About this file
These documents are Record Drawings for an HVAC and Lab Gas Piping project at the TerraPower facility located at 3315 Seaway Blvd in Everett, Washington. The project, completed by MacDonald-Miller Facility Solutions, involves installing new rooftop exhaust fans, single duct terminal units, argon gas piping, and miscellaneous ductwork. The record drawings are dated April 11, 2023, and cover multiple systems including HVAC equipment, ventilation, exhaust fans, air handling units, and lab gas piping infrastructure across the first and second floors of the facility.
The project scope includes installing (1) new rooftop exhaust fan, (2) new single duct terminal units, new argon gas piping, and associated ductwork. The drawings detail specific technical requirements following the 2018 Washington State Mechanical Code, International Mechanical Code, and local building standards. The argon gas system is designed for a 225 psig operating pressure with copper piping and specific valve configurations. The HVAC systems are designed to provide continuous ventilation, with various exhaust fans and air handling units operating on different schedules, including 24/7 continuous operation for certain laboratory spaces and equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Exhibit A - Statement of Work.docx | DOCX document | |
| 2-TerraPower - TI Permit Set.pdf | ||
| 4-TP-LGL-TEMP-0007 TerraPower PO (Long Form) Terms and Conditions Non-USG, Rev 8 (May 31 2022) clean.docx | DOCX document | |
| 5-Final RFP-2025-8352 Ventilation Consultant Proposal Instructions.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECORD DRAWINGS
VICINITY MAP
NO SCALEN
SITE
3315 SEAWAY BLVD
EVERETT, WA 98203
I-5
I-5
HWY 2
POSESSION
SOUND
US NAVAL
STATION
EVERETT
SN
O
HO
M
IS
H
RI
VE
R
HVAC GENERAL NOTES - 2018 WA STATE
1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO
VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2018 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL
FIRE CODE 2018 WSEC, AND LOCAL CODES AND ORDINANCES.
3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2018 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH
ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM.
4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT.
5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2018 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS
- DUCT WRAP, WHERE INDICATED, SHALL BE 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER.
- SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM.
6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON-PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE.
7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2018 IBC.
8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2018 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2018 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE.
9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR
WALL.
10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18".
11. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL
AIR AND WATER DESIGN FLOW RATES.
12. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM.
13. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH 2018 WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS AND SECTION C408.
14. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER
15. SHAFT WALLS CONSTRUCTED TO SUPPORT AIR MOVEMENT FOR RETURN AIR SYSTEMS AND STAIR & ELEVATOR PRESSSURIZATION SYSTEMS SHALL BE CONSTRUCTED TO THE FOLLOWING
STANDARDS:
A. SHAFTS (RATED FOR MAXIMIUM 2" WC) SHALL BE CONSTRUCTED TO WITHSTAND 15 PSF LOADING WITH A DEFLECTION OF L/360 (UNO).
B. SHAFTS SHALL BE SEALED SUBSTANTIALLY AIR-TIGHT USING THE CRITERIA FROM THE 2018 INTERNATIONAL BUILDING CODE:
1. SECTION 715.6 FIRE RESISTANT JOINT SYSTEMS IN SMOKE BARRIERS: LEAKAGE SHALL NOT EXCEED 5 CFM PER LINEAR FOOT OF JOINT AT 0.3" WC.
2. SECTION 909.5 SMOKE BARRIER CONSTRUCTION FOR INTERIOR EXIT STAIRWAYS AND EXIT PASSAGEWAYS: MAXIMUM ALLOWABLE LEAKAGE AREA PER SHAFT SHALL NOT EXCEED
(0.00035 SF/SF)
C. STAIR AND ELEVATOR PRESSURIZATION SHAFTS SHALL BE PRESSURE TESTED DURING COMMISIONING. CONTRACTOR SHALL MAKE MODIFCATIONS TO INSTALLATION UNTIL SHAFT IS IN
COMPLIANCE.
16. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500D): MOTORIZED DAMPERS: 4 CFM/S.F. GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION) PER 2018 WSEC C403.7.8.3.
17. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, 2018 WSEC SECTION C403.7.8.
EXCEPT AS ALLOWED BY WSEC.
18. MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL BE LISTED AND LABELED AS HAVING A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723, EXCEPT AS NOTED IN SECTION 602.2.1 OF THE 2018 IMC.
LEGAL DESCRIPTION
PARCEL NUMBER: 28040300400300
LEGAL DESCRIPTION: SEC 03 TWP 28 RGE 04LOT 1 OF SEAWAY CENTER TWO/INTERMIC BSP REC VOL 1 PGS 181 THRU 183 AF 8910255009 & BEING PTN SE1/4
SCOPE OF WORK
INSTALL (1) NEW ROOFTOP EXHAUST FAN
INSTALL (2) NEW SINGLE DUCT TERMINAL UNITS
INSTALL NEW ARGON GAS PIPING PER PLANS
MISC. DUCTWORK PER PLANS
DRAWING SHEET INDEX - HVAC
NUMBER TITLE
TM0.01 SCHEDULES
TM0.02 SCHEDULES
TM0.01S SITE PLAN
TM2.01A 1ST FLOOR PARTIAL PLAN - HVAC
TM2.02A 2ND FLOOR PARTIAL PLAN - HVAC
TM2.03A ROOF PARTIAL PLAN - HVAC
TF2.01A 1ST FLOOR PARTIAL PLAN - FITTING
TM3.01 ELEVATIONS
TM6.01 DETAILS
CONTACT LIST
TITLE NAME COMPANY PHONE NUMBER EMAIL
PROJECT DESIGN ENGINEER ATTICUS ZBOROWSKI MACDONALD MILLER 206-768-4130 ATTICUS.ZBOROWSKI@MACMILLER.COM PROJECT EXECUTIVE KEVIN ANWAY MACDONALD MILLER 206-768-4102 KEVIN.ANWAY@MACMILLER.COM SPECIAL PROJECTS COORDINATOR RYAN MILLER MACDONALD MILLER 206-519-4378 RYAN.MILLER@MACMILLER.COM SHEETMETAL SUPERINTENDENT NATHAN WAAGEN MACDONALD MILLER 206-768-3942 NATHAN.WAAGEN@MACMILLER.COM CONTROLS SPECIALIST SUPERVISOR ADAM KLETT MACDONALD MILLER 206-768-4174 ADAM.KLETT@MACMILLER.COM ELECTRICAL SUPERINTENDENT DAVE GOFF MACDONALD MILLER 206-510-6481 DAVE.GOFF@MACMILLER.COM PROJECT START UP TIM ANDERSON MACDONALD MILLER 206-768-4168 TIM.ANDERSON@MACMILLER.COM COMMISSIONING FOREMAN BRIAN WHEELER MACDONALD MILLER 206-571-2659 BRIAN.WHEELER@MACMILLER.COM PIPING SUPERINTENDENT RYAN MARTIN MACDONALD MILLER 206-423-5233 RYAN.MARTIN@MACMILLER.COM
GENL. SUPT. JIM WELTON 206-501-9847
GENL. PROJ. MGR. ANDY FORTINO 206-851-9551
EXISTING DEDICATED OUTSIDE AIR SYSTEM UNIT SCHEDULE
SUPPLY DX COOLING GAS HEATING ELECTRICAL DIMENSIONS
UNIT MFGR MODEL LOCATION MAX MIN QTY QTY ESP REFRIGERANT EER/ TOTAL SENSIBLE EAT LAT INPUT OUTPUT EAT LAT SCCR L W H WT
NO. FAN OSA IN IEER CAPACITYCAPACITY DB/WB DB/WB DB DB
CFM CFM (HP) (BHP) WG (MBH) (MBH) (°F) (°F) MBH MBH (°F) (°F) STAGES VOLT/PH MCA MOP (kAIC) (IN) (IN) (IN) LBS NOTES HVU-1-01 VALENT VPR-352-30E-120I-C-5GX ON GRADE 6,750 6,000 2 (15) 2 (12.8) 3 R-410A 11 / 15.9 395.6 339.7 78.2 / 65.4 59.9 / 58.1 1200 960 21 71 10:1 460/3 106.3 110 65 185 96 99.5 7,760 EXISTING, 1-15, 16 HVU-1-02 VALENT VPR-352-30E-120I-C-5GX ON GRADE 17,000 6,400 2 (15) 2 (12.8) 3 R-410A 11 / 15.9 395.6 339.7 78.2 / 65.4 59.9 / 58.1 1200 960 21 71 10:1 460/3 106.3 110 65 185 96 99.5 7,760 EXISTING, 1-15 HVU-1-03 VALENT VPR-352-30E-120I-C-5GX ON GRADE 17,000 6,400 2 (15) 2 (12.8) 3 R-410A 11 / 15.9 395.6 339.7 78.2 / 65.4 59.9 / 58.1 1200 960 21 71 10:1 460/3 106.3 110 65 185 96 99.5 7,760 EXISTING, 1-15
NOTES:
1. POWER WIRING AND DISCONNECT BY ELECTRICAL CONTRACTOR.
2. FACTORY MOUNTED VARIABLE FREQUENCY DRIVE PROVIDED TO DRIVE TWO FAN MOTORS. A COMMON SIGNAL FROM THE BMS SHALL PROVIDE VFD SPEED CONTROL. VFD MODEL: ABB ACS320.
3. HORIZONTAL SUPPLY AND RETURN CONNECTIONS.
4. UNIT MOUNTED ON 4" CONCRETE HOUSEKEEPING PAD.
5. SUPPLY FANS ARE RIGIDLY MOUNTED WITHIN UNIT - NO VIBRATION ISOLATION PROVIDED.
6. HIGH TURN DOWN, MODULATING GAS FURNACE CONTROLLED OFF DISCHARGE AIR TEMPERATURE SENSOR (FACTORY PROVIDED). SEE SEQUENCE OF OPERATIONS.
7. GAS PRESSURE REGULATOR BY MECHANICAL CONTRACTOR.
8. CONTROL THROUGH DDC SYSTEM WITH BACNET COMMUNICATION CAPABILITIES.
9. 4" MERV 14 FILTERS & 2" MERV 8 PRE-FILTERS.
10. LOW LEAKAGE ECONOMIZER MODULATING DAMPERS WITH FACTORY PROVIDED AIR FLOW MEASURING STATION. GREENHECK MODEL AMD-23.
11. DOUBLE WALL CONSTRUCTION WITH 2" FOAMINJECTED INSULATION FOR CASING
12. SEPARATE 120V/1PH POWER FEED FOR GFI CONVENIENCE OUTLET RECEPTACLE. POWER WIRING BY ELECTRICAL CONTRACTOR.
13. MAGNEHELIC GAUGE FOR PRE-FILTER AND FINAL-FILTER.
14. CONTROLS PROVIDED AND INSTALLED BY CONTROLS CONTRACTOR.
15. CONTROLS CONTRACTOR TO INTERLOCK UNIT WITH EXISTING SMOKE DETECTION SYSTEM TO AUTOMATICALLY SHUTDOWN UNIT.
16. CONNECT SUPPLY AND RETURN AIR DUCTWORK TO UNIT AS SHOWN ON PLANS. PROVIDE NEW OSA HOOD TO UNIT. MECHANICAL CONTRACTOR SHALL PROVIDE COMMISSION/START UP OF UNIT.
EXHAUST FAN SCHEDULE
UNIT FAN WT
NO. AREA SERVED MFG & MODEL NO. TYPE CFM ESP RPM FLA FEG BHP HP VOLT/PH BDD LBS NOTES
EF-R-18 ANALYTIC LAB 123 GREENHECK G-143HP-VG CENT. DB 1,080 2.0 2,122 11.3 3/4 115/1 - 95 EXISTING, 1, 7, 8 EF-R-19 NA/CHEM LAB 125 COOK 135TCNHBLE10M TUBULAR CENT 2,400 2.0 2,817 3 460/3 - 1093 EXISTING, 1, 6 EF-R-20 NA/CHEM LAB 125 & TREAT COOK 135TCNHBLE09M TUBULAR CENT 1,500 2.0 2,568 3 460/3 - 1049 EXISTING, 1, 6 EF-R-21 RADIOCHEM LAB 124 GREENHECK CSW-12-BI-21-10-II-50 UTILITY 2,400 6.4 3,809 7.6 5 460/3 - 243 EXISTING, 1, 2, 3, 4, 5 EF-R-25 TAT LABS 127-129 COOK 150 CPS-A CL2 CENT. UB 4,100 7 3,340 10 460/3 - 2210 EXISTING EF-R-26 TAT LABS 127-129 COOK 150 CPS-A CL2 CENT. UB 4,100 7 3,340 10 460/3 - 2210 EXISTING EF-R-27 TAT LABS 127-129 COOK 150 CPS-A CL2 CENT. UB 4,100 7 3,340 10 460/3 - 2210 EXISTING EF-R-28 130-SN-1 COOK 100 TCNHBLE-05 TUBULAR CENT 500 1 2,556 1/2 460/3 - 704 EXISTING EF-R-29 MCFR CONTROLLED GREENHECK USF-409-10-BI-II-30 CENT. UB 1050 6 3600 - 3 460/3 - 199 EXISTING, 1, 3, 9, 10 EF-R-30 FUME HOOD FH-104 GREENHECK USF-10 UTILITY 1,290 1.4 2186 - 3/4 460/3 - 127 EXISTING,1, 3, 9, 11, 12 EF-R-31 UPS ROOM 102 COOK ACRU-B CENT. UB 750 0.5 1,368 5.8 1/4 115/1 - 90 EXISTING, 1, 13, 14 EF-R-32 IES MODULES COOK ACRU-B CENT. UB 750 0.5 1,368 5.8 1/4 115/1 - 90 EXISTING, 1, 13 EF-R-33 FUME HOOD FH-129 COOK 135 CPA UTILITY 1,300 1.5 1900 2.1 1 460/3 - 146 EXISTING, 5, 15-18 EF-R-34 DU LAB CDD 400ECO UTILITY 4,200 2.5 1,725 - - 2.9 5 460/3 - 88 NEW, 1-3, 19-20
NOTES:
1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR.
2. CONTROL CONTRACTOR TO INTERLOCK FAN TO BUILDING EMS DDC CONTROLS.
3. HAZARDOUS EXHAUST FAN SYSTEM, THUS ELIMINATING MOTORIZED DAMPER PER 2015 WSEC C403.2.4.4 EXCEPTION.
4. FACTORY OPTIONS:
- UTILITY SET WITH UP BLAST CONFIGURATION AND VELOCITY STACK
- BOTTOM DRAIN PLUG
- WEATHER COVER
- BACKWARD INCLINED WHEEL
- EXHAUST SUPPORTS W/ 1" DEFLECTION SEISMIC VIBRATION ISOLATORS
- SPARK B CONSTRUCTION
- COATED W/ HI-PRO POLYESTER, CONCRETE GRAY, FAN & DAMPERS
- SHAFT SEAL W/ RUB RING
- PREMIUM EFFICIENCY MOTOR WITH BELT DRIVE.
5. CONTINUOUS OPERATION WITH CONNECTION TO EMERGENCY POWER SYSTEM.
6. EXISTING WALL SWITCH IN ROOM TO TURN FAN ON/OFF.
7. FACTORY OPTIONS:
- 18" GREENHECK ROOF CURB
- MOTORIZED DAMPER 115 VAC (LOW LEAKAGE W/ END SWITCH)
- VARI-GREEN EC MOTOR WITH REMOTE DIAL WALL MOUNTED POTENTIOMETER
- SWITCH, NEMA 1, TOGGLE, JUNCTION BOX MOUNTED & WIRED
- BIRDSCREEN
8. ELECTRICAL CONTRACTOR TO INTERLOCK MOTORIZED DAMPER TO EXHAUST FAN. DAMPER TO OPEN WHEN FAN OPERATES.
ELECTRICAL CONTRACTOR TO ALSO INTERLOCK VARI-GREEN EC MOTOR REMOT DIAL WALL MOUNTED POTENTIOMETER FURNISHED BY M.C. AND INSTALLED BY EC.
9. FACTORY OPTIONS:
- UP BLAST CONFIGURATION
- BOTTOM DRAIN PLUG
- WEATHER COVER
- BACKWARD INCLINED WHEEL
- EXHAUST SUPPORTS W/ 1" DEFLECTION SEISMIC VIBRATION ISOLATORS
- SPARK B CONSTRUCTION
- COATED W/ HI-PRO POLYESTER, CONCRETE GRAY, FAN & DAMPERS
- SHAFT SEAL W/ RUB RING
- VARI-GREEN EC MOTOR PREMIUM EFFICIENCY.
10. ELECTRICAL CONTRACTOR TO PROVIDE WALL SWITCH IN ROOM TO TURN FAN ON/OFF. LOCATION OF SWITCH TO BE OWNER APPROVED.
11. VFD WITH BY-PASS IN NEMA 3 ENCLOSURE PROVIDED BY M.C. VFD CONNECTION AND LOCAL FAN SWITCHING BY E.C.
12. SERVES OWNER PROVIDED HOOD, FH-104. AIR BALANCE HOOD WITH SASH OPENING AT 28 INCHES OPEN TO PROVIDE APPROXIMATELY 12 S.F. OPEN AREA.
13. FACTORY OPTIONS:
- UP BLAST CONFIGURATION
- AMCA SPARK A CONSTRUCTION
- RCA 13.5 INCH ROOF CURB WITH DAMPER TRAY
- ALUMINUM CONSTRUCTION
- BIRDSCREEN
- VIBRATION ISOLATORS
14. HYDROGEN MONITOR AND LOCAL ALARM SYSTEM MODEL SBS-H2 (PROVIDED BY OTHERS AND INSTALLED BY MM).
15. WITH PREMIUM EFFICIENCY MOTOR AND NON-BY PASS VARIABLE FREQUENCY DRIVE, VFD-1 (SEE VFD SCHEDULE).
16. WITH ALUM ACC DOOR-BOLT, ALUM. DRAIN, OSHA BG/WEATER COVER- STL. AND ROTARY BELT TENSIONER.
17. FAN TO OPERATE 24/7 - NO BMS CONNECTION REQUIRED.
18. POWER WIRING BY E.C. NOTE: POWER DISCONNECT PROVIDED IN VFD-1.
19. FACTORY OPTIONS:
- UTILITY SET WITH UP BLAST CONFIGURATION AND MC TO FABRICATE ALUMINUM VELOCITY STACK WITH HANDLES FOR REMOVAL
- POLYPROPYLENE FAN WITH TEFC MOTOR AND PVC MOTOR COVER
- NON FERROUS FAN CONSTRUCTION
- MC TO FABRICATE SLED FOR MOUNTING ON SLEEPERS PROVIDED BY GC
- BOTTOM DRAIN TROUGH
- FACTORY PROVIDED NEMA-4 VFD CONTROLLER WITH DISCONNECT SWITCH
- BACKWARD INCLINED WHEEL
- FACTORY PRIVIDED SPRING ISOLATORS
20. VFD PROVIDED BY FACTORY. VFD CONNECTION AND LOCAL FAN SWITCHING BY E.C.
HOOD SCHEDULE
UNIT AREA EXHAUST FAN EXH SUPPLY SUPPLY EXH
NO. SERVED INTERLOCK MFG & MODEL NO. DIMENSIONS CFM CFM ESP COLLAR SIZE COLLAR SIZE NOTES
FH-101 - EF-R-21 LABCONCO PROTECTOR 96/36/102 1200 - 0.5 - 2-12" EXISTING, 1, 2, 3 FH-102 - EF-R-21 LABCONCO PROTECTOR 96/36/102 1200 - 0.5 - 2-12" EXISTING, 1, 2, 3
FH-103 - EF-R-19 LABCONCO PROTECTOR 96/36/102 1200 - 0.5 - 14" EXISTING, 1, 2, 3
FH-104 - EF-R-30 KEWAUNEE SUPREME AIR 72/54 1290 - 0.4 - 12" EXISTING, 1, 4, 5
FH-105 - EF-R-20 LABCONCO PROTECTOR 96/36/102 1200 - 0.5 - 14" EXISTING, 1, 2, 3
FH-129 - EF-R-33 LABCONCO PROTECTOR 72/-/- 1300 - - - - EXISTING, 2, 4-6
FH-130 DU LAB EF-R-34 - 48/-/- 800 - - - - NEW, 1-2
FH-131 DU LAB EF-R-34 - 48/-/- 800 - - - - NEW, 1-2
FH-132 DU LAB EF-R-34 - 48/-/- 800 - - - - NEW, 1-2
FURNACE EXHAUST DU LAB EF-R-34 - - 1200 - - - - -
NOTES:
1. OWNER PROVIDED AND INSTALLED.
2. FIELD TO VERIFY MAKE AND MODEL.
3. BALANCER SHALL SET SASH HEIGHT TO 18" AND TEST HOOD VELOCITY AT 100 FPM.
4. BALANCER SHALL SET SASH HEIGHT TO 28" AND TEST HOOD VELOCITY AT 100 FPM.
5. OWNER PROVIDED AND RELOCATED BY OTHERS. VERIFY EXACT LOCATION. MMFS TO ASSIST IN REASSEMBLY
6. E.C. TO PROVIDE POWER WIRING, DISCONNECT AND LOCAL FAN CONTROL.
SERVER ROOM LOAD MATRIX - UPS BASED
GENERAL INFORMATION
ROOM # AREA (SF) LIGHTS (W/SF) PEOPLE (#) NOTES
WAR ROOM 910 0.8 8
CUSTOMER INFORMATION
UNIT MFG & MODEL NO. NOM. KVA MAX LOADING POWER FACTOR MAX HEAT
LOAD (BTU)
MAX HEAT
LOAD (KW) SENS. TONS
GLVBX #1 UPS - 2.4 70% 100% 5734 1.7 0.5 2
GLVBX #2 UPS - 2.4 70% 100% 5734 1.7 0.5 2
GLVBX #2 UPS - 2.4 70% 100% 5734 1.7 0.5 2
TOTAL: 17202 5.0 1.4
LOAD EVALUATION
LOADS (BTU) (KW) SENS. TONS
TOTAL MAXIMUM LOAD: 17202 5.0 1.4
NOTES:
1. NO REDUNDANT CAC UNITS HAVE BEEN PROVIDED.
2. LOAD VALUES RECEIVED FROM TERRA POWER 9-29-22
HUMIDITY CONTROL NO
N+1 REDUNDANCY NO
AUTO SWITCH-OVER NO
EXTERNAL ALARMING/MONITORINGNO
FM 200 SYSTEM NO
HYDROGEN GAS MONITORINGNO
APPROVED BY: _____________________________________________________________ DATE: ________________
DUCTWORK SCHEDULE
WORKING SMACNA SMACNA
SERVICE / PRESSURE PRESSURE SEAL
USAGE LOCATION MATERIAL (IN. WC) CLASS (IN. WC) CLASS NOTES
OUTDOOR AIR INTAKE BETWEEN AMBIENT AND AHU GALV. STEEL 0.5 1 B 1
MEDIUM PRESSURE SUPPLY AIR BETWEEN AHU AND TERMINAL UNITS GALV. STEEL 2.5 4 A 1
LOW PRESSURE SUPPLY AIR FROM TERMINAL UNITS TO GRD'S GALV. STEEL 1 1 B 1
FLEXIBLE DUCT CONN TO GRD'S PREINSUL. FLEX 0.5 RATED +6", -1" NA 2, 3
RETURN AIR FROM GRD'S TO AHU GALV. STEEL 1 1 B 1
GENERAL EXHAUST FROM GRD TO FAN AND AMBIENT GALV. STEEL 1 1 B 1
HAZARDOUS EXHAUST FROM FUME HOODS TO EXHAUST FAN 20-24 GA GALV. STEEL 1 1 B 1
NOTES:
1. SHEET METAL GAUGES AND FITTINGS PER SMACNA AND MACDONALD-MILLER DUCT CONSTRUCTION STANDARDS.
2. THERMAFLEX "GKM" OR EQUAL, WITH 12 FOOT MAXIMUM LENGTH.
3. INSTALL PER MFG. GUIDELINES AND INSTRUCTIONS.
AIR TERMINAL SCHEDULE
TAG MANUFACTURER & MODEL
NUMBER SIZE TYPE NOTES
SHOEMAKER HL AS NOTED ARCH T-BAR HIGH VOLUME PLAQUE DIFFUSER MATCH TO EXISTING
SHOEMAKER 903 AS NOTED DOUBLE DEFLECTION SIDEWALL DIFFUSER MATCH TO EXISTING
ROOM PRESSURIZATION & AIR FLOW MATRIX
RO
OM
SP
AC
E
US
E
FL
OO
R
AR
EA
HE
IG
HT
RO
OM
V
OL
UM
E
CO
DE
R
EQ
UI
RE
D
AC
/H R
(T
OT
AL
CO
DE
R
EQ
UI
RE
D
SU
PP
LY
C
FM
(T
OT
AL
CO
DE
R
EQ
UI
RE
D
OS
A
AC
/H R
CO
DE
R
EQ
UI
RE
D
OS
A
CF
M
CO
DE
P
RE
SS
UR
E
RE
LA
TI
ON
SH
IP
DE
SI
GN
S
UP
PL
Y
CF
M (T
OT
AL
DE
SI
GN
A
C/
HR
(T
OT
AL
DE
SI
GN
M
IN
O
SA
CF
M
DE
SI
GN
O
SA
A
C/
HR
EX
HA
US
T
AI
R
CF
M
DE
SI
GN
P
RE
SS
UR
E
RE
LA
TI
ON
SH
IP
C
FM
DU LAB LABORATORY 910 16 14560 0 0 0 90 N 3750 15 3750 15 4200 -450
ABBREVIATIONS:
N = NEGATIVE
P = POSITIVE
NA = NOT APPLICABLE
E = EQUAL OR NEUTRAL
SIZE
CFMA
SIZE
CFMB
SINGLE DUCT VAV BOX SCHEDULE
UNIT MFG & INLET VALVE CFM ELECTRIC HEAT
CONTROLNO. AREA SERVED MODEL NO. SIZE MAX MIN KW STAGES NOTES
VAV-1-01 ANALYTIC LAB 123 PRICE DESV 10 980 590 - - 24V EXISTING 1-3
VAV-1-02 DU LAB PRICE SDV 16 3750 3750 24 SCR 24V NEW, 1, 10, 11
VAV-1-07 WAREHOUSE NORTH PRICE SDV5 - - - - - - FUTURE
VAV-1-06 WAREHOUSE SOUTHEAST PRICE SDV 14 3000 2250 - - 24V NEW, 1, 11
VAV-1-08 WAREHOUSE NORTH PRICE SDV5 - - - - - - FUTURE
VAV-1-09 WAREHOUSE NORTH EXTERIOR PRICE SDV5 24x16 5000 3000 - - 24V EXISTING 1-3
VAV-1-10 MICROSCOPY LAB 124 PRICE SDV5 4 150 150 - - 24V EXISTING 1-3
SVAV-1-01 TAT GENERAL LAB 127 ANTEC (PRICE) VDX 214 30x15 3615 2000 - - FACTORY EXISTING, 1-3 SVAV-1-02 TAT GENERAL LAB 127 ANTEC (PRICE) VDX 114 14 1785 975 - - FACTORY EXISTING, 1-3 SVAV-1-03 TAT COMP LAB 129 ANTEC (PRICE) VDX 114 14 1700 925 - - FACTORY EXISTING, 1-3 SVAV-1-04 TAT COMP LAB 128 ANTEC (PRICE) VDX 114 14 1700 925 - - FACTORY EXISTING, 1-3 SVAV-1-05 RADIOCHEM LAB 124 ANTEC (PRICE) VDX 214 30x15 2100 2100 - - FACTORY EXISTING, 1-3 SVAV-1-06 NA/CHEM LAB 125 PRICE SDV5 24x16 3400 2040 - - FACTORY EXISTING 1-3
SVAV-1-07 LOBBY ANTEC (PRICE) VFX 108 8 125 125 - - FACTORY EXISITNG, 1-4, 7
SVAV-1-8 R&D 2 ANTEC (PRICE) VFX 108 8 251 251 - - FACTORY EXISITNG, 1-3, 5, 7
SVAV-1-09 TECH ANTEC (PRICE) VFX 108 8 307 307 - - FACTORY EXISITNG, 1-4, 7
SVAV-1-10 R&D 1 ANTEC (PRICE) VFX 108 8 436 436 - - FACTORY EXISITNG, 1-4, 7
EVAV-1-01 TAT GENERAL LAB 127 ANTEC (PRICE) VV 214 30X15 3615 2000 - - FACTORY EXISTING 6, 9 EVAV-1-02 TAT GENERAL LAB 127 ANTEC (PRICE) VV 114 14 1785 975 - - FACTORY EXISTING 6, 9 EVAV-1-03 TAT GENERAL LAB 127 ANTEC (PRICE) VV 114 14 1700 925 - - FACTORY EXISTING 6, 9 EVAV-1-04 TAT GENERAL LAB 127 ANTEC (PRICE) VV 114 14 1700 925 - - FACTORY EXISTING 6, 9 EVAV-1-05 TAT CGMP LAB 128 ANTEC (PRICE) VV 214 30X15 4250 1865 - - FACTORY EXISTING 6, 9 EVAV-1-06 TAT CGMP LAB 129 ANTEC (PRICE) VV 114 14 1950 840 - - FACTORY EXISTING 6, 9
EVAV-1-07 LOBBY ANTEC (PRICE) VV 108 8 178 178 - - FACTORY EXISITNG, 1-4, 6,7
EVAV-1-8 R&D 2 ANTEC (PRICE) VV 108 8 280 280 - - FACTORY EXISITNG, 1-4, 6,7
EVAV-1-09 TECH ANTEC (PRICE) VV 108 8 410 410 - - FACTORY EXISITNG, 1-4, 6,7
EVAV-1-10 R&D 1 ANTEC (PRICE) VV 108 8 210 116 - - FACTORY EXISITNG, 1-4, 6,7
EVAV-1-11 HC R & D 2 ANTEC (PRICE) VV 108 8 80 80 - - FACTORY EXISTING, 1-4, 6,7,8 EVAV-1-12 GB R & D 2 ANTEC (PRICE) VV 108 8 35 35 - - FACTORY EXISTING, 1-4, 6,7,8 EVAV-1-13 GB R & D 1 ANTEC (PRICE) VV 108 8 35 35 - - FACTORY EXISTING, 1-4, 6,7,8 EVAV-1-14 HC R & D 1 ANTEC (PRICE) VV 108 8 490 395 - - FACTORY EXISTING, 1-4, 6,7,8 EVAV-1-15 GB R & D 1 ANTEC (PRICE) VV 108 8 35 35 - - FACTORY EXISTING, 1-4, 6,7,8
EVAV-1-16 TECH ANTEC (PRICE) VV 108 8 405 405 - - FACTORY EXISITNG, 1-4, 6,7
NOTES:
1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR.
2. FIBRE FREE INSULATION.
3. CONTROL WIRING BY CONTROLS CONTRACTOR. PROVIDE WITH PACE CONTROLLER BACNET MS/TP INTERFACE.
4. HORIZONTAL CONFIGURATION
5. VERTICAL CONFIGURATION
6. PHENOLIC COATING (HERESITE CLASS 2)
7. VALVE PRESSURE SWITCH
8. VALVE TO OPERATE ON COMECER SIGNAL FOR AIRFLOW ADJUSTMENT TO COMPENSATE FOR HOT CELL VARIOUS OPERATING SCENARIOS.
9. ALL FUME HOOD VALVES TO INCLUDE FUME HOOD CONTROLLER, FUME HOOD MONITOR WITH DIGITAL DISPLAY, SASH POSITION SENSOR AND SIDEWALL SENSOR.
10. VAV DAMPER TO BE SET TO FAIL OPEN
11. CC TO PROVIDE DDC INTERFACE
OWNER PROVIDED GLOVE BOX
UNIT AREA EXHAUST FAN MFG & EXH EXH NOTES
NO. SERVED INTERLOCK MODEL NO. DIMENSIONS CFM COLLAR SIZE
GB-1 DU LAB EF-R-34 - - 200 - NEW, 1-2
GB-2 DU LAB EF-R-34 - - 200 - NEW, 1-2
GB-3 DU LAB EF-R-34 - - 200 - NEW, 1-2
NOTES:
1. OWNER PROVIDED AND INSTALLED
2. FIELD TO VERIFY MAKE AND MODEL
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
0_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:2
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
SC
H
ED
U
LE
S
TM0.01
H
VA
C
X X X X X X
X X X
AHU-001
CO
NO2
S
14x12 SA
14x12 SA-SL
12ø SA
12ø SA-W
14x12ø SA
14x12ø SA-W
14x12 SA
14x12 SA-W
XXXXXXXXX xxxxxxxx
14x12 SA
14x12 SA
14x12 SA-Q
14x12 SA-C
14x12 SA-DB
24ø
24x24
14ø 14ø
T
MECHANICAL GENERAL ABBREVIATIONS
ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME
AC AIR CONDITIONING UNIT FCU FAN COIL UNIT NOM NOMINAL
AFF ABOVE FINISHED FLOOR FD FIRE DAMPER NTS NOT TO SCALE
AHU AIR HANDLING UNIT FLA FULL LOAD AMPS OBD OPPOSED BLADE DAMPER
AL ALUMINUM FOB FLAT ON BOTTOM OD OUTSIDE DIMENSION
BAS BUILDING AUTOMATION SYSTEM FOT FLAT ON TOP POC POINT OF CONNECTION
BDD BACK DRAFT DAMPER FSD FIRE SMOKE DAMPER PRV PRESSURE REDUCING VALVE
BI BLACK IRON GALV GALVANIZED PVC POLYVINYL CHLORIDE
BOD BOTTOM OF DUCT GC GENERAL CONTRACTOR REQ’D REQUIRED
BOTT BOTTOM GENX GENERATOR EXHAUST RPBA REDUCED PRESSURE BACKFLOW ASSY
BTU BRITISH THERMAL UNITS GLVNL GALVANNEAL RTU ROOFTOP UNIT
BTUH BRITISH THERMAL UNITS PER HOUR GPM GALLONS PER MINUTE SA SUPPLY AIR
CAT1 CATEGORY ONE VENT GREASE GREASE DUCT SD SMOKE DAMPER
CAT4 CATEGORY FOUR VENT GWB GYPSUM WALL BOARD SL SOUND LINED
CFM CUBIC FEET PER MINUTE HP HORSE POWER, HEAT PUMP SM SHEET METAL
CPVC CPVC MATERIAL HVAC HEATING, VENTILATION AND AIR COND. SP STATIC PRESSURE
DB DUCTBOARD HX HEAT EXCHANGER SS STAINLESS STEEL
DDC DIRECT DIGITAL CONTROLS ID INSIDE DIMENSION SUSP SUSPENDED
DEMO DEMOLISH LAT LEAVING AIR TEMPERATURE T THERMOSTAT
DIFF DIFFUSER LBS POUNDS TOD TOP OF DUCT
DMPR DAMPER LWT LEAVING WATER TEMPERATURE TV TURNING VANES
DN DOWN MAT MIXED AIR TEMPERATURE TYP TYPICAL
E EXISTING MBH ONE THOUSAND BTUH UNO UNLESS NOTED OTHERWISE
EAT ENTERING AIR TEMPERATURE MCA MINIMUM CIRCUIT AMPACITY VAV VARIABLE AIR VOLUME
EC EGGCRATE MD MOTORIZED DAMPER VD VOLUME DAMPER
EER ENERGY EFFICIENCY RATIO MIN MINIMUM VFD VARIABLE FREQUENCY DRIVE
EF EXHAUST FAN M-M MACDONALD-MILLER W DUCT INSULATION WRAP
ELEV ELEVATION NC NORMALLY CLOSED W/ WITH
ESP EXTERNAL STATIC PRESSURE NIC NOT IN CONTRACT WELD WELDED
EWT ENTERING WATER TEMPERATURE NO NORMALLY OPEN Ø VOLTAGE PHASE & DUCT DIAMETER
HVAC SYSTEM ABBREVIATIONS
ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME
COMB-GALV COMBUSTION AIR EA AL EXHAUST ALUMINUM OA OUTSIDE AIR
SA SUPPLY AIR LP EA SS EXHAUST SS 304 OA-KOOL OUTSIDE AIR KOOLDUCT
SA-KOOL SUPPLY AIR LP KOOLDUCT EA AL WELD EXHAUST ALUMINUM WELDED RLF RELIEF AIR
SA AL SUPPLY AIR LP ALUMINUM EA GALV WELD EXHAUST GALV WELDED RA RETURN AIR
SA SS SUPPLY AIR LP SS 304 2B EA GLVNL WELD EXHAUST GALVANNEAL WELDED DB DUCTBOARD SA AL WELD SUPPLY AIR LP ALUMINUM WELDED EA SS WELD EXHAUST SS 304 WELDED FLU-CAT1 FLUE VENT - CATEGORY 1 SA GALV WELD SUPPLY AIR MP GALV WELDED EA BI GREASE EXHAUST GREASE BLACK IRON WELD FLU-CAT4 FLUE VENT - CATEGORY 4 SA GLVNL WELD SUPPLY AIR MP GALVANNEAL WELD EA GALV GREASE EXHAUST GREASE GALV WELDED FLU-CPVC FLUE VENT - CPVC MATERIAL SA SS WELD WELDED SUPPLY AIR LP SS 304 2B EA GALV GREASE EXHAUST GREASE SS 304 WELDED FLU-SS FLUE VENT - SHOP BUILT SS 304
EA EXHAUST AIR MUA MAKE-UP AIR FLU-GALV FLUE VENT - SHOP BUILT GALV
HVAC SYMBOL LEGEND
DESCRIPTION SYMBOL DESCRIPTION SYMBOL
BARE RECTANGULAR SHEETMETAL FLEX DUCT
SOUNDLINE SHEETMETAL (GENERAL NOTES) EQUIPMENT FLEX ROUND CONNECTOR
SHEETMETAL W/ INSULATION (GENERAL NOTES) EQUIPMENT FLEX RECTANGULAR CONNECTOR
BARE ROUND SHEETMETAL SUPPLY DUCT UP/DOWN
ROUND SHEETMETAL W/ INSULATION (GENERAL NOTES) EXHAUST DUCT UP/DOWN
BARE OVAL SHEETMETAL RETURN DUCT UP/DOWN
OVAL SHEETMETAL W/ INSULATION (GENERAL NOTES) SUPPLY AIR TERMINAL RECTANGULAR AND SQUARE
EXAMPLE OF EXISTING RETURN AIR TERMINAL RECTANGULAR AND SQUARE
EXAMPLE OF DEMO EXHAUST AIR TERMINAL RECTANGULAR AND SQUARE
EXAMPLE OF NEW RADIAL AIR TERMINAL
EXAMPLE OF FUTURE (N.I.C.) SUPPLY AIR SLOT DIFFUSER
EXPOSED QUALITY SHEETMETAL RETURN AIR SLOT DIFFUSER
CLEANROOM QUALITY DUCTWORK EXHAUST AIR SLOT DIFFUSER
DUCTBOARD (1" FIBERGLASS) POINT OF CONNECTION
CONTINUATIION OF ROUND DUCT CENTER LINE
CONTINUATION OF RECTANGULAR DUCT THERMOSTAT
AIR FLOW IN SYMBOL CARBON MONOXIDE SENSOR
AIR FLOW OUT SYMBOL NITROGEN DIOXIDE SENSOR
MECHANICAL EQUIPMENT TAG OTHER SENSOR
KEYED NOTE ELECTRICAL SWITCH
ACCESS DOORS MITERED ELBOW WITH TURNING VANES
RATED ENCLOSURE
NOTE: SIZE REFLECTS ACTUAL SHEET METAL DIMENSION AND DOES NOT ACCOUNT FOR INSULATION OR LINING
SEQUENCE OF OPERATION
EF-R-34: EXHAUST FAN
SCHEDULE: 24/7 CONTINOUS OPERATION
SERVES: FUME HOOD FH130, FH-131, FH-132, GB-101, GB-102, GB-103
CONTROL TYPE: STAND ALONE, CONTINUOUS OPERATION
EMERGENCY POWER: YES
SEQUENCE:
FAN SHALL MAINTAIN CONSTANT EXHAUST AIRFLOW BASED ON FUME HOOD AND GLOVE BOX DAMPER POSITIONS THAT WERE SET DURING BALANCING. EXHAUST FAN SHALL OPERATE 24/7, 365
DAYS A YEAR.
VAV-1-02: SINGLE DUCT VAV BOX
SCHEDULE: 24/7 OPERATION
SERVES: DU LAB
CONTROL TYPE: DDC SYSTEM
EMERGENCY POWER: NO, BUT VAV DAMPER SHALL FAIL OPEN IN POWER LOSS EVENT.
SEQUENCE:
PROVIDE CONSTANT VENTILATION AIR DURING OCCUPED HOURS. MECHANICAL COOLING PROVIDED BY HVU-1-01, WHICH WILL MODULATE COOLING AS NECESSARY TO MEET LOAD. IN HEATING, THE SUPPLEMENTAL HEATER WILL MODULATE AS NEEDED TO MAINTAIN THE SETPOINT.
VAV-1-06: SINGLE DUCT VAV BOX
SCHEDULE: MON - FRI 6:00 AM - 6:00 PM, SAT-SUN OFF (ADJUSTABLE)
SERVES: WAREHOUSE SOUTHEAST
CONTROL TYPE: DDC SYSTEM
SEQUENCE:
BOX SHALL MAINTAIN VENTILATION MINIMUM DURING OCCUPIED HOURS, MODULATING HEATING AND COOLING AS NECESSARY TO MAINTAIN TEMPERATURE SETPOINT.
SEQUENCE OF OPERATION
EXISTING DEDICATED OUTDOOR AIR SYSTEM UNITS (HVU-1-02 THRU HVU-1-03)
SCHEDULE: 24/7 CONTINOUS OPERATION
SERVES: BUILDING
CONTROL TYPE: DDC SYSTEM
NOTES: PROVIDES 2015-WASHINGTON STATE MECHANICAL CODE MINIMUM VENTILATION AIR REQUIREMENTS FOR ALL SPACES.
OPERATION SUMMARY: SINCE DOAS UNITS PROVIDE MAKEUP AIR FOR RADIOISOTOPE FUME HOODS WHICH RUN CONTINOUSLY, OCCUPIED MODE SHALL BE SET FOR 24/7, 365 DAYS PER YEAR FOR
CONTINUOUS OPERATION.
SEQUENCE:
VFD'S SHALL MODULATE FAN SPEED FOR VARIABLE VOLUME SUPPLY FANS BASED ON DUCT STATIC PRESSURE SENSORS.
THE BAS SHALL SUPPLY A CONSTANT SUPPLY AIR TEMPERATURE AT ALL TIMES TO ENSURE THAT LAB SPACE TEMPERATURES REMAIN CONSTANT.
UNITS ARE PROVIDED WITH SUPPLEMENTAL GAS HEAT, ECONOMIZER COOLING AND DX COOLING.
SUPPLEMENTAL GAS HEAT TO BE STAGED AND CONTROLLED USING SUPPLY AIR TEMPERATURE SENSOR TO MAINTAIN A CONSTANT SUPPLY AIR TEMPERATURE OF 72°F (ADJ).
ECONOMIZER COOLING AND DX COOLING TO BE CONTROLLED USING SUPPLY AIR TEMPERATURE SENSOR TO MAINTAIN A CONSTANT SUPPLY AIR TEMPERATURE OF 72°F (ADJ).
EXISTING DEDICATED OUTDOOR AIR SYSTEM UNIT (HVU-1-01)
SCHEDULE: 24/7 CONTINOUS OPERATION
SERVES: WAREHOUSE AND DU LAB
CONTROL TYPE: DDC SYSTEM
NOTES: PROVIDES 2018-WASHINGTON STATE MECHANICAL CODE MINIMUM VENTILATION AIR REQUIREMENTS FOR ALL SPACES.
OPERATION SUMMARY: SINCE DOAS UNITS PROVIDE MAKEUP AIR FOR FUME HOODS WHICH RUN CONTINOUSLY, OCCUPIED MODE SHALL BE SET FOR 24/7, 365 DAYS PER YEAR FOR CONTINUOUS OPERATION.
SEQUENCE:
DURING OCCUPIED MODE, THE OUTDOOR AIR DAMPERS AND RETURN AIR DAMPERS SHALL BE OPEN AND MODULATE AS NEEDED. THE VFD'S SHALL MODULATE FAN SPEED FOR VARIABLE VOLUME SUPPLY BASED ON COOLING, HEATING, AND DUCT STATIC PRESSURE SETPOINTS. THE THERMOSTAT IN THE DU LAB SHALL DETERMINE HEATING/COOLING SUPPLY AIR TEMPERATURE NEEDED TO MAINTAIN 72°F SPACE TEMPERATURE, WITH THE WAREHOUSE THERMOSTAT TAKING SECONDARY PRIORITY. IN COOLING MODE, THE UNIT SHALL STAGE THE ECONOMIZER AND DX COOLING AS NEEDED. THE WAREHOUSE VAV'S (CURRENTLY VAV-1-06) WILL MODULATE DOWN TO HVU MINIMUM IF SPACES ARE SATISFIED. IN HEATING MODE, THE GAS HEAT SHALL STAGE AS NEEDED TO MAINTAIN OCCUPIED SETPOINT.
VRF SYSTEM (CU-R-14) AND INDIVIDUAL ZONE CEILING CASSETTES (CC-1-9A THRU CC-1-9D)
SCHEDULE: 24/7 CONTINOUS OPERATION
SERVES: NA/CHEM LAB 125
CONTROL TYPE: PROPRIETARY VRF CONTROLS W/REMOTE WALL MOUNTED THERMOSTAT
DDC SYSTEM INTERFACE: MONITORING AND ALARM ONLY FOR SYSTEM STATUS.
OPERATION SUMMARY: CEILING CASSETTES OPERATE TO MAINTAIN ZONE SPACE TEMPERATURE SETPOINT OF 72°F (ADJ.) INDEPENDENT OF OCCUPANCY SCHEDULE.
DUCTLESS SPLIT SYSTEM HEAT PUMP (CU-R-15/CC-1-10) (CU-R-16/CC-1-11)
SCHEDULE: 24/7 CONTINOUS OPERATION
SERVES: MICROSCOPY LAB 126, ANALYTIC LAB 123
CONTROL TYPE: STAND ALONE W/REMOTE WALL MOUNTED THERMOSTAT
DDC SYSTEM INTERFACE: MONITORING AND ALARM ONLY FOR SYSTEM STATUS.
OPERATION SUMMARY: CEILING CASSETTES OPERATE TO MAINTAIN ZONE SPACE TEMPERATURE SETPOINT OF 72°F (ADJ.) INDEPENDENT OF OCCUPANCY SCHEDULE.
DUCTED SPLIT SYSTEM HEAT PUMP (CU-R-13/FC-1-09)
SCHEDULE: 24/7 CONTINOUS OPERATION
SERVES: RADIOCHEM LAB 124
CONTROL TYPE: STAND ALONE W/REMOTE WALL MOUNTED THERMOSTAT
DDC SYSTEM INTERFACE: MONITORING AND ALARM ONLY FOR SYSTEM STATUS.
OPERATION SUMMARY: FAN COIL UNIT OPERATES TO MAINTAIN ZONE SPACE TEMPERATURE SETPOINT OF 72°F (ADJ.) INDEPENDENT OF OCCUPANCY SCHEDULE.
EF-R-18: EXHAUST FAN
SCHEDULE: MON - FRI 6:00 AM - 6:00 PM, SAT-SUN OFF (ADJUSTABLE)
SERVES: ANALYTIC LAB 123
CONTROL TYPE: WALL MOUNTED SWITCH
NOTES: PROVIDES CONSTANT AIRFLOW
DDC SYSTEM INTERFACE: MONITORING AND ALARM ONLY FOR SYSTEM STATUS.
EMERGENCY POWER: NO
SEQUENCE:
FAN SHALL MAINTAIN CONSTANT EXHAUST AIRFLOW BASED ON BALANCING DAMPER POSITIONS THAT WERE SET DURING BALANCING. FAN SHALL BE OFF DURING UNOCCUPIED HOURS.
INTERLOCK MOTORIZED DAMPER TO OPEN WHEN FAN IS ENERGIZED.
EF-R-19, EF-R-20: EXHAUST FANS
SCHEDULE: MON - FRI 6:00 AM - 6:00 PM, SAT-SUN OFF (ADJUSTABLE)
SERVES: NA/CHEM LAB 125 & TREAT
CONTROL TYPE: WALL MOUNTED SWITCH
NOTES: PROVIDES CONSTANT AIRFLOW
DDC SYSTEM INTERFACE: MONITORING AND ALARM ONLY FOR SYSTEM STATUS.
EMERGENCY POWER: NO
SEQUENCE:
FAN SHALL MAINTAIN CONSTANT EXHAUST AIRFLOW BASED ON FUME HOOD BALANCING DAMPER POSITIONS THAT WERE SET DURING BALANCING. FAN SHALL BE OFF DURING UNOCCUPIED HOURS.
INTERLOCK MOTORIZED DAMPER TO OPEN WHEN FAN IS ENERGIZED.
EF-R-21: EXHAUST FAN
SCHEDULE: 24/7 CONTINOUS OPERATION
SERVES: RADIOCHEM LAB 124 FUME HOODS - FH-101 AND FH-102
CONTROL TYPE: BMS
NOTES: PROVIDES CONSTANT AIRFLOW
DDC SYSTEM INTERFACE: STATUS/ON/OFF
EMERGENCY POWER: YES
SEQUENCE:
FAN SHALL MAINTAIN CONSTANT EXHAUST AIRFLOW BASED ON FUME HOOD BALANCING DAMPER POSITIONS THAT WERE SET DURING BALANCING. FAN SHALL OPERATE 24/7, 365 DAYS A YEAR.
VAV-1-XX, SVAV-1-XX: SINGLE DUCT VAV BOXES
SCHEDULE (SVAV-1-05): 24/7 CONTINOUS OPERATION.
SCHEDULE (ALL OTHERS): MON - FRI 6:00 AM - 6:00 PM, SAT-SUN OFF (ADJUSTABLE)
SERVES: SINGLE ZONE SPACES
CONTROL TYPE: DDC SYSTEM
NOTES: PROVIDES VENTILATION AIR DURING OCCUPIED HOURS. SVAV-1-05: PROVIDES CONSTANT AIRFLOW TO RADIOCHEM LAB 124 24/7, 365 DAYS A YEAR. ALL OTHERS: VAV BOX SHALL BE AT MINIMUM AIRFLOW POSITION IF ASSOCIATED EXHAUST FAN IS OFF. VAV BOX SHALL BE AT MAXIMUM AIRFLOW POSITION IF ASSOCIATED EXHAUST FAN(S) IS ON. SVAV-1-06 WILL REQUIRE (3) DIFFERENT POSITIONS
SINCE THERE ARE (2) EXHAUST FANS SERVING THAT ZONE.
ASSOCIATED EXHAUST FANS:
VAV-1-01: EF-R-18
SVAV-1-05: EF-R-21
SVAV-1-06: EF-R-19, EF-R-20
ARGON GAS MATERIAL SCHEDULE
PIPING AND VALVE MATERIAL SCHEDULE:
LOCATION PIPING SIZE MATERIAL/PART NO. JOINT
ABOVE GROUND
ARGON GAS (350 PSIG) ALL ASTM B 819 COPPER TYPE L 95/5 SWEAT
SHUT-OFF VALVES (600 PSIG) 1/4" TO 1" APOLLO MODEL 77C-101-01A THRU 77C-105-01A FNPT X FNPT
1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES
AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
2. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS.
3. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2018 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES.
4. THIS SCOPE ENDS AT THE SUPPLY SHUT-OFF VALVE FOR EQUIPMENT CONNECTION BY OTHERS. ALL FINAL CONNECTIONS AND REQUIRED APPURTANCES ARE BY OWNER.
5. PRESSURE REGULATOR(S) AND PRESSURE GUAGES ARE FURNISHED AND INSTALLED BY OWNER
6. UNLESS OTHERWISE SHOWN, INSTALL ALL VALVES POINTING DOWNWARD.
7. CTS HANGERS SHALL BE ATTACHED TO THE TOP CORDS OF TRUSSES
8. PROVIDE SHUT-OFF VALVES AT ALL EQUIPMENT CONNECTIONS.
9. AT ALL VALVES NOT CONNECTED TO EQUIPMENT, PROVIDE A BRASS PLUG.
10. BASIS OF DESIGN: DESIGN PRESSURE - 350 PSIG; NOMINAL WORKING PRESSURE - 225 PSIG; SAFETY RELIEF 300 PSIG.
11. PROVIDE ANSI STANDARD PIPE MARKERS ("ARGON - 225 PSIG" AFTER PRESSURE REGULATOR) AND VALVE TAGS. REFER TO PLANS FOR VALVE TAG NUMBERS.
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
0_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:2
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
SC
H
ED
U
LE
S
TM0.02
H
SEAWAY BLVD
153'-4"
9'-
221'-0"
568'-6"
TH
A
VE
W
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
0_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:3
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
SI
TE
P
LA
N
TM0.01S
NTS
N
K-12793HOLLISTERC_SINKSVITREOUS CHINA
ARGON
ARGON
FCU-1-07
FCU-1-06
14x14SA 14x14SA UP
UP TO
14x14SA UP
7'-6" 6'-4"
10'-4" 9'-2"
24x24
26x26
10'-4" 9'-2"
14x14SA
UP TO
14x12SA UP 14x12SA
14x12SA UP
14x12SA
7'-6" 6'-4"
24x24
26x26
14x14
10ØRA UP 11'-4"
10'-6"
12x20RA UP
12x20SA UP
11'-10" 10'-2"
20x12RA
20x12SA
11'-6" 10'-6"
20x12SA
20x12RA x1
2R A
12x12RA
24x24
24x24
FCU-1-02
UP TO
12ØSA
24x24
24x24
ØSA
Ø
SA
24x24
24x24
10ØSA
10ØSA
8Ø
SA
Ø
SA
12ØSA 12ØSA
FCU-1-01
UP TO
24x24
24x24
12x10RA x10
SA
10ØSA10
Ø
SA
24x24
24x24
24x24
10ØRA UP
12x10RA UP 12x10SA UP
11'-4" 10'-6"
11'-4" 10'-6"
12'-4" 11'-10"
11'-6" 10'-6"
6Ø
RA
14x14
11'-4" 10'-6"
RA
14x14
RA
14x14
RA
24x24
22x12RA
12x12RA
12x12RA 14ØSA UP
14ØRA UP
24x24
24x24
FCU-1-05
UP TO
24x24
8Ø
RA 12'-4"
11'-8"
8ØRA
8Ø
RA
24x24
8ØSA
12'-4" 11'-8"
8Ø
SA
8ØSA
8ØSA
6ØSA DN
6ØSA DN
6ØSA DN 12'-4"
11'-8"
FCU-1-04
UP TO
11'-4" 10'-8"
11'-4" 10'-8"
11'-6" 10'-6"
11'-6" 10'-6"
11'-4" 10'-8"
FCU-1-03
UP TO
8ØRA 8ØRA
12'-8" 12'-0"
10x10
10x10
8Ø
RA
16x12RA
12ØRA
12ØRA
24x24
24x24
11'-8" 10'-4" 16x12RA UP
16x12SA UP
11'-6" 10'-6" x1
2S A
16x12SA
10ØSA 10ØSA
24x24
24x24
8Ø
SA
8Ø
SA
8Ø
SA
24x24
24x24
24x24
24x24
TYP(2)
RA
24x24
16x12SA
24x24
24x24
Ø
SA
Ø
SA
12ØSA
24x24
11'-6" 10'-6"
24x24
16x12RA UP 16x12SA UP
16x12RA
TYP(2)
RA
14x14
12ØSA UP
12ØSA UP
12ØRA UP
EVAV-1-03
16'-6" 15'-4"
24x24
24x24
14ØSA UP
14ØSA UP
24x24
14ØSA UP
24x24
14ØSA UP
128-FH-1
1800 CFM
14ØEA
EVAV-1-06
14ØEA
12x24EA UP 24x12EA
24x12EA
14ØEA
EVAV-1-05
12ØEA UP
500 CFM
100-SN-1
100-FH-3
(FUTURE)
100-SN-2
(FUTURE)
100-SN-3
(FUTURE)
100-SN-4
(FUTURE)
100-SN-5
(FUTURE)
100-SN-6
(FUTURE)
100-SN-7
(FUTURE)
100-SN-8
(FUTURE)
100-SN-9
(FUTURE)
(TYP 2)
TA
24X16B
14X14 EA UP WITH BIRDSCREEN AT
OPENING - 750 CFM
(TIGHT TO STRUCTURE)
11 2
FD
-1
44x30SA UP
52x34W RA ROUTED
BELOW SA.
14'-0" 11'-6"
44x30W SA
MIN R-8 INSULATION REQUIRED
FOR SUPPLY/RETURN DUCT
LOCATED OUTSIDE.
16' AFF
GB-2
GB-3
GB-1
FH-130
FH-131
FH-132
FURNACE
(TYP 6)
16X16A
26ØSA 20ØSA
20ØSA
Ø
SA
3'-0"
ØSA
14ØSA
14ØSA
14ØSA
14ØSA
10Ø EA UP
TO EF-R-34
12Ø EA UP TO EF-R-34
6Ø EA UP TO EF-R-34
6ØEA
6Ø EA DOWN
TO GB-3 6Ø EA DOWN
TO GB-2
VAV-1-02
KEYED NOTES
PLACE DAMPER IN DUCTWORK
ABOVE EQUIPMENT.
6Ø EA DUCT FROM GB-2 TO
CONNECT WITH 6Ø EA DUCT
FROM GB-3 AND DUCT TO RISE UP
TO EF-33
OWNER PROVIDED FUME HOOD
TO BE BALANCED TO 800 CFM
EACH.
OWNER PROVIDED GLOVE BOX
TO BE BALANCED TO 200 CFM
EACH.
20ØSA MP UP
TO HVU-1-01
TM6.01 T
T
TO VAV-1-06
x3
4W R
A 34x52W RA x3
0W S
A
14ØSA
14ØSA
KEY PLAN
A B
1/8" = 1'-0"
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
2_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:3
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
1S T
FL
O
O R
P
AR
TI
AL
P
LA
N
TM2.01A
H
VA
14x14SA DN
12'-2" 11'-0"
FCU-1-07
FCU-1-06
14x14SA
54x8SA
54x8SA
14x14SA DN 14x14SA
14x12SA DN
14x12SA
54x8SA
14x12SA
54x8SA
12'-0" 11'-0"
14x12SA DN
10ØRA DN
12x20RA DN
12x20SA DN
10ØRA DN
12x10RA DN 12x10SA DN
12ØSA DN
8ØRA
FCU-1-01
x1
0S A
12x10RA x1
0R A
34x10SA 36x14RA 12'-0" 11'-0"
Ø
SA
8ØRA
12ØSA
12ØRA
16ØSA
16ØRA
FCU-1-0210
Ø
RA
20x12RA
42x14RA40x10SA
8Ø
RA
8ØRA
12'-0"
11'-0" 14ØRA 14
x1 4R
A x1 4S
A
12ØSA
FCU-2-01
17'-4" 15'-8"
14'-8" 13'-0"
34x10SA
36x14RA
12'-0" 11'-0"
40x16RA UP
TO DOAS
40x16SA UP
TO DOAS
12ØRA DN
10ØRA DN
20'-9" 19'-1"
Ø
RA
Ø
SA
12ØRA
12ØRA DN
20ØSA
20ØRA
16ØSA
16ØRA
12ØSA DN
12'-0" 11'-0"16 x1 4S
A
12ØSA
12ØSA
FCU-2-02
14ØRA
x1
4R A 42x14RA
40x10SA
14'-6" 13'-2"
17'-2" 15'-10"
12ØSA
Ø
RA
16ØSA
16ØRA
16ØSA
8Ø
SA
14ØRA
x1
4R A
FCU-2-03
42x14RA
40x10SA
12ØSA16
x1
4S A 12'-0"
11'-0"
12ØSA
12ØSA
16x12RA DN 16x12SA DN x1
2R A
42x14RA
40x10RA
12'-0" 11'-0"
14ØRA DN
14ØSA DN
Ø
RA
14ØSA
FCU-1-05
FCU-1-03
12'-0" 11'-0"
FCU-2-05
36x14RA 12ØRA
34x10SA
12'-0" 11'-0"
8Ø
SA
16x12RA DN
16x12SA DN
14x14SA
12ØSA
12ØSA
14x12RA 12ØRA FCU-1-04
FCU-2-04
16x12RA
12ØRA DN
12'-0" 11'-0"
12'-1" 11'-1" 40x10SA
42x14RA
40x10SA
42x14RA
42x8RA
42x8SA
10x10
24x24
24x24
24x24
12ØSA
24x24
24x24
24x24
24x24
24x24
24x24
Ø
SA
24x24
24x24
12ØRA
24x24
24x24
24x24
8ØSA
24x24185
24x24
8Ø
RA
T
24x24200
24x24
8Ø
SA
8ØSA
T
24x24
24x24
8ØSA
24x24
24x24
8Ø
RA
24x24
12ØSA
24x24
T
24x24
24x24
24x24
24x24
T
12ØRA
14ØRA T
24x24
24x24
24x24
24x24
14ØRA
8ØSA
12x24EA DN
18ØEA
Ø
EA
HEPA-1-03
72x28EA
72x28EA
Ø
EA
x2 4E
A
12x24EA
12x24EA
DN
19'-6" 17'-6"
Ø
SA
Ø
SA
SVAV-1-03
24'-1" 22'-7"
14ØSA
14ØSA
14ØSA DN
14ØSA
DN
14ØSA DN
14ØSA DN
Ø
SA
CAP
VAV-1-05
VAV-1-04
VAV-1-03
Ø
SA
Ø
SA
Ø
SA
24ØSA24ØSA
Ø
SA
Ø
SA
12Ø UP/DN
(FUTURE)
25'-1" 24'-1" 12Ø
(FUTURE)
12Ø
(FUTURE)
18Ø UP
(FUTURE)
14X14 EA UP
(TIGHT TO STRUCTURE)
VAV-1-06
44x30SA DN
46ØSA
34ØSA
18ØEA
6ØEA
EA
6Ø
6ØEA
4'- 0"
10Ø EA DN
TO FH-130
12Ø EA DN TO FURNACE
6Ø EA DN TO GB-1
6Ø EA DOWN TO
GB-2 AND GB-3
10Ø EA DN
TO FH-131
10Ø EA DN
TO FH-132
22Ø EA UP TO EF-R-34
TRANSITION DN TO 18Ø EA
20Ø MP DN TO VAV-1-02
36X12B
36X12B
36X12B
CAP
CAP
T
KEY PLAN
A B
1/8" = 1'-0"
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
2_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:5
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
2N D
F
LO
O R
P
AR
TI
AL
P
LA
N
TM2.02A
H
VA
48"x48" ROOF
ACCESS HATCH
CU-R-11
CU-R-12
ERV-R-1
40x16RA DN 40x16SA DN
40x16 RA INLET
MANUFACTURER PROVIDED 40x16
EXHAUST COWLING, PROVIDE BIRD
SCREENING AT OUTLET.
MANUFACTURER PROVIDED 50x20
INTAKE COWLING WITH DOWNTURN.
PROVIDE BIRD SCREENING AT OUTLET.
CU-R-01
CU-R-02
CU-R-05 CU-R-06 CU-R-07 CU-R-03
CU-R-10
CU-R-09
CU-R-04
CU-R-08
EF-R-28
12Ø DN
(FUTURE)
(FUTURE)
RV-R-3
(FUTURE)
RV-R-2RV-R-1
EF-R-14
18Ø DN
(FUTURE)
(FUTURE)
EF-R-11
18Ø DN
(FUTURE)
(FUTURE)
EF-R-15
18Ø DN
(FUTURE)
(FUTURE)
EF-R-31MIN 10'
14X14EA DN
10' FROM OPERABLE OPENING INTO THE BUILDING
6FT FROM EXTERIOR WALLS
EF-R-34
10' HIGH DISCHARGE STACK 16Ø
EA DUCT.
NEW EXHAUST FAN TO BE INSTALLED PER MANUFACTURER
RECOMMENDATIONS. COORDINATE EXACT LOCATION FOR
VARIABLE FREQUENCY DRIVE WITH GC AND EC.
22ØEA
TRANSITION TO 16Ø INLET
NEW FAN TO BE MOUNTED ON
SLEEPERS PROVIDED BY GC. ROOFING
BY OTHERS.
TM6.01
TM6.01
TM6.01
15'-0"
31'-7"
KEY PLAN
A B
1/8" = 1'-0"
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
2_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:3
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
R O
O F
PA
R
TI
AL
P
LA
N
TM2.03A
H
VA
EF-R-29
'-0
12" DISCHARGE STACK
W/ 8" NOZZLE
EF-R-29
12" DISCHARGE STACK
W/ 8" NOZZLE
'-0
60'-0"
6'-
0" PROPERTY LINE
LINE OF SIGHT
16Ø EXHAUST WITH FIELD FABRICATED DUCT
STACK RISING TO 10', MAINTAIN 16Ø DUCT TO
OBTAIN 3000 FPM DISCHARGE.
106'-0"
6'-
0" PROPERTY LINE
LINE OF SIGHT
'-0
22'
16Ø EXHAUST WITH FIELD FABRICATED DUCT
STACK RISING TO 10', MAINTAIN 16Ø DUCT TO
OBTAIN 3000 FPM DISCHARGE.
31'-7"
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
3_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:4
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
EL
EV
AT
IO
N S
TM3.01
H
TM6.01 FUME HOOD EXHAUST FAN DETAIL
N.T.S.
MAINTAIN 16Ø DUCT TO OBTAIN
3000 FPM DISCHARGE.
COORDINATE DUCT RISER
SUPPORTS W/G.C.
FLANGED CONNECTION W/EPDM
GASKET.
STEEL FAN BASE
SEISMIC VIBRATION ISOLATORS:
AS REQUIRED
SLEEPERS OR PAD
PROVIDED BY G.C
NOTE: COORDINATE EQUIPMENT SUPPORT LOCATION WITH STRUCTURAL ENG & G.C
MINIMUM 10'
ABOVE THE
ADJACENT
ROOF/PARAPET
TM6.01 VAV BOX DETAIL
N.T.S.
DUCT
DUCT HANGER
(TYP)
THREE DUCT DIAMETERS
MINIMUM STRAIGHT DUCT
VAV BOX
TRANSITION IF REQUIRED
SAME SIZE AS INLET SHEET METAL DUCT W/
1" ACOUSTICAL LINING
SUPPLY AIR DUCT
3'-0" MIN TO
FIRST OUTLET
TM6.01
ROOFTOP EQUIPMENT
SLEEPER SUPPORT DETAIL
N.T.S.
ROOF
22 GAUGE GALV SLEEPER
CAP BY M.C.
ANCHOR TO STRUCTURE
ROOFING EXTENDED UP (4)
SIDES OF SLEEPER
BY G.C.
CANT STRIP
AND ROOFING
BY G.C.
EQUIPMENT SLEEPER,
BY G.C. LOCATION
LAYOUT BY M.C.
DRIP EDGE
TM6.01 STACK GUY-WIRE DETAIL
N.T.S.
PLAN VIEW
NOTE:
ANCHOR GUY LINES PER
STRUCTURAL REQUIREMENTS.
ELEVATION
ROOF
GUY WIRES SPACED 120'
STACK
CABLE CLAMP
STACK
SSTL CABLES QTY & SIZE
AS REQUIRED
INTERMEDIATE BRACING AS
REQUIRED.
TERMINATE PER PLANS
EQ
UA
L
EQUAL
'-0
M
AX
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TM
6_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:0
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
D
ET
AI
LS
TM6.01
H
ARGON
ARGON
3/4"NG TO WH-1-01
1/2"NG-22' AFF
2"NG TO METER
GAS METER
ASSEMBLY 2"NG-22' AFF 2"NG-22' AFF
DROP DOWN COLUMN WITH 1/2".
PROVIDE TEE AND (2) 1/2" S.O.V.S.
3/4" @ CLG.
1/2"1/2"
3/4" @ CLG. WITH CTS
HANGERS
3/4" @ CLG. SUPPORT
FROM WALL
DROP DOWN WALL WITH 1/2".
PROVIDE 1/2" S.O.V. 1" @ CLG. SUPPORT
FROM WALL
1/2" S.O.V.
AT 3'-0" AFF
DROP DOWN WALL WITH 3/4".
PROVIDE 1/4" & 3/4" S.O.V.
1" @ CLG.
P.R.V SET FOR 225 PSIG OUTLET PRESSURE AND
RATED FOR 60 SCFM. PVR IS OF/OI
1" IET/EVL CONNECTION VALVE (LOCKABLE)
AT 3'-0" AFF
1" S.O.V.
1/2"
3/4" 3/4"1/4"
1"
RISE TO CEILING HEIGHT AND
SUPPORT FROM WALL.
PENETRATE EXTERIOR
WALL AND SEAL.
START CTS
HANGERS
1" @ CLG. SUPPORT
FROM WALL
PROVIDE CTS HANGERS AND
INSTALL ABOVE OVERHEAD
DOOR SUPPORTS
EVL-AR-100S-103
EVL-AR-100S-1041/4"
3/4" EVL-AR-100S-105
EVL-AR-100N-101 EVL-AR-100N-100
EVL-AR-100N-102
GRADE
SLOPE
EL. 14'-4" ABOVE
GRADE AT
BUILDING LINE
1" ARGON - SUPPORT OFF
CROSS ARMS FURNISHED
& INSTALLED BY OTHERS.
P P
ARGON DEWAR
PRESSURE SAFETY
RELIEF BY OWNER
UPSTREAM OF SHUT-OFF VALVE
EVL-AR-OUT-103
PRESSURE GAUGES
(OF/OI)
EVL-AR-OUT-101
PRESSURE GAUGES
(OF/OI)
POC WITH SHUT-OFF
DOWNSTREAM OF DEWAR
SAFETY RELIEF
EVL-AR-OUT-102
EL. 14-7" ABOVE
GRADE AT ARGON TANK
ARGON DEWAR
OF/OI (350 PSIG).
300 PSIG
PRESSURE SAFETY
RELIEF BY MMFS
EVL-AR-OUT-100
EVL-AR-100N-103
EVL-AR-100S-102 EVL-AR-100S-101
EVL-AR-100S-100
1" @ CLG.
1 1/4"CD UP
1 1/4"CD UP
1 1/4"CD TERMINATING WITH 1"
AIRGAP ABOVE JANITORS SINK
1 1/4"CD UP
1 1/4"CD TERMINATING WITH 1"
AIRGAP AT TAIL PIECE OF SINK
DEMO 1/2" ARGON
VALVE AND
REPLACE WITH
NEW 3/4" VALVE.
3/4" ARGON
3/4" ARGON
3/4" ARGON
KEYED NOTES
1/2" ARGON CONNECTION DROP DOWN
TO OWNER-PROVIDED EQUIPMENT
WITH SHUT-OFF VALVE.
1 1/2"NG-8' AFF
1 1/2"NG TO HVU-1-01
KEYED NOTES
PROVIDE GAS PRESSURE REGULATOR,
SHUT-OFF VALVE AND UNION TO MATCH
PIPING CONNECTION TO HVU-1-02.
PROVIDE 1-1/4"Ø SOLID WALL PVC 6" HIGH
TRAP WITH UNION AT EQUIPMENT
CONNECTION. MATCH ROUTING TO HVU-1-02.
1 2
EARTHQUAKE VALVE
KEY PLAN
A B
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TF
2_
.d w g W ed ne sd ay
, A pr il
, 2
8:
:1
AM
DPD STAMP
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S w w w .m ac m ille r.c om
In tl.
B lv d.
S ui te
, S ea
Ta c, W A
Ph on e:
-7
-9
TE
R
R A
PO
W
ER
E
VE
R
ET
T
TE
R
R A
PO
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A.
R
EC
O R
D D
R
AW
IN
G
S
D-3984-72225020-00
A ZBOROWSKI
G GRAHAM
F MAMERTO
04-11-23
04-11-23
11-04-22
-0
4-
PE
R
M
IT
/C D
S
ET
-1
1-
R
EC
O R
D S
ET
A
1S T
FL
O
O R
P
AR
TI
AL
P
LA
N
TF2.01A
FI
TT
IN
G
1/8" = 1'-0"
SITE
3315 SEAWAY BLVD
EVERETT, WA 98203
I-5
I-5
HWY 2
POSESSION
SOUND
US NAVAL
STATION
EVERETT
SN
O
HO
M
IS
H
RI
VE
R
VICINITY MAP
NO SCALE
1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE LAB GAS PIPING CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO
VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
2. RECEIVING, SETTING AND SEISMIC REQUIREMENTS FOR OWNER FURNISHED EQUIPMENT IS BY OTHERS.
3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS.
4. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH SECTION 313 AND TABLE 313.3 OF THE 2015 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS.
5. THIS SCOPE ENDS AT THE SUPPLY SHUT-OFF VALVE FOR EQUIPMENT CONNECTION BY OTHERS. ALL FINAL CONNECTIONS AND REQUIRED APPURTANCES ARE BY OWNER.
6. PRESSURE REGULATOR(S) AND PRESSURE GUAGES ARE FURNISHED AND INSTALLED BY OWNER.
7. UNLESS OTHERWISE SHOWN, INSTALL ALL VALVES POINTING DOWNWARD.
8. CTS HANGERS SHALL BE ATTACHED TO THE TOP CORDS OF TRUSSES
9. AT ALL VALVES NOT CONNECTED TO EQUIPMENT, PROVIDE A BRASS PLUG.
10. BASIS OF DESIGN: DESIGN PRESSURE - 350 PSIG; NOMINAL WORKING PRESSURE - 225 PSIG; SAFETY RELIEF 300 PSIG.
11. REFER TO "LAB GAS SYSTEM TESTING SCHEDULE" FOR SYSTEM COMMISSIONING REQUIREMENTS.
12. PROVIDE ANSI STANDARD PIPE MARKERS ("ARGON - 225 PSIG" AFTER PRESSURE REGULATOR) AND VALVE TAGS. REFER TO PLANS FOR VALVE TAG NUMBERS.
LAB GAS GENERAL NOTES
PIPING AND VALVE MATERIAL SCHEDULE:
LOCATION PIPING SIZE MATERIAL/PART NO. JOINT
ABOVE GROUND
ARGON (350 PSIG) 1/2" TO 1" TYPE L COPPER 95/5 SWEAT
PRESSURE RELIEF VALVE (300 PSIG) 1" APOLLO MODEL 19M-E-E-K-300-Q MNPT X FNPT
SHUT-OFF VALVES (600 PSIG) 1/4" TO 1" APOLLO MODEL 77C-101-01A THRU 77C-105-01A FNPT X FNPT
DRAWING SHEET INDEX
NAME TITLE NAME TITLE
TG0.01 SCHEDULES TG2.01B FIRST FLOOR NORTH PLAN - ARGON PIPING
TG2.01A FIRST FLOOR SOUTH PLAN - ARGON PIPING
LAB GAS SCOPE OF WORK
INSTALL NEW 225 PSIG ARGON LAB GAS SYSTEM FROM OWNER'S DEWAR TO EQUIPMENT SHUT-OFF VALVES. PROVIDE SYSTEM PRESSURE TEST AND COMMISIONING.
CONTACT LIST
TITLE NAME COMPANY PHONE NUMBER EMAIL
DESIGN ENGINEER MICHAEL CURTRIGHT MACDONALD MILLER 206-768-4146 MICHAEL.CURTRIGHT@MACMILLER.COM ACCOUNT MANAGER KEVIN ANWAY MACDONALD MILLER 206-768-4102 KEVIN.ANWAY@MACMILLER.COM PLUMBING SUPERINTENDENT KELLY KING MACDONALD MILLER 206-768-3962 KELLY.KING@MACMILLER.COM PLUMBING FOREMAN PAUL MONSEN MACDONALD MILLER 206-768-3848 PAUL.MONSEN@MACMILLER.COM
LEGAL DESCRIPTION
APN# 28040300400300
LEGAL DESCRIPTION:
SEC 03 TWP 28 RGE 04LOT 1 OF SEAWAY CENTER TWO/INTERMIC BSP REC VOL 1 PGS 181 THRU 183 AF 8910255009 & BEING PTN SE1/4
LAB GAS SYSTEM TESTING SCHEDULE PRESSURE (PSIG) PROTOCOL
SYSTEM OPERATING TEST MEDIUM DURATION
ARGON 225 L2 L1 16 HOURS
NOTES
L1 CLEAN "INDUSTRIAL GRADE" NITROGEN
L2 TEST PRESSURE: 350 PSIG. USE CALIBRATED GAUGE SIZED FOR 0 - 600 PSIG RANGE. MAXIMUM TEST PRESSURE DROP: 1 PSIG.
REFER TO DRAWING TG0.01 FOR PIPE MATERIAL, JOINT TYPE, VALVES AND OTHER SYSTEM REQUIREMENTS.
A
SC
H
ED
U
LE
S
TG0.01
G
AS
P
IP
IN
G
D
AT
E R
EV
IS
IO
N
S:
ENGINEER:
CHECKED BY:
CAD:
LAST REVISED:
DATE PLOTTED:
ISSUE DATE:
SHEET NUMBER:
D
AT
E R
EV
IS
IO
N
S:
DRAWING NUMBER:
D et ro it
Av en ue S
W
Se at tle , W
A
Ph on e:
-7
-9
Fa x:
-7
-6 w w w
.m ac m ille r.c om
W A
Li c
N o:
M
AC
D O
FS
0R U
M ac
D on al d-
M ille r
FA
C
IL
IT
Y
SO
LU
TI
O
N S
J:
\7
2\
T er ra P ow er
E ve re tt
K A\
\2
En gi ne er in g\ D
W G
\S ht s\
TG
0_
.d w g Tu es da y, A pr il
, 2
:3
5:
P M
DPD STAMP
TE
R
R
AP
O W
ER
E
VE
R
ET
T
PH
AS
E
III
R
EV
TE
R R
AP
O
W
ER
S
EA
W
AY
B
LV
D
EV
ER
ET
T, W
A
R
EC
O R
D D
R
AW
IN
G
D-3984-72192229-04
M CURTRIGHT
B GEZON
F MAMERTO
01-14-22
01-14-22
07-20-20
-1
9-
FO
R
R
EV
IE
W
-0
8-
O W
NE
R
RE
VI
EW
C
O M
M
EN
TS
-2
0-
RE
VI
SE
D
PI
PE
R O
UT
IN
G
-1
4-
RE
CO
RD
S
ET
ARGON
ARGON
DROP DOWN COLUMN WITH 1/2".
PROVIDE TEE AND (2) 1/2" S.O.V.S.
3/4" @ CLG.
1/2"1/2"
3/4" @ CLG. WITH CTS
HANGERS
3/4" @ CLG. SUPPORT
FROM WALL
DROP DOWN WALL WITH 1/2".
PROVIDE 1/2" S.O.V. 1" @ CLG. SUPPORT
FROM WALL
1/2" S.O.V.
AT 3'-0" AFF
DROP DOWN WALL WITH 3/4".
PROVIDE 1/4" & 3/4" S.O.V.
1" @ CLG.
P.R.V SET FOR 225 PSIG OUTLET PRESSURE AND
RATED FOR 60 SCFM. PVR IS OF/OI
1" IET/EVL CONNECTION VALVE (LOCKABLE)
AT 3'-0" AFF
1" S.O.V.
1/2"
3/4" 3/4"1/4"
1"
RISE TO CEILING HEIGHT AND
SUPPORT FROM WALL.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .