Pressure Transducers for Mu2e Equipment Cooling Water System.pdf
PDF 43 KB Posted
- Attached to
- Pressure Sensors
- Solicitation number
- 365416
About this file
This engineering specification from Fermi National Accelerator Laboratory details requirements for 10 radiation-resistant pressure transducers needed for the Mu2e experiment's equipment cooling water system. The transducers must measure gauge pressure with a range of 0-150 PSIG, have temperature compensation from 0-50°C, and maintain 1% FS accuracy or better.
The devices must withstand a 2Mrad/yr radiation environment for 10 years and operate in magnetic fields up to 600 gauss. Technical requirements include stainless steel wetted materials, mV/V output signal (preferred), and DIN rail mountable signal conditioning amplifiers producing 4-20mA output. Eight sensors require 70-meter radiation-resistant cables, while two need 45-meter cables. Responses are due by January 27, 2025, at 4:00 PM CST to Fermi Forward Discovery Group, LLC. The procurement falls under NAICS code 334519, with delivery required to Fermilab in Batavia, IL.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fermi National Accelerator Laboratory Engineering Specification Mechanical Engineering Department Pressure Transducers for Mu2e Equipment Cooling Water System 17 Dec 24 Revision
Number Text Classification Preamble
A.1 Fermilab seeks radiation resistant pressure transducers to use in a cooling water system for the Mu2e experiment.
Informational
A.2 Quantity of 10 pressure transducers will be used to measure the supply and return pressure of the equipment cooling water system.
Informational
Basic specifications
B.1 The transducer shall read gauge pressure. Requirement
B.2 The transducer shall have a range of 0 to 150 PSIG. Supplier may propose similar pressure ranges. Requirement
B.3 The transducer shall have a temperature compensated range of at least 0 to 50 °C. (32 to 122 °F) Requirement B.4 The transducer shall have a listed burst or over pressure. Requirement
Accuracy and Stability
C.1 The transducer shall have accuracy of 1% FS or better Requirement
Process Interface
D.1 A 1/4" Male VCR process connection is preferred. Suppliers may propose other connection types. Optional D.2 Wetted materials of stainless steel is preferred. Requirement
Electrical Interface
E.1 A pressure transducer with a mV/V output signal is preferred. Optional
E.2 Standard strain gage amplifier for signal conditioning shall be provided. Amplifier shall produce a 4 20mA analog output. Amplifier does not need to be radiation resistant. Shall be DIN rail mountable.
Requirement
E.3 Amplifier with 14 to 26Vdc power supply preferred. Requirement E.4 Standard electrical connection on pressure sensor. Optional
E.5 Radiation resistant cabling shall be provided. Quantity 8 sensors shall have a cable length of 70 meters.
Quantity 2 sensors shall have a cable length of 45 meters.
Requirement
E.6 Cabling shall be calibrated with pressure sensor for optimal accuracy. Requirement Environment
F.1 Device and cabling shall be able to endure a 2Mrad/yr environment for a duration of 10 years. Requirement
F.2 Device will be exposed to stray magnetic fields up to 600 gauss. Informational
F.3 It is desirable for the supplier to provide measurements or correction factors for deviations caused by the magnetic field.
Requirement