16104 ST PETERSBURG GRAVEL PARKING - FULL PLANSET.pdf
PDF 21 MB Posted
- Solicitation number
- 36C10E21R0003
About this file
This notice provides details for a federal contract opportunity to resurface parking lots at the Veterans Benefits Administration facility in St. Petersburg, Florida. The contract will be for firm-fixed price to resurface the north and south employee gravel parking lots with asphalt and new striping. Additional work will include new curbs, gutters, trees, and LED lighting on steel poles to reconfigure the lots and provide updated lighting. The performance period is 120 days from notice to proceed with a total estimated value between $1 million to $2 million. The solicitation number is 36C10E21R0003 and offers are due by April 30, 2021. This requirement has been set aside as a total small business service-disabled veteran-owned small business set-aside. The NAICS code is 237310 for highway, street, and bridge construction up to $39.5 million.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C10E21R0003 0004.docx | DOCX document | |
| Traffic Gate details.pdf | ||
| St. Petersburg Gravel Lots - FULL SPEC.pdf | ||
| Amendment 3 Questions - Answers.pdf | ||
| 36C10E21R0003 0003.docx | DOCX document | |
| 36C10E21R0003 0002.docx | DOCX document | |
| 36C10E21R0003_1.docx | DOCX document | |
| P09-STATEMENT OF WORK - FINAL 25Mar2021 DRM revisions.pdf | ||
| P01- SPECIFICATIONS ASPHALT PAVING.pdf | ||
| P01-Aerial View of area.pdf | ||
| General Decision Number FL20200139.pdf | ||
| P01-Bid Doc - BOD 1-29-21 w appendix.pdf | ||
| P01-Gravel lots Project Plans final.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s c o v e r d w g e d i t b f i e l s a v e d
A
M p o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
DEPARTMENT OF VETERANS AFFAIRS
ST. PETERSBURG GRAVEL PARKING
VA PROJECT NO. VB3238
CONSULTANTS
ANDERSON ENGINEERING OF MN, LLC
PROJECT MANAGEMENT, ARCHITECTURE, LANDSCAPE ARCHITECTURE,
PLANNING, ENVIRONMENTAL, CIVIL ENGINEERING, LAND SURVEY
13605 1ST AVENUE NORTH, SUITE 100
PLYMOUTH, MN 55441
CONTACT: ERIC SAUTBINE, PROJECT MANAGER
PHONE: (763) 412-4000
IMEG CORP.
STRUCTURAL ENGINEERING, MECHANICAL
ENGINEERING, ELECTRICAL ENGINEERING
14755 PRESTON ROAD; STE 845
DALLAS, TX 75254
CONTACT: MARIO ARREDONDO
PHONE: (972) 239-6100
CPMI
COST ESTIMATOR
3265 NORTHWOOD CIRCLE, SUITE 170
EAGAN, MN 55121
CONTACT: BRYAN BERTRAND
PHONE: (515) 697-1048
TERRACON
GEOTECHNICAL ENGINEER
6911 BLANCO ROAD
SAN ANTONIO, TX 78216
CONTACT: STEPHAN KNAUSS
PHONE: (813) 321-0326
VICINITY MAP LOCATION MAP
N.T.S.
N
N.T.S.
GI-001
COVER
ES BF
Sheet List Table
Sheet
Number
Sheet Title
GI-001 COVER
GC-001 CONSTRUCTION ACCESS
GC-002 PROJECT PHASING PLAN
V-100 EXISTING CONDITIONS SURVEY
CD-101 DEMOLITION PLAN - NORTH PARKING LOT
CD-102 DEMOLITION PLAN - SOUTH PARKING LOT
CS-101 SITE PLAN - NORTH PARKING LOT
CS-102 SITE PLAN - SOUTH PARKING LOT
CG-101 GRADING PLAN - NORTH PARKING LOT
CG-102 GRADING PLAN - SOUTH PARKING LOT
CE-101 EROSION CONTROL PLAN - NORTH PARKING LOT
CE-102 EROSION CONTROL PLAN - SOUTH PARKING LOT
CE-103 SWPPP NARRATIVE - PAGE 1
CE-104 SWPPP NARATIVE - PAGE 2
CU-101 UTILITY PLAN - NORTH PARKING LOT
CU-102 UTILITY PLAN - SOUTH PARKING LOT
C-501 CIVIL DETAILS 1
C-502 CIVIL DETAILS 2
LP-101 PLANTING PLAN - NORTH PARKING LOT
LP-102 PLANTING PLAN - SOUTH PARKING LOT
LP-501 LANDSCAPE DETAILS
E-000 ELECTRICAL COVERSHEET
E-101 SITE PLAN - NORTH - ELECTRICAL
E-102 SITE PLAN - SOUTH - ELECTRICAL
E-200 ELECTRICAL SCHEDULES AND DETAILS
N
PROJECT SITE
SITE LOCATION
SITE DATA
FL VBA REGIONAL OFFICE GROUNDS
9500 BAY PINES BLVD,
ST. PETERSBURG, FL 33744
COUNTY: PINELLAS
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text U
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s a c c e s s d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
GC-001
CONSTRUCTION ACCESS
ES BF
LEGEND
PHASE LIMITS
ROUTE OPTION A
ROUTE OPTION B
ROUTE DIRECTION
N
0 100' 200'
SCALE:
CONSTRUCTION ACCESS
1" = 100' (30" x 42" PAPER SIZE)
ROUTE OPTIONS
BAY PINES BLVD
H
O
O
V
E
R
B
L
V
D
H
O
O
V
V
D
T
H
S
T
C
E
M
E
T
E
Y
D
T
H
S
T
N
T
H
W
N
I L L
Y
O U
N G
H
I
G
H
W
D
LAKE TIMUCUAN
T
H
S
T
H
S
T
LOT 28
LOT 27
LOT 3
BRYSON CIR
B
I
O
U
N
G
HOOVER BLVD
B
P
I
N
V
P
O
L
I
C
E
S
T
A
T
I
O
N
VA ST. PETERSBURG
REGIONAL OFFICE
VA HOSPITAL BLDG
FISHER HOUSE
P
A
R
K
I
G
R
A
G
E
LAKE TIMUCUAN
EX. BASIN
GEN. PARKING
GEN. PARKING
NORTH LOT
SOUTH LOT
STOP LIGHT
INTERSECTION
STOP LIGHT
INTERSECTION
PHASE 1
PHASE 2
ROUTE A
ROUTE B
MAIN CAMPUS GATE
EAST GATE
PHASE 1
ACCESS
GENERAL NOTES
1. AREAS SHOWN OUTSIDE OF PHASE AREAS ARE
FOR CONCEPTUAL PURPOSES ONLY. ACCURACY
IS NOT GUARANTEED.
ROUTE A
ACCESS SITE FROM BAY PINES BLVD VIA EAST GATE
THROUGH HOOVER BLVD.
ROUTE B
ACCESS SITE FROM BAY PINES BLVD VIA MAIN
CAMPUS GATE THROUGH BILL YOUNG TO HOOVER
BLVD.
KEY NOTES
ACCESS TO PHASE 1 IS TO BE THROUGH WEST
SIDE OF SOUTH LOT. SEE PHASING PLAN FOR
MORE INFORMATION.
BAY PINES BLVD BAY PINES BLVD
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s p h a s i n g d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
LEGEND
PHASE LIMITS
PHASE STAGING AREA
PHASE 1 ACCESS ROUTE
CONSTRUCTION FENCE
SITE ACCESS POINT
TEMPORARY BARRIER
CONSTRUCTION SIGNAGE
N
0 50' 100'
SCALE:
PHASE 2 - SOUTH LOT
1" = 50' (30" x 42" PAPER SIZE)
GENERAL NOTES
1. AREAS SHOWN OUTSIDE OF PHASE AREAS ARE
SHOWN FOR CONCEPTUAL PURPOSES ONLY
AND IS NOT GUARANTEED IN ITS ACCURACY.
2. ALL TRAFFIC LANES TO BE KEPT OPEN.
3. CONTRACTOR RESPONSIBLE FOR ADDITIONAL
TRAFFIC CONTROL AS NECESSARY.
KEY NOTES
USE WEST LANE OF EXISTING PARKING LOT TO
GAIN ACCESS TO PHASE 1 - NORTH LOT
CONSTRUCT TEMPORARY ACCESS ROAD
CONSTRUCTION SITE ACCESS POINT
CONSTRUCT PHASE CONSTRUCTION FENCING.
SEE DETAIL 7/C-501
INSTALL TEMPORARY BARRIER (TYP.)
EMPLOYEE PARKING AREA TO REMAIN OPEN FOR
PHASE 1 OF CONSTRUCTION
TURN OVER NORTH EMPLOYEE PARKING LOT
PRIOR TO BEGINNING OF PHASE 2 - SOUTH LOT
N
0 50' 100'
SCALE:
PHASE 1 - NORTH LOT
1" = 50' (30" x 42" PAPER SIZE)
P
H
A
A
G
I
E
A
PHASE 1
GC-002
PROJECT PHASING PLAN
ES BF
PHASE 2
PHASE 2
STAGING
AREA
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
CONSTRUCTION
AHEAD
EX. BASIN
VA ST. PETERSBURG
REGIONAL OFFICE
BAY PINES VA
POLICE STATION
EX. BASIN
VA ST. PETERSBURG
REGIONAL OFFICE
BAY PINES VA
POLICE STATION
SIDEWALK
CLOSED
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g s u r v e y c a d f i l e s s b a s e d i t m t o l k k i n n v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21 V-100
EXISTING CONDITIONS
SURVEY
AutoCAD SHX Text
POINT NO. 10003
AutoCAD SHX Text
POINT NO. 1004
AutoCAD SHX Text
POINT NO. 10002
AutoCAD SHX Text
LANDSCAPE TIMBER
AutoCAD SHX Text
LANDSCAPE TIMBER
AutoCAD SHX Text
LANDSCAPE TIMBER
AutoCAD SHX Text
LANDSCAPE TIMBER
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
POINT NO. 1006
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
SPEED HUMP
AutoCAD SHX Text
POINT NO. 10000
AutoCAD SHX Text
BENCH MARK: TOP NUT OF HYDRANT ELEVATION = 10.46 FEET
AutoCAD SHX Text
POINT NO. 10005
AutoCAD SHX Text
HOOVER BLVD.
AutoCAD SHX Text
BLDG.
AutoCAD SHX Text
GATE
AutoCAD SHX Text
CONCRETE STRIP
AutoCAD SHX Text
CONCRETE SLAB
AutoCAD SHX Text
BAY PINES BLVD.
AutoCAD SHX Text
CULVERT
AutoCAD SHX Text
POWER POLE
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
LIGHT POLE
AutoCAD SHX Text
HYDRANT
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
GUARD POST
AutoCAD SHX Text W
AutoCAD SHX Text
EB
AutoCAD SHX Text E
AutoCAD SHX Text
ELECTRIC MANHOLE
AutoCAD SHX Text
SHRUB
AutoCAD SHX Text
HHE
AutoCAD SHX Text
HANDHOLE ELECTRIC
AutoCAD SHX Text
DECIDUOUS TREE
AutoCAD SHX Text
CONTROL POINT
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
ELECTRIC METER
AutoCAD SHX Text
SANITARY MANHOLE
AutoCAD SHX Text R
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
EM
AutoCAD SHX Text S
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
CO
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
CATCH BASIN
AutoCAD SHX Text
POWER POLE ANCHOR
AutoCAD SHX Text
IRRIGATION CONTROL VALVE
AutoCAD SHX Text H
AutoCAD SHX Text
HANDHOLE
AutoCAD SHX Text
OVERHEAD WIRES
AutoCAD SHX Text X
AutoCAD SHX Text
OHW
AutoCAD SHX Text
SANITARY SEWER
AutoCAD SHX Text
WATER MAIN
AutoCAD SHX Text
STORM SEWER
AutoCAD SHX Text
FENCE
AutoCAD SHX Text
UNDERGROUND ELECTRIC
AutoCAD SHX Text
UE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text I
AutoCAD SHX Text
COMMUNICATION
AutoCAD SHX Text
COMM
AutoCAD SHX Text
TEL
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
WATER MANHOLE
AutoCAD SHX Text W
AutoCAD SHX Text
WALL
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text The horizontal datum and bearings are based on the Florida State Plane Coordinate System, West zone NAD83 (2011).
AutoCAD SHX Text The vertical datum is NAVD 88. The site bench mark is the top nut of hydrant located south of Hoover Boulevard (depicted hereon). Elevation = 10.46 feet.
AutoCAD SHX Text 2.
AutoCAD SHX Text 1.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text The location and extent of underground utilities, if shown, are based upon existing drawings provided by the utility companies, above ground evidence and Sunshine 811 markings per ticket number 282006957. Exclusive of excavation, there is no guarantee as to the accuracy or the completeness of this information. The size and location should be considered approximate. Additional underground utilities may be present. Verification of the existence and location of all utilities should be obtained from the utility owners prior to any planning or design. In accordance with State Statute, the location of utilities shall be confirmed prior to any demolition or construction.
AutoCAD SHX Text 4.
AutoCAD SHX Text The tree information shown hereon was collected during the field survey by non-forestry trained Anderson Engineering of Minnesota survey personnel. Tree sizes are estimates and locations are accurate to plus or minus three feet.
AutoCAD SHX Text 5.
AutoCAD SHX Text
CONIFEROUS TREE
AutoCAD SHX Text
TREE LINE
AutoCAD SHX Text
UTILITY UNKNOWN
AutoCAD SHX Text
UT?
AutoCAD SHX Text
POINT NO.
AutoCAD SHX Text
NORTHING FL. SP. W.
AutoCAD SHX Text
EASTING FL. SP. W.
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
AutoCAD SHX Text 1265577.25
AutoCAD SHX Text 406081.48
AutoCAD SHX Text 8.96
AutoCAD SHX Text
SET 1/2 INCH REBAR PIPE
AutoCAD SHX Text 10005
AutoCAD SHX Text 1264859.21
AutoCAD SHX Text 406484.56
AutoCAD SHX Text 7.19
AutoCAD SHX Text
SET 1/2 INCH REBAR PIPE
AutoCAD SHX Text
AutoCAD SHX Text 1264822.64
AutoCAD SHX Text 406108.61
AutoCAD SHX Text 6.83
AutoCAD SHX Text
SET 1/2 INCH REBAR PIPE
AutoCAD SHX Text 10000
AutoCAD SHX Text 1264809.77
AutoCAD SHX Text 406311.27
AutoCAD SHX Text 7.81
AutoCAD SHX Text
SET 1/2 INCH REBAR PIPE
AutoCAD SHX Text 10002
AutoCAD SHX Text 1265688.86
AutoCAD SHX Text 406392.82
AutoCAD SHX Text 9.36
AutoCAD SHX Text
SET 1/2 INCH REBAR PIPE
AutoCAD SHX Text 10003
AutoCAD SHX Text 1265697.42
AutoCAD SHX Text 406162.78
AutoCAD SHX Text 9.44
SET 1/2 INCH REBAR PIPE
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s d e m o l i t i o n n o r t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CD-101
DEMOLITION PLAN - NORTH
PARKING LOT
ES BF
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
FULL DEPTH SAWCUT
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING UNDERGROUND ELECTRIC
UNIDENTIFIED UNDERGROUND UTILITY
REMOVE EXISTING CONCRETE C&G
REMOVE EXISTING ASPHALT PAVEMENT
REMOVE EXISTING TREE
TREE PROTECTION
EXISTING ELECTRIC HANDHOLES
EXISTING IRRIGATION VALVE
LEGEND
N
0 10' 20'
SCALE:
DEMOLITION PLAN - NORTH PARKING LOT
1" = 10' (30" x 42" PAPER SIZE)
GENERAL NOTES:
1. CONTRACTOR RESPONSIBLE FOR SECURING WORK
AREA. CONSTRUCTION FENCING TO BE INSTALLED
AROUND WORK SITE. FENCING TO HAVE VISUAL
BARRIER IN AREAS NEAR PUBLIC. FENCING TO BE
APPROVED BY R.E.
2. CONTRACTOR TO FIELD VERIFY UTILITIES PRIOR TO
WORK.
3. MAINTAIN PROPER STORMWATER DRAINAGE
THROUGHOUT CONSTRUCTION.
KEY NOTES:
PROTECT EXISTING LIGHT POLE IN-PLACE
PROTECT EXISTING UNDERGROUND POWER UNLESS
DIRECTED OTHERWISE ON ELECTRICAL PLAN
FULL DEPTH SAWCUT
REMOVE AND PROPERLY DISPOSE OF TREATED
TIMBER (TYP.)
REMOVE BALLARDS AND CHAINS (TYP.)
REMOVE EXISTING BUMPER CURBS (TYP.)
REMOVE EXISTING CONCRETE CURB AND GUTTER
INSTALL TREE PROTECTION (TYP.) SEE DETAIL 4/C-501
REMOVE EXISTING SIGNAGE
STRIP AND CLEAR EXISTING GRAVEL
CONSTRUCTION LIMITS
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BAY PINES BLVD.
HHE
CONSTRUCTION LIMITS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s d e m o l i t i o n s o u t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CD-102
DEMOLITION PLAN - SOUTH
PARKING LOT
ES BF
N
0 20' 40'
SCALE:
DEMOLITION PLAN - SOUTH PARKING LOT
1" = 20' (30" x 42" PAPER SIZE)
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
FULL DEPTH SAWCUT
REMOVE EXISTING UTILITY
REMOVE EXISTING CONC. WALK
SITE LIMITS
GRAVEL PARKING EXTENTS
EXISTING SANITARY SEWER
EXISTING UNDERGROUND ELECTRIC
EXISTING STORM SEWER
EXISTING UNDERGROUND
COMMUNICATION
EXISTING UNIDENTIFIED UTILITY
REMOVE EXISTING CONCRETE C&G
REMOVE EXISTING TREE
TREE PROTECTION
EXISTING ELECTRIC HANDHOLES
EXISTING STORM SEWER INLET
EXISTING ELECTRIC MANHOLE
EXISTING SANITARY MANHOLE
EXISTING CLEANOUT
LEGEND
KEY NOTES:
PROTECT EXISTING LIGHT POLE IN-PLACE
FULL DEPTH SAWCUT
REMOVE AND PROPERLY DISPOSE OF TREATED
TIMBER (TYP.)
REMOVE BALLARDS AND CHAINS (TYP.)
REMOVE EXISTING BUMPER CURBS (TYP.)
REMOVE EXISTING CONCRETE CURB AND GUTTER
INSTALL TREE PROTECTION (TYP.) SEE DETAIL
4/C-501
REMOVE EXISTING SIGNAGE
STRIP & CLEAR EXISTING GRAVEL
REMOVE EXISTING STORM CULVERT
REMOVE EXISTING CONC. WALK
CONCRETE PAD TO REMAIN IN-PLACE
PROTECT EXISTING CONCRETE WALK TO REMAIN
ADJUST MANHOLE RIM TO FINISHED GRADE
PROTECT EXISTING SANITARY SEWER IN-PLACE.
FIELD LOCATE SANITARY SEWER PRIOR TO
BEGINNING CONSTRUCTION
PROTECT EXISTING UNDERGROUND POWER
UNLESS DIRECTED OTHERWISE ON ELECTRICAL
PLAN (TYP.)
REMOVE AND DISPOSE OF EXISTING LIGHT POLE
REMOVE UNDERGROUND UTILITIES. SEE
ELECTRICAL PLAN
GENERAL NOTES
1. CONTRACTOR RESPONSIBLE FOR SECURING
WORK AREA. CONSTRUCTION FENCING TO BE
INSTALLED AROUND WORK SITE. FENCING TO HAVE
VISUAL BARRIER IN AREAS NEAR PUBLIC. FENCING
TO BE APPROVED BY R.E.
2. CONTRACTOR TO FIELD VERIFY UTILITIES PRIOR
TO WORK.
3. MAINTAIN PROPER STORMWATER DRAINAGE
THROUGHOUT CONSTRUCTION.
7TYP.
3TYP.
4TYP.
3TYP.
5 TYP.
3TYP.
4TYP.
16 TYP.
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
SPEED HUMP
AutoCAD SHX Text
BENCH MARK: TOP NUT OF HYDRANT ELEVATION = 10.46 FEET
AutoCAD SHX Text
HOOVER BLVD.
AutoCAD SHX Text
BLDG.
AutoCAD SHX Text
GATE
AutoCAD SHX Text
CONCRETE STRIP
AutoCAD SHX Text
CONCRETE SLAB
HHE
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s s i t e p l a n n o r t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CS-101
SITE PLAN - NORTH
PARKING LOT
ES BF
KEYNOTES
CONSTRUCTION LIMITS
INSTALL VERTICAL CONCRETE C&G
INSTALL FLUSH CONCRETE C&G
INSTALL BITUMINOUS PAVEMENT
INSTALL CONCRETE
PAVEMENT
NO PARKING ZONE
NUMBER OF PARKING STALLS IN
SECTION
TRAFFIC DIRECTION ARROW
NEW BUMPER CURB
NEW SIGN
NEW LIGHT
CONTRACTOR NOTES
1. ALL RADIUS SHOWN ARE TO FACE OF CURB
N
0 10' 20'
SCALE:
SITE PLAN - NORTH PARKING LOT
1" = 10' (30" x 42" PAPER SIZE)
LEGEND
B B
8.0'
B-B
240.1'
B B
INSTALL VERTICAL CONCRETE CURB. SEE DETAIL
9/C-501
4" WIDE WHITE PAVEMENT MARKINGS (TYP.)
MATCH EXISTING CURB AND GUTTER
INSTALL FLUSH CONCRETE CURB. SEE DETAIL
10/C-501
MATCH EXISTING PAVEMENT
ONE WAY ONLY SIGN. SEE DETAIL 4/C-502
DO NOT ENTER SIGN. SEE DETAIL 5/C-502
INSTALL NEW BUMPER CURB (TYP.) SEE DETAIL
7/C-502
NEW LIGHT. SEE ELECTRICAL (TYP.)
3' CURB TAPER FROM VERTICAL CURB TO FLUSH
CURB
18.0'
F-F
8.0'
B-B
R
211.2'
B-B
R
R
R
R
18.0'
F-F
R
PARKING COUNT
EXISTING STALLS: 52 (9'x18')
NEW STALLS: 41 (9'x18')
B B
CONSTRUCTION LIMITS
R
R
R
R
TYP.
TYP.
TYP.
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
BAY PINES BLVD.
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s s i t e p l a n s o u t h d i t m t o l k k i n v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CS-102
SITE PLAN - SOUTH
PARKING LOT
ES BF
CONTRACTOR NOTES
1. ALL RADIUS SHOWN ARE TO FACE OF CURB
N
0 20' 40'
SCALE:
SITE PLAN - SOUTH PARKING LOT
1" = 20' (30" x 42" PAPER SIZE)
KEYNOTES
CONSTRUCTION LIMITS
INSTALL CONCRETE C&G
INSTALL BITUMINOUS
PAVEMENT
INSTALL CONCRETE
PAVEMENT
NO PARKING ZONE
NUMBER OF PARKING STALLS IN
SECTION
TRAFFIC DIRECTION ARROW
NEW SIGN
NEW LIGHT
NEW STORM STRUCTURES
LEGEND
INSTALL VERTICAL CONCRETE CURB. SEE DETAIL
9/C-501
4" WIDE WHITE PAVEMENT MARKINGS (TYP.)
MATCH EXISTING CURB AND GUTTER
INSTALL NEW BUMPER CURB (TYP.) SEE DETAIL
7/C-502
MATCH EXISTING PAVEMENT
ONE WAY ONLY SIGN. SEE DETAIL 4/C-502
DO NOT ENTER SIGN. SEE DETAIL 5/C-502
INSTALL CONCRETE SIDEWALK. SEE DETAIL
5/C-501
NEW LIGHT. SEE ELECTRICAL (TYP.)
B
B
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
F F
F
F
F
F
B
B
B
B
.0
B B
B
B
B
B
EXISTING STALLS: 140 (9'x18')
NEW STALLS: 108 (9'x18')
F
F
ELECTRONIC GATE
SEE ELECTRICAL
R
R
R
R
R
R
R
R
R
PARKING COUNT
TYP.
TYP.
R
R
R
R
R
R
CONSTRUCTION
LIMITS (TYP.)
AutoCAD SHX Text
SPEED HUMP
AutoCAD SHX Text
HOOVER BLVD.
AutoCAD SHX Text
GATE
CONCRETE SLAB
TC 10.79
FL 10.29
TC 10.46
FL 9.96
10.41±
TC 10.63
FL 10.13
TC 10.58
FL 10.08
TC 10.65
FL 10.15
10.02±
EC 9.18
FL 9.30
TC 10.89
FL 10.39
TC 11.00
FL 10.50
TC 10.65
FL 10.15
TC 10.57
FL 10.07
TC 10.79
FL 10.29
TC 11.00
FL 10.50
TC 10.62
FL 10.12
TC 10.67
FL 10.17
TC 10.25
FL 9.75
TC 10.21
FL 9.71
TC 10.17
FL 9.67
9.81±
TC 11.00
FL 10.50
TC 10.22
FL 9.72
EC 9.18
FL 9.30
10.47±
TC 10.99
FL 10.49
TC 10.72
FL 10.22
TC 10.58
FL 10.08
TC 10.72
FL 10.22
TC 11.00
FL 10.50
TC 10.64
FL 10.14
TC 10.50
FL 10.00
TC 10.57
FL 10.07
TC 10.79
FL 10.29
TC 10.79
FL 10.29
TC 10.50
FL 10.00
9.91±
9.78±
9.88±
9.94±
EC 9.18
FL 9.30
TC 10.71
FL 10.21
CG-101
GRADING PLAN - NORTH
PARKING LOT
ES BF
LEGEND
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
DRAINAGE ARROW
VERTICAL CONCRETE CURB
FLUSH CONCRETE CURB
RIDGE LINE
NEW LIGHT
SPOT ELEVATION LEGEND
9.06 ±
FL 10.16
TC 10.31
MATCH EXISTING
FLOW LINE
TOP OF CURB
FINISHED GRADE
HIGH POINT
EDGE OF CURB
KEY NOTES
2.0%
HP 9.75
N
0 10' 20'
SCALE:
GRADING PLAN - NORTH PARKING LOT
1" = 10' (30" x 42" PAPER SIZE)
INSTALL VERTICAL CONCRETE CURB. SEE DETAIL
9/C-501
INSTALL FLUSH CONCRETE CURB. SEE DETAIL
10/C-501
RIDGE
RIDGE
FLUSH CONCRETE CURB & GUTTER
CONSTRUCTION LIMITS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s g r a d i n g n o r t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
EXISTING SWALE
EOF AT
ELEV = 8.70±
MATCH EXISTING
PAVEMENT GRADE LINE
MATCH EXISTING
PAVEMENT GRADE LINE
T Y
P
T Y
P
FG 10.16
EC 9.75
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
7.54±
7.50±
7.64±
7.50±
9.92± 10.15±
9.74±
10.17±
I 4.40
I 6.30
I 5.70
I 5.9
FG 10.8
TC 10.4
FL 9.9
TC 10.0
FL 9.5
R 9.4
TC 10.2
FL 9.7
TC 10.2
FL 9.7
TC 10.0
FL 9.5
TC 10.0
FL 9.5
R 9.2
TC 10.0
FL 9.5
R 9.2
TC 10.0
FL 9.5
TC 10.2
FL 9.7
TC 10.2
FL 9.7
TC 10.3
FL 9.8
TC 10.5
FL 10.0
TC 10.7
FL 10.2
TC 10.5
FL 10.0
TC 10.5
FL 10.0
TC 10.5
FL 10.0
TC 10.5
FL 10.0
TC 10.5
FL 10.0
TC 10.2
FL 9.7
TC 9.7
FL 9.2
TC 10.0
FL 9.5
7.8±
TC 10.5
FL 10.0
FG 10.8
FG 10.7
TC 9.5
FL 9.0
TC 9.0
FL 8.5
TC 8.7
FL 8.2
TC 8.25
FL 7.75
TC 8.5
FL 8.0
LP 7.5
TC 8.7
FL 8.2
FG 8.4
TC 9.1
FL 8.6
TC 9.1
FL 8.6
TC 9.2
FL 8.7
TC 9.3
FL 8.8
TC 9.4
FL 8.9
LP 7.4
TC 8.5
FL 8.0
TC 8.5
FL 8.0
TC 8.1
FL 7.6
TC 8.8
FL 8.3
TC 8.9
FL 8.4
TC 9.1
FL 8.6
TC 9.0
FL 8.5
TC 9.2
FL 8.7
TC 9.0
FL 9.5
TC 10.5
FL 10.0
TC 9.2
FL 8.7
TC 8.8
FL 8.3
TC 8.9
FL 8.4
TC 9.8
FL 9.3
FG 9.9
R 8.7
TC 9.25
FL 8.75
TC 9.4
FL 8.9
TC 8.5
FL 8.0
I 6.2
TC 8.5
FL 8.0
TC 8.5
FL 8.0
I 5.7
FG 9.15
I 9.75
R 10.16
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s g r a d i n g s o u t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CG-102
GRADING PLAN - SOUTH
PARKING LOT
ES BF
LEGEND
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
DRAINAGE ARROW
CONCRETE VERTICAL CURB
STORM STRUCTURES
FES STRUCTURE
RIDGE LINE
RIP-RAP
NEW LIGHT
SPOT ELEVATION LEGEND
GENERAL NOTES
1. CURB CUTS SHALL HAVE 8" TRANSITION
FROM FULL HEIGHT TO FLOW LINE.
2. ALL SIDEWALK CROSS SLOPES SHALL
BE 2.0% MAX.
2.0%
N
0 20' 40'
SCALE:
GRADING PLAN - SOUTH PARKING LOT
1" = 20' (30" x 42" PAPER SIZE)
CONSTRUCTION
LIMITS
KEYNOTES
INSTALL 3' WIDE CURB CUT WITH RIP-RAP.
SEE DETAIL 6/C-502
ADJUST EXISTING RIM ELEVATION TO
FINISHED GRADE
INSTALL VERTICAL CONCRETE CURB. SEE
DETAIL 9/C-501
MATCH EXISTING
PAVEMENT GRADE LINE
MATCH EXISTING
PAVEMENT GRADE LINE
MATCH EXISTING
PAVEMENT GRADE LINE
MATCH EXISTING
PAVEMENT GRADE LINE
9.06 ±
FL 10.16
TC 10.31
MATCH EXISTING
FLOW LINE
TOP OF CURB
FINISHED GRADE
HIGH POINT
RIM
INVERT
HP 9.75
FG 10.16
TYP.
BOTTOM = 4.3
SEE 3/C-502 FOR
PED RAMP
GRADING DETAIL
R
I D
G
E
R
I D
G
E
R
I D
G
E
R
I D
G
E
8.2
RIDG
E
.0
1.4%
T
Y
P
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
SPEED HUMP
AutoCAD SHX Text
BENCH MARK: TOP NUT OF HYDRANT ELEVATION = 10.46 FEET
AutoCAD SHX Text
HOOVER BLVD.
AutoCAD SHX Text
BLDG.
AutoCAD SHX Text
GATE
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s e r o s i o n c o n t r o l n o r t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CE-101
EROSION CONTROL PLAN -
NORTH PARKING LOT
ES BF
N
0 10' 20'
SCALE:
EROSION CONTROL PLAN - NORTH PARKING LOT
1" = 10' (30" x 42" PAPER SIZE)
LEGEND
KEY NOTES:
INSTALL & MAINTAIN EROSION CONTROL FENCE IN
GRASSED AREAS. SEE DETAIL 1/C-501
INSTALL AND MAINTAIN BIO-ROLLS IN PAVED AREAS
IF ENTRANCE IS NOT BEING USED. SEE DETAIL
3/C-501
INSTALL & MAINTAIN INLET SEDIMENT PROTECTION.
SEE DETAIL 2/C-501
INSTALL TEMPORARY ROCK ENTRANCE AT
CONSTRUCTION EGRESS LOCATION(S), (MIN 1). SEE
DETAIL 8/C-501
INSTALL AND MAINTAIN DITCH CHECK. SEE DETAIL
6/C-501
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
NEW MINOR CONTOUR
NEW MAJOR CONTOUR
DRAINAGE ARROW
SILT FENCE (GRASSED AREAS)
BIO-ROLL (PAVED AREAS)
INLET PROTECTION
DITCH CHECK
ROCK CONSTRUCTION ENTRANCE
CONSTRUCTION LIMITS
DISCHARGE POINT
AutoCAD SHX Text
BUMPER CURB
BUMPER CURB
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s e r o s i o n c o n t r o l s o u t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CE-102
EROSION CONTROL PLAN
- SOUTH PARKING LOT
ES BF
N
0 20' 40'
SCALE:
EROSION CONTROL PLAN - SOUTH PARKING LOT
1" = 20' (30" x 42" PAPER SIZE)
LEGEND
KEY NOTES:
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
NEW MINOR CONTOUR
NEW MAJOR CONTOUR
DRAINAGE ARROW
SILT FENCE (GRASSED AREAS)
BIO-ROLL (PAVED AREAS)
INLET PROTECTION
DITCH CHECK
ROCK CONSTRUCTION ENTRANCE
INSTALL EROSION CONTROL BLANKET
INSTALL & MAINTAIN EROSION CONTROL FENCE IN
GRASSED AREAS. SEE DETAIL 1/C-501
INSTALL AND MAINTAIN BIO-ROLLS IN PAVED AREAS
IF ENTRANCE IS NOT BEING USED. SEE DETAIL
3/C-501
INSTALL & MAINTAIN INLET SEDIMENT PROTECTION.
SEE DETAIL 2/C-501
INSTALL TEMPORARY ROCK ENTRANCE AT
CONSTRUCTION EGRESS LOCATION(S), (MIN 1). SEE
DETAIL 8/C-501
INSTALL AND MAINTAIN DITCH CHECK. SEE DETAIL
6/C-501
3' WIDE CURB CUT WITH RIP-RAP. SEE DETAIL
7/C-502
INSTALL EROSION CONTROL BLANKET WITHIN
SLOPES 3:1 OR STEEPER AND WITHIN DRAINAGE
SWALES
RIP-RAP AT FLARED END SECTION. SEE DETAIL
2/C-502
AutoCAD SHX Text
SPEED HUMP
AutoCAD SHX Text
BENCH MARK: TOP NUT OF HYDRANT ELEVATION = 10.46 FEET
AutoCAD SHX Text
HOOVER BLVD.
AutoCAD SHX Text
BLDG.
AutoCAD SHX Text
GATE
STORM WATER POLLUTION PREVENTION PLAN NARRATIVE - PAGE 1 OF 2
THE FOLLOWING NARRATIVE OF THE STORMWATER POLLUTION PREVENTION PLAN DURING CONSTRUCTION. SPECIFICATION
SECTION 104, AND REPORTS OF INSPECTIONS MADE CONTRACTOR'S APPROVED EROSION CONTROL PLAN REQUIRED BY
DESCRIPTION, THE DOCUMENTS REFERENCED IN THIS NARRATIVE, THE PREVENTION PLAN INCLUDES SEVERAL ITEMS: THIS
NARRATIVE TO THE OTHER SHEETS. THE COMPLETE STORMWATER POLLUTION CONSTRUCTION PLANS (CALLED THE KEY
SHEET) CONTAINS AN INDEX OF THESE CONSTRUCTION PLANS. THE FIRST SHEET OF THE AND BRIDGE CONSTRUCTION, THE
DESIGN STANDARDS, AND OTHER SHEETS PLAN CONTAINS REFERENCES TO THE STANDARD SPECIFICATIONS FOR ROAD
1.0 SITE DESCRIPTION: THE PROJECT SITE IS LOCATED AT THE FLORIDA VBA REGIONAL OFFICE GROUNDS AT 9500 BAY PINES
BLVD, ST. PETERSBURG, FL 33744 IN PINELLAS COUNTY, FLORIDA. THE SITE IS BOUNDED TO THE NORTH BY BAY PINES
BOULEVARD, AND THE SOUTH BY HOOVER BOULEVARD.
1.A. NATURE OF CONSTRUCTION ACTIVITY:
THE PROJECT IS THE RENOVATION OF THE EXISTING GRAVEL PARKING LOTS THAT CURRENTLY SERVES VA EMPLOYEES. THIS
WILL INVOLVE DEMOLITION OF THE EXISTING PARKING LOTS AND ASSOCIATED STRUCTURES, AND CONSTRUCTION OF NEW
CONCRETE CURB AND GUTTERS, ASPHALT PAVING, SIDEWALKS, UNDERGROUND STORM DRAIN SYSTEMS, SUPPLEMENTARY
LIGHTING AND THE ADDITION OF TWO ACCESS POINTS ON THE NORTH SIDE OF THE SOUTH PARKING LOT.
1.B. SEQUENCE OF MAJOR SOIL DISTURBING ACTIVITIES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL PROVIDE A DETAILED SEQUENCE OF
CONSTRUCTION FOR ALL CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL FOLLOW THE SEQUENCE OF MAJOR
ACTIVITIES DESCRIBED BELOW, UNLESS THE CONTRACTOR PROPOSES A DIFFERENT SEQUENCE THAT IS EQUAL OR BETTER
AT CONTROLLING EROSION AND TRAPPING SEDIMENT AND IS APPROVED BY THE ENGINEER.
FOR EACH CONSTRUCTION PHASE, INSTALL PERIMETER CONTROLS AFTER CLEARING AND GRUBBING NECESSARY FOR
INSTALLATION OF CONTROLS BUT BEFORE BEGINNING OTHER WORK FOR THE CONSTRUCTION PHASE. REMOVE PERIMETER
CONTROLS ONLY AFTER ALL UPSTREAM AREAS ARE STABILIZED.
1. CLEARING AND GRUBBING, EARTHWORK, AND STORM DRAIN CONSTRUCTION FOR THE OUTFALL FROM THE PONDS.
2. CLEARING AND GRUBBING, EARTHWORK FOR POND CONSTRUCTION.
3. STORM DRAIN AND ROADWAY UNDERDRAIN CONSTRUCTION. CONSTRUCT THE STORM DRAIN PIPE IN THE UPSTREAM
DIRECTION.
4. EARTHWORK ASSOCIATED WITH THE CONSTRUCTION OF ROADWAY, GRAVITY WALL, CURB, SUBGRADE, BASE, PAVEMENT, AND SIDEWALK.
5. CONSTRUCT UNDERDRAIN IN POND BOTTOM.
1.C. AREA ESTIMATES:
TOTAL SITE AREA: 19.6 ACRES.
TOTAL AREA TO BE DISTURBED: 19.6 ACRES.
1.D. RUNOFF DATA:
RUNOFF COEFFICIENTS:
BEFORE: 0.62
DURING: VARIES FROM 0.62 TO 0.76
AFTER: 0.76
SOILS DATA: THE RESULTS OF THE SOIL BORINGS TAKEN AT THE PROJECT SITE CAN BE FOUND IN THE GEOTECHNICAL
REPORT COMPILED BY TERRACON CONSULTANTS ON NOVEMBER 18TH, 2020. SOIL TYPES FOUND ON SITE ARE TYPICALLY
POORLY GRADED SAND WITH SILT (SP-SM) AND GRAVEL (GM) WITH SILT (FILL).
OUTFALL INFORMATION:
THERE ARE 2 EXISTING OUTFALLS.
#1 DESCRIPTION: EXISTING OUTFALL AT NORTH PARKING LOT.
LOCATION: LATITUDE 27° 48' 48.76"N, LONGITUDE, -082° 46' 24.91"W.
EST. DRAINAGE AREA SIZE: 0.89 ACRES.
RECEIVING WATER NAME: NOT APPLICABLE.
#2 DESCRIPTION: PROPOSED OUTFALL AT FES AT SOUTH PARKING LOT.
LOCATION: LATITUDE 27° 48' 42.12"N, LONGITUDE -082° 46' 24.34"W.
EST. DRAINAGE AREA SIZE: 1.82 ACRES.
RECEIVING WATER NAME: NOT APPLICABLE.
1.E. SITE MAP:
THE CONSTRUCTION PLANS ARE BEING USED AS THE SITE MAPS. THE LOCATION OF THE REQUIRED INFORMATION IS
DESCRIBED BELOW. THE SHEET NUMBERS FOR THE PLAN SHEETS REFERENCED ARE IDENTIFIED ON THE KEY SHEET OF
THESE CONSTRUCTION PLANS.
* DRAINAGE PATTERNS: THE DRAINAGE BASIN DIVIDES AND FLOW DIRECTIONS ARE SHOWN ON THE DRAINAGE MAPS. THE
BACK OF SIDEWALK PROFILE SHEETS SHOW OVERLAND FLOW DIRECTION AT THE RIGHT OF WAY LINE. THE ARROWS ABOVE
AND BELOW THE PROFILE REPRESENT THE FLOW DIRECTION AT THE LEFT AND RIGHT PROPERTY LINE, RESPECTIVELY.
ARROWS POINTING TO THE PROFILE INDICATE RUNOFF COMING TO THE SITE. POINTING AWAY FROM THE SITE INDICATE
RUNOFF LEAVING THE SITE.
* APPROXIMATE SLOPES: THE SLOPES OF THE SITE CAN BE SEEN IN THE GRADING SHEETS.
AREAS OF SOIL DISTURBANCE: THE AREAS TO BE DISTURBED ARE INDICATED ON THE GRADING SHEETS.
* AREAS NOT TO BE DISTURBED: ESSENTIALLY THE WHOLE PROJECT WILL BE DISTURBED DURING CONSTRUCTION.
LOCATIONS OF TEMPORARY CONTROLS: THESE ARE SHOWN ON THE EROSION CONTROL SHEETS.
* LOCATIONS OF PERMANENT CONTROLS: THE STORMWATER CONVEYANCE SYSTEM IS THE PRIMARY PERMANENT
STORMWATER MANAGEMENT CONTROLS. THESE ARE SHOWN ON THE SOUTH PARKING LOT UTILITY SHEET.
SURFACE WATERS:
* DISCHARGE POINTS TO SURFACE WATERS:
1.F. RECEIVING WATERS:
SEE ITEM 1.D FOR THE OUTFALL LOCATIONS AND RECEIVING WATER NAMES. THERE ARE NO WETLAND AREAS ON THE
PROJECT SITE.
2.0 CONTROLS:
2.A. EROSION AND SEDIMENT CONTROLS:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL DESCRIBE THE PROPOSED STABILIZATION AND
STRUCTURAL PRACTICES BASED ON THE CONTRACTOR'S PROPOSED TEMPORARY TRAFFIC CONTROL (TTC) PLAN. THE FOLLOWING
RECOMMENDED GUIDELINES ARE BASED ON THE TEMPORARY TRAFFIC CONTROL PLAN OUTLINED IN THE CONSTRUCTION PLANS.
WHERE FOLLOWING THE TEMPORARY TRAFFIC CONTROL PLAN OUTLINED IN THESE CONSTRUCTION PLANS, THE CONTRACTOR MAY
CHOOSE TO ACCEPT THE FOLLOWING GUIDELINES OR MODIFY THEM IN THE SEDIMENT AND EROSION CONTROL PLAN, SUBJECT TO
APPROVAL BY THE ENGINEER. AS WORK PROGRESSES, THE CONTRACTOR SHALL MODIFY THE PLAN TO ADAPT TO SEASONAL
VARIATIONS, CHANGES IN CONSTRUCTION ACTIVITIES, AND THE NEED FOR BETTER PRACTICES.
FOR EACH CONSTRUCTION PHASE, INSTALL PERIMETER CONTROLS AFTER CLEARING AND GRUBBING NECESSARY FOR INSTALLATION
OF CONTROLS BUT BEFORE BEGINNING OTHER WORK FOR THE CONSTRUCTION PHASE. REMOVE PERIMETER CONTROLS ONLY
AFTER ALL UPSTREAM AREAS ARE STABILIZED.
PHASE I OF TEMPORARY TRAFFIC CONTROL PLANS.
ROADWAY, STATION 501+10 TO 520+40 RIGHT: IMMEDIATELY AFTER CONSTRUCTING THE TEMPORARY PAVEMENT, STABILIZE THE
ENTIRE AREA BETWEEN THE TEMPORARY PAVEMENT AND THE RIGHT OF WAY LINE USING TEMPORARY SOD.
OUTFALL OF POND 1:
CONSTRUCT THE OUTFALL PIPE FROM S-106 TOWARDS THE POND. THE CONTRACTOR SHALL HAVE INLET PROTECTION AVAILABLE AT
ALL TIMES
DURING THE PIPE CONSTRUCTION TO SUBSTANTIALLY BLOCK RUNOFF
IN THE TRENCH FROM ENTERING THE PIPE. CONSTRUCT PIPE TO THE
POND AND CONSTRUCT THE OUTLET STRUCTURE OF THE POND.
POND 1 CONSTRUCTION:
CLEAR AND GRUB THE POND SITE. INITIALLY EXCAVATE THE POND ENOUGH TO CONSTRUCT SEDIMENT BARRIERS AS DETAILED IN
THE TTC PLAN. THEN EXCAVATE THE POND TO APPROXIMATE PROPOSED DIMENSIONS. TURF ALL DISTURBED AREAS OF THE POND
SITE ABOVE ELEVATION 51.0. FINAL GRADING WILL BE DONE AT THE END OF PHASE TWO OF THE TTC PLAN.
ROADWAY, STATION 510+10 TO 523+70 LEFT:
PHASE II OF THE TEMPORARY TRAFFIC CONTROL PLAN:
ROADWAY, STATION 510+10 TO 523+10 RIGHT:
DURING THE SUBSOIL EXCAVATION AND CONSTRUCTION OF THE ROADWAY UNDERDRAIN AND STORM DRAIN, USE S-20 AS
THE PRIMARY INLET FOR CONVEYANCE TO POND 1. STAGE CONSTRUCTION AND PROTECT THE INLET IN A MANNER SIMILAR
TO S-19 IN PHASE I OF THE TTC PLAN.
ROADWAY, STATION 501+10 TO 510+40 RIGHT:
DURING THE SUBSOIL EXCAVATION AND CONSTRUCTION OF THE UNDERDRAIN, STORM DRAIN, AND WALLS, USE S-10 AS THE
PRIMARY INLET FOR CONVEYANCE TO THE LAURA LEE POND. STAGE CONSTRUCTION AND PROTECT THE INLET IN A MANNER
SIMILAR TO S-12 IN PHASE I OF THE TTC PLAN.
POND 1 CONSTRUCTION:
AFTER ENTIRE BASIN IS PERMANENTLY STABILIZED, CONSTRUCT UNDERDRAIN IN THE POND BOTTOM.
2.A.1 STABILIZATION PRACTICES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL DESCRIBE THE STABILIZATION PRACTICES
PROPOSED TO CONTROL EROSION. THE CONTRACTOR SHALL INITIATE ALL STABILIZATION MEASURES AS SOON AS
PRACTICAL, BUT IN NO CASE MORE THAN 7 DAYS AFTER CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY
CEASED. THE STABILIZATION PRACTICES SHALL INCLUDE AT LEAST THE FOLLOWING, UNLESS OTHERWISE APPROVED BY THE
ENGINEER.
TEMPORARY:
* ARTIFICIAL COVERINGS IN ACCORDANCE WITH SPECIFICATION SECTION 104.
* TURF AND SOD IN ACCORDANCE WITH SPECIFICATION SECTION 104.
PERMANENT:
* ASPHALT OR CONCRETE SURFACE.
* SOD IN ACCORDANCE WITH SPECIFICATION SECTION 570.
CONSTRUCT THE STORM DRAIN FROM THE POND TO THE ROADWAY AND THEN IN THE UPSTREAM DIRECTION ALONG THE LEFT SIDE
OF THE PROJECT. DURING THE SUBSOIL EXCAVATION, AND CONSTRUCTION OF THE ROADWAY UNDERDRAIN, STORM DRAIN, AND
WALL, USE S-19 AS THE PRIMARY INLET FOR CONVEYANCE TO THE POND. STAGE CONSTRUCTION OF THE INLET AS DETAILED IN THE
TTC PLAN.
ROADWAY, STATION 501+10 TO 510+40 LEFT:
DURING THE SUBSOIL EXCAVATION ,AND CONSTRUCTION OF THE UNDERDRAIN, STORM DRAIN, AND WALL, USE S-12 AS THE PRIMARY
INLET FOR CONVEYANCE TO THE LAURA LEE POND. S-12 SHOULD BE CONSTRUCTED BEFORE DISTURBING SOIL UPSTREAM. STAGE
CONSTRUCTON AND PROTECT THE INLET AS DETAILED IN THE TTC PLAN.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s s w p p p d i t m t o l k k i n v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CE-103
SWPPP NARRATIVE - PAGE 1
ES BF
STORM WATER POLLUTION PREVENTION PLAN NARRATIVE - PAGE 2 OR 2
2.A.2 STRUCTURAL PRACTICES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL
DESCRIBE THE PROPOSED STRUCTURAL PRACTICES TO CONTROL OR TRAP SEDIMENT AND OTHERWISE PREVENT THE
DISCHARGE OF POLLUTANTS FROM EXPOSED AREAS OF THE SITE. SEDIMENT CONTROLS SHALL BE IN PLACE BEFORE
DISTURBING SOIL UPSTREAM OF THE CONTROL. THE STRUCTURAL PRACTICES SHALL INCLUDE AT LEAST THE FOLLOWING, UNLESS OTHERWISE APPROVED BY THE ENGINEER:
TEMPORARY:
* SEDIMENT BARRIERS IN ACCORDANCE WITH DESIGN SPECIFICATION SECTION 104, AND FDEP EROSION AND SEDIMENT
CONTROL DESIGNER AND REVIEWER MANUAL.
* INLET PROTECTION IN ACCORDANCE WITH FDEP EROSION AND SEDIMENT CONTROL DESIGNER AND REVIEWER MANUAL, AND SPECIAL DETAILS SHOWN IN THE TTC PLAN.
* SEDIMENT CONTAINMENT SYSTEM:
PERMANENT:
* SOD.
* STORMWATER PONDS.
2.B STORMWATER MANAGEMENT:
A STORM DRAIN SYSTEM WILL BE CONSTRUCTED TO CONVEY RUNOFF TO THE EXISTING POND/DITCH.
2.C OTHER CONTROLS:
2.C.1 WASTE DISPOSAL:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL DESCRIBE THE PROPOSED METHODS TO PREVENT
THE DISCHARGE OF SOLID MATERIALS, INCLUDING BUILDING MATERIALS, TO WATERS OF THE UNITED STATES. THE
PROPOSED METHODS SHALL INCLUDE AT LEAST THE FOLLOWING, UNLESS OTHERWISE APPROVED BY THE ENGINEER:
* PROVIDING LITTER CONTROL AND COLLECTION WITHIN THE PROJECT DURING CONSTRUCTION ACTIVITIES.
* DISPOSING OF ALL FERTILIZER OR OTHER CHEMICAL CONTAINERS ACCORDING TO EPA'S STANDARD PRACTICES AS
DETAILED BY THE MANUFACTURER.
* DISPOSING OF SOLID MATERIALS INCLUDING BUILDING AND CONSTRUCTION MATERIALS OFF THE PROJECT SITE BUT NOT IN
SURFACE WATERS, OR WETLANDS.
2.C.2 OFF-SITE VEHICLE TRACKING & DUST CONTROL:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL DESCRIBE THE PROPOSED METHODS FOR
MINIMIZING OFFSITE VEHICLE TRACKING OF SEDIMENTS AND GENERATING DUST. THE PROPOSED METHODS SHALL INCLUDE
AT LEAST THE FOLLOWING, UNLESS OTHERWISE APPROVED BY THE ENGINEER.
* COVERING LOADED HAUL TRUCKS WITH TARPAULINS.
* REMOVING EXCESS DIRT FROM ROADS DAILY.
* STABILIZING CONSTRUCTION ENTRANCES ACCORDING TO THE FDEP EROSION AND SEDIMENT CONTROL DESIGNER AND
REVIEWER MANUAL.
* USING ROADWAY SWEEPERS DURING DUST GENERATING ACTIVITIES SUCH AS EXCAVATION AND MILLING OPERATIONS.
2.C.3 STATE AND LOCAL REGULATIONS FOR WASTE DISPOSAL, SANITARY SEWER, OR SEPTIC TANK REGULATIONS:
IN THE SPECIFICATION SECTION 104, EROSION CONTROL PLAN, THE CONTRACTOR SHALL DESCRIBE THE PROPOSED
PROCEDURES TO COMPLY WITH APPLICABLE STATE AND LOCAL REGULATIONS FOR WASTE DISPOSAL, AND SANITARY SEWER
OR SEPTIC SYSTEMS.
2.C.4 FERTILIZERS AND PESTICIDES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL
DESCRIBE THE PROCEDURES FOR APPLYING FERTILIZERS AND PESTICIDES. THE PROPOSED PROCEDURES SHALL COMPLY
WITH APPLICABLE SUBSECTIONS OF SECTION 982 OF THE SPECIFICATIONS.
2.C.5 TOXIC SUBSTANCES:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL PROVIDE A LIST OF TOXIC SUBSTANCES THAT ARE
LIKELY TO BE USED ON THE JOB AND PROVIDE A PLAN ADDRESSING THE GENERATION, APPLICATION, MIGRATION, STORAGE, AND DISPOSAL OF THESE SUBSTANCES.
2.D.4 APPROVED STATE AND LOCAL PLANS AND PERMITS:
* FDEP RULE CHAPTER 62-25 F.A.C.
* CITY OF ST. PETERSBURG ENVIRONMENTAL MANAGEMENT ORDINANCE NUMBER 90-0-0044AA.
3.0 MAINTENANCE:
IN THE SEDIMENT AND EROSION CONTROL PLAN, THE CONTRACTOR SHALL PROVIDE A PLAN FOR MAINTAINING ALL EROSION
AND SEDIMENT CONTROLS THROUGHOUT CONSTRUCTION. THE MAINTENANCE PLAN SHALL AT A MINIMUM, COMPLY WITH THE
FOLLOWING:
* SILT FENCE: MAINTAIN PER SPECIFICATION SECTION 104. THE CONTRACTOR SHOULD ANTICIPATE REPLACING SILT FENCE
ON 12 MONTH INTERVALS.
* SEDIMENT BARRIERS : REMOVE SEDIMENT AS PER MANUFACTURER'S RECOMMENDATIONS OR WHEN WATER PONDS IN
UNACCEPTABLE AMOUNTS OR AREAS.
4.0 INSPECTIONS:
QUALIFIED PERSONNEL SHALL INSPECT THE FOLLOWING ITEMS AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN
24 HOURS OF THE END OF A STORM THAT IS 0.50 INCHES OR GREATER. TO COMPLY, THE CONTRACTOR SHALL INSTALL AND
MAINTAIN RAIN GAUGES AND RECORD THE DAILY RAINFALL. WHERE SITES HAVE BEEN PERMANENTLY STABILIZED, INSPECTIONS SHALL BE CONDUCTED AT LEAST ONCE EVERY MONTH. THE CONTRACTOR SHALL ALSO INSPECT THAT
CONTROLS INSTALLED IN THE FIELD AGREE WITH THE LATEST STORMWATER POLLUTION PREVENTION PLAN.
* POINTS OF DISCHARGE TO WATERS OF THE UNITED STATES.
* POINTS OF DISCHARGE TO MUNICIPAL SEPARATE STORM DRAIN SYSTEMS.
* DISTURBED AREAS OF THE SITE THAT HAVE NOT BEEN FINALLY STABILIZED.
* AREAS USED FOR STORAGE OF MATERIALS THAT ARE EXPOSED TO PRECIPITATION.
* STRUCTURAL CONTROLS.
* STORMWATER MANAGEMENT SYSTEMS.
* LOCATIONS WHERE VEHICLES ENTER OR EXIT THE SITE.
THE CONTRACTOR SHALL INITIATE REPAIRS WITHIN 24 HOURS OF INSPECTIONS THAT INDICATE ITEMS ARE NOT IN GOOD
WORKING ORDER.
IF INSPECTIONS INDICATE THAT THE INSTALLED STABILIZATION AND STRUCTURAL PRACTICES ARE NOT SUFFICIENT TO
MINIMIZE EROSION, RETAIN SEDIMENT, AND PREVENT DISCHARGING POLLUTANTS, THE CONTRACTOR SHALL PROVIDE
ADDITIONAL MEASURES, AS APPROVED BY THE ENGINEER.
5.0 NON-STORMWATER DISCHARGES:
IN THE SPECIFICATION SECTION 104 EROSION CONTROL PLAN, THE CONTRACTOR SHALL IDENTIFY ALL ANTICIPATED
NON-STORMWATER DISCHARGES (EXCEPT FLOWS FROM FIRE FIGHTING ACTIVITIES). THE CONTRACTOR SHALL DESCRIBE
THE PROPOSED MEASURES TO PREVENT POLLUTION OF THESE NON-STORMWATER DISCHARGES. IF THE CONTRACTOR
ENCOUNTERS CONTAMINATED SOIL OR GROUNDWATER, CONTACT DAVE LETTERMAN, DISTRICT HAZARDOUS MATERIALS
COORDINATOR AT (305) 63B-R549.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s s w p p p d i t m t o l k k i n v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CE-104
SWPPP NARATIVE - PAGE 2
ES BF
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s u t i l i t i e s n o r t h d i t b f i e v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CU-101
UTILITY PLAN - NORTH
PARKING LOT
ES BF
N
0 10' 20'
SCALE:
SITE PLAN - NORTH PARKING LOT
1" = 10' (30" x 42" PAPER SIZE)
LEGEND
CONSTRUCTION LIMITS
CONSTRUCTION LIMITS
EXISTING STORM SEWER
EXISTING UNDERGROUND ELECTRIC
EXISTING WATERMAIN
INSTALL STORM SEWER
INSTALL UNDERGROUND ELECTRIC
INSTALL STORM INLETS
INSTALL NEW LIGHT
GENERAL NOTES
1. SEE ELECTRICAL PLANS FOR NEW LIGHTING
LAYOUT AND ADDITIONAL INFORMATION.
SEE ELECTRICAL PLANS FOR
NEW LIGHTING & UNDERGROUND
ELECTRIC (TYP.)
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
FES-106
I. 5.90
75 LF - 15" HDPE @ 0.1%
CBMH-105
R. 9.40
I. 5.97
72 LF - 15" HDPE @ 0.1%
72 LF - 15" HDPE @ 0.1%
CBMH-104
R. 9.20
I. 6.05
64 LF - 15" HDPE @ 0.1%
19 LF - 15" HDPE @ 0.1%
FES-101
I. 6.20
CBMH-102
R. 8.70
I. 6.18
FES-201
I. 6.30
FES-301
I. 4.40
38 LF - 12" RCP @ 3.42%
FES-302
I. 5.70
CBMH-103
R. 9.20
I. 6.12
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s u t i l i t i e s s o u t h d i t m t o l k k i n v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST. PETERSBURG GRAVEL
PARKING
VB3238
01-29-2021
ST. PETERSBURG, FLORIDA
BID DOCUMENTS
BID DOCUMENTS
Date: 01/29/21
CU-102
UTILITY PLAN - SOUTH
PARKING LOT
ES BF
N
0 20' 40'
SCALE:
UTILITY PLAN - SOUTH
1" = 20' (30" x 42" PAPER SIZE)
LEGEND
CONSTRUCTION LIMITS
EXISTING STORM SEWER
EXISTING UNDERGROUND ELECTRIC
EXISTING WATERMAIN
INSTALL STORM SEWER
INSTALL UNDERGROUND ELECTRIC
INSTALL STORM INLETS
INSTALL NEW LIGHT
INSTALL NEW ELECTRIC HANDHOLE
GENERAL NOTES
1. SEE ELECTRICAL PLANS FOR NEW LIGHTING
LAYOUT AND ADDITIONAL INFORMATION.
EXTEND 12" RCP 4.0 LF
3' WIDE CURB CUT
WITH 3 CY OF CLASS 1
RIP-RAP WITH
GEOTEXTILE FABRIC
CONSTRUCTION
LIMITS
3' WIDE CURB CUT
WITH 3 CY OF CLASS 1
RIP-RAP WITH
GEOTEXTILE FABRIC
STORM STRUCTURE SCHEDULE
STRUCTURE
NUMBER DIAMETER (IN) CASTING (NEENAH OR
APPROVED EQUAL) NOTES
FES-101 15" NA
GALVANIZED FLARED END
SECTION W/ RIP-RAP,SEE
DETAIL 2/C-502
CBMH-102 30" R-3067-R SEE DETAIL 11/C-501
CBMH-103 30" R-3067-R SEE DETAIL 11/C-501
CBMH-104 30" R-3067-R SEE DETAIL 11/C-501
CBMH-105 30" R-3067-R SEE DETAIL 11/C-501
FES-106 15" NA
GALVANIZED FLARED END
SECTION W/ RIP-RAP, SEE
DETAIL 2/C-502
FES-201 12" NA GALVANIZED FLARED END
SECTION
FES-301 12" NA
GALVANIZED FLARED END
SECTION W/ RIP-RAP,SEE
DETAIL 2/C-502
FES-302 12" NA GALVANIZED FLARED END
SECTION
SEE ELECTRICAL PLANS
FOR NEW LIGHTING &
UNDERGROUND ELECTRIC (TYP.)
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
BUMPER CURB
AutoCAD SHX Text
SPEED HUMP
AutoCAD SHX Text
BENCH MARK: TOP NUT OF HYDRANT ELEVATION = 10.46 FEET
AutoCAD SHX Text
HOOVER BLVD.
AutoCAD SHX Text
BLDG.
AutoCAD SHX Text
GATE
AutoCAD SHX Text
CONCRETE SLAB
AutoCAD SHX Text H
AutoCAD SHX Text H
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h y v b a s t p e t e r s b u r g g r a v e l p a r k i n g c i v i l c a d f i l e s s h e e t s d e t a i l s d i t m t o l k k i n v e d o t
A
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
IMEG CORP.
14755 PRESTON RD STE 845
DALLAS, TX 75254
972-239-6100
MARIO ARRENDONDO
Project Director
Revisions:
13605 1st Ave. N. #100 Pl ymout h, MN 55441 P 763.412.4000 | F 763.412.4090 | ae-mn.com Anderson Engineering of Minnesota, LLC | Proj # 16104
ST.