313332_DWG_TITLE-SHEET.pdf
PDF 237 KB Posted
- Attached to
- Repair Building Landing Zone K16 (MATOC ONLY)
- Solicitation number
- W90VN824R0047
About this file
This document appears to be a set of technical drawings and specifications for the Repair Building Landing Zone K16 contract opportunity. The drawings cover architectural, mechanical, and electrical elements of the project, which includes floor work, interior and exterior wall/ceiling/roof work, miscellaneous work, mechanical work, and electrical work for Building S-302 on the K-16 installation.
The federal contract opportunity is soliciting bids from MATOC contractors in Areas I and II for this repair project. The Solicitation Number is W90VN824R0047 and it is being issued by the Department of the Army Materiel Command, Army Contracting Command. The contract will require the contractor to complete the specified repair and renovation work on the landing zone building.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W90VN824R0047.pdf | ||
| 313332_DWG_ELEC.pdf | ||
| 313332_DWG_ARCH.pdf | ||
| 313332_MECH.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCHEDULE OF DRAWINGS
RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.
T - 1
RING NO. DESCRIPTION OF DRAWINGS
TITLE SHEET
DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS
TITLE SHEET
T-1
A - 1
A - 2
A - 3
ARCHITECTURAL
A - 4
A - 5
A - 6
A - 7
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15333, APO AP 96205-5333
DPW, ENGINEERING SERVICES DIVISON, DESIGN BRANCH
HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN-CASEY
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
FEWR NO. 313332, K-16
BLDG. S-302
K-16KIM, YK
313332
REPAIR LANDING ZONE AREA
BLDG. S-302
REPAIR LANDING ZONE AREA
MECHANICAL
M - 1
M - 2
M - 3
M - 4
M - 5
M - 6
M - 7
M - 8
MECHANICAL MATERIAL INDICATIONS & SYMBOLS
MECHANICAL GENERAL NOTES, NOTES & SCOPE OF WORK
EXIST/REMOVAL HVAC PLAN AND KEY PLAN
EXIST/REMOVAL SPRINKLER HEAD FLOOR PLAN AND KEY PLAN
1ST FLOOR HVAC PLAN AND KEY PLAN
AND KEY PLAN
TOILET PLUMBING FIXTURE PARTIAL PLAN, PLUMBING FIXTURE SCHEDULE-1
KEY PLAN AND NOTES
BAR TABLE PLUMBING FIXTURE PARTIAL PLAN, PLUMBING FIXTURE SCHEDULE-2,
AND KEY PLAN
1ST FLOOR FIRE PROTECTION PIPING PLAN, SPRINKLER Q'TY LIST, NOTE
ELECTRICAL
E - 1
E - 2
E - 3
E - 4
E - 5
E - 6
E - 7
E - 8
E - 9
LEGEND, GENERAL NOTES AND SCOPE OF WORK
NEW LIGHTING PLAN
LIGHTING FIXTURE DETAILS
LIGHTING FIXTURE SCHEDULE
NEW POWER PLAN
1ST FLOOR FA/ TEL/ LAN/ CATV SYSTEMS PLAN
EXIST PANELBOARD "P4" & "P5" LOAD SCHEDULE
ENLARGED POWER PLAN (BAR RM.)
SPEAKER REMOVE AND REINSTALL PLAN
A - 8
A - 9
A - 10
INTERIOR ELEVATIONS
DJ BOOTH PLAN AND DETAILS
DOOR SCHEDULE, ELEVATION AND NOTES
EXISTING 1ST FLOOR PLAN AND GENERAL NOTES
NEW PROPOSED FLOOR PLAN AND SCOPE OF WORK
BAR COUNTER TABLE PLAN, ELEVATION AND DETAILS
WALL SECTIONS AND STORAGE SHELVES DETAILS
DISPLAY CASE, CABINET AND COUNTER TABLE PLANS
ENLARGED FLOOR PLAN, TOILET ACCESSORIES SCHEDULE AND DETAILS
INTERIOR FINISH SCHEDULE AND MATERIAL SCHEDULE