This is an Air Force construction drawing for Middle Georgia State University's Thomas Hall facility. The drawing (Drawing No. 98752) depicts a building layout and renovation plan dated December 2024, prepared by Ronnie Fields and Thomas Hall of Middle Georgia State University. The document shows architectural modifications for multiple rooms and spaces including a Security Office, Storage, Conference/Multipurpose Room, Break Room, and Collaboration Room, with detailed specifications for wall installations, door placements, and window modifications. Key construction notes indicate that all new walls extend floor to ceiling at approximately 11 feet 6 inches in height, with specifications for installing new sliding doors with service windows, cross-wall vents in ceilings, and day-gate installations in existing hallways. The drawing references aluminum extruded frame windows with single-pane sliding transactions and bullet-resistant Lexan glazing similar to model 600 specifications with paint matching existing doors. The document includes tolerance specifications for dimensions in inches and fractions, material specifications, and includes references to various construction details marked with triangular symbols throughout the layout. This appears to be a technical construction document rather than a solicitation or contract opportunity document.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Security OfficeStorage
Conference / Multipurpose Room
109 10
A106
A115
Security Office
Storage
Conference / Multipurpose
Room
Break Room / Multipurpose
Room
Collab Room
A106
Collab Room
A
B
C
D
8 7 6 5
IDENTIFYING NO.
PARTS LISTQUANTITY REQUIRED PER DASH NO.
ANGLES
1 DEG
NOMENCLATURE
DIMENSIONS ARE IN INCHES - TOLERANCES ON:
UNLESS OTHERWISE SPECIFIED
.xx±
.xxx±
FRACTIONS
+ 1/16
SYM
DECIMALS
.06 .062 -
AIR FORCE RELEASE
AIR FORCE AUTHENTICATION
ENG
CHK
CODE IDENT
DR
SW
MATERIAL/ SPECIFICATION
U.S. AIR FORCE
DRAWING NO.
98752
AIR FORCE CODE IDENT NO.
D
SIZE
TITLE
UNIT WT ZONE FIND NO.
B
LTR
3 2
APPROVED
REVISIONS
DESCRIPTION DATE
OFSHEET
A
C
D
ENGINEERING DRAWING LAYOUT D
USED ON
*** COMPUTER GENERATED ***
CODE IDENT NO. APPLICATION
CURRENT NEXT ASSEMBLY
FILE --
SCALE
RONNIE FIELDS
THOMAS HALL
STATE UNIVERSITY
MIDDLE GEORGIADEC 2024
\BUILDINGS\0MGSU\2024MGSU
1 1NOTED X
AutoCAD SHX Text
INSTALL 36" DOOR
AutoCAD SHX Text INSTALL 4" THICK WALLS, COVE BASE, PAINT (typ)
AutoCAD SHX Text
INSTALL DOOR
AutoCAD SHX Text
INSTALL NEW SLIDING 36" SECURE SERVICE WINDOW
AutoCAD SHX Text ~21'-7 1/2"
AutoCAD SHX Text ~33'-1"
AutoCAD SHX Text
EXISTING WALL
AutoCAD SHX Text
EXISTING DOOR
AutoCAD SHX Text 11'-3"
AutoCAD SHX Text
EXISTING WINDOWS
AutoCAD SHX Text 12'-4"
AutoCAD SHX Text 7'
AutoCAD SHX Text
INSTALL MIN. (2) ADDITIONAL SPRINKLERS
AutoCAD SHX Text
RETURN DUCT
AutoCAD SHX Text
LIGHT FIXTURE
AutoCAD SHX Text
EXISTING (6) SPRINKLERS
AutoCAD SHX Text 5'
AutoCAD SHX Text 3'
AutoCAD SHX Text
RETURN DUCT
AutoCAD SHX Text
SUPP DUCT
AutoCAD SHX Text
SUPP DUCT
AutoCAD SHX Text
SUPP DUCT
AutoCAD SHX Text
