3198 Addendum No 01 .pdf
PDF 13 MB Posted
- Solicitation number
- 3198
- Issued by
- Hinds County, Weir Town, Mississippi
About this file
This Addendum No. 1 is issued by Hinds Community College for the Federal Aid Project STP-0211-00(015) LPA 107143/701000, involving pedestrian and sidewalk improvements. The addendum includes updates to the project documents such as replacing the table of contents, adding pre-bid meeting minutes and Q&A, replacing specific special provisions and plan sheets, and modifying Section 905 bid sheets. The project involves improvements to the Hinds Community College campus in Raymond, Mississippi, with work to be performed along Hinds Boulevard, East Main Street, and Bill Oakes Drive. The contract time is set at 105 working days, and the project includes various construction activities such as removing existing pavement, installing new sidewalks, curbs, lighting, and traffic control measures.
The bid includes specific line items for different construction elements, with a 5% Disadvantaged Business Enterprise (DBE) goal. The project will require various materials and installations, including concrete sidewalks, detectable warning panels, lighting assemblies (LED bollards and area lights), electrical work, and traffic control items. There are two add-option items: one for LED area lights and another for LED bollards, which the Local Public Agency (LPA) will decide whether to include after bid opening. The project is funded through a federal aid program, and bidders must submit a bid bond or certified check for 5% of the total bid. The contract will be awarded to the lowest responsible bidder, with the ability to adjust certain items like the LED bollards and area lights after bid evaluation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3198 Drawings Part 3.pdf | ||
| 3198 Drawings Part 1.pdf | ||
| 3198 Project Manual.pdf | ||
| 3198 Drawings Part 2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
08/06/2020
SECTION 905 PROPOSAL (Continued)
I (We) further propose to execute the attached contract agreement (Section 902) as soon as the work is awarded to me (us), and to begin and complete the work within the time limit(s) provided for in the Specifications and Advertisement. I (We) also propose to execute the attached contract bond (Section 903) in an amount not less than one hundred (100) percent of the total of my (our) part, but also to guarantee the excellence of both workmanship and materials until the work is finally accepted.
I (We) enclose a certified check, cashier's check or bid bond for five percent (5%) of the total bid and hereby agree that in case of my (our) failure to execute the contract and furnish bonds within Ten (10) days after notice of award, the amount of this check (bid bond) will be forfeited to the Local Public Agency as liquidated damages arising out of my (our) failure to execute the contract as proposed. It is understood that in case I am (we are) not awarded the work, the check will be returned as provided in the Specifications.
Bidder acknowledges receipt of and has added to and made a part of the proposal and contract documents the following addendum (addenda):
ADDENDUM NO. DATED ADDENDUM NO. DATED
ADDENDUM NO DATED ADDENDUM NO. DATED
TOTAL ADDENDA:
(Must agree with total addenda issued prior to opening of bids)
Respectfully Submitted, DATE
Contractor
BY
Signature
TITLE
ADDRESS
(To be filled in if a corporation)
Our corporation is chartered under the Laws of the State of and the names, titles and business addresses of the executives are as follows:
President Address
Secretary Address
Treasurer Address
The following is my (our) itemized proposal.
Revised 11/2008
ADDENDUM NO. 1:
a. REPLACE: Table of Contents
b. ADD: Pre-Bid Meeting Minutes NTB
c. ADD: Pre-Bid Q&A NTB
d. REPLACE: Special Provision 907-259-1
e. REPLACE: Section 905, Page 2 with this revised page dated: 08/06/2020
f. REPLACE: Section 905, Bid Sheets
g. REPLACE: Plan Sheet Nos. 2, 8, 9, 12, 14, 15, 29, 30, 31 , 32, 33
h. ADD: Plan Sheet Nos. 33.1, 33.2
1 08/06/2020
HINDS COMMUNITY COLLEGE
LOCAL PUBLIC AGENCY DIVISION
TABLE OF CONTENTS
PROJECT: STP-0211-00(015)/LPA/107143-701000 – Hinds County
Section 901 – Advertisement Bidders Check List
Section 904 – Notice to Bidders #1 Governing Specifications #1A Designated Owner and Engineer #2 Status of ROW #3 Final Cleanup #9 Federal Bridge Formula #13 Safety Edge #28 Fuel and Material Adjustments #113 Tack Coat #445 Mississippi Agent or Qualified Nonresident Agent #516 Errata and Modifications to the 2017 Standard Specifications #757 Additional Erosion Control Requirements #977 DUNS Requirement for Federal Funded Projects #1225 Early Notice to Proceed #1546 Advancement of Materials #1878 Storm Water Discharge Associated w/Construction Activities (≥1 and <5 acres) #2061 Reflective Sheeting for Signs #2172 App for Storm Water Reports #2206 MASH Compliant Devices #2214LPA Disadvantaged Business Enterprises in Federal-Aid Highway Construction #2273 Mississippi Special Fuel Tax Law #2689LPA Asphalt Smoothness Requirement #4303 Add Option Bidding #5865LPA Sampling and Testing of Concrete on Small LPA Projects #5866LPA Payroll Requirements #6000LPA Requirements for Traffic Control Personnel #7001 Contract Time #7200 Specialty Items #8000 Pre-Bid Meeting Minutes #8001 Pre-Bid Questions and Answers
Section 906 – Required Federal Contract Provisions FHWA 1273, with Supplements County Wages
Section 907 – Special Provisions 907-102-4 LPA Bidding Requirements and Conditions 907-107-2 Contractor’s Erosion Control Plan 907-109-1 Measurement and Payment 907-259-1 Miscellaneous Site Lighting 907-608-2 Detectable Warning Panels 907-611-1 Brick Pavers 907-630-1 Remove and Reset Signs 907-636-2 Electrical Cable 907-701-1 Hydraulic Cement
907-702-4 Bituminous Material 907-703-1 Gradation 907-705-1 Stone Riprap 907-707-1 Flexible Plastic Gaskets 907-708-2 Reinforced Concrete Pipe 907-711-2 Plain Steel Wire 907-720-2 Acceptance Procedure for Glass Beads 907-721-1 Materials for Signing
Construction Progress Schedule
Section 905 – Proposal Section 905 – Proposal Bid Sheets Certificate of Performance - Prior Federal Aid Contracts Certificate Regarding Non-Collusion, Debarment and Suspension (2) SAM.GOV Registration and DUNS Number
Section 902 – Local Public Agency Contract Section 903 – Local Public Agency Contract Bond Forms Executive Compensation Certification Guideline for Federal Spending Transparency Form OCR-481-LPA (3) Form OCR-485-LPA (3)
(REVISIONS TO THE ABOVE WILL BE INDICATED ON THE SECOND SHEET OF SECTION 905 AS ADDENDA)
08/06/2020 1:32 PM
MISSISSIPPI DEPARTMENT OF TRANSPORTATION
SUPPLEMENT TO NOTICE TO BIDDERS NO. 8000
DATE: 08/06/2020
SUBJECT: Pre-Bid Meeting Minutes
PROJECT: STP-0211-00(015)LPA/ 107143/701000
A pre-bid meeting was held at 10:00 A.M. July 28, 2020 at the Physical Plant Conference Room, Physical Plant and Auxiliary Services Building, 505 East Main Street, Raymond, Mississippi.
Attendees:
Name: Firm:
Ron McMaster Jr. McMaster and Associates Cole Farris McMaster and Associates Andrew Heard Hemphill Construction Ron Fender CDFL Clark Wells CDFL Josh Tillery MDOT Bill Campbell Hinds Community College Jesse Jones Hinds Community College Jason Pope Hinds Community College
Items discussed are as follows:
• Attendance passed by Bill Campbell.
• Ron McMaster chaired and called meeting to order.
• Dr. Clyde Muse has retired, and the new president of HCC is Dr. Stephen Vacik (Chief LPA
Officer)
• An overall summary of the project scope was given, with reference to the contract documents and final plans for complete scope of work
• Reference to Proposal. Unit price bid schedule awarded to lowest bidder.
• Reference to NTB 4303. The project has one add-option that includes the LED bollard and area lights. Project to be awarded to lowest total bidder. LPA will decide if add-option is to be removed after bid.
• MDOT has oversight of the project and can inspect at any time.
- Josh Tillery stated that he intends to visit the project site periodically.
• Governing specifications are the MDOT “Red Book” and special provisions included in the contract documents, with reference to NTB 01
• Existing utilities are shown on the plans, with reference to NTB 02.
- ATT has stated that their underground line along Hinds Blvd. is still in place but “dead”.
Their service has been relocated to the overhead poles
- Entergy has been notified and are in the engineering phase of relocation.
- It is expected that Entergy will have their poles relocated prior to construction, however it is not certain at this time.
• Contract time is 105 working days, with reference to NTB 7001
• No work outside of the scope of the executed contract is to be performed without a supplemental agreement. MDOT approval is required. Mississippi Transportation Commission approval may be required depending on the dollar amount.
• All bid addenda must be acknowledged on the proposal or the bid will be disqualified.
• All bid questions shall be submitted to McMaster and Associates via email
• Last day for questions is July 31, at 5:00 p.m. central time. Answers will be included as a formal addendum. The last addendum will be issued no later than August 6, at 5:00 p.m.
• Bid opening August 11, at 10:00 a.m. at Fountain Hall Room 208. Bids will be open and read aloud
• Required bid submittals are outlined in the bidder’s checklist and proposal. Reference the bid form and instructions to bidders for additional requirements.
• The required DBE goal is 5%
• All bids must be accompanied by bid security in the form of a certified check, cashier’s check or bid bond made payable to the LPA for no less than 5% of the total amount of the bid.
• Bids may be submitted via hand delivery, mailing, or electronic submission.
• Liquidated damages will be assessed at the maximum rate per the Red Book, based on the total contract amount.
• All bidders should familiarize themselves with and have a detailed understanding of the project site. Any potential bidders should check in with Bill Campbell or Jesse Jones when arriving on campus to examine the project site, then check out when leaving campus.
• Question and Answer Period
- Ron Fender discussed the electrical items as shown in the plans.
- Clark Wells discussed the architectural items as shown in the plans.
- Physical samples of all architectural materials are to be submitted to the Architect for review and approval.
- The new decorative campus entrance signs are to be similar in appearance to the existing masonry wall at the southwest corner of Hinds Blvd. and East Main St.
- Josh Tillery reminded the contractors to carefully review the pay items, footnotes, and details - since several pay items lump many different types of work together.
- Andrew Heard stated that maintaining the traffic control plan along East Main Street would be difficult since it is a two-lane road and the scope of work required in the area is extensive. He asked if the traffic control plan could possibly be revised to include a road closure or one-way traffic.
- The group discussed the traffic control plan in detail and concluded that it needed to be studied further with a possible modification via addendum
• Meeting was adjourned
SUPPLEMENT TO NOTICE TO BIDDERS NO. 8001
DATE: 08/06/2020
SUBJECT: Questions and Answers
PROJECT: STP-0211-00(015)LPA/ 107143/701000
1. The quantities for bid items 1030 & 1040 shown on the bid form do not match the quantities shown on Plan Sheet 4002. Which is correct?
Refer to Addendum No. 01 for updated quantities.
2. There is no fixture schedule in the plans. There are some fixtures listed in Special Provision No. 907-259-1 Miscellaneous Site Lighting, but the LED Area Lights are not included and the item number for the lighted bollards does not match the bid form.
Refer to Addendum No. 01 for revised SP 907-259-1 that includes fixture cutsheets.
SPECIAL PROVISION NO. 907-259-1
DATE: 08/04/2020
CODE: (SP)
SUBJECT: Miscellaneous Site Lighting
Section 907-259, Miscellaneous Site Lighting, is hereby added to and made a part of the 2017 Edition of the Mississippi Standard Specifications for Road and Bridge Construction as follows.
SECTION 907-259 - MISCELLANEOUS SITE LIGHTING
907-259.01--Description. This item shall consist of installing Lighted Bollards, Sign Lights, Weatherproof GFCI Receptacles, and Pedestrian Scale Area Lights, each complete in place with light source, in accordance with these Specifications and in reasonably close conformity with the locations , lines, grades, configurations, dimensions and other requirements shown on the plans or established.
907-259.02--Materials. Unless otherwise stipulated, the materials used in this construction, in addition to the general requirements of these specifications and the plans, shall conform to the provisions and requirements prescribed in the sections of the Standard Specifications for the several items which constitute the complete structure.
All items will require approval by the Engineer from the manufacturer. The Contractor shall submit six (6) copies of brochures or shop drawings for approval prior to ordering manufactured items. Other items may require testing as directed by the Engineer.
A. Lighted Bollards (Fixture B): Lighted Bollard shall be Model Number LBLCO-604, as manufactured by Forms + Surfaces. It shall be fabricated from 6” diameter tubular stainless steel. It shall have 360 degree light distribution with a custom shield with Owner-provided graphics. The lighting source shall be LED, 4000K CCT with an output of 1,500 lumens, minimum. The voltage and single fuse protection shall accommodate the available voltage on site. Color shall have a black texture finish, factory applied.
B. Sign Lights (Fixture C): Sign Lights shall be Model Number FSL-7L-25W-4K-W-U-K-BL, as manufactured by Hubbell Outdoor Lighting. It shall be small form factor flood. It shall have wide beam light distribution. The lighting source shall be LED, 4000K CCT with an output of 2,400 lumens, minimum. Provide and install concrete base with hardware for knuckle mount 4” above finished grade. The voltage and single fuse protection shall accommodate the available voltage on site. Color shall have a black texture finish, factory applied.
C. Weatherproof GFCI Receptacles: Weatherproof GFCI receptacle shall be commercial specification grade 20A 125V GFCI receptacle(s) as manufactured by Hubbell or other accepted models by Pass & Seymour, Leviton or approved equal. Color shall be black and verified with Project Engineer.
S. P. No. 907-259-1 -- Cont' d. -2-
D. Pedestrian Scale Area Lights (Fixture A): Pedestrian Scale Area Lights shall be Model
Number XLM3 PT 3 LED SS NW UE BLK, as manufactured by LSI Industries, Inc. It shall be post-top mounted. It shall have Type 3 light distribution. The lighting source shall be LED, 4000K CCT with an output of 5,900 lumens, minimum. The voltage and single fuse protection shall accommodate the available voltage on site.
907-259.03--Construction Requirements. The Contractor shall provide and install miscellaneous site lighting in accordance with the drawings, special provisions, and the standard specifications. All work shall be performed in a good workmanlike manner, to the satisfaction of the Engineer.
907-259.04--Method of Measurement. Miscellaneous site lighting of the type specified will be measured by the unit quantity per each.
907-259.05--Basis of Payment. Miscellaneous site lighting, measured as prescribed above, shall be paid for at the contract unit price bid per each (or included in other lump sum bid items per plans), which price shall be full compensation for furnishing all materials and supplies; for performing all work necessary for each completed unit; and for all equipment, tools, labor and incidentals necessary to complete the work.
Payment will be made under:
907-683-PP101: Lighting Assembly, Per Plans, LED Bollard, Including Base - per each
907-683-PP101:
Lighting Assembly, Per Plans, LED Area Light, Pedestrian Scale, Including Base
- per each
907-259-D001 Lighting Assembly, Sign Lighting, LED Linear Flood Light, Including Base - per each
GFCI Receptacles are included in the lump sum bid item:
L00092: 907-
611-PP504
Monument Sign, Per Plans, Decorative Campus Entrance Sign, with LED Panel
- lump sum
© 2016
LSI INDUSTRIES INC.
Project Name Fixture Type
Catalog #
10/2416
SMARTTEC™ - LSI drivers feature integral sensor which reduces drive current, when ambient temperatures exceed rated temperature.
ENERGY SAVING CONTROL OPTIONS - DIM - 0-10 volt dimming enabled with controls by others. BLS - Bi-level switching responds to external line voltage signal from separate 120- 277V controller or sensor (by others), with low light level decreased to 30% maximum drive current.
LEDS - Select high-brightness LEDs in Cool White (5000K) or Neutral White (4000K) color temperature, 70CRI.
DISTRIBUTION/PERFORMANCE - Types 3, FT, and 5. Exceptional uniformity creates bright environment at lower light levels. Improved backlight cutoff minimizes light trespass.
HOUSING - One piece housing/support frame is die-cast aluminum. Post top access cover and support arms are die-cast aluminum. Housing is sealed with an extruded silicone gasket.
HOUSING TOP CAP - Removable spun aluminum cap/driver enclosure is retained by captive stainless steel fasteners and safety cables. Housing and top cap interface is sealed with a one-piece extruded silicone gasket. Tool-less entry option is available.
SEALED OPTICAL UNIT - Lens is clear, flat tempered glass, sealed to aluminum optics housing.
Pressure stabilizing breather allows super-tight protection while preventing temperature cycling from building up internal pressures and vacuums that can stress optical unit seals and components.
FASTENERS - All exposed fasteners are black oxide coated stainless steel. Internal fasteners are stainless steel or zinc electroplated steel.
ELECTRICAL - Terminal block for attachment of incoming primary wiring is supplied. Two-stage surge protection (including separate surge protection built into electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal voltage power supply 120-277VAC (50/60Hz input), 347VAC and 480VAC. Optional button-type photocells (PCI) are available in 120, 208, 240, 277 or 347 volt (supply voltage must be specified).
DRIVER - Available in Super Saver (SS) and High Output (HO) drive currents (Drive currents are factory programmed). State-of-the-art driver technology designed specifically for LSI LED light sources provides unsurpassed system efficiency. Components are fully encased in potting material for moisture resistance. Driver complies with IEC and FCC standards.
OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F).
MOUNTING - Post Top and Wall mounting available. Pole selection information shown under fixture drawings.
FINISH - Fixtures are finished with LSI’s DuraGrip® polyester powder coat finishing process.
The DuraGrip finish withstands extreme weather changes without cracking or peeling.
WARRANTY - LSI LED fixtures carry a limited 5-year warranty.
PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed photometric data.
LISTING - Listed to U.S. and Canadian safety standards. Suitable for wet locations.
This product, or selected versions of this product, meet the standards listed below. Please consult factory for your specific requirements.
wet location
ARRA
Funding Compliant
Fixtures comply with ANSI C136.31-2010 American National Standard for Roadway Lighting Equipment - Luminaire Vibration 1.5G requirements.
LED LEXINGTON DECORATIVE AREA LIGHTS (XLXM3)
US patent 782456, 7952293, & 8432108 and US & Int’l. patents pending
Also available in traditional light sources
Type 3 Type FT Type 5
SS
HO
SS
HO
Co ol
W hi te
LIGHT OUTPUT - XLXM3
Lumens (Nominal)
# of LEDS
Ne ut ra l
W hi te 64
POST TOP MOUNT
LED Chips are frequently updated therefore values may increase.
Watts (Nominal) rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight
Owner Text Box
© 2016
LSI INDUSTRIES INC.
Project Name Fixture Type
Catalog #
10/2416
LED LEXINGTON DECORATIVE AREA LIGHTS (XLXM3)
TYPICAL ORDER EXAMPLE:
Prefix Mounting
Style
LUMINAIRE ORDERING INFORMATION
Input Voltage Finish Options
PT - Post Top BRZ – Bronze BLK – Black PLP – Platinum Plus WHT – White SVG - Satin Verde
Green GPT - Graphite MSV - Metallic Silver
FOOTNOTES:
1- DIM and BLS cannot be ordered together.
2- Order poles with 3" reduced drilling pattern. For PT mounting configurations other than D180, consult factory. Order one bracket per fixture.
XLXM3 PT 5 LED HO CW UE MSV PCI120
Accessories
Button Type Photocells PCI 120 - 120v PCHV208-277 - 208-277v PCI 347 - 347v TE - Tool-less Entry DIM - 0-10V Dimming (from external signal)1
BLS - Bi-level Switching (from external 120-277V signal)1
WM - Wall Mount BK MPT BO4 - Medium Bolt on Bracket (for PT 180)
For 4” Dia. Round Poles2
BK MPT BO5 - Medium Bolt on Bracket (for PT 180) For 5” Dia. Round Poles2
UE - Universal Electronic
(120-277V 50/60Hz)
347-480
Distribution
3 - Type III FT - Forward
Throw 5 - Type V
CW - Cool White (5000K) NW - Neutral White (4000K)
Light Source Color Temperature
LEDXLXM3 SS - Super Saver HO - High Output
Drive Current
46-5/8” (1184mm)
Ø4” (102mm)
24-5/8” (625mm)
Post Top with WM Accessory
3-1/3” (84mm)
Ø25-1/2” (648mm)
PT
PT
1.4
2.7
LUMINAIRE EPA CHART - Lexington
MOUNTING STYLE
PT Single
PT D180°
Ø4” (102mm) or Ø5” (127mm)
24-1/2” (622mm)
Ø4” (102mm)
Post Top with BK MPT BO (x2) Mounts to 4” or 5” Dia. D180 Bolt-on Pole
(select 3” reduced drilling pattern)
3-1/3” (84mm)
46-5/8” (1184mm)
Ø25-1/2” (648mm)
18” (457mm)
Post Top Single Slipfits 4” Dia. Tenon (4N) or Pole
42-1/4” (1072mm)
Ø25-1/2”
Ø5” (127mm)
19-3/8” (492mm)
SHIPPING WEIGHTS - Lexington Catalog Number Est. Weight (kg/lbs.)
XLXM3 (PT) 29/64
with BK MPT BO (2)
46-5/8” (1184mm)
Ø4” (102mm)
24-5/8” (625mm)
Post Top with WM Accessory
3-1/3” (84mm)
Ø25-1/2” (648mm)
PT
PT
1.4
2.7
LUMINAIRE EPA CHART - Lexington
MOUNTING STYLE
PT Single
PT D180°
Ø4” (102mm) or Ø5” (127mm)
24-1/2” (622mm)
Ø4” (102mm)
Post Top with BK MPT BO (x2) Mounts to 4” or 5” Dia. D180 Bolt-on Pole
(select 3” reduced drilling pattern)
3-1/3” (84mm)
46-5/8” (1184mm)
Ø25-1/2” (648mm)
18” (457mm)
Post Top Single Slipfits 4” Dia. Tenon (4N) or Pole
42-1/4” (1072mm)
Ø25-1/2”
Ø5” (127mm)
19-3/8” (492mm)
SHIPPING WEIGHTS - Lexington Catalog Number Est. Weight (kg/lbs.)
XLXM3 (PT) 29/64
with BK MPT BO (2)
DIMENSIONS BUG LISTING
XLXM3 PT - TYPE 3
HO CW 8669 108 80 B1-U2-G2
NW 8251 108 76 B1-U2-G1
SS CW 6184 70 88 B1-U1-G1
NW 5930 70 85 B1-U1-G1
HO CW 7510 108 70 B3-U1-G1
NW 6894 108 64 B3-U1-G1
SS CW 5243 70 75 B2-U1-G1
NW 5146 70 74 B2-U1-G1
HO CW 8271 107 77 B1-U2-G2
NW 7560 108 70 B1-U2-G2
SS CW 5572 70 80 B1-U2-G2
NW 5354 70 76 B1-U2-G2
XLXM3 PT - TYPE 5
XLXM3 PT - TYPE FT
Drive Current Color Temp.* Lumens Watts LER BUG Rating
Drive Current Color Temp.* Lumens Watts LER BUG Rating
Drive Current Color Temp.* Lumens Watts LER BUG Rating
* Color Temperature: NW-4000K, CW-5000K rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Rectangle
Owner
PRODUCT DATA
POWDERCOAT CHART
© 2017 Forms+Surfaces® | For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com page 1 of 3 | Rev. 08-27-17
All Forms+Surfaces powdercoat colors have been formulated to be ultra-durable for improved long-term wear and resistance to weathering. Our powdercoat colors are also anti-graffiti, allowing marks from paint, permanent markers, and dirt to be easily removed. All standard and premium powdercoat finishes are no-VOC.
STANDARD TEXTURES
PREMIUM TEXTURES
ALUMINUM TEXTURE ARGENTO TEXTURE BLACK TEXTURE BLUE TEXTURE
CREAM TEXTURE DARK BRONZE METALLIC TEXTURE EVERGREEN TEXTUREDARK GREY METALLIC TEXTURE
INK BLUE TEXTURE SILVER TEXTURE WHITE TEXTURESLATE TEXTURE
AZURE TEXTURE LIME TEXTURE LIGHT CORTEN TEXTUREDARK CORTEN TEXTURE
Owner
© 2017 Forms+Surfaces® | For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com page 2 of 3 | Rev. 08-27-17
STANDARD GLOSS COLORS
NOTE: Due to the inherent nature of metal castings, gloss powdercoats are not offered for cast components.
PRETREATMENT
For improved performance, all aluminum castings go through an environmentally friendly pretreatment process. This pretreatment increases the adhesion of the powdercoat finish and creates a barrier that is highly resistant to environmental corrosion without the use of hazardous ingredients.
FORMS+SURFACES POWDERCOAT FINISHES
Our powdercoat finishes have been specially formulated with dirt-repelling properties and for significantly prolonged gloss retention, which decreases the frequency of cleaning and maintenance. For long-term performance, our powdercoat finishes have high resistance to environmental factors such as UV rays and humidity, industrial pollution, and other atmospheric components.
WEATHER TESTING
Accelerated Weathering
TEST STANDARD TEST PERIOD RESULT
Gloss Retention DIN EN ISO 16474-2 1000H >90%
Condensation Test DIN EN ISO 6270 CH 1000H no infiltration, no bubbles
Salt Spray DIN EN ISO 9227 AASS 1000H no infiltration, no bubbles
Mortar resistance DIN EN ISO 12206-1 (section 5.9) 24h easily removable without residues
NOTE: Blue Texture, Azure Texture and Lime Texture powdercoat finishes have a gloss retention of >50%.
Florida Weathering
TEST LOCATION TEST PERIOD RESULT
Gloss Retention Florida, 5˚ south 3 years >50%
BLACK GLOSS BRIGHT SILVER GLOSS SLATE GLOSS
Owner
© 2017 Forms+Surfaces® | For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com page 3 of 3 | Rev. 08-27-17
POWDERCOAT MAINTENANCE
TYPE CLEANING METHOD FREQUENCY
general maintenance water and sponge once a year or as needed grease alcohol or surfactant; allow time to break down residue before removing as needed lime stains diluted solution of vinegar essence (9.6%) dissolved 1:1 with water as needed mortar residue/cement spray diluted solution of vinegar essence (9.6%) dissolved 1:1 with water as needed silicone stains/adhesive residue silicone remover as needed
NOTE: The following powdercoat colors should be cleaned with water and a sponge only, once a year or as needed: Aluminum Texture, Argento Texture, Dark Bronze Metallic Texture, Dark Grey Metallic Texture, Silver Texture and Bright Silver Gloss.
Do not use: Acids, lyes, strongly alkaline cleaners, abrasive cleaners, abrasive aids or cleaners that contain solvents, thinners, acetone or chlorinated hydrocarbons.
LEARN MORE
Our Resource Management team is dedicated to staying on top of environmental issues around the world. Wherever you are, you can rely on us to help you navigate any challenges a project may pose.
For product-specific environmental data, visit forms-surfaces.com and click on the Environmental Data tab on any product page. To learn more about our company's environmental commitment and programs, visit the Environmental Sustainability section of our website. If you would like additional information on our Environmental Management System or our company environmental initiatives and policies, please feel free to contact our Sustainability Team at green@forms-surfaces.com.
NOTE: Because different computers will render colors and textures differently, actual colors and finishes may vary slightly from those shown here.
https://www.forms-surfaces.com https://www.forms-surfaces.com/environmental-sustainability Owner page 1 of 1 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
LIGHT COLUMN BOLLARD
TECH BRIEFPRODUCT DATA
Owner page 1 of 7 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
Sleek in stainless steel, the Light Column Bollard integrates into a wide range of settings and offers numerous design possibilities. Bollard columns are available in 5" or 6" diameters. Illumination options include LED or linear fluorescent lamps and multiple ways to direct light: no shield for symmetrical lighting, or 180° and 360° shields in standard or custom designs. Non-illuminated and security core variations, and matching Light Column Pathway Bollards and Light Column Pedestrian Lighting make it easy to create a cohesive look across functionalities.
MATERIAL & CONSTRUCTION DETAILS
CONFIGURATIONS MATERIALS & FINISHES FLUORESCENT LAMPS & BALLASTS
• Light Column Bollards are available in two sizes. Series 500 columns use 5" (127 mm) diameter tubular stainless steel; Series 600 columns use 6" (152 mm) diameter tubular stainless steel.
• To complement the illuminated bollard, a non-illuminated version is also available in both Series 500 and Series 600.
• Bollards can be specified with a removable base.
• Weather resistant GFCI outlet for maintenance access is available for Series 600, illuminated, non-security bollards. See drawings on our website for details.
• Door for optional GFCI outlet is accessed using a flathead screwdriver.
• Illuminated bollards have a tubular stainless steel column, white-frosted acrylic lens, and a stainless steel head cap.
• Non-illuminated bollards are tubular stain-less steel with welded stainless steel cap.
• Standard stainless steel finish is Satin.
• For optional powdercoat colors see the Forms+Surfaces Powdercoat Chart. Custom RAL colors are available for an upcharge.
• Linear fluorescent lamps are available in two options.
See lamp information on page 5.
• Ballast is an electronic, thermally protected, 120/277V combination for two F14T5 lamps, -18°C starting temperature, <10% THD, Class A sound rating. Please call for HO ballast specifications.
WEIGHT SHIELD OPTIONS LED LAMPS & DRIVERS
• Series 500, illuminated: 30 lbs (14 kg); non-illuminated: 32-33 lbs (15 kg)
• Series 600, illuminated: 34 lbs (15 kg); non-illuminated: 34-39 lbs (15-18 kg)
• Series 600, security core, illuminated: 170 lbs (77 kg); non-illuminated: 177 lbs (80 kg)
• Four standard shield designs are available for an upcharge. Refer to pages 4 and 5 for details.
• Custom shield designs with either 180° or 360° coverage are also available.
• Shields are offered for Series 500 and Series 600 illuminated bollards.
• Custom LED light engine with Cree® LEDs.
• Features advanced LED technology with 17W, 3000K warm white and 4000K natural white LEDs.
• LED driver input power is 100-277V.
• Driver has 0-10V dimming capabilites.
• LED driver certifications include: IP66 (waterproof) enclosure, and Class 2 rated output (UL8750)
INSTALLATION & MAINTENANCE
INSTALLATION MAINTENANCE
• Standard mounting is surface mount with 1/2"-13x18" galvanized steel J-bolt anchors. 1/2" thick stainless steel base plate is slotted for rotational capability.
• Security bollards use an embedded security core, available with the Series 600, for an upcharge.
• Bollards have the option of a removable base.
• Installation of a surge protector as part of each units wiring is recommended.
• Necessary hardware is included for all mounting options. Templates are available upon request.
• Metal surfaces can be cleaned as needed using a soft cloth or brush with warm water and a mild detergent.
Avoid abrasive cleaners.
STAINLESS STEEL BODY AND SHIELD FINISH
STAINLESS STEEL, SATIN
rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight rfender Highlight
Owner page 2 of 7 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
ILLUMINATED BOLLARDS
NOMINAL DIMENSIONS
SURFACE MOUNT WITH J-BOLTS SURFACE MOUNT WITH REMOVABLE BASE
BASE PLATE MOUNTING DETAILS
7.5" (190 mm) mounting circle
0.63" (16 mm)
5.06" (129 mm) conduit opening
8.0" (203 mm) base plate
6.5" (165 mm) mounting circle
0.63" (16 mm)
6.06" (154 mm) conduit opening
9.0" (229 mm) base plate
SERIES 500, J-BOLT SERIES 600, J-BOLT OR
SECURItY CORE BASE
5" (127 mm) (Series 500) 6" (152 mm) (Series 600) stainless steel compression cap white-frosted acrylic lens linear fluorescent lamps (2x) or lamp holder and wiring channel assembly electronic ballast multi-voltage (120/277V) or LED driver (85/277V) stainless steel column
1/2" (13 mm) thick stainless steel base plate with cover ballast mounting plate or driver mounting plate conduit with 42" (1067 mm) wire whip (by others) poured concrete footer
23.5" (597 mm)
5" (127 mm) custom LED light engine
45" (Standard, non-SEC)
(1146 mm)
1/2"-13 x 5" epoxy anchor
5" (127 mm) (Series 500) 6" (152 mm) (Series 600)
J-bolt anchors (drop-in anchors may also be used) stainless steel compression cap white-frosted acrylic lens linear fluorescent lamps (2x) or lamp holder and wiring channel assembly electronic ballast multi-voltage (120/277V) or LED driver (85/277V) stainless steel column
1/2" (13 mm) thick stainless steel base plate with cover ballast mounting plate or driver mounting plate conduit with 42" (1067 mm) wire whip (by others) poured concrete footer
23.5" (597 mm)
18" (457 mm) min.
for surface mounted
J-bolts custom LED light engine
45" (Standard, non-SEC)
(1146 mm) rfender Rectangle
Owner page 3 of 7 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
ILLUMINATED BOLLARDS - CONTINUED
NOMINAL DIMENSIONS - EMBEDDED SECURITY CORE
OPTIONAL SECURITY CORE
Site security is a major concern in today’s unpredictable world. Public and private buildings, government facilities, campuses and public parks are all susceptible to accidental, as well as deliberate vehicle infringement. Design professionals, city planners, facilities managers and engineers must now be increasingly sensitive to the safety and security requirements of public and private spaces. Security bollards placed at ingress points are an excellent way to guard against vehicle infringement while still allowing pedestrian access.
Until recently, security bollards have frequently taken the form of generic pipes or cylinders that offer little in the way of design or lighting functionality.
Now, an optional enhancement to our Light Column Bollards provides a solution that blends security, performance and style. By adding a pre-engineered security core to our Series 600 design, we're able to respond to the needs of today's public spaces with a beautiful illuminated bollard that meets stringent high-impact crash requirements.
Forms+Surfaces’ security bollards have been tested using a Finite Element Analysis (FEA) by a professional engineering consultant. FEA is a software-based tool commonly used in the automotive industry and used extensively for crash test simulations. Tests were performed using our bollards set in permanent concrete footings spaced 42" apart (to assure a minimum of two bollards being hit) and struck by a vehicle at a 90 degree impact. The impact simulation found the bollards to be successful in stopping a 5,500 lb. vehicle traveling at a minimum test velocity of 40 mph.
In addition to our illuminated security bollards, we can also provide non-illuminated options. Refer to page 6 for details. Please contact us to discuss design and installation considerations for Light Column Bollards with security cores.
Crash scenario with 5,500 lb pickup truck approaching embedded bollard system at 40 mph
Full-scale crash 330ms after impact stainless steel compression cap white-frosted acrylic lens linear fluorescent lamps (2x) or lamp holder and wiring channel assembly electronic ballast multi-voltage (120/277V) or LED driver (85/277V) ballast mounting plate or driver mounting plate poured concrete footer custom LED light engine stainless steel column
1/2" (13 mm) thick stainless steel base plate with cover schedule 160 pipe 5/8" (16 mm) wall thickness welded steel cross supports (2x)
24" (610 mm)
48" (Standard SEC) (1219 mm) or
50" (LED SEC)
(1270 mm)
24" (610 mm)
6" (152 mm) (Series 600)
30" (762 mm)
9" (229 mm) base cover
26.5" (Standard SEC) (673mm) or
28.5" (LED SEC)
(723.9 mm)
Owner page 4 of 7 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
3"
.3"
.378"
.25”
.25”
.125”
.188”
Series 500 Series 600
180 Bollard N/A •
360 Bollard N/A N/A
180 Pedestrian N/A •
360 Pedestrian N/A N/A
Series 500 Series 600
180 Bollard • •
360 Bollard • •
180 Pedestrian • •
360 Pedestrian • •
Series 500 Series 600
180 Bollard • •
360 Bollard • •
180 Pedestrian • •
360 Pedestrian • •
NOTE: A "•" indicates that the shield design is available in the selected series and size combination.
STANDARD SHIELD DESIGNS
KENTE
PERFORATED
SCAPE
Owner page 5 of 7 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
STANDARD SHIELD DESIGNS
LAMP DESCRIPTIONS
LAMP DESCRIPTION BASE COLOR TEMPERATURE LUMINAIRE LUMENS* B.U.G. RATING
500 600
3000K LED 17W custom LED light engine N/A 3,000K 1542 1545 B1-U4-G1
4000K LED 17W custom LED light engine N/A 4,000K 1542 1545 B1-U4-G1
(2) F14T5 14W T5 linear fluorescent Mini bi-pin 4,100K 2220 2195 B1-U4-G2
(2) F24T5/HO 24W T5HO linear fluorescent Mini bi-pin 4,100K 3288 3252 B1-U5-G2
*Luminaire lumens represents the absolute photometry for the luminaire, and indicates the lumens out of the entire fixture.
NOTE: Polar candela and isofootcandle plots can be found on the Light Column Bollard product page on our website.
1.12"
.38"
Series 500 Series 600
180 Bollard • •
360 Bollard • •
180 Pedestrian • •
360 Pedestrian • •
BUBBLES
rfender Highlight
Owner page 6 of 7 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
NON-ILLUMINATED BOLLARDS
NOMINAL DIMENSIONS
SURFACE MOUNT WITH REMOVABLE BASE SURFACE MOUNT WITH J-BOLTS EMBEDDED SECURITY CORE
BASE PLATE MOUNTING DETAILS
6.5" (165 mm) mounting circle
8.0" (203 mm) base plate
5.06" (129 mm) conduit opening
SERIES 500, REMOVABLE BASE
7.5" (190 mm) mounting circle
6.06" (154 mm) conduit opening
9.0" (229 mm) base plate
SERIES 600, REMOVABLE BASE
0.63" (16mm)
9.0" (229 mm) base plate
7.5" (190 mm) mounting circle
SERIES 600, J-BOLT OR
SECURITY CORE BASE
6.06" (154 mm) conduit opening
0.63" (16 mm)
8.0" (203 mm) base plate
5.06" (129 mm) conduit opening
6.5" (165 mm) mounting circle
SERIES 500, J-BOLT
17" (432 mm) min.
for surface mounted
J-bolts
45" (1146 mm)
45" (1146 mm)
5" (127 mm) (Series 500) 6" (152 mm) (Series 600)
5" (127 mm) (Series 500) 6" (152 mm) (Series 600) 6" (152 mm) (Series 600)
45" (1143 mm)
24" (610 mm)
30" (762 mm)
5" (127 mm) poured concrete footer poured concrete footer welded steel cross supports (2x) schedule 160 pipe 5/8" (16 mm) wall thickness
J-bolt anchors (drop-in type anchors may also be used)
9" (229 mm) base cover
1/2" (13 mm) thick stainless steel base plate with cover stainless steel column
24" (610 mm) carbon steel stainless steel columnstainless steel column
1/2" (13 mm) thick stainless steel base plate with cover
1/2" (13 mm) thick stainless steel base plate with cover
1/2"-13 x 5" epoxy anchor poured concrete footer
Owner page 7 of 7 | Rev. 07-21-17
LIGHT COLUMN BOLLARD
© 2017 Forms+Surfaces® | All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.
T 800.451.0410 | www.forms-surfaces.com
CERTIFICATIONS
• UL and C-UL listed for wet locations (linear fluorescent).
• ETL and C-ETL listed for wet locations (LED).
ENVIRONMENTAL CONSIDERATIONS
• Please refer to the Light Column Bollard Environmental Data Sheets for detailed environmental impact information.
• Light Column Bollard has high recycled content and is highly recyclable.
• Powdercoat finishes are no- or low-VOC, depending on color.
• Low maintenance.
MODEL NUMBERS AND DESCRIPTIONS
MODEL DESCRIPTION
LBLCO-504 Light Column Bollard, Series 500, illuminated
LBLCO-604 Light Column Bollard, Series 600, illuminated
LBLCO-504-N Light Column Bollard, Series 500, non-illuminated
LBLCO-604-N Light Column Bollard, Series 600, non-illuminated
PRODUCT OPTIONS
The following options are available for an upcharge
Upgrade to embedded security core (available for Series 600) Add 360° custom shield (customer-supplied artwork)
Upgrade to removable base GFCI outlet (available for Series 600, illuminated, non-security bollards)
Add 180° perforated shield in standard designs Add powdercoat color from Forms+Surfaces Powdercoat Chart
Add 360° perforated shield in standard designs Custom RAL powdercoat color
Add 180° custom shield (customer-supplied artwork) Custom fixture height
LEAD TIME: 6 to 8 weeks. Shorter lead times may be available upon request. Please contact us to discuss your specific timing requirements.
PRICING: Please contact us at 800.451.0410 or sales@forms-surfaces.com. At Forms+Surfaces, we design, manufacture and sell our products directly to you. Our sales team is available to assist you with questions about our products, requests for quotes, and orders. Territory Managers are located worldwide to assist with the front-end specification and quoting process, and our in-house Project Sales Coordinators follow your project through from the time you place an order to shipment.
TO ORDER SPECIFY: Quantity, model, finish, lamp, shield (if applicable), and mounting. Quote/Order Forms are available on our website to lead you through the specification process in a simple checkbox format.
NOTE: Because different computers will render colors and textures differently, actual colors and finishes may vary slightly from those shown here.
rfender Highlight rfender Highlight
Owner
© 2020 Hubbell Outdoor Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.hubbelloutdoor.com
Page 1/4 Rev. 05/18/20
FSLLED-SPEC
FEATURES
• Vented housing design isolates LED module from driver for long life and improved performance
• NEMA distributions: Narrow (3x3), Medium (4x4), Rectangular Medium (5x4) and Wide (6x6)
• Photocontrol available for energy savings
• Universal 120-277V 50/60 Hz
• IP66, listed to UL1598 for use in wet locations
• Visor and vandal lens accessories available
• Seven standard finishes: Dark Bronze, Black, Gray, White, Platinum, Red and Forest Green
FSL PSG
PAG
E
FACTO
R BRO
CH
U
RE
LED
FLO
O
D
LIG
H
TIN
G G
U
ID
E
IN
STALLATIO
N
IN
STRU
CTIO
N
S
FACTOR FSL
DECORATIVE FLOOD
DATE: LOCATION:
TYPE: PROJECT:
CONSTRUCTION
• Corrosion resistant, rugged die-cast aluminum housing with powder coat paint finish
• High impact UV stabilized acrylic outer lens protects LEDs and allows for cleaning and debris removal
• Vented housing isolates LED module from driver, maximizing product life and performance
• Visor and vandal lens available
OPTICS
• 10 high powered LED’s
• MTO Versions: 3000K CCT nominal with 80 CRI, 4000K and 5000K CCT nominal with
70 CRI
• Variety of NEMA distributions: - N (3x3), M (4x4), RM (5x4) and W (6x6) - for wide range of lighting applications;
Stock version Wide (6x6) only
CERTIFICATIONS
• IP66
• Listed to UL1598 for use in wet locations
• DLC Qualified (4000K and 5000K models only); Consult DLC website for more details:
http://www.designlights.org/QPL
WARRANTY
• 5 year limited warranty
• See HLI Standard Warranty for additional information
SPECIFICATIONS
INSTALLATION
• Traditional ½” x 14 NPS threaded adjustable knuckle mounting
• Easy maintenance access to electrical components with removal of 4 screws from back of fixture housing.
ELECTRICAL
• Ambient operating temperature -35°C to
40°C
• Stock Versions: 4000K and 5000K CCT
• 120-277V operation, 50/60Hz
• Driver IP66 and RoHS compliant
• Comes standard with 10KV surge protection device
• 0-10V dimming driver standard, continuous dimming option to have leads pulled out for easy connection
CATALOG #:
Factor FML Factor FLL Factor FXL
RELATED PRODUCTS
KEY DATA
Lumen Range 14,94–22,259
Wattage Range 25
Efficacy Range (LPW) 71–110
Fixture Projected Life (Hours) L70>136K
Weights lbs. (kg) 2.66 (1.2)
IP66
https://www.hubbell.com/hubbelllightingci/en/ https://www.hubbell.com/hubbelloutdoorlighting/en https://www.hubbell.com/hubbelllightingci/en/Products/Lighting-Controls/Commercial-Outdoor-Lighting/Area-Site-Roadway/RAR1-Ratio/p/3233201 https://hubbellcdn.com/catalogpage/hol_fsl_psg.pdf https://hubbellcdn.com/brochure/FACTOR_Floodlight_Brochure.pdf https://hubbellcdn.com/brochure/led_flood_selection_guide_hol0043_lr.pdf https://hubbellcdn.com/installationmanuals/wgh250_400_install.pdf https://hubbellcdn.com/installationmanuals/fsl_fml_instruction_sheet.pdf https://www.hubbell.com/hubbell/en/Products/Lighting-Controls/Commercial-Outdoor-Lighting/Wall-Mount/LNC2-Litepak/p/248677 https://www.hubbell.com/hubbelllightingci/en/warranty https://www.hubbell.com/hubbell/en/Products/Lighting-Controls/Commercial-Outdoor-Lighting/Flood-Lighting/FML-Factor-Floodlight/p/245575 https://www.hubbell.com/hubbell/en/Products/Lighting-Controls/Commercial-Outdoor-Lighting/Flood-Lighting/FLL-Factor-Floodlight/p/245579 https://www.hubbell.com/hubbell/en/Products/Lighting-Controls/Commercial-Outdoor-Lighting/Flood-Lighting/FXL-Factor-Floodlight/p/245577 Owner
Line No. Plan Quantity Unit Description Unit Price Item Total
PARTICIPATING
10 66 SY Removal of Asphalt Pavement, All Depths 20 332 SY Removal of Concrete Sidewalks & Driveways, All Depths 30 509 LF Removal of Curb &/or Curb and Gutter, All Types 40 140 LF Removal of Electric Power Cable, Including Hardware 50 1 EA Removal of Fence Gate, All Types, All Sizes 60 400 LF Removal of Fence, All Types 70 1 EA Removal of Flared End Section, All Sizes 80 1 EA Removal of Inlets, All Sizes 90 280 LF Removal of Pipe, 8" And Above 100 1 EA Removal of Power Pole 110 1 EA Removal of Trees Greater Than 6" 120 1,885 CY Unclassified Excavation, FM, AH 130 679 CY Borrow Excavation, AH, FME, Class B9-6 140 500 CY Excess Excavation, LVM, AH 150 304 CY Structure Excavation 160 1 CY Select Material for Undercuts, Contractor Furnished, FM 170 2 TON Superphosphate 180 3,000 SY Solid Sodding, Bermuda 190 471 SY Ditch Liner 200 2 KGAL Watering 20.00 $40.00 210 4 ACRE Insect Pest Control 30.00 $120.00 220 4 ACRE Mowing 50.00 $200.00 230 308 SY Soil Reinforcing Mat 240 4 ACRE Grassing 250 8 TON Agricultural Limestone 260 8 TON Mulch, Vegetative Mulch 270 4 ACRE Temporary Grassing 280 2,500 LF Temporary Silt Fence 290 2 EA Inlet Siltation Guard 300 500 LF Wattles, 12" 310 50 EA Rockbags 320 60 TON Riprap for Erosion Control 330 1 CY Remove and Reset Riprap
340 4 EA Lighting Assembly, Sign Lighting , LED Linear Flood Light, Including Base
350 475 TON 3/4" and Down Crushed Stone Base
OR
360 475 TON Size 610 Crushed Stone Base
OR
370 475 TON Size 825B Crushed Stone Base 380 337 TON 9.5-mm, MT, Asphalt Pavement 390 4,070 SY Cold Milling of Bituminous Pavement, All Depths 400 205 GAL Asphalt for Tack Coat 410 370 LF Saw Cut, Full Depth 420 29 CY Class "B" Structural Concrete, Minor Structures 430 2,930 LBS Reinforcing Steel
406-A002 407-A001 503-C010 601-B001 602-A001
249-A001 249-B001
907-259-D001
304-F001
304-F002
304-F003 403-A014
224-A001 225-A001 225-B001 225-C001 226-A001 234-A001 234-D001 237-A001 246-B001
203-G002 206-A001 206-B001 213-C001 216-B001 217-A001 219-A001 220-A001 223-A001
202-B125 202-B126 202-B129 202-B165 202-B191 202-B193 202-B248 203-A001
203-EX021
BIDS WILL NOT BE CONSIDERED UNLESS BOTH UNIT PRICES AND ITEM TOTALS ARE ENTERED.
BIDS WILL NOT BE CONSIDERED UNLESS THE BID CERTIFICATE LOCATED AT THE END OF THE BID SHEET IS SIGNED.
Pay Item No.
202-B007 202-B081 202-B089 202-B123
Bid Schedule
Project Number STP-0211-00(015)LPA / 107143 - 701000
County HINDS
Project Description Hinds Community College - Pedestrian and Sidewalk Improvements
I (We) agree to complete the entire project within the specified contract time.
***SPECIAL NOTICE TO BIDDERS***
440 144 LF 18" Type A Alternate Pipe 450 246 LF 18" Reinforced Concrete Pipe, Class III 460 136 LF 24" Reinforced Concrete Pipe, Class III 470 9 EA 18" Reinforced Concrete End Section 480 1 EA 24" Branch Connections, Stub into Box Culvert 490 711 LBS Castings 500 147 LBS Gratings 510 3,283 SY Concrete Sidewalk, With Reinforcement 520 650 SF Detectable Warning Panels 530 82 LF Concrete Curb, Header 540 3,341 LF Combination Concrete Curb and Gutter Type 1 Modified 550 350 SF Brick Pavers 560 1 EA Adjustment of Manhole
570 313 SY Concrete Driveway, With Reinforcement, 6-inch Thickness
580 1 LS Maintenance of Traffic XXXXX 590 2,543 LF Temporary Traffic Stripe, Continuous White, Paint 600 1,727 LF Temporary Traffic Stripe, Continuous Yellow, Paint 610 1,921 LF Temporary Traffic Stripe, Skip White, Paint 620 1,036 LF Temporary Traffic Stripe, Detail, Paint 630 197 SF Temporary Traffic Stripe, Legend, Paint 640 1,470 LF Temporary Traffic Stripe, Legend, Paint
650 530 SF Standard Roadside Construction Signs, Less than 10 Square Feet
660 48 SF Standard Roadside Construction Signs, 10 Square Feet or More
670 156 LF Barricades, Type III, Single Faced 680 104 EA Free Standing Plastic Drums 690 14 EA Warning Lights, Type "B" 700 1 LS Mobilization XXXXX 710 1,921 LF 6" Thermoplastic Traffic Stripe, Skip White 720 2,543 LF 6" Thermoplastic Edge Stripe, Continuous White 730 541 LF 6" Thermoplastic Traffic Stripe, Continuous Yellow 740 1,434 LF 6" Thermoplastic Edge Stripe, Continuous Yellow 750 875 LF Thermoplastic Detail Stripe, White 760 296 LF Thermoplastic Detail Stripe, Yellow 770 602 SF Thermoplastic Legend, White 780 4,562 LF Thermoplastic Legend, White
790 127 SF Standard Roadside Signs, Sheet Aluminum, 0.080" Thickness
800 36 SF Standard Roadside Signs, Sheet Aluminum, 0.125" Thickness
810 486 LF Steel U-Section Posts, 3.0 lb/ft 820 18 EA Remove and Reset Sign, 1 U-post
830 750 LF Electric Cable, Underground in Conduit, THHN, AWG #12, 3 Conductor
840 300 LF Electric Cable, Underground in Conduit, THHN, AWG #6, 3 Conductor
850 2,500 LF Electric Cable, Underground in Conduit, THHN, AWG #8, 3 Conductor
860 1 LS Roadway Construction Stakes XXXXX
870 325 LBS Electric Cable, Service Entrance, Undergroung in Conduit, THHN, 3-#1, 1-#8(G), 2 1/2" C
880 440 LF Remove and Reset, Iron Fence, Post & Gates
890 1 EA Secondary Power Controller, Per Plans , Lighting Controls
900 1 EA Secondary Power Controller, Per Plans , Load Center, NEMA 3R, 12 Circuit
910 1 EA
Secondary Power Controller, Per Plans , New Service Entrance Hardware (Fused Disconnect, Meter Base, Weatherhead, Etc.)
920 3 EA Secondary Power Controller, Per Plans , New Circuit Breakers for Lighting Controls
930 1 LS Removal of, Per Plans Campus Pylon Sign XXXXX
940 1 LF Fence and/or Gate, Per Plans , Match Existing Type
950 1 EA Fence Post, Per Plans , Match Existing Type
960 2,450 SF Stone Pavers, Per Plans
L00088 - 907-202-PP500
L00089 - 907-607-PP503
L00090 - 907-607-PP504
L00091 - 907-611-PP503
907-636-B053
907-636-B056
699-A001
L00023 - 636-B500
L00024 - 202-B500
L00033 - 907-682-PP500
L00033 - 907-682-PP500
L00033 -…
This is the start of the file's text. The full file is on GovTribe.