must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.
| Contract Line Item# |
| Brand |
| Part Number |
| Description |
| 0001 |
| Steris |
| REL650012EM |
| 6500 SER HEPA DRYING CBNT, 12 SCOPE EXPANSION UNIT |
| 0002 |
| Steris |
| REL650012MU |
| 6500 SER HEPA DRYING CBNT, 12 SCOPE MAIN UNIT |
| 0003 |
| Steris |
| REL650020EM |
| 6500 SER HEPA DRYING CBNT, 20 SCOPE EXPANSION UNIT |
| 0004 |
| Steris |
| REL650020MU |
| 6500 SER HEPA DRYING CBNT, 20 SCOPE MAIN UNIT |
Reliance Endoscope Drying and Storage Cabinets – Connectors and Accessories
| 0005 |
| Steris |
| REL6500BRONCHHLDR |
| 6500 SER CABINET BRONCHOSCOPE HOLDER |
| 0006 |
| Steris |
| REL6500DEPROTECT |
| 6500 SER CABINET ENDOSCOPE DISTAL END PROTECTOR |
| 0007 |
| Steris |
| REL6500ENDOHGR |
| 6500 SER CABINET ENDOSCOPE HANGER |
| 0008 |
| Steris |
| REL6500ENDOSUPPORT |
| 6500 SER CABINET ENDOSCOPE SUPPORT |
| 0009 |
| Steris |
| REL6500EUSENDOLRG |
| 6500 SER CABINET EUS ENDOSCOPE HOLDER, LARGE |
| 0010 |
| Steris |
| REL6500EUSENDOSML |
| 6500 SER CABINET EUS ENDOSCOPE HOLDER, SMALL |
| 0011 |
| Steris |
| REL6500SEISMICEM |
| RELIANCE 6500 SEISMIC KIT EM |
| 0012 |
| Steris |
| REL6500SEISMICMU |
| RELIANCE 6500 SEISMIC KIT MU |
| 0013 |
| Steris |
| REL6500TEEHOLDER |
| 6500 SER CABINET TEE PROBE HOLDER |
| 0014 |
| Steris |
| REL6500TEESUPPORT |
| 6500 SER CABINET TEE PROBE SUPPORT |
| 0015 |
| Steris |
| RELTSF450ENTER |
| CONNECTOR FOR FUJIFILM 450 SERIES ENTEROSCOPES |
| 0016 |
| Steris |
| RELTSF470BRONCH |
| CONNECTOR FOR FUJIFILM 470 SERIES BRONCHOSCOPES |
| 0017 |
| Steris |
| RELTSF500BRONCH |
| CONNECTOR FOR FUJIFILM 530/580 SERIES BRONCHOSCOPES |
| 0018 |
| Steris |
| RELTSF580DUO |
| CONNECTOR FOR FUJIFILM 580 SERIES DUODENOSCOPE |
| 0019 |
| Steris |
| RELTSF740 |
| CONNECTOR FOR FUJIFILM 740 SERIES GI ENDOSCOPES |
| 0020 |
| Steris |
| RELTSF740AUX |
| CONNECTOR FOR FUJIFILM 740/760 GI ENDOSCOPES WITH AUX CHANNEL |
| 0021 |
| Steris |
| RELTSFEBUS |
| CONNECTOR FOR FUJIFILM SERIES EBUS BRONCHOSCOPES |
| 0022 |
| Steris |
| RELTSFGI1 |
| TUBING SET, FUJI GI |
| 0023 |
| Steris |
| RELTSFGI10 |
| TUBING SET, FUJI GI W AUX ON CH |
| 0024 |
| Steris |
| RELTSFGI11 |
| TUBING SET, FUJI GI W AUX ON CH |
| 0025 |
| Steris |
| RELTSFGI2 |
| TUBING SET, FUJI GI W AUX ON LB |
| 0026 |
| Steris |
| RELTSFGI3 |
| TUBING SET, FUJI GI TWO BIOPSY W JET |
| 0027 |
| Steris |
| RELTSFGI4 |
| TUBING SET, FUJI GI W AUX ON CH |
| 0028 |
| Steris |
| RELTSFGI5 |
| TUBING SET, FUJI GI TWO BIOPSY W IND |
| 0029 |
| Steris |
| RELTSFGI7 |
| TUBING SET, FUJI GI W AUX ON CH |
| 0030 |
| Steris |
| RELTSFGI8 |
| TUBING SET, FUJI GI W AUX ON CH |
| 0031 |
| Steris |
| RELTSFGI9 |
| TUBING SET, FUJI GI W AUX ON CH |
| 0032 |
| Steris |
| RELTSKS1 |
| CONNECTOR FOR KARL STORZ ENDOSCOPE TYPE 1 |
| 0033 |
| Steris |
| RELTSKS2 |
