VSS Project Site Visit Questions.docx

DOCX document 13 KB Posted

Attached to
Video Surveillance System Installation Federal contract opportunity
Solicitation number
31010PR240014100
Issued by
Department of Homeland Security US Coast Guard

About this file

This document contains questions and answers from a site visit related to a federal contract opportunity for a Video Surveillance System Installation project at USCG Base Seattle. The key details are:

The contract opportunity is a Request for Quotation (RFQ) solicitation number 31010PR240014100 issued by the U.S. Coast Guard. The contractor will provide labor, materials, and services to install a camera security system, including cameras, monitors, control centers, software, and hardware warranty, as well as provide onsite training for Coast Guard personnel. The site visit questions cover topics such as reuse of existing materials, cable routing, network architecture, and requirements for removal of old equipment. This acquisition is 100% set-aside for small businesses under NAICS code 561621 Security Systems Services. Quotes are due by 4pm PST on 6/12/24 and should be submitted by email to the Contract Specialist. A site visit is highly encouraged but not required, with interested offerors required to arrive no later than 5 minutes prior to the 9am start time on 6/5/24.

View the file

Other files for this federal contract opportunity

Other files attached to Video Surveillance System Installation, newest first.
File Type Posted
BASE Seattle - VSS Enclosure 1 V.2 - 03JUN24.pdf PDF
SF1449-31010PR240014100.pdf PDF
SF1449-31010PR240014100.pdf PDF
Enclosure (1) NFPA Standards and Codes.xlsx XLSX spreadsheet
Wage Determination 15-5535 King County.txt TXT text file
Encl. 2 - NDAA Compliant VSS Whitelist 8-12-2020.pdf PDF
SOW VSS- USCG Base Seattle.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VSS Project Site Visit Questions/Answers

1. Is it possible to re-use material from bldg. 3, SFP’s, cable, fiber etc.

- I don’t have objections for the reuse of SFPs and switches from bldg. 3, however I would object to the reuse of cable runs by pulling and reinstalling elsewhere.

2. Is there cable ran from bldg. 1 straight to Bldg10

- No direct run according to any of the documentation I have seen. If there is one it would run through bldg. 3 anyway and is being demolished. As far as I know, current plans do not include installing an in-ground vault to keep any of those runs.

3. Are cameras on a separate network

- Yes.

4. What is the reason for utilizing both Single Mode and Multi-Mode switches

- Single mode is what has been run recently for our own network, and we happen to have enough to spare for other networks.

5. Will winning bidder be required to remove all old feeds, cable, wires

- No. Old feeds, cables, and wires should be covered in the bldg. 3 demo project. We will also need those runs up until the building is ready to come down.

6. Multi-mode tie-in to what bldg.

- Multimode exists everywhere except the new runs they’ll be patching in. Single mode specifically exists from bldgs. 1 to 7, 7 to 4, and 4 to 10.