This document is an Asbestos Containing Materials (ACM) and Hazardous Materials Inspection Report prepared by Red Cedar Consulting for the City of Jackson, Michigan, concerning the property located at 329 W Franklin St. The inspection was conducted on April 10, 2025, to comply with United States Environmental Protection Agency (USEPA) and Occupational Safety and Health Administration (OSHA) requirements for demolition and renovation. The report details a comprehensive examination of a 2,147 square foot residential building, including seventeen samples collected from various materials such as vapor barrier, asphalt shingles, window glazing, drywall, joint compound, and linoleum. Laboratory analysis using Polarized Light Microscopy (PLM) was performed by APEX Research Inc. to determine the presence of asbestos.

The inspection revealed no asbestos-containing materials (ACM) in the building. However, hazardous materials were identified, including eight automobile tires located in the basement and building exterior, one 4' fluorescent light fixture with ballast in the northwest bedroom, and one 4' fluorescent bulb. The report provides detailed recommendations for proper removal and disposal of these hazardous materials, emphasizing the need to file a Notification of Intent to Renovate/Demolish with the Michigan Department of Environmental Quality-Air Quality Division at least 10 working days prior to any renovation or demolition activities. Red Cedar Consulting notes that while no ACM was detected, additional inspections may be required if suspect materials are encountered during future renovation or demolition processes.

View the file

Other files

File Type Posted
329_W._Franklin_St_-_Demolition.pdf PDF
Image_004.pdf PDF
329_W._Franklin-_Demolition_Special_Conditions.docx DOCX document
329_W_FRANKLIN-_Water_Sewer_Card.pdf PDF
CDBG_Additional_Forms.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.O. Box 13216 Lansing, MI 48901 Phone: 888.449.4566 Fax: 888.448.8739 www.redcedarconsulting.net

April 16, 2025

Mr. Brian Taylor City of Jackson Community Development Department Jackson, MI 49202

RE: Asbestos Containing Material and Hazardous Materials Inspection 329 W Franklin St. Jackson, MI 49201 Parcel ID: 4038600000

Dear Mr. Taylor:

Red Cedar Consulting has completed an asbestos-containing material (ACM) and hazardous materials inspection at 329 W Franklin St. Jackson, Michigan (Subject Property). This inspection was completed at the request of the City of Jackson to comply with the United States Environmental Protection Agency (USEPA) requirements for demolition and renovation set forth under the National Emissions Standards for Hazardous Air Pollutants (NESHAP, 40 CFR Part 61). This inspection was also completed to comply with the Occupational Safety and Health Administration (OSHA) Asbestos Standards for Construction (29 CFR 1926.1101) which limits employee exposure to asbestos.

SUBJECT PROPERTY

The Subject Property is comprised of a .13-acre residential parcel which contains an approximate 2,147 square foot residential building (the Building) with an unknown date of construction. The Building was constructed on a concrete basement with two aboveground floors. The exterior walls of the Building were finished with vinyl siding over wood lap while the roof was sealed with asphalt shingles. The Building can be further divided into a front entry, living room, dining room, kitchen, bath, and one bedroom on the first floor while the second floor contains four bedrooms and a bathroom. Please note, during the inspection the second floor was unable to be fully accessed due to the debris and unsafe conditions from previous fire damage. Partial access was available at all room thresholds and sampling was completed within these areas.

VISUAL INSPECTION AND SAMPLING

Asbestos Containing Materials Inspection

Darrell DeMasters of Red Cedar Consulting (Red Cedar), accredited State Of Michigan/EPA Asbestos Building Inspector (Accreditation Number A31159) who completed training per the Michigan Asbestos Workers Accreditation Act 440, completed an inspection of the Subject Property on April 10, 2025, for suspected asbestos containing building materials.

Project No.: 12-1027

This inspection, and subsequent sample collection was completed in accordance with the USEPA Asbestos Hazard Emergency Response Act (AHERA) (40 CFR Part 763) assessment and sampling protocol.

During the completion of the inspection, each area of the Subject Property was visually inspected for asbestos containing building materials (ACBM). Following the completion of the visual inspection, Red Cedar staff identified each suspect area of friable and non-friable ACBM and sorted them into one of three homogenous categories for sampling purposes. AHERA defines friable as a material that when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. A homogenous area is defined by OSHA as an area of surfacing, thermal system insulation (TSI) or miscellaneous material that is uniform in color and texture. Surfacing materials are most commonly found in sprayed-on, troweled-on or otherwise applied to surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural members. TSI refers to materials applied to pipes, fittings, boilers, ductwork, or other components to prevent heat loss or gain, or condensation. Any material that does not fall under the surfacing or TSI category, such as floor tile, drywall, and acoustical ceiling tile are placed into the miscellaneous materials category.

Following the completion of the visual inspection, Red Cedar staff identified the following materials as suspect ACBM:

• Vapor Barrier

• Asphalt Shingle

• Window Glazing

• Drywall and Joint Compound

• Linoleum

Red Cedar staff collected seventeen samples of suspect ACBM separated into six distinct homogenous groups for laboratory analysis. Samples were collected and submitted to APEX Research Inc.

Laboratories (APEX) (Accreditation Number 102118-0) for laboratory analysis. Analysis was completed utilizing polarized light microscopy (PLM) which is the Environmental Protection Agency (EPA) approved method for analysis of bulk materials for asbestos. PLM analysis completed pursuant to method (EPA 600/M4-82-020) identifies asbestos fiber bundles by the visual properties displayed when the sample is treated with various dispersion staining liquids. The laboratory report completed following the sample analysis indicates if asbestos is present, and at what percentage along with a description and percentage of other fibrous and non-fibrous materials and sample color. Chain-of-custody documentation was followed from sample collection through shipping and receiving of the samples at the designated laboratory. The documentation assures that samples will meet the quality assurance/quality control measures defined by AHERA. The laboratory analytical report prepared by APEX for the seventeen samples is included as Attachment A.

Hazardous Materials Inspection

On April 10, 2025 the Subject Property was also inspected for the presence of hazardous materials which include but are not limited to polychlorinated biphenyls (PCBs) and potential mercury containing equipment and any items or containers that may contain or be classified as a hazardous or regulated material. Each material, if identified, was documented along with the approximate location. Any materials identified as hazardous are included in Table 1.

INSPECTION RESULTS AND RECOMMENDATIONS

During the completion of the asbestos inspection, seventeen samples of suspect ACM were collected and are documented in Table 2 along with the Red Cedar sample number, description, friability, material type, ACM classification, sample location, material quantity and laboratory analytical results. A Site Diagram was prepared which provides the general building layout and sample locations and is included as Attachment B.

ACM, as defined by the USEPA NESHAP is “any material containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763 Section 1, Polarized Light Microscopy”.

Friable ACM is defined by NESHAP as any material containing more than 1 percent asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Friable ACM is a concern due to the ease of unintentionally disturbing the ACM which may result in “visible emissions” which is known as a Fiber Release Episode.

Non-friable asbestos-containing material is defined as “material containing more than 1 percent asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Non-friable ACMs are separated into Category I and Category II ACM. Category I ACM is any asbestos containing packing’s, gaskets, resilient floor coverings (vinyl floor tile and linoleum are examples of these) and asphalt roofing products. Category II ACM is stated by NESHAP as any material excluding Category I non-friable ACM such as drywall, plaster or fiberboard insulation.

Presumed Asbestos Containing Material

Presumed Asbestos Containing Materials (PACM) are suspect surfacing, TSI and miscellaneous materials found in buildings constructed prior to 1980 which are classified as and due to the age of the structure, are assumed to be ACM and do not require sample collection and analysis. OSHA dictates that PACM may be “rebutted” following a complete inspection pursuant to AHERA protocol.

No PACM was identified during the completion of this inspection. All suspect materials identified were sampled and analyzed for ACM.

Table 3 lists the location, material description, friability, condition, material type (surfacing, thermal or miscellaneous) and approximate quantity of all PACM documented at the Subject Property.

Table 4 provides a summary of all ACM documented at the Subject Property which includes the material location, description, and approximate quantity.

Friable ACM’s

No friable ACM’s were identified during the completion of this inspection.

Category I ACM

No Category I ACM was identified during the completion of this inspection.

Category II ACM

No Category II non-friable ACM was identified during the completion of this inspection.

RECOMMENDATIONS

Asbestos Containing Materials

No ACM was identified within the Building that would require abatement prior to demolition/renovation of the structure.

Please note: The location of samples obtained during this inspection were in a random fashion and areas that were not identified during this inspection may be damaged or have become damaged since the inspection was completed. If Category I or Category II friable materials are discovered prior to or during the demolition/renovation process, these materials must be abated prior to commencement of any demolition/renovation activities at the Subject Property.

Hazardous Materials

Hazardous Materials identified at the Subject Property and documented in Table 1 which require proper removal and disposal consist of the following items:

• Automobile Tires (8)

• 4’ Fluorescent Light (Fixture and Ballast Only) (1)

• 4’ Fluorescent Bulb (1)

REGULATORY REQUIREMENTS

A Notification of intent to Renovate/Demolish form must be filed with the Michigan Department of Environmental Quality- Air Quality Division at least 10 working days prior to any renovation or demolition activities at a site.

The Notification of Intent to Renovate/Demolish form must also be completed and submitted to the MIOSHA-Asbestos Program whenever demolition, encapsulation and/or renovation activities at a site involving greater than ten lineal feet and/or fifteen square feet of ACM will be completed.

Regulated asbestos containing materials per NESHAP (40 CFR Part 61) which falls into any of the following categories are ACM’s that must be removed prior to any renovation/demolition activities at the Subject Property.

• Friable asbestos material.

• Category I non-friable ACM that has become friable.

• Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

• Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of renovation or demolition operations.

Asbestos abatement should only be performed by a certified asbestos abatement contractor licensed to complete abatement work. The contractor must also follow the standards and requirements set forth per the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR Part 61).

Additional information regarding the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR Part 61) can be obtained by contacting the associated agency below.

NESHAP Asbestos Program MIOSHA-CSHD-Asbestos Program Department of Environmental Quality State of Michigan Phone: 517-284-6777 Phone: 517-284-7680 Email: asbestos@michigan.gov

DISCLAIMER

Red Cedar Consulting performed destructive testing methods in an attempt to access and inspect all areas of the Building. Unfortunately, due to the age of construction along with multiple additions/renovations that may have been completed on the Building, additional inspections may be required if suspect ACM material not documented within this report is encountered during renovation/demolition activities.

This report was prepared at the request and for exclusive use by the City of Jackson and may not be reproduced or sold without written permission from Red Cedar Consulting.

We appreciate the opportunity to provide the requested services. Please contact us at (888) 449-4566 with any questions or concerns.

Sincerely, Red Cedar Consulting

Aaron Paquet

Michigan/EPA Certified Asbestos Building Inspector (A30955)

©2025 Red Cedar Consulting, LLC.

Attachment A

APEX Research Laboratory Analytical Results

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Report To: ARI Report # 25-117034 Mr. Aaron Paquet Date Collected: 04/10/25 Red Cedar Consulting Date Received: 04/11/25 P.O. Box 13216 Date Analyzed: 04/11/25 Lansing, MI 48901 Date Reported: 04/11/25

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117034 - 01 Asbestos Present: NO Cellulose - 90%

Cust. #: FS-HM-01A No Asbestos Observed Other - 10% Material: Vapor Barrier Location:

Appearance: black,fibrous,homogenous Layer: 1 of 1

Lab ID #: 117034 - 02 Asbestos Present: NO Cellulose - 90% Cust. #: FS-HM-01B No Asbestos Observed Other - 10% Material: Vapor Barrier Location:

Appearance: black,fibrous,homogenous Layer: 1 of 1

Lab ID #: 117034 - 03 Asbestos Present: NO Cellulose - 30% Cust. #: FS-HM-02A No Asbestos Observed Other - 70% Material: Asphalt Shingle Location:

Appearance: black,fibrous,homogenous Layer: 1 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Liability limited to cost of analysis.

Project: 329 W. Franklin St.