| CONNECTOR FOR KARL STORZ ENDOSCOPE TYPE 2 |
| 0034 |
| Steris |
| RELTSO100BRONCH |
| CONNECTOR FOR OLYMPUS 160/180/190 BRONCHOSCOPES |
| 0035 |
| Steris |
| RELTSO100GI |
| CONNECTOR FOR OLYMPUS 160/180/190 GI ENDOSCOPES |
| 0036 |
| Steris |
| RELTSO100GIAUX |
| CONNECTOR FOR OLYMPUS 160/180/190 GI ENDOSCOPES WITH AUX CHANNEL |
| 0037 |
| Steris |
| RELTSOEBUS |
| CONNECTOR FOR OLYMPUS EBUS BRONCHOSCOPES |
| 0038 |
| Steris |
| RELTSOEUSAUX |
| CONNECTOR FOR OLYMPUS EUS GASTROSCOPE WITH ELEVATOR CHANNEL |
| 0039 |
| Steris |
| RELTSOGIDCC |
| CONNECTOR FOR OLYMPUS DUAL CHANNEL COLONOSCOPE |
| 0040 |
| Steris |
| RELTSOGIDCGAUX |
| CONNECTOR FOR OLYMPUS DUAL CHANNEL GASTROSCOPE WITH AUX CHANNEL |
| 0041 |
| Steris |
| RELTSOGIEUS |
| CONNECTOR FOR OLYMPUS ULTRASOUND GASTROSCOPE |
| 0042 |
| Steris |
| RELTSOHYSTERO |
| CONNECTOR FOR OLYMPUS FLEXIBLE HYSTEROSCOPES |
| 0043 |
| Steris |
| RELTSOINTUBATION |
| CONNECTOR FOR OLYMPUS INTUBATION VIDEOSCOPES |
| 0044 |
| Steris |
| RELTSORHINOLARYNGO |
| CONNECTOR FOR OLYMPUS RHINO-LARYNGOSCOPES |
| 0045 |
| Steris |
| RELTSOURETER |
| CONNECTOR FOR OLYMPUS FLEXIBLE URETEROSCOPES |
| 0046 |
| Steris |
| RELTSPBRONCH |
| CONNECTOR FOR PENTAX SERIES BRONCHOSCOPE |
| 0047 |
| Steris |
| RELTSPBRONCHJ10 |
| CONNECTOR FOR PENTAX J10 SERIES BRONCHOSCOPES |
| 0048 |
| Steris |
| RELTSPEBUS1970K |
| CONNECTOR FOR PENTAX 1970UK EBUS BRONCHOSCOPE |
| 0049 |
| Steris |
| RELTSPEBUSJ10 |
| CONNECTOR FOR PENTAX J10 EBUS BRONCHOSCOPE |
| 0050 |
| Steris |
| RELTSPEUS |
| CONNECTOR FOR PENTAX EUS GASTROSCOPE |
| 0051 |
| Steris |
| RELTSPEUSAUX |
| CONNECTOR FOR PENTAX GI EUS GASTROSCOPE WITH ELEVATOR CHANNEL |
| 0052 |
| Steris |
| RELTSPGI |
| CONNECTOR FOR PENTAX SERIES GI ENDOSCOPES |
| 0053 |
| Steris |
| RELTSPGI380 |
| CONNECTOR FOR PENTAX 380 SERIES GI ENDOSCOPES |
| 0054 |
| Steris |
| RELTSPGIAUX |
| CONNECTOR FOR PENTAX GI ENDOSCOPES WITH AUX CHANNEL |
| 0055 |
| Steris |
| RELTSPGIDC |
| CONNECTOR FOR PENTAX GI ENDOSCOPE DUAL CHANNEL |
| 0056 |
| Steris |
| RELTSPGIDCAUX |
| CONNECTOR FOR PENTAX DUAL CHANNEL GASTROSCOPE WITH AUX CHANNEL |
| 0057 |
| Steris |
| RELTSPSMALLDIAM |
| CONNECTOR FOR PENTAX SMALL DIAMETER ENDOSCOPES |
Install/Deinstall Labor
| 0058 |
| Steris |
| SE071002 |
| INSTALLATION OF RELIANCE ENDOSCOPE 6500 MAIN UNIT |
| 0059 |
| Steris |
| SE071012 |
| INSTALL RELIANCE ENDOSCOPE 6500 EXPANSION UNIT |
| 0060 |
| Steris |
| SE0710021 |
| DEINSTALLATION OF RELIANCE ENDOSCOPE 6500 |
Service/ Labor Only
| 0061 |
| Steris |
| SE0710011 |
| LABOR CARE FOR RELIANCE 6500 (MAIN UNIT ONLY, LABOR ONLY) |
| 0062 |
| Steris |
| SE0710011028 |
| 2 YRS OF LABOR CARE FOR REL 6500 (MAIN UNIT ONLY, LABOR ONLY) |
| 0063 |
| Steris |
| SE0710111 |
| LABOR CARE FOR RELIANCE 6500 (EXPANSION UNIT ONLY) |
| 0064 |
| Steris |
| SE0710111028 |
| 2 YRS LABOR CARE REL 6500 (EXPANSION UNIT ONLY) |
Service/ Parts and Labor
| 0065 |
| Steris |
| SE0710000028 |
| 2 YRS OF PREVENTIVE CARE REL 6500 (MAIN UNIT ONLY) |
| 0066 |
| Steris |
| SE0710000045 |
| 1ST YR PREV CARE FOR REL 6500 (MAIN UNIT ONLY) |
| 0067 |
| Steris |
| SE0710000048 |
| PREVENTIVE CARE FOR RELIANCE 6500 (MAIN UNIT ONLY) |
| 0068 |
| Steris |
| SE0710052 |
| TOTAL CARE CONNECT FOR REL 6500 (MAIN UNIT ONLY) |
| 0069 |
| Steris |
| SE0710053 |
| 2 YRS TOTAL CARE CONNECT REL 6500 (MAIN UNIT ONLY) |
| 0070 |
| Steris |
| SE0710100028 |
| 2 YRS OF PREV CARE REL 6500 (EXPANSION UNIT ONLY) |
| 0071 |
| Steris |
| SE0710100045 |
| 1ST YR PREV CARE REL 6500 (EXPANSION UNIT ONLY) |
| 0072 |
| Steris |
| SE0710100048 |
| PREVENTIVE CARE FOR REL 6500 (EXPANSION UNIT ONLY) |
| 0073 |
| Steris |
| SE0710152 |
| TOTAL CARE CONNECT FOR REL 6500 (EXPANSION UNIT ONLY) |
| 0074 |
| Steris |
| SE0710153 |
| 2 YRS TCC RELIANCE 6500 (EXPANSION UNIT ONLY) |
The Department of Veterans Affairs (VA) is seeking vendors who can provide Steris® Endodry Endoscope Drying and Storage Cabinets - Vertical or equal as listed above which meet all the salient characteristics listed below. Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor’s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor’s pricing volume with a quantity of zero.
CLIN’s 0001 - 0074 apply to the following SC’s
| SC# |
| SALIENT CHARACTERISTICS |
| METHOD OF EVALUATION |
| APPLICABLE CLINS |
| LOCATION IN TECHNICAL |
LITERATURE WHERE SC
IS MET
SC 1
The Endoscope Drying and Storage Cabinet shall be a stand-alone cabinet equipped with channel purging and vertical storage.
Literature Review 0001 - 0004
SC 2
The Endoscope Drying and Storage Cabinet shall use HEPA-filtered air, both within the cabinet and for purging of endoscope channels in alignment with meeting ANSI/AAMI ST91:2021 standards.
0001 - 0004
SC 3
The Endoscope Drying and Storage Cabinet shall have the ability to expand scope capacity with an add on expansion unit.
0001 - 0004
SC 4
The Endoscope Drying and Storage Cabinet shall be equipped with retractable endoscope storage panels.
0005 - 00010
SC 5
All proposed connectors and accessories must be compatible with the Drying and Storage Cabinet.
0005 - 0057
| SC 6 |
| The Endoscope Drying and Storage Cabinet shall be equipped with an endoscope hang time tracking system. |
0001 - 0004
| SC 7 |
| Minimum one-year warranty for all CLIN items. |
0001 - 0004
3. INSTALLATION
The ordering facility and the vendor/manufacturer will schedule any offered installation, deinstallation, and disposal. When there is a need to procure these CLINs, the ordering facility will communicate with the vendor on the schedule and delivery times upon receipt of goods based on facility needs. In some instances when installation is not required, the contractor should note if there are instructions for use.
