3-Pavement Sensor Detail.pdf
PDF 920 KB Posted
- Solicitation number
- IFS AVI B2600008
- Issued by
- Dallas County, Texas
About this file
The documents are electrical and lighting design sheets for the Runway 13R-31L Reconstruction project at Dallas Love Field, prepared by HNTB. The project involves detailed specifications for installing pavement surface sensors, remote power units, lighting coordinates, junction cans, light bases, and associated electrical infrastructure. The design sheets provide comprehensive technical details for sensor placement, grounding, cable routing, and installation methods across multiple electrical system components.
The electrical details include specific requirements for sensor systems, such as passive and subsurface pavement sensors, temperature probes, air temperature/relative humidity sensors, and cellular routing equipment. The documents specify precise installation techniques, including saw cut methods for sensor placement, cable routing, and grounding procedures. The technical specifications indicate a comprehensive approach to runway electrical infrastructure renovation, with meticulous attention to sensor placement, power distribution, and system integration. The project appears to be funded through municipal or airport infrastructure improvement channels, with a focus on modernizing runway electrical and sensing systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 5-BDPS-FRM-113GeneralConditionsforInformalSolicitations(IFS)-0127121.docx | DOCX document | |
| 1-02 - 2.4.21 - Standard Forms with Insurance.pdf | ||
| 4-Scope of Work.docx | DOCX document | |
| 2-Insurance Requirements-RR-250910-AVI-17417-Runway Weather Sensor Tracking.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. A MINIMUM OF THREE LEVELS OF REVIEW WERE PERFORMED ON THE TABULATED
COORDINATES. HOWEVER, IF DURING LAYOUT, THE CONTRACTOR OR INSPECTOR
NOTICES ANY ABERRATION, PLEASE CONTACT THE ENGINEER IMMEDIATELY TO CHECK
THAT PARTICULAR LOCATION AGAIN.
2. COORDINATES IDENTIFY THE GEOMETRIC CENTER OF THE LIGHT BASE, JUNCTION CAN,
JUNCTION CAN PLAZA, OR MANHOLE/PULLBOX.
3. FURNISH AND INSTALL TWO-PIECE L-868B FULL DEPTH LIGHT BASE IN NEW RIGID
PAVEMENT. SEE SHEET ED01.
4. FURNISH AND INSTALL L-868B ONE-PIECE BASE, 12" DEEP, WITH 1-3/8" FLANGE RING,
3/4" MULTIHOLE ADAPTER RING, AND ANTI-ROTATION HOOKS IN EXISTING PAVEMENT.
SEE SHEET ED06.
5. FURNISH AND INSTALL L-867B ADJUSTABLE LIGHT BASE IN NEW CONCRETE PAVEMENT
SHOULDER. SEE SHEET ED03.
6. FURNISH AND INSTALL TWO-PIECE L-868B FULL DEPTH LIGHT BASE IN NEW CONCRETE
PAVEMENT SHOULDER. SEE SHEET ED02.
7. FURNISH AND INSTALL L-867D JUNCTION CAN IN EARTH. SEE SHEET ED07.
8. FURNISH AND INSTALL L-867D JUNCTION CAN IN NEW CONCRETE PAVEMENT
SHOULDER. SEE SHEET ED07.
9. FURNISH AND INSTALL FIXTURE AND ISOLATION TRANSFORMER ON EXISTING LIGHT
BASE INDICATED.
10. DRAIN LIGHT BASE INDICATED TO STORM STRUCTURE. MAINTAIN MINIMUM 1% SLOPE
TO DRAIN STRUCTURE. GROUT CONDUIT PENETRATION TO FORM WATERTIGHT SEAL.
NO SEPARATE PAYMENT SHALL BE MADE.
11. FURNISH FIXTURE AND TRANSFORMER TO OWNER FOR INSTALLATION BY OTHERS.
COORDINATE SHEET NOTES:
LIGHTING CURVE RADII DATA
E
D
C
B
A
NO.
F
SHEET NO.
CHORD LENGTH
APPROXIMATE
RADIUS
LIGHTS
NO. OF
LENGTH
ARC
COORDINATES
MANHOLE/PULLBOX SCHEDULE
NUMBER
PSS-1
NUMBER
INDEX
NORTHING EASTING
SEE NOTE 3
NOTE
SEE NOTE 3
PSS-2/SP-1 SEE NOTE 3
PSS-3
JCP-1 6-CAN PLAZA
JUNCTION CAN PLAZA
145.30' 792.5° 24.15'
JCP-2
JCP-3
JCP-4
JCP-5
JCP-6
JCP-7
JCP-8
JCP-9
JCP-10
JCP-11
COORDINATES
MANHOLE/PULLBOX SCHEDULE
NUMBER
NUMBER
INDEX
NORTHING EASTING NOTE
JC-1 SEE NOTE 8
JUNCTION CAN
JC-2
JC-3
JC-4
JC-5
JC-6
JC-7
JC-8
JC-9
JC-10
JC-11
6997759.51 2471506.69
6997590.61 2471677.20
6997408.33 2471861.20
6997218.32 2472053.02
6996977.22 2472296.42
6996736.11 2472539.82
6996485.12 2472793.20
6996295.10 2472985.02
6995988.16 2473309.10
6995690.97 2473594.90
6995393.84 2473894.85
6995203.83 2474086.67
6994871.31 2474422.36
6994538.79 2474758.05
6994348.77 2474949.87
6994070.81 2475230.51
6993683.73 2475621.24
6993493.71 2475813.06
6993248.81 2476060.29
6993003.90 2476307.53
6992747.74 2476566.13
6992557.72 2476757.95
6992309.30 2477008.74
6992477.90 2477175.93
6992071.08 2477249.22
6991834.27 2477488.29
6991661.01 2477677.41
6991471.67 2477854.33
6997402.34 2471117.70
6997118.52 2471020.26
JCP-12
JCP-13
JCP-14
JCP-15
JCP-16
JCP-17
JCP-18
JCP-19
JCP-20
JCP-21
JCP-22
JCP-23
JCP-24
JCP-25
JCP-26
JCP-27
JCP-28
JCP-29
JCP-30
JCP-31
JCP-32
JCP-33
JCP-34 6996084.34 2472426.92
6995909.55 2472603.37
6995931.92 2472259.30
6994146.33 2474383.37
6992951.43 2475850.31
6992599.55 2476205.54
6992247.52 2476560.92
6992061.18 2476749.03
6996056.86 2472639.74
6994674.58 2474035.17
6993970.83 2474745.61
6993267.08 2475456.06
6992563.33 2476166.50
6993708.36 2474443.05
JC-12
JC-13
JC-14
JC-15
JC-16
JC-17
JC-18
JC-19
JC-20
JC-21
6996307.19 2472462.53
6996034.01 2472738.42
6995768.17 2473006.78
6995416.29 2473362.01
6995064.42 2473717.23
6994712.54 2474072.45
6994353.38 2474435.03
6994007.06 2474784.65
6993655.18 2475139.87
6993303.31 2475495.09
6996573.71 2472193.58
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
6-CAN PLAZA
6-CAN PLAZA, 10
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
2-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
6-CAN PLAZA
PAVEMENT SURFACE SENSOR
JC-22
JC-23
JC-24 6993405.65 2474748.64
6995103.19 2474188.28
EL04
EL04
EL05
EL08
EL08
6995378.33 2473324.72
6996349.60 2472060.02
6996628.06 2472240.37
6994404.20 2474485.38
6992109.97 2476801.44
6994239.41 2475397.70
6-CAN PLAZA6993172.51 2476474.72
PB-1 AIRCRAFT RATED
PULLBOXES
PB-2
PB-3
PB-4
PB-5
PB-6
PB-7
6997808.02 2471498.44
6997501.04 2471808.60
6997168.00 2472144.81
6996883.91 2472444.97
6996586.45 2472731.89
6996234.63 2473087.16
6995987.03 2473337.09
AIRCRAFT RATED, 10
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED, 10
AIRCRAFT RATED
AIRCRAFT RATED
JCX-1
JUNCTION CAN - LIGHTED X
JCX-2
JCX-3
JCX-4
JCX-5
6997478.24 2471280.86
6991378.17 2477708.93
6991324.11 2478062.76
6991270.05 2478416.59
6997117.07 2471028.19 SEE NOTE 7
MH-1
MANHOLES
MH-2
6995030.34 2474310.81
6994603.77 2473888.53
PB-8
PB-9
PB-10
PB-11
6995742.79 2473583.62
6995495.18 2473833.54
6995143.36 2474188.81
6997412.90 2471107.04
6997121.55 2471003.70
6995564.50 2472918.67
6995244.50 2473241.71
6994914.69 2473574.66
6994389.92 2474104.42
6993936.38 2474562.27
6991246.69 2477550.39
6990912.39 2477887.84
PB-12
PB-13
PB-14
PB-15
PB-16
PB-17
PB-18
PB-19
PB-20
PB-21
6995887.30 2472603.19
6994161.77 2474344.29
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
AIRCRAFT RATED
6993963.36 2474568.08
6993996.21 2474234.66 6-CAN PLAZA, 10
JCP-35
JCP-36
JCP-37
JCP-38
JCP-39
6-CAN PLAZA
SEE NOTE 8
SEE NOTE 8
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
SEE NOTE 7
AIRCRAFT RATED, 10
AIRCRAFT RATED
FIXTURE COLOR LEGEND
B = BLUE
C = CLEAR
O = OBSCURE
Y = YELLOW
R = RED
G = GREEN
215.56' 10247.5° 23.94'
175.98' 977.5° 21.92'
57.18' 340.0° 28.48'
53.25' 350.0° 26.31'
70.44' 370.0° 34.85'
G EL08 97.59' 470.0° 32.24'
H EL11 149.23' 590.0° 37.07'
K EL14 98.17' 562.50° 24.39'
L EL14 149.23' 595.0° 37.07'
EL01, EL02,
EL04 THRU EL08
J EL11 90.32' 590.0° 22.44'
6-CAN PLAZA, 10
6-CAN PLAZA, 10
8-CAN PLAZA, 10
6-CAN PLAZA, 10
6-CAN PLAZA, 10
6-CAN PLAZA, 10
6-CAN PLAZA, 10
6-CAN PLAZA, 10
JC-25 6991559.05 2478226.41 SEE NOTE 7
AIRCRAFT RATED, 10
AIRCRAFT RATED, 10
AIRCRAFT RATED, 10
PULLBOXES
6994453.74 2473761.13PB-22 AIRCRAFT RATED, 10
6994101.87 2474116.36PB-23 AIRCRAFT RATED
6993749.99 2474471.58 PB-24 AIRCRAFT RATED
6993398.12 2474826.80 PB-25 AIRCRAFT RATED
6993301.45 2474731.05 PB-26 AIRCRAFT RATED
6996263.54 2473081.86PB-27 AIRCRAFT RATED
21A
6990578.08 2478225.30 PB-21A AIRCRAFT RATED
RUNWAY 13R-31L RECONSTRUCTION
RevisionNo.
File Name:
Date: December 11, 2020
SHEET
Approved
Checked
Drawn
MBSDesign
DSF
SME
MBS
P l o t t e d
D e c e m b e r
T i m e
P
M
B y
D a v i d
F l o r e s
J o b
N o
D
S
Date By App'd.
FIELD BULLETIN #2
Chkd.
Consulting Engineers
817-498-0388
COLLEYVILLE, TEXAS
P. O. BOX 799
M. B. SZABO
82776
13R31L-EL-ED17_24.DWG
LIGHTING
COORDINATES ED24
FIELD BULLETIN #2
12/11/2020 DSF MBSAJP
E = SEE EQUIPMENT NOTE (EN-#)
SS# = SAFETY SWITCH (TYP)
C = NEW OR EXISTING
N = NEW DEVICE(S) TO BE FURNISHED & INSTALLED
(~XXXX') = APPROXIMATELY XXXX FEET
D
A B
D = SEE SHEET NOTE (SN-#)
E
B = FUSED @, RATED KVA, ETC.
LEGEND
A = IDENTIFICATION
C
= JUNCTION CAN
1. INSTALL DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. USE GREY SURFACE SENSORS IN CONCRETE
PAVEMENT.
2. CONTRACTOR SHALL FURNISH AND INSTALL SUBSURFACE SENSOR PROBE ADJACENT PASSIVE SURFACE SENSOR PER
MANUFACTURER'S INSTALLATION MANUAL. SEE SHEET ED28 FOR ADDITIONAL INFORMATION.
3. CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED DEVICES PROVIDING A COMPLETE AND OPERATIONAL SYSTEM.
4. CONTRACTOR SHALL FURNISH AND INSTALL ANTENNA AND CELLULAR MODEM DEVICE AS REQUIRED TO FACILITATE REMOTE
WEB HOSTING BY THE MANUFACTURER.
5. CONTRACTOR SHALL ESTABLISH 480VAC SINGLE PHASE POWER TO SS3 BY TAPPING THE PRIMARY SIDE OF THE EXISTING
480/277VAC DISCONNECT SWITCH (2 PHASES AND GROUND).
6. CONTRACTOR SHALL MOUNT THE RPU MAIN DISCONNECT ON THE EXISTING GATE POWER PEDESTAL ADJACENT THE
EXISTING MAIN DISCONNECT SWITCH FOR THE GATE POWER PANEL.
SHEET NOTES (SN-#):
1. HEAVY DUTY NEMA 3R, 240V, 30A, 2W, SOLID NEUTRAL, SAFETY SWITCH FUSED AS INDICATED. SQUARE D CAT. NO. H221NRB
OR APPROVED EQUIVALENT.
2. AC POWER LIGHTNING AND SURGE ARRESTOR RATED AT 120/240V (RMS), 3W, 1Ø, 45KA. LIGHTNING PROTECTION CORP.
MODEL LPC-11765U-13E OR APPROVED EQUIVALENT.
3. INSTALL RPU DEVICES AND SENSORS PER MANUFACTURER'S INSTRUCTIONS. SEE SHEET ED26 ADDITIONAL INFORMATION.
4. FURNISH AND INSTALL A DUAL L-810 LED OBSTRUCTION LIGHT (DIALIGHT #860-1R01-002, OR APPROVED EQUIVALENT).
5. ENCAPSULATED TRANSFORMER, 3 KVA, 480:120/240 VAC, 1Ø, COPPER LEAD WIRE TERMINATIONS, NEMA 3R. SOLA HD
HS5F3AS OR APPROVED EQUIVALENT.
6. HEAVY DUTY NEMA 3R, 600V, 30A, 2W, SAFETY SWITCH FUSED AS INDICATED. SQUARE D CAT. NO. H361RB OR APPROVED
EQUIVALENT.
EQUIPMENT NOTES (EN-#):
1. MANUFACTURER'S TYPE IIA SENSOR CABLE MOLDED INTO SURFACE SENSORS (PSS AND SP). STANDARD LENGTH IS 150'.
SEE MANUFACTURER'S SENSOR CABLES SPLICING INSTRUCTION MANUAL. SPLICES SHALL BE MADE INSIDE JUNCTION CANS.
2. MANUFACTURER'S TYPE V SENSOR EXTENSION CABLE(S). SPLICE TO SENSOR CABLE IN JUNCTION CANS LOCATED IN
RUNWAY SHOULDER PAVEMENT ADJACENT SENSOR LOCATION. SEE MANUFACTURER'S SENSOR CABLES SPLICING
INSTRUCTION MANUAL.
3. 2-1/C #12 AWG 600V THWN AND 1-1/C #12 GROUNDING CONDUCTOR IN 3/4" LIQUID-TIGHT METALLIC CONDUIT. OBSTRUCTION
LIGHT SHALL BE WIRED PARALLEL WITH RPU POWER.
4. 2-1/C #10 AWG AND 1-1/C #10 GROUNDING CONDUCTOR IN 1"LIQUID-TIGHT METALLIC CONDUIT.
5. 2-1/C #8 AWG 600V THWN AND 1-1/C #8 GROUNDING CONDUCTOR IN 1"LIQUID-TIGHT METALLIC CONDUIT.
6. 2-1/C #8 AWG 600V THWN AND 1-1/C #8 GROUNDING CONDUCTOR IN 2" CONDUIT (MEASURED AND PAID FOR SEPARATELY).
7. 2-1/C #10 AWG 600V THWN AND 1-1/C #10 GROUNDING CONDUCTOR IN 1" GRSC.
WIRE NOTES (WN-#):
RPU = REMOTE PROCESSING UNIT
SP-1 = SUBSURFACE PROBE 1
N
SN-1
BLOCK
DESCRIPTION
PSS-# = PAVEMENT SURFACE SENSOR #
PSS-1
PAVEMENT
NO. 1
SURFACE SENSOR
SAFETY SWITCH
SS3 N
(HEAVY DUTY)
20A N
LIGHTNING
PROTECTION
SPD
RPU - R/W 13R-31L
N
PAVEMENT
NO. 2
SURFACE SENSOR
SN-1
NPSS-3
PAVEMENT
NO. 3
SURFACE SENSOR
SN-1
PSS-2
NA N N
ANTENNA REMOTE
PROCESSING UNIT
OBSTRUCTION
LIGHT
RPU OBS
SN-4
WN-3
480VAC, WN-5
N
SN-2
SP-1
SUBSURFACE
PAVEMENT SENSOR
= L-868B BLANK LIGHT BASE
JC-1
(~3,200')
JC-8
JC-15
(~3,300')
WN-1
WN-2
WN-1
WN-2
WN-1
WN-1
WN-1 WN-1
PSS-3
PPS-1
WN-1
PSS-2 / SP-1
(~470')
WN-2
(4 TYP)
WN-3
PAVEMENT SURFACE SENSOR BLOCK DIAGRAM
NTS
N
STEPDOWN XFMR
480:120/240 VAC
T1
3 KVA
SAFETY SWITCH
NO. 2
SS2
EN-6
N
(HEAVY DUTY)
10A
120VAC, WN-4
SAFETY SWITCH
NO. 1
SS1 N
(HEAVY DUTY)
10A
480VAC, WN-7
(~1,000')
100A SAFETY SWITCH
ESS E
EXISTING
480/277VAC
EXISTING GATE
POWER PEDESTAL
480VAC, WN-6
SN-5EN-6
EN-5 EN-1 EN-2
EN-3 EN-4
100A
T1 = STEPDOWN TRANSFORMER
SN-6
NO. 3
RUNWAY 13R-31L RECONSTRUCTION
RevisionNo.
File Name:
Date: APRIL 24, 2020
SHEET
Approved
Checked
Drawn
MBSDesign
DSF
SME
MBS
P l o t t e d
A p r i l
T i m e
A
M
B y
D a v o r e s
J o b
N o
D
S
Date By App'd.
IFC SUBMITTAL
Chkd.
Consulting Engineers
817-498-0388
COLLEYVILLE, TEXAS
P. O. BOX 799
M. B. SZABO
82776
13R31L-EL-ED25.DWG
ELECTRICAL
DETAILS ED25
SHEET NOTES (SN-#):
6"
TYP
2'-6"
SIDE ELEVATION
FRONT ELEVATION
#6 COUNTERPOISE
ABOVE FINISHED SLAB (TYP)
2" GRSC WITH COUPLINGS
EXTENDING 1/4" MAX
FRANGIBLE COUPLINGS
STRUCTURE WITH
ALUMINUM RPU SUPPORT
WITH COUPLING EXTENDING 1/4" MAX
2" SCH 40 PVC (TYP)
2" GRSC NIPPLE IN CONCRETE (TYP)
ABOVE FINISHED SLAB
OBSTRUCTION LIGHT (TYP)
DUAL FAA L-810 LED
2" SCH 40 PVC (TYP) TO PAVEMENT SENSORS
REAR ELEVATION
1/2" LIQUID-TIGHT FLEXIBLE
METALLIC CONDUIT
1/2" LIQUID-TIGHT FLEXIBLE METALLIC
CONDUIT TO 120/240 VAC SAFETY
SWITCH FOR OBSTRUCTION LIGHT
POWER
RPU
480:120VAC STEPDOWN
TRANSFORMER
SS
RPU
RPU
XFMR
1. AIRPORT PAVEMENT SURFACE SENSOR SYSTEM SHALL INCLUDE THE
TABULATED ITEMS SHOWN ON SHEET ED27 OR APPROVED EQUIVALENTS.
2. CONTRACTOR SHALL INSTALL SURFACE CONDITION SENSORS AND SUB
SURFACE SENSORS CONNECT TO SENSOR EXTENSION CABLES FROM
THE RPU. CABLE SPLICES SHALL ONLY BE MADE IN JUNCTION CANS OR
PULLBOXES AND SHALL BE MINIMIZED.
3. CONTRACTOR SHALL FURNISH AND INSTALL RPU ASSEMBLY AS
SPECIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS
COMPLETE WITH ALL SENSORS, BATTERY BACKUP, CELLULAR MODEM
AND ANTENNA AS REQUIRED FOR WEB HOSTING.
4. SEE SHEET ED25 FOR SURFACE SENSOR BLOCK AND CABLE DIAGRAM.
5. FURNISH AND INSTALL ADDITIONAL CONDUITS, SAFETY SWITCHES,
TRANSFORMERS, AND SUPPORT STRUCTURES AS INDICATED. SEE SHEET
ED25 FOR WIRING DIAGRAMS. RPU REQUIRES STEPDOWN
TRANSFORMER TO ADDRESS VOLTAGE DROP.
6. CONDUIT CONFIGURATIONS AND ORIENTATIONS SHOWN ON THIS SHEET
ARE FOR REFERENCE ONLY. CONTRACTOR SHALL COORDINATE CONDUIT
ORIENTATION WITH LAYOUT SHEETS AND CONFIGURATIONS/SIZES WITH
EQUIPMENT AND WIRING REQUIREMENTS.
1" LIQUID-TIGHT FLEXIBLE METALLIC
CONDUIT FROM 120/240 VAC SAFETY
SWITCH (TYP)
1" LIQUID-TIGHT FLEXIBLE
METALLIC CONDUIT AS
REQUIRED
REMOTE POWER UNIT
WINDSPEED/DIRECTION
SENSOR
FRANGIBLE COUPLING (TYP)
NOTES:
10'
3'
RPU SUPPORT STRUCTURE
RPU GROUNDING DETAIL
7/16" DIA, 32 STRANDS OF 17
AWG BASKET WEAVE TINNED
BARE COPPER RPU GROUND
CABLE (TYP)
3/4" SCH 40 PVC
(TYP) FOR RPU
GROUNDING
RELATIVE HUMIDITY/AIR
TEMPERATURE SENSOR
2" EMT WITH FRANGIBLE
COUPLINGS AS
REQUIRED (TYP)
#4 @ 10.5" NOMINAL BOTH WAYS
STAINLESS STEEL UNISTRUT AS
REQUIRED OR APPROVED
EQUIVALENT
SS
PRI
SS
SEC
XFMR
2" SCH 40 PVC FOR 480
VAC POWER SERVICE,
SEE SN-5
2" EMT WITH FRANGIBLE COUPLINGS AS
REQUIRED FOR SENSOR CABLES
3/4" CHAMFER (TYP)
M
A X
1. CONTRACTOR SHALL PROVIDE AND INSTALL RPU GROUNDING AS
SHOWN AS PART OF PAVEMENT SURFACE CONDITION SENSOR
SYSTEM BID ITEM.
2. GROUND ROD CONNECTIONS SHALL BE EXOTHERMIC WELDED
CADWELD OR APPROVED EQUIVALENT.
2" T WITH SIDE REDUCER FOR 1/2" FLEX
CONDUIT
SEE LAYOUT DRAWINGS
FOR LOCATION INFORMATION
WIVIS/OWI PROCESSOR ENCLOSURE
PWD22 PRECIPITATION/
VISIBILITY SENSOR
4000 PSI
CONCRETE
P-610
5'-0"
SEE RPU GROUNDING
DETAIL (TYP)
4000 PSI
CONCRETE P-610
4000 PSI
CONCRETE P-610
4000 PSI
CONCRETE
P-610
5/8" X 8'
GROUND ROD
#6 BSDC
1" SCH 80 PVC FOR XFMR GROUND
3/4" X 10' GROUND
ROD (TYP)
MECHANICAL GROUND LUG ON
SUPPORT STRUCTURE AND
RPU ENCLOSURE (TYP)
40"
30"
RUNWAY 13R-31L RECONSTRUCTION
RevisionNo.
File Name:
Date: APRIL 24, 2020
SHEET
Approved
Checked
Drawn
MBSDesign
DSF
SME
MBS
P l o t t e d
A p r i l
T i m e
A
M
B y
D a v o r e s
J o b
N o
D
S
Date By App'd.
IFC SUBMITTAL
Chkd.
Consulting Engineers
817-498-0388
COLLEYVILLE, TEXAS
P. O. BOX 799
M. B. SZABO
82776
13R31L-EL-ED26.DWG
DETAILS ED26
TRANSVERSE
JOINT (TYP)
M I N
NOTES:
3'-6" TYP
SURFACE CONDITION SENSOR PLACEMENT
RUNWAY SURFACE CONDITION SENSOR INSTALLATION
18.75' (TYP)
LONGITUDINAL
JOINT (TYP)
2" SCH 40 PVC
SEE NOTE 1
TO RPU SEE LIGHTING &
SIGNAGE LAYOUT SHEETS
L-868 LIGHT BASE WITH
BLANK LID SEE DETAIL ED01
PAVEMENT SURFACE SENSOR
(2"x4.7"x3.5" DEEP), VERIFY
INSTALLATION WITH
MANUFACTURER
23.75''
SENSOR CABLE IN SAW
KERF SEE NOTE 2
L-868 EXTENSION, 12" DIA,
DEPTH FIELD DETERMINED,
1 3/8" BAND RING AND
24 3/8-16 THREADED HOLES
VEGA #A2419MEM OR
EQUIVALENT. SEE NOTE 2
L-868 BASE, 12" DIA, 18"
DEEP BOTTOM SECTION
WITH 2" THREADED HUBS
SEE NOTE 3
#6 COUNTERPOISE
1. SEE SHEET ED01 FOR L-868 LIGHT BASE INSTALLATION DETAILS IN NEW RIGID PAVEMENT.
2. AFTER CORING FOR L-868 EXTENSION (TOP CAN SECTION) AND PRIOR TO ITS INSTALLATION, CORE AND SAW CUT AS REQUIRED TO INSTALL THE PAVEMENT SURFACE SENSOR. VERIFY
INSTALLATION OF SENSOR WITH MANUFACTURER.
3. INTERNAL AND EXTERNAL MECHANICAL GROUND LUGS SHALL BE PROVIDED.
NOTE:
18.75' (TYP)
L-868B 3/4" BLANK LID
1. ORIENTATION MAY VARY. SEE LAYOUT PLAN SHEETS FOR CONFIGURATION.
5/8" X 8'
GROUND
ROD
TABLE NOTES:
1. RWS200 SHALL INCLUDE THE BASE STRUCTURE, BACK PLATE, MOUNTING FRAME,
INTERFACE FOR THREE (3) SURFACE SENSORS AND ONE (1) SUBSURFACE PROBE, BACK
PLATE, MAINS POWER WITH US SOCKET AND 26AH BATTERY BACKUP.
2. ALL SPECIFIED EQUIPMENT LISTED ABOVE SHALL INCLUDE ALL NECESSARY CABLES,
MOUNTING KITS AND ASSOCIATED HARDWARE, CELLULAR DEVICES, SIM CARD, AND
INTERFACE HARDWARE AS REQUIRED TO FORM A COMPLETE AND OPERATIONAL WEB
HOSTED SYSTEM.
3. SEE SPECIFICATION L-120-2.2 FOR SYSTEM SERVICE AGREEMENT REQUIREMENTS.
T
Y P
PAVEMENT SURFACE SENSOR
(2"x4.7"x3.5" DEEP), VERIFY
INSTALLATION WITH
MANUFACTURER
4.75"
GROMMET FOR
SENSOR CABLE(S)
TO ENTER CAN
RUNWAY 13R-31L RECONSTRUCTION
RevisionNo.
File Name:
Date: APRIL 24, 2020
SHEET
Approved
Checked
Drawn
MBSDesign
DSF
SME
MBS
P l o t t e d
A p r i l
T i m e
A
M
B y
D a v o r e s
J o b
N o
D
S
Date By App'd.
IFC SUBMITTAL
Chkd.
Consulting Engineers
817-498-0388
COLLEYVILLE, TEXAS
P. O. BOX 799
M. B. SZABO
82776
13R31L-EL-ED27.DWG
DETAILS ED27
1 2
12"
TEMPERATURE PROBE HOLE.
SEE NOTE 4, DRILL HOLE
0.6" DIA. 12" DEEP
(MEASURED FROM SURFACE)
SAW KERF TO L-868
BLANK LIGHT BASE
FOR SENSOR CABLE(S)
1/2" WIDE, 3.5" DEEP
SAWCUT AND REMOVE PAVEMENT TO
A DEPTH OF 3.5" FOR PAVEMENT
SURFACE SENSOR (2"x4.7"x3.5" DEEP), VERIFY INSTALLATION WITH
MANUFACTURER
NORMAL OVERCUT
OF SAW BLADE (TYP)
1 2
SENSOR
CABLE/CONNECTOR KERF
SAW KERF TO EDGE OF PAVEMENT
FOR SENSOR CABLES
1/2" WIDE, 3.5" DEEP
TEMPERATURE
PROBE HOLE
TOP VIEW
SIDE VIEW
1. CUT SAW KERF USING A SINGLE 1/2" WIDE BLADE OR TWO
(2) 3/16" BLADES.
2. CLEAN AND DRY SAW CUT HOLE AND SAW KERF WITH DRY
COMPRESSED AIR PRIOR TO PERFORMING ANY SENSOR
INSTALLATION.
3. SAW CUT HOLE FOR PAVEMENT SENSOR (2"x4.7"x3.5" DEEP)
VERIFY INSTALLATION METHOD WITH MANUFACTURER.
4. SUBSURFACE TEMPERATURE PROBE IS ONLY INSTALLED
AT ONE LOCATION.
TOP VIEW
SIDE VIEW
HOLE FOR TEMPERATURE
PROBE. SN-4
SENSOR CABLE TYPE IIA
FILL WITH ENCAPSULATING
COMPOUND, TOP WITH
TOPCOAT COMPOUND PER
MANUFACTURERS
INSTRUCTIONS
PAVEMENT SURFACE SENSOR; TOP OF
SENSOR HAS ROUGH TEXTURE FINISH
(SOME MODELS HAVE A DIMPLE OR
DEPRESSION IN TOP OF SENSOR HEAD)
VERIFY INSTALLATION METHOD WITH
MANUFACTURER
FILL CAVITY WITH ENCAPSULATING
COMPOUND 1/8" FROM TOP OF
PAVEMENT AND SENSOR.
PAVEMENT SENSOR HEAD; INSTALL
TOP OF SENSOR FLUSH WITH
PAVEMENT SURFACE
FILL TOP OF SAW KERF ABOVE
BACKER ROD WITH APPROVED,
FLEXIBLE SEALANT
5/8" BACKROD; INSTALL
TWO ABOVE SENSOR
CABLES
5/8" BACKROD; INSTALL
ONE BELOW SENSOR
CABLES
SENSOR CABLE TYPE IIA
FILL CAVITY WITH ENCAPSULATING
COMPOUND FROM 20 OZ. TUBE TO
BOTTOM OF SAW KERF
TEMPERATURE PROBE;
INSTALL IN BOTTOM OF
HOLE. SN-4
SN-4
SHEET NOTES (SN-#):
INFORMATION ON THIS SHEET IS PROVIDED
TO ASSIST WITH BIDDING PROJECT.
CONTRACTOR SHALL FOLLOW MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
TYPICAL PAVEMENT SENSOR AND
TEMPERATURE PROBE SAW CUT AND KERF DETAIL
TYPICAL PAVEMENT SENSOR AND
TEMPERATURE PROBE INSTALLATION DETAIL
CUT RECTANGULAR CAVITY FOR
PAVEMENT SURFACE SENSOR
(2"x4.7"x3.5" DEEP), VERIFY
INSTALLATION WITH
MANUFACTURER
NORMAL OVERCUT
OF SAW BLADE (TYP)
PUDDY UNDER SENSOR TO SET
LEVEL AS REQUIRED
NORMAL OVERCUT
OF SAW BLADE (TYP)
NORMAL OVERCUT
OF SAW BLADE (TYP)
RUNWAY 13R-31L RECONSTRUCTION
RevisionNo.
File Name:
Date: APRIL 24, 2020
SHEET
Approved
Checked
Drawn
MBSDesign
DSF
SME
MBS
P l o t t e d
A p r i l
T i m e
A
M
B y
D a v o r e s
J o b
N o
D
S
Date By App'd.
IFC SUBMITTAL
Chkd.
Consulting Engineers
817-498-0388
COLLEYVILLE, TEXAS
P. O. BOX 799
M. B. SZABO
82776
13R31L-EL-ED28.DWG
DETAILS ED28