This document is a drawing specification for Vacuum Insulated Panels (VIPs) to be used in the Mobile Integrated Remains Collection System (MIRCS) at Letterkenny Army Depot (LEAD).

The drawing provides detailed dimensional requirements for 13 different VIP part numbers, including length, width, and thickness tolerances. Key performance requirements are specified, such as a maximum thermal conductivity of 0.020 BTU-inch/ft2-hr-F and no more than 2.8% degradation per year. The VIPs must be rated for a minimum temperature exposure of 200 degrees Fahrenheit.

The related federal contract opportunity is a requirements supply contract with a base period plus two option periods for VIPs in support of the Force Provider Program at LEAD. The solicitation number is W911N2240056, issued by the Department of the Army Materiel Command Contracting Command Redstone Arsenal.

View the file

Other files

File Type Posted
2_Purchase Description (copy).docx DOCX document
1_Solicitation Notes W911N224Q0056.docx DOCX document
SOLICITATION W911N224Q0056.pdf PDF
4_Safety Review - Vacuum Insulated Panels.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

A

B

C

D

LEAD-FP-5131 A

REVDRAWING NO.

C

SIZE

0NDM7

DAI

MIRCS VACUUM INSULATED PANELS

SHEETSCALE N/A WEIGHT N/A

TITLE

CHAMBERSBURG, PA 17201

LETTERKENNY ARMY DEPOT

APPLICATION

USED ONNEXT ASSY

MATERIAL

UNLESS OTHERWISE SPECIFIED,

DIMENSIONS ARE IN INCHES:

TOLERANCES ARE:

DO NOT SCALE DRAWING

DECIMALS

.X±.06

.XX±.03

ANGLE

±1°

.XXX±.015

FRACTIONS

±1/32

REVISION HISTORY

ZONE REV DESCRIPTION DATE APPROVED

- INITIAL PRODUCTION RELEASE - -

A ADDED DASH NUMBERS FOR ALL PANELS 07 JUL 23 MJD

MIRCS

VIP

OF 11DATE

LEAD APRVD

CHECKED

DRAWN

07 JUL 23

NOT REQUIRED

MJ DESTEFANO

THIRD ANGLE

PRODUCTION ENGINEERING

DIVISION

SAFETY

PROJECTION

DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE. DISTRIBUTION IS UNLIMITED.

MJ DESTEFANO

SP DULEY

NOTES:

1. INTERPRET DRAWING IN ACCORDANCE WITH ASME Y14.100-2013 AND ASME Y14.5-2009.

2. THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.020 BTU-INCH/FT2-HR-F PER ASTM C518.

3. PANEL PREFORMANCE DEGRADATION SHALL NOT EXCEED 2.8% PER YEAR.

4. VIP SHALL BE RATED FOR TEMPATURE EXPOSURE OF 200 DEGREES F MINIMUM.

PANEL SIZE TABLE

PART NUMBER A (LENGTH) B (WIDTH) C (THICKNESS)

LEAD-FP-5131-A 23 5/8 35 1/8 0.75

LEAD-FP-5131-B 21 3/8 35 1/8 0.75

LEAD-FP-5131-C 26 3/8 22 5/8 0.75

LEAD-FP-5131-D 8 7/8 12 0.63

LEAD-FP-5131-E 8 7/8 29 1/2 0.63

LEAD-FP-5131-F 17 1/4 24 1/2 0.63

LEAD-FP-5131-G 26 28 3/8 0.63

LEAD-FP-5131-H 21 1/2 21 1/2 0.75

LEAD-FP-5131-J 21 1/2 45 1/2 0.75

LEAD-FP-5131-K 13 5/8 12 3/4 0.75

LEAD-FP-5131-L 14 28 0.63

LEAD-FP-5131-M 14 13 0.63

LEAD-FP-5131-N 24 1/2 29 1/2 0.75

LEAD-FP-5131-P 19 1/8 27 1/2 0.63

LEAD-FP-5131-Q 19 1/8 39 3/8 0.50

A (LEGNTH) +/- 0.125

B (WIDTH) +/- 0.125 C (THICKNESS) +/- 0.062