1-Exhibit A - Statement of Work.docx

DOCX document 364 KB Posted

Attached to
RFP-2025-8352 - Ventilation Consultant
Solicitation number
RFP-2025-8352
Issued by
Washington

About this file

This document is an Exhibit A Statement of Work from TerraPower, a nuclear innovation company located in Bellevue, Washington, seeking a ventilation consultant for their Everett Laboratory (EVL). The project aims to comprehensively evaluate and optimize the laboratory's ventilation systems, with work estimated to begin at the end of Q3 and deliverables to be submitted by the end of Q4. The scope of work includes assessing current ventilation system design and performance, evaluating exposure risks to airborne hazards, determining appropriate airflow requirements, identifying performance enhancement opportunities, and providing strategies for system optimization and change management.

The Statement of Work does not include specific pricing details, funding sources, or contract award information. However, the project focuses on creating a comprehensive framework for improving laboratory ventilation systems, with an emphasis on risk mitigation, efficiency enhancement, and establishing effective change management protocols. The consultant will be expected to provide actionable recommendations that can be implemented to improve the overall ventilation system performance at the Everett Laboratory, addressing potential hazards and optimizing airflow requirements for laboratory spaces and exposure control devices.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date:

Exhibit A Ventilation Consultant Statement of Work

1.0 INTRODUCTION/BACKGROUND

TerraPower is a nuclear innovation company that conducts a variety of work with various levels of hazards which has driven a demand for an assessment of our current ventilation systems operations.

2.0 PURPOSE

This Statement of Work outlines the deliverables required in Section 3 at Everett Laboratory (EVL). Work is estimated to begin at the end of Q3 and deliverables submitted by the end of Q4.

3.0 SCOPE OF WORK

· Evaluate the lab ventilation system(s) current design and performance

· Assess the risk of exposure to potentially hazardous airborne hazards

· Determine appropriate airflow requirements for lab spaces and exposure control devices

· Identify opportunities to enhance ventilation system performance and efficiency

· Provide strategies and paths for an optimization project

· Provide a framework to establish an effective change management program

· Provide actionable recommendations for an optimization project 15800 Northup Way, Bellevue, WA 98008 www.TerraPower.com P. +1 (425) 324-2888 F. +1 (425) 324-2889

15800 Northup Way, Bellevue, WA 98008 www.TerraPower.com P. +1 (425) 324-2888 F. +1 (425) 324-2889 image1.png image2.png

File details come from the government source that posted it. Updated .