This file is a comprehensive Schedule of Line Items spreadsheet for the VA National Acquisition Center's June 2025 Equipment Only Consolidation, detailing medical equipment acquisitions across multiple Veterans Health Administration (VHA) facilities nationwide. The document encompasses equipment requisitions for various medical imaging modalities including X-ray (portable and fixed), mammography, ultrasound, nuclear medicine, and bone density systems, spanning 22 VA healthcare networks (VISNs) from locations including Maine, Vermont, Texas, California, and Florida.

The spreadsheet provides granular details for each equipment line item, including specific facility location, equipment type, quantity, and unique tracking numbers. Each entry includes additional comments and clarifications, with many line items reflecting recent technical specification updates, modifications to transducer requirements, probe configurations, and discussions around clinical functionality. The document appears to be part of a comprehensive equipment replacement and standardization effort, with vendors and VA representatives collaboratively refining technical specifications to ensure competitive bidding while meeting specific clinical needs across different VA medical facilities.

View the file

Other files

File Type Posted
539B50017 - 664B54012 updated.zip ZIP file
Vendor Folders - Updated.zip ZIP file
Amendment 0003 - Continuation Page.pdf PDF
36A79725Q0010 0003.docx DOCX document
JUN 2025 Equipment Only Consolidation Schedule - Updated 9-24-25.pdf PDF
549B50512 - 593B50031 Updated.zip ZIP file
603B54025 - 635B50001 Updated.zip ZIP file
673B50077 - 5345B5007 Updated.zip ZIP file
402B51210 - 499B59025 Updated.zip ZIP file
499B59030 - 528B54202 Updated.zip ZIP file
Amendment 0002 - Continuation Page.pdf PDF
36A79725Q0010 0002.docx DOCX document
635B50003 - 646B52018 Updated.zip ZIP file
528B57019 - 549B50511 Updated.zip ZIP file
646B52019 - 672FC5002 Updated.zip ZIP file
JUN 2025 EQ Consolidation - Schedule of Line Items QA - Updated 9-10-25.xlsx XLSX spreadsheet
Missing Tech Specs and Comp Matrix.zip ZIP file
36A79725Q0010 0001.docx DOCX document
JUN 2025 Equipment Only Consolidation Schedule.pdf PDF
Vendor Folders.zip ZIP file
632B51008 - 662B50021.zip ZIP file
VA Directive 6550 - New Appendix A - published Jun. 2023.pdf PDF
501B50014 - 593B50031.zip ZIP file
Vendor Workup Spreadsheet - 36A79725Q0010.xlsx XLSX spreadsheet
Memorandum for Training.pdf PDF
402B51210- 499B59050.zip ZIP file
663B53008 - 678B52009.zip ZIP file
600B40011 - 630B50023.zip ZIP file
JUN2025 EQ Consolidation - Schedule of Line Items HTM Edits HD 02.xlsx XLSX spreadsheet
688B50016 - 740B50040.zip ZIP file
RFQ 36A79725Q0010.pdf PDF
36A79725Q0010_1.docx DOCX document
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Schedule of Line Items

HTME VISNStationEQ POEquipment TypeQTYComments
VISN 1: VA New England Healthcare System402 BANGOR ME402B51210XR US1
VISN 1: VA New England Healthcare System402 AUGUSTA ME402B51215XR US1
VISN 1: VA New England Healthcare System402 AUGUSTA ME402B51216XR PORT C ARM1
VISN 1: VA New England Healthcare System402 LEWISTON ME402B51217XR US1
VISN 1: VA New England Healthcare System402 AUGUSTA ME402B51218XR US1
VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT405B51002XR US1
VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT405B51003XR US1
VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT405B51004XR US1
VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT405B51005XR US1
VISN 4: VA Stars & Stripes Healthcare Network460 WILMINGTON DE460B58007XR PORT C ARM3
VISN 23: VA Midwest Health Care Network499 FARGO ND - FERGUS FALLS499B59019XR DR1
VISN 23: VA Midwest Health Care Network499 FARGO ND - GRAND FORKS499B59020XR DR1
VISN 23: VA Midwest Health Care Network499 IOWA CITY IA - BURLINGTON499B59021XR RAD1
VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN499B59022XR US3
VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN499B59023XR US2
VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN499B59024XR US1
VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN499B59025XR US5
VISN 23: VA Midwest Health Care Network499 FARGO NV499B59030XR US4
VISN 23: VA Midwest Health Care Network499 FORT MEADE SD499B59031XR US1
VISN 23: VA Midwest Health Care Network499 FORT MEADE SD499B59032XR US2
VISN 23: VA Midwest Health Care Network499 FORT MEADE SD499B59033XR US1
VISN 23: VA Midwest Health Care Network499 OMAHA NE499B59050XR US1
VISN 22: VA Desert Pacific Healthcare Network501 ALBUQUERQUE NM501B50014XR US1
VISN 17: VA Heart of Texas Health Care Network504 AMARILLO TX504B57005NM SPECT CT1
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR MI506B50028XR US1
VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI515B50010XR US3
VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI515B50021NM BONE DEN1
VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI515B50022XR PORT C ARM1
VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI515B50023XR US1
VISN 8: VA Sunshine Healthcare Network516 BAY PINES FL516B50006XR US2
VISN 8: VA Sunshine Healthcare Network516 BAY PINES FL516B50007XR US1
VISN 5: VA Capitol Health Care Network517 BECKLEY517B51001XR RF1
VISN 17: VA Heart of Texas Health Care Network519 BIG SPRING TX519B50024XR CT1
VISN 1: VA New England Healthcare System523 WEST ROXBURY MA523B51011XR CATH LAB1
VISN 1: VA New England Healthcare System523 BOSTON MA523B51012XR US1
VISN 2: VA Healthcare Network Upstate New York528 BUFFALO NY528B50327XR US1
VISN 2: VA Healthcare Network Upstate New York528 SYRACUSE NY528B54202XR MRI1Update in Modality
VISN 2: VA Healthcare Network Upstate New York528 SYRACUSE NY528B54202XR US1
VISN 2: VA Healthcare Network Upstate New York528 BATH NY528B57019NM BONE DEN1
VISN 2: VA Healthcare Network Upstate New York528 BATH NY528B57020XR US3
VISN 4: VA Stars & Stripes Healthcare Network529 BUTLER PA529B52004XR US1
VISN 7: VA Southeast Health Care Network534 CHARLESTON SC5345B5007XR PORT C ARM1
VISN 7: VA Southeast Health Care Network534 CHARLESTON SC534B52019XR US2
VISN 7: VA Southeast Health Care Network534 CHARLESTON SC534B52032XR PORT C ARM1
VISN 10: VA Healthcare System of Ohio538 CHILLICOTHE OH538B50002XR PORT RAD2
VISN 10: VA Healthcare System of Ohio539 CINCINNATI OH539B50017XR RAD1
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B51011XR PORT RAD3
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B51012XR US1
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B51013XR US7
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B51014XR US4
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B51015XR US1
VISN 4: VA Stars & Stripes Healthcare Network542 COATESVILLE PA542B50003XR PORT C ARM1
VISN 4: VA Stars & Stripes Healthcare Network542 COATESVILLE PA542B50004XR US1
VISN 8: VA Sunshine Healthcare Network546 MIAMI FL546B50006XR CT1Removed
VISN 8: VA Sunshine Healthcare Network546 MIAMI FL546B50007XR PORT RAD4
VISN 8: VA Sunshine Healthcare Network546 MIAMI FL546B50009XR US1
VISN 17: VA Heart of Texas Health Care Network549 TYLER TX549B50493XR RAD1
VISN 17: VA Heart of Texas Health Care Network549 FORT WORTH TX549B50511XR CT1
VISN 17: VA Heart of Texas Health Care Network549 DALLAS TX549B50512XR PORT RAD5
VISN 17: VA Heart of Texas Health Care Network549 DALLAS TX549B50513XR US1
VISN 10: VA Healthcare System of Ohio552 DAYTON OH552B50004XR PORT C ARM2
VISN 10: VA Healthcare System of Ohio552 DAYTON OH552B50012XR PORT C ARM1
VISN 10: VA Healthcare System of Ohio552 DAYTON OH552B50014XR PORT RAD1
VISN 10: VA Healthcare System of Ohio552 DAYTON OH552B50020XR US1
VISN 10: VA Healthcare System of Ohio552 DAYTON OH552B50022XR PORT C ARM1
VISN 10: VA Healthcare System of Ohio552 DAYTON OH552B50027XR US1
VISN 19: VA Rocky Mountain Network554 AURORA CO554B53018XR US2
VISN 19: VA Rocky Mountain Network554 DENVER CO554B53021XR PORT RAD1Removed
VISN 19: VA Rocky Mountain Network554 DENVER CO554B53022XR US5
VISN 12: VA Great Lakes Health Care System556 NORTH CHICAGO, IL556B51005XR US4
VISN 12: VA Great Lakes Health Care System556 NORTH CHICAGO, IL556B51013XR US3
VISN 6: VA Mid-Atlantic Health Care Network558 DURHAM NC558B49030XR PORT C ARM1
VISN 6: VA Mid-Atlantic Health Care Network558 DURHAM NC558B59003XR US2
VISN 6: VA Mid-Atlantic Health Care Network558 DURHAM NC558B59008XR US1
VISN 6: VA Mid-Atlantic Health Care Network558 DURHAM NC558B59009XR US1
VISN 6: VA Mid-Atlantic Health Care Network558 DURHAM NC558B59010XR PORT C ARM1
VISN 2: VA Healthcare Network Upstate New York561 EAST ORANGE NJ561B50010XR PORT C ARM1
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE FL573B55017XR US2
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE FL573B55018XR US3
VISN 8: VA Sunshine Healthcare Network573 GAINESVILLE FL573B55019NM BONE DEN1Updated Modality
VISN 16: South Central VA Health Care Network580 HOUSTON TX580B50015XR US2
VISN 16: South Central VA Health Care Network580 HOUSTON TX580B50049XR US1
VISN 16: South Central VA Health Care Network580 HOUSTON TX580B50050XR PORT C ARM1
VISN 5: VA Capitol Health Care Network581 HUNTINGTON WV581B52062XR PORT C ARM1
VISN 21: VA Sierra Pacific Network593 LAS VEGAS NV593B50027NM SPECT CT1
VISN 21: VA Sierra Pacific Network593 LAS VEGAS NV593B50028NM SPECT CT1
VISN 21: VA Sierra Pacific Network593 LAS VEGAS NV593B50029XR CT1
VISN 21: VA Sierra Pacific Network593 LAS VEGAS NV593B50031XR US1
VISN 22: VA Desert Pacific Healthcare Network600 LONG BEACH CA600B40011XR US1Removed
VISN 22: VA Desert Pacific Healthcare Network600 LONG BEACH CA600B50008XR PORT C ARM1Removed
VISN 9: VA Mid South Healthcare Network603 LOUISVILLE KY603B54024NM BONE DEN1
VISN 9: VA Mid South Healthcare Network603 LOUISVILLE KY603B54025XR PORT RAD5
VISN 9: VA Mid South Healthcare Network603 LOUISVILLE KY603B54026XR PORT C ARM1
VISN 9: VA Mid South Healthcare Network603 LOUISVILLE KY603B54032XR MAMMO2
VISN 9: VA Mid South Healthcare Network603 LOUISVILLE KY603B54033XR PORT C ARM4
VISN 21: VA Sierra Pacific Network612 MARTINEZ CA612B59008XR PORT C ARM1
VISN 21: VA Sierra Pacific Network612 MARTINEZ CA612B59009XR PORT C ARM1
VISN 5: VA Capitol Health Care Network613 MARTINSBURG WV613B51013XR US2
VISN 9: VA Mid South Healthcare Network614 MEMPHIS TN614B54004XR PORT C ARM5
VISN 9: VA Mid South Healthcare Network614 MEMPHIS TN614B54005XR PORT C ARM2
VISN 9: VA Mid South Healthcare Network621 MOUNTAIN HOME TN621B50002XR US6
VISN 19: VA Rocky Mountain Network623 MUSKOGEE OK623B54009XR US1
VISN 9: VA Mid South Healthcare Network626 NASHVILLE TN626B54045XR US2
VISN 16: South Central VA Health Care Network629 NEW ORLEANS LA629B50010XR US11
VISN 2: VA Healthcare Network Upstate New York630 NEW YORK NY630B40011XR US3
VISN 2: VA Healthcare Network Upstate New York630 MANHATTAN NY630B50023XR US1
VISN 2: VA Healthcare Network Upstate New York632 NORTHPORT NY632B51008XR US2
VISN 2: VA Healthcare Network Upstate New York632 NORTHPORT NY632B51009XR US2
VISN 2: VA Healthcare Network Upstate New York632 NORTHPORT NY632B51010XR RF1
VISN 19: VA Rocky Mountain Network635 OKLAHOMA CITY OK635B50000NM BONE DEN1
VISN 19: VA Rocky Mountain Network635 OKLAHOMA CITY OK635B50001XR US1
VISN 19: VA Rocky Mountain Network635 OKLAHOMA CITY OK635B50003XR RAD1
VISN 19: VA Rocky Mountain Network635 OKLAHOMA CITY OK635B50006XR RAD1
VISN 6: VA Mid-Atlantic Health Care Network637 ASHEVILLE NC637B59005NM BONE DEN1Update in Modality
VISN 6: VA Mid-Atlantic Health Care Network637 ASHEVILLE NC637B59006XR US3
VISN 21: VA Sierra Pacific Network640 PALO ALTO CA640B54008XR US1
VISN 21: VA Sierra Pacific Network640 PALO ALTO CA640B54009XR US1
VISN 21: VA Sierra Pacific Network640 PALO ALTO CA640B54011NM BONE DEN1
VISN 21: VA Sierra Pacific Network640 PALO ALTO CA640B54012NM BONE DEN1
VISN 21: VA Sierra Pacific Network640 PALO ALTO CA640B54013XR PORT C ARM1Update in Modality
VISN 21: VA Sierra Pacific Network640 PALO ALTO CA640B54014XR PORT C ARM2
VISN 4: VA Stars & Stripes Healthcare Network642 PHILADELPHIA PA642B59007XR RF1Update in Modality
VISN 4: VA Stars & Stripes Healthcare Network642 PHILADELPHIA PA642B59009XR US1
VISN 22: VA Desert Pacific Healthcare Network644 PHOENIX AZ644B58020XR US1
VISN 22: VA Desert Pacific Healthcare Network644 PHOENIX AZ644B58022XR US2
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52001XR RAD1
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52006XR RF1TS & CM were in Consolidation, but it was missing from schedule
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52013XR RF1Update in Modality
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52015XR RF1
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52016XR RF1
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52017XR CT1
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52018XR RAD1
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B52019XR RAD1
VISN 20: VA Northwest Network648 PORTLAND OR648B53005XR US1
VISN 20: VA Northwest Network648 PORTLAND OR648B53006XR US16
VISN 1: VA New England Healthcare System650 PROVIDENCE RI650B51007XR PORT C ARM3Update in Modality
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59003XR PORT RAD1
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59004XR US2
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59007XR US1
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59008XR US1
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59011XR US2
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59013NM SPECT1Update in Modality
VISN 20: VA Northwest Network653 ROSEBURG OR653B53000XR US1
VISN 21: VA Sierra Pacific Network654 RENO NV654B50036XR US1
VISN 15: VA Heartland Healthcare Network657 ST LOUIS MO657B50008XR CT1
VISN 6: VA Mid-Atlantic Health Care Network658 SALEM VA658B59009XR RF1
VISN 6: VA Mid-Atlantic Health Care Network659 SALEM VA658B59010XR US1
VISN 6: VA Mid-Atlantic Health Care Network659 KERNERSVILLE NC659B59000XR RF1
VISN 6: VA Mid-Atlantic Health Care Network659 CHARLOTTE NC659B59002XR RF1
VISN 19: VA Rocky Mountain Network660 SALT LAKE CITY UT660B50004XR US9
VISN 19: VA Rocky Mountain Network660 SALT LAKE UT660B50005XR MAMMO1
VISN 21: VA Sierra Pacific Network662 SAN FRANCISCO CA662B50014XR PORT C ARM1
VISN 21: VA Sierra Pacific Network662 SAN FRANCISCO CA662B50021XR US1
VISN 20: VA Northwest Network663 SEATTLE WA663B53008XR US3
VISN 20: VA Northwest Network663 SEATTLE WA663B53009XR US2
VISN 20: VA Northwest Network663 SEATTLE WA663B53010XR US4
VISN 20: VA Northwest Network663 SEATTLE WA663B53012XR US1
VISN 20: VA Northwest Network663 SEATTLE WA663B53013XR US1
VISN 20: VA Northwest Network663 SEATTLE WA663B53014XR PORT C ARM1
VISN 22: VA Desert Pacific Healthcare Network664 SAN DIEGO CA664B54012XR MAMMO1
VISN 16: South Central VA Health Care Network667 SHREVEPORT LA667B59031XR US1
VISN 8: VA Sunshine Healthcare Network672 SAN JUAN PR672FC5002XR US1
VISN 8: VA Sunshine Healthcare Network673 TAMPA FL673B40053XR US1
VISN 8: VA Sunshine Healthcare Network673 TAMPA FL673B50073XR US3
VISN 8: VA Sunshine Healthcare Network673 TAMPA FL673B50077XR IR1
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B50233XR US1
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B50357XR US2
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B50372XR US3
VISN 8: VA Sunshine Healthcare Network675 ORLANDO FL675B57003XR US1
VISN 8: VA Sunshine Healthcare Network675 ORLANDO FL675B57004XR PORT C ARM2
VISN 8: VA Sunshine Healthcare Network675 ORLANDO FL675B57005XR US4
VISN 22: VA Desert Pacific Healthcare Network678 TUCSON AZ678B52008XR US2
VISN 22: VA Desert Pacific Healthcare Network678 TUCSON AZ678B52009XR US2
VISN 5: VA Capitol Health Care Network688 WASHINGTON DC688B50016XR MAMMO1
VISN 5: VA Capitol Health Care Network688 WASHINGTON DC688B51008XR US2
VISN 5: VA Capitol Health Care Network688 WASHINGTON DC688B51009XR US8
VISN 1: VA New England Healthcare System689 WEST HAVEN CT689B51004XR US3
VISN 1: VA New England Healthcare System689 WEST HAVEN CT689B51005XR US1
VISN 1: VA New England Healthcare System689 WEST HAVEN CT689B51006XR US1
VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN TX740B50038XR US3Updated quantity
VISN 17: VA Heart of Texas Health Care Network740 HARLINGEN TX740B50040XR US2

Q&A

VISN LookupEQUIPMENT REQUISTION NUMBERHTME VISNStationVENDOR EQUIPMENT QUESTIONSGOVERNMENT EQUIPMENT RESPONSE
VISN 1: VA New England Healthcare System402B51210VISN 1: VA New England Healthcare System402 BANGOR ME1.l. Can the weight be raised to 290 lbs to increase competition?Technical specifications updated.
VISN 1: VA New England Healthcare System402B51215VISN 1: VA New England Healthcare System402 AUGUSTA MERequest 2.j. Minimum Battery Life 30 mins moved to Value Add Section.
Request 6.k. Ability to enter standby mode or sleep mode be moved to Value Add Section.Technical specifications updated.
VISN 1: VA New England Healthcare System402B51217VISN 1: VA New England Healthcare System402 LEWISTON ME1.l. Can the weight be raised to 290 lbs to increase competition?Technical specifications updated.
VISN 1: VA New England Healthcare System402B51218VISN 1: VA New England Healthcare System402 AUGUSTA MERequest 2.j. Minimum Battery Life 30 mins moved to Value Add Section.
Request 6.k. Ability to enter standby mode or sleep mode be moved to Value Add Section.Technical specifications updated.
VISN 1: VA New England Healthcare System405B51002VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT2.j. Can the weight be raised to 290 lbs to increase competition?Technical specifications updated.
VISN 1: VA New England Healthcare System405B51002VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT9. Is Fusion clinically necessary?highly preferred feature-moved to added value; see updated technical specifications/matrix
VISN 1: VA New England Healthcare System405B51002VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VTRequest item 2.j. Maximum equipment weight be increased from 250 to 265.

Request item 9.c. Tracking and recording of needle movement during biopsy in 3D coordinates in real-time be removed or moved to Added Value.

Request item 9.d. Availability of projected, future needle movement during biopsy in 3D coordinates be removed or moved to Added Value.

Request item 9.f. 3D-generated model of prostate that can be exported to report, adjustable by additional non-imaging information, such as pathology-related data be removed or moved to Added Value.

Request item 9.g. Semi-robotic arm, physically attached to biopsy system, with at least 3 degrees of freedom used to stabilize needle and ultrasound probe movements be removed or moved to Added Value.Concur with all requests; Technical specifications updated.
VISN 1: VA New England Healthcare System405B51003VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT2.j. Can the weight be raised to 290 lbs to increase competition?Technical specifications updated.
VISN 1: VA New England Healthcare System405B51003VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VT9. Is Fusion clinically necessary?highly preferred feature-moved to added value; see updated technical specifications/matrix
VISN 1: VA New England Healthcare System405B51003VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VTRequest item 2.j. Maximum equipment weight be increased from 250 to 265.

Request item 9.c. Tracking and recording of needle movement during biopsy in 3D coordinates in real-time be removed or moved to Added Value.

Request item 9.d. Availability of projected, future needle movement during biopsy in 3D coordinates be removed or moved to Added Value.

Request item 9.f. 3D-generated model of prostate that can be exported to report, adjustable by additional non-imaging information, such as pathology-related data be removed or moved to Added Value.

Request item 9.g. Semi-robotic arm, physically attached to biopsy system, with at least 3 degrees of freedom used to stabilize needle and ultrasound probe movements be removed or moved to Added Value.Concur with all requests; Technical specifications updated.
VISN 1: VA New England Healthcare System405B51004VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VTRequest 1.i. Minimum Battery Life 60 mins moved to Value Add Section.

Request item 1.k. Maximum equipment weight be increased from 250lbs to 265lbs.

Request 5.k. Ability to enter standby mode or sleep mode be moved to Value Add Section.Concur with all requests; Technical specifications updated.
VISN 1: VA New England Healthcare System405B51005VISN 1: VA New England Healthcare System405 WHITE RIVER JUNCTION VTRequest 1.i. Minimum Battery Life 60 mins moved to Value Add Section.

Request item 1.k. Maximum equipment weight be increased from 250lbs to 265lbs.

Request 5.k. Ability to enter standby mode or sleep mode be moved to Value Add Section.Concur with all requests; Technical specifications updated.
VISN 4: VA Stars & Stripes Healthcare Network460B58007460 WILMINGTON DERemove the vendor references from the matrix.Technical specifications updated.
VISN 23: VA Midwest Health Care Network499B59021499 IOWA CITY IA - BURLINGTONSection 1a.a. would you consider a Fixed 17 x17 detector in the wall stand and a wireless 17 x17 detector in the table?No, this is not the preferred setup
VISN 23: VA Midwest Health Care Network499B59021499 IOWA CITY IA - BURLINGTONSection 1 b.a. Would you consider a wireless 17 x17 detector in the table and a wireless 17 x 17 in the wall stand?Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59021499 IOWA CITY IA - BURLINGTONDo you define auto positioning as a fully robotic system with pre-programed automated movements completed by a remote control? Or are you seeking some automated movements such a tube/detector tracking and auto centering to detectors?Defined as fully robotic with pre-programmed movements via remote
VISN 23: VA Midwest Health Care Network499B59021VISN 23: VA Midwest Health Care Network499 IOWA CITY IA - BURLINGTON3.n. Motor-driven tabletop movement in the X and Y axis at stated maximum weight capacity - please remove as this is more appropriate for RF.
Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59021VISN 23: VA Midwest Health Care Network499 IOWA CITY IA - BURLINGTON1.Would you please provide us with CAD drawings for this room?No, the space does not exist yet
VISN 23: VA Midwest Health Care Network499B59022VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN7.a. Can "configurable buttons to Freeze, Print, and Store" probe be moved to the value-add section to increase competition? Every system has these features (Freeze, Print, Store) on its console? This probe is vendor-specific and should be updated to increase competitionTechnical specification updated.
VISN 23: VA Midwest Health Care Network499B59023499 MINNEAPOLIS MNCan we verify equipment weight and if the transducers are correct?The equipment weight and transducers are correct
VISN 23: VA Midwest Health Care Network499B59023VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN8.c. Can "configurable buttons to Freeze, Print, and Store" on the probe be moved to the value-add section to increase competition? Every system has these features (Freeze, Print, Store) on its console? This probe is vendor-specific and should be updated or removed to increase competition.Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59023VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN2.g. Can the weight be increased to 55Lb including cart and systemto increase competition?No, the providers will occasionally use this system off-cart. It must be able to be transported in a case.
VISN 23: VA Midwest Health Care Network499B59024499 MINNEAPOLIS MNCan we verify equipment weight and if the transducers are correct?The equipment weight and transducers are correct
VISN 23: VA Midwest Health Care Network499B59024VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN2.g. Can the weight be increased to 55Lb including cart and systemto increase competitionNo, the providers will occasionally use this system off-cart. It must be able to be transported in a case.
VISN 23: VA Midwest Health Care Network499B59024VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN8.a. Can "configurable buttons to Freeze, Print, and Store" on probe, be moved to the value-add section to increase competition? Every system has these features (Freeze, Print, Store) on its console?Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59025VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN2.f. Can Maximum weight be increased to 125 Lbs to increase competition?No, the system needs to be light and maneuverable to navigate our small exam rooms
VISN 23: VA Midwest Health Care Network499B59025VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN6.d Can the system boot up time be increased to 80 seconds to increase competition?Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59025VISN 23: VA Midwest Health Care Network499 MINNEAPOLIS MN7.h. Can a traditional hard drive with 128Gb or greater hard drive also be included in spec to increase competition?Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59030VISN 23: VA Midwest Health Care Network499 FARGO ND1.i. Can Maximum weight be increased to 125 Lbs to increase competition?No, the system needs to be light and maneuverable to navigate our small exam rooms
VISN 23: VA Midwest Health Care Network499B59030VISN 23: VA Midwest Health Care Network499 FARGO ND8.a. Is the capablity of accepting MRI and ultrasound images from other modalities critical to patient care or can this be moved to value-add section?Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59030VISN 23: VA Midwest Health Care Network499 FARGO NDRequest item 8.a. Capable of accepting MRI (both 1.5T and 3.0T) and ultrasound images from other modalities as input and displaying these images on a screen be removed or moved to Added Value.Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59031VISN 23: VA Midwest Health Care Network499 FORT MEADE SD2.g. Is elastography clinically necessary as this system is configured for IV access? If needed, please provide more details on the care areas where elastography will be used as this can cover a wide variety of areas.No
VISN 23: VA Midwest Health Care Network499B59031VISN 23: VA Midwest Health Care Network499 FORT MEADE SD4.a. Can the system have both a touchscreen and a physical console with controls?Yes
VISN 23: VA Midwest Health Care Network499B59031VISN 23: VA Midwest Health Care Network499 FORT MEADE SD5.d. Can the phantom used for quality control be removed? These can be found in Biomed or purchased from a QA /QC site.Yes
VISN 23: VA Midwest Health Care Network499B59031VISN 23: VA Midwest Health Care Network499 FORT MEADE SD6.d. Can the reuable needle guide be moved to value add section? These can be purchase seperatlely from Civco.Yes
VISN 23: VA Midwest Health Care Network499B59032VISN 23: VA Midwest Health Care Network499 FORT MEADE SDRequest 1.f. Minimum Battery Life 180 mins moved to Value Add Section.
Request 5.f. Ability to enter standby mode or sleep mode be moved to Value Add Section.Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59033VISN 23: VA Midwest Health Care Network499 FORT MEADE SD5.d. Are the "leakage test kit for transducers listed in Section 7" clinical necessary or can this be moved to value add section?Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59033VISN 23: VA Midwest Health Care Network499 FORT MEADE SD5.e. Are "sterile processing trays" clinical necessary" can these be moved to value add section?Technical specification updated.
VISN 23: VA Midwest Health Care Network499B59033VISN 23: VA Midwest Health Care Network499 FORT MEADE SD7.a. Can an endfire & transperineal type prostate probes be included in spec to increase competition? This Triplane transducer is lock out and reduces competitivenessNo
VISN 23: VA Midwest Health Care Network499B59050VISN 23: VA Midwest Health Care Network499 OMAHA NE2.c. Is navigation software clinically necessary or can this be moved to value add section. This software is typically used in Interventional RadiologyTechnical specification updated.
VISN 23: VA Midwest Health Care Network499B59050VISN 23: VA Midwest Health Care Network499 OMAHA NE6.k. Can AI fibroid mapping be moved to value-add section to increase competition?Technical specification updated.
VISN 22: VA Desert Pacific Healthcare Network501B50014VISN 22: VA Desert Pacific Healthcare Network501 ALBUQUERQUE NMRequest item 5.j. j. Ability to enter standby mode or sleep mode be removed or moved to Added Value.Yes, it can be moved to Added Value
VISN 17: VA Heart of Texas Health Care Network504B57005504 AMARILLO TXLine 12 Please confirm that the existing Siemens SPECT camera will be the trade in but does not include any description, the serial number, collimators or if in working order. PLUS line 154 states their is no tradeYes, the Siemens will be a trade in. Serial #:1167, Siemens Symbia E, LEHR, MEHR, Pinhole. System is in working condition. Document amended with trade in information
VISN 17: VA Heart of Texas Health Care Network504B57005504 AMARILLO TXLine 22 States 64 slices, will reconstructed slices to 64 be acceptable?Technical specifications updated.
VISN 17: VA Heart of Texas Health Care Network504B57005504 AMARILLO TXUnit physical specification Line 26e energy range 40-250kev. Will the system not be performing high energy studies in the future?There is a possibility it will be performing high energy studies in the future.
VISN 17: VA Heart of Texas Health Care Network504B57005504 AMARILLO TXCollimator specifications. Line 34 references low energy high resolution and line 35 references low energy. Is this referring to a general purpose collimator?We will only need high resolution, medium energy and a pin hole collimator
VISN 17: VA Heart of Texas Health Care Network504B57005504 AMARILLO TXAdvanced specification Line 78 requests for SPECT/CT applications. Which package would fulfill this specification ? 4DMSPECT or Cedars?Cedars. Document amended
VISN 17: VA Heart of Texas Health Care Network504B57005504 AMARILLO TXSoftware requirements Line 94 lists neurology quantification software. What neurology applications are being requested?No neuro applications will be needed. Document amended
VISN 17: VA Heart of Texas Health Care Network504B57005VISN 17: VA Heart of Texas Health Care Network504 AMARILLO TX1j & 1k: Please remove as these are not specs that we measure and publish

4b: Is a MIM software only solution (that is server based and maintained by the VA) an acceptable solution 4g: Please move to Value Adds as only one vendor can meet this requirement 5g: Please remove as this is not something that is done in a NM department 6e: Please remove to allow for fair and full competition as only one vendor can meet this requirement 6l: Please remove to allow for fair and full competition as only one vendor can meet this requirement 6n: Please remove as only one vendor can meet this requirement 1j & 1k: Requirement will remain as is 4b: MIM would be acceptable.

4g: Requirement will remain as is 5g: This can be removed. Document amended 6e: This can be removed. Document amended 6I: This can be removed. Document amended 6n: This can be removed. Document amended NAC-HTME 506B50028 VISN 10: VA Healthcare System of Ohio Missing from Spreadsheet.

Request item 1.h. Minimum number of transducer ports 5 reduced to 4.

Request Maximum equipment dimensions of 68 x 6 x 7 be increased to 68 x 24 x 36.Has been added to the spreadsheet
VISN 10: VA Healthcare System of Ohio515B50010VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MIFusion software was included in the matrix and tech specs but it wasnt requested from the customer during the demo and initial/original quoting period.

Does this need to be included in the quote?

Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50010VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI2.c. Is navigation software clinically necessary or can this be moved to value add section?Navigation moved to added value.
VISN 10: VA Healthcare System of Ohio515B50010VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI6.o. Can the phantom used for quality control be removed? These can be found in Biomed or purchased from a QA /QC siteTechnical specification removed.
VISN 10: VA Healthcare System of Ohio515B50010VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MITechnical Spec is empty.Technical specification updated.
VISN 10: VA Healthcare System of Ohio515B50010VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MIBenchmark is an Ultrasound and Posted but on Spreadsheet as XR RF.XR US
VISN 10: VA Healthcare System of Ohio515B50010VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MIObligation 515B50010 has a quantity of 3 for the Schedule of Line Items, but has a quantity of 1 on the Technical Specifications. Need to know what is the true quantity for this line item for product submission.Quantity is 3.
VISN 10: VA Healthcare System of Ohio515B50021VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI1h: please change to 778 lbs for open competition1.h Reducing max system weight will not open competition
VISN 10: VA Healthcare System of Ohio515B50022VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MILINE 20 PORTABLE C-ARM, . This also includes a PDF of the Matrix rather than the usual excel sheet. Can the Government provide an Excel Matrix to be filled in.Compliance matrix provided to NAC HTME
VISN 10: VA Healthcare System of Ohio515B50022VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MIPhilips received documents for the requirement, however, the matrix is in PDF format instead of Excel and cannot be properly editedCompliance matrix provided to NAC HTME
VISN 10: VA Healthcare System of Ohio515B50022515 BATTLE CREEK MIPlease clarify the modality as there is no mobile c-arm that can meet this requirement.Requirement not specificed
VISN 10: VA Healthcare System of Ohio515B50022VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI3.b. Is "three dimensional (3D)-Freehand" clinically necessary or can this be moved to value add section? Should vendors include 3D/4D software?Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50022VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI3.c. Is "navigation software" clinically necessary or can this be moved to value add section. This software add additional cost to systems and is rarely used.Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50022VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI5.o. Can the phantom used for quality control be removed? These can be found in Biomed or purchased from a QA /QC site.Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI1.k. Can the system weight be increased to 125 Lbs to increase competition, as we meet the size specifications?Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI2.c. Is navigation software clinically necessary or can this be moved to value add section? This procedure would not be used for MSK.2.c moved to added value
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI2.b. Is "three-dimensional (3D)-Freehand clinical necessary for the podiatry department? Can this moved to value-add section?2.b moved to added value
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI5.j. Can the phantom used for quality control be removed? These can be found in Biomed or purchased from a QA /QC site.Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI8.a. Is "tracking and recording the needle movement during biopsy in 3D coordinates in real time" clinically necessary for the podiatry clinic? This is a radiology or urology feature used during biopsyTechnical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK MI8.b. Can "availability of projected future needle movement during biospy in 3D coordinate" be removed. This is feature used in radiology and not podiatry.Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK, MIIn section 4, rows 50 and 51, the requirements are a physical keyboard and a touchscreen monitor. Will the ability to connect a USB keyboard suffice? If there are two screens, is it okay if only one screen is touchscreen? Please consider changing this requirement to encourage fair competition.4.a updated to include USB keyboard compatibility. 4.b moved to added value
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK, MIIn section 4, row 52, the requirement is: Articulating support arm to allow for vertical and horizontal adjustment of the monitors for viewing from anywhere in the room. Systems with laptop-style form factors do not have articulating arms. Please consider changing this specification to encourage fair competitionTechnical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK, MIIn section 8, row 78, the requirements is: Tracking and recording of needle movement during biopsy in 3D coordinates in real-time. Why is this needed for podiatry?Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK, MIIn section 8, row 79, the requirements is: Availability of projected, future needle movement during biopsy in 3D coordinates. Why is this necessary for podiatry?Technical specification removed.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK, MIFor minimum screen size, Please consider changing the minimum screen size to 18 inches for increased visibility and clinical superiorityTechnical specification updated.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK, MIPlease consider adding the requirement to scan on battery, as this provides greater clinical superiority and staff satisfaction?Ability to scan on battery added to section 5.
VISN 10: VA Healthcare System of Ohio515B50023VISN 10: VA Healthcare System of Ohio515 BATTLE CREEK, MIDo you need 2D/3D/4D capability on this system?2D/3D
VISN 8: VA Sunshine Healthcare Network516B50006VISN 8: VA Sunshine Healthcare Network516 BAY PINES FLAdditional Specification, d. specific applications - Please confirm the need for HPB Surgery
Additional Specification, d. specific applications - Please confirm the need for Laporscopic & Robotic software application as Requirement overview statues system will be used for Urology exams and procedures.Per the original Technical Specifications, this requirement does not include HPB Surgery, or Robotic Procedure packages.
VISN 8: VA Sunshine Healthcare Network516B50007VISN 8: VA Sunshine Healthcare Network516 BAY PINES FLAdditional Specification, d. specific applications - requirement states HPB Surgery application. If required, what HPB probes are needed?

Additional Specification, d. specific applications - requirement states Laporscopic & Robotic software application. If required, what Laporscopic & Robotic probes are needed? Yes, this requirement includes HPB Surgery and Robotic Procedure software.

Per the technical specifications, the facility requires quantity four (4) Biplane Endocavity Transducers, 14-4 MHz.

VISN 5: VA Capitol Health Care Network517B51001VISN 5: VA Capitol Health Care Network517 BECKLEY, WVThis obligation was not in master matrix tracker attached, is obligation 517B51001 in or out? if in the matrix needs to be updated, if out it needs communicated.The technical specifications and matrix are included in this consolidation for 517B51001
VISN 5: VA Capitol Health Care Network517B51001VISN 5: VA Capitol Health Care Network517 BECKLEY WV1.Would you please provide us with CAD drawings for this room?CAD drawings are not needs as turnkey is NOT a part of this consolidation
VISN 17: VA Heart of Texas Health Care Network519B50015VISN 17: VA Heart of Texas Health Care Network519 BIG SPRING TX3.b is "three-dimensional (3D)-freehand" clinically necessary, can this be moved to "value add" section?This was part of the March 2025 consolidation
VISN 17: VA Heart of Texas Health Care Network519B50024VISN 17519 BIG SPRING TX1.l Please clarify, the mA listed is outside most system ranges. Typically, the usable mA range is 10-600 mAPlease state your minimum requirement
VISN 17: VA Heart of Texas Health Care Network519B50024VISN 17519 BIG SPRING TXk. Partial system UPS – maintains full functionality of the system for a minimum of 7 minutes during a power outage, Partial UPS only covers computers and will not allow the system to continue scanning. Are you looking for a Full UPS?Partial UPS is being requested
VISN 17: VA Heart of Texas Health Care Network519B50024VISN 17519 BIG SPRING TX5f. Integration to Dose Tracking System – Radimetrics. Are both the radiation and contrast dose required?Both the radiation and contrast dose are required
VISN 17: VA Heart of Texas Health Care Network519B50024519 BIG SPRING TXSection 1 Line 32 l. Please change the minimum mA range to 10-1100mA this is the range for a single source CTThe requirement will remain as is
VISN 17: VA Heart of Texas Health Care Network519B50024519 BIG SPRING TXSection 2 Line 34/35 a.b. Regarding CT Fluoroscopy is a large ceiling-mounted monitor or single cart-mounted monitor preferred?CT Fluoroscopy has been removed as a requirement.
VISN 17: VA Heart of Texas Health Care Network519B50024VISN 17: VA Heart of Texas Health Care Network519 BIG SPRING TX3c. Is an AW workstation required if post processing functions can be performed on the console.
4b. Please elaborate on the type of clinical functions you’re looking to achieve.2 in 1 workstations are acceptable.
VISN 1: VA New England Healthcare System523B51011VISN 1: VA New England Healthcare System523 WEST ROXBURY MA1.Would you please provide us with CAD drawings for this room?CAD files are not necessary because this is not a turnkey
VISN 1: VA New England Healthcare System523B51011VISN 1: VA New England Healthcare System523 WEST ROXBURY MA2s.) :Ability for tabletop to move in cradle motion (side to side)

Q: Please remove this requirement to allow for fair competition or move to the added value section.

2y.) Table Cradle Q: Please remove this requirement to allow for fair competition or move to the added value section. 2 s) no this is a clinical requirement 2.y) no this is a clinical requirement VISN 1: VA New England Healthcare System 523B51012 VISN 1: VA New England Healthcare System 523 BOSTON MA Scanning Modes: d. Image Fusion Software. Please confirm the need for Fusion.

If Fusion is required, will it be needed for TP, TR, of both?

If Fusion is required, will it be required to be freehand or stabilized?

6. Analysis packages h. cardiovascular clinical - what procedures are being performed with this application? 2. Scanning Modes d. Image Fusion Software - not required & removed; see updated technical specifcations/matrix

6. Analysis packages h. cardiovascular clinical - not required & removed; see updated technical specifcations/matrix

VISN 2: VA Healthcare Network Upstate New York528B54202VISN 2 VA Healthcare Syracuse NY528 SYRACUSE NYPlease remove the spec in added value ROW N; unfair requirement no added patient value?Veterans with PTSD, Head/feet is requested by Staff
VISN 2: VA Healthcare Network Upstate New York528B54202VISN 2 VA Healthcare Syracuse NY528 SYRACUSE NYPlease provide CAD drawings for the room/area that the MR will be installed?CAD files are not necessary because this is not a turnkey
VISN 2: VA Healthcare Network Upstate New York528B54202VISN 2: VA Healthcare Network Upstate New York528 SYRACUSE NY528B54202, 528 SYRACUSE NY has two separate lines on the Consolidation (Line 54 and 57). Can you clarify why this is duplicated or should it be a different Obligation number?Only one line item for Syracuse submitted. It is for an MRI
VISN 2: VA Healthcare Network Upstate New York528B54202528 SYRACUSE NYLine 63 - Please confirm the request for an additional processing/reading station in addition to the scanning consoleMinimum of 1 required
VISN 2: VA Healthcare Network Upstate New York528B54202528 SYRACUSE NYThis obligation is listed as Equipment Type: US and the Tech Specs and Matrix details are for MR.This is for an MRI. Technical specifications updated.
VISN 2: VA Healthcare Network Upstate New York528B54202528 SYRACUSE NYThe Tech Spec has several incomplete sections.Technical specifications updated.
VISN 2: VA Healthcare Network Upstate New York528B54202VISN 2: VA Healthcare Network Upstate New York528 SYRACUSE NYThis is a MRI.Correct, this is for an MRI. Technical specifications updated.
VISN 2: VA Healthcare Network Upstate New York528B57019VISN 2: VA Healthcare Network Upstate New York528 BATH NYThis is a Bone Density System.Confirmative - This is a Bone Density Unit.
VISN 2: VA Healthcare Network Upstate New York528B57019VISN 2: VA Healthcare Network Upstate New York528 BATH NY1h: Change to 18" to allow for fair competition
1l: Change to 778 lbs. to allow for fair competition1k. - Moved to value added section

1m. - Max equipment weight increased to 265 lbs.

5k. - Moved to value added section VISN 2: VA Healthcare Network Upstate New York 528B57020 VISN 2: VA Healthcare Network Upstate New York 528 BATH NY Request 1.k. Minimum Battery Life 60 mins moved to Value Add Section.

Request item 1.m. Maximum equipment weight be increased from 230lbs to 265lbs.

Request 5.k. Ability to enter standby mode or sleep mode be moved to Value Add Section. 1h - Requirment remaining at 24'' does not meet patient size requirements per FLX clinical standards 1l- Changed to 800lbs to allow for fair competition.

VISN 4: VA Stars & Stripes Healthcare Network529B52004VISN 4: VA Stars & Stripes Healthcare Network529 BUTLER PA1.m. Can the weight be raised to 290 lbs to increase competition?Technical specifications updated.
VISN 4: VA Stars & Stripes Healthcare Network529B52004VISN 4: VA Stars & Stripes Healthcare Network529 BUTLER PA6.j Can this Mitral Valve Navigator anaylysis package be moved to the Added Value section to increase competition?Technical specifications updated.
VISN 4: VA Stars & Stripes Healthcare Network529B52004VISN 4: VA Stars & Stripes Healthcare Network529 BUTLER PA6.k. Can this Cardiac 3D Quantification anaylysis package be moved to the Added Value section to increase competition?Technical specifications updated.
VISN 4: VA Stars & Stripes Healthcare Network529B52004VISN 4: VA Stars & Stripes Healthcare Network529 BUTLER PACan the minimum monitor size be expanded to 19 inches to increase competition?

Can the minimum monitor active size be expanded to 19 inches to increase competition?

Scanning Modes: d. Image Fusion Software. Please confirm the need for Fusion.

If Fusion is required, will it be needed for TP, TR, of both?

If Fusion is required, will it be required to be freehand or stabilized?

Is phantom for quality control testing a hard requirement or can it be a value add?

Can cardiac strain imaging be changed to a value add?

6. Analysis packages i. cardiovascular clinical - what procedures are being performed with this application?

j. mitral valve navigator - what procedures are being performed with this application?

k. cardiac 3D quantification - what procedures are being performed with this application?Technical specifications updated.
VISN 4: VA Stars & Stripes Healthcare Network529B52004VISN 4: VA Stars & Stripes Healthcare Network529 BUTLER PARequest item 1.g. Minimum Control Panel rotation of 720 degrees reduces to 350 degrees.
Request item 1.m. Maximum equipment weight of 240 lbs to be increased to 265lbs.Technical specifications updated.
VISN 7: VA Southeast Health Care Network5345B5007VISN 7: VA Southeast Health Care Network534 CHARLESTON SCPlease provide benchmark or matrixCompliance matrix is already listed in the solicitation, but both tech specs and matrix are attached for convenience.
VISN 7: VA Southeast Health Care Network534B52019VISN 7: Southeast Healthcare Network534 CHARLESTONWhat analysis packages do you need for Pain Management?Musculoskeletal Clinical and Procedural line items on tech specs should cover necessary Pain Management analysis packages
VISN 7: VA Southeast Health Care Network534B52019VISN 7: Southeast Healthcare Network534 CHARLESTONDo you need 3 of each transducer? If so do you want 9 transducers per machine?
a. L12-3: Arterial, Breast, Lung, Musculoskeletal, Nerve, Ophthalmic, PIV, Venous312-3
b. L19-5: Arterial, Lung, Musculoskeletal, Nerve, Ophthalmic, PIV, Superficial, Venous319-5
c. C10-3: Abdominal, Gynecology, Lung, Musculoskeletal, Nerve, Spine310-3
This should be a quantity of 2 transducers per type instead of 3, so the total should be 6 transducers for the order (3 for each machine)
VISN 7: VA Southeast Health Care Network534B52019VISN 7: VA Southeast Health Care Network534 CHARLESTON SCCan the minimum monitor size be expanded to 19 inches to increase competition?

Can the minimum battery life be changed to 1.5 hours to increase competiton?

Transducers: b. l19-5 - can the frequency range be reduced to 18 to increase competition? No, will need to keep minimum monitor size at 21 in

Yes, battery life can be changed to 1.5 hours

No, frequency needs to be higher (19-5) to achieve higher image resolution

VISN 7: VA Southeast Health Care Network534B52019VISN 7: VA Southeast Health Care Network534 CHARLESTON SCRequest item 1a. Minimum screen size of 21 in reduced to 19".No, will need to keep minimum monitor size at 21 in
VISN 10: VA Healthcare System of Ohio538B50002VISN 10: VA Healthcare System of Ohio538 CHILLICOTHE OH2.b. Minimum 1st detector size [in x in] - please confirm "Large 16x22.5". Is 17x17 acceptable?Yes
VISN 10: VA Healthcare System of Ohio538B50002VISN 10: VA Healthcare System of Ohio538 CHILLICOTHE OH1.Would you please provide us with CAD drawings for this room?This is a portable unit not specific to one room.
VISN 10: VA Healthcare System of Ohio538B50002VISN 10: VA Healthcare System of Ohio538 CHILLICOTHE OH1. Please change the generator size to 30kW to allow for full and fair competition.

2. Please change detector size to 17x17 to allow for full and fair competition.

3. Please remove tube and detector alignment software to allow full and fair competition.Technical specifications updated.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .