P01 - 653-107-Roseburg B11_-Seismic Retrofit IFC Submittal-Drawings.pdf
PDF 35 MB Posted
- Solicitation number
- 36C10F26R0082
About this file
This document is a comprehensive Invitation for Bid (IFB) submittal package containing architectural and structural design drawings for the Seismic Retrofit and Renovate Building 11 (Laundry) project at the Roseburg VA Medical Center in Oregon (Project #653-107). The solicitation, numbered 36C10F26R0082, seeks a single firm-fixed-price contract for complete seismic retrofitting of the existing laundry building, with work to be performed in accordance with the provided plans, specifications, and all applicable local, state, federal, and VA codes. The project is open to 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) competition, though any legally organized firm may submit a proposal.
The scope of work encompasses seismic bracing of existing exterior clay tile partition walls, removal and reinstallation of exposed conduit and wall-mounted equipment, replacement of suspended acoustical ceiling and grid in toilet rooms, reconfiguration of existing toilet and locker rooms with new fixtures and finishes, installation of new exhaust fans, HVAC unit replacement, addition of security chainlink fencing around HVAC units, and comprehensive structural upgrades including light-gauge strongback walls, concrete overlays, and intermediate moment frames. The work is divided into three phases: Phase 1 (Preparations), Phase 2 (Selective demolition and construction on wash/dirty side), and Phase 3 (Selective demolition and construction on dry/clean side). Critical requirements include maintaining operational laundry functions by phasing work to allow only one side (wash or dry) to be shut down at a time, coordinating with existing equipment under warranty from 2016 replacements, providing temporary heating/cooling during HVAC replacement, managing hazardous materials remediation, and obtaining pre-approval for hot work permits and infection control risk assessments. The building will remain occupied during normal business hours (08:00 AM - 04:30 PM), and contractor-coordinated downtime for critical work will occur during overnight hours or weekends as pre-approved by the Contracting Officer's Representative (COR). Proposals must be submitted electronically in Adobe PDF format via email to 003C4C.acquisitions@va.gov.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C10F26R0082_2.docx | DOCX document | |
| 36C10F26R0082 0003.pdf | ||
| RFI B11 Seismic Retrofit and Renovate Laundry 36C10F26R0082.pdf | ||
| 36C10F26R0082 0002_1.docx | DOCX document | |
| Site Visit Sign-In Sheet B11.pdf | ||
| 36C10F26R0082 0001 B11.pdf | ||
| P01 -653-107-Roseburg B11_-Seismic Retrofit IFC Submittal-Vol 2-Specs.pdf | ||
| P01 - 82245137 Roseburg VAMC Building 11 Seismic Upgrade GeoReport - signed.pdf | ||
| S02_ATTACHMENT 1_Key Personnel Resume Form.docx | DOCX document | |
| 36C10F26R0082_1.docx | DOCX document | |
| S02_ATTACHMENT 2_PPQ.docx | DOCX document | |
| S02_ATTACHMENT 3_Proposal Data Sheet.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. SEISMICALLY BRACE EXISTING EXTERIOR
CLAY TILE PARTITION WALLS.
2. ALL EXPOSED CONDUIT, PIPING, AND OTHER
WALL MOUNTED EQUIPMENT WILL NEED TO BE
REMOVED, SALVAGED, AND REINSTALLED ON
THE SIESMICALLY IMPROVED WALLS.
3. REMOVE AND REPLACE EXISTING
SUSPENDED ACOUSTICAL PANEL CEILING AND
GRID IN TOILET ROOMS
4. REMOVE EXISTING DOORS AND FRAMES IN
EXISTING DEMO'D WALLS AND REPLACE AS
REQUIRED.
5. REMOVE, SALVAGE AND REINSTALL
OVERHEAD GARAGE DOORS.
6. EXISTING TOILET AND LOCKER ROOMS TO BE
COMPLETELY RECONFIGURED AND RECEIVE
NEW FIXTURES, EQUIPMENT AND FINISHES.
7. PROVIDE NEW EXHAUST FANS IN EXISTING
TOILET AND LOCKER ROOMS.
8. REPLACE ACU-1
9. ADD SECURITY CHAINLINK FENCING AROUND
HVAC UNITS IN THE BACK OF THE BUILDING.
VA HEALTHCARE SYSTEM
ROSEBURG, OR
ROSEBURG, OR
X
Room Name
Ref
A101
A7.01 1
A7.024
ROOM NAME AND NUMBER
SECTION CALLOUT
MARK
DETAIL CALLOUT MARK
EXTERIOR OR INTERIOR
ELEVATION CALLOUT MARK
INTERIOR ELEVATION
CALLOUT MARK
DOOR TAG
MATERIAL FINISH TAG
SEE SCHEDULE SHEET AI104
WALL TYPE TAG
SEE SCHEDULE SHEET A-601
A1 A-101
PL1
SIGNAGE TAG
SEE SCHEDULE SHEET AW600
SN-X
1i EQUIPMENT TAG
SEE SCHEDULE SHEET A-604
NORTH ARROW
WINDOW / RELITE TAG
SEE SCHEDULE SHEET A-604
1t
PRINCIPAL IN CHARGE: Blue Trident, LLC Emmanuel (Manny) Bautista, PE*, F.SAME-----------(206) 972-0645 PRJT MGR/ STRUCT. ENG. Blue Trident, LLC Brian Moll, PE, SE ----------------------------------------(206) 351-2217 ARCHITECT Blue Trident, LLC Lauri Strauss, AIA, LEED AP BD&C---------------------(907) 317-5040 STRUCTURAL ENGINEER: Reid Middleton Brian Matsumoto----------------------------------------------(425) 741-3800 MECHANICAL ENGINEER: Notkin P2S, inc Peter Eberle, PE----------------------------------------------(206) 267-6940 ELECTRICAL ENGINEER: SAZAN Group Chris Larson, PE----------------------------------------------(503) 416-2078 FIRE PROTECTION ENGINEER: SAZAN Group Philip Roach, PE----------------------------------------------(503) 416-2400 HAZARDOUS MATERIALS MedTox NW. Jon Havelok----------------------------------------------------(253) 351-0677 COST ESTIMATOR: ProDims, PLLC Dennis Teschlog ----------------------------------------------(714) 651-6696 GEOTECHNICAL ENGINEER Terracon Ryan Houser, PE ---------------------------------------------(503) 416-2078
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1.
2.
a.
3.
4.
a.
b.
a.
a.
1.
2.
3.
a.
b.
a.
a.
b.
c.
PHASE 1 – PREPARATIONS
THIS BUILDING IS THE MAIN LAUNDRY BUILDING FOR THE VA CAMPUS. THERE ARE TYPICALLY BETWEEN 9-11 EMPLOYEES WORKING IN THE BUILDING DURING NORMAL BUSINESS HOURS. ALL THE LAUNDRY EQUIPMENT WAS REPLACED WITH A MAJOR PROJECT IN 2016. SOME OF THE EQUIPMENT IS STILL UNDER WARRANTY AND THEREFORE MUST BE TREATED WITH EXTREME CARE SO THOSE WARRANTIES ARE NOT VOIDED. SOME OF THE EQUIPMENT HAS SENSITIVE ELECTRONICS THAT WILL NEED TO BE PROTECTED FROM DUST AND EXTREME TEMPERATURES DURING CONSTRUCTION OPERATIONS. THIS MAY REQUIRE PROVIDING TEMPORARY HEATING AND/OR COOLING WHILE THE HVAC UNIT IS BEING REPLACED. WHILE THE LAUNDRY OPERATIONS MUST BE KEPT FUNCTIONAL, SOME DOWN TIME AND OUTAGES CAN BE TOLERATED. THE VA HAS INDICATED THEY CAN SEND OUT EITHER THE WASH FUNCTION OR THE DRY FUNCTION TO A NEARBY FACILITY TO ACCOMPLISH THIS WORK, BUT THERE IS NO OTHER LOCATION THAT CAN HANDLE THE FULL OPERATION. THEREFORE, THE PHASING INTENT IS TO ONLY SHUT DOWN ONE SIDE (WASH OR DRY) OF THE LAUNDRY AT A TIME, AND TO ONLY SHUT DOWN THE AREAS NECESSARY FOR THE SEISMIC MITIGATION. I.E, SHUTTING DOWN ONE OR TWO WASHING MACHINES, ALLOWING OTHERS TO CONTINUE TO FUNCTION. SAME WITH DRYERS, SHUT DOWN ONE OR TWO BUT KEEP OTHERS UP AND RUNNING. THIS WILL ALL BE COORDINATED WITH THE COR AND LAUNDRY
DIRECTOR.
CONTRACTOR SHALL FURNISH THE COR WITH A SCHEDULE OF PHASING DATES ON WHICH THE CONTRACTOR INTENDS TO ACCOMPLISH WORK IN EACH SPECIFIC AREA OF SITE, BUILDING OR PORTION THEREOF. ARRANGE SUCH DATES TO ENSURE ACCOMPLISHMENT OF THIS WORK IN SUCCESSIVE PHASES MUTUALLY AGREEABLE TO COR USING THE FOLLOWING PHASING
OUTLINE.
BUILDING WILL REMAIN OCCUPIED WHILE THE VA PERFORMS NORMAL BUSINESS OPERATIONS THROUGHOUT THE DURATION OF THIS PROJECT. CONTRACTOR IS RESPONSIBLE TO PERFORM ALL WORK SO THE NORMAL BUSINESS OPERATIONS CAN OCCUR. THE VA WILL WORK WITH THE GC TO PROVIDE SOME SHORT-TERM, TEMPORARY DOWN TIMES TO GET HVAC AND ELECTRICAL REPLACEMENTS ACCOMPLISHED. THESE TIMES WILL NEED TO BE PRE-APPROVED AND WILL LIKELY OCCUR IN OVERNIGHT HOURS
OR ON WEEKENDS.
NORMAL BUSINESS HOURS ARE 08:00AM – 04:30PM.
UPCOMING PHASED WORK SHALL BE AN AGENDA ITEM IN WEEKLY CONSTRUCTION PROGRESS MEETINGS.
CONTRACTOR SHALL COORDINATE SITE OFFICE AND MATERIAL LAYDOWN AREA WITH COR PRIOR TO MOBILIZATION.
CONTRACTOR SHALL COORDINATE MOVING OF EQUIPMENT WITH THE EQUIPMENT MANUFACTURER TO ACCOMPLISH THE SCOPE OF WORK. SOME EQUIPMENT MAY BE REQUIRED TO BE MOVED ONLY BY A CERTIFIED MANUFACTURER ’S REPRESENTATIVE, SO
WARRANTIES ARE NOT VOIDED.
THE CONTRACT DOCUMENTS FOR THIS PROJECT SHOW ONLY THE 2D PLAN VIEW OF THE EQUIPMENT.
THE VA WILL PROVIDE A SET OF RECORD DRAWINGS SHOWING THE EXISTING EQUIPMENT LOCATIONS, CONNECTIONS, AND
MANUFACTURES, FROM WHEN THE EQUIPMENT WAS REPLACED IN 2016.
SUBMIT MOVING WORK PLAN TO THE COR FOR APPROVAL.
COMPLETE AIR TESTING OF ALL SUPPLY, RETURN AND EXHAUST GRILLES TO DOCUMENT EXISTING CONDITIONS PRIOR TO WORK.
PROVIDE DRAWINGS OF BUILDING 11 CONSTRUCTION PHASES TO THE COR AND DESIGN TEAM FOR REVIEW.
PHASE 2 – SELECTIVE DEMOLITION (WASH = “DIRTY” SIDE) AND NEW CONSTRUCTION
CONTRACTOR SHALL COORDINATE IN ADVANCE WITH THE COR FOR THE REMOVAL AND RELOCATION OF EXISTING EQUIPMENT.
CONTRACTOR IS RESPONSIBLE TO PERFORM ALL WORK, SO THE FIRE AND LIFE SAFETY DEVICES REMAIN FUNCTIONAL.
IF A SHUTOFF IS REQUIRED, SUBMIT PLAN OF INTERMITTENT LIFE SAFETY MEASURES (ILSM) TO COR FOR REVIEW AND
APPROVAL.
CONTRACTOR IS RESPONSIBLE TO PERFORM ALL WORK TO ALLOW THE BUILDING NETWORK DEVICES TO REMAIN FUNCTIONAL.
PERMITS:
SUBMIT HOT WORK PERMITS TO THE COR FOR VA SAFETY OFFICE APPROVAL.
SUBMIT INFECTION CONTROL RISK ASSESSMENT TO VA FOR DETERMINATION OF SAFETY MEASURES REQUIRED TO BE
IMPLEMENTED DURING CONSTRUCTION.
5. PROVIDE DETAILED SEQUENCE OF WORK FOR THE DEMOLITION OF EXISTING AND INSTALLATION OF NEW STEAM COILS (HC-3 AND HC-5) SERVING WASH “DIRTY” SIDE OF THE BUILDING, INCLUDING ISOLATION OF STEAM AND CONDENSATE PIPING TO COILS AS NECESSARY, VERIFY EXISTING ISOLATION/SHUTOFF VALVES WORK PRIOR TO START OF DEMOLITION.
6. PROVIDE DRAWINGS SHOWING THE SEISMIC BRACING LOCATIONS OF EXISTING PIPING AND DUCTWORK.
7. PROVIDE A SEQUENCE OF WORK FOR THE REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL PANELS. THIS WORK WILL NEED TO BE PERFORMED IN THE EVENINGS OR WEEKENDS AS DETERMINED AND APPROVED BY THE COR. ELECTRICAL PANEL
REMOVALS WILL NEED TO HAPPEN SIMULTANEOUSLY.
8. INCLUDE COORDINATION FOR SHUT OFF, CAPPING AND/OR CONTINUATION OF UTILITY SERVICES AS REQUIRED.
PROVIDE DETAILED SEQUENCE OF DEMOLITION AND REMOVAL WORK TO ENSURE UNINTERRUPTED PROGRESS OF VA ON-
SITE OPERATIONS AND BUILDING OPERATIONS.
9. REFERENCE THE CONTRACT DRAWINGS AND SPECIFICATIONS FOR HAZARDOUS MATERIALS LOCATION AND MITIGATION
PROCEDURES IN THE CRAWL SPACE AND MAIN FLOOR.
10. PRIOR TO BUILDING INTERIOR SEISMIC UPGRADES, CONCRETE OVERLAY OR LIGHT GAUGE STUD STRONGBACKS, CAREFULLY REMOVE ALL ITEMS FASTENED TO OR MOUNTED ON EXISTING WALLS RECEIVING THE STRUCTURAL UPGRADES.
SOME OF THESE ITEMS MAY BE ALLOWED TO BE LEFT OR REINSTALLED IN THE STUD CAVITY OF THE STRONGBACK WALLS.
COORDINATE WITH THE ENGINEERS WHERE ITEMS ARE NOT CLEARLY SHOWN ON THE CONTRACT DOCUMENTS.
REINSTALL ALL FUNCTIONAL ITEMS SUCH AS CONDUITS, DUCTS, FIRE/LIFE SAFETY ITEMS, ETC. ON THE FACE OF NEW
CONCRETE WALLS.
b) SOME ITEMS MAY BE RELOCATED DUE TO NEW OR REPLACED MEP SYSTEMS.
PHASE 3 – SELECTIVE DEMOLITION (DRY = “CLEAN” SIDE) AND NEW CONSTRUCTION
CONTRACTOR SHALL COORDINATE IN ADVANCE WITH THE COR FOR THE REMOVAL AND RELOCATION OF EXISTING EQUIPMENT.
CONTRACTOR IS RESPONSIBLE TO PERFORM ALL WORK, SO THE FIRE AND LIFE SAFETY DEVICES REMAIN FUNCTIONAL.
IF A SHUTOFF IS REQUIRED, SUBMIT PLAN OF INTERMITTENT LIFE SAFETY MEASURES (ILSM) TO COR FOR REVIEW AND APPROVAL.
3. CONTRACTOR IS RESPONSIBLE TO PERFORM ALL WORK TO ALLOW THE BUILDING NETWORK DEVICES REMAIN FUNCTIONAL.
4. PERMITS:
SUBMIT HOT WORK PERMITS TO THE COR FOR VA SAFETY OFFICE APPROVAL.
SUBMIT INFECTION CONTROL RISK ASSESSMENT TO VA FOR DETERMINATION OF SAFETY MEASURES REQUIRED TO BE
IMPLEMENTED DURING CONSTRUCTION.
5. PROVIDE DETAILED SEQUENCE OF WORK FOR THE DEMOLITION OF THE EXISTING AND INSTALLATION OF NEW STEAM COILS (HC-1, HC-2, AND HC-4) SERVING THE DRY “CLEAN” SIDE OF THE BUILDING, INCLUDING ISOLATION OF STEAM AND CONDENSATE PIPING TO COILS AS NECESSARY, VERIFY EXISTING ISOLATION/SHUTOFF VALVES WORK PRIOR TO START OF DEMOLITION.
6. PROVIDE DRAWINGS SHOWING THE SEISMIC BRACING LOCATIONS OF EXISTING PIPING, EQUIPMENT, AND DUCTWORK.
7. PROVIDE DETAILED SEQUENCE OF WORK FOR THE DEMOLITION OF THE EXISTING AIR HANDLER (ACU-1), INSTALLATION OF NEW AIR HANDLER (AHU-11), AND EXTERIOR DUCTWORK MODIFICATIONS TO ACCOMMODATE NEW AIR HANDLER.
8. PROVIDE A SEQUENCE OF WORK FOR THE REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL PANELS. THIS WORK WILL NEED TO BE PERFORMED IN THE EVENINGS OR WEEKENDS. THIS WORK WILL NEED TO HAPPEN SIMULTANEOUSLY.
9. INCLUDE COORDINATION FOR SHUT OFF, CAPPING AND/OR CONTINUATION OF UTILITY SERVICES AS REQUIRED.
PROVIDE DETAILED SEQUENCE OF DEMOLITION AND REMOVAL WORK TO ENSURE UNINTERRUPTED PROGRESS OF VA ON-SITE
OPERATIONS AND BUILDING OPERATIONS.
10. REFERENCE THE CONTRACT DRAWINGS AND SPECIFICATIONS FOR HAZARDOUS MATERIALS LOCATION AND MITIGATION
PROCEDURES IN THE CRAWL SPACE AND MAIN FLOOR.
11. PRIOR TO BUILDING INTERIOR SEISMIC UPGRADES, CONCRETE OVERLAY OR LIGHT GAUGE STUD STRONGBACKS, CAREFULLY REMOVE ALL ITEMS FASTENED TO OR MOUNTED ON EXISTING WALLS RECEIVING THE STRUCTURAL UPGRADES.
SOME OF THESE ITEMS MAY BE ALLOWED TO BE LEFT OR REINSTALLED IN THE STUD CAVITY OF THE STRONGBACK WALLS.
COORDINATE WITH THE ENGINEERS WHERE ITEMS ARE NOT CLEARLY SHOWN ON THE CONTRACT DOCUMENTS.
REINSTALL ALL FUNCTIONAL ITEMS SUCH AS CONDUITS, DUCTS, FIRE/LIFE SAFETY ITEMS, ETC. ON THE FACE OF NEW
CONCRETE WALLS.
SOME ITEMS MAY BE RELOCATED DUE TO NEW OR REPLACED MEP SYSTEMS.
1/ 2' 0'
1' 4'
4' 8'
8' 8'
4' 2'
2'
1/ 8' 0'
1/ 0'
1/ 4' 0'
1' 2'
1' 1/
2' 2'
1/ 2'
1' 0'
3' 0'
1'
3/ 8' 0'
1'
2' 4'
1/
2' 0'
2'
1/ 2'
1' 3'
6' 0'
1/
4" 1/
2"
3/ 0'
8'
4' 4'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C :\U se rs
\la ur i\O ne
D riv e
- d es ig n2 la st .c om \d
2L -P ro je ct s\
-0
R os eb ur g
Bl dg s
-1 3-
\0
4- D
ES
IG
N \B
IM
M
O D
EL
A
N D
L
IN
KS
\R
O
SE
BU
R
G
AR
C H
.rv t
4/ 3/
:5
2:
P M
GI001
B11 COVER
BLUE TRIDENT, LLC
900 Winslow Way E, Suite 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
SEISMIC RETROFIT AND
RENOVATE BUILDINGS 11,13 & 16
VA Roseburg Healthcare System
653-107 director
4/3/2026 MR LMS
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
SEISMIC RETROFIT AND RENOVATE BUILDINGS 11,13 & 16
DRAWING INDEX
SCOPE OF WORK
ABBREVIATIONS
RENDERING
VICINITY MAP PHASINGSYMBOLS
VA Roseburg Healthcare System
BUILDING 11
Project Number 653-107
PROJECT TEAM
A
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANNODIZED
APPROX APPROXIMATE
B
BD BOARD
BF BRACE FRAME
BLDG BUILDING
BLKG BLOCKING
BOD BOTTOM OF DECK
BOT BOTTOM
C
CAB CABINET(S)
CJ CONROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
COL COLUMN
CONC CONCRETE
COR CONTRACTING OFFICERS
REPRESENTATIVE
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTB CERAMIC TILE COVE BASE
D
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIFF DIFFERENCE
DIM DIMENSION
DISP DISPENSER / DISPOSAL
DN DOWN
DWG DRAWING(S)
E
EA EACH
ELEC ELECTRIC
EQ EQUAL
EQUIP EQUIPMENT
EXG EXISTING
EXP JT EXPANSION JOINT
EXT EXTERIOR
F
FACP FIRE ALARM CONTRL PANEL
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FIN FINISH
FLR FLOOR
FOC FACE OF CABINET
FOF FACE OF FINISH
FOS FACE OF STUD
FOW FACE OF WALL
G
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GEN GENERAL
GLU-LAM GLUE LAM BEAM
GWB GYPSUM WALL BOARD
GYP GUPSUM
H
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HVAC HEATING VENTILATION AIR
CONDITIONING
I
IBC INTERNATIONAL BUILDING
CODE
ID INTERIOR DESIGN
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
J
JAN JANITOR
JT JOINT
K
KIT KITCHEN
L
LAM LAMINATED
LAV LAVATORY
LF LINEAR FEEET
M
MATL MATERIAL
MAX MAXIMUM
MBL MARBLE
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MFG MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MS METAL STUD
MTD MOUNTED
MTL METAL
N
NA NOT APPLICABLE
NAP NAPKIN
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
ORIG ORIGINAL
P
PAF POWER ACTIVATED
FASTENERS
PLAM PLASTIC LAMINATE
PLWD PLYWOOD
PREFAB PRE FABRICATED
PREFIN PRE FINISHED
PT PAINT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
Q
QT QUARRY TILE
R
RAD RADIUS
RB RUBBER
RCP REFLECETED CEILING PLAN
REF REFERENCE
REINF REINFORCING
REQD REQUIRED
RESIL RESILIENT
S
SAN SANITARY
SCHED SCHEDULE
SD SOAP DISPENSER
SF SQUARE FOOT
SHT SHEET
SHWR SHOWER
SIM SIMILAR
SND SANITARY NAPKIN DISPOSAL
SS SOLID SURFACE
SST STAINLESS STEEL
STD STANDARD
STL STEEL
STO STORAGE
STS SELF TAPPING SCREW
T
TB TOWEL BAR
TEMP TEMPORARY
THK THICK
THRU THROUGH
TLT TOILET
TO TOP OF
TPD TOILET PAPER DISPENSER
TPTN TOILET PARTITION
TR TRASH RECEPTACLE
TYP TYPICAL
TZO TERRAZZO
U
UC UNDER COUNTER / UNDER
CABINET
UNFIN UNFINISHED
UON UNLESS OTHERWISE NOTED
V
VAR VARIES
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
W
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WR WATER RESISTANT
WWF WELDED WIRE FABRIC
B11
PROJECT
LOCATION
GI001 B11 COVER
GI011 CODE PLAN
HM-003A HAZARDOUS MATERIALS REMEDIATION - CRAWL SPACE
HM-003 HAZARDOUS MATERIALS REMEDIATION - 1ST FLOOR
S-001 GENERAL STRUCTURAL NOTES
S-100 FOUNDATION PLAN
S-101 FLOOR FRAMING PLAN
S-102 ROOF FRAMING PLAN
S-200 SHEAR WALL ELEVATIONS
S-201 SHEAR WALL ELEVATIONS
S-202 SHEAR WALL ELEVATIONS
S-203 SHEAR WALL ELEVATIONS
S-501 CONCRETE DETAILS
S-502 CONCRETE DETAILS
S-511 MASONRY DETAILS
S-512 MASONRY DETAILS
S-521 STEEL DETAILS
S-522 STEEL DETAILS
S-523 STEEL DETAILS
AD111 FIRST FLOOR DEMOLITION PLAN
A-111 B11 FIRST FLOOR PLAN
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-401 ENLARGED TOILET ROOMS
A-601 SCHEDULES AND DETAILS
AC111 REFLECTED CEILING PLAN AND SIGNAGE
FX000 B11 FIRE PROTECTION GENERAL NOTES AND LEGEND
FD111 B11 FIRE PROTECTION DEMOLITION - FIRST FLOOR PLAN
FX111 B11 FIRE PROTECTION - FIRST FLOOR PLAN
FX611 B11 FIRE PROTECTION DIAGRAMS
M-001 GENERAL NOTES LEGEND, ABBREVIATIONS, AND INDEX
MD-102 CRAWL SPACE PIPING DEMO PLAN
MD-111 FIRST FLOOR PIPING DEMO PLAN
MD-400 MECHANICAL ENLARGED DEMO PLANS
MD-401 MECHANICAL ENLARGED DEMO PLANS
M-102 CRAWL SPACE PIPING PLAN
M-111 FIRST FLOOR PLAN
M-112 FIRST FLOOR PIPING PLAN
M-211 ROOF PLAN
M-400 MECHANICAL ENLARGED PLANS
M-401 MECHANICAL ENLARGED PLANS
M-501 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-801 MECHANICAL CONTROLS
EG001 B11 GENERAL NOTES, ABBREV. AND SHEET INDEX
ED111 B11 ELECTRICAL DEMOLITION - FIRST FLOOR PLAN
EL111 B11 ELECTRICAL LIGHTING - FIRST FLOOR PLAN
EP111 B11 ELECTRICAL POWER - FIRST FLOOR PLAN
EL601 B11 ELECTRICAL LIGHTING SCHEDULE
EP621 B11 ELECTRICAL ONE-LINE DIAGRAM
Revisions: Date:
R
EF
FD FD
FD FD
FRONT
CHEM
PUMP
CHEM
PUMP
CHEM
PUMP
REMOTE
STATUS
MILDATAENERGY
MONITOR
X Y Y
X
X Y Y
X
FLATWORK RAIL
FLATWORK RAIL
DRYER RAIL
BLANKET RAIL
FLATWORK RAIL
EM
PTY SLIN
G
PU
LL-U
P
VAC
CAB
VAC
CAB
VAC
CAB
VA
LB
IA
VB
VA
LB
IA
V B
RIGIDLOK
4"
RIGIDLOK
2"
RIGIDLOK
2"
45O P E N
CLOSE
PUSHTO OPERATE
VALBIA - VB030
45OP
EN
CLOSE
PUSH
TO OPERATE
VALBIA - VB030
RIGIDLOK
2"
RIGIDLOK
2"
R
IG
ID
LO
K 2"
PU
M
P # 16 M
O
TO
R H p 3 R
PM
EN
C
L. TEFC
FR
AM
E 182JM
RIGIDLOK
2"
B A
LL VA
LVE
N
IB
C O 2"
RIGIDLOK
2"
RIGIDLOK
2"
RIGIDLOK
2"
R
IG
ID
LO
K 2" union_ 2_ inch
5/ 8" A
DJ
U
ST
IN
G
Y-STRAINER, STD, 1.5"
HO
FF
MA
N
TF
5X -8
UP
BUILDING TYPE = LAUNDRY
CODE: NFPA 13, 70, 72, 90A, 101 (INCL CH 43.10)
IEBC 2021
THE BUIILDING IS PROVIDED THROUGHOUT WITH AN APPROVED
AUTOMATIC FIRE SPRINKLER SYSTEM.
USE AND OCCUPANCY (SAME AS EXISTING- NO CHANGE IN OCCUPANCY)
MODERATE HAZARD FACTORY INDUSTRIAL OCCUPANCY
SPECIAL-PURPOSE INDUSTRIAL OCCUPANCY: 40.1.2.1.2 (2)
(OCC TYPE F-1 FROM IBC)
OCCUPANT LOAD FACTOR 7.3.1.2
MP: THE OCCUPANT LOAD IS THE MAXIMUM PROBABLE NUMBER OF
OCCUPANTS PRESENT AT ANY TIME.
SPACE OCC AREA S.F./ OCC NO. OF OCC.
FIRST FLOOR 10,156 MP 11
TOTAL BUILDING OCCUPANT LOAD 11 OCCUPANTS
INCIDENTAL USE AREAS WITHIN PROJECT SCOPE:
STORAGE ROOMS >100 S.F. - SMOKE SEPARATION PROVIDED
CONSTRUCTION TYPE
TYPE V-000 – NON-COMBUSTIBLE - FULLY SPRINKLERED
BUILDING AREA HEIGHT AND AREA IS NOT CHANGING - LIMITATIONS:
GENERAL BUILDING HEIGHTS AND AREAS
BASIC ALLOWABLE AREA (TABLE 503; F-1 SPRNKLD) 52,000 S.F.
BASIC ALLOWABLE HEIGHT 3 STORIES – 60’-0”
ACTUAL AREA AND HEIGHT
AREA ACTUAL 10,156 S.F.
HEIGHT ACTUAL 1 STORY - 32'-9 1/2" +/-
RATED ASSEMBLIES WITHIN THE PROJECT AREA REQUIRED:
NONE (NFPA 101, 7.1.3.1)
(NFPA 101, 7.1.3.1 - CORRIDORS ARE NOT REQUIRED TO BE RATED IN AN
EXISTING BUILDING WHERE THE OCCUPANCY CLASS IS NOT CHANGING.)
NFPA CH. 40 - INDUSTRIAL OCCUPANCIES
MEANS OF EGRESS NFPA 101, 40.2.2
MINIMUM DOOR LEAF: NFPA 101, 7.2.1.2.3.
32" - MINIMUM DOOR LEAF
28" - MIN DOOR LEAF IN EXISTING BUILDINGS
WIDTH PROVIDED = 36"
CAPACITY OF MEANS OF EGRESS: NFPA 101, 40.2.3
OCC LOAD IS DETERMINED AS THE MAXIMUM PROBABLE
POPULATION OF THE SPACE - SIZE OF EXITS COMPLY
MINIMUM NUMBER OF EXITS: NFPA 101, 40.2.4.1.1
NOT LESS THAN 2 EXITS FROM EVERY STORY:
NUMBER OF EXITS PROVIDED = FIRST FLOOR: 4
COMMON PATH OF TRAVEL DISTANCE NFPA 101, TABLE 40.2.5.1: 100' MAX
FIRST FLOOR: 99' MAX TRAVEL DIST TO ALL EXITS
MAXIMUM TRAVEL DISTANCE MEASURED: NFPA 101, 40.2.6
400' MAX ALLOWED IN INDUSTRIAL OCC W/ FIRE SPRINKLER
FIRST FLOOR: 99' MAX
PROTECTION OF VERTICAL OPENINGS NFPA 101, 40.3.1 - N/A
PORTABLE FIRE EXTINGUISHERS: NFPA 10, 6.2.1.2.2.
ARE PROVIDED IN EACH SPACE WITH LESS THAN 75' TRAVEL DISTANCE TO
EACH.
SMOKE PARTITION
REFERENCE NFPA 8.4
1-HR FIRE RESISTANT
RATED BARRIER
2-HR FIRE RESISTANT
RATED BARRIER
HORIZONTAL SMOKE
BARRIER CEILING
ASSEMBLY
HORIZONTAL 1-HR FIRE-
RESISTANT RATED
ASSEMBLY (ABOVE)
LIFE/SAFETY LEGEND
BUILDING EXIT
EXIT ROUTE
FEC (NEW)
F4 A-301
E2 A-301
E6 A-301
F2 A-301
B4 A-301
B
7 8
C
9 10 11 12 13 14 15
D
E
F
A
H
J
G
DRYING
110a
DRYING
SHIPPING
e113
CART MAKE UP
e112
HALL
e104
HALL
e104b
LCKR W
111A
TOILET
TOILET
LCKR M
109A
BREAK ROOM
e108
MAINTENANCE
e107STORAGE e106
COMP
e105
WASHING
TANK ROOM
e100
HALL
e104a
WASHING
DOCK
101a
SHWR M
109B
SHWR W
111B e104b e105a e100b e100a e101a e110a e113b e106a e107a e108a e104a e113a
109a 111a109 111
109b 111b
1"
- (E
0"
- (E
6"
- (E
6"
- (E
116' - 0" +/- (E)
WASH ROOM
CART WASH
e102
11' - 8" +/- (E)12' - 0" +/- (E) e101b e103c e103a e103b
5' - 0" +/- (E)10' - 6" +/- (E)5' - 0" +/- (E)10' - 9" +/- (E)5' - 0" +/- (E)5' - 0" +/- (E)5' - 0" +/- (E)12' - 0" +/- (E)5' - 0" +/- (E)
E3
E3
E3
E3
E1E1
E3
E1
7'
- 6
E)
4' - 8" +/- (E)
110b
101b
E3
12' - 0" +/- (E)
15' - 4" +/- (E) 14' - 3" +/- (E) 14' - 3" +/- (E)14' - 3" +/- (E)14' - 3" +/- (E)14' - 3" +/- (E)14' - 3" +/- (E) 15' - 4" +/- (E)
0"
- (E
2"
- (E
0"
- (E
7'
- 1
1"
- (E )4'
- 1
E)
99'
66'
72'
75' 88'
53' 48'
1/ 2' 0'
1' 4'
4' 8'
8' 8'
4' 2'
2'
1/ 8' 0'
1/ 0'
1/ 4' 0'
1' 2'
1' 1/
2' 2'
1/ 2'
1' 0'
3' 0'
1'
3/ 8' 0'
1'
2' 4'
1/
2' 0'
2'
1/ 2'
1' 3'
6' 0'
1/
4" 1/
2"
3/ 0'
8'
4' 4'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C :\U se rs
\la ur i\O ne
D riv e
- d es ig n2 la st .c om \d
2L -P ro je ct s\
-0
R os eb ur g
Bl dg s
-1 3-
\0
4- D
ES
IG
N \B
IM
M
O D
EL
A
N D
L
IN
KS
\R
O
SE
BU
R
G
AR
C H
.rv t
4/ 3/
:5
2:
P M
GI011
CODE PLAN
BLUE TRIDENT, LLC
900 Winslow Way E, Suite 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
SEISMIC RETROFIT AND
RENOVATE BUILDINGS 11,13 & 16
VA Roseburg Healthcare System
653-107 director
4/3/2026 MR LMS
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
1/8" = 1'-0"F4 B11 FLOOR PLAN CODE PLAN
L
PL/
FOOT\FEET
ADDED TO
AND
ANGLE
AT
CENTERLINE
SOG REINF OR WWF
STEP IN SLAB\ROOF
DOWEL
OPENING
PLATE
" INCH\INCHES
MTL DK (SECTION)
W SECTION
METAL DECK W/CONC
TOPPING (PLAN)
METAL DECK (PLAN)
PERPENDICULAR
PARALLEL
MOMENT CONNECTION
A101
Ref
1Re f 1 Re f
Ref
WALL ELEVATION
DIAMETER
GENERAL:
1. THE FOLLOWING STRUCTURAL NOTES APPLY UNLESS NOTED OTHERWISE ON THE
STRUCTURAL DRAWINGS.
2. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
FINISHED STRUCTURE, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION.
THE CONTRACTOR WILL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE
STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT
BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT,
ETC.
3. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT
INCLUDE INSPECTION OF THE ABOVE ITEMS NOR WILL THE STRUCTURAL ENGINEER
BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES,
PROCEDURES OR SEQUENCES OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS
AND THE PROGRAMS INCIDENT THERETO.
4. THE STRUCTURAL NOTES SHALL BE USED ALONG WITH THE PROJECT
SPECIFICATIONS AND DRAWINGS. THE CONTRACTOR SHALL REQUEST
CLARIFICATION IMMEDIATELY UPON DISCOVERY AND BEFORE PROCEEDING,
WHERE A DIFFERENCE BETWEEN STRUCTURAL DRAWINGS, NOTES OR
SPECIFICATIONS OCCUR.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS
AND CONDITIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF
CONSTRUCTION. NOTIFY THE CONTRACTING OFFICER’S REPRESENTATIVE OF ANY
DISCREPANCIES OR INCONSISTENCIES IMMEDIATELY UPON DISCOVERY.
6. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS SHOWN ON DRAWINGS.
7. THE CONTRACTOR SHALL ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, SECURITY AND OTHER
ITEMS WITH APPROPRIATE TRADES, DRAWINGS, AND SUBCONTRACTORS PRIOR TO
CONSTRUCTION. NO PENETRATIONS THRU STRUCTURAL MEMBERS ALLOWED
UNLESS SHOWN ON STRUCTURAL DRAWINGS OR APPROVED BY STRUCTURAL
ENGINEER IN WRITING.
8. PLAN NOTES AND LOCATION SPECIFIC DETAILS ON DRAWINGS SHALL TAKE
PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.
9. TYPICAL DETAILS ARE NOT CUT ON PLANS, BUT APPLY UNLESS NOTED OTHERWISE.
WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR
WORK ON PROJECT.
10. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH
STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDUM.
11. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW
SHALL BEAR THE SEAL AND SIGNATURE OF A REGISTERED STRUCTURAL ENGINEER.
DESIGN CRITERIA:
1. GOVERNING/REFERENCE CODES:
2022 ASCE 7-22
2024 INTERNATIONAL BUILDING CODE
2022 AISC 16TH EDITION
VA H-18-8 (JULY 2023, REV NOV 2024)
ASCE 41-23
2. EXISTING BUILDING SEISMIC FORCE RESISTING SYSTEM: UNREINFORCED MASONRY
SHEAR WALLS AND FLEXIBLE DIAPHRAGMS (BUILDING 11 IS A 1-STORY, 14,051 GROSS
SQUARE FEET STRUCTURE. IT WAS ORIGINALLY BUILT IN 1933.). THE ORIGINAL
BUILDING DOES NOT CONFORM TO CURRENT BUILDING CODES. WITH ADDITIONS IN
1967,1976,1988 & 1998 AND HAS NOT UNDERGONE A SIGNIFICANT SEISMIC RETROFIT.
SEISMIC UPGRADES TO THE EXISTING STRUCTURE INCLUDE NEW STRONGBACKING OF
EXISTING BRICK EXTERIOR WALLS, NEW INTERMEDIATE MOMENT FRAMES IN 1976
NORTH SIDE ADDITION TO REDUCE SPAN OF EXISTING STEEL DECK DIAPHRAGM,
POSITIVE OUT OF PLANE AND IN-PLANE ANCHORAGE AT ROOF DIAPHRAGMS AND
INDEPENDENT SECONDARY SUPPORT AT ORIGINAL ROOF TRUSS BEARING.
FACILITY CRITICALITY DESIGNATION: ESSENTIAL
SITE-SPECIFIC SEISMIC RESPONSE SPECTRUM PER THE GEOTECHNICAL GROUND-
MOTION STUDY
RISK CATEGORY = III
SITE CLASS: C
Ss=1.02; S1 = 0.46 [ASCE 7] BSE-2N: Sxs = 1.16 ; Sx1 = 0.65 [ASCE 41] BSE-1N: Sxs = 0.78 ; Sx1 = 0.43[ASCE 41]
ANALYSIS PROCEDURE USED = LINEAR STATIC PROCEDURE
ASCE STRUCTURAL PERFORMANCE OBJECTIVES: IMMEDIATE OCCUPANCY AT
THE BSE-1N; LIFE SAFETY AT THE BSE-2N
ASCE 41 NON-STRUCTURAL PERFORMANCE OBJECTIVE = OPERATIONAL @
BSE-1N; HAZARDS REDUCED @ BSE-2N
3. LIVE LOADS:
A. ROOF = 25 PSF (SNOW)
B. OFFICE = (1ST FLOOR) = 80 PSF
C. MECH/ELEC = 150 PSF
D. LIGHT STORAGE = 125 PSF
E. CORRIDORS/LOBBIES/STAIRS = 100 PSF
F. LAUNDRY = 200 PSF
NOTE: STORAGE SPACES TO BE POSTED IN CONSPICUOUS LOCATION PER
IBC REQUIREMENTS
4. MECHANICAL & NON-STRUCTURAL ANCHORAGE:
A. DESIGN PER ASCE 7-22 CHAPTER 13, SEE SPECIFICATIONS
SECTION 13 05 41.
BOLTED CONNECTIONS:
1. BOLTED CONNECTIONS SHALL CONFORM TO AISC STANDARD BOLTED CONNECTIONS
WITH MAXIMUM NUMBER OF 3/4" DIAMETER A-325N BOLTS UNLESS DETAILED ON
DRAWINGS (SEE FRAMED BEAM CONNECTIONS, TABLES 10-1, 10-2, 10-3, 10-4 OR 10-9
OF AISC MANUAL OF STEEL CONSTRUCTION). HIGH STRENGTH BOLTS INCLUDING
NUTS AND WASHERS SHALL BE IN ACCORDANCE WITH ASTM SPECIFICATIONS AND
SHALL MINIMALLY MEET "SNUG TIGHT" CRITERIA AS DEFINED IN AISC “SPECIFICATION
FOR STRUCTURAL JOINTS …” UNO.