4. TRAINING
The ordering facility and the vendor/manufacturer will schedule any offered training if available. If available, the training mode of delivery and training schedule are based on facility needs.
5. MAINTENANCE, REPAIRS AND REPLACEMENT
Instructions and procedures will be provided by the vendor specifically to the warranty, maintenance, repairs, and replacement of product and services. At minimum, vendor will propose manufacturer warranty period that may include response time, parts, associated maintenance services and consumables.
6. PRODUCT REFRESH
Product refresh is when a current CLIN is no longer being manufactured due to obsolescence and the product item is being replaced with a newer, and more often, a superior version of the same item. The current CLIN product will be revised to reflect the refreshed product information, manufacturer’s part number, IDIQ price (inclusive of Service Level Agreement (SLA) fee), etc.
The Government reserves the right to not accept the products offered under product refresh. The contractor will be notified in writing if a product refresh is not accepted. All products offered shall be provided with the warranty that is agreed upon for this contract.
The contractor agrees to ensure that all upgraded improved/replaced products meet American with Disabilities Act (ADA) and Health Information Portability and Accountability Act (HIPAA) Federal requirements.
The contractor shall provide the COR and CO the following information for product refresh:
(1) A list of specific awarded item(s) being refreshed in the Price/Cost Schedule (to include commercial pricing, discount offered, and IDIQ price (inclusive of SLA fee)).
(2) Product literature for the item(s) refreshed.
(3) A detailed description of the differences or benefits of refreshed as compared to the item(s) being discontinued or added.
(4) Proper identification of any product requirements and/or procedures related to those product(s) proposed to be refreshed or upgraded.
(5) FDA approval, if applicable
(6) Provide historical sales to VA by item(s), if applicable
(7) Copy of Commercial Warranty.
The request shall be submitted to the COR, copy to the Contract Specialist and Contract Officer, for review and recommendation of approval to be submitted to the CO. The CO shall prepare a bilateral modification for execution.
7. PRODUCT REMOVAL OR RECALL
For any product awarded under this contract removed or recalled by the manufacturer due to defects in the product or potential dangers to patients, or if any required removal or recall is suggested or mandated by a regulatory or official agency, the manufacturer agrees to take the following steps immediately:
Notify the Contracting Officer (CO) at the Strategic Acquisition Center in writing, by the most expeditious manner possible.
Provide copies of the notification to CO, Contracting Specialist, Contracting Officer Representative, and Manager at Product Recall Office, all Agencies and VA Facilities who purchased the product, which include, but not be limited to the following:
(1) Complete item description and/or identification, order numbers from customers and the contract number assigned because of an issuance on the solicitation;
(2) Reasons for modifications, removal or recall; and
(3) Necessary instructions for return for credit, replacement or corrective action.
A copy of the notification will be provided to:
Manager, Product Recall Office National Center for Patient Safety Veterans Health Administration 24 Frank Lloyd Wright Drive, Lobby M Ann Arbor, MI 48106
The following attachments are incorporated by reference. All criteria outlined in the attachments are applicable to this Combined Synopsis/Solicitation Notice.
See attached document: ATTACHMENT A - PRICE COST SCHEDULE NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT B - CONTRACT ADMINISTRATION -NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT C - Contract Clauses NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT E - REPORTING TOOL - NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT F - PAST PERFORMANCE REFERENCE - NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT G - PAST PERFORMANCE QUESTIONAIRE - NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT A - PRICE COST SCHEDULE NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT B - CONTRACT ADMINISTRATION -NX EQ Endoscope Cabinets-Vertical-Resolved.
See attached document: ATTACHMENT C - Contract Clauses NX EQ Endoscope Cabinets-Vertical .
See attached document: ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ Endoscope Cabinets-Vertical .
See attached document: ATTACHMENT E - REPORTING TOOL - NX EQ Endoscope Cabinets-Vertical.
See attached document: ATTACHMENT F - PAST PERFORMANCE REFERENCE - NX EQ Endoscope Cabinets-Vertical .
See attached document: ATTACHMENT G - PAST PERFORMANCE QUESTIONAIRE - NX EQ Endoscope Cabinets-Vertical.
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Page 1 of
Combined Synopsis/Solicitation Notice
File details come from the government source that posted it. Updated .