NVLAP Lab Code 102118-0

APEX Research Inc., 7717 Kensington Ct., Brighton, MI 48116

(734) 449-9990, Fax (734) 449-9991 Page 1 of 6

Report To: ARI Report # 25-117034 Mr. Aaron Paquet Date Collected: 04/10/25 Red Cedar Consulting Date Received: 04/11/25 P.O. Box 13216 Date Analyzed: 04/11/25 Lansing, MI 48901 Date Reported: 04/11/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117034 - 03a Asbestos Present: NO Cellulose - 60%

Cust. #: FS-HM-02A No Asbestos Observed Other - 40% Material: Tar Paper Location:

Appearance: black,fibrous,homogenous Layer: 2 of 2

Lab ID #: 117034 - 04 Asbestos Present: NO Cellulose - 30% Cust. #: FS-HM-02B No Asbestos Observed Other - 70% Material: Asphalt Shingle Location:

Appearance: black,fibrous,homogenous Layer: 1 of 2

Lab ID #: 117034 - 04a Asbestos Present: NO Cellulose - 60% Cust. #: FS-HM-02B No Asbestos Observed Other - 40% Material: Tar Paper Location:

Appearance: black,fibrous,homogenous Layer: 2 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 2 of 6

Report To: ARI Report # 25-117034 Mr. Aaron Paquet Date Collected: 04/10/25 Red Cedar Consulting Date Received: 04/11/25 P.O. Box 13216 Date Analyzed: 04/11/25 Lansing, MI 48901 Date Reported: 04/11/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117034 - 05 Asbestos Present: NO Other - 100%

Cust. #: FS-HM-03A No Asbestos Observed Material: Window Glazing Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 117034 - 06 Asbestos Present: NO Other - 100% Cust. #: FS-HM-03B No Asbestos Observed Material: Window Glazing Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 117034 - 07 Asbestos Present: NO Other - 100% Cust. #: FS-HM-03C No Asbestos Observed Material: Window Glazing Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 3 of 6

Report To: ARI Report # 25-117034 Mr. Aaron Paquet Date Collected: 04/10/25 Red Cedar Consulting Date Received: 04/11/25 P.O. Box 13216 Date Analyzed: 04/11/25 Lansing, MI 48901 Date Reported: 04/11/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117034 - 08 Asbestos Present: NO Other - 100%

Cust. #: FS-HM-03D No Asbestos Observed Material: Window Glazing Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: 117034 - 09 Asbestos Present: NO Cellulose - 20% Cust. #: FS-HM-04A No Asbestos Observed Other - 80% Material: Drywall Location:

Appearance: white,fibrous,homogenous Layer: 1 of 2

Lab ID #: 117034 - 09a Asbestos Present: NO Other - 100% Cust. #: FS-HM-04A No Asbestos Observed Material: Joint Compound Location:

Appearance: white,nonfibrous,homogenous Layer: 2 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 4 of 6

Report To: ARI Report # 25-117034 Mr. Aaron Paquet Date Collected: 04/10/25 Red Cedar Consulting Date Received: 04/11/25 P.O. Box 13216 Date Analyzed: 04/11/25 Lansing, MI 48901 Date Reported: 04/11/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117034 - 10 Asbestos Present: NO Cellulose - 20%

Cust. #: FS-HM-04B No Asbestos Observed Other - 80% Material: Drywall Location:

Appearance: white,fibrous,homogenous Layer: 1 of 2

Lab ID #: 117034 - 10a Asbestos Present: NO Other - 100% Cust. #: FS-HM-04B No Asbestos Observed Material: Joint Compound Location:

Appearance: white,nonfibrous,homogenous Layer: 2 of 2

Lab ID #: 117034 - 11 Asbestos Present: NO Cellulose - 2% Cust. #: FS-HM-05A No Asbestos Observed Other - 98% Material: Cream Linoleum Location:

Appearance: grey,fibrous,nonhomogenous Layer: 1 of 1

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 5 of 6

Report To: ARI Report # 25-117034 Mr. Aaron Paquet Date Collected: 04/10/25 Red Cedar Consulting Date Received: 04/11/25 P.O. Box 13216 Date Analyzed: 04/11/25 Lansing, MI 48901 Date Reported: 04/11/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117034 - 12 Asbestos Present: NO Other - 100%

Cust. #: FS-HM-05B No Asbestos Observed Material: Cream Linoleum Location:

Appearance: beige,nonfibrous,homogenous Layer: 1 of 1

Lab ID #: Asbestos Present:

Cust. #:

Material:

Location:

Appearance:

Layer: of

Lab ID #: Asbestos Present:

Cust. #:

Material:

Location:

Appearance:

Layer: of

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 6 of 6

Report To:

Mr. Aaron Paquet

ARI Report # 25-117111 Date Collected:

Red Cedar Consulting Date Received: 04/16/25 P.O. Box 13216 Date Analyzed: 04/16/25 Lansing, MI 48901 Date Reported: 04/16/25

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117111 - 01 Asbestos Present: NO Other - 100%

Cust. #: FS-HS-01A No Asbestos Observed Material: Plaster Finish Coat Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 117111 - 01a Asbestos Present: NO Hair - 2% Cust. #: FS-HS-01A No Asbestos Observed Other - 98% Material: Plaster Base Coat Location:

Appearance: grey,fibrous,homogenous Layer: 2 of 2

Lab ID #: 117111 - 02 Asbestos Present: NO Other - 100% Cust. #: FS-HS-01B No Asbestos Observed Material: Plaster Finish Coat Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Liability limited to cost of analysis.

Project: 329 W. Franklin St.

NVLAP Lab Code 102118-0 APEX Research Inc., 7717 Kensington Ct., Brighton, MI 48116

(734) 449-9990, Fax (734) 449-9991 Page 1 of 4

04/15/25

Report To:

Mr. Aaron Paquet

ARI Report # 25-117111 Date Collected:

Red Cedar Consulting Date Received: 04/16/25 P.O. Box 13216 Date Analyzed: 04/16/25 Lansing, MI 48901 Date Reported: 04/16/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117111 - 02a Asbestos Present: NO Hair - 2%

Cust. #: FS-HS-01B No Asbestos Observed Other - 98% Material: Plaster Base Coat Location:

Appearance: grey,fibrous,homogenous Layer: 2 of 2

Lab ID #: 117111 - 03 Asbestos Present: NO Other - 100% Cust. #: FS-HS-01C No Asbestos Observed Material: Plaster Finish Coat Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 117111 - 03a Asbestos Present: NO Hair - 2% Cust. #: FS-HS-01C No Asbestos Observed Other - 98% Material: Plaster Base Coat Location:

Appearance: grey,fibrous,homogenous Layer: 2 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0 APEX Research Inc., 7717 Kensington Ct., Brighton, MI 48116

(734) 449-9990, Fax (734) 449-9991 Page 2 of 4

Report To:

Mr. Aaron Paquet

ARI Report # 25-117111 Date Collected:

Red Cedar Consulting Date Received: 04/16/25 P.O. Box 13216 Date Analyzed: 04/16/25 Lansing, MI 48901 Date Reported: 04/16/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117111 - 04 Asbestos Present: NO Other - 100%

Cust. #: FS-HS-01D No Asbestos Observed Material: Plaster Finish Coat Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 117111 - 04a Asbestos Present: NO Hair - 2% Cust. #: FS-HS-01D No Asbestos Observed Other - 98% Material: Plaster Base Coat Location:

Appearance: grey,fibrous,homogenous Layer: 2 of 2

Lab ID #: 117111 - 05 Asbestos Present: NO Other - 100% Cust. #: FS-HS-01E No Asbestos Observed Material: Plaster Finish Coat Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0 APEX Research Inc., 7717 Kensington Ct., Brighton, MI 48116

(734) 449-9990, Fax (734) 449-9991 Page 3 of 4

Report To:

Mr. Aaron Paquet

ARI Report # 25-117111 Date Collected:

Red Cedar Consulting Date Received: 04/16/25 P.O. Box 13216 Date Analyzed: 04/16/25 Lansing, MI 48901 Date Reported: 04/16/25

Project: 329 W. Franklin St.

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 117111 - 05a Asbestos Present: NO Hair - 2%

Cust. #: FS-HS-01E No Asbestos Observed Other - 98% Material: Plaster Base Coat Location:

Appearance: grey,fibrous,homogenous Layer: 2 of 2

Lab ID #: Asbestos Present:

Cust. #:

Material:

Location:

Appearance:

Layer: of

Lab ID #: Asbestos Present:

Cust. #:

Material:

Location:

Appearance:

Layer: of

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0 APEX Research Inc., 7717 Kensington Ct., Brighton, MI 48116

(734) 449-9990, Fax (734) 449-9991 Page 4 of 4

Attachment B Figure 1 Site Diagram

Figure 1a Site Diagram

Note: Figure created by Red Cedar Consulting Asbestos Sample Locations 329 W Franklin St.

