This document outlines a federal contract opportunity for construction services. The solicitation is numbered 36C10F20R0048 and seeks a contractor to construct a new parking structure at the Veterans Affairs Medical Center in San Juan, Puerto Rico. The selected contractor will be responsible for providing all labor, materials, equipment, and supervision necessary to build the parking structure as defined in the solicitation's plans and specifications. The contracting agency is the Department of Veterans Affairs Office of Construction and Facilities Management.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDITION TO EXISTING PARKING GARAGE, PHASE 5
VAMC SAN JUAN PUERTO RICO
PROJECT NO 672-085C
FINAL SUBMITTAL
July 25, 2020
SPECIFICATIONS VOL. 4
Appendix D Record Documents Phase 4 Parking Garage
Appendix E Record Documents Phase 4 PV System For Reference Only
TimHaahs
Department of Veterans Affairs
VA Caribbean Healthcare System New Parking Structure Phase 4
672-085D Office of Construction and Facilities Management
Carter Concrete Structures 1960 Parker Court Suite C Stone Mountain, GA 30087 T. 770.978.1212 F. 770.978.1267 www.carterstructures.com
X-010
TITLE
RAG RAG04/05/2013 1 204
NEW PARKING STRUCTURE PHASE 4
VA PROJECT NO. 672-085D
100% DRAWINGS SUBMISSION
VA MEDICAL CENTER
SAN JUAN, PUERTO RICO
APRIL 5, 2013
174 WEST WIEUCA ROAD, NW
ATLANTA GA, 30342-3220
404-549-9277
DESIGN/BUILDER:
1960 PARKER COURT
SUITE C
STONE MOUNTAIN, GA 30087
T. 770.978.1212 F. 770.978.1267 www.carterstructures.com
CARTER CONCRETE STRUCTURES
ARCHITECT:
174 WEST WIEUCA ROAD, NE
ATLANTA GA, 30342-3220
404-851-9580 blaengineers.com
STRUCTURAL ENGINEER:
100 ROAD 165. SUITE 604,
GUAYNABO, PR 00968-8053
(787) 707-1350
MECHANICAL ENGINEER:
PO BOX191587
SAN JUAN, PR 00919-1587
(787) 763-0655
ELECTRICAL ENGINEER:
57 SAN JOSE STREET, PH-2,
SAN JUAN, PR 00901
(787) 789-6187
LANDSCAPE ARCHITECT:
414 AVE MUÑOZ RIVERA,
SUITE 11B
HATO REY, PR 00918
(787) 764-4555
ASSOCIATE ARCHITECT:
3495 PEACHTREE PKWY
STE 114-171
SUWANEE, GA 30024
(404) 386-8430
SPECIFICATIONS:
FRANK COLLAZO & ASSOCIATES
CIVIL ENGINEER:
RAFAEL A. GARCIA, ARCHITECT LLC
JOSE CARLOS JOGLAR,
ARQUITECTO, PSC
BROWDER + LEGUIZAMON & ASSOC.
1581 CAVALIERI STREET, SUITE 2
URB. CARIBE
SAN JUAN, PR 00927
JORGE LEDON WEBSTER, PE, PSC
JUAN REQUENA & ASOCIADOS,
INGENIEROS CSPO
OFFICE OF LANDSCAPE
ARCHITECTURE
ARCHITECTURAL TECH SERVICES
MANSIONES DE VILLANOVA
E1-16, CALLE C
SAN JUAN, PUERTO RICO 00926
ENVIRONMENTAL:
LAZO MANGUAL ENGINEERING, PSC
CONSULTANTS TO DESIGN/BUILDER:
(NOT PART OF ARCHITECT'S CONTRACT)
CONSULTANTS TO ARCHITECT:
NO. DESCRIPTION DATE
1 'CONSULTANTS TO THE DESIGN/BUILDER:'
REVISION
05/13/2013
PO BOX 363116
SAN JUAN, PR 00936-3116
(787) 761-2570
GEOTECHNICAL ENGINEER:
JACA & SIERRA ENGINEERING,
PSC
AIR CONDITIONING
ANCHOR B OLT
ACCESS
ADDENDUM
ADJACENT
ABOVE FINISHED FLOOR
AGGREGATE
ALUMI NUM
ALTERNATE
APPROXIMATE (LY)
ASPHALT
AVERAGE
BOARD
BETWEEN
BITUMINOUS
BUILDING
BLOCK
BLOCKING
BULLNOSE
BOTTOM
BEARING
BASEMENT
CABINET
CATCH BASIN
CEMENT
CERAMIC
CUBIC FOOT (FEET)
CAST IRON
CLOSET
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRE TE
CONNECTION
CONTINUE /CONTINUOUS
CARPET
CERAMIC TILE
CENTER
COLD WATER
CUBIC YARD (S)
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DOWNSPOUT
EACH
ELEVATION
ELEVATOR
ESTIMATE (D)
EXISTING
EXPANSION, EXPAND
EXTERIOR
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR
FIRE HOSE CABINET
FACE OF CONCRETE
FACE OF MASONRY
FACE OF PARTITION
FACE OF STUD
FACE OF WALL
FOOT OR FEET
GAUGE
GALLON
GALVANIZED
GRAB BAR
HOSE BIB
HOLLOW CORE
HEIGHT
HOLLOW METAL
HEATING/VENTILATING/
AIR CONDITIONING
HOT WATER
INSIDE DIAMETER
INCH OR INCHES
INTERIOR
JOINT
LINEAR
MAGNETIC
MAXIMUM
MEDICINE CABINET
METAL
MANUFACTURER
MANHOLE
MINIMUM
MISCELLANEOUS
MASONRY OPENING
NUMB ER
NOMINAL
NOT TO SCALE
OUTSIDE DIAMETER
OVERHEAD
OPPOSITE
PERFORATED
PLATE
PAIR
PROPERTY
POUNDS P ER SQUA RE INCH
PAINTED
POLYVINYL CHLORIDE
QUARRY TILE
RETURN AIR
ROOF DRAIN
REINFORCE (D), (ING)
REQUI RED
RESILIENT
RIGHT HAND
ROOM
ROUGH OPE NING
RIGHT-OF-WAY
STAINLESS STEEL
SUPPLY AIR
SANITARY
SOLID CORE
SCHEDULE
SECTION
SQUARE FOOT (FEET)
SHEET
SPECIAL
SPEAKER
SQUARE
STREET
STANDARD
SUSPE NDED
SWITCH
TELEPHONE
TEMPORARY
TYPICAL
UNDERWRITERS' LABORA TORIES
VINYL COMPOSITION TILE
VERTICAL
WEST
WITH
WITHOUT
WEIGHT
WELDED WIRE FABRIC
A/C
AB
ACC
ACOUS
ADD
ADJ
AFF
AGGR
ALUM
ALT
APPROX
ARCH
ASPH
AVG
BD
BET
BIT
BLDG
BLK
BLKG
BM
BN
BOT
BRG
BSMT
CAB
CB
CEM
CER
CF
CI
CL
CLG
CLR
CMU
CO
COL
CONC
CONN
CONT
CPT
CT
CTR
CW
CY
DET
DF
DIA
DIAG
DIM
DS
EA
EL
ELEC
ELEV
EST
EXIST
EXP
EXT
FD
FE
FEC
FF
FHC
FIN
FLR
FOC
FOM
FOP
FOS
FOW
FT
GA
GAL
GALV
GB
HB
HC
HGT
HM
HVAC
HW
ID
IN
INCL
INSUL
INT
JT
LIN
MAG
MAX
MC
MECH
MET
MFR
MH
MIN
MISC
MO
NO
NOM
NTS
OC
OD
OH
OPP
PERF
PL
PR
PROP
PSF
PSI
PT
PTD
PVC
QT
R
RA
RD
REINF
RES
RET
REV
RH
RM
RO
ROW
S/S
SA
SAN
SC
SCH
SECT
SF
SHT
SP
SPEC
SPKR
SQ
ST
STD
SUSP
SW
SYM
TEL
TEMP
THK
TYP
UL
VAR
VCT
VERT
W W/ W/O
WT
WWF
POUNDS PER SQUARE FOOT
MECHANICAL
ADJUST ADJUSTABLE
AP ACCESS PANEL
CG CORNER GUA RD
CJ CONTROL JOINT
DB DOCK B UMPER
EJ EXPANSION JOINT
FLOOR DRAIN
EP ELECTRICAL PANEL
EWC ELECTRIC WATER COOLER
HANDICAPPEDH/C
MEP
SG SPANDREL GLASS
HORIZONTALHORIZ
REQ'D
TOC TOP OF CURB
TOP TOP OF PIER
TOS TOP OF STEEL
TOW TOP OF WALL
WWM WELDED WI RE MESH
ACOUSTIC (AL)
BOC BOTTOM OF CURB
CIP CAST IN PLACE
DEG DEGREES
DL DEAD LOAD
EPDM
DIENE MONOMER
ETHYLENE PROPYLENE
ELECTRIC (AL)
FINISH (ED)
FLOOR (ING)
INCLUDE (ING)
INSULATE (D), (ION)
JUNCTIONJCT
MECHANICAL, ELECTRICAL,
PLUMBING
LF LINEAR FOOT (FEET)
ON CENTER (S)
REVISION (S), REVISED
RETURN, RETAINING
RISER, RADIUS
SPECIFICATION (S)
SYMMETRY (ICAL)
VARIES (ABLE)
THICK (NESS)
TOM TOP OF MASONRY
PRESSURE TREATED
NIC NOT IN CONTRACT
PCF POUNDS PER CUBIC FOOT
ARCHI TECTURAL
BENCHMARK
CLEANOUT
CFMF COLD FORMED METAL FRAMING
A
B
C
D
H
G
F
E
I
J
L M
O
P
Q R
S
T
U V
W
GYPSUM WA LL BOARDGWB
GYP GYPSUM
DOWNDN
D.O. DOOR OP ENING
N
SIMILARSIM
TO BE DETERMINEDTBD
UNLESS NOTED OTHERWISEUNO
CARD READERCR
DC DOOR CONTA CT
DE DELAYED EGRESS
EQ EQUAL
EQUIP EQUIPMENT
EPB EXIT PANIC BAR
ELECTRIC STRIKEES
MAGNETIC LOCKML
REX REQUEST TO EXIT
Name Elevation
A
1 View Name 1/8" = 1'-0"A101
Room name
150 SF
A101
SIM
1i 1hr
A
ZZZ
ROOM TAG
VIEW TAG
BUILDING SECTION
FLOOR LEVEL
COLUMN GRID
CURTAIN WALL PANEL TAG
ITEM TAG
KEYED NOTE
REVISION TAG
DEMOLITION TAG
PARTITION TAG
ITEMS TO BE DEMOLISHED
NEW CONSTRUCTION
DETAIL NUMBER ON SHEET
SHEET NUMBER OF VIEW
SHEET NUMBER OF VIEW
SECTION NUMBER
BREAK LINE
ALIGN
ALIGN ELEMENTS
DOOR TAG
FLOOR ELEVATION
FLOOR NAME
ELEVATION CALLOUT
SHEET NUMBER OF VIEW
ELEVATION NUMBER
SIM
A101
1 DETAIL CALLOUT
SHEET NUMBER OF VIEW
DETAIL NUMBER
ROOM NAME
ROOM NUMBER
ROOM AREA
FIRE RATING
WALL TYPE
A101
DIMENSION
TO COLUMN
CENTERLINE
DIMENSION TO
STUD/ FACE OF
UNFINISHED
CMU/CONCRETE
DIMENSION
TO FINISHED
SURFACE
SYMBOL LEGEND
DIMENSION LEGEND
A101
1 ALTERNATE DETAIL CALLOUT
SHEET NUMBER OF VIEW
DETAIL NUMBER
ABBREVIATION LEGEND
N
PROJECT NORTH ARROW
[W/MAGNETIC NORTH]]
ARCHITECT: CONSULTANT:
Department of Veterans Affairs
Project Title Project Number
Building Number
Drawing Number
DrawnCheckedDate
LocationApproved: Project Director
Drawing Title
Dwg.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
F
E
D
C
B
A o n e e ig h th i n c o e f o o t o n e q u a rt e r in c e f o o t th re ig h s e f o o t o n e h a lf i n c e f o o t th q u a rt rs e f o o t o n e i n c e f o o t o n e a n d o n e h a lf i n ch e e f o o t th h e e f o o t of
VA Caribbean Healthcare System New Parking Structure Phase 4
VA Medical Center
SAN JUAN, PUERTO RICO
672-085D Office of Construction and Facilities Management
DESIGN/BUILD CONRACTOR:
Carter Concrete Structures 1960 Parker Court Suite C Stone Mountain, GA 30087 T. 770.978.1212 F. 770.978.1267 www.carterstructures.com
X-020
INDEX/REVISIONS
RAG RAG04/05/2013 2 204
SHEET INDEX
Sheet Number Sheet Name 06
/2 5/
/2
0/
/1
4/
/0
9/
/1
5/
/1
9/
TY116 LEVEL 6 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY117 LEVEL 7 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY118 LEVEL PH – TELECOM. & SPECIAL SYSTEMS √ √ √
TY121 HOSPITAL LEVEL 1 TELECOMMUNICATIONS &
SPECIAL SYSTEMS
TY122 SITE PLAN TELECOMMUNICATIONS & SPECIAL
SYSTEMS
TY411 FIBER BACKBONE SINGLE LINE DIAGRAM √ √ √
TY412 UTP BACKBONE SINGLE LINE DIAGRAM √ √ √
Grand total: 201
SHEET INDEX
Sheet Number Sheet Name 06
/2 5/
/2
0/
/1
4/
/0
9/
/1
5/
/1
9/
SG002 GENERAL NOTES √ √ √
SB110 FOUNDATION PLAN - STRUCTURAL √ √ √ √ *
SB501 FOUNDATION DETAILS AND SCHEDULE √ √ √ √
SB502 FOUNDATION DETAILS - STRUCTURAL √ √ √ √ *
SB503 SPECIAL PILE CAP DETAILS √ √ √ *
SB504 FOUNDATION DETAILS - STRUCTURAL √ √
SB505 RETAINING WALL ELEVATIONS √ √ *
SF111 LEVEL 1 PLAN - STRUCTURAL √ √ √ √ *
SF112 LEVEL 2 PLAN - STRUCTURAL √ √ √ √
SF113 LEVEL 3 PLAN - STRUCTURAL √ √ √ √
SF114 LEVEL 4 PLAN - STRUCTURAL √ √ √ √
SF115 LEVEL 5 PLAN - STRUCTURAL √ √ √ √
SF116 LEVEL 6 PLAN - STRUCTURAL √ √ √ √
SF117 LEVEL 7 PLAN - STRUCTURAL √ √ √ √
SF118 PENTHOUSE AND ROOF PLANS √ √ *
SF119 STAIRWELL FLOOR PLANS √
SF511 MISC PT BEAM - COLUMN DETAILS √ √ √ √ *
SF521 PT SLAB DETAILS - STRUCTURAL √ √ √ √
SF531 PT BEAM SCHEDULE AND DETAILS √ √ √ √
SF532 STRUCTURAL BEAM DIAGRAMS √ √ √ *
SF533 STRUCTURAL BEAM DIAGRAMS √ √ √
SF534 STRUCTURAL BEAM DIAGRAMS √ √
SF535 STRUCTURAL BEAM DIAGRAMS √ √ *
SF536 STRUCTURAL BEAM DIAGRAMS √ √
SF541 PT FRAMING DETAILS - STRUCTURAL √ √ √ √
SF542 PT FRAMING DETAILS - STRUCTURAL √ √ √ √
SF545 SKYWALK FRAMING DETAILS √ √ *
SF546 SKYWALK FRAMING DETAILS - BEAM DIAGRAMS √ √ *
SF551 SHEAR WALL PLANS √ √ √
SF552 SHEAR WALL PLANS √ √ √
SF561 STANDARD & MISC DETAILS - STRUCTURAL √ √ √ √
SF562 STANDARD & MISC DETAILS - STRUCTURAL √ √ √ √
M - 111 PARKING LEVEL #1 MECHANICAL LAYOUT √ √ √
M - 112 PARKING LEVEL #2 MECHANICAL LAYOUT √ √ √
M - 113 PARKING LEVEL #3 MECHANICAL LAYOUT √ √ √
M - 114 PARKING LEVEL #4 MECHANICAL LAYOUT √ √ √
M - 115 PARKING LEVEL #5 MECHANICAL LAYOUT √ √ √
M - 116 PARKING LEVEL #6 MECHANICAL LAYOUT √ √ √
M - 117 PARKING LEVEL #7 MECHANICAL LAYOUT √ √ √
M - 118 PENTHOUSE & ELEVATOR ROOF MECHANICAL
LAYOUT
M - 301 RISER & CONTROL DIAGRAMS MECHANICAL √ √ √
M - 302 A/C CONTROL DIAGRAMS √
M - 501 DETAILS √ √ √
M - 601 SCHEDULES & SYMBOL LIST √ √ √
P - 111 PARKING LEVEL #1 PLUMBING LAYOUT √ √ √ √
P - 112 PARKING LEVEL #3 PLUMBING LAYOUT √ √ √ √
P - 113 PARKING LEVEL #2 PLUMBING LAYOUT √ √ √ √
P - 114 PARKING LEVEL #4 PLUMBING LAYOUT √ √ √ √
P - 115 PARKING LEVEL #5 PLUMBING LAYOUT √ √ √ √
P - 116 PARKING LEVEL #6 PLUMBING LAYOUT √ √ √ √
P - 117 PARKING LEVEL #7 PLUMBING LAYOUT √ √ √ √
P - 118 PENTHOUSE, STAIR & ELEV. ROOF PLUMBING
LAYOUT
P - 301 PLUMBING RISER DIAGRAM √ √ √
P - 302 PLUMBING AND STANDPIPES RISER DIAGRAM √ √ √
P - 303 FIRE PROTECTION RISER DIAGRAM √ √ √
P - 503 PLUMBIND DETAILS √
P - 501 PLUMBING DETAILS √ √ √
P - 502 PLUMBING DETAILS √
P - 901 SCHEDULES, LEGEND AND GENERAL NOTES √ √ √
EJ100 ELECTRICAL SITE PLAN √ √ √
EL111 LEVEL 1 PLAN - LIGHTING √ √ √ √
EL112 LEVEL 2 PLAN - LIGHTING √ √ √ √
EL113 LEVEL 3 PLAN - LIGHTING √ √ √ √
EL114 LEVEL 4 PLAN - LIGHTING √ √ √ √
EL115 LEVEL 5 PLAN - LIGHTING √ √ √ √
EL116 LEVEL 6 PLAN - LIGHTING √ √ √ √
EL117 LEVEL 7 & PENTHOUSE PLAN - LIGHTING √ √ √ √
EP111 LEVEL 1 PLAN - POWER √ √ √ √
EP112 LEVEL 2 PLAN - POWER √ √ √ √
EP113 LEVEL 3 PLAN - POWER √ √ √ √
EP114 LEVEL 4 PLAN - POWER √ √ √ √
EP115 LEVEL 5 PLAN - POWER √ √ √ √
EP116 LEVEL 6 PLAN - POWER √ √ √ √
EP117 LEVEL 7 PLAN - POWER √ √ √ √
FA111 LEVEL 1 PLAN - FIRE ALARM √ √ √ √
FA112 LEVEL 2 PLAN - FIRE ALARM √ √ √ √
FA113 LEVEL 3 PLAN - FIRE ALARM √ √ √ √
FA114 LEVEL 4 PLAN - FIRE ALARM √ √ √ √
FA115 LEVEL 5 PLAN - FIRE ALARM √ √ √ √
FA116 LEVEL 6 PLAN - FIRE ALARM √ √ √ √
FA117 LEVEL 7 & PENTHOUSE PLAN - FIRE ALARM √ √ √ √
EJ301 PROPOSED POWER ONE-LINE DIAGRAM √ √ √ √
EJ302 FIRE ALARM RISER DIAGRAM √ √ √
EJ501 ELECTRICAL DETAILS √ √ √
EJ601 SCHEDULES & SYMBOL LIST √ √ √ √
EJ602 ELECTRICAL NOTES √ √ √
EJ603 PANEL SCHEDULES & SWITCHING PANEL √ √ √
TY001 TELECOMMUNICATIONS & SPECIAL SYSTEMS
SYMBOLS LEGEND
TY002 TELECOMMUNICATIONS & SPECIAL SYSTEMS
DETAILS
TY003 TELECOMMUNICATIONS & SPECIAL SYSTEMS
PATHWAYS SINGLE LINE DIAGRAM
TY004 TELECOMMUNICATIONS GROUNDING &
BOUNDING SINGLE LINE DIAGRAM
TY111 LEVEL 1 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY112 LEVEL 2 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY113 LEVEL 3 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY114 LEVEL 4 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY115 LEVEL 5 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
SHEET INDEX
Sheet Number Sheet Name 06
/2 5/
/2
0/
/1
4/
/0
9/
/1
5/
/1
9/
X-010 TITLE √ √ √ √ √
X-020 INDEX/REVISIONS √ √ √ √ √
X-030 CODE SUMMARY √ √ √ √ √
L - 01 PLANTING & IRRIGATION PLAN – SOUTH SIDE √ √ √
L - 02 PLANTING PLAN – NORTH SIDE √ √ √
VF - 101 EXISTING CONDITIONS SURVEY √ √ √
CD - 101 DEMOLITION PLAN √ √ √
C - 101 GEOMETRIC LAYOUT PLAN √ √ √
C - 102 GEOMETRIC LAYOUT PLAN √ √ √
C - 501 CIVIL MISCELLANEOUS DETAILS √ √ √
C - 502 CIVIL MISCELLANEOUS DETAILS √ √ √
C - 503 STREET SECTIONS √ √ √
C - 504 DRIVEWAY R2 PROFILE √ √ √
CG - 101 GRADING PLAN √ √ √
CG - 102 GRADING PLAN √ √ √
CI - 301 RETAINING WALL NO. 1 √ √ √ *
CI - 301A RETAINING WALL NO. 1 *
CI - 302 STAIRCASE DETAILS √ √ √
CI - 303 STRUCTURAL STAIR DETAILS √ √ √
CI - 304 MESA RETAINING WALL NO. 2 SECTION √ √ √
CI - 305 MESA RETAINING WALL NOTES √ √ √
CI - 306 MESA RETAINING WALL DETAILS √ √ √
CI - 307 MESA RETAINING WALL CONSTRUCTION
SEQUENCE
CG - 103 C.E.S. PLAN √ √ √
CG - 104 C.E.S. PLAN √ √ √
CU - 101 WATER DISTRIBUTION PLAN √ √ √
CU - 102 WATER DISTRIBUTION PLAN √ √ √
CU - 501 WATER DISTRIBUTION DETAILS √ √ √
CU - 103 SANITARY SEWER PLAN √ √ √
CU - 104 SANITARY SEWER PLAN √ √ √
CU - 502 SANITARY SEWER PROFILES √ √ √
CU - 503 SANITARY SEWER DETAILS √ √ √
CU - 105 STORM SEWER PLAN √ √ √
CU - 106 STORM SEWER PLAN √ √ √
CU - 504 STORM SEWER PROFILES √ √ √
CU - 505 STORM SEWER DETAILS √ √ √
CU - 506 STORM SEWER DETAILS √ √ √
CU - 507 STORM SEWER DETAILS √ √ √
CU - 508 STORM SEWER DETAILS √ √
CP - 201 TRAFFIC MAINTENANCE PLAN √ √ √
CP - 202 TRAFFIC MAINTENANCE PLAN √ √ √
CP - 203 TRAFFIC MAINTENANCE PLAN √ √ √
CP - 204 TRAFFIC WARNING SIGNS √ √ √
CP - 205 TRAFFIC SIGNAGE PLAN √ √ √
CP - 206 TRAFFIC SIGNAGE PLAN √ √ √
CP - 207 TRAFFIC PERMANENT SIGN √ √ √
CX - 301 GENERAL CONDITIONS FOR SECURITY √ √ √
AE-032 LIFE SAFETY PLANS √ √ √
AE-110 LAYOUT PLAN, LEVEL 1 √ √ √
AE-111 LEVEL 1 STRIPING PLAN √ √ √ √ √
AE-120 LAYOUT PLAN, LEVEL 2 √ √ √
AE-121 LEVEL 2 STRIPING PLAN √ √ √ √ √
AE-130 LAYOUT PLAN, LEVEL 3 √ √ √
AE-131 LEVEL 3 STRIPING PLAN √ √ √ √ √
AE-140 LAYOUT PLAN, LEVEL 4 √ √ √
AE-141 LEVEL 4 STRIPING PLAN √ √ √ √ √
AE-150 LAYOUT PLAN, LEVEL 5 √ √ √
AE-151 LEVEL 5 STRIPING PLAN √ √ √ √ √
AE-160 LAYOUT PLAN, LEVEL 6 √ √ √
AE-161 LEVEL 6 STRIPING PLAN √ √ √ √ √
AE-170 LAYOUT PLAN, LEVEL 7 √ √ √
AE-171 LEVEL 7 STRIPING PLAN √ √ √ √ √
AE-172 PV DECKS - PLANS √ √ √
DE-501 PLAN DETAILS √ √ √
DE-502 CISTERN DETAIL √ √
DE-503 DRAIN AND WATERPROOFING DETAILS √ √ √
AE-210 BUILDING ELEVATIONS (S,W) √ √ √ √ √
AE-220 BUILDING ELEVATIONS (N, E) √ √ √ √ √
AE-300 BUILDING SECTIONS √ √ √ √ √
AE-301 BUILDING SECTIONS √ √
AE-310 EXTERIOR WALL SECTIONS √ √ √
AE-311 INTERIOR WALL SECTIONS √ √ √
AE-320 BRIDGE SECTIONS √ √ √
AE-321 BRIDGE SECTION & DETAILS √ √ √
AE-322 BRIDGE SECTIONS & DETAILS √ √ √
AE-410 ELEVATOR LOBBY PLANS √ √ √ √ √
AE-411 ELEVATOR LOBBY PLANS √ √ √ √ √
AE-412 ELEVATOR LOBBY PLANS √ √ √
AE-413 ELEVATOR LOBBY ELEVATIONS √ √ √
AE-414 ELEVATOR LOBBY SECTION, DETAILS √ √ √ √ √
AE-415 ELEVATOR LOBBY INTERIOR ELEVATIONS √ √ √
AE-420 STAIR 1 PLANS √ √ √ √ √
AE-421 STAIR 1 ELEVATIONS, SECTION √ √ √ √ √
DE-504 STAIR DETAILS √ √ √
AE-430 BRIDGE PLANS √ √ √ √ √
AE-431 BRIDGE ELEVATIONS √ √ √ √ √
AE-440 ACCESSIBLE WALKWAY AND FALL PREVENTION
GRILLE PLANS AND DETAILS
AE-441 SLAB DRAIN LOCATION ENLARGED PLANS √ √ √
AE-450 MECHANICAL/TELECOM ROOMS √ √ √
AE-460 GUARDHOUSE √ √ √
DE-505 CURTAIN WALL DETAILS √ √ √
DE-506 BUILDING DETAILS √ √
DE-507 WALL TYPES √ √ √
DE-560 GRILLE, MESH, AND EXTERIOR FINISH DETAILS &
SCHEDULES
DE-561 DOOR AND HARDWARE DETAILS & SCHEDULES √ √ √
DE-562 ACCESSORY DETAILS & SCHEDULES √ √ √
AF-600 ROOM FINISH AND OMNICLASS SCHEDULES √ √ √
SG001 GENERAL NOTES √ √ √ √ *
* = SHEETS ISSUED AS REVISIONS TO PREVIOUSLY RELEASED DRAWINGS.
NO. DESCRIPTION DATE
1 INDEX REVISION 07/01/2013
BUILDING DATA:
CONSTRUCTION TYPE:
BUILDING HEIGHT:
BUILDING AREA/ FLOOR:
TOTAL BUILDING AREA:
TOTAL EXITING DISTANCE:
LOW HAZARD STORAGE, S2
1B (OPEN PARKING STRUCTURE)
158' 7"
300'
PARKING COUNT: OPEN PARKING GARAGE CALCULATIONS: PER REQUIREMENTS OF 2009 IBC, 406.3.3.1
• "STANDARD" FALL/SUICIDE PREVENTION GRILLE (90.3% OPEN) = 16327.17 SF x .903 = 14741.63 SF OF EQUIVALENT OPEN AREA
• "AVERAGE" MESH - ASSUMING 50% EACH TYPE - (70.50% OPEN) = 8159.05 SF x .705 = 5752.13 SF OF EQUIVALENT OPEN AREA
20493.76 SF OF EQUIVALENT OPEN AREA 20493.76 SF/ 80805.54 SF(TOTAL AREA) = 25.36 % OPEN
• AT 25+% OPEN, ACCORDING TO 2009 IBC CODE REQUIREMENTS PER 406.3.3.1, DECK QUALIFIES AS AN "OPEN PARKING GARAGE."
V.A. Caribbean Healthcare System New Parking Structure – Phase 4 VA No. 672-085D
APPLICABLE CODES:
Building Code – International Building Code (IBC 2009) with 2011 Puerto Rico Building Code Amendments Life Safety Code – NFPA 101 Life Safety Code (2009) Fire Code – NFPA National Fire Codes, not including NFPA 5000 and NFPA 900 Mechanical Code – International Mechanical Code (IBC 2009) Electrical Code – National Electrical Code (NEC 2009) Plumbing Code – National Standard Plumbing Code (NSPC 2009) Accessibility Standards– Uniform Federal Accessibility Standards (UFAS) Dept. of Veterans Affairs Barrier Free Design Guide PG-18-13 (with selected exemptions granted by VA, listed below) 2010 ADA Standards for Accessible Design Seismic Requirements – Dept. of Veterans Affairs Seismic Design Requirements H-18-8 Elevator Code – Safety Code for Elevators and Escalators, ASME A 17.1 Miscellaneous Other Standards and Codes – Occupational, Safety and Health Administration (OSHA) Standards Building Code Requirements for Reinforced Concrete, ACI 318 Energy Policy Act of 2005 (EPAct) Ventilation for Acceptable Indoor Quality – ASHRAE Standard 62.1-2004 Other applicable trade-specific standards and codes will be detailed in each consultant’s Documents.
In general, such standards are referenced, and are part of, the codes listed above.
1. IBC 2009 with 2011 PR Building Code Amendments
Chapter 3 – 311.1 Use and Occupancy – Low Hazard Storage, Group S2 Chapter 4 – 406.3 Open Parking Garage, Type IB Construction, Ramp Access, Exterior wall openings of 20% of perimeter wall area/wall/tier, 40% of tier perimeter minimum, interior walls 20% open, Openings evenly distributed. Unlimited area per tier allowed, 12 tiers maximum.
Chapter 5 – Building Height and Area per 406.3, above.
Table 508.4 Required Separation of Occupancies – Separation between Existing hospital breezeway (I2 occupancy) and Skywalk bridge structure Of this Project (S2 Occupancy) allowed to be 2 hours if Skywalk fully Sprinklered per 903.3.1.1 Chapter 6 – Fire-Resistance requirements per Table 601: Structural Frame 2hr., Bearing Walls 2hr., Ext. Non-Bearing Walls 1hr. for 30’-0” or less separation, Floor 2 hr., Roof 1 hr.
Combustible Materials per 603: Insulation FS 25 maximum, Roof Coverings A,B,C Class.
Chapter 7 – Opening Protectives per Table 705.8: for separation of:
3’-NP, 5’ – 15%, 10’-25%, 15’ – 45%, 20’ – 75%, 30’ –NL,
Elevator Hoistway Enclosure not required per 708.2.14, Enclosed Elevator Lobby not required per 708.14.1.2, Opening Protectives per Section 715. Skywalk openings omitted at 30’-0” closest to hospital to comply with 705.0 Chapter 8 – No Comment Chapter 9 – Sprinkler System not required. (see Chapter 5 for Skywalk exception) 903.3.1.1- Skywalk sprinkler system to be installed per NFPA 13 Class I Manual Standpipe System per [F]905.1, exception 2.
Hose Thread connections to be reviewed and approved by local Fire department per [F]905.1 Portable Fire Extinguishers provided per VA RFP requirement:
Ordinary /Moderate Hazard per NFPA 10, Class B Flammables 20B Extinguishers, 50’-0” travel distance to extinguisher.
Chapter 10 – Total area per floor = 47,763 sf, 239 occupants/floor (200 sf/occ. Table 1004.1.1) Total Occupants: 239 x 7 levels = 1673 occupants total.
Minimum Stair Width = 239/2 x .3” = 36” per 1005.1, Minimum allowable stair width is 44” per 1009.1 Minimum Accessible Means of Egress stair width is 48” Per 1007.3 (two Accessible Means of Egress required by 1007.1) Area of Refuge not required at stairs per 1007.3.5 Accessible Means of Egress provided by elevator per VA, Area of Refuge not required at elevator per 1007.4.1.
Chapter 11 – Accessible Route required, all floors. 60% of entrances to be Accessible Entrances. 2% 0f all parking spaces to be accessible.
One of every six accessible spaces to be an accessible van space.
Passenger elevators on an accessible route to be accessible.
Chapter 12 – Refer to MEP Documents Chapter 13 – Refer to HVAC Documents Chapter 14 – No Comment Chapter 15 – Exterior walls and roofs of penthouses to be non-combustible.
Chapter 16 – Refer to Structural Documents Chapter 17 – Refer to Structural Documents Chapter 18 – Refer to Structural Documents Chapter 19 – Refer to Structural Documents Chapter 20 – Refer to Structural Documents Chapter 21 – Refer to Structural Documents Chapter 22 – Refer to Structural Documents Chapter 23 – N/A Chapter 24 – No Comment Chapter 25 – No Comment Chapter 26 – No Comment Chapter 27 – Refer to Electrical Documents Chapter 28 – Refer to Mechanical Documents Chapter 29 – Refer to Plumbing Documents Chapter 30 – Elevator Shaft Enclosures – not required (708.2.14), no rating (see NFPA 101, Ch. 8, below) Glass in elevator hoistways to be laminated per ANSI Z97.1 or CPSC 16 CFR Chapter 31 – N/A Chapter 32 – N/A Chapter 33 – N/A Chapter 34 – N/A Chapter 35 – No Comment
2. NFP 101 Life Safety Code (2009)
Chapter 6 - 6.1.13.1 Storage Occupancy. 6.1.14.4.1(b) 2 hr separation from Healthcare Chapter 7 - 7’-6” min ht. at Means of Egress, level. 6’-8” min ht. at stairs. Maximum Abrupt change in floor level ¼”, ½” if top ¼” has 45 degree bevel. Slip Resistant surfaces required at Means of Egress. Min Tread 11”. Max riser Ht. 7”, Max ht. between landings 12’-0”, Landings Equal in width to stair width, max. 48”plus Area of Refuge at Accessible Means of Egress. Handrails shall be continuous, within 30” of width, 30” to 38” above tread.
Clearance of 2 ¼” from wall required. Maximum handrail projection into stair width 4 ½”. Non-continuous handrails project 12” beyond top riser and depth of one Tread beyond bottom riser. Stair width 0.3”/occupant, Ramp width 0.2”/Occupant. Two Means of Egress required (less than 500 Oc/fl) separated by ½ diagonal of floor, min. Two Accessible Means of Egress required (7.5.4.1). 48” clear stair width required (Accessible Means of Egress).
Chapter 8 - No Comment Chapter 9 - Elevator machine Room to be ventilated per 9.4.5.
Chapter 10 - No Comment Chapters 11- 41 – N/A Chapter 41 - Table 42.2.5: Max Dead End Corridor 50’, Common Path of Travel 50’, Table 42.8.2.6.1: Maximum Travel Distance to Exits 300’.
42.8.3.4.1(2): Fire Alarm System not required.
3. Uniform Federal Accessibility Standards, [V.A. Barrier Free Design Guide PG-18-13]
Chapter 4 - 4.1.1(5)(e)(iii) : 20% of all spaces to be Accessible Spaces in SCI facilities.
4.3: Accessible Route required from public transport, accessible spaces, Accessible loading zones, public sidewalks to building entrance. An Accessible Route to connect all accessible buildings and facilities on site.
Minimum Accessible Route width 36”[Modified by PG-18-13, page 1, to 60”] The VA has allowed the Design/Build Team a variation of PG-18-13 To “approximately 4’-0” at columns” – RFI D0006 Response, 08/16/2012, on file with Architect. In addition, Item 10, August 22, 2012 Letter from VA allows “encroachments every 22’ [to] narrow the accessible route to about 4’ wide for a two foot length…” 4.4.1: Protruding objects 27” to 80” AFF cannot project more than 4” into Walking surfaces.
4.4.2: 80” minimum headroom at walking surfaces.
4.6.3: Accessible Parking Spaces to be 96” wide min with one adjacent 60” Access Aisle [Modified by PG-18-13, page 2, to two 60” aisles]
The VA has Allowed the Design/Build Team a variation of PG-18-13 to accept Accessible Parking Spaces and Accessible SCI/PVA Parking Spaces with only one 60” Accessible Access Aisle where shear walls and columns interfere in the Plan provided to the Design/Build Team by the VA. The clear width of the Access Aisles is allowed to be reduced to 36” (ADA Accessible Route) where The PG-18-13 required second Access Aisle is blocked by building structure - RFI D0006 Response, 08/16/2012, on file with Architect. In addition, refer to Item 7., August 22, 2012 letter from VA, citing compliance with ADA as sufficient.
4.6.4: Passenger Loading Zones shall have Accessible Access Aisles 60” wide and 20’-0” long adjacent and parallel to Vehicle space.
4.3.7: Maximum slope at Accessible Route 1:20 (5%) [Modified by PG-18-13, page 1, to 1:33 (3%)], Maximum Cross-Slope of Accessible Route 1:50 (2%).
4.10.3: Elevator Call Buttons 42” AFF to bottom,
4.10.4 (1): Elevator Hall Lanterns 72” AFF to bottom. Door maneuvering clearances per Fig. 24, UFAS [Modified by PG-18-13, page 1, to 6’x6’].
4. Safety Code for Elevators and Escalators, ASME A 17.1
Part 2 - 2.1.6: Hoistway Enclosures shall have flush surfaces on the hoistway side.
2.1.6.2 (a): 75 degree slope on projections into hoistway of more than 4”.
Beveled material over flat projections to be per 2.1.6.2 (d) 1, 2, 3.
For other codes listed above, please refer to each Design Discipline’s Contract Documents.
The following variances from the Appendix A Design Parameters of the RFP Documents have been granted to the Design/Build Team by the VA in the 08/16/2012 Response to RFI D0006 and Additional Comments To RFI D-006 dated August 22, 2012 and August 29, 2012.
1. Page 10, Item 4a:” 60’-0” parking modules typically consisting of a 24’ wide two way traffic aisle with 90 [degree] parking spaces on each side.” Slight variation from the driving aisle dimension has been allowed by the VA.
2. Page 10, Item 4b: “Typically, parking spaces are 9’-0” wide by 18’-0” long, providing comfortable and convenient parking”. Variations in length of 1’-0” and in width of 2’-8” have been allowed by the VA due to column intrusions. In addition some spaces are allowed to be shortened by column/shear wall combinations to a greater degree.
3. Page 10, Item 4c: “End bay turning aisles are 26’ wide”.: Smaller end bay turning aisle radii are acceptable by the VA, as shown in the RFP documents.
4. Page 11, Item 6: “Of these 1/6 are van accessible at 11’-0” wide by 18’-0” long with a 5’-0” access aisle on each side of the space. The remaining spaces are 8’-0” wide by 18’-0” long with a 5’-0” access aisle on each side of the space.” Variations in length and width of these spaces because of 1’-0”x 2’-8” column intrusions have been allowed by the VA. Some spaces will have only one functional access aisle (see PG-18-13 modifications allowed by the VA, above).
5. Page 11, Item 6: “…11 spaces must be van accessible at 11’-0” wide by 21’-0” long.” Shorter or narrower dimensions in part of these spaces have been allowed by the VA due to 1’-0” x 2’-8”column and shear wall intrusions in the RFP documents.
ARCHITECT: CONSULTANT:
Department of Veterans Affairs
Revisions: Date:
Project Title Project Number
Building Number
Drawing Number
DrawnCheckedDate
LocationApproved: Project Director
Drawing Title
Dwg.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
F
E
D
C
B
A o n e e ig h th i n f o t o n e q u a rt e r in o t th h o t o n e h a lf i n o t th a rt o t o n e i n o t o n e a d a lf i n c h e o t th h e o t of
VA Caribbean Healthcare System New Parking Structure Phase 4
VA Medical Center
SAN JUAN, PUERTO RICO
672-085D Office of Construction and Facilities Management
DESIGN/BUILD CONRACTOR:
Carter Concrete Structures 1960 Parker Court Suite C Stone Mountain, GA 30087 T. 770.978.1212 F. 770.978.1267 www.carterstructures.com
X-030
CODE SUMMARY
RAG RAG04/05/2013 3 204
Area Schedule (Gross Building) Level Area
LEVEL 1 47145 SF
LEVEL 2 46345 SF
LEVEL 3 46345 SF
LEVEL 4 49100 SF
LEVEL 5 46345 SF
LEVEL 6 46354 SF
LEVEL 7 42373 SF
PENTHOUSE 1633 SF
325641 SF
ARCHITECT: CONSULTANT:
Department of Veterans Affairs
Project Title Project Number
Building Number
Drawing Number
DrawnCheckedDate
LocationApproved: Project Director
Drawing Title
Dwg.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
F
E
D
C
B
A o n e e ig c e f o o t o n e q u a rt e f o o t th h e f o o t o n e h a lf i n c e f o o t th a rt e f o o t o n e i n c e f o o t o n e a n d o n e h a lf i n ch e e f o o t th h e e f o o t of
VA Caribbean Healthcare System New Parking Structure Phase 4
VA Medical Center
SAN JUAN, PUERTO RICO
672-085D Office of Construction and Facilities Management
DESIGN/BUILD CONRACTOR:
Carter Concrete Structures 1960 Parker Court Suite C Stone Mountain, GA 30087 T. 770.978.1212 F. 770.978.1267 www.carterstructures.com
X-010
TITLE
RAG RAG04/05/2013 1 204
NEW PARKING STRUCTURE PHASE 4
VA PROJECT NO. 672-085D
100% DRAWINGS SUBMISSION
VA MEDICAL CENTER
SAN JUAN, PUERTO RICO
APRIL 5, 2013
174 WEST WIEUCA ROAD, NW
ATLANTA GA, 30342-3220
404-549-9277
DESIGN/BUILDER:
1960 PARKER COURT
SUITE C
STONE MOUNTAIN, GA 30087
T. 770.978.1212 F. 770.978.1267 www.carterstructures.com
CARTER CONCRETE STRUCTURES
ARCHITECT:
174 WEST WIEUCA ROAD, NE
ATLANTA GA, 30342-3220
404-851-9580 blaengineers.com
STRUCTURAL ENGINEER:
100 ROAD 165. SUITE 604,
GUAYNABO, PR 00968-8053
(787) 707-1350
MECHANICAL ENGINEER:
PO BOX191587
SAN JUAN, PR 00919-1587
(787) 763-0655
ELECTRICAL ENGINEER:
57 SAN JOSE STREET, PH-2,
SAN JUAN, PR 00901
(787) 789-6187
LANDSCAPE ARCHITECT:
414 AVE MUÑOZ RIVERA,
SUITE 11B
HATO REY, PR 00918
(787) 764-4555
ASSOCIATE ARCHITECT:
3495 PEACHTREE PKWY
STE 114-171
SUWANEE, GA 30024
(404) 386-8430
SPECIFICATIONS:
FRANK COLLAZO & ASSOCIATES
CIVIL ENGINEER:
RAFAEL A. GARCIA, ARCHITECT LLC
JOSE CARLOS JOGLAR,
ARQUITECTO, PSC
BROWDER + LEGUIZAMON & ASSOC.
1581 CAVALIERI STREET, SUITE 2
URB. CARIBE
SAN JUAN, PR 00927
JORGE LEDON WEBSTER, PE, PSC
JUAN REQUENA & ASOCIADOS,
INGENIEROS CSPO
OFFICE OF LANDSCAPE
ARCHITECTURE
ARCHITECTURAL TECH SERVICES
MANSIONES DE VILLANOVA
E1-16, CALLE C
SAN JUAN, PUERTO RICO 00926
ENVIRONMENTAL:
LAZO MANGUAL ENGINEERING, PSC
CONSULTANTS TO DESIGN/BUILDER:
(NOT PART OF ARCHITECT'S CONTRACT)
CONSULTANTS TO ARCHITECT:
PO BOX 363116
SAN JUAN, PR 00936-3116
(787) 761-2570
GEOTECHNICAL ENGINEER:
JACA & SIERRA ENGINEERING,
PSC
NO. DESCRIPTION DATE
1 'CONSULTANTS TO THE DESIGN/BUILDER:'
REVISION
05/13/2013
AIR CONDITIONING
ANCHOR B OLT
ACCESS
ADDENDUM
ADJACENT
ABOVE FINISHED FLOOR
AGGREGATE
ALUMI NUM
ALTERNATE
APPROXIMATE (LY)
ASPHALT
AVERAGE
BOARD
BETWEEN
BITUMINOUS
BUILDING
BLOCK
BLOCKING
BULLNOSE
BOTTOM
BEARING
BASEMENT
CABINET
CATCH BASIN
CEMENT
CERAMIC
CUBIC FOOT (FEET)
CAST IRON
CLOSET
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRE TE
CONNECTION
CONTINUE /CONTINUOUS
CARPET
CERAMIC TILE
CENTER
COLD WATER
CUBIC YARD (S)
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DOWNSPOUT
EACH
ELEVATION
ELEVATOR
ESTIMATE (D)
EXISTING
EXPANSION, EXPAND
EXTERIOR
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR
FIRE HOSE CABINET
FACE OF CONCRETE
FACE OF MASONRY
FACE OF PARTITION
FACE OF STUD
FACE OF WALL
FOOT OR FEET
GAUGE
GALLON
GALVANIZED
GRAB BAR
HOSE BIB
HOLLOW CORE
HEIGHT
HOLLOW METAL
HEATING/VENTILATING/
AIR CONDITIONING
HOT WATER
INSIDE DIAMETER
INCH OR INCHES
INTERIOR
JOINT
LINEAR
MAGNETIC
MAXIMUM
MEDICINE CABINET
METAL
MANUFACTURER
MANHOLE
MINIMUM
MISCELLANEOUS
MASONRY OPENING
NUMB ER
NOMINAL
NOT TO SCALE
OUTSIDE DIAMETER
OVERHEAD
OPPOSITE
PERFORATED
PLATE
PAIR
PROPERTY
POUNDS P ER SQUA RE INCH
PAINTED
POLYVINYL CHLORIDE
QUARRY TILE
RETURN AIR
ROOF DRAIN
REINFORCE (D), (ING)
REQUI RED
RESILIENT
RIGHT HAND
ROOM
ROUGH OPE NING
RIGHT-OF-WAY
STAINLESS STEEL
SUPPLY AIR
SANITARY
SOLID CORE
SCHEDULE
SECTION
SQUARE FOOT (FEET)
SHEET
SPECIAL
SPEAKER
SQUARE
STREET
STANDARD
SUSPE NDED
SWITCH
TELEPHONE
TEMPORARY
TYPICAL
UNDERWRITERS' LABORA TORIES
VINYL COMPOSITION TILE
VERTICAL
WEST
WITH
WITHOUT
WEIGHT
WELDED WIRE FABRIC
A/C
AB
ACC
ACOUS
ADD
ADJ
AFF
AGGR
ALUM
ALT
APPROX
ARCH
ASPH
AVG
BD
BET
BIT
BLDG
BLK
BLKG
BM
BN
BOT
BRG
BSMT
CAB
CB
CEM
CER
CF
CI
CL
CLG
CLR
CMU
CO
COL
CONC
CONN
CONT
CPT
CT
CTR
CW
CY
DET
DF
DIA
DIAG
DIM
DS
EA
EL
ELEC
ELEV
EST
EXIST
EXP
EXT
FD
FE
FEC
FF
FHC
FIN
FLR
FOC
FOM
FOP
FOS
FOW
FT
GA
GAL
GALV
GB
HB
HC
HGT
HM
HVAC
HW
ID
IN
INCL
INSUL
INT
JT
LIN
MAG
MAX
MC
MECH
MET
MFR
MH
MIN
MISC
MO
NO
NOM
NTS
OC
OD
OH
OPP
PERF
PL
PR
PROP
PSF
PSI
PT
PTD
PVC
QT
R
RA
RD
REINF
RES
RET
REV
RH
RM
RO
ROW
S/S
SA
SAN
SC
SCH
SECT
SF
SHT
SP
SPEC
SPKR
SQ
ST
STD
SUSP
SW
SYM
TEL
TEMP
THK
TYP
UL
VAR
VCT
VERT
W W/ W/O
WT
WWF
POUNDS PER SQUARE FOOT
MECHANICAL
ADJUST ADJUSTABLE
AP ACCESS PANEL
CG CORNER GUA RD
CJ CONTROL JOINT
DB DOCK B UMPER
EJ EXPANSION JOINT
FLOOR DRAIN
EP ELECTRICAL PANEL
EWC ELECTRIC WATER COOLER
HANDICAPPEDH/C
MEP
SG SPANDREL GLASS
HORIZONTALHORIZ
REQ'D
TOC TOP OF CURB
TOP TOP OF PIER
TOS TOP OF STEEL
TOW TOP OF WALL
WWM WELDED WI RE MESH
ACOUSTIC (AL)
BOC BOTTOM OF CURB
CIP CAST IN PLACE
DEG DEGREES
DL DEAD LOAD
EPDM
DIENE MONOMER
ETHYLENE PROPYLENE
ELECTRIC (AL)
FINISH (ED)
FLOOR (ING)
INCLUDE (ING)
INSULATE (D), (ION)
JUNCTIONJCT
MECHANICAL, ELECTRICAL,
PLUMBING
LF LINEAR FOOT (FEET)
ON CENTER (S)
REVISION (S), REVISED
RETURN, RETAINING
RISER, RADIUS
SPECIFICATION (S)
SYMMETRY (ICAL)
VARIES (ABLE)
THICK (NESS)
TOM TOP OF MASONRY
PRESSURE TREATED
NIC NOT IN CONTRACT
PCF POUNDS PER CUBIC FOOT
ARCHI TECTURAL
BENCHMARK
CLEANOUT
CFMF COLD FORMED METAL FRAMING
A
B
C
D
H
G
F
E
I
J
L M
O
P
Q R
S
T
U V
W
GYPSUM WA LL BOARDGWB
GYP GYPSUM
DOWNDN
D.O. DOOR OP ENING
N
SIMILARSIM
TO BE DETERMINEDTBD
UNLESS NOTED OTHERWISEUNO
CARD READERCR
DC DOOR CONTA CT
DE DELAYED EGRESS
EQ EQUAL
EQUIP EQUIPMENT
EPB EXIT PANIC BAR
ELECTRIC STRIKEES
MAGNETIC LOCKML
REX REQUEST TO EXIT
Name Elevation
A
1 View Name 1/8" = 1'-0"A101
Room name
150 SF
A101
SIM
1i 1hr
A
ZZZ
ROOM TAG
VIEW TAG
BUILDING SECTION
FLOOR LEVEL
COLUMN GRID
CURTAIN WALL PANEL TAG
ITEM TAG
KEYED NOTE
REVISION TAG
DEMOLITION TAG
PARTITION TAG
ITEMS TO BE DEMOLISHED
NEW CONSTRUCTION
DETAIL NUMBER ON SHEET
SHEET NUMBER OF VIEW
SHEET NUMBER OF VIEW
SECTION NUMBER
BREAK LINE
ALIGN
ALIGN ELEMENTS
DOOR TAG
FLOOR ELEVATION
FLOOR NAME
ELEVATION CALLOUT
SHEET NUMBER OF VIEW
ELEVATION NUMBER
SIM
A101
1 DETAIL CALLOUT
SHEET NUMBER OF VIEW
DETAIL NUMBER
ROOM NAME
ROOM NUMBER
ROOM AREA
FIRE RATING
WALL TYPE
A101
DIMENSION
TO COLUMN
CENTERLINE
DIMENSION TO
STUD/ FACE OF
UNFINISHED
CMU/CONCRETE
DIMENSION
TO FINISHED
SURFACE
SYMBOL LEGEND
DIMENSION LEGEND
A101
1 ALTERNATE DETAIL CALLOUT
SHEET NUMBER OF VIEW
DETAIL NUMBER
ABBREVIATION LEGEND
N
PROJECT NORTH ARROW
[W/MAGNETIC NORTH]]
ARCHITECT: CONSULTANT:
Department of Veterans Affairs
Project Title Project Number
Building Number
Drawing Number
DrawnCheckedDate
LocationApproved: Project Director
Drawing Title
Dwg.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
F
E
D
C
B
A o n e e ig c e f o o t o n e q u a rt e f o o t th h e f o o t o n e h a lf i n c e f o o t th a rt e f o o t o n e i n c e f o o t o n e a n d o n e h a lf i n ch e e f o o t th h e e f o o t of
VA Caribbean Healthcare System New Parking Structure Phase 4
VA Medical Center
SAN JUAN, PUERTO RICO
672-085D Office of Construction and Facilities Management
DESIGN/BUILD CONRACTOR:
Carter Concrete Structures 1960 Parker Court Suite C Stone Mountain, GA 30087 T. 770.978.1212 F. 770.978.1267 www.carterstructures.com
X-020
INDEX/REVISIONS
RAG RAG04/05/2013 2 204
SHEET INDEX
Sheet Number Sheet Name 06
/2 5/
/2
0/
/1
4/
/0
9/
/1
5/
/1
9/
TY116 LEVEL 6 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY117 LEVEL 7 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY118 LEVEL PH – TELECOM. & SPECIAL SYSTEMS √ √ √
TY121 HOSPITAL LEVEL 1 TELECOMMUNICATIONS &
SPECIAL SYSTEMS
TY122 SITE PLAN TELECOMMUNICATIONS & SPECIAL
SYSTEMS
TY411 FIBER BACKBONE SINGLE LINE DIAGRAM √ √ √
TY412 UTP BACKBONE SINGLE LINE DIAGRAM √ √ √
Grand total: 201
SHEET INDEX
Sheet Number Sheet Name 06
/2 5/
/2
0/
/1
4/
/0
9/
/1
5/
/1
9/
SG002 GENERAL NOTES √ √ √
SB110 FOUNDATION PLAN - STRUCTURAL √ √ √ √ *
SB501 FOUNDATION DETAILS AND SCHEDULE √ √ √ √
SB502 FOUNDATION DETAILS - STRUCTURAL √ √ √ √ *
SB503 SPECIAL PILE CAP DETAILS √ √ √ *
SB504 FOUNDATION DETAILS - STRUCTURAL √ √
SB505 RETAINING WALL ELEVATIONS √ √ *
SF111 LEVEL 1 PLAN - STRUCTURAL √ √ √ √ *
SF112 LEVEL 2 PLAN - STRUCTURAL √ √ √ √
SF113 LEVEL 3 PLAN - STRUCTURAL √ √ √ √
SF114 LEVEL 4 PLAN - STRUCTURAL √ √ √ √
SF115 LEVEL 5 PLAN - STRUCTURAL √ √ √ √
SF116 LEVEL 6 PLAN - STRUCTURAL √ √ √ √
SF117 LEVEL 7 PLAN - STRUCTURAL √ √ √ √
SF118 PENTHOUSE AND ROOF PLANS √ √ *
SF119 STAIRWELL FLOOR PLANS √
SF511 MISC PT BEAM - COLUMN DETAILS √ √ √ √ *
SF521 PT SLAB DETAILS - STRUCTURAL √ √ √ √
SF531 PT BEAM SCHEDULE AND DETAILS √ √ √ √
SF532 STRUCTURAL BEAM DIAGRAMS √ √ √ *
SF533 STRUCTURAL BEAM DIAGRAMS √ √ √
SF534 STRUCTURAL BEAM DIAGRAMS √ √
SF535 STRUCTURAL BEAM DIAGRAMS √ √ *
SF536 STRUCTURAL BEAM DIAGRAMS √ √
SF541 PT FRAMING DETAILS - STRUCTURAL √ √ √ √
SF542 PT FRAMING DETAILS - STRUCTURAL √ √ √ √
SF545 SKYWALK FRAMING DETAILS √ √ *
SF546 SKYWALK FRAMING DETAILS - BEAM DIAGRAMS √ √ *
SF551 SHEAR WALL PLANS √ √ √
SF552 SHEAR WALL PLANS √ √ √
SF561 STANDARD & MISC DETAILS - STRUCTURAL √ √ √ √
SF562 STANDARD & MISC DETAILS - STRUCTURAL √ √ √ √
M - 111 PARKING LEVEL #1 MECHANICAL LAYOUT √ √ √
M - 112 PARKING LEVEL #2 MECHANICAL LAYOUT √ √ √
M - 113 PARKING LEVEL #3 MECHANICAL LAYOUT √ √ √
M - 114 PARKING LEVEL #4 MECHANICAL LAYOUT √ √ √
M - 115 PARKING LEVEL #5 MECHANICAL LAYOUT √ √ √
M - 116 PARKING LEVEL #6 MECHANICAL LAYOUT √ √ √
M - 117 PARKING LEVEL #7 MECHANICAL LAYOUT √ √ √
M - 118 PENTHOUSE & ELEVATOR ROOF MECHANICAL
LAYOUT
M - 301 RISER & CONTROL DIAGRAMS MECHANICAL √ √ √
M - 302 A/C CONTROL DIAGRAMS √
M - 501 DETAILS √ √ √
M - 601 SCHEDULES & SYMBOL LIST √ √ √
P - 111 PARKING LEVEL #1 PLUMBING LAYOUT √ √ √ √
P - 112 PARKING LEVEL #3 PLUMBING LAYOUT √ √ √ √
P - 113 PARKING LEVEL #2 PLUMBING LAYOUT √ √ √ √
P - 114 PARKING LEVEL #4 PLUMBING LAYOUT √ √ √ √
P - 115 PARKING LEVEL #5 PLUMBING LAYOUT √ √ √ √
P - 116 PARKING LEVEL #6 PLUMBING LAYOUT √ √ √ √
P - 117 PARKING LEVEL #7 PLUMBING LAYOUT √ √ √ √
P - 118 PENTHOUSE, STAIR & ELEV. ROOF PLUMBING
LAYOUT
P - 301 PLUMBING RISER DIAGRAM √ √ √
P - 302 PLUMBING AND STANDPIPES RISER DIAGRAM √ √ √
P - 303 FIRE PROTECTION RISER DIAGRAM √ √ √
P - 503 PLUMBIND DETAILS √
P - 501 PLUMBING DETAILS √ √ √
P - 502 PLUMBING DETAILS √
P - 901 SCHEDULES, LEGEND AND GENERAL NOTES √ √ √
EJ100 ELECTRICAL SITE PLAN √ √ √
EL111 LEVEL 1 PLAN - LIGHTING √ √ √ √
EL112 LEVEL 2 PLAN - LIGHTING √ √ √ √
EL113 LEVEL 3 PLAN - LIGHTING √ √ √ √
EL114 LEVEL 4 PLAN - LIGHTING √ √ √ √
EL115 LEVEL 5 PLAN - LIGHTING √ √ √ √
EL116 LEVEL 6 PLAN - LIGHTING √ √ √ √
EL117 LEVEL 7 & PENTHOUSE PLAN - LIGHTING √ √ √ √
EP111 LEVEL 1 PLAN - POWER √ √ √ √
EP112 LEVEL 2 PLAN - POWER √ √ √ √
EP113 LEVEL 3 PLAN - POWER √ √ √ √
EP114 LEVEL 4 PLAN - POWER √ √ √ √
EP115 LEVEL 5 PLAN - POWER √ √ √ √
EP116 LEVEL 6 PLAN - POWER √ √ √ √
EP117 LEVEL 7 PLAN - POWER √ √ √ √
FA111 LEVEL 1 PLAN - FIRE ALARM √ √ √ √
FA112 LEVEL 2 PLAN - FIRE ALARM √ √ √ √
FA113 LEVEL 3 PLAN - FIRE ALARM √ √ √ √
FA114 LEVEL 4 PLAN - FIRE ALARM √ √ √ √
FA115 LEVEL 5 PLAN - FIRE ALARM √ √ √ √
FA116 LEVEL 6 PLAN - FIRE ALARM √ √ √ √
FA117 LEVEL 7 & PENTHOUSE PLAN - FIRE ALARM √ √ √ √
EJ301 PROPOSED POWER ONE-LINE DIAGRAM √ √ √ √
EJ302 FIRE ALARM RISER DIAGRAM √ √ √
EJ501 ELECTRICAL DETAILS √ √ √
EJ601 SCHEDULES & SYMBOL LIST √ √ √ √
EJ602 ELECTRICAL NOTES √ √ √
EJ603 PANEL SCHEDULES & SWITCHING PANEL √ √ √
TY001 TELECOMMUNICATIONS & SPECIAL SYSTEMS
SYMBOLS LEGEND
TY002 TELECOMMUNICATIONS & SPECIAL SYSTEMS
DETAILS
TY003 TELECOMMUNICATIONS & SPECIAL SYSTEMS
PATHWAYS SINGLE LINE DIAGRAM
TY004 TELECOMMUNICATIONS GROUNDING &
BOUNDING SINGLE LINE DIAGRAM
TY111 LEVEL 1 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY112 LEVEL 2 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY113 LEVEL 3 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY114 LEVEL 4 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
TY115 LEVEL 5 - TELECOM. & SPECIAL SYSTEMS √ √ √ √
SHEET INDEX
Sheet Number Sheet Name 06
/2 5/
/2
0/
/1
4/
/0
9/
/1
5/
/1
9/
X-010 TITLE √ √ √ √ √
X-020 INDEX/REVISIONS √ √ √ √ √
X-030 CODE SUMMARY √ √ √ √ √
L - 01 PLANTING & IRRIGATION PLAN – SOUTH SIDE √ √ √
L - 02 PLANTING PLAN – NORTH SIDE √ √ √
VF - 101 EXISTING CONDITIONS SURVEY √ √ √
CD - 101 DEMOLITION PLAN √ √ √
C - 101 GEOMETRIC LAYOUT PLAN √ √ √
C - 102 GEOMETRIC LAYOUT PLAN √ √ √
C - 501 CIVIL MISCELLANEOUS DETAILS √ √ √
C - 502 CIVIL MISCELLANEOUS DETAILS √ √ √
C - 503 STREET SECTIONS √ √ √
C - 504 DRIVEWAY R2 PROFILE √ √ √
CG - 101 GRADING PLAN √ √ √
CG - 102 GRADING PLAN √ √ √
CI - 301 RETAINING WALL NO. 1 √ √ √ *
CI - 301A RETAINING WALL NO. 1 *
CI - 302 STAIRCASE DETAILS √ √ √
CI - 303 STRUCTURAL STAIR DETAILS √ √ √
CI - 304 MESA RETAINING WALL NO. 2 SECTION √ √ √
CI - 305 MESA RETAINING WALL NOTES √ √ √
CI - 306 MESA RETAINING WALL DETAILS √ √ √
CI - 307 MESA RETAINING WALL CONSTRUCTION
SEQUENCE
CG - 103 C.E.S. PLAN √ √ √
CG - 104 C.E.S. PLAN √ √ √
CU - 101 WATER DISTRIBUTION PLAN √ √ √
CU - 102 WATER DISTRIBUTION PLAN √ √ √
CU - 501 WATER DISTRIBUTION DETAILS √ √ √
CU - 103 SANITARY SEWER PLAN √ √ √
CU - 104 SANITARY SEWER PLAN √ √ √
CU - 502 SANITARY SEWER PROFILES √ √ √
CU - 503 SANITARY SEWER DETAILS √ √ √
CU - 105 STORM SEWER PLAN √ √ √
CU - 106 STORM SEWER PLAN √ √ √
CU - 504 STORM SEWER PROFILES √ √ √
CU - 505 STORM SEWER DETAILS √ √ √
CU - 506 STORM SEWER DETAILS √ √ √
CU - 507 STORM SEWER DETAILS √ √ √
CU - 508 STORM SEWER DETAILS √ √
CP - 201 TRAFFIC MAINTENANCE PLAN √ √ √
CP - 202 TRAFFIC MAINTENANCE PLAN √ √ √
CP - 203 TRAFFIC MAINTENANCE PLAN √ √ √
CP - 204 TRAFFIC WARNING SIGNS √ √ √
CP - 205 TRAFFIC SIGNAGE PLAN √ √ √
CP - 206 TRAFFIC SIGNAGE PLAN √ √ √
CP - 207 TRAFFIC PERMANENT SIGN √ √ √
CX - 301 GENERAL CONDITIONS FOR SECURITY √ √ √
AE-032 LIFE SAFETY PLANS √ √ √
AE-110 LAYOUT PLAN, LEVEL 1 √ √ √
AE-111 LEVEL 1 STRIPING PLAN √ √ √ √ √
AE-120 LAYOUT PLAN, LEVEL 2 √ √ √
AE-121 LEVEL 2 STRIPING PLAN √ √ √ √ √
AE-130 LAYOUT PLAN, LEVEL 3 √ √ √
AE-131 LEVEL 3 STRIPING PLAN √ √ √ √ √
AE-140 LAYOUT PLAN, LEVEL 4 √ √ √
AE-141 LEVEL 4 STRIPING PLAN √ √ √ √ √
AE-150 LAYOUT PLAN, LEVEL 5 √ √ √
AE-151 LEVEL 5 STRIPING PLAN √ √ √ √ √
AE-160 LAYOUT PLAN, LEVEL 6 √ √ √
AE-161 LEVEL 6 STRIPING PLAN √ √ √ √ √
AE-170 LAYOUT PLAN, LEVEL 7 √ √ √
AE-171 LEVEL 7 STRIPING PLAN √ √ √ √ √
AE-172 PV DECKS - PLANS √ √ √
DE-501 PLAN DETAILS √ √ √
DE-502 CISTERN DETAIL √ √
DE-503 DRAIN AND WATERPROOFING DETAILS √ √ √
AE-210 BUILDING ELEVATIONS (S,W) √ √ √ √ √
AE-220 BUILDING ELEVATIONS (N, E) √ √ √ √ √
AE-300 BUILDING SECTIONS √ √ √ √ √
AE-301 BUILDING SECTIONS √ √
AE-310 EXTERIOR WALL SECTIONS √ √ √
AE-311 INTERIOR WALL SECTIONS √ √ √
AE-320 BRIDGE SECTIONS √ √ √
AE-321 BRIDGE SECTION & DETAILS √ √ √
AE-322 BRIDGE SECTIONS & DETAILS √ √ √
AE-410 ELEVATOR LOBBY PLANS √ √ √ √ √
AE-411 ELEVATOR LOBBY PLANS √ √ √ √ √
AE-412 ELEVATOR LOBBY PLANS √ √ √
AE-413 ELEVATOR LOBBY ELEVATIONS √ √ √
AE-414 ELEVATOR LOBBY SECTION, DETAILS √ √ √ √ √
AE-415 ELEVATOR LOBBY INTERIOR ELEVATIONS √ √ √
AE-420 STAIR 1 PLANS √ √ √ √ √
AE-421 STAIR 1 ELEVATIONS, SECTION √ √ √ √ √
DE-504 STAIR DETAILS √ √ √
AE-430 BRIDGE PLANS √ √ √ √ √
AE-431 BRIDGE ELEVATIONS √ √ √ √ √
AE-440 ACCESSIBLE WALKWAY AND FALL PREVENTION
GRILLE PLANS AND DETAILS
AE-441 SLAB DRAIN LOCATION ENLARGED PLANS √ √ √
AE-450 MECHANICAL/TELECOM ROOMS √ √ √
AE-460 GUARDHOUSE √ √ √
DE-505 CURTAIN WALL DETAILS √ √ √
DE-506 BUILDING DETAILS √ √
DE-507 WALL TYPES √ √ √
DE-560 GRILLE, MESH, AND EXTERIOR FINISH DETAILS &
SCHEDULES
DE-561 DOOR AND HARDWARE DETAILS & SCHEDULES √ √ √
DE-562 ACCESSORY DETAILS & SCHEDULES √ √ √
AF-600 ROOM FINISH AND OMNICLASS SCHEDULES √ √ √
SG001 GENERAL NOTES √ √ √ √ *
* = SHEETS ISSUED AS REVISIONS TO PREVIOUSLY RELEASED DRAWINGS.
1 INDEX REVISION 07/01/2013
BUILDING DATA:
CONSTRUCTION TYPE:
BUILDING HEIGHT:
BUILDING AREA/ FLOOR:
TOTAL BUILDING AREA:
TOTAL EXITING DISTANCE:
LOW HAZARD STORAGE, S2
1B (OPEN PARKING STRUCTURE)
158' 7"
300'
PARKING COUNT: OPEN PARKING GARAGE CALCULATIONS: PER REQUIREMENTS OF 2009 IBC, 406.3.3.1
MESH SF · (% Open) + MESH SF · (% Open) + FALL PROTECTION GRILLE SF · (% Open) + FENCING · (% Open) + UNOBSTRUCTED OPENING = TOTAL OPENNESS OF PARKING GARAGE STRUCTURESCALECUBIST
1665.05 · (74%) + 2575.93 · (62%) 17440.00 · (90.67%) +2388.51 · (90%*) + 414 · (100%) = 21205.7206 SFSF 21205.7206 SF TOTAL OPENNESS OF PARKING GARAGE STRUCTURE
80805.54 SF TOTAL WALL AREA
≈ 0.26283 ≈ 26.3% ≥ 20%20% THIS STRUCTURE QUALIFIES AS AN "OPEN PARKING STRUCTURE" PER IBC 2009.
*ASSUMED OPENNESS OF CHAIN LINK MESH
V.A. Caribbean Healthcare System New Parking Structure – Phase 4 VA No. 672-085D
APPLICABLE CODES:
Building Code – International Building Code (IBC 2009) with 2011 Puerto Rico Building Code Amendments Life Safety Code – NFPA 101 Life Safety Code (2009) Fire Code – NFPA National Fire Codes, not including NFPA 5000 and NFPA 900 Mechanical Code – International Mechanical Code (IBC 2009) Electrical Code – National Electrical Code (NEC 2009) Plumbing Code – National Standard Plumbing Code (NSPC 2009) Accessibility Standards– Uniform Federal Accessibility Standards (UFAS) Dept. of Veterans Affairs Barrier Free Design Guide PG-18-13 (with selected exemptions granted by VA, listed below) 2010 ADA Standards for Accessible Design Seismic Requirements – Dept. of Veterans Affairs Seismic Design Requirements H-18-8 Elevator Code – Safety Code for Elevators and Escalators, ASME A 17.1 Miscellaneous Other Standards and Codes – Occupational, Safety and Health Administration (OSHA) Standards Building Code Requirements for Reinforced Concrete, ACI 318 Energy Policy Act of 2005 (EPAct) Ventilation for Acceptable Indoor Quality – ASHRAE Standard 62.1-2004 Other applicable trade-specific standards and codes will be detailed in each consultant’s Documents.
In general, such standards are referenced, and are part of, the codes listed above.
1. IBC 2009 with 2011 PR Building Code Amendments
Chapter 3 – 311.1 Use and Occupancy – Low Hazard Storage, Group S2 Chapter 4 – 406.3 Open Parking Garage, Type IB Construction, Ramp Access, Exterior wall openings of 20% of perimeter wall area/wall/tier, 40% of tier perimeter minimum, interior walls 20% open, Openings evenly distributed. Unlimited area per tier allowed, 12 tiers maximum.
Chapter 5 – Building Height and Area per 406.3, above.
Table 508.4 Required Separation of Occupancies – Separation between Existing hospital breezeway (I2 occupancy) and Skywalk bridge structure Of this Project (S2 Occupancy) allowed to be 2 hours if Skywalk fully Sprinklered per 903.3.1.1 Chapter 6 – Fire-Resistance requirements per Table 601: Structural Frame 2hr., Bearing Walls 2hr., Ext. Non-Bearing Walls 1hr. for 30’-0” or less separation, Floor 2 hr., Roof 1 hr.
Combustible Materials per 603: Insulation FS 25 maximum, Roof Coverings A,B,C Class.
Chapter 7 – Opening Protectives per Table 705.8: for separation of:
3’-NP, 5’ – 15%, 10’-25%, 15’ – 45%, 20’ – 75%, 30’ –NL,
Elevator Hoistway Enclosure not required per 708.2.14, Enclosed Elevator Lobby not required per 708.14.1.2, Opening Protectives per Section 715. Skywalk openings omitted at 30’-0” closest to hospital to comply with 705.0 Chapter 8 – No Comment Chapter 9 – Sprinkler System not required. (see Chapter 5 for Skywalk exception) 903.3.1.1- Skywalk sprinkler system to be installed per NFPA 13 Class I Manual Standpipe System per [F]905.1, exception 2.
Hose Thread connections to be reviewed and approved by local Fire department per [F]905.1 Portable Fire Extinguishers provided per VA RFP requirement:
Ordinary /Moderate Hazard per NFPA 10, Class B Flammables 20B Extinguishers, 50’-0” travel distance to extinguisher.
Chapter 10 – Total area per floor = 47,763 sf, 239 occupants/floor (200 sf/occ. Table 1004.1.1) Total Occupants: 239 x 7 levels = 1673 occupants total.
Minimum Stair Width = 239/2 x .3” = 36” per 1005.1, Minimum allowable stair width is 44” per 1009.1 Minimum Accessible Means of Egress stair width is 48” Per 1007.3 (two Accessible Means of Egress required by 1007.1) Area of Refuge not required at stairs per 1007.3.5 Accessible Means of Egress provided by elevator per VA, Area of Refuge not required at elevator per 1007.4.1.
Chapter 11 – Accessible Route required, all floors. 60% of entrances to be Accessible Entrances. 2% 0f all parking spaces to be accessible.
One of every six accessible spaces to be an accessible van space.
Passenger elevators on an accessible route to be accessible.
Chapter 12 – Refer to MEP Documents Chapter 13 – Refer to HVAC Documents Chapter 14 – No Comment Chapter 15 – Exterior walls and roofs of penthouses to be non-combustible.
Chapter 16 – Refer to Structural Documents Chapter 17 – Refer to Structural Documents Chapter 18 – Refer to Structural Documents Chapter 19 – Refer to Structural Documents Chapter 20 – Refer to Structural Documents Chapter 21 – Refer to Structural Documents Chapter 22 – Refer to Structural Documents Chapter 23 – N/A Chapter 24 – No Comment Chapter 25 – No Comment Chapter 26 – No Comment Chapter 27 – Refer to Electrical Documents Chapter 28 – Refer to Mechanical Documents Chapter 29 – Refer to Plumbing Documents Chapter 30 – Elevator Shaft Enclosures – not required (708.2.14), no rating (see NFPA 101, Ch. 8, below) Glass in elevator hoistways to be laminated per ANSI Z97.1 or CPSC 16 CFR Chapter 31 – N/A Chapter 32 – N/A Chapter 33 – N/A Chapter 34 – N/A Chapter 35 – No Comment
2. NFP 101 Life Safety Code (2009)
Chapter 6 - 6.1.13.1 Storage Occupancy. 6.1.14.4.1(b) 2 hr separation from Healthcare Chapter 7 - 7’-6” min ht. at Means of Egress, level. 6’-8” min ht. at stairs. Maximum Abrupt change in floor level ¼”, ½” if top ¼” has 45 degree bevel. Slip Resistant surfaces required at Means of Egress. Min Tread 11”. Max riser Ht. 7”, Max ht.
between landings 12’-0”, Landings Equal in width to stair width, max. 48”plus Area of Refuge at Accessible Means of Egress. Handrails shall be continuous, within 30” of width, 30” to 38” above tread. Clearance of 2 ¼” from wall required. Maximum handrail projection into stair width 4 ½”. Non-continuous handrails project 12” beyond top riser and depth of one Tread beyond bottom riser. Stair width 0.3”/occupant, Ramp width 0.2”/Occupant. Two Means of Egress required (less than 500 Oc/fl) separated by ½ diagonal of floor, min. Two Accessible Means of Egress required (7.5.4.1). 48” clear stair width required (Accessible Means of Egress).
Chapter 8 - No Comment Chapter 9 - Elevator machine Room to be ventilated per 9.4.5.
Chapter 10 - No Comment Chapters 11- 41 – N/A Chapter 41 - Table 42.2.5: Max Dead End Corridor 50’, Common Path of Travel 50’, Table 42.8.2.6.1: Maximum Travel Distance to Exits 300’.
42.8.3.4.1(2): Fire Alarm System not required.
3. Uniform Federal Accessibility Standards, [V.A. Barrier Free Design Guide PG-18-13]
Chapter 4 - 4.1.1(5)(e)(iii) : 20% of all spaces to be Accessible Spaces in SCI facilities.
4.3: Accessible Route required from public transport, accessible spaces, Accessible loading zones, public sidewalks to building entrance. An Accessible Route to connect all accessible buildings and facilities on site.
Minimum Accessible Route width 36”[Modified by PG-18-13, page 1, to 60”] The VA has allowed the Design/Build Team a variation of PG-18-13 To “approximately 4’-0” at columns” – RFI D0006 Response, 08/16/2012, on file with Architect. In addition, Item 10, August 22, 2012 Letter from VA allows “encroachments every 22’ [to] narrow the accessible route to about 4’ wide for a two foot length…” 4.4.1: Protruding objects 27” to 80” AFF cannot project more than 4” into Walking surfaces.
4.4.2: 80” minimum headroom at walking surfaces.
4.6.3: Accessible Parking Spaces to be 96” wide min with one adjacent 60” Access Aisle [Modified by PG-18-13, page 2, to two 60” aisles]
The VA has Allowed the Design/Build Team a variation of PG-18-13 to accept Accessible Parking Spaces and Accessible SCI/PVA Parking Spaces with only one 60” Accessible Access Aisle where shear walls and columns interfere in the Plan provided to the Design/Build…