This document is a drawing specification for Vacuum Insulated Panels (VIPs) to be used in the Mobile Integrated Remains Collection System (MIRCS) at Letterkenny Army Depot (LEAD).
The drawing provides detailed dimensional requirements for 13 different VIP part numbers, including length, width, and thickness tolerances. Key performance requirements are specified, such as a maximum thermal conductivity of 0.020 BTU-inch/ft2-hr-F and no more than 2.8% degradation per year. The VIPs must be rated for a minimum temperature exposure of 200 degrees Fahrenheit.
The related federal contract opportunity is a requirements supply contract with a base period plus two option periods for VIPs in support of the Force Provider Program at LEAD. The solicitation number is W911N2240056, issued by the Department of the Army Materiel Command Contracting Command Redstone Arsenal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2_Purchase Description (copy).docx | DOCX document | |
| 1_Solicitation Notes W911N224Q0056.docx | DOCX document | |
| SOLICITATION W911N224Q0056.pdf | ||
| 4_Safety Review - Vacuum Insulated Panels.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
C
D
A
B
C
D
LEAD-FP-5131 A
REVDRAWING NO.
C
SIZE
0NDM7
DAI
MIRCS VACUUM INSULATED PANELS
SHEETSCALE N/A WEIGHT N/A
TITLE
CHAMBERSBURG, PA 17201
LETTERKENNY ARMY DEPOT
APPLICATION
USED ONNEXT ASSY
MATERIAL
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES:
TOLERANCES ARE:
DO NOT SCALE DRAWING
DECIMALS
.X±.06
.XX±.03
ANGLE
±1°
.XXX±.015
FRACTIONS
±1/32
REVISION HISTORY
ZONE REV DESCRIPTION DATE APPROVED
- INITIAL PRODUCTION RELEASE - -
A ADDED DASH NUMBERS FOR ALL PANELS 07 JUL 23 MJD
MIRCS
VIP
OF 11DATE
LEAD APRVD
CHECKED
DRAWN
07 JUL 23
NOT REQUIRED
MJ DESTEFANO
THIRD ANGLE
PRODUCTION ENGINEERING
DIVISION
SAFETY
PROJECTION
DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE. DISTRIBUTION IS UNLIMITED.
MJ DESTEFANO
SP DULEY
NOTES:
1. INTERPRET DRAWING IN ACCORDANCE WITH ASME Y14.100-2013 AND ASME Y14.5-2009.
2. THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.020 BTU-INCH/FT2-HR-F PER ASTM C518.
3. PANEL PREFORMANCE DEGRADATION SHALL NOT EXCEED 2.8% PER YEAR.
4. VIP SHALL BE RATED FOR TEMPATURE EXPOSURE OF 200 DEGREES F MINIMUM.
PANEL SIZE TABLE
PART NUMBER A (LENGTH) B (WIDTH) C (THICKNESS)
LEAD-FP-5131-A 23 5/8 35 1/8 0.75
LEAD-FP-5131-B 21 3/8 35 1/8 0.75
LEAD-FP-5131-C 26 3/8 22 5/8 0.75
LEAD-FP-5131-D 8 7/8 12 0.63
LEAD-FP-5131-E 8 7/8 29 1/2 0.63
LEAD-FP-5131-F 17 1/4 24 1/2 0.63
LEAD-FP-5131-G 26 28 3/8 0.63
LEAD-FP-5131-H 21 1/2 21 1/2 0.75
LEAD-FP-5131-J 21 1/2 45 1/2 0.75
LEAD-FP-5131-K 13 5/8 12 3/4 0.75
LEAD-FP-5131-L 14 28 0.63
LEAD-FP-5131-M 14 13 0.63
LEAD-FP-5131-N 24 1/2 29 1/2 0.75
LEAD-FP-5131-P 19 1/8 27 1/2 0.63
LEAD-FP-5131-Q 19 1/8 39 3/8 0.50
A (LEGNTH) +/- 0.125
B (WIDTH) +/- 0.125 C (THICKNESS) +/- 0.062