2. NO SLOTTED HOLES PERMITTED AT STEEL CONNECTIONS UNLESS APPROVED BY THE
CONTRACTING OFFICER’S REPRESENTATIVE.
3. WHERE BOLT HOLES IN STEEL MEMBERS ARE ENLARGED TO MORE THAN 1 /16"
DIAMETER OVERSIZE AT CONNECTION BOLTS (3/16" DIAMETER AT ANCHOR BOLTS),
PROVIDE 5/16" x 2-1/2" x 2-1/2" PLATE WASHERS WITH PROPER DIAMETER HOLE. PLATE
WASHERS SHALL BE WELDED TO STEEL MEMBER WITH 3/16" FILLET WELD ALL
AROUND.
4. THREADED RODS SHALL BE ASTM F1554 GR 55 W/ WELD SUPPLEMENT S-1, HEADED
STUDS & THREADED STUDS SHALL BE ASTM A29, WELDED DEFORMED BARS (WDB)
SHALL BE ASTM A496.
POST INSTALLED CONCRETE ANCHORS:
1. DRILLED AND EPOXY GROUTED CONCRETE ANCHORS AND ADHESIVE BAR ANCHORS,
SHALL BE EPOXY GROUTED WITH SIMPSON SET 3G, DEWALT ALT PURE 110+, OR HILTI
HIT-RE 500 V3 EPOXY ADHESIVE OR APPROVED EQUIVALENT UNO. DRILL OVERSIZE
HOLES, CLEAN, AND APPLY EPOXY PER MFR PRINTED INSTRUCTIONS. EPOXY SHALL
BE MIXED, APPLIED AND CURED IN STRICT ACCORDANCE WITH MFR PRINTED
INSTRUCTIONS. APPLY EPOXY ONLY TO CLEAN AND DRY CONCRETE AND PROVIDE
PROTECTION SO DOWELS ARE NOT DISTURBED DURING THE CURING PERIOD.
2. EXPANSION ANCHORS SHALL BE HILTI "KWIK BOLT TZ2", SIMPSON STRONG BOLT 2, OR
DEWALT "POWER SUD+ SD2" OR APPROVED EQUIVALENT. INSTALLATION SHALL BE IN
STRICT ACCORDANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS.
STRUCTURAL STEEL AND MISCELLANEOUS METALS:
1. DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS SHALL
BE IN ACCORDANCE WITH THE LATEST EDITION AISC SPECIFICATIONS, SECTION 5 AND
AWS D1 .1 SPECIFICATIONS AS MODIFIED BY THE CONTRACT SPECIFICATIONS.
2. ALL STRUCTURAL STEEL WIDE FLANGE BEAMS SHALL BE ASTM A-992.
GRADE 50 KSI.
3. MISCELLANEOUS STEEL SHALL BE ASTM A-36 (FY = 36 KSI).
4. ALL STEEL TUBE COLUMNS/BRACES SHALL BE ASTM A-500 GRADE B (FY = 46 KSI).
5. ALL STEEL PIPE COLUMNS/BRACES SHALL BE ASTM A-501 GRADE B. TYPE E
OR S (Fy = 35 KSI).
WELDED CONNECTIONS:
1. WHERE SIZE OF WELD IS NOT INDICATED, IT SHALL DEVELOP THE FULL STRENGTH OF
MEMBER AND CONNECTION.
2. NO SPLICES IN STEEL BEAMS OR COLUMNS MAY BE MADE OTHER THAN THOSE
DETAILED ON THE DRAWINGS UNLESS SHOWN ON SHOP DRAWINGS AND APPROVED
BY CONTRACTING OFFICERS REPRESENTATIVE.
3. ALL BEVEL GROOVE WELDS SHALL BE COMPLETE PENETRATION WELDS UNLESS
NOTED OTHERWISE.
4. ALL WELDING SHALL BE DONE BY CERTIFIED WELDERS - SEE SPECS.
CONCRETE:
1. CONCRETE FOR THE PROJECT SHALL ATTAIN A MINIMUM COMPRESSIVE
STRENGTH fc' AT 28 DAYS WITH A MINIMUM CEMENT QUANTITY PER
SPECIFICATION.
A. SLAB-ON-GRADE/FOUNDATIONS fc' = 4000 PSI B. CONCRETE OVERLAY SHEAR WALLS fc' = 4,000 PSI C. GROUT UNDER COLUMN BASE PLATES SHALL HAVE fc' = 6000 PSI
2. ALL REINFORCING STEEL FOR THE PROJECT SHALL BE DEFORMED BARS AND
SHALL CONFORM TO THE FOLLOWING ASTM STANDARD DESIGNATIONS.
A. #4 BARS AND LARGER IN CONCRETE AND MASONRY - A-615, GRADE 60 KSI
B. ANY REINFORCING TO BE WELDED - A-706, GRADE 60 KSI
C. VERTICAL REINFORCEMENT IN SHEAR WALLS AND COLUMNS/PILASTERS -
A706 GRADE 60 LOW ALLOY
3. REINFORCEMENT LAPS CONCRETE:
A. VERTICAL BARS - CLASS B
B. HORIZONTAL BARS - CLASS B (2'-0" MINIMUM)
4. THE FOLLOWING MINIMUM COVER SHALL BE PROVIDED FOR REINFORCEMENT
PLACED IN CONCRETE (UNLESS NOTED OTHERWISE):
A. CONCRETE WALLS EXPOSED TO EARTH OR WEATHER - 2"
B. CONCRETE NOT EXPOSED TO EARTH OR WEATHER - 1 1/2" [BEAMS/COLS]
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER - 1" [SLABS/WALLS]
D. CONCRETE CAST AGAINST EARTH - 3"
5. GEOTECHNICAL:
SOIL BEARING SURFACES AND FILL SHALL BE PREPARED IN ACCORDANCE WITH
THE GEOTECHNICAL REPORT AND INSPECTED BY THE GEOTECHNICAL ENGINEER
[OR AN APPROVED TESTING AGENCY].
GEOTECHNICAL REPORT REFERENCE: TERRACON CONSULTANTS INC., REPORT
#82245137, DATED FEBRUARY 25, 2025
FOOTINGS SHALL BE FOUNDED AT LEAST 18” BELOW LOWEST ADJACENT
EXTERIOR FINISHED GRADE. OVEREXCAVATE FOOTINGS TO COMPETENT BEARING
PER THE GEOTECHNICAL ENGINEER AND PROVIDE COMPACTED BACKFILL PER
THE GEOTECHNICAL ENGINEER OR PROJECT SPECIFICATIONS. THE
GEOTECHNICAL ENGINEER SHALL APPROVE FOOTING EXCAVATION /
PREPARATION PRIOR TO PLACEMENT OF ALL FOOTINGS. FOOTING DEPTHS AND
ELEVATIONS SHOWN ON DRAWINGS ARE MINIMUM AND FOR GUIDANCE ONLY;
CONTRACTOR SHALL ESTABLISH ACTUAL ELEVATIONS IN FIELD. BACKFILL BEHIND
ALL WALLS AND PROVIDE FOR SUBSURFACE DRAINAGE AS RECOMMENDED IN THE
GEOTECHNICAL REPORT AND SPECIFICATIONS.
SOIL PROFILE TYPE SITE CLASS “C”
ALLOWABLE VERTICAL DESIGN PRESSURE: 6,000 PSF
LATERAL EARTH PRESSURE, LEVEL BACKFILL:
UNRESTRAINED (ACTIVE): 40 PCF
RESTRAINED (AT-REST) 55 PCF
ALLOWABLE PASSIVE PRESSURE 250 PCF, FS = 1.5
ALLOWABLE FRICTION COEFFICIENT: 0.27, FS = 1.5
SHOP DRAWINGS AND SUBMITTALS:
1. SHOP DRAWINGS SHALL BE PREPARED AND SUBMITTED FOR REVIEW BY THE
PARTY DENOTED IN THE SPECIFICATIONS. FOR EACH STRUCTURAL BUILDING
MATERIAL SPECIFIED.
STATEMENT OF SPECIAL INSPECTION:
1. SEE SPEC SECTIONS 014535 - SPECIAL INSPECTIONS AND 014529 - TESTING
LABORATORY SERVICES FOR MATERIALS, WORK, TYPE AND EXTENT OF EACH
SPECIAL INSPECTION OR TEST.
MASONRY ANCHORAGE:
1. POST-INSTALLED MASONRY ANCHORS INTO EXISTING BRICK MASONRY WALLS
SHALL BE THREADED ROD WITH HY-270 BY HILTI, AC100+ GOLD BY DEWALT,
ET-3G BY SIMPSON STRONG-TIE, OR APPROVED EQUAL. PROVIDE SCREEN TUBES
AT ALL EPOXY ANCHORS INTO BRICK MASONRY WALLS. EPOXY ANCHOR AND
SCREEN TUBE ASSEMBLIES SHALL BE PULL TESTED PER MANUFACTURERS
SPECIFICATIONS PRIOR TO INSTALLATION IN ORDER TO VERIFY CAPACITY AND
SPACING.
2. SCREWS INTO CONCRETE OR BRICK FROM LIGHT GAUGE STRONGBACK WALLS
SHALL BE AS NOTED IN THE DETAILS OR APPROVED EQUAL WITH MIN EMBED OF
1 1/2" (UNO).
EXISTING REBAR SCANNING:
THE GENERAL CONTRACTOR SHALL SELECT THE APPROPRIATE SCANNING METHODS
BASED ON THE CONSTRUCTION MEANS AND METHODS REQUIRED TO INSTALL POST-
INSTALLED ANCHORS IN ACCORDANCE WITH DETAILS. GROUND PENETRATING RADAR,
X-RAY, AND MAGNETIC-BASED METHODS ARE ALL ACCEPTABLE METHODS OF
SCANNING. HOWEVER, CERTAIN METHODS MAY HAVE LIMITATIONS AND THE
APPROPRIATE METHODS AND EQUIPMENT MUST BE DETERMINED BY THE
CONTRACTOR PRIOR TO CONSTRUCTION. DO NOT CUT, DAMAGE, OR REMOVE EXISTING
REBAR TO INSTALL ANCHORS.
SHOTCRETE:
SHOTCRETE PROCEDURE SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS, IBC
SECTION 1908 AND ACI 318. REINFORCING LAP SPLICES SHALL BE DETAILED ON SHOP
DRAWINGS. NON-CONTACT LAP SPLICES, IF USED, SHALL HAVE A MAXIMUM CLEAR
SPACE OF 4" BETWEEN BARS.
ES
I
TA
ROF
P
BR
S
LLOF WASH
ER
ES I ONAL NG I N
E
I
TE
28283
NGTON
ME
AN
. O
AL
S
TRUCTUR ENG I N
EE
R
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
BLUE TRIDENT, LLC
900 WINSLOW WAY E, SUITE 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
C :\U se rs
\P Au ra \D es kt op \R ev it
Lo ca l F ile s\ Bl dg
- S tru ct
_a ju lia n2
3E
EY
LW
.rv t 3/
/2
:0
8:
A M
S-001
GENERAL STRUCTURAL NOTES Seismic Retrofit and Renovate Building 11
VA Roseburg Healthcare System
653-107
B11
4/3/2026 BEM AJW
ISSUED FOR
CONSTRUCTION
A
AB ANCHOR BOLT
ABV ABOVE
AC ASPHALT CONCRETE
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
AISC AMERICAN IRON & STEEL INSTITUTE
ALT ALTERNATE/ING
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
ARCH ARCHITECTURAL
ASCE AMERICAN SOCIETY CIVIL
ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING
MATERIALS
AWS AMERICAN WELDING SOCIETY
B
B/ BOTTOM OF
B/DK BOTTOM OF DECK
B/FTG BOTTOM OF FOOTING
BEL BELOW
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOT/B BOTTOM
BRG BEARING
BTWN/BET BETWEEN
C
C CHANNEL
CB CONCRETE BEAM
CJ CONSTRUCTION JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR/CLEARANCE
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS/CONTINUATION
COORD COORDINATE
CP COMPLETE PENETRATION
CRSI CONCRETE REINFORCING STEEL
INSTITUTE
CTR CENTER
D
DBL DOUBLE
DET/DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DK DECK
DL DEAD LOAD
DP DEEP
DWG DRAWING
DWL DOWEL
E
E EARTHQUAKE
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR
ELEV/EL ELEVATION
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F
FDN FOUNDATION
FF FINISH FLOOR
FIN FINISH(ED)
FJ FLOOR JOISTS
FLR FLOOR
FOC FACE OF CONCRETE
FOS FACE OF STUD
FT FOOT/FEET
FTG FOOTING
G
GA GAGE
GALV GALVANIZED
GL GRIDLINE
GSN GENERAL STRUCTURAL NOTES
H
HCT HOLLOW CLAY TILE
HDR HEADER
HK HOOK
HM HOLLOW METAL
HND/HD HAND
HOR/H/HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HVAC HEATING, VENTILATION & AIR
CONDITIONING
I
IBC INTERNATIONAL BUILDING CODE
ICBO INTERNATIONAL CONFERENCE OF
BUILDING OFFICIALS
IJ ISOLATION JOINT
IMF INTERMEDIATE MOMENT FRAME
IN INCH/INCHES
INCL INCLUDE
INFO INFORMATION
INT INTERIOR
J
JST JOIST
JT JOINT
L
L LENGTH
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC LOCATION
LONGIT LONGITUDINAL
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
M
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR/MANUF MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MP&E MECHANICAL, PLUMBING AND
ELECTRICAL
MPH MILES PER HOUR
MTL METAL
N
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
O/C / OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPG/OPNG OPENING
OPP OPPOSITE
P
PERP PERPENDICULAR
PL/P PLATE
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PR PAIR
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PVMT PAVEMENT
Q
QTY QUANTITY
R
RAD RADIUS
REINF REINFORCING
REQD REQUIRED
REV REVISION, REVERSE
RJ ROOF JOIST
RO ROUGH OPENING
S
SCHED SCHEDULE
SECT SECTION
SF SQUARE FEET (FOOT)
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SJ SHRINKAGE JOINT
SJI STEEL JOIST INSTITUTE
SL SLAB
SOG SLAB ON GRADE
SPC SPACE/SPACING
SPECS SPECIFICATIONS
SQ SQUARE
SSMA STEEL STUD MANUFACTURER
ASSOCIATION
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUCT STRUCTURAL
SW SHEAR WALL
SY SQUARE YARD
T
T TOP
T&B TOP AND BOTTOM
T/ TOP OF
T/FTG TOP OF FOOTING
T/STL TOP OF STEEL
THK/t THICK/THICKNESS
THRU THROUGH
TOS TOP OF STEEL
TOT TOTAL
TS TUBE STEEL
TYP TYPICAL
U
UBC UNIFORM BUILDING CODE
UNBAL UNBALANCED
UNO UNLESS NOTED OTHERWISE
URM UNREINFORCED MASONRY
V
VERT/V VERTICAL
VIF VERIFY IN FIELD
W
W/ WITH
W/O WITHOUT
WD WOOD
WDB WELDED DEFORMED BARS
WP WORK POINT
WWF WELDED WIRE FABRIC
ABBREVIATIONS
SYMBOLS
1. SEE SHEET S001 FOR GENERAL STRUCTURAL NOTES.
2. ALL REFERENCE [REF] DIMENSIONS, ELEVATIONS, AND LOCATIONS OF
EXISTING STRUCTURAL COMPONENTS ARE BASED ON INFORMATION
GATHERED FROM ORIGINAL DRAWINGS OR CURSORY FIELD
MEASUREMENTS AND ARE SHOWN FOR GENERAL INFORMATION ONLY.
CONTRACTOR SHALL FIELD MEASURE AND VERIFY ALL CONDITIONS PRIOR
TO COMMENCING ANY WORK. NOTIFY THE VA CONTRACTING OFFICER'S
REPRESENTATIVE (COR) WHERE CONDITIONS VARY FROM THOSE SHOWN.
3. FOR ALL WALLS TO RECEIVE CONCRETE OVERLAY OR LIGHT GAUGE
STRONGBACK, REMOVE ALL ITEMS ATTACHED TO THE EXISTING URM WALL
(CONDUITS, EQUIPMENT, DUCTS, APPURTENANCES ETC) SO THAT THE WORK
CAN OCCUR. THEN RE-ATTACH TO THE FACE OF THE UPGRADE WHEN IT IS
COMPLETE.
- BB
7 8
CC
9 10 11 12 13 14 15
DD
EE
FF
AA
1 4
C.1 C.1
D.9D.9
2 3
HH
JJ
GG
270' - 5" [REF]
25' - 0" [REF] 25' - 0" [REF] 25' - 0" [REF] 12' - 7" [REF] 19' - 9 1/4" [REF] 16' - 0" [REF] 15' - 4" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 15' - 4" [REF] 30' - 10 3/4" [REF]
R
EF
6'
R
EF
R
EF
R
EF
R
EF
R
EF
7'
R
EF
4'
1" [R
EF
6'
R
EF
R
EF
] 3'
R
EF
R
EF
3'
/4
R
EF
R
EF
] 2 3/
4" [R
EF
7'
R
EF
4'
1"
[R
EF
5 6
1998 PEMB
ADDITION
ADDITION
ADDITION
AD
D
IT
IO
N
O
R
IG
IN
AL
B
LD
G
O
R
IG
IN
AL
B
LD
G
ADDITION
ADDITION
ADDITION
ADDITION
ADDITION
ADDITION
S-201
C1
S-201
F1
S-202 F5S-202C5
S-200
C1
S-200S-203
F1
F1
F5 S-501
F1 S-501
F3 S-501
NOT IN
CONTRACT
NOT IN CONTRACT
BUILDING 11A
S-203
C3
S-203 C5
S-203
C1
D9 S-511
F7 S-501
F7 S-501
F9 S-501
F9 S-501
SAWCUT FOR
NEW STRIP FTG,
SEE DETAIL
SAWCUT FOR NEW STRIP
FTG, SEE DETAIL
F3 S-502
PEDESTAL & FTG FOR IMF
SEE DETAILS F3A/S-502 AND F3B/S-502
SAWCUT FOR
NEW STRIP FTG,
SEE DETAIL
(E) SIDEWALK EDGE
6" SOG W/#4 @
18" OC EA WAY
(E) SIDEWALK
EDGE
D9 S-511
SIM
TYP @ IMF
F3 S-501
@ GL-14TYP BTWN
GL-7 TO GL-13
F5A
F5 S-501
SIM
F5
S-501
D9 S-511
SIM
B1 S-502
TYP
F1 S-502
OPP
HD
EXISTING WALL
STRONGBACK WALL
CONCRETE SHEAR WALL
ORIGINAL 1932 BLDG
1967 ADDITION
1976 ADDITIONS
1988 ADDITIONS
1998 ADDITION
UNKNOWN (BTWN 1967-1981)
UNKNOWN (BTWN 1988-1998)
ES
I
TA
ROF
P
BR
S
LLOF WASH
ER
ES I ONAL NG I N
E
I
TE
28283
NGTON
ME
AN
. O
AL
S
TRUCTUR ENG I N
EE
R
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
BLUE TRIDENT, LLC
900 WINSLOW WAY E, SUITE 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
C :\U se rs
\P Au ra \D es kt op \R ev it
Lo ca l F ile s\ Bl dg
- S tru ct
_a ju lia n2
3E
EY
LW
.rv t 3/
/2
:0
8:
A M
S-100
FOUNDATION PLAN Seismic Retrofit and Renovate Building 11
VA Roseburg Healthcare System
653-107
B11
4/3/2026 BEM AJW
ISSUED FOR
CONSTRUCTION
12 1680 24
FOUNDATION NOTES
1/8" = 1'-0"F1 FOUNDATION PLAN
WALL LEGENDPRIOR HISTORY KEY
- BB
7 8
CC
9 10 11 12 13 14 15
DD
EE
FF
AA
1 4
C.1
C.1
D.9D.9
2 3
HH
JJ
GG
5 6
270' - 5" [REF]
25' - 0" [REF] 25' - 0" [REF] 25' - 0" [REF] 12' - 7" [REF] 19' - 9 1/4" [REF] 16' - 0" [REF] 15' - 4" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 15' - 4" [REF] 30' - 10 3/4" [REF]
R
EF
6'
R
EF
R
EF
R
EF
R
EF
R
EF
7'
R
EF
4'
1" [R
EF
6'
R
EF
R
EF
] 3'
R
EF
R
EF
3'
/4
R
EF
R
EF
3/
4" [R
EF
7'
R
EF
4'
1"
[R
EF
1998 PEMB
ADDITION
ADDITION
ADDITION
AD
D
IT
IO
N
O
R
IG
IN
AL
B
LD
G
O
R
IG
IN
AL
B
LD
G
ADDITION
ADDITION
ADDITION
ADDITION
ADDITION
ADDITION
S-201
C1
S-201
F1
S-202 F5S-202C5
S-200
C1
S-200S-203
F1
F1
EXTERIOR
LIGHT-GAUGE
STRONGBACK
INTERIOR LIGHT-
GAUGE STRONGBACK
400S162-54 @ 16" OC INTERIOR LIGHT-GAUGE
STRONGBACK
F5 S-501
INTERIOR LIGHT-GAUGE
STRONGBACK
F1 S-501
F3 S-501
7" SHOTCRETE OR CIP
CONCRETE OVERLAY
7" SHOTCRETE OR CIP
CONCRETE OVERLAY
NOT IN
CONTRACT
116' - 2"
SHOTCRETE GL-C
SHOTCRETESTRONG BACK GL-F
S-203
C3
S-203 C5
S-203
C1
S-511 F1
S-511 F5
OH
TYP
D9 S-511
S-203 F5
F5 S-501
F7 S-501
F7 S-501
F9 S-501
F9 S-501
IM
F-
IM
F-
IM
F-
HSS5X
5X
1/4
S-521 B9F3
S-502
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
S-512 B7
S-512 D7
TYP @ IMF
D9 S-511
SIM
TYP
TYP
@ IMF
D9 S-511
SIM
F5A
SIMF5
S-501
_____________________ TYP @
GL-11 &
GL-12
TYP BTWN
GL-7 TO GL-13
B1 S-502
F3 S-501
SIM @
GL-14
S-512 B7
OH SIM
(E )C
8X
.5
(E )C
8X
.5
TYP
TYP @
IMF
F1 S-502
S-512 B7
D9 S-521
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E)HSS12X2X3/16
(E)HSS12X2X3/16(E
)H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
(E )H
SS12
X2X
3/1
OPP
HD
1. SEE SHEET S001 FOR GENERAL STRUCTURAL NOTES.
2. IMF-"i" = INTERMEDIATE MOMENT FRAME @ GRIDLINE "i", SEE F5/S-203.
3. ALL REFERENCE [REF] DIMENSIONS, ELEVATIONS, AND LOCATIONS OF
EXISTING STRUCTURAL COMPONENTS ARE BASED ON INFORMATION
GATHERED FROM ORIGINAL DRAWINGS OR CURSORY FIELD
MEASUREMENTS AND ARE SHOWN FOR GENERAL INFORMATION ONLY.
CONTRACTOR SHALL FIELD MEASURE AND VERIFY ALL CONDITIONS PRIOR
TO COMMENCING ANY WORK. NOTIFY THE VA CONTRACTING OFFICER'S
REPRESENTATIVE (COR) WHERE CONDITIONS VARY FROM THOSE SHOWN.
4. FOR ALL WALLS TO RECEIVE CONCRETE OVERLAY OR LIGHT GAUGE
STRONGBACK, REMOVE ALL ITEMS ATTACHED TO THE EXISTING URM WALL
(CONDUITS, EQUIPMENT, DUCTS, APPURTENANCES ETC) SO THAT THE
WORK CAN OCCUR. THEN RE-ATTACH TO THE FACE OF THE UPGRADE WHEN
IT IS COMPLETE.
EXISTING WALL
STRONGBACK WALL
CONCRETE SHEAR WALL
1/8" = 1'-0"F1 FLOOR FRAMING PLAN
ES
I
TA
ROF
P
BR
S
LLOF WASH
ER
ES I ONAL NG I N
E
I
TE
28283
NGTON
ME
AN
. O
AL
S
TRUCTUR ENG I N
EE
R
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
BLUE TRIDENT, LLC
900 WINSLOW WAY E, SUITE 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
C :\U se rs
\P Au ra \D es kt op \R ev it
Lo ca l F ile s\ Bl dg
- S tru ct
_a ju lia n2
3E
EY
LW
.rv t 3/
/2
:0
8:
A M
S-101
FLOOR FRAMING PLAN Seismic Retrofit and Renovate Building 11
VA Roseburg Healthcare System
653-107
B11
4/3/2026 BEM AJW
ISSUED FOR
CONSTRUCTION
12 1680 24
FLOOR FRAMING NOTESWALL LEGEND
- BB
7 8
CC
9 10 11 12 13 14 15
DD
EE
FF
AA
1 4
C.1C.1
D.9D.9
2 3
HH
JJ
(E ) R
O O
F
TR
U
SS
(E ) R
O O
F
TR
U
SS
(E ) R
O O
F
TR
U
SS
(E ) R
O O
F
TR
U
SS
(E ) R
O O
F
TR
U
SS
(E ) R
O O
F
TR
U
SS
(E ) R
O O
F
TR
U
SS
GG
5 6
270' - 5" [REF]
25' - 0" [REF] 25' - 0" [REF] 25' - 0" [REF] 12' - 7" [REF] 19' - 9 1/4" [REF] 16' - 0" [REF] 15' - 4" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 14' - 3" [REF] 15' - 4" [REF] 30' - 10 3/4" [REF]
R
EF
6'
R
EF
R
EF
R
EF
R
EF
R
EF
7'
R
EF
4'
1" [R
EF
6'
R
EF
R
EF
] 3'
R
EF
R
EF
3'
/4
R
EF
R
EF
3/
4" [R
EF
7'
R
EF
4'
1"
[R
EF
1998 PEMB
ADDITION
ADDITION
ADDITION
AD
D
IT
IO
N
O
R
IG
IN
AL
B
LD
G
O
R
IG
IN
AL
B
LD
G
ADDITION
ADDITION
ADDITION
ADDITION
ADDITION
ADDITION
S-201
C1
S-201
F1
S-202 F5S-202C5
OUT OF PLANE
ANCHOR @ EA JOIST
OUT OF PLANE
ANCHOR @ EA JOIST
(E) 12J4 STEEL BAR
JOISTS @ 4'-0" OC
(E) X-BRIDGING
OUT OF PLANE
ANCHOR @ EA
X-BRIDGING
(E )W
X4
(E) LEDGER
L3 X 3 X 1/4
(E) LEDGER
L3 X 3 X 1/4
(E) X-BRIDGING
(E) 1 1/2" 22GA
STL DK
OUT OF PLANE
ANCHOR @ EA
JOIST
(E) 12J4 STEEL BAR
JOISTS @ 4'-0" OC
OUT OF PLANE
ANCHOR
5'
4" 5'
4"
4' - 0"4' - 0"
TYP
6' - 0" OUT OF PLANE
ANCHORS @ 6'-0" OC
B1 S-522
B3 S-521
B1 S-521
(E)C7X9.8
(E)C7X9.8
(E)C7X9.8
(E)C7X9.8
(E)C7X9.8
(E)C7X9.8
(E)C7X9.8
(E)C7X9.8
(E)C7X9.8
(E) 3/4"⌀
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN CONTRACT
BUILDING 11A
F5 S-522
B9 S-511
W/1988 REROOF W/1988 REROOF
F3 S-521
TYP @
STRUT
F7 S-521
TYP @ RF
PURLINS
D9 S-522
6'
0"
OUT OF PLANE
ANCHOR
TYP
D1 S-511
TYP
D9
S-522
6'
0"
OUT OF PLANE
ANCHOR
F3 S-521
TYP @
STRUT
F7 S-521
TYP @ RF
PURLIN
OUT OF PLANE
ANCHORS @ TRUSS
BRG, TYP
D1 S-522
@ W16X
D1 S-511
GLS 13-15 ABV@ W16X
D5 S-521
D5 S-522
D1 S-521
GLS 12-15 BEL
F1 S-522
GLS 9.8-12 BEL
D5 S-511
GLS 7-13 ABV
F1 S-521
F1 S-523
F3 S-523
F1 S-523
SIM
1. SEE SHEET S001 FOR GENERAL STRUCTURAL NOTES.
2. ALL REFERENCE [REF] DIMENSIONS, ELEVATIONS, AND LOCATIONS OF
EXISTING STRUCTURAL COMPONENTS ARE BASED ON INFORMATION
GATHERED FROM ORIGINAL DRAWINGS OR CURSORY FIELD
MEASUREMENTS AND ARE SHOWN FOR GENERAL INFORMATION ONLY.
CONTRACTOR SHALL FIELD MEASURE AND VERIFY ALL CONDITIONS PRIOR
TO COMMENCING ANY WORK. NOTIFY THE VA CONTRACTING OFFICER'S
REPRESENTATIVE (COR) WHERE CONDITIONS VARY FROM THOSE SHOWN.
3. FOR ALL WALLS TO RECEIVE CONCRETE OVERLAY OR LIGHT GAUGE
STRONGBACK, REMOVE ALL ITEMS ATTACHED TO THE EXISTING URM WALL
(CONDUITS, EQUIPMENT, DUCTS, APPURTENANCES ETC) SO THAT THE
WORK CAN OCCUR. THEN RE-ATTACH TO THE FACE OF THE UPGRADE WHEN
IT IS COMPLETE.
1/8" = 1'-0"F1 ROOF FRAMING PLAN
ES
I
TA
ROF
P
BR
S
LLOF WASH
ER
ES I ONAL NG I N
E
I
TE
28283
NGTON
ME
AN
. O
AL
S
TRUCTUR ENG I N
EE
R
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
BLUE TRIDENT, LLC
900 WINSLOW WAY E, SUITE 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
C :\U se rs
\P Au ra \D es kt op \R ev it
Lo ca l F ile s\ Bl dg
- S tru ct
_a ju lia n2
3E
EY
LW
.rv t 3/
/2
:0
8:
A M
S-102
ROOF FRAMING PLAN Seismic Retrofit and Renovate Building 11
VA Roseburg Healthcare System
653-107
B11
4/3/2026 BEM AJW
ISSUED FOR
CONSTRUCTION
12 1680 24
ROOF FRAMING NOTES
FIN FLR
EL 0' - 0" [REF]
BOT OF (E) TRUSS
EL 13' - 0" [REF]
7 8 9 10 11 12 13 14 15
STRONGBACK WALL
400S162-54 STUDS @ 16" OC
B9 S-511
D9 S-511
F3 S-502
@ IMF
TYP
TYP
B9 S-521
TYP @ IMF
B/DK
EL 11'-4" [REF]
1. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES.
2. SEE DETAIL C1/S-523 FOR TYP LIGHT GAUGE FRAMING DETAILS.
3. FOR TYP STRONGBACK CONN INFO SEE D3/S-512.
4. FOR TYP REINF CONCRETE OVERLAY CONN INFO SEE D1/S-512 & F1/S-512.
SEE C1/S-202 & F1/S-202 FOR TYP OVERLAY DWL PATTERNS.
5. @ CONC OVERLAY OPGS USE #5 DIAG X 4'-0" PLACED @ 45° ANGLE @ 3" CLR
FROM CORNER, TYP. TRIM STEEL @ HEADS & SILLS SHALL BE (2) #6 @ 3" OC
UNO.
6. FOR ALL WALLS TO RECEIVE CONCRETE OVERLAY OR LIGHT GAUGE
STRONGBACK, REMOVE ALL ITEMS ATTACHED TO THE EXISTING URM WALL
(CONDUITS, EQUIPMENT, DUCTS, APPURTENANCES ETC) SO THAT THE
WORK CAN OCCUR. THEN RE-ATTACH TO THE FACE OF THE UPGRADE WHEN
IT IS COMPLETE.
FIN FLR
EL 0' - 0" [REF]
FIN FLR
EL 0' - 0" [REF]
BOT OF (E) TRUSS
EL 13' - 0" [REF]
BOT OF (E) TRUSS
EL 13' - 0" [REF]
789101112
ADDITION
ADDITION
F1 S-522
STRONGBACK WALL
400S200-68 @ 16" OC
F7 S-501
B/DK
EL 11'-2 3/4" [REF]
B/DK
EL 11'- 2 3/4" [REF]
ES
I
TA
ROF
P
BR
S
LLOF WASH
ER
ES I ONAL NG I N
E
I
TE
28283
NGTON
ME
AN
. O
AL
S
TRUCTUR ENG I N
EE
R
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
BLUE TRIDENT, LLC
900 WINSLOW WAY E, SUITE 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
C :\U se rs
\P Au ra \D es kt op \R ev it
Lo ca l F ile s\ Bl dg
- S tru ct
_a ju lia n2
3E
EY
LW
.rv t 3/
/2
:0
8:
A M
S-200
SHEAR WALL ELEVATIONS Seismic Retrofit and Renovate Building 11
VA Roseburg Healthcare System
653-107
B11
4/3/2026 BEM AJW
ISSUED FOR
CONSTRUCTION
1/4" = 1'-0"C1 SHEAR WALL ELEVATION - GRIDLINE A
SHEAR WALL ELEVATION NOTES
1/4" = 1'-0"F1 SHEAR WALL ELEVATION - GRIDLINE H 6 840 12
BOT OF (E) TRUSS
EL 13' - 0" [REF]
7 8 9 10 11 12 13 14 15
F3 S-501 t CONCRETE OVERLAY = 6"
(3) #6 VERT
CTR @ 3" OC
(3) #6 VERT
CTR @ 3" OC
#5 H
O R
IZ
C
TR
" O C
A
LT
S
ID
ES
D1 S-511
T/FTG =
T/(E)FIN GRADE
8" 1' - 6" 9" @ 18" OC STAGG'D
6" 6" t CONCRETE
OVERLAY = 6"
HOLES FOR DOWELS
EPOXIED INTO EXIST
STEMWALL & FTG #4
H O
R
IZ
C
C A
LT
S
ID
ES
#5 VERT CTR @ 18" OC
2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"
F3 S-502
#3 STIRRUPS @ 12" OC
D7 S-512
B7
S-512
D7 S-512
OPP
HDTYP#3
@ 12" OC
HORIZ CTR
ALT SIDES
(2) #5 VERT
CTR @ 3" OC
F7 S-512
#3 STIRRUPS @ 12" OC
#4
@ 16" OC
HORIZ CTR
ALT SIDES
(2) #5 VERT
CTR @ 3" OC
F1 S-511
B7
S-512
B7 S-512
TYPSIM
T/ (E) OPG
EL 11'-4" [REF]
TYP FOR
REMAINDER
TYP
@ IMF COND
NORTH SIDE
GL-C @ GL'S
9,11 & 13
F3 S-501
SIM TYP
SEE F1/S-511 FOR
REINF @ PILASTERS
2' - 0"
TYP
#5 DWLS
@ 18" OC
#4 VERT CTR
@ 12" OC TYP
F1 S-502
2' - 0"2' - 0"2' - 0"2' - 0" 2' - 0"2' - 0"
TYP
TYP
FIN FLR
EL 0' - 0" [REF]
BOT OF (E) TRUSS
EL 13' - 0" [REF]
789101112131415
B1 S-522
F1 S-501
600S162-68 @ 16" OC STRONGBACK WALL
F3 S-501
SIM @
PILASTER
TYP
D1 S-521
D5 S-511
ABV
BEL GLS 12-15
F5 S-511
BEL GLS 9.8-12
TYP @
STRONGBACK
D5 S-511
ABV
GLS 7-13
S-511 F9
B1 S-521
#4 VERT CTR
@ 12" OC
TRUSS
BRG
B1 S-521
SIM
B7 S-512
SIM
F1 S-502
SIM
2' - 0" 2' - 0"
S-512 F3
6" CONC OVERLAY
S-512 F3
SIM
600S162-68 @ 16" OC
@ (E) W16X
1. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES.
2. SEE DETAIL C1/S-523 FOR TYP LIGHT GAUGE FRAMING DETAILS.
3. FOR TYP STRONGBACK CONN INFO SEE D3/S-512.
4. FOR TYP REINF CONCRETE OVERLAY CONN INFO SEE D1/S-512 & F1/S-512.
SEE C1/S-202 & F1/S-202 FOR TYP OVERLAY DWL PATTERNS.
5. @ CONC OVERLAY OPGS USE #5 DIAG X 4'-0" PLACED @ 45° ANGLE @ 3" CLR
FROM CORNER, TYP. TRIM STEEL @ HEADS & SILLS SHALL BE (2) #6 @ 3" OC
UNO.
6. FOR ALL WALLS TO RECEIVE CONCRETE OVERLAY OR LIGHT GAUGE
STRONGBACK, REMOVE ALL ITEMS ATTACHED TO THE EXISTING URM WALL
(CONDUITS, EQUIPMENT, DUCTS, APPURTENANCES ETC) SO THAT THE
WORK CAN OCCUR. THEN RE-ATTACH TO THE FACE OF THE UPGRADE WHEN
IT IS COMPLETE.
ES
I
TA
ROF
P
BR
S
LLOF WASH
ER
ES I ONAL NG I N
E
I
TE
28283
NGTON
ME
AN
. O
AL
S
TRUCTUR ENG I N
EE
R
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
BLUE TRIDENT, LLC
900 WINSLOW WAY E, SUITE 130
BAINBRIDGE ISLAND, WA 98110
206-972-0645
EMMANUEL (MANNY) BAUTISTA, PE, F.SAME
C :\U se rs
\P Au ra \D es kt op \R ev it
Lo ca l F ile s\ Bl dg
- S tru ct
_a ju lia n2
3E
EY
LW
.rv t 3/
/2
:0
8:
A M
S-201
SHEAR WALL ELEVATIONS Seismic Retrofit and Renovate Building 11
VA Roseburg Healthcare System
653-107
B11
4/3/2026 BEM AJW
ISSUED FOR
CONSTRUCTION
1/4" = 1'-0"C1 SHEAR WALL ELEVATION - GRIDLINE C
1/4" = 1'-0"F1 SHEAR WALL ELEVATION - GRIDLINE F
SHEAR WALL ELEVATION NOTES
6 840 12
1. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES.
2. SEE DETAIL C1/S-523 FOR TYP LIGHT GAUGE FRAMING DETAILS.
3. FOR TYP STRONGBACK CONN INFO SEE D3/S-512.
4. FOR TYP REINF CONCRETE OVERLAY CONN INFO SEE D1/S-512 & F1/S-512.
SEE C1/S-202 & F1/S-202 FOR TYP OVERLAY DWL PATTERNS.
5. @ CONC OVERLAY OPGS USE #5 DIAG X 4'-0" PLACED @ 45° ANGLE @ 3" CLR
FROM CORNER, TYP. TRIM STEEL @ HEADS & SILLS SHALL BE (2) #6 @ 3" OC
UNO.
6. FOR ALL WALLS TO RECEIVE CONCRETE OVERLAY OR LIGHT GAUGE
STRONGBACK, REMOVE ALL ITEMS ATTACHED TO THE EXISTING URM WALL
(CONDUITS, EQUIPMENT, DUCTS, APPURTENANCES ETC) SO THAT THE
WORK CAN OCCUR. THEN RE-ATTACH TO THE FACE OF THE UPGRADE WHEN
IT IS COMPLETE.
FIN FLR
EL 0' - 0" [REF]
FIN FLR
EL 0' - 0" [REF]
BOT OF (E) TRUSS
EL 13' - 0" [REF]
BOT OF (E) TRUSS
EL 13' - 0" [REF]
B C D E FA
ADDITION
ORIGINAL BLDG
(3) #6 VERT
CTR @ 3" OC
#5 VERT CTR
@ 18" OC
(2) #5 VERT CTR
@ 3" OC @ JAMB
#5 VERT CTR
@ 12" OC
(2) #6 VERT CTR
@ 3" OC @ JAMB
#5 VERT CTR
@ 12" OC
(3) #6 VERT
CTR @ 3" OC
#5 VERT CTR
@ 18" OC
(2) #5 VERT CTR
@ 3" OC @ JAMB
#5 VERT CTR
@ 12" OC
#5 VERT CTR
@ 12" OC
TYP
1 1/2" CLR
TYP
1 1/2" CLR
#5 H
O R
IZ
C
C
A
LT
S
ID
ES
t CONCRETE OVERLAY = 7"
#6 VERT CTR
@ 12" OC
F9 S-501
T/FTG =
T/(E) FIN GRADE
8" 1' - 6" 9" @ 18" OC STAGG'D TO GL-F
6"
6" t CONCRETE OVERLAY = 6"
HOLES FOR DOWELS
EPOXIED INTO EXIST
STEMWALL & FTG #4
H O
R
IZ
C
C A
LT
S
ID
ES
#5 VERT CTR @ 18" OC
STRONGBACK WALL
400S162-54 STUDS @ 16" OC
FOR HEAD, SILL & CORNER
REINF SEE SW ELEVATION
NOTE 5
t CONCRETE OVERLAY = 6"
TY
P
U N
O
B/DK
EL 11' - 4" [REF]
RIDGE T/CONC = 27'-10 1/2" +/-
EAVE T/CONC
= 13'-10 1/2" +/-
F7 S-521
#6 CTR @ SLOPE
TOP OF WALL
B/DK
EL 11'-4" [REF]
#5 DWLS
@ 18" OC
FIN FLR
EL 0' - 0" [REF]
BOT OF (E) TRUSS
EL 13' - 0" [REF]
BCDEF A
ADDITION
ORIGINAL BLDG
STRONGBAC…