-Not To Scale- Jackson, MI

Figure 1b Site Diagram

Note: Figure created by Red Cedar Consulting Asbestos Sample Locations 329 W Franklin St.

-Not To Scale- Jackson, MI

Tables

Table 1 - Summary of Hazardous Materials, 329 W Franklin St. Jackson, Michigan

Hazardous Materials Description and Location

Location Material Description Quantity

Basement Automobile Tires 3

Building Exterior Automobile Tires 5

NW Bedroom 4’ Fluorescent Light (Fixture and Ballast Only) 1

NW Bedroom 4’ Fluorescent Bulb 1

Table 2 - Summary of Sample Descriptions and Asbestos Laboratory Results, 329 W Franklin St. Jackson, Michigan

Sample Number Sample Description Friable Material

Type Material

Classification

% Asbestos Laboratory

Result Sample Location Approx. Material

Quantity

FS-HM-01A Vapor Barrier No M Category I ND Building Exterior NA

FS-HM-01B Vapor Barrier No M Category I ND Building Exterior NA

FS-HM-02A Asphalt Shingle Yes M Category II ND/ND Building Exterior NA

FS-HM-02B Asphalt Shingle Yes M Category II ND/ND Building Exterior NA

FS-HM-03A Window Glazing No M Category I ND Dining NA

FS-HM-03B Window Glazing No M Category I ND Living NA

FS-HM-03C Window Glazing No M Category I ND 2nd Fl. NW Bedroom NA

FS-HM-03D Window Glazing No M Category I ND 2nd Fl. NE Bedroom NA

FS-HM-04A Drywall and Joint Compound No M Category I ND/ND Dining Ceiling NA

FS-HM-04B Drywall and Joint Compound No M Category I ND/ND Living Wall NA

FS-HM-05A Cream Linoleum Yes M Category II ND Kitchen NA

FS-HM-05B Cream Linoleum Yes M Category II ND Kitchen NA

FS-HS-01A Plaster No S Category II ND/ND Living NA

FS-HS-01B Plaster No S Category II ND/ND Living NA

FS-HS-01C Plaster No S Category II ND/ND Kitchen NA

FS-HS-01D Plaster No S Category II ND/ND Stairway NA

FS-HS-01E Plaster No S Category II ND/ND 2nd Floor NA

Notes:

Material Types Abbreviations

M = Miscellaneous building material NQ = Not quantified TSI = Thermal System Insulation NA = Not Analyzed S = Surfacing Material ND = Not detected. Laboratory result is less than 1 % asbestos PC = Point Count Analysis lin. ft. = linear feet CH = Chrysotile Asbestos sq. ft. = square feet

Asbestos Containing Material (ACM) is defined as any material containing more than 1 percent asbestos as determined utilizing Polarized Light Microscopy.

Table 3 - Summary of Presumed Asbestos Containing Materials, 329 W Franklin St. Jackson, Michigan

Asbestos Containing Material Description and Location

Location Material Description Friable Condition Material Type Approx. Quantity

No Presumed Asbestos Containing Materials Identified

Notes:

Material Types Abbreviations

M = Miscellaneous building material lin. ft. = linear feet TSI = Thermal System Insulation sq. ft. = square feet S = Surfacing Material

Table 4 - Summary of All Asbestos Containing Materials, 329 W Franklin St. Jackson, Michigan

Exterior - Asbestos Containing Materials

Location Material Description Friable Approx. Quantity

No Asbestos Containing Materials Identified

Notes:

Abbreviations lin. ft. = linear feet

sq. ft. = square feet

Shaded/Bolded = Friable ACM and any Category I and Category II non-friable ACM that has a high probability of becoming crumbled, pulverized, or reduced to powder by the demolition or renovation activities that must be properly abated prior to commencement of any demolition/renovation activities.

Demolition/renovation activities completed with intact Category I non-friable ACM are regulated by OSHA and must be completed following the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) which limits employee exposure to asbestos.

Please note that a Negative Pressure Enclosure must be utilized during abatement when Site Conditions Warrant. Examples of these conditions include the abatement of Plaster and Vermiculite insulation, HVAC Duct Wrap in Poor Condition, and Air-O-Cell/Mag Pipe Wrap. Conditions outside of these should be assessed on a case by case basis during the Asbestos Abatement Contractors site walk and Work Plan Preparation.

File details come from the government source that posted it. Updated .