SUPP DUCT
AutoCAD SHX Text
INSTALL 6" MIN. CROSS WALL VENT IN CEILING
AutoCAD SHX Text
INSTALL 6" MIN. CROSS WALL VENT IN CEILING
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text M
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
COMM
AutoCAD SHX Text
ELEC
AutoCAD SHX Text window
AutoCAD SHX Text
140 WORK STATIONS
AutoCAD SHX Text window
AutoCAD SHX Text
MULTI
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text Badge
AutoCAD SHX Text Badge
AutoCAD SHX Text Badge
AutoCAD SHX Text Badge
AutoCAD SHX Text Badge
AutoCAD SHX Text Badge
AutoCAD SHX Text glass wall
AutoCAD SHX Text
WORK AREAS
AutoCAD SHX Text 17'-4 1/4"
AutoCAD SHX Text
LIGHT FIXTURE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
COMM
AutoCAD SHX Text Badge
AutoCAD SHX Text
INSTALL DAY GATE IN EXISTING HALLWAY
AutoCAD SHX Text ~8'-6"
AutoCAD SHX Text 4'-7 1/8"
AutoCAD SHX Text 4'-4 7/16"
AutoCAD SHX Text 4'-11 3/16"
AutoCAD SHX Text 2'-8 5/8"
AutoCAD SHX Text ADD ADDITIONAL AND/OR RELOCATE ALL CEILING-MOUNTED DEVICES IN THIS AREA AS REQUIRED
AutoCAD SHX Text
INSTALL 6" MIN. CROSS WALL VENT IN CEILING
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text REPLACE ONE URINAL W/ TOILET IN EACH OF THE TWO MENS RESTROOMS. EXTEND PARTITIONS AND ADD DOOR PER EACH REPLACEMENT.
AutoCAD SHX Text
MULTI
AutoCAD SHX Text glass wall
AutoCAD SHX Text
MOVE BOTH LIGHT FIXTURES PLAN NORTH 6" TO AVOID NEW WALL
AutoCAD SHX Text
MOVE LIGHT SWITCH TO OTHER SIDE OF DOORWAY
AutoCAD SHX Text
AutoCAD SHX Text E01
AutoCAD SHX Text e01
AutoCAD SHX Text
MIDDLE GA STATE UNIVERSITY - CONSTRUCTION NEEDS
AutoCAD SHX Text
SCALE: " = 1'-0"14" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text E01
AutoCAD SHX Text e01
AutoCAD SHX Text
MIDDLE GA STATE UNIVERSITY - KEY PLAN
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"
AutoCAD SHX Text
SCALE: " = 1'-0"316" = 1'-0"
AutoCAD SHX Text
SCALE: " = 1'-0"14" = 1'-0"
AutoCAD SHX Text
NOTE: ALL NEW WALLS ARE FLOOR TO CEILING. FLOOR TO CEILING HEIGHT ~ 11'-6"
AutoCAD SHX Text
NOTE: ADDED 3 APRIL 2026
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
3 APRIL 2026
AutoCAD SHX Text A
AutoCAD SHX Text HOLLOW CORE WOOD DOOR, WINDOWLESS, NON-FIRE-RATED, WOOD FRAME, KEYED ENTRY-SIDE INTERIOR LOCKSET, PAINT TO MATCH EXISTING DOORS
AutoCAD SHX Text B
AutoCAD SHX Text SOLID CORE WOOD DOOR, WINDOWLESS, NON-FIRE-RATED, METAL FRAME, KEYED ENTRY-SIDE INTERIOR LOCKSET, PAINT TO MATCH EXISTING DOORS
AutoCAD SHX Text C
AutoCAD SHX Text SOLID CORE METAL DOOR, WINDOWLESS, NON-FIRE-RATED, METAL FRAME, ENTRY-SIDE PUSHBAR, PAINT TO MATCH EXISTING DOORS, COORDINATE WITH ALARM/ACCESS CONTROL CONTRACTOR FOR FRAME WIRING AND PATHWAYS.
AutoCAD SHX Text M
AutoCAD SHX Text ALUMINUM EXTRUDED FRAME, SINGLE PANE SLIDING TRANSACTION WINDOW, " LEVEL 1 BULLET-RESISTANT 34" LEVEL 1 BULLET-RESISTANT LEXAN GLAZING, SIMILAR TO MODEL 600 SECURITY BY READY ACCESS. PAINT TO MATCH EXISTING DOORS.
AutoCAD SHX Text
AutoCAD SHX Text
26 JUN 2